P02 Drawings.pdf
PDF 3 MB Posted
- Attached to
- Y1DA--630A4-26-401 MRI AHU Modification
- Solicitation number
- 36C24226R0060
About this file
This document comprises architectural drawings for the relocation of an MRI system at a Veterans Affairs facility located at 800 Poly Place, Brooklyn, NY (Building 15). The project is issued for bid by the Office of Construction and Facilities Management under project number 630A4-14-450 (drawing number 630A4-CSI-109), with an issue date of March 13, 2020.
The first page presents a site plan identifying the main hospital building and surrounding structures, with the 30-ton MRI chiller location marked at the rear entrance near the outpatient clinic. The second page contains detailed basement-level safety/egress and infection control plan drawings with extensive technical notes, abbreviations, and construction specifications. The drawings indicate two chiller location options (Option 1 and Option 2) and show the MRI-AHU (air handling unit) placement. The document includes comprehensive infection control risk assessment matrices for construction and renovation activities, organized by contamination risk levels (Type I through Type IV), along with detailed descriptions of required infection control precautions for various construction phases. The consultant architect of record is Michael Avramides Architect (New York, NY), with design consultant listed as Kform Design Architect LLC (New Jersey). Multiple approval signatures are required from the Project Director, Associate Project Director, Chief Engineer, Safety Manager, and other facility officials.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VHANYNSituJ Polygon
VHANYNSituJ Callout 30 TON MRI Chiller
ZONE I
ZONE I
ZONE II
ZONE II
ZONE III
ZONE IVZONE IV ZONE III ZONE IV
ZONE III
ZONE II
ZONE I
SAFETY/EGRESS - BASEMENT PART PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
ISSUE FOR BIDOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Architectural Design Consultant:
13 MAR 2020Revisions: Date:
630A4-14-450
(630A4-CSI-109)
800 POLY PLACE, BROOKLYN, NY
RELOCATE MRI
THINKFORM DESIGN ARCHITECT LLC
38 EAST BROAD STREET
HOPEWELL, NJ 08525
T:855.821.0274 F:609.644.4397
MICHAEL AVRAMIDES ARCHITECT
319 E 50TH STREET, STUDIO E
NEW YORK, NY 10022
T:917.855.8111
Approved: Project Director
Approved: Assoc Project Director
Approved: Chief Engineer
Approved: Safety Manager
Approved: NAL
Approved: PCC/Service Director
19-01-BK
KEY MAP - BLDG 15 : BASEMENT LEVEL
MC TB
Option 2 Chiller Location
Option 1 Chiller Location
MRI - AHU
AutoCAD SHX Text
TRAVEL DISTANCE BTWN EXITS: 182'-9"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
CB-8
AutoCAD SHX Text
STAIR # 1
AutoCAD SHX Text
ST-1
AutoCAD SHX Text
FIRE PUMP, SUMP PUMP
AutoCAD SHX Text
& DOMESTIC WATER
AutoCAD SHX Text B-624
AutoCAD SHX Text
SILVER
AutoCAD SHX Text
RECOVERY
AutoCAD SHX Text
CB-621
AutoCAD SHX Text
TELE
AutoCAD SHX Text C-620
AutoCAD SHX Text
ELEC
AutoCAD SHX Text B-619
AutoCAD SHX Text
SIGNAL
AutoCAD SHX Text B-618
AutoCAD SHX Text
LIBRARY
AutoCAD SHX Text B-616C
AutoCAD SHX Text
RECEPTION
AutoCAD SHX Text B-616B
AutoCAD SHX Text
WAITING
AutoCAD SHX Text B-616A
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
CB-9
AutoCAD SHX Text
STAIR # 2
AutoCAD SHX Text
ST-2
AutoCAD SHX Text 4.8
AutoCAD SHX Text 3.2
AutoCAD SHX Text
TRAVEL DISTANCE TO EXIT: 134'-6"
AutoCAD SHX Text
TRAVEL DISTANCE TO EXIT: 130'-7"
AutoCAD SHX Text
UNFINISHED SPACE
AutoCAD SHX Text
UNFINISHED SPACE
AutoCAD SHX Text
COMMON PATH OF TRAVEL: 81'-0"
AutoCAD SHX Text
FE CAB #1 NFPA 10
AutoCAD SHX Text
FE CAB #2 NFPA 10
AutoCAD SHX Text
FE CAB #3 NFPA 10
AutoCAD SHX Text
MRI SAFETY ZONE IV - RESTRICTED POTENTIALLY HAZARDOUS AREA
AutoCAD SHX Text
MRI SAFETY ZONE III - RESTRICTED ACCESS
AutoCAD SHX Text
MRI SAFETY ZONE II - CONTROLLED ACCESS
AutoCAD SHX Text
MRI SAFETY ZONE I - ACCESSIBLE BY GENERAL PUBLIC
AutoCAD SHX Text A LABEL CLASS A DOOR CLASS A DOOR A/C AIR CONDITION AIR CONDITION A/E ARCHITECT/ENGINEER ARCHITECT/ENGINEER ABV ABOVE ABOVE ACT ACOUSTICAL CEILING TILE ACOUSTICAL CEILING TILE AD AREA DRAIN AREA DRAIN ADH ADHESIVE ADHESIVE ADJ ADJACENT ADJACENT ADMIN ADMINISTRATION ADMINISTRATION AFC ABOVE FINISHED COUNTER ABOVE FINISHED COUNTER AFF ABOVE FINISHED FLOOR ABOVE FINISHED FLOOR AHU AIR HANDLING UNIT AIR HANDLING UNIT ALT ALTERNATE ALTERNATE ALUM ALUMINUM ALUMINUM APPROX APPROXIMATE APPROXIMATE ARCH ARCHITECT ARCHITECT ASB ASBESTOS ASBESTOS ASPH ASPHALT ASPHALT ASSN ASSOCIATION ASSOCIATION AUTO AUTOMATIC AUTOMATIC AUX AUXILIARY AUXILIARY BAT BATTEN BATTEN BD BOARD BOARD BEV BEVEL BEVEL BKG BACKING BACKING BLDG BUILDING BUILDING BOT BOTTOM BOTTOM BTWN BETWEEN BETWEEN C TO C CENTER TO CENTER CENTER TO CENTER CAB CABINET CABINET CONC CONCRETE CONCRETE CIR CIRCLE CIRCLE CL CENTER LINE CENTER LINE CLDG CLADDING CLADDING CLG CEILING CEILING CLG HT CEILING HEIGHT CEILING HEIGHT CLR CLEAR CLEAR CM CENTIMETER CENTIMETER CMU CONCRETE MASONRY UNIT CONCRETE MASONRY UNIT CNTR COUNTER COUNTER COL COLUMN COLUMN CONC FLR CONCRETE FLOOR CONCRETE FLOOR CONSTR CONSTRUCTION CONSTRUCTION CONT CONTINUE CONTINUE COORD COORDINATE COORDINATE CPT CARPET CARPET CSWK CASEWORK CASEWORK CT CERAMIC TILE CERAMIC TILE CTRL CONTROL CONTROL DAT DATUM DATUM DC DIRECT CURRENT DIRECT CURRENT DEG DEGREE DEGREE DEL DELETE DELETE DEMO DEMOLITION DEMOLITION DEPT DEPARTMENT DEPARTMENT DTL DETAIL DETAIL DIFF DIFFERENCE DIFFERENCE DIM DIMENSION DIMENSION DIR DIRECTION DIRECTION DR DOOR, OR DRAIN DOOR, OR DRAIN DR OPNG DOOR OPENING DOOR OPENING E.J. EXPANSION JOINT EXPANSION JOINT EL ELEVATION ELEVATION ELEC ELECTRIC ELECTRIC ELEV ELEVATOR ELEVATOR EMER EMERGENCY EMERGENCY ENGR ENGINEER ENGINEER EQ EQUAL EQUAL EQUIP EQUIPMENT EQUIPMENT EQUIV EQUIVALENT EQUIVALENT ESP ESPECIALLY ESPECIALLY EXIST EXISTING EXISTING FA FIRE ALARM FIRE ALARM FAS FASCIA FASCIA FD FLOOR DRAIN FLOOR DRAIN FE FIRE EXTINGUISHER FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FIRE EXTINGUISHER CABINET FIN FLR FINISH FLOOR FINISH FLOOR FIXT FIXTURE FIXTURE FLR FLOOR FLOOR FP FIRE PROTECTION OR FIREPROOF FIRE PROTECTION OR FIREPROOF FRT FIRE RETARDANT TREATED FIRE RETARDANT TREATED FRZ FREEZER FREEZER FT FEET OR FOOT FEET OR FOOT FURN FURNISH OR FURNITURE FURNISH OR FURNITURE GA GAGE OR GYPSUM ASSOCIATION GAGE OR GYPSUM ASSOCIATION GAL GALLON GALLON GALV GALVANIC OR GALVANIZED GALVANIC OR GALVANIZED GB GRAB BAR GRAB BAR GC GENERAL CONTRACTOR GENERAL CONTRACTOR GEN GENERAL OR GENERATOR GENERAL OR GENERATOR GL GLASS GLASS GLU LAM GLUED LAMINATED WOOD GLUED LAMINATED WOOD GT GROUT GROUT GYP GYPSUM GYPSUM GYP BD GYPSUM BOARD GYPSUM BOARD HB HOSE BIBB HOSE BIBB HC HOLLOW CORE HOLLOW CORE HDWD HARDWOOD HARDWOOD HM HOLLOW METAL HOLLOW METAL HT HEIGHT HEIGHT HVAC HEATING, VENTILATING, HEATING, VENTILATING, AND AIR CONDITIONING ID IDENTIFICATION IDENTIFICATION ILLUM ILLUMINATION ILLUMINATION INCL INCLUDED INCLUDED INFO INFORMATION INFORMATION INSUL INSULATION INSULATION INT INTERIOR INTERIOR JAN JANITOR JANITOR J-BOX JUNCTION BOX JUNCTION BOX LAB LABORATORY LABORATORY LAM LAMINATE LAMINATE LAV LAVATORY LAVATORY LDR LEADER LEADER LED LIGHT EMITTING DIODE LIGHT EMITTING DIODE LT LIGHT LIGHT LVD LOUVERED LOUVERED LVR LOUVER LOUVER LYR LAYER LAYER
AutoCAD SHX Text M METER METER MAINT MAINTENANCE MAINTENANCE MATL MATERIAL MATERIAL MAX MAXIMUM MAXIMUM MECH MECHANICAL MECHANICAL MEMO MEMORANDUM MEMORANDUM MEZZ MEZZANINE MEZZANINE MID MIDDLE MIDDLE MIRR MIRROR MIRROR MISC MISCELLANEOUS MISCELLANEOUS MLDG MOLDING (MOULDING) MOLDING (MOULDING) MLWK MILLWORK MILLWORK MO MASONRY OPENING MASONRY OPENING MTL METAL METAL MULL MULLION MULLION NA NOT APPLICABLE NOT APPLICABLE NAT NATURAL NATURAL NIC NOT IN CONTRACT NOT IN CONTRACT NO NUMBER NUMBER NOM NOMINAL NOMINAL NUM NUMERAL NUMERAL OC ON CENTER ON CENTER OCC OCCUPY OCCUPY OFF OFFICE OFFICE OPNG OPENING OPENING OPP OPPOSITE OPPOSITE OSHA OCCUPATIONAL SAFETY AND OCCUPATIONAL SAFETY AND HEALTH ADMINSTRATION OZ OUNCE OUNCE PART PARTIAL PARTIAL PAT PATTERN PATTERN PEN PENETRATE PENETRATE PERF PERFORATED PERFORATED PERP PERPENDICULAR PERPENDICULAR PLAS PLASTER OR PLASTIC PLASTER OR PLASTIC PLBG PLUMBING PLUMBING PLYWD PLYWOOD PLYWOOD PNL PANEL PANEL PRCST PRECAST PRECAST PREFAB PREFABRICATE PREFABRICATE PRELIM PRELIMINARY PRELIMINARY PREP PREPARATION PREPARATION PREV PREVIOUS PREVIOUS PROP PROPERTY PROPERTY PTD PAINTED PAINTED PVC POLYVINYL CHLORIDE (PLASTIC) POLYVINYL CHLORIDE (PLASTIC) QA QUALITY ASSURANCE QUALITY ASSURANCE QC QUALITY CONTROL QUALITY CONTROL QT QUARRY TILE QUARRY TILE QTB QUARRY TILE BASE QUARRY TILE BASE QTR QUARTER QUARTER QTY QUANTITY QUANTITY R RADIUS OR RISER RADIUS OR RISER RAD RADIATOR RADIATOR RB RESILIENT BASE OR RUBBER RESILIENT BASE OR RUBBER BASE RBR RUBBER RUBBER RCP REFLECTED CEILING PLAN REFLECTED CEILING PLAN RCVR RECEIVER RECEIVER RD ROAD OR ROOF DRAIN ROAD OR ROOF DRAIN REC RECESSED RECESSED RECT RECTANGLE RECTANGLE REF REFERENCE OR REFRIGERATOR REFERENCE OR REFRIGERATOR REINF REINFORCE REINFORCE REQ REQUIRE REQUIRE REQD REQUIRED REQUIRED RESIL RESILIENT RESILIENT RET RETURN RETURN REV REVISION REVISION RM ROOM ROOM RND ROUND ROUND RO ROUGH OPENING ROUGH OPENING SALV SALVAGE SALVAGE SBSTR SUBSTRATE SUBSTRATE SCHED SCHEDULE SCHEDULE SCHEM SCHEMATIC SCHEMATIC SECT SECTION SECTION SEP SEPARATE SEPARATE SF SQUARE FOOT (FEET) SQUARE FOOT (FEET) SLNT SEALANT SEALANT SMK SMOKE SMOKE SPEC SPECIFICATION SPECIFICATION SPKLR SPRINKLER SPRINKLER SPLY SUPPLY SUPPLY SQ SQUARE SQUARE SS STAINLESS STEEL STAINLESS STEEL STD STANDARD STANDARD STOR STORAGE STORAGE STR STRINGERS STRINGERS STRUCT STRUCTURAL STRUCTURAL SURF SURFACE SURFACE SUSP SUSPEND SUSPEND SYS SYSTEM SYSTEM T&G TONGUE AND GROOVE TONGUE AND GROOVE TECH TECHNICAL TECHNICAL TEL TELEPHONE TELEPHONE TEMP TEMPERATURE OR TEMPORARY TEMPERATURE OR TEMPORARY THK THICKNESS THICKNESS THRU THROUGH THROUGH TMPD TEMPERED TEMPERED TO TOP OF ___ TOP OF ___ TRANS TRANSOM TRANSOM TRTD TREATED TREATED TYP TYPICAL TYPICAL U HEAT TRANSFER COEFFICIENT HEAT TRANSFER COEFFICIENT UPS UNINTERRUPTIBLE POWER UNINTERRUPTIBLE POWER SUPPLY UTIL UTILITY UTILITY UV ULTRAVIOLET ULTRAVIOLET VAC VACUUM VACUUM VAR VARIES VARIES VCT VINYL COMPOSITION TILE VINYL COMPOSITION TILE VENT VENTILATION VENTILATION VERT VERTICAL VERTICAL VEST VESTIBULE VESTIBULE VIF VERIFY IN FIELD VERIFY IN FIELD VOL VOLUME VOLUME W/ WITH WITH W/O WITHOUT WITHOUT WD WOOD WOOD WSCT WAINSCOT WAINSCOT WT WEIGHT WEIGHT
AutoCAD SHX Text
ABBREVIATIONS
AutoCAD SHX Text
INFECTION CONTROL RISK ASSESSMENT
AutoCAD SHX Text A. 1. PRIMARY APPLICABLE CODES AND STANDARDS - EXISTING BUILDING / RECONSTRUCTION 1. PRIMARY APPLICABLE CODES AND STANDARDS - EXISTING BUILDING / RECONSTRUCTION THE DEPARTMENT OF VETERANS AFFAIRS HAS ADOPTED THE LATEST EDITION OF THE FOLLOWING CODES AND STANDARDS AS A MINIMUM FOR ALL PROJECTS PERFORMED IN THE MODERNIZATION, ALTERATION, ADDITION OR IMPROVEMENT OF ITS REAL PROPERTY AND THE CONSTRUCTION OF NEW STRUCTURE. a. NFPA 101 LIFE SAFETY CODE, 2018 EDITION b. NFPA NATIONAL FIRE CODES (WITH THE EXCEPTION OF NFPA 5000 AND NFPA 900) c. NATIONAL ELECTRIC CODE (NEC) d. INTERNATIONAL PLUMBING CODE (IPC) e. ASME BOILER AND PRESSURE VESSEL CODE f. ASME CODE FOR PRESSURE PIPING g. ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABAAS) INCLUDING VA SUPPLEMENT, BARRIER FREE DESIGN GUIDE (PG-18-13) h. ENERGY POLICY ACT (EPAct) i. VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE TECHNICAL INFORMATION LIBRARY (TIL) j. VA MENTAL HEALTH DESIGN GUIDE k. INTERNATIONAL BUILDING CODE (IBC) - ONLY WHEN SPECIFICALLY REFERENCE IN VA DESIGN DOCUMENTS l. OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS 2. THE CONSTRUCTION CLASSIFICATION IS TYPE II (222). THE MINIMUM FIRE RATING FOR ALL LOAD-BEARING STRUCTURAL ELEMENTS IS 2HRS. IF DURING CONSTRUCTION, ANY DAMAGE TO EXISTING FIREPROOFING IS OBSERVED OR IF DISCOVERED THAT ANY FIRE PROTECTION IS MISSING, THE CONTRACTOR SHALL REPAIR TO MAINTAIN FULL PROTECTION. 3. THE NEW MRI AREA OCCUPIES 7,020 SQ FT OF THE BASEMENT LEVEL IN BROOKLYN VAMC BUILDING 15.
AutoCAD SHX Text
CODE NOTES
AutoCAD SHX Text
TRAVEL DISTANCE
AutoCAD SHX Text 0-G002
AutoCAD SHX Text
ABBREVIATIONS, CODE NOTES AND FIRE SAFETY/ EGRESS
AutoCAD SHX Text
AutoCAD SHX Text G002
AutoCAD SHX Text 1/8" = 1'-0"
AutoCAD SHX Text
2 HOUR FIRE RESISTANCE RATED FIRE BARRIER
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
STAIR # 1
AutoCAD SHX Text
ST-1
AutoCAD SHX Text
MECH
AutoCAD SHX Text B-604
AutoCAD SHX Text NFPA 101 REVIEW B. CHAPTER 20 NEW AMBULATORY HEALTH CARE OCCUPANCIES CHAPTER 20 NEW AMBULATORY HEALTH CARE OCCUPANCIES 1. (20.1.1.1.1) THE REQUIREMENTS OF THIS CHAPTER SHALL APPLY TO NEW BUILDINGS OR PORTIONS THEREOF USED AS AMBULATORY HEALTH CARE OCCUPANCIES. 2. (20.1.1.4.4) CONSTRUCTION - SEE 4.6.10: BUILDINGS, OR PORTIONS OF BUILDINGS, SHALL BE PERMITTED TO BE OCCUPIED DURING CONSTRUCTION ONLY WHERE REQUIRED MEANS OF EGRESS AND REQUIRED FIRE PROTECTION FEATURES ARE IN PLACE AND CONTINUOUSLY MAINTAINED FOR THE PORTION OCCUPIED OR WHERE ALTERNATIVE LIFE SAFETY MEASURES ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION ARE IN PLACE. 3. (20.1.7) THE OCCUPANT LOAD SHALL BE DETERMINED ON THE BASIS OF OCCUPANT LOAD FACTORS OF TABLE 7.3.1.2: HEALTH CARE USE, AMBULATORY HEALTH CARE; 150 SQ FT/PERSON. 7,020 SF AREA/150 = 47 OCCUPANTS
AutoCAD SHX Text C. MEANS OF EGRESS 1. (20.2.1) ALL MEANS OF EGRESS SHALL COMPLY WITH CHAPTER 7 & THIS CHAPTER. A. 2. (20.2.3.1) CLEAR WIDTH FOR ANY CORRIDOR OR PASSAGEWAY REQUIRED FOR EXIT ACCESS SHALL NOT BE LESS THAN 44 INCHES. 3. (20.2.3.4) DOOR IN THE MEANS OF EGRESS FROM DIAGNOSTIC OR TREATMENT AREAS SHALL PROVIDE A CLEAR WIDTH OF NOT LESS THAN 32 INCHES. 4. (20.2.5.2.1) DEAD-END CORRIDORS SHALL NOT EXCEED 50 FT. 5. (20.2.6.2.2) THE MAXIMUM TRAVEL DISTANCE BETWEEN ANY POINT IN A ROOM AND AN EXIT SHALL (150 FT PER 20.2.6.2.1) BE PERMITTED TO INCREASE BY 50 FEET IN BLDGS PROTECTED THROUGHOUT BY AN APPROVED AUTOMATIC SPRINKLER SYSTEM. 6. (20.3.6.1) EXIT ACCESS CORRIDORS TO BE 1 HOUR RATED UNLESS (3) WITHIN BUILDINGS PROTECTED THROUGHOUT BY AN APPROVED AUTOMATIC SPRINKLER SYSTEM. D. PROTECTION FROM HAZARDS 1. (20.3.2.1) HAZARDOUS AREAS INCLUDING, BUT NOT LIMITED TO , AREAS USED FOR GENERAL STORAGE, BOILER OR FURNACE ROOMS SHALL BE PROTECTED IN ACCORDANCE WITH SECTION 8.7. 1. (20.3.2.5) AREAS WHERE MEDICAL GAS IS STORED OR ADMINISTERED, AND THE OPERATION, MANAGEMENT, AND MAINTENANCE OF MEDICAL GASES SHALL BE IN ACCORDANCE WITH NFPA 99. E. INTERIOR FINISHES - CHAPTER 20 AND SECTION 10.2 1. (20.3.3.2.1) INTERIOR WALL AND CEILING FINISH MATERIAL COMPLYING WITH SECTION 10.2 SHALL BE CLASS A OR CLASS B IN EXITS AND IN EXIT ACCESS CORRIDORS. 2. (20.3.3.2.2) INTERIOR WALL AND CEILING FINISHES SHALL BE CLASS A, CLASS B OR CLASS C IN ALL AREAS OTHER THAN THOSE SPECIFIED IN 20.3.3.2.1. 3. (20.3.3.3.1) INTERIOR FLOOR FINISH SHALL COMPLY WITH 10.2.
AutoCAD SHX Text F. EXTINGUISHING REQUIREMENTS 1. (20.3.5.3) PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED IN AMBULATORY HEALTH CARE OCCUPANCIES IN ACCORDANCE WITH SECTION 9.9.
AutoCAD SHX Text
CALL NORTH
AutoCAD SHX Text
FE CAB #1 75' RADIUS
AutoCAD SHX Text
1 HOUR FIRE RESISTANCE RATED FIRE BARRIER
AutoCAD SHX Text THE PURPOSE OF INFECTION CONTROL PROCEDURES IS TO MINIMIZE THE POTENTIAL FOR THE SPREAD OF INFECTIONS DUE TO DEGRADED AIR QUALITY, ENVIRONMENTAL CONTAMINATION, OR CONTAMINATION OF WATER. IT IS THE POLICY OF THIS MEDICAL CENTER THAT A SYSTEMATIC APPROACH BASED ON ASSESSMENT AND PLANNING WILL EFFECTIVELY MANAGE THE ISSUE OF TRANSMISSION OF INFECTIOUS DISEASES AND THE AGGRAVATION OF ALLERGIES. THE OVERALL APPROACH RELIES ON PRE-CONSTRUCTION ASSESSMENT, MANAGEMENT OF HVAC SYSTEMS, AND AGGRESSIVE USE OF A VARIETY OF BARRIERS. CONTRACTOR IS TO WORK CLOSELY WITH THE VA FACILITY MANAGEMENT SERVICE CENTER, THE INFECTION CONTROL PROGRAM STAFF AND THE SAFETY AND OCCUPATION HEALTH MANAGER TO HAVE IN PLACE A MONITORING A PROGRAM TO ASSURE RIGOROUS IMPLEMENTATION OF THE REQUIRED MEASURES. REFER TO PROJECT SPECIFICATIONS.
AutoCAD SHX Text
INFECTION CONTROL NOTES
AutoCAD SHX Text A. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE FIELD AND COORDINATE THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE FIELD AND COORDINATE ALL INFECTION CONTROL REQUIREMENTS WITH THE DEMOLITION AND NEW CONSTRUCTION. THE CONTRACTOR SHALL REPORT ALL DISCOVERIES TO THE OWNER'S REPRESENTATIVE FOR RESOLUTION PRIOR TO BEGINNING. B. CONTRACTOR TO INSTALL BARRIERS AND OTHER MEASURES. CONSTRUCTION BARRIER CONTRACTOR TO INSTALL BARRIERS AND OTHER MEASURES. CONSTRUCTION BARRIER DOOR(S) MUST BE SELF-CLOSING. PROVIDE DUST CONTROL AND CONTAINMENT STICKY MATS ON ALL ACCESS DOORS INTO CONSTRUCTION AREA. ANTE-ROOM REQUIRED AT CONSTRUCTION ENTRY. PROVIDE MANOMETER MONITORS FOR ALL CONSTRUCTION BARRIERS.
AutoCAD SHX Text C. CONTRACTOR TO DISPOSE OF MATERIALS BEFORE 8:00AM OR AFTER 4:00PM UNLESS CONTRACTOR TO DISPOSE OF MATERIALS BEFORE 8:00AM OR AFTER 4:00PM UNLESS ARRANGED WITH THE VA TO DISPOSE OF DURING NORMAL HOURS. USE ROUTE AGREED UPON BY ICRA TEAM AND COTR FOR TRANSPORT OF TRANSPORT CONTAINERS THROUGH THE FACILITY. CONTRACTORS CAN ONLY DEVIATE TO NORMAL HOURS WITH THE APPROVAL OF THE INFECTION CONTROL NURSE AND COR DUE TO PARTICULAR CIRCUMSTANCES THAT MAY OBSTRUCT PROGRESS. A CLEAR PLAN WILL HAVE TO BE SUBMITTED AND PRECAUTIONARY INFECTION CONTROL MEASURES IMPLEMENTED. D. CONTRACTOR TO COVER CARTS AND WEAR BOOTIES WHEN DISPOSING MATERIALS. CONTRACTOR TO COVER CARTS AND WEAR BOOTIES WHEN DISPOSING MATERIALS. E. CONTRACTOR TO CHANGE MATS MULTIPLE TIMES A DAY AS NEEDED AND MOP FLOORS CONTRACTOR TO CHANGE MATS MULTIPLE TIMES A DAY AS NEEDED AND MOP FLOORS BEHIND THEM MULTIPLE TIMES A DAY. F. CONTRACTOR TO MAINTAIN CONTINUOUS NEGATIVE AIR PRESSURE WITHIN THE WORK SITE CONTRACTOR TO MAINTAIN CONTINUOUS NEGATIVE AIR PRESSURE WITHIN THE WORK SITE UTILIZING WINDOW EXHAUST FANS STRATEGICALLY LOCATED OR PROVIDE NEGATIVE PRESSURE AIR HEPA UNITS AND EXHAUST TO EXTERIOR OF THE BUILDING. CONTRACTOR TO INCLUDE MONITORING MANOMETER AT ANTEROOM SO THE NEGATIVE PRESSURE CAN BE INSPECTED.
AutoCAD SHX Text
FE CAB #2 75' RADIUS
AutoCAD SHX Text
FE CAB #3 75' RADIUS
VHANYNRomheA Callout Option 1
VHANYNRomheA Callout Option 2
VHANYNRomheA Rectangle
VHANYNRomheA Rectangle
VHANYNRomheA Rectangle
VHANYNRomheA Callout Indoor Unit Location
| Drawings 630A4-26-401 Bk Site Plan MRI Chiller.pdf |
| MRI Drawing 0-G002 |
File details come from the government source that posted it. Updated .