P03 Sole Source BNOE 503-21-102.pdf

PDF 316 KB Posted

Attached to
Z1DA--NRM| 503-21-102 Correct FCA Electrical Deficiencies Phase 1 (VA-26-00004932)
Solicitation number
36C24426R0017
Issued by

About this file

This document is a Sole Source listing for the Department of Veterans Affairs (VA) Medical Center project #503-21-102, focused on Correct FCA Electrical Deficiencies Phase 1. The document specifies seven mandatory sole source manufacturers that contractors must use without exception, including SALTO for wireless electronic door hardware, Honeywell Notifier for fire alarm systems, Bettwy Systems for fire alarm installation, Trane Tracer Ensemble for BAS controls, Wattstopper DLM for lighting control, Avigilon for security cameras, and Inpro Contego for space signage. Additionally, the document lists eleven specific brand name or equal products required for the project, such as DAC Industries panic bar kit, various Daikin HVAC equipment, Zoeller pump, Watts valve, Schneider Electric power meter, EATON switchgear, ASCO power meter, Garland metal roof system, and Procore Technologies, each referenced to specific drawings or specifications.

View the file

Other files

File Type Posted
36C24426R0017 0002.docx DOCX document
RFI 2.6.2026.docx DOCX document
Revised_Statement of Work 503-21-102.pdf PDF
36C24426R0017 0001.docx DOCX document
FCA Electrical Sign In Sheet_1.22.26.pdf PDF
NewSwitchGearBuildingElevationsDetails_Revision1_02032026.pdf PDF
Pre-bid Site Visit Meeting Location.png PNG image
503-21-102 FCA Electrical Construction Drawings.pdf PDF
503-21-102 CD Specifications_Revised 7-29-25.pdf PDF
36C24426R0017.docx DOCX document
P03 36C244-26-AP-0018 Inpro Contego Signage signed _Redacted.pdf PDF
Pre-Bid Site Visit Meeting Location.pdf PDF
P03 36C244-26-AP-0018 Avigilon Camera signed Redacted.pdf PDF
Statement of Work 503-21-102.pdf PDF
S02 36C24426R0017 Liquidated Damages signed.pdf PDF
EXHIBIT C - Past Performance Questionnaire.pdf PDF
503-21-102 Pre-Bid RFI .docx DOCX document
P03 36C244-26-AP-0018 Honeywell Notifier signed_Redacted.pdf PDF
01-EP-501.pdf PDF
072113 Thermal Insulation 09192025.pdf PDF
P03 36C244-26-AP-0018 02_Salto Door signed_Redacted.pdf PDF
P03 36C244-26-AP-0018 Bettwy Systems signed Redacted.pdf PDF
P03 36C244-26-AP-0018 Wattstopper DLM signed Redacted.pdf PDF
P03 36C244-26-AP-0018_Trane Tracer Ensemble signed Redacted.pdf PDF
PA 20260077 01.09.2026.pdf PDF
EXHIBIT D - Price Proposal Breakdown.pdf PDF
Exhibit B - Subcontractor Information and Consent Form.pdf PDF
Exhibit A - Experience.pdf PDF
076000 Flashing.pdf PDF
Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

503-21-102

SOLE SOURCE

In accordance with VAAR clause 852.236-90, RESTRICTION ON SUBMISSION AND USE

OF EQUAL PRODUCTS (NOV 1986)

List of sole source manufacturers and referenced locations for Altoona James E. VanZandt DEPARTMENT OF VETERANS AFFAIRS VA Medical Center project #503-21-102 Correct FCA Electrical Deficiencies Phase 1. Contractor is required to use these sole source items without exception. Justifications are included in the bid package.

1. Wireless Electronic Door Hardware shall be “SALTO”

2. Fire alarm system shall be “Honeywell Notifier”.

3. Fire alarm Installer shall be “Bettwy Systems”

4. BAS controls shall be “Trane Tracer Ensemble”

5. Lighting control system shall be “Wattstopper DLM”

6. Security cameras shall be “Avigilon”

7. Space Signage shall be “Inpro Contego”

Notwithstanding the “Material and Workmanship” clause of this contract, FAR 52.236-5(a), nor any other contractual provision, “equal” products will not be considered by the Department of Veterans Affairs and may not be used.

BRAND NAME OR EQUAL

Per FAR clause 52.211-6 – the following are basis of design and are required to be brand name or equal:

• DAC INDUSTRIES, 6035 DAC STANDARD KIT WITH DETEX PANIC BAR –

Drawing 01-AE101

• Daikin FXMQ54 – Drawing X-M-001

• Daikin RXYQ120 – Drawing X-M-001

• Zoeller I161 – Drawing X-M-001

• Watts FD-320-Y – Drawing X-M-001

• Daikin FTX12 / RX12 – Drawing X-M-001

• Schneider Electric PM8000 – Drawing 08-EL/P-101

• EATON MEF Switchgear – Drawing 08-EP-502

• ASCO 7000 Series with ASCO 5210 digital power meter – Drawing 01-EP-501

• The Garland Company, Inc.R-Mer Span Structural Standing Seam Metal Roof

System – Specification 07 41 13-6

• Procore Technologies – Specification 01 31 23-2 https://www.acquisition.gov/far/current/html/52_233_240.html#wp1113390