24R1312 Note 7.pdf
PDF 176 KB Posted
- Solicitation number
- N6274224R1312
About this file
This document provides pre-proposal questions and answers for Request for Proposal N6274224R1312. The Naval Facilities Engineering Command issued the RFP to solicit proposals for a construction project to build a new recreation center at Marine Corps Base Guam in Finegayan. One question asked whether gaskets could be used for joints between precast manhole sections, given they are cast without grooves. The answer confirmed that preformed butyl rubber sealants meeting ASTM C990 are an acceptable alternative for sealing the joints. Specification Section 33 30 00 will be revised in an upcoming amendment to reflect this.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 24R1312_AMD08.pdf | ||
| 24R1312_AMD07.pdf | ||
| P-406 DRAWINGS AMD06.pdf | ||
| 24R1312_AMD06.pdf | ||
| 24R1312 Note 6.docx | DOCX document | |
| P-406 DRAWINGS AMD05.pdf | ||
| 241312_AMD05.pdf | ||
| 24R1312_AMD04.pdf | ||
| 24R1312 Note 5.pdf | ||
| 24R1312 Note 4.pdf | ||
| 24R1312 Note 3.pdf | ||
| 24R1312_AMD0003.pdf | ||
| 24R1312 Note 2.pdf | ||
| 24R1312_AMD02.pdf | ||
| P-406 Site Visit Sign In Sheet.pdf | ||
| 24R1312_AMD01.pdf | ||
| 24R1312 Note 1.pdf | ||
| 3_P406 Drawings_Part2.pdf | ||
| 4_P406 Drawings_Part3.pdf | ||
| 24R1312-JA.ZIP | ZIP file | |
| 2_P406 Drawings_Part1.pdf | ||
| 1_P406 Specs.pdf | ||
| 0_24R1312-RFP.pdf |
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Notice No. 7
12 December 2023
PRE-PROPOSAL QUESTIONS & ANSWERS
RFP N62742-24-R-1312
FY24 MCON P-406 RECREATION CENTER,
US NAVSUPPACT MCB GUAM, FINEGAYAN, GUAM
NOTE: The following questions and answers are provided for INFORMATION ONLY. The RFP remains unchanged unless it is amended in writing on a Standard Form 30.
31. (Section 33 30 00, para. 2.2.6. Provide gaskets for joints between manhole sections conforming to ASTM C443) Use of Gaskets for manholes is impractical, as manhole sections are pre-casted without grooves where gaskets can rest during installation. Propose to use butyl sealand per ASTM C990.
ANSWER: Use of Preformed Butyl Rubber Sealants conforming to ASTM C990 is an acceptable material for sealing joints for precast concrete. Specification Section 33 30 00 will be revised in the forthcoming amendment.
End of Notice