24R1312_AMD0003.pdf
PDF 8 MB Posted
- Solicitation number
- N6274224R1312
About this file
This document package includes construction drawings and specifications for a federal construction contract opportunity. The solicitation is for a FY24 Military Construction Project to build a new Recreation Center at the U.S. Naval Support Activity facility in Finegayan, Guam. The contract drawings show floor plans, elevations, and details for the building, including doors, windows, lighting and signage. Specification sections outline requirements for aluminum doors and frames, lighting, and site work. The opportunity is being conducted by the Naval Facilities Engineering Command Pacific for the Department of the Navy. The solicitation number is N6274224R1312. Responses are due in accordance with the revised schedule and drawings provided in Amendment 0003.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 24R1312_AMD08.pdf | ||
| 24R1312_AMD07.pdf | ||
| P-406 DRAWINGS AMD06.pdf | ||
| 24R1312_AMD06.pdf | ||
| 24R1312 Note 7.pdf | ||
| 24R1312 Note 6.docx | DOCX document | |
| P-406 DRAWINGS AMD05.pdf | ||
| 241312_AMD05.pdf | ||
| 24R1312_AMD04.pdf | ||
| 24R1312 Note 5.pdf | ||
| 24R1312 Note 4.pdf | ||
| 24R1312 Note 3.pdf | ||
| 24R1312 Note 2.pdf | ||
| 24R1312_AMD02.pdf | ||
| P-406 Site Visit Sign In Sheet.pdf | ||
| 24R1312_AMD01.pdf | ||
| 24R1312 Note 1.pdf | ||
| 3_P406 Drawings_Part2.pdf | ||
| 4_P406 Drawings_Part3.pdf | ||
| 24R1312-JA.ZIP | ZIP file | |
| 2_P406 Drawings_Part1.pdf | ||
| 1_P406 Specs.pdf | ||
| 0_24R1312-RFP.pdf |
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RFP No. N6274224R1312
Amendment No. 0003
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
The following items are applicable to this modification:
SPECIFICATIONS
SECTION 08 11 16 – ALUMINUM DOORS AND FRAMES
Remove Replace with
Page 5 Page 5
Amendment No. 0003
DRAWINGS
The following drawings supersede previously issued drawings bearing the same number and title:
DRAWING
NUMBER
NAVFAC
DRAWING
NUMBER
REVISION
NUMBER
DRAWING TITLE
S-551 17302033 1 MISCELLANEOUS DETAILS
A-601 17302080 1 DOOR SCHEDULE & NOTES
EP118 17302210 1 FLOOR PLANS & ENLARGED DETAILS - CLERESTORY
ES121 17302234 1 SITE LIGHTING PLAN
(End of Summary of Changes)
FY24 MCON P-406 RECREATION CENTER 1737348
US NAVSUPPORT MCB GUAM, FINEGAYAN, GUAM
of anchorage, glazing details, provisions for an location of hardware, mullion details, method and materials for flashing and weatherstripping, miscellaneous trim, installation details, and other related items necessary for a complete representation of all components.
1.5.2 Finish Samples
Submit two color charts and two finish sample chips from manufacturer's standard color and finish options for each type of finish indicated.
1.5.3 Operation and Maintenance Data
Submit detailed instructions for installation, adjustments, cleaning, and maintenance of each type of assembly indicated.
1.6 QUALITY ASSURANCE
PART 2 PRODUCTS
2.1 DOORS AND FRAMES
Provide heavy-duty swing-type aluminum doors and frames of size, design, and location indicated. Provide doors complete with frames, framing members, subframes, transoms, adjoining side lites , trim, and accessories. Coordinate side lites, with Section 08 41 13
ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS.
2.2 MATERIALS
2.2.1 Anchors
Type 316, stainless steel .
2.2.2 Weatherstripping
Continuous ultraviolet (UV) resistant, vinyl type recommended by door manufacturer.
2.2.3 Aluminum Alloy for Doors and Frames
ASTM B221M, ASTM B221, Alloy 6063-T5 for extrusions. ASTM B209M, ASTM B209, alloy and temper best suited for aluminum sheets and strips. Provide aluminum materials that include a minimum of 30 percent recycled content.
Provide data indicating percentage of recycled content of aluminum material.
2.2.4 Fasteners
Type 316, stainless steel.
2.2.5 Structural Steel
ASTM A36/A36M.
2.2.6 Aluminum Paint
Aluminum door manufacturer's standard aluminum paint.
SECTION 08 11 16 Page 5 Amendment 0003
11/07/2023
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
OF
EPROJECT NO.:
DM
BRANCH MANAGER
CHIEF ENG
FIRE PROTECTION
A.
B.
C.
D.
E.
F.
G.
H.
MANUFACTURER'S NAME & NUMBERS SHOWN IN DETAILS ARE USED TO INDICATE
DESIRED DESIGN INTENT & REQUIREMENTS ONLY. PRODUCTS OF OTHER
MANUFACTURERS WHICH MEET THE SPECIFIED REQUIREMENTS OF THIS
CONTRACT MAY BE USED IF SIMILAR IN DESIGN & FUNCTION.
HOLLOW METAL DOOR FRAMES SHALL BE PACKED 100% FULL WITH MINERAL
WOOL. REFER TO DOOR DETAILS ON SHEETS A-501 AND A-502.
STC RATED DOOR ASSEMBLIES SHALL HAVE FRAME, PANEL AND SEALS PROVIDED BY
THE DOOR MANUFACTURER, AND TESTED AND ASSEMBLED BY A SINGLE
MANUFACTURER. SELF ADHESIVE SEALS ARE ONLY ACCEPTABLE FOR STC RATINGS
LESS THAN 45, AND ONLY IF 3-FIN OR 4-FIN TYPES ARE USED. COMPRESSION BULB
SEALS ARE NOT ACCEPTABLE UNLESS USED IN COMBINATION WITH OTHER SEAL
TYPES.
DOORS RATED STC 44 OR BELOW MAY BE SUPPLIED WITH A FRAME BY ANY
MANUFACTURER. DOORS RATED STC 45 OR ABOVE SHALL BE PROVIDED WITH
A FRAME PROVIDED BY THE DOOR MANUFACTURER, CONSISTED WITH THE
DOOR'S STC RATING.
COORDINATE ALL DOOR SECURITY HARDWARE SUCH THAT IT DOES NOT
INTERFERE WITH DOOR SEALS AT ANY LOCATION.
REFERENCE DOOR TYPES ON SHEET A-602, & DOOR DETAILS ON SHEETS
A-501.
REFER TO TECHNICAL SPECIFICATIONS (08 71 00) FOR DOOR
HARDWARE SCHEDULE
ALL EXTERIOR DOORS SHALL BE CAPABLE OF WITHSTANDING POSITIVE AND
NEGATIVE PRESSURE FROM 195 MPH WIND SPEED @ EXPOSURE C.
GENERAL NOTES
DOOR SCHEDULE REMARKS
CODE DESCRIPTION
DIMENSIONS GIVEN ARE FOR ENTIRE DOOR OPENING
REFERENCE RECESSED WALK OFF MAT ON DETAIL C3 SHEET A-703
SMOKE PARTITION DOOR
PROVIDE FIRE/SAFETY RATED GLASS
6 PROVIDE ELECTRIFIED LOCKSET, HINGE, OUTLET BOXES, AND CONDUITS AS
7 PROVIDE MANUAL LOCKSET
PROVIDE EXPLOSION-PROOF MOTOR
PROVIDE FULL PERIMETER ACOUSTICAL SEALS AND DOOR BOTTOM.
REFER TO HARDWARE SETS IN SPECIFICATION 08 71 00.
SPECIFIED IN SPECIFICATION 08 71 00 AND TELECOM DWGS.
PROVIDE WINDBORNE DEBRIS IMPACT-RESISTANT LAMINATED GLASS
PROVIDE EXIT DEVICE
11 PROVIDE DECORATIVE TREATMENT ON DOOR AND SIDELIGHT GLAZING.
DOOR SCHEDULE ABBREVIATIONS
AA ANODIZED ALUMNUM
AL ALUMINUM
CLR CLEAR
DBL DOUBLE
DR DOOR
FIN FINISH
FP FACTORY PAINTED
FRP FIBERGLASS REINFORCED POLYESTER
GALV GALVANIZED METAL
GS GALVANIZED STEEL
HDW HARDWARE
HM HOLLOW METAL
MATL MATERIAL
MIN MINIMUM
NO NUMBER
PU POLYURETHANE
PT PAINTED
SC SOLID CORE
SST STAINLESS STEEL
THK THICK
UL UNDERWRITERS LABORATORIES
WD WOOD
T TEMPERED
L LAMINATED
M METAL
IGU INSULATED-LAMINATED GLASS UNIT
FF FACTORY FINISHED
ESS ELECTRONICS SECURITY SYSTEM
STC SOUND TRANSMISSION CLASS
AS ACOUSTICAL SEAL
KEYING GROUPS
A
B
D E
C
CODE DESCRIPTION
GENERAL BUILDING ACCESS FROM EXTERIOR (WORKERS USE IT TO GET INTO
BUILDING PRIOR OR AFTER WORKING HOURS.)
GENERAL INTERIOR BUILDING ACCESS (WORKERS USE IT TO GET INTO MAIN
BUILDING SPACE DURING WORKING HOURS.)
PRIVATE OFFICE
CARD KEY ACCESS - UTILITY ROOMS
X EXTERIOR GATES. ASSUMING PADLOCKS WHICH MAY HAVE THEIR OWN KEYS.
CARD KEY ACCESS - SENSITIVE AREAS (GTR)
17302080
A-601
D O
O R
S C
H E
D U
LE
N O
TE
S
11/07/2023
AutoCAD SHX Text
SATISFACTORY TO
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
EE
AutoCAD SHX Text
JV
AutoCAD SHX Text
NK
AutoCAD SHX Text
03 NOV 2023
AutoCAD SHX Text
AMENDMENT 0003 - REVISE DOOR SCHEDULE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
OF
EPROJECT NO.:
DM
BRANCH MANAGER
CHIEF ENG
FIRE PROTECTION
NA
VF
AC
P
AC
IF
IC
NA
VF
AC
P
AC
IF
IC
MA
KA
LA
PA
, H
AW
AI
I
US
N
AV
SU
PP
AC
T M
CB
G
UA
M
FI
NE
G
AY
AN
, G
UA
M
FY
M
CO
N P-
RE
CR
EA
TI
O N
CE
NT
ER
08/22/2023
MPU
BMC
JCC
1737348
APPROVED BY RANDALL TORIGOE,
MILCON PLANNER, DPP-H
VIA EMAIL
POWER - EXTERIOR ELEVATION - SOUTH - CLERSTORY
SCALE: 3/16"=1'-0" 1EP111
A. PROVIDE 24"X24" ACCESS PANEL TO ALL STORM SHUTTER AND
ROLLER SHADE DISCONNECTS. SEE D2/A521 FOR DETAILS.
B. MOTOR AND DISCONNECTS SHOWN ARE NOTATIONAL, LOCATE
NEARBY DISCONNECTS SO THAT ACCESS PANELS MAY BE SHARED.
C. ELECTRICAL EQUIPMENT SHOWN ON EXTERIOR ELEVATIONS FOR
ILLUSTRATION PURPOSES ONLY. ALL EQUIPMENT TO BE INSTALLED
ON INTERIOR OF BUILDING.
D. LIGHTNING PROTECTION AIR TERMINALS SHOWN ARE FOR
ILLUSTRATION PURPOSES ONLY.
1. NA
W 2M1-2
ABV
2M1-14
ABV
2M1-12
ABV
2M1-10
ABV
2M1-8
ABV
2M1-6
ABV
2M1-4
ABV
2M1-2
ABV
2M1-4
ABV
2M1-6
ABV
2M1-8
ABV
2M1-10
ABV
2M1-12
ABV
2M1-14
TO CUSTOMER
SERVICE STORM
SHUTTER CONTROL
TO CUSTOMER
SERVICE ROLLER
SHADE CONTROL
TO CUSTOMER
SERVICE ROLLER
SHADE CONTROL
FL
O
O R
P
LA
N S
E
N
LA
R G
E D
D E
TA
IL
S
C
LE
R E
S
TO
R Y
EP118
JKS
AC
C
ES
S
PA
N
EL
S
IZ
E
C
LA
R
IF
IC
AT
IO
N
N
O V
11/07/2023
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text
SATISFACTORY TO
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
PLAN NORTH
AutoCAD SHX Text
TRUE NORTH
AutoCAD SHX Text 8'
AutoCAD SHX Text 12'
AutoCAD SHX Text 4'
AutoCAD SHX Text
SCALE: 3/16" = 1'-0"
AutoCAD SHX Text 4'
AutoCAD SHX Text 0'
AutoCAD SHX Text 2'
AutoCAD SHX Text X
AutoCAD SHX Text 17302210
AutoCAD SHX Text
AutoCAD SHX Text
BZL
AutoCAD SHX Text
BZL
AutoCAD SHX Text
SAT
AutoCAD SHX Text
11/7/2023 8:40 AM
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
OF
EPROJECT NO.:
DM
BRANCH MANAGER
CHIEF ENG
FIRE PROTECTION
NA
VF
AC
P
AC
IF
IC
NA
VF
AC
P
AC
IF
IC
MA
KA
LA
PA
, H
AW
AI
I
US
N
AV
SU
PP
AC
T M
CB
G
UA
M
FI
NE
G
AY
AN
, G
UA
M
FY
M
CO
N P-
RE
CR
EA
TI
O N
CE
NT
ER
08/22/2023
MPU
BMC
JCC
1737348
APPROVED BY RANDALL TORIGOE,
MILCON PLANNER, DPP-H
VIA EMAIL
INVERTER FOR EXTERIOR LIGHTS
SCALE: NO SCALE
TRENCH DETAIL (TYPICAL)
SCALE: NO SCALE 3 2
LIGHT POLE DETAIL
SCALE: NO SCALE 1
FT
8F T
3F T
" M
IN
LIGHTING HANDHOLE DETAIL
SCALE: NTS 4
NOTES:
1. HOUSING SHALL BE POLYMER
CONCRETE REINFORCED WITH A HEAVY
WEAVE FIBERGLASS REINFORCING
WITH COMPRESSIVE STRENGTH OF
LESS THAN 10,000 PSI.
2. COVER AND BOX SHALL WITHSTAND A
SERVICE LOAD OF LESS THAN 15,000
LBS OVER A 10" X 10" AREA.
3. PROVIDE STAINLESS STEEL BOLTS AND
INSERTS.
4. PROVIDE WITH (2) 2 1/2" MOUSEHOLES.
ES121
MONUMENT SIGN DETAIL
SCALE: NO SCALE 5
2FT
5.5
FT
R
EV
IS
ED
L
IG
H T
PO
LE
D
IM
EN
SI
O N
S
N O
V
11/07/2023
AutoCAD SHX Text
SATISFACTORY TO
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text NOTES: 1. BATTERY: SELF CONTAINED BATTERY BACKUP UNIT BATTERY: SELF CONTAINED BATTERY BACKUP UNIT INCLUDED. 2. VA RATING: 550 VA VA RATING: 550 VA 3. INPUT VOLTAGE/CURRENT: 277V AT 2.5A. INPUT VOLTAGE/CURRENT: 277V AT 2.5A. 4. OUTPUT VOLTAGE/CURRENT: 277 VAC AT 1.99A. OUTPUT VOLTAGE/CURRENT: 277 VAC AT 1.99A. 5. OUTPUT PROTECTION: CIRCUIT BREAKER. OUTPUT PROTECTION: CIRCUIT BREAKER. 6. INVERTER SHALL BE WALL MOUNTED. INVERTER SHALL BE WALL MOUNTED. 7. PLENUM RATED AND UL LISTED. PLENUM RATED AND UL LISTED. 8. DIMENSION ARE APPROXIMATE. FINAL SIZING PER DIMENSION ARE APPROXIMATE. FINAL SIZING PER MANUFACTURER. 9. MINIMUM 90 MINUTES POWER SUPPLY. MINIMUM 90 MINUTES POWER SUPPLY. 10. OPERATING TEMPERATURE RANGE 20-30 DEGREE OPERATING TEMPERATURE RANGE 20-30 DEGREE CELSIUS MINIMUM.
AutoCAD SHX Text
DETECTABLE WARNING TAPE
AutoCAD SHX Text
BACKFILL COMPACTED
AutoCAD SHX Text 12"
AutoCAD SHX Text
24" MIN BELOW GRADE
AutoCAD SHX Text 3"
AutoCAD SHX Text 3"
AutoCAD SHX Text 3"
AutoCAD SHX Text
ES120
AutoCAD SHX Text 3"
AutoCAD SHX Text
FINISH GRADE
AutoCAD SHX Text 3"
AutoCAD SHX Text
2" PVC SCH-40 CONDUIT
AutoCAD SHX Text
CONCRETE ENCASEMENT
AutoCAD SHX Text
ES120
AutoCAD SHX Text
PROVIDE IN-LINE FUSE. SIZED PER MANUFACTURER SPEC.
AutoCAD SHX Text
PVC SCHEDULE 40 CONDUIT
AutoCAD SHX Text
#6 BARE COPPER, BOND
AutoCAD SHX Text
TO FOUNDATION REBAR
AutoCAD SHX Text
TO SOURCE OR
AutoCAD SHX Text
NEXT LIGHT
AutoCAD SHX Text
TAPERED ROUND CONCRETE POLE.
AutoCAD SHX Text
REMOVABLE BASE
AutoCAD SHX Text
COVER 2 PIECE
AutoCAD SHX Text
GALVANIZED CAST STEEL
AutoCAD SHX Text
ES120
AutoCAD SHX Text
AutoCAD SHX Text
ES121
AutoCAD SHX Text
CONCRETE POLE BASE
AutoCAD SHX Text
HOT DIPPED GALVANIZED STEEL ANCHOR BOLTS PER MANUFACTURER'S REQUIREMENT
AutoCAD SHX Text
FINISH GRADE
AutoCAD SHX Text
CONCRETE FOUNDATION PER SPECIFICATION 03 30 00
AutoCAD SHX Text
6" SQ #10/10 GALV REINF WIRE MESH, SINGLE WRAP
AutoCAD SHX Text TENON OPTION - 2-3/8 INCH TENON WITH PROVISION FOR WIRING. COORDINATE WITH LUMINARIES.
AutoCAD SHX Text NOTES: 1. WIND SPEED: 195 MPH WIND SPEED: 195 MPH 2. LATERAL PASSIVE EARTH PRESSURE: LATERAL PASSIVE EARTH PRESSURE: PER STRUCTURAL GENERAL NOTES 3. POLE BASE ANCHOR LAYOUT BY THE POLE BASE ANCHOR LAYOUT BY THE MANUFACTURER MUST HAVE A MAXIMUM DIAMETER LESS THAN THE FOUNDATION CAGE DIAMETER, AND MINIMUM OF 4 INCHES OF CONCRETE EDGE DISTANCE MUST BE MAINTAINED. 4. FOUNDATION DESIGN ASSUMES THERE FOUNDATION DESIGN ASSUMES THERE ARE NO SIGNS OF VOIDS IN THE IMMEDIATE VICINITY OF THE FOUNDATION AND GROUND WATER LEVEL IS AT LEAST 2 FEET BELOW THE FOUNDATION DEPTH. IF VOIDS OR GROUND WATER ARE ENCOUNTERED, CONTACT THE CONTRACTING OFFICER FOR FURTHER DIRECTION.
AutoCAD SHX Text WIRING HANDHOLE MINIMUM 2 1/2 INCH X 5 INCH CLEAR OPENING WITH COVER AND STAINLESS STEEL SCREWS.
AutoCAD SHX Text
FROM SOURCE OR PREVIOUS LIGHT
AutoCAD SHX Text
12" X 12" X 24" DEEP
AutoCAD SHX Text
HANDHOLE SIZING
AutoCAD SHX Text
REQUIRED
AutoCAD SHX Text
BOX WHEN
AutoCAD SHX Text
SECTIONAL
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
AutoCAD SHX Text
CRUSHED ROCK
AutoCAD SHX Text 6"
AutoCAD SHX Text
EARTH
AutoCAD SHX Text
COMPACTED
AutoCAD SHX Text
PULL SLOT
AutoCAD SHX Text
SURFACE
AutoCAD SHX Text
RESISTANT
AutoCAD SHX Text
SKID
AutoCAD SHX Text
LIGHTING
AutoCAD SHX Text
HEX BOLT AND
AutoCAD SHX Text
WASHER
AutoCAD SHX Text
STAINLESS STEEL
AutoCAD SHX Text
COVER
AutoCAD SHX Text
BOX AND
AutoCAD SHX Text
AROUND BOX
AutoCAD SHX Text 6"
AutoCAD SHX Text
CONCRETE RING
AutoCAD SHX Text 10"
AutoCAD SHX Text 6"
AutoCAD SHX Text
ES120
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
JKS
AutoCAD SHX Text
SAT
AutoCAD SHX Text
SEH
AutoCAD SHX Text
SEH
AutoCAD SHX Text
AutoCAD SHX Text 17302234
AutoCAD SHX Text
SITE LIGHTING PLAN
AutoCAD SHX Text
CONNECT LIGHT FIXTURE TO REMOTE DRIVER BY FOLLOWING MANUFACTURER GUIDANCE
AutoCAD SHX Text
TERMINATE CONDUIT INTERNALLY
AutoCAD SHX Text
ANGLE FIXTURE 20 DEGREE TOWARD THE SIGN MONUMENT
AutoCAD SHX Text
FIXTURE F14 (INSTALL PER MANUFACTURE GUIDANCE)
AutoCAD SHX Text
SIDE VIEW
AutoCAD SHX Text
TOP VIEW
AutoCAD SHX Text
INCOMING CONDUIT (POWER)
AutoCAD SHX Text
NEMA 4X STAINLESS STEEL 316 ENCLOSURE WITH REMOTE DRIVER
AutoCAD SHX Text
2" PVC SCH-80 CONDUIT
AutoCAD SHX Text
2" PVC SCH-80 CONDUIT
AutoCAD SHX Text
TRANSITION POINT FROM SCH-40 TO SCH-80.
AutoCAD SHX Text
PC
AutoCAD SHX Text
PHOTOCELL
AutoCAD SHX Text
48" MINIMUM BEND RADIUS
AutoCAD SHX Text NOTES: 1. ALL HARDWARE AND FASTENER SHALL ALL HARDWARE AND FASTENER SHALL USE 316 STAINLESS STEEL. 2. ENCLOSURES SHALL BE NEMA 4X 316 ENCLOSURES SHALL BE NEMA 4X 316 STAINLESS STEEL. 3. 4. REFER TO ARCHITECT DRAWINGS FOR REFER TO ARCHITECT DRAWINGS FOR ADDITIONAL DETAIL ON THE SIGN MONUMENT.
AutoCAD SHX Text
NEMA 4X STAINLESS STEEL 316 ENCLOSURE WITH REMOTE DRIVER
AutoCAD SHX Text
NEMA TYPE 1 ENCLOSURE
AutoCAD SHX Text
STATUS DISPLAY
AutoCAD SHX Text
ES120
AutoCAD SHX Text
#4 CIRCULAR TIES AT 12 INCH ON CENTER
AutoCAD SHX Text
8-#8 VERTICAL BARS EQUALLY SPACED
AutoCAD SHX Text
OUTLINE OF LIGHT POLE
AutoCAD SHX Text A
AutoCAD SHX Text
SECTION A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
| P406 Amendment 0003-Drawings-signed.pdf |
| P406 Amendment 0003 |
| S-551 MISCELLANEOUS DETAILS |
| A-601 DOOR SCHEDULE |
| EP118 FLOOR PLANS & ENLARGED DETAILS - CLERESTORY |
| ES121 SITE LIGHTING |
File details come from the government source that posted it. Updated .