Attach 6 System Software Configuration COTS and GFP.doc
DOC document 84 KB Posted
- Solicitation number
- N68335-11-R-0020
About this file
Attach 6 System Software Configuration COTS and GFP
View the file
Other files
| File | Type | Posted |
|---|---|---|
| EXHIBITS A L TPTI CDRLs 3-9-11.doc | DOC document | |
| RELEASED 11-R-0020 AMD 0006.doc | DOC document | |
| RELEASED 11-R-0020 AMD 0005.doc | DOC document | |
| Attach 10 PBP milestones 2-28-11.xls | XLS spreadsheet | |
| RELEASED 11-R-0020 AMD 0003.doc | DOC document | |
| RELEASED 11-R-0020 AMD 0002.doc | DOC document | |
| Attach 10 PBP milestones 2-17-11.xls | XLS spreadsheet | |
| RELEASED 11-R-0020 AMD 0001.doc | DOC document | |
| EXHIBITS A L TPTI CDRLs 2-10-11.doc | DOC document | |
| EXHIBITS A L TPTI CDRLs 7-30-10.doc | DOC document | |
| Attach 9 TPTI ILSSOW 10-14-10.doc | DOC document | |
| RELEASED N68335-11-R-0020 RFP TPTI.doc | DOC document | |
| Attach 10 PBP milestones 11-24-10.xls | XLS spreadsheet | |
| Attach 1 TPTI Production SOW 7-30-10.doc | DOC document |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TPTI – COTS and Developmental Software Specification
TPTI System Software
TPTI System COTS and Developed Software
This table describes:
(1) COTS software to be loaded on the TPTI system and
(2) Navy/Contractor developed Engine Test Software (Data Acquisition, Test Program Set, and support software)
| Software Item |
| Vendor and/or P/N |
| T PTI 1 |
| T P T I 2 |
| Description |
| Notes |
| Installation |
| Windows XP Pro with SP3 |
| Microsoft |
| X |
| X |
| Microsoft Windows Operating System for SETI-1 and SETI-2 computers |
Pre-installed on system
| Office 2007 |
| Microsoft |
| X |
| X |
| Microsoft Windows Office v12 |
| Used for generating reports from LabView. |
| Pre-installed on system |
| Norton Ghost 2003 |
| Symantec |
| X |
| X |
| Disk imaging and backup software |
| Used to restore system disk. |
| Installed from TPTI System build install CDs |
| VNC Viewer v3.3.3r9 |
| VNC |
| X |
| X |
| Remote computer interface and control |
| Used for interface to Throttle computer for setup |
| Installed from TPTI System build install CDs |
| WinZip v8.1 |
| Winzip |
| X |
| X |
| Compression Utility |
| Acrobat Reader 8.2 |
| Adobe |
| X |
| X |
| PDF Reader (freeware) |
| Standard reader for technical manuals, MMIs etc. |
| Nero CD Burner v6 |
| Nero |
| X |
| X |
| CD Burner Software |
| Used to transfer data to CD |
| NI-VXI 3.5.2.2 |
| National Instruments |
| X |
VXI Drivers – Interface software for VXI controllers.
Installed from TPTI System build install CDs
| NI-VISA 4.4.1 |
| National Instruments |
| X |
VISA interface
Installed from TPTI System build install CDs
| NI-DAQ 7.4.4f7 |
| National Instruments |
| X |
| X |
| DAQ Instrument interface drivers |
| Interface with 6023 PCI backup card |
| Installed from TPTI System build install CDs |
| NI LabView Run Time Engine v8.6.1 |
| National Instruments |
| X |
| X |
| Shared libraries required to run LabView executables. |
| May upgrade prior to production system FAT |
| Installed from TPTI System build install CDs |
| Driver – Touch-screen monitor |
| ELO Touchsystems |
| X |
| X |
| Touch-screen driver for monitor |
| Driver supplied by instrument OEM |
Driver – Printer(s)
| X |
| X |
| Printer Driver |
| Printer drivers to support printer installed on system |
| MX Foundation v3.6.1 |
| MaxTech |
| X |
| MaxTech Card Driver |
| libvisab.dll is installed as version 1.1. It must be replaced with version 1.5 |
Driver
V2.04 Racal Instruments
RI-2461-C
X
| Driver – Universal counter |
| Driver supplied by instrument OEM |
Driver
1260a Racal Instruments
1260-145B 407643-002 X
| Driver –Switch Matrix |
| Driver supplied by instrument OEM |
Driver
1261B Racal Instruments
1260-45A 407052-101 X
| Driver –Switch Matrix |
| Driver supplied by instrument OEM |
| Driver – PCI200H |
| VSCOM |
| X |
VSCOM PCI Driver
| Driver – PCI400I |
| VSCOM |
| X |
VSCOM PCI Driver
| Driver |
| National Instruments |
777742-01
| X |
| Driver – PCI 6023E Multifunction I/O Card |
| Driver supplied by instrument OEM National Instruments PCI Data Acquisition Card on TPS computer for backup |
Driver
HPE1413
VXI Technologies
73-0022-000 X
| Driver – A/D converter |
| Driver supplied by instrument OEM |
VXI Technologies scanning A/D converter
| DAQ Software CD |
| TPTI-DAQ-xxx |
| X |
| LabView based Data Acquisition system executable. |
| Built from Navy software baseline |
| Installed from TPTI DAQ software release CD |
| T56 -425/-427 Software CD |
| TPTI-T56-1xx |
| X |
| LabView based Test Program Set Software executable for T56 -425/-427 |
| Built from Navy software baseline |
| Installed from TPTI TPS software release CD |
T56
-427A Software CD TPTI-T56-4xx
| X |
| LabView based Test Program Set Software executable for T56 -427A |
| Built from Navy software baseline |
| Installed from TPTI TPS software release CD |
DAQ Probe
| X |
| LabView based software interface to TPTI-1 DAQ system |
| Used for ATP and troubleshooting. |
| GFM from CD |
Navy PC Configuration Management Workstation
| Hardware Item |
| P/N or S/N |
| Description |
| Notes |
Computer
| P IV 2.0 GHz |
| Used for software configuration management of TPTI software baseline. |
Monitor
17” Monitor
Network card
Network Interface Card
CD Burner
| CD burner |
| Use included Adaptec CD software |
Tape Backup
| DAT tape backup drive |
| Use for daily and offsite backups of CM system. |
| Microsoft Visual SourceSafe |
| V6.0 |
| Source Control software |
| Used for software configuration management of TPTI software. |
| Install Shield Express |
| V5.0 or later |
| Installation software creation |
| LabView – Professional Development Software |
| V6.1 |
| May be upgraded prior to production |
| Need to purchase newer version for license. Newer version should not be installed. |
Lakehurst Lab TPTI Software Development Station TPTI Development System COTS and Developmental Software Requirements
Required items for software development and distribution
| Software Item |
| P/N or S/N |
| SETI-1 |
| SETI-2 |
| Description |
| Notes |
| LabView – Professional Development Software V8.6.1 |
| V8.6.1 |
| X |
| X |
| May be upgraded prior to production |
| Need to purchase newer version for license. Newer version should not be installed. |
All other software from the TPTI Production Configuration
| X |
| X |
All software and drivers from pages 1-4 are required on the development system.
Attachment 21 A21-1