About this file

This is a Stormwater Pollution Prevention Plan (SWPPP) for the Marine Corps Support Facility Blount Island (MCSF-BI) in Jacksonville, Florida, prepared under the Florida Department of Environmental Protection Multi-Sector Generic Permit. The document details the facility's comprehensive strategy for managing stormwater runoff, identifying potential pollutant sources, and implementing best management practices to minimize environmental contamination. The plan covers various industrial activities including vehicle maintenance, wood processing, marine cargo handling, and equipment cleaning across multiple facility sectors, with specific focus on controlling pollutants from areas such as pressure washing, blasting, painting, material storage, engine maintenance, and general yard areas.

The SWPPP includes requirements for quarterly visual assessments, annual comprehensive site compliance evaluations, and analytical monitoring of stormwater discharges for parameters like total suspended solids, chemical oxygen demand, and heavy metals. The document was updated in June 2024 and is valid through January 2026, with provisions for ongoing review and modification. The facility is required to conduct quarterly inspections, maintain detailed records, provide employee training, and implement control measures to prevent stormwater pollution, with specific attention to managing potential contaminants from industrial activities such as vehicle maintenance, wood processing, and marine operations.

View the file

Other files

File Type Posted
N6945025R0003-0007.pdf PDF
JL-1_Labor_Hours_Spreadsheet_0007.xlsx XLSX spreadsheet
J-0200000-17 ELINs_0007.xlsx XLSX spreadsheet
JL-11_N6945025R0003_GPI Responses_0007.pdf PDF
J-0200000-17_ELINs_0006.xlsx XLSX spreadsheet
N6945025R0003-0006.pdf PDF
J-0200000-18 CAT Call Request_0005.pdf PDF
J-1606000-07 Historical Water Work Orders_0005.xlsx XLSX spreadsheet
N6945025R0003_SectionJ_0005.pdf PDF
J-0200000-02-01_N6945025R0003 CBA-2025-439_0005.pdf PDF
N6945025R0003_SectionC_0005.pdf PDF
N6945025R0003-0005.pdf PDF
J-1502000-24 FRCS Roles and Responsiblities_0005.xlsx XLSX spreadsheet
J-0200000-02-02_N6945025R0003 CBA-2025-440_0005.pdf PDF
JL-11_N6945025R0003_GPI Responses_0005.pdf PDF
J-1503010-05 Custodial Inventory_0005.xlsx XLSX spreadsheet
J-1502000 (MCSF-BI) Facility Investment_0005.xlsx XLSX spreadsheet
J-0200000-17 ELINs_0005.xlsx XLSX spreadsheet
J-1502000 Facility Asset Inventories_0005.xlsx XLSX spreadsheet
J-0600000-04 Historical Port Ops Work Orders_0005.xlsx XLSX spreadsheet
N6945025R0003-0004.pdf PDF
N6945025R0003-0003.pdf PDF
JL-9_N6945025R0003_Site_Visit_Brief_0002.pdf PDF
JL-10_N6945025R0003_Site_Visit_Sign-In_Sheets_0002.pdf PDF
N6945025R0003-0002.pdf PDF
JL-7_N6945025R0003_MBOS SITE VISIT ROUTE_0001.pdf PDF
N6945025R0003-0001.pdf PDF
J-1503050-09 (MCSF-BI) Paved Roadways and Lots Map.pdf PDF
JL-6_N6945025R0003_MBOS SITE VISIT Directions.pdf PDF
J-0200000-22 NAVFACINST 11230.1.pdf PDF
JM-2_N6945025R0003_Historical_Small_Business_Utilization.docx DOCX document
J-1502000-07 (MCSF-BI) Compressed Air Systems.pdf PDF
J-0200000-07 Utility Asset Condition Report.xlsx XLSX spreadsheet
J-0600000-03 Maps and Locations.pdf PDF
J-1502000-23 FRCS Cybersecurity Program.pdf PDF
J-1503030-04 (MCSF-BI) Solid Waste and Recycle Containers.pdf PDF
J-1800000-06 Mayport SWPPP.pdf PDF
N6945025R0003_SectionF.pdf PDF
N6945025R0003_2015-4539 (Rev.-28).pdf PDF
JL-7_N6945025R0003_MBOS SITE VISIT ROUTE.pdf PDF
J-1502000-19 NAVSTA Cross Connection Control Program.pdf PDF
N6945025R0003_SectionC.pdf PDF
J-0200000-04 Partnering Agreement.pdf PDF
J-1503050-07 (MCSF-BI) Shoreline Cleanup Map.pdf PDF
J-1502000-08 (MCSF-BI) Crane and Railroad Inventory.pdf PDF
JM-1_N6945025R0003_Corporate_Experience.docx DOCX document
J-0200000-20 USMCmaxUserGuide.docx DOCX document
J-1800000-12 (MCSF-BI) Stormwater System Map.pdf PDF
J-1502000-21 (MCSF-BI) Lighting Systems.pdf PDF
J-1601000-05-01 Service Desk Guide for Reporting Utility System Outages.pdf PDF
Show 40 more

Latest 50 of 116 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Stormwater Pollution Prevention Plan

Facility ID: FLR05D006-005 – Jacksonville, Florida

Marine Corps Support Facility Blount Island

Prepared for:

Marine Corps Support Facility Blount Island Installation Division, Environmental Division 5880 Channel View Boulevard, Building 100 Jacksonville, Florida 32226-3404

Under Contract to:

U.S. Army Corps of Engineers, Mobile District 109 St. Joseph Street Mobile, Alabama 36628

Contract No. W91278-21-D-0059 Task Order No. W9127820F0572

Prepared by:

PHE-BAKER JV2 LLC

77 Upper Rock Circle, Suite 302 Rockville, MD 20850

Updated JUNE 2024

STORMWATER POLLUTION PREVENTION PLAN

JUNE 2024

MCSF-BLOUNT ISLAND, JACKSONVILLE, FLORIDA

INSTALLATION DIVISION

i

This page intentionally left blank.

MCSF-BLOUNT ISLAND, JACKSONVILLE, FLORIDA

i

STORMWATER POLLUTION PREVENTION PLAN CERTIFICATION

I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.

Name: Title:

Signature:

Date:

MCSF-BLOUNT ISLAND, JACKSONVILLE, FLORIDA

ii

NON-STORMWATER DISCHARGE CERTIFICATION

The following statement serves as the certification of non-stormwater discharges at Marine Corps Support Facility Blount Island (MCSF-BI):

"I certify, under penalty of law, that each discharge authorized under the permit has been tested or evaluated for the presence of non-stormwater discharges and that no such non-stormwater discharge is known or has been observed to exist. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the above statement is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations."

Authorized Signatory Date

Printed Name Date

Note: See Section 3.3 for Unauthorized Non-stormwater Discharge documentation.

MCSF-BLOUNT ISLAND, JACKSONVILLE, FLORIDA

iii

SWPPP REVIEW AND/OR MODIFICATIONS

The Stormwater Pollution Prevention Plan (SWPPP) will be modified as often as necessary to be effective in preventing or reducing the discharge of pollutants into stormwater. At a minimum, the SWPPP should be revised when:

• Construction alters the facility’s drainage areas and outfalls

• Changes in design, construction, operation, or maintenance at the facility which may influence the potential for the discharge of pollutants from the facility

• Changes in activities which may result in new pollutants exposed to stormwater or increase the pollutants exposed to stormwater

• Types of materials exposed to stormwater changes

• Spills or releases of a reportable quantity or quantity that could otherwise cause or contribute to significant water quality impairment occur in exposed areas of the facility during the term of the permit

• Control measures of the SWPPP are deemed ineffective in eliminating or significantly minimizing pollutants from pollutant sources at the facility

All changes to the SWPPP will be noted and dated in the SWPPP Review and or Modification Table on page v of this SWPPP.

Pursuant to the requirements of 40 CFR 122.41(j), today’s permit requires permittees to retain all records for a minimum of 3 years from the date of the sampling, examination, or other activity that generated the data.

A copy of this SWPPP will be maintained at the MCSF-BI IDIV’s Environmental Division at 5880 Channel View Boulevard, Jacksonville, Florida. The SWPPP will be readily available to members of the Stormwater Pollution Prevention Team. It will be made immediately accessible to representatives of the FDEP and other regulatory agencies at the time of an on-site inspection or upon request.

Ref: Part IV B.3 Required Modifications and Part IV C Keeping Plans Current, FR 29 Sept 1995, page 51116.

This SWPPP is a “living” document that is modified and updated to always remain current. The plan is amended when there is a change in operations, maintenance, or procedures that have a significant effect on the potential to pollute stormwater runoff. If a best management practice (BMP) proves ineffective, the BMP and SWPPP must be modified. MCSF-BI shall amend this SWPPP whenever there is a change in design, construction, operation, or maintenance that has a significant effect on the potential for the discharge of pollutants to waters of the United States (US), or if the SWPPP proves ineffective in eliminating or significantly minimizing pollutant discharge from facility sources. Amendments may include more effective pollution prevention technology and BMPs if such technology is field proven, and implementation of the technology will significantly reduce the likelihood of stormwater contamination.

SWPPP amendments could also be in response to “required modifications” directed by Florida Department of Environmental Protection (FDEP) or changes in procedures or processes on the installation. If changes occur in response to FDEP required modifications, the certification statement of this SWPPP will be re-signed in accordance with the Florida Multi-Sector Generic Permit (MSGP).

The MSGP requires that a Stormwater Comprehensive Compliance Evaluation (CCE) be conducted annually. The SWPPP is revised as needed based on the results of the CCE.

iv

JUNE 2024

MCSF-BLOUNT ISLAND, JACKSONVILLE, FLORIDA

Based on the results of the evaluation, the description of potential pollutant sources, pollution prevention measures and controls identified shall be revised as appropriate within (2) two weeks of the evaluation and shall provide for implementation of any changes in a timely manner, but in no more than 12 weeks after the evaluation.

v

JUNE 2024

SWPPP REVIEW AND/OR MODIFICATION TABLE

Date of Review/

Modification

Review Status (“No Change” or “Modification”)

Description of Revision or Modification

Printed Name Section or Appendix

9/8/2021 Modification Section 3.4. Outfall 2 and Outfall 5 are no longer considered similar and will be sampled independently.

Patricia Loop 3-15

9/8/2021 Modification Deleted Section 7.4.2.

Updated Table 7.2. Outfall 2 and Outfall 5 are no longer considered similar and will be sampled independently.

Patricia Loop 7-5 and 7-6

9/23/2021 Modification Table 2.3. Updated Building Occupant for Bldg 360, 452, and 458. Changed from MCMC to MBOS

Patricia Loop 2-3

9/23/2021 Modification Updated Table 4-1 (Replace MCMC with NCHB), Tables 4- 10 and 4-18 (Replace MCMC with MBOS), Table 4-24 (replace MCMC with Navy Point)

Patricia Loop 4-1, 4-8, 4- 13, 4-16

12/22/2021 Modification Updated BMP forms to add HM Sheds at bldg. 451 and Woodchipper.

Patricia Loop Appendix H

12/22/2021 Modification Updated Appx E, SWPP Team Members. Added MBOS Env Coordinator Melissa Vergenz

Patricia Loop Appendix E

2/8/2022 Modification Remove “Maintain Stormwater Pollution Prevention Awareness Signage” throughout document. There is no signage in place and has not been in place for years.

Not required. SWPPP training is provided and personnel are aware of requirements

Patricia Loop Section 4.0 (Throughout document)

7/29/2022 Modification Updated date when CCE completed

Patricia Loop 1.2 vi

JUNE 2024

12/6/2022 Modification Add Grounds Contractor and Zone Manager to SWPPT.

Patricia Loop Table 2.3

12/9/2022 Modification Added MSC to list of tenants Patricia Loop 2.4

12/9/2022 Modification Added Facility 930 Lighterage Storage Yard

Patricia Loop Figure 13

12/9/2022 Modification Add painting operations on lighterage yard, Sector RQ activities

Patricia Loop 4.16

12/9/2022 Modification Removed summary of spills and referenced Appendix G for most current list

Patricia Loop 3.2

12/9/2022 Modification Remove outfall 007.

Confirmed line has been capped, there is no discharge at outfall 7.

Patricia Loop Table 2.4

6/24/2024 Modification Updated Facility Point of Contacts

Patricia Loop Table 2.1

6/24/2024 Modification Added Military Sealift Command

Patricia Loop 2.4

6/24/2024 Modification Replaced 2016 water quality data summary with 2024 water quality data summary

Patricia Loop 3.4

6/24/2024 Modification Added Sector heading Patricia Loop Table 3.3

6/24/2024 Modification Updated report release contact and procedure

Patricia Loop 6.1.4

6/24/2024 Modification Added woodchipper for Sector A Added Buildings 452 and 458 for Sector Q

Patricia Loop Table 7.1 vii

JUNE 2024

6/24/2024 Modification Added samples shall be collected as soon as practicable after the first 30 minutes, not to exceed 1 hour.”

Patricia Loop 7.4.1

6/24/2024 Modification Replaced National Response Center with Marine Corps Police Dispatch

Patricia Loop 8.2

6/24/2024 Modification Updated Routine Facility Inspection Form

Patricia Loop Appendix H viii

JUNE 2024

TABLE OF CONTENTS

Stormwater Pollution Prevention Plan Certification ...................................................................... I

Non-Stormwater Discharge Certification ..................................................................................... II

SWPPP Review and/or Modifications ......................................................................................... III

SWPPP Review and/or Modification Table ................................................................................. V

List of Tables ............................................................................................................................. X

List of Appendices ..................................................................................................................... XI

Abbreviations and Acronyms .................................................................................................... XII

1.0 INTRODUCTION ............................................................................................................. 1-1

1.1 Multi-Sector Generic Permit .................................................................................... 1-1

1.2 Environmental Resource Permits for Stormwater Management Systems ................ 1-1

1.3 Stormwater Pollution Prevention Plans Development ............................................. 1-1

2.0 FACILITY DESCRIPTION AND CONTACT INFORMATION ..........................................2-1

2.1 Facility Information .................................................................................................. 2-1

2.2 Contact Information/Responsible Parties ................................................................2-1

2.3 Stormwater Pollution Prevention Team ...................................................................2-1

2.4 Site Description ....................................................................................................... 2-2

3.0 POTENTIAL POLLUTANT SOURCES ......................................................................... 3-11

3.1 Potential Pollutants Associated with Industrial Activity .......................................... 3-11

3.2 Spills and Leaks .................................................................................................... 3-12

3.3 Unauthorized Non-stormwater Discharges Documentation ................................... 3-14

3.4 Sampling Data Summary ...................................................................................... 3-15

4.0 INDUSTRIAL FACILITY DETAILS BY BUILDING ..........................................................4-1

4.1 Building 320 – NCHB-11 Motor T Shop ...................................................................4-1

4.1.1 Activity-Specific Stormwater Best Management Practices ............................4-1

4.1.2 Potential Pollutant Sources .......................................................................... 4-1

4.2 Building 350 – BIC Tactical Motor T Shop (“Big Blue”) ............................................ 4-2

4.2.1 Activity-Specific Stormwater Best Management Practices ............................ 4-3

4.2.2 Potential Pollutant Sources .......................................................................... 4-3

4.4 Building 351 – BIC Comm/Elec Shop ...................................................................... 4-4

4.4.1 Activity-Specific Stormwater Best Management Practices ............................4-4

4.4.2 Potential Pollutant Sources .......................................................................... 4-4

4.5 Building 354 – BIC “Organic” Motor T Shop ............................................................4-5

4.5.1 Activity-Specific Stormwater Best Management Practices ............................4-5

4.5.2 Potential Pollutant Sources .......................................................................... 4-6

4.6 Building 355 – BIC Battery Shop ............................................................................. 4-7

4.6.1 Activity-Specific Stormwater Best Management Practices ............................4-7

4.6.2 Potential Pollutant Sources .......................................................................... 4-8

4.7 Building 360 – BIC Wash Rack ............................................................................... 4-8 ix

JUNE 2024

4.7.1 Activity-Specific Stormwater Best Management Practices ............................ 4-8

4.7.2 Potential Pollutant Sources .......................................................................... 4-9

4.8 Building 361 – BIC Corrosion Repair Facility ........................................................... 4-9

4.8.1 Activity-Specific Stormwater Best Management Practices ............................4-9

4.8.2 Potential Pollutant Sources ........................................................................4-10

4.9 Building 390 – BIC AGSE Shop ............................................................................4-10

4.9.1 Activity - Specific Stormwater Best Management Practices ........................4-11

4.9.2 Potential Pollutant Sources ........................................................................4-11

4.10 Building 450 – BIC Wood Shop .............................................................................4-12

4.10.1 Activity-Specific Stormwater Best Management Practices ..........................4-12

4.10.2 Potential Pollutant Sources ........................................................................4-13

4.11 Hazardous Waste Storage Buildings .....................................................................4-13

4.11.1 Activity - Specific Stormwater Best Management Practices ........................4-13

4.11.2 Potential Pollutant Sources ........................................................................4-13

4.12 BIC Gantry Crane Maintenance ............................................................................4-14

4.12.1 Activity-Specific Stormwater Best Management Practices ..........................4-15

4.12.2 Potential Pollutant Sources ........................................................................4-15

4.13 Drainage Basin 12 – BIC Military Equipment Parking Area ....................................4-15

4.13.1 Activity - Specific Stormwater Best Management Practices ........................4-16

4.13.2 Potential Pollutant Sources ........................................................................4-16

4.14 Drainage Basin 5 – Berth #4 Crawler Crane Loading/Unloading Area ...................4-16

4.14.1 Activity-Specific Stormwater Best Management Practices ..........................4-17

4.14.2 Potential Pollutant Sources ........................................................................4-17

5.0 SECTOR-SPECIFIC REQUIREMENTS ........................................................................... 5-1

5.1 Sector A (Timber Products Facilities) ...................................................................... 5-1

5.2 Sector Q (Water Transportation Facilities that Have Vehicle Maintenance Shops and/or Equipment Cleaning Operations ) ......................................................................... 5-1

6.0 STORMWATER MEASURES AND CONTROLS ............................................................ 6-1

6.1 Non-numeric Technology-based Effluent Guidelines (Best Management Practices) 6-1

6.1.1 Minimize Exposure ...................................................................................... 6-1

6.1.2 Good Housekeeping .................................................................................... 6-1

6.1.3 Preventative Maintenance............................................................................ 6-3

6.1.4 Spill Prevention and Response .................................................................... 6-3

6.1.5 Sediment and Erosion Control ..................................................................... 6-4

6.1.6 Management of Runoff ................................................................................ 6-4

6.2 Numeric Effluent Limitations Based on Effluent Limitations Guidelines ...................6-5

6.3 Water Quality-based Effluent Limitations and Water Quality Standards ..................6-5

6.4 Employee Training .................................................................................................. 6-5

7.0 INSPECTIONS, ASSESSMENTS, EVALUATION, AND MONITORING .........................7-1

7.1 Routine Facility Inspections..................................................................................... 7-1

7.2 Quarterly Visual Assessments ................................................................................ 7-1 x

JUNE 2024

7.3 Comprehensive Site Compliance Evaluation ........................................................... 7-2

7.4 Analytical Monitoring ............................................................................................... 7-4

7.4.1 Benchmark Monitoring ................................................................................. 7-4

7.4.2 Representative Outfall ................................................................................. 7-1

8.0 REPORTING ................................................................................................................... 8-1

8.1 Discharge Monitoring Report................................................................................... 8-1

8.2 Additional Reporting ................................................................................................ 8-1

9.0 CORRECTIVE ACTIONS ................................................................................................ 9-1

MCSF-BLOUNT ISLAND, JACKSONVILLE, FLORIDA

x

LIST OF TABLES

Table 2-1 Facility Point of Contacts ......................................................................................... 2-1

Table 2-2 Stormwater Pollution Prevention Team ...................................................................2-1

Table 2-3 MSGP - Regulated Industrial Facilities at MCSF-BI ................................................. 2-3

Table 2-4 Drainage Basin Information ..................................................................................... 2-4

Table 3-1 Industrial Sectors at MCSF-BI ............................................................................... 3-11

Table 3-2 Potential Pollutants ................................................................................................ 3-11

Table 3-3 Summary of Sampling Parameters ........................................................................ 3-15

Table 4-1 NCHB-11 Motor T Shop Summary .......................................................................... 4-1

Table 4-2 Potential Pollutant Sources Exposed to Stormwater ................................................ 4-2

Table 4-3 BIC Tactical Motor T Shop Summary ...................................................................... 4-2

Table 4-4 Potential Pollutant Sources Exposed to Stormwater ................................................ 4-3

Table 4-5 BIC Comm/Elec Shop Summary ............................................................................. 4-4

Table 4-6 Potential Pollutant Sources Exposed to Stormwater ................................................ 4-5

Table 4-7 BIC “Organic” Motor T Shop Summary .................................................................... 4-5

Table 4-8 Potential Pollutant Sources Exposed to Stormwater ................................................ 4-6

Table 4-9 BIC Battery Shop Summary .................................................................................... 4-7

Table 4-10 BIC Wash Rack Summary ..................................................................................... 4-8

Table 4-11 Potential Pollutant Sources Exposed to Stormwater .............................................. 4-9

Table 4-12 BIC Corrosion Repair Facility Summary ................................................................ 4-9

Table 4-13 Potential Pollutant Sources Exposed to Stormwater ............................................ 4-10

Table 4-14 BIC AGSE Shop Summary .................................................................................. 4-10

Table 4-15 Potential Pollutant Sources Exposed to Stormwater ............................................ 4-12

Table 4-16 BIC Wood Shop Summary .................................................................................. 4-12

Table 4-17 Potential Pollutant Sources Exposed to Stormwater ............................................ 4-13

Table 4-18 Hazardous Waste Storage Summary .................................................................. 4-13

Table 4-19 Pollutant Sources Exposed to Stormwater ........................................................... 4-13

Table 4-20 BIC Gantry Crane Maintenance Summary ........................................................... 4-14

Table 4-21 Potential Pollutant Sources Exposed to Stormwater ............................................ 4-15

Table 4-22 BIC Military Equipment Parking Area Summary ................................................... 4-15

Table 4-23 Potential Pollutant Sources Exposed to Stormwater ............................................ 4-16

Table 4-24 Berth #4 Crawler Crane Loading/Unloading Area Summary ................................ 4-17

Table 4-25 Potential Pollutant Sources Exposed to Stormwater ............................................ 4-17

Table 7-1 Summary of Inspection ............................................................................................7-3

Table 7-2 Benchmark Monitoring Parameters ......................................................................... 7-5

MCSF-BLOUNT ISLAND, JACKSONVILLE, FLORIDA

xi

Table 7-3 Representative Outfall Drainage Area Summary ..................................................... 7-1

LIST OF APPENDICES

Appendix A: Notice of Intent

Appendix B: FDEP Notice of Intent Acknowledgement Letter

Appendix C: Environmental Resource Permit Stormwater Inspections Report

Appendix D: Facility Location and Site Maps (Figure 1 - Figure 13)

Appendix E: Current Stormwater Pollution Prevention Team Members

Appendix F: Photographic Log

Appendix G: Reportable Spills or Leaks

Appendix H: Routine Facility Inspections

Appendix I: Quarterly Visual Monitoring Form

Appendix J: Comprehensive Site Compliance Evaluation Form

Appendix K: FDEP Multi-Sector Generic Permit - Sector A and Q Excerpts

MCSF-BLOUNT ISLAND, JACKSONVILLE, FLORIDA

xii

ABBREVIATIONS AND ACRONYMS

AGSE Aviation Ground Support Equipment

AST aboveground storage tank

BIC Blount Island Command

BMP best management practice

CCE Comprehensive Site Compliance Evaluation

CO Commanding Officer

COD chemical oxygen demand

CFR Code of Federal Regulations

CWA Clean Water Act

DLADS Defense Logistics Agency Disposition Services

DMR Discharge Monitoring Report

DoD Department of Defense

DOH ELCP Department of Health Environmental Laboratory Certification Program

FDEP Florida Department of Protection

FRP Federal Response Plan

F.S. Florida Statutes

HM Hazardous Materials

HW Hazardous Waste

ICP Integrated Contingency Plan

IDIV Installation Division

INLS Improved Navy Lighterage System

ISO International Standards Organization

JAXPORT Jacksonville Port Authority

MBOS Mayport Base Operating Support

MCMC Marine Corps Maintenance Contractor

MCSF-BI Marine Corps Support Facility Blount Island

MEP military equipment parking mg/L milligrams per liter

MPF Maritime Prepositioning Force

MPS Maritime Prepositioning Ship

MSC Marine Sealift Command

MSGP Multi-Sector Generic Permit

MWR Morale, Welfare, and Recreation

NA not applicable

NAVELSG Navy Expeditionary Logistics Support Group

NCHB-11 Navy Cargo Handling Battalion Eleven

NOI Notice of Intent

NPDES National Pollutant Discharge Elimination System

NRC National Response Center

NSMB Navy Support Management Branch

MCSF-BLOUNT ISLAND, JACKSONVILLE, FLORIDA

xiii

NSWD

non-stormwater discharges

OF outfall

OOD officer of the day

OWS oil/water separator

POC point of contact

POL petroleum, oils, and lubricants

RCP Reinforced Concrete Pipe

SIC Standard Industrial Classification

SJRWMD St. Johns River Water Management District

SPCC Spill Prevention, Control, and Countermeasures

SOP Standard Operating Procedures

SWPPP Stormwater Pollution Prevention Plan

SWPPT Stormwater Pollution Prevention Team

TMDL Total Maximum Daily Load

KGS/Trinity KGS/Trinity Analysis & Development Corp.

USEPA United Stations Environmental Protection Agency

USMC United States Marine Corps

MCSF-BLOUNT ISLAND, JACKSONVILLE, FLORIDA

1-1

1.0 INTRODUCTION

1.1 Multi-Sector Generic Permit

Section 402(p) of the Water Quality Act (CWA) of 1987 requires that operators of facilities, including federal installations, which discharge stormwater associated with industrial activity, obtain permits under the National Pollutant Discharge Elimination System (NPDES) to reduce pollutant loadings and improve the quality of stormwater discharges. In response to these statutes, the U.S. Environmental Protection Agency (USEPA) promulgated final regulations for permit applications associated with stormwater discharges from industrial activities on 16 November, 1990 (USEPA Stormwater regulations; 55 Code of Federal Regulation (CFR) 47989, 56 CFR 12097, 56 CFR 56547, 57 CFR 11393, 40 CFR Parts 122 through 124; and additional related regulations promulgated by state and local regulatory agencies; USEPA, 1990, p.

47990).

The Florida Department of Environmental Protection (FDEP) maintains permitting authority and issues permits for industrial, municipal, and construction discharges through Section 403.0885, Florida Statutes (F.S.). Marine Corps Support Facility Blount Island (MCSF-BI) has coverage under the FDEP Multi-Sector Generic Permit (MSGP), Facility ID FLR05D006-005. The facility is currently permitted under Sector A and Sector Q. The MSGP is administered by FDEP and constitutes authorization to discharge stormwater associated with industrial activity to surface waters under the NPDES. It requires facilities to develop Stormwater Pollution Prevention Plans (SWPPP) and report the results of industry-specific monitoring to the FDEP on an annual basis.

Facilities wishing to obtain coverage under the FDEP MSGP are required to submit a permit application, or Notice of Intent (NOI), to FDEP to verify eligibility for permit coverage. Marine Corps Support Facility Blount Island’s (MCSF-BI) NOI was signed and submitted by mail on 27 January 2021 (Appendix A). Permit coverage became effective 28 January 2021 and will expire on 27 January 2026. A copy of FDEP’s NOI acknowledgement letter (Appendix B) and other correspondences related to the MSGP are kept on-site with this SWPPP.

This SWPPP is prepared under the conditions listed in the FDEP MSGP, which requires preparation and implementation of a facility SWPPP to document the practices and procedures necessary to ensure compliance with the conditions of the MSGP, including the selection, design, installation and maintenance of control measures selected to reduce and/or eliminate pollutants in stormwater discharges and meet effluent limitations.

1.2 Environmental Resource Permits for Stormwater Management Systems

Environmental Resource Permit applications are processed by either FDEP or the St. Johns River Water Management District (SJRWMD) for construction, operation, maintenance, alteration, removal, or abandonment of stormwater management systems. Additionally, a permit is required for alterations resulting in an increase in pollutant loading or peak discharge or a decrease in detention storage. Applicable stormwater management systems include dry detention systems, retention systems, underdrain systems, underground exfiltration systems, wet detention systems, and swale systems.

MCSF-BI has obtained individual Environmental Resource Permits from FDEP and SJRWMD covering six stormwater ponds. The Environmental Resource Permit (ERP) Stormwater Inspections Report (Appendix C), includes copies of the Inspection Certifications for each pond.

ERP Stormwater Inspection was conducted in April 2024.

MCSF-BLOUNT ISLAND, JACKSONVILLE, FLORIDA

1-2

1.3 Stormwater Pollution Prevention Plans Development

PHE-Baker JV2, LLC, under contract to the United States Army Corps of Engineers, Mobile district, has prepared this SWPPP for the Marine Corps Support Facility Blount Island in accordance with the MSGP. Information contained herein was developed from existing construction drawings, site visits, previous SWPPPs, and other MCSF-BI supplied information.

The Installation Division (IDIV) Director, by direction of the Commanding Officer (CO), has NOI signatory authority, in accordance with the MSGP. The IDIV Environmental Engineer also has authority to sign the NOI and SWPPP; and designate positions or individuals as duly authorized representatives for certifying inspection reports, monitoring reports, and other documents required by the MSGP.

This SWPPP for the MCSF-BI, Jacksonville, Florida, facility contains all required elements per the MSGP including but not limited to the following:

• Identification of Stormwater Pollution Prevention Team (SWPPT) members

• Description of the facility property and stormwater flow and discharge

• Identification of facility activities and associated potential pollutant sources

• Notation of areas where potential sources and/or releases can contribute to stormwater pollution

• Facility location and site map(s) showing structures, stormwater conveyances, and outfalls

• Description of any best management practices (BMPs) implemented at the facility

• A summary of existing facility stormwater discharge sampling data

• Discussion of permit requirements, inspection schedules, and corrective actions

• Annual training

• Analytical monitoring

• Non-stormwater discharge certification

MCSF-BLOUNT ISLAND, JACKSONVILLE, FLORIDA

2-1

2.0 FACILITY DESCRIPTION AND CONTACT INFORMATION

2.1 Facility Information

MCSF-BI is located in Jacksonville, Florida, in northeast Duval County. MCSF-BI occupies the east side of Blount Island and is surrounded by the St. Johns River and the Dames Point - Fulton Cutoff of the St. Johns River. The west side of the island is occupied by Blount Island Marine Terminal, which is property of the Jacksonville Port Authority (JAXPORT). MCSF-BI includes a deep-draft slipway for mooring and servicing large vessels. Facility location and site maps are provided in Figure 1 – Figure 13 (Appendix D).

2.2 Contact Information/Responsible Parties

MCSF-BI facility and SWPPP point of contacts (POCs) are listed below in Table 2-1.

Table 2-1 Facility Point of Contacts

POC Name Address Phone E-mail

IDIV Director Michael K.

Erhardt

5880 Channel View Boulevard Jacksonville, Florida 32226

(904) 696-5671 Michael.Erhardt@usmc.mil

IDIV

Environmental Engineer

Taylor Comstock

5880 Channel View Boulevard Jacksonville, Florida 32226

(904)696-5357 taylor.comstock.civ@usmc.m il

2.3 Stormwater Pollution Prevention Team

The SWPPT consists of qualified personnel designated within the facility organization who are responsible for developing, implementing, maintaining, and revising the SWPPP to comply with permit requirements. This includes maintaining stormwater control measures, taking corrective action where necessary to address deficient conditions or to improve the performance of control measures, and modifying the SWPPP to reflect changes made to the control measures. Team members function as emergency coordinators for stormwater related emergencies and coordinate with the personnel identified in the Spill Prevention Control and Countermeasures (SPCC) Plan for all spill response activities. The specific roles and responsibilities of the SWPPT are described below in Table 2-2 and Appendix E.

Table 2-2 Stormwater Pollution Prevention Team

Title Responsibilities

IDIV Director • Signatory authority

IDIV Environmental Engineer/Project Manager

• Serves as Team Lead

• SWPPP review and modification

• Annual Comprehensive Site Compliance Evaluation

• Pond Certification Reports

• Coordinate with contractors

• Ensure SWPPT member training

• Reporting

• Recordkeeping mailto:Michael.Erhardt@usmc.mil

MCSF-BLOUNT ISLAND, JACKSONVILLE, FLORIDA

2-2

Title Responsibilities

Environmental Coordinators assigned to Marine Corps Maintenance Contractor (MCMC), Mayport Base Operating Support (MBOS), and Aviation Ground Support Equipment

(AGSE)

Grounds Contractor

IDIV Zone Manager

• Implement BMPs

• Quarterly Visual Assessments

• Routine Facility Inspections

• Employee training

• Stormwater conveyance system maintenance

(MBOS)

• Improvements and maintenance needed to implement stormwater controls

• Participates in Annual Comprehensive Site Compliance Evaluation

• Reporting

• Recordkeeping

2.4 Site Description

MCSF-BI is property of the United State Marine Corps (USMC) Blount Island Command (BIC) and is home to the following Department of Defense (DoD) tenants and contractors:

• Marine Corps Maintenance Contractor (MCMC)

• Navy Cargo Handling Battalion Eleven (NCHB-11)

• Aviation Ground Support Equipment Contractor (AGSE)

• Mayport Base Operating Support Contractor (MBOS)

• Military Sealift Command (MSC)

Twelve of the MSGP-regulated industrial activities aboard MCSF-BI fall under BIC. The remaining MSGP-regulated industrial activity falls under NCHB-11. BIC provides support to the USMC Maritime Prepositioning Ships (MPSs) Maintenance Cycle operations, an element of the Maritime Prepositioning Force (MPF). The MPSs, supported by BIC, supply the Marine Expeditionary Units for their missions across the globe.

The Installation is generally flat consisting predominantly of paved and unpaved tactical vehicle and equipment staging areas. A central industrial area lies northeast of the deep-draft slipway, between the slipway and the St. Johns River. MCSF-BI also includes natural areas along the riverfront, Lake Tomroy, and Alligator Creek.

A network of pipes, inlets, ditches, and swales conveys stormwater runoff from the 21 drainage areas, each with an associated stormwater outfall. MSGP-regulated industrial activity occurs within the following five drainage basins:

• Drainage Basin 2

• Drainage Basin 5

• Drainage Basin 10

• Drainage Basin 12

• Drainage Basin 13

MCSF-BLOUNT ISLAND, JACKSONVILLE, FLORIDA

2-3

Figure 2 through Figure 13 contain maps depicting MCSF-BI’s major stormwater features including the outline of the drainage basins, directional flow, structural control measures, outfalls, receiving waters, industrial areas, and locations of significant materials exposed to or have the potential to be exposed to precipitation. Table 2-3 presents a list of MSGP-regulated industrial facilities at MCSF- BI. Table 2-4 provides a general description of each basin’s characteristics and lists the MSGP-regulated industrial activity conducted at each basin, including associated buildings. A photographic log of site features and activities is presented in Appendix F.

Table 0-1 MSGP - Regulated Industrial Facilities at MCSF-BI

Figure Number

Primary Building

Drainage Basin

Building Occupant

Industrial Sector Activity Description

320 13 NCHB-11 Q

Marine cargo handling; vehicle and equipment maintenance and repair

4, 8 350 5, 13 MCMC Q

Tactical vehicle and equipment maintenance and repair

4, 5, 6 351 3 MCMC Q

Maintenance and repair of communications and electronic equipment for tactical vehicles and equipment

5, 6 354 13 MCMC Q

Marine cargo handling; vehicle and equipment maintenance, repair, and fueling

7, 13 355

MCMC Q

Reconditioning and trickle charging of lead-acid batteries for tactical vehicles and equipment

4, 8 360

MBOS Q Vehicle and equipment wash rack

9 361 5 MCMC Q

Vehicle and equipment corrosion repair facility

10 390 2, 5 AGSE Q

Aviation ground support equipment maintenance, repair, welding, blasting, and painting

11 450 5 MCMC A

Wood shop for construction of wood pallets and containers, operation of woodchipper

12 Berth #1

10 MCMC Q Gantry crane maintenance/Big Red

7, 13 452, 458 5 MBOS Q Hazardous waste storage

13 459 12 MCMC Q Fuel Filtration Unit (FFU)

13 831 12 MCMC Q Loading/unloading ramp

13 832 12 MCMC Q Loading/unloading ramp

9 Berth #4

5/Back River

MCMC Q Loading/unloading of Improved Navy Lighterage System, crane maintenance

MCSF-BLOUNT ISLAND, JACKSONVILLE, FLORIDA

2-4

Figure Number

Primary Building

Drainage Basin

Building Occupant

Industrial Sector Activity Description

13 Facility 930 Lighterage

Storage Yard

5 NSMB Q Prep and Paint Lighterage

MCSF-BLOUNT ISLAND, JACKSONVILLE, FLORIDA

2-4

Table 2-4 Drainage Basin Information

Basin

ID

Outfall MSGP Regulated

Industrial Activity

Sector

MSGP

Regulated Industrial Building(s)

Basin Area (acres)

Description

1 1 Not Applicable

(NA)

NA NA 5.3

Drainage basin includes a portion of Building 104 (a restaurant) and its associated parking lot, and a small portion of the recreational training track. Stormwater flows in grass swales along the roads and through a reinforced concrete pipe (RCP) under Channel View Boulevard to Outfall 1 (Photo 07) into the St. Johns River. There is no MSGP-regulated industrial activity within this drainage basin. There are no MSGP regulated industrial activities occurring within this drainage basin.

2 2

AGSE

maintenance, repair, welding, blasting, painting, and hazardous material storage

Q 390, 391, 392 394, 396, 608

8.9

Drainage basin includes Building 100, its associated parking areas, the majority portion of the recreational training track, the tennis and basketball courts.

Portions of the AGSE maintenance operations and hazardous material storage, which are the MSGP-regulated industrial activities. Outfall 2 (Photo 08) discharges to the St. Johns River via a 36-inch diameter RCP.

3 3 NA NA NA 1.1

Drainage basin includes only a portion of Channel View Boulevard and the grassed swales along the northwest side of road. The swales drop into a catch basin. A 30-inch diameter RCP carries the flow to Outfall 3 (Photo 09), where it discharges to the St.

Johns River. There is no MSGP-regulated industrial activity within this drainage basin. There are no MSGP regulated industrial activities occurring within this drainage basin.

4 4 NA NA NA 2.3

Drainage basin consists of a pervious area north of the test track that drains to the MCSF-BI slipway (Back River) via a grassed swale (Outfall 4) (Photo 10).

MCSF-BLOUNT ISLAND, JACKSONVILLE, FLORIDA

2-5

Outfall MSGP Regulated

Industrial Activity

Sector

MSGP

Regulated Industrial Building(s)

Basin Area (acres)

Description

There are no MSGP regulated industrial activities occurring within this drainage basin.

Tactical vehicle and equipment maintenance and repair

Q 350, 472

Drainage basin encompasses the eastern peninsula (created by the slipway) of MCSF-BI and concentrates at Pond B (Photo 02), whose outlet (Outfall 5) discharges to a small inlet that flows into the St. Johns River. Pond B receives runoff from the eastern half of the large tactical vehicle maintenance facility (Building 350, “Big Blue”), Building 361, the centralized vehicle and equipment corrosion repair facility, the AGSE maintenance facility, and two other MSGP-regulated industrial activities. Pond B also receives runoff from the hazardous material (HM) and hazardous waste (HW) storage buildings and the Defense Logistics Agency Disposition Services (DLADS) lot (also referred to as DRMO lot).

Drainage basin includes a portion of Berth No. 4, which includes the NSMB crawler crane and an associated paved staging area. The crawler crane will be utilized for loading and unloading INLS from the Back River.

Loading and unloading activities and maintenance to the crawler crane is classified as MSGP- regulated industrial activity. The crawler crane area will discharge to Outfall 5 (Photo 11) or run-off into the Back River.

Reconditioning and trickle charging of lead-acid batteries for tactical vehicles and equipment

Q 355, 453

Vehicle and equipment corrosion repair facility

Q 361

AGSE

maintenance, repair, welding, blasting, and painting

Q

390, 391 392, 394 396, 608

116.5

5 5

Wood shop for construction of wood pallets and containers

A 450

Petroleum, oils, and lubricants (POL) Storage

Building

Q 451

MCSF-BLOUNT ISLAND, JACKSONVILLE, FLORIDA

2-6

Outfall

MSGP

Regulated Industrial Activity

Sector

MSGP

Regulated Industrial Building(s

Basin Area (acres)

Description

5 5

Hazardous Waste Storage Building

Q 452, 458

See Above Description

Loading/Unloading of INLS, crawler crane maintenance

Q Berth #4

Painting water craft (lighterage)

Q Facilty 930 Lighterage

Storage Yard

6 6 NA NA NA 11.6

Drainage basin includes a natural pond (Photo 12) and a portion of a paved storage lot used for storage of shipping containers. The natural pond discharges to Lake Tomroy via RCP culverts under an access road.

There are no MSGP regulated industrial activities occurring within this drainage basin.

8 8 NA NA NA 2.6

Drainage basin includes a portion of the railroad tracks and associated swales. The basin discharges to Alligator Creek via a 15-inch RCP (Photo 14). There are no MSGP regulated industrial activities occurring within this drainage basin.

9 9 NA NA NA 0.1

Small drainage basin is predominantly pervious but includes a small portion of an adjacent road surface.

The basin discharges to Alligator Creek via an 18-inch RCP (Photo 15). There are no MSGP regulated industrial activities occurring within this drainage basin.

MCSF-BLOUNT ISLAND, JACKSONVILLE, FLORIDA

2-7

Outfall

MSGP Regulated Industrial Activity

Sector

MSGP

Regulated Industrial Building(s)

Basin Area (acres)

Description

10 10 Gantry crane maintenance

Q Berth #1 5.2

Drainage basin includes Berth No. 1, which includes the Gantry crane and an associated paved staging area. Maintenance to the gantry crane is classified as MSGP- regulated industrial activity. Outfall 10 (Photo

16) discharges to the slipway via a 24-inch diameter pipe.

11 11 NA NA NA 45.2

Drainage basin concentrates at Pond D (Photo 04) whose outlet (Outfall 11) (Photo 17) discharges to the Dames Point - Fulton Cutoff of the St. Johns River via a 60-inch diameter RCP. The basin consists of paved and gravel vehicle and equipment staging lots.

Stormwater from these lots flows into a central, open channel that flows to Pond D. There is no MSGP-regulated industrial activity within this drainage basin.

There are no MSGP regulated industrial activities occurring within this drainage basin.

12 12

Vehicles and Equipment

Loading/Unloading Operations;

Mobile Fueling Operations

Q 459, 831, 832 128.0

Drainage basin concentrates at Pond C (Photo 03), whose outlet (Outfall 12 [Photo 18], three 30-inch diameter pipes) discharges to Alligator Creek along the western boundary of MCSF-BI. The basin consists predominantly of paved vehicle and equipment staging lots. Stormwater is conveyed to Pond C by a combination of piped and open channel flow. MSGP-regulated activities include vehicle equipment loading and unloading and mobile fuel filtration operations.

Marine cargo handling; vehicle and equipment

Q 320, 321T

Drainage basin encompasses the northern portion of MCSF-BI and concentrates at Pond A (Photo 01), whose outlet (Outfall 13 [Photo 19], three 60-inch

MCSF-BLOUNT ISLAND, JACKSONVILLE, FLORIDA

2-8

Regulated Industrial Building(s)

Basin

13 13 maintenance and repair

128.7 diameter pipes) discharges to a small inlet that flows into the St. Johns River. Pond A receives runoff from various MSGP-regulated industrial activities including the western half of the large tactical vehicle maintenance facility (Building 350, “Big Blue”), the communications and electronics shop (Building 351), marine cargo handling and vehicle and equipment maintenance facilities at Buildings 320 and 350/354, and the centralized vehicle and equipment wash rack (Building 360). This basin also includes the main entrance to MCSF-BI, the undeveloped area north of the Lake Tomroy’s northern shoreline, and the grassy area north of the main entrance along Channel View Boulevard.

Tactical vehicle and equipment maintenance and repair

Q 350

Maintenance and repair of communications and electronics for tactical vehicles and equipment

Q 351

Marine cargo handling; vehicle and equipment maintenance, repair, and fueling

Q 351, 354

359C, 366T 449, 468

Vehicle and equipment wash rack Q 360

14 14 NA NA NA 3.9

Drainage basin consists of a grassy area and a natural area that drain to Alligator Creek via a natural channel downstream of a culvert under an access road (Photo 20). There are no MSGP regulated industrial activities occurring within this drainage basin.

Drainage basin south of Pond C (Photo 03) includes a grassy lawn area. Outfall 15 (Photo 21) discharges outside of the installation security fence to Alligator Creek via an 18-inch RCP. There are no MSGP

MCSF-BLOUNT ISLAND, JACKSONVILLE, FLORIDA

2-9

Regulated Industrial Building(s)

Basin

NA

1.7 regulated industrial activities occurring within this drainage basin.

8.3

Drainage basin includes the Moral, Welfare, and Recreation (MWR) and Marine Sealift Command (MSC) storage facilities. Storage facilities and associated storage lots drain to a ditch that discharges at Outfall 16 (Photo 22) to Alligator Creek. There are no MSGP regulated industrial activities occurring within this drainage basin.

0.7

Drainage area is half of a paved vehicle and equipment storage lot that drains to a catch basin. The catch basin connects by pipe to Outfall 17 (Photo 23), which discharges to the St. Johns River. There are no MSGP regulated industrial activities occurring within

0.7

Drainage area is half of a paved vehicle and equipment storage lot that drains to a catch basin. The catch basin connects by pipe to Outfall 18 (Photo 24), which discharges to the St. Johns River. There are no

7.1

Drainage area is half of paved retrograde lot in the southern portion of installation. Runoff sheet flows into Pond E (Photo 05) via grassed area. The pond outfalls directly to the St. Johns River (Photo 25). There are no

MCSF-BLOUNT ISLAND, JACKSONVILLE, FLORIDA

2-10

Regulated Industrial Building(s)

Basin

20 20 NA NA NA 6.0

Drainage area is half of paved retrograde lot in the southern portion of installation. Runoff sheet flows into Pond F (Photo 06) via grassed area. The pond outfalls into a vegetated wetlands area that ultimately drains to the St. Johns River (Photo 26). There are no MSGP regulated industrial activities occurring within this drainage basin.

21 21 NA NA NA 0.7

Drainage area receives stormwater from the roof drain of Building 420 (Photo 27). There are no MSGP regulated industrial activities occurring within this drainage basin.

Note: Photos are presented in Appendix F - Photographic Log

3-11

3.0 POTENTIAL POLLUTANT SOURCES

3.1 Potential Pollutants Associated with Industrial Activity

This section of the SWPPP provides details regarding each MSGP-regulated industrial activity at MCSF-BI including descriptions of operations, surrounding drainage characteristics, discharge monitoring requirements, and measures and controls to prevent stormwater pollution.

MCSF-BI has five drainage basins that include MSGP-regulated industrial activity. Drainage Basins 2, 10, 12, and 13 include Industrial Sector Q (Water Transportation Facilities that have Vehicle Maintenance Shops and/or Equipment Cleaning Operations) activities. Drainage Basin 5 includes Sector A (Timber Products Facilities) and Sector Q activities. Table 3-1 presents applicable industrial sectors and their descriptions.

Table 3-1 Industrial Sectors at MCSF-BI

Industrial Sector SIC Major Group

Description

Sector A – Timber Products Facilities

Major Group 24

– Lumber and Wood Products, Except Furniture

Establishments engaged in cutting timber and pulpwood; merchant saw mills, lath mills, shingle mills, cooperage stock mills, plaining mills, and plywood and veneer mills engaged in producing lumber and wood basic materials;

and establishments engaged in manufacturing finished articles made entirely or mainly of wood or related materials

Sector Q – Water Transportation Facilities that Have Vehicle Maintenance Shops

Major Group 44 – Water Transportation

Establishments engaged in freight and passenger transportation on the open seas or inland waters, and establishments furnishing such incidental services as lighterage, towing, and canal operation

SIC = Standard Industrial Classification

Table 3-2 lists potential activities or materials, potential pollutant sources, and potential pollutants associated with Sector A and Sector Q industrial activities. The site maps (Figures 2-

13) note the location of vehicle and equipment maintenance and repair areas, processing areas (painting, blasting, welding, and metal fabrication), liquid storage areas, and material storage areas.

Table 3-2 Potential Pollutants

Sector Q: Water Transportation Facilities that Have Vehicle Maintenance Shops and/or Equipment Cleaning Operations; Marine Cargo Handling

Activity or Material Pollutant Source Potential Pollutant

Pressure washing Wash water Paints solids, heavy metals, suspended solids

Surface preparation, paint removal, sanding

Sanding, mechanical grinding, abrasive blasting, paint stripping

Spent abrasives, paint solids, heavy metals, solvents, dust

3-12

Sector Q: Water Transportation Facilities that Have Vehicle Maintenance Shops and/or Equipment Cleaning Operations; Marine Cargo Handling

Activity or…

This is the start of the file's text. The full file is on GovTribe.