24R1312_AMD0003.pdf

PDF 8 MB Posted

Attached to
FY24 MCON P-406, RECREATION CENTER, US NAVSUPPACT MCB GUAM, FINEGAYAN, GUAM
Solicitation number
N6274224R1312
Issued by

About this file

This document package includes construction drawings and specifications for a federal construction contract opportunity. The solicitation is for a FY24 Military Construction Project to build a new Recreation Center at the U.S. Naval Support Activity facility in Finegayan, Guam. The contract drawings show floor plans, elevations, and details for the building, including doors, windows, lighting and signage. Specification sections outline requirements for aluminum doors and frames, lighting, and site work. The opportunity is being conducted by the Naval Facilities Engineering Command Pacific for the Department of the Navy. The solicitation number is N6274224R1312. Responses are due in accordance with the revised schedule and drawings provided in Amendment 0003.

View the file

Other files

File Type Posted
24R1312_AMD08.pdf PDF
24R1312_AMD07.pdf PDF
P-406 DRAWINGS AMD06.pdf PDF
24R1312_AMD06.pdf PDF
24R1312 Note 7.pdf PDF
24R1312 Note 6.docx DOCX document
P-406 DRAWINGS AMD05.pdf PDF
241312_AMD05.pdf PDF
24R1312_AMD04.pdf PDF
24R1312 Note 5.pdf PDF
24R1312 Note 4.pdf PDF
24R1312 Note 3.pdf PDF
24R1312 Note 2.pdf PDF
24R1312_AMD02.pdf PDF
P-406 Site Visit Sign In Sheet.pdf PDF
24R1312_AMD01.pdf PDF
24R1312 Note 1.pdf PDF
3_P406 Drawings_Part2.pdf PDF
4_P406 Drawings_Part3.pdf PDF
24R1312-JA.ZIP ZIP file
2_P406 Drawings_Part1.pdf PDF
1_P406 Specs.pdf PDF
0_24R1312-RFP.pdf PDF
Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RFP No. N6274224R1312

Amendment No. 0003

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

The following items are applicable to this modification:

SPECIFICATIONS

SECTION 08 11 16 – ALUMINUM DOORS AND FRAMES

Remove Replace with

Page 5 Page 5

Amendment No. 0003

DRAWINGS

The following drawings supersede previously issued drawings bearing the same number and title:

DRAWING

NUMBER

NAVFAC

DRAWING

NUMBER

REVISION

NUMBER

DRAWING TITLE

S-551 17302033 1 MISCELLANEOUS DETAILS

A-601 17302080 1 DOOR SCHEDULE & NOTES

EP118 17302210 1 FLOOR PLANS & ENLARGED DETAILS - CLERESTORY

ES121 17302234 1 SITE LIGHTING PLAN

(End of Summary of Changes)

FY24 MCON P-406 RECREATION CENTER 1737348

US NAVSUPPORT MCB GUAM, FINEGAYAN, GUAM

of anchorage, glazing details, provisions for an location of hardware, mullion details, method and materials for flashing and weatherstripping, miscellaneous trim, installation details, and other related items necessary for a complete representation of all components.

1.5.2 Finish Samples

Submit two color charts and two finish sample chips from manufacturer's standard color and finish options for each type of finish indicated.

1.5.3 Operation and Maintenance Data

Submit detailed instructions for installation, adjustments, cleaning, and maintenance of each type of assembly indicated.

1.6 QUALITY ASSURANCE

PART 2 PRODUCTS

2.1 DOORS AND FRAMES

Provide heavy-duty swing-type aluminum doors and frames of size, design, and location indicated. Provide doors complete with frames, framing members, subframes, transoms, adjoining side lites , trim, and accessories. Coordinate side lites, with Section 08 41 13

ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS.

2.2 MATERIALS

2.2.1 Anchors

Type 316, stainless steel .

2.2.2 Weatherstripping

Continuous ultraviolet (UV) resistant, vinyl type recommended by door manufacturer.

2.2.3 Aluminum Alloy for Doors and Frames

ASTM B221M, ASTM B221, Alloy 6063-T5 for extrusions. ASTM B209M, ASTM B209, alloy and temper best suited for aluminum sheets and strips. Provide aluminum materials that include a minimum of 30 percent recycled content.

Provide data indicating percentage of recycled content of aluminum material.

2.2.4 Fasteners

Type 316, stainless steel.

2.2.5 Structural Steel

ASTM A36/A36M.

2.2.6 Aluminum Paint

Aluminum door manufacturer's standard aluminum paint.

SECTION 08 11 16 Page 5 Amendment 0003

11/07/2023

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

S

YS

TE

M

S C

O M

M

AN

D

DES DRW

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

DRAWFORM REVISION: 25 AUGUST 2020

CHK

OF

EPROJECT NO.:

DM

BRANCH MANAGER

CHIEF ENG

FIRE PROTECTION

A.

B.

C.

D.

E.

F.

G.

H.

MANUFACTURER'S NAME & NUMBERS SHOWN IN DETAILS ARE USED TO INDICATE

DESIRED DESIGN INTENT & REQUIREMENTS ONLY. PRODUCTS OF OTHER

MANUFACTURERS WHICH MEET THE SPECIFIED REQUIREMENTS OF THIS

CONTRACT MAY BE USED IF SIMILAR IN DESIGN & FUNCTION.

HOLLOW METAL DOOR FRAMES SHALL BE PACKED 100% FULL WITH MINERAL

WOOL. REFER TO DOOR DETAILS ON SHEETS A-501 AND A-502.

STC RATED DOOR ASSEMBLIES SHALL HAVE FRAME, PANEL AND SEALS PROVIDED BY

THE DOOR MANUFACTURER, AND TESTED AND ASSEMBLED BY A SINGLE

MANUFACTURER. SELF ADHESIVE SEALS ARE ONLY ACCEPTABLE FOR STC RATINGS

LESS THAN 45, AND ONLY IF 3-FIN OR 4-FIN TYPES ARE USED. COMPRESSION BULB

SEALS ARE NOT ACCEPTABLE UNLESS USED IN COMBINATION WITH OTHER SEAL

TYPES.

DOORS RATED STC 44 OR BELOW MAY BE SUPPLIED WITH A FRAME BY ANY

MANUFACTURER. DOORS RATED STC 45 OR ABOVE SHALL BE PROVIDED WITH

A FRAME PROVIDED BY THE DOOR MANUFACTURER, CONSISTED WITH THE

DOOR'S STC RATING.

COORDINATE ALL DOOR SECURITY HARDWARE SUCH THAT IT DOES NOT

INTERFERE WITH DOOR SEALS AT ANY LOCATION.

REFERENCE DOOR TYPES ON SHEET A-602, & DOOR DETAILS ON SHEETS

A-501.

REFER TO TECHNICAL SPECIFICATIONS (08 71 00) FOR DOOR

HARDWARE SCHEDULE

ALL EXTERIOR DOORS SHALL BE CAPABLE OF WITHSTANDING POSITIVE AND

NEGATIVE PRESSURE FROM 195 MPH WIND SPEED @ EXPOSURE C.

GENERAL NOTES

DOOR SCHEDULE REMARKS

CODE DESCRIPTION

DIMENSIONS GIVEN ARE FOR ENTIRE DOOR OPENING

REFERENCE RECESSED WALK OFF MAT ON DETAIL C3 SHEET A-703

SMOKE PARTITION DOOR

PROVIDE FIRE/SAFETY RATED GLASS

6 PROVIDE ELECTRIFIED LOCKSET, HINGE, OUTLET BOXES, AND CONDUITS AS

7 PROVIDE MANUAL LOCKSET

PROVIDE EXPLOSION-PROOF MOTOR

PROVIDE FULL PERIMETER ACOUSTICAL SEALS AND DOOR BOTTOM.

REFER TO HARDWARE SETS IN SPECIFICATION 08 71 00.

SPECIFIED IN SPECIFICATION 08 71 00 AND TELECOM DWGS.

PROVIDE WINDBORNE DEBRIS IMPACT-RESISTANT LAMINATED GLASS

PROVIDE EXIT DEVICE

11 PROVIDE DECORATIVE TREATMENT ON DOOR AND SIDELIGHT GLAZING.

DOOR SCHEDULE ABBREVIATIONS

AA ANODIZED ALUMNUM

AL ALUMINUM

CLR CLEAR

DBL DOUBLE

DR DOOR

FIN FINISH

FP FACTORY PAINTED

FRP FIBERGLASS REINFORCED POLYESTER

GALV GALVANIZED METAL

GS GALVANIZED STEEL

HDW HARDWARE

HM HOLLOW METAL

MATL MATERIAL

MIN MINIMUM

NO NUMBER

PU POLYURETHANE

PT PAINTED

SC SOLID CORE

SST STAINLESS STEEL

THK THICK

UL UNDERWRITERS LABORATORIES

WD WOOD

T TEMPERED

L LAMINATED

M METAL

IGU INSULATED-LAMINATED GLASS UNIT

FF FACTORY FINISHED

ESS ELECTRONICS SECURITY SYSTEM

STC SOUND TRANSMISSION CLASS

AS ACOUSTICAL SEAL

KEYING GROUPS

A

B

D E

C

CODE DESCRIPTION

GENERAL BUILDING ACCESS FROM EXTERIOR (WORKERS USE IT TO GET INTO

BUILDING PRIOR OR AFTER WORKING HOURS.)

GENERAL INTERIOR BUILDING ACCESS (WORKERS USE IT TO GET INTO MAIN

BUILDING SPACE DURING WORKING HOURS.)

PRIVATE OFFICE

CARD KEY ACCESS - UTILITY ROOMS

X EXTERIOR GATES. ASSUMING PADLOCKS WHICH MAY HAVE THEIR OWN KEYS.

CARD KEY ACCESS - SENSITIVE AREAS (GTR)

17302080

A-601

D O

O R

S C

H E

D U

LE

N O

TE

S

11/07/2023

AutoCAD SHX Text

SATISFACTORY TO

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

FOR COMMANDER NAVFAC

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

A/E INFO

AutoCAD SHX Text

AS NOTED

AutoCAD SHX Text

EE

AutoCAD SHX Text

JV

AutoCAD SHX Text

NK

AutoCAD SHX Text

03 NOV 2023

AutoCAD SHX Text

AMENDMENT 0003 - REVISE DOOR SCHEDULE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

S

YS

TE

M

S C

O M

M

AN

D

DES DRW

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

DRAWFORM REVISION: 25 AUGUST 2020

CHK

OF

EPROJECT NO.:

DM

BRANCH MANAGER

CHIEF ENG

FIRE PROTECTION

NA

VF

AC

P

AC

IF

IC

NA

VF

AC

P

AC

IF

IC

MA

KA

LA

PA

, H

AW

AI

I

US

N

AV

SU

PP

AC

T M

CB

G

UA

M

FI

NE

G

AY

AN

, G

UA

M

FY

M

CO

N P-

RE

CR

EA

TI

O N

CE

NT

ER

08/22/2023

MPU

BMC

JCC

1737348

APPROVED BY RANDALL TORIGOE,

MILCON PLANNER, DPP-H

VIA EMAIL

POWER - EXTERIOR ELEVATION - SOUTH - CLERSTORY

SCALE: 3/16"=1'-0" 1EP111

A. PROVIDE 24"X24" ACCESS PANEL TO ALL STORM SHUTTER AND

ROLLER SHADE DISCONNECTS. SEE D2/A521 FOR DETAILS.

B. MOTOR AND DISCONNECTS SHOWN ARE NOTATIONAL, LOCATE

NEARBY DISCONNECTS SO THAT ACCESS PANELS MAY BE SHARED.

C. ELECTRICAL EQUIPMENT SHOWN ON EXTERIOR ELEVATIONS FOR

ILLUSTRATION PURPOSES ONLY. ALL EQUIPMENT TO BE INSTALLED

ON INTERIOR OF BUILDING.

D. LIGHTNING PROTECTION AIR TERMINALS SHOWN ARE FOR

ILLUSTRATION PURPOSES ONLY.

1. NA

W 2M1-2

ABV

2M1-14

ABV

2M1-12

ABV

2M1-10

ABV

2M1-8

ABV

2M1-6

ABV

2M1-4

ABV

2M1-2

ABV

2M1-4

ABV

2M1-6

ABV

2M1-8

ABV

2M1-10

ABV

2M1-12

ABV

2M1-14

TO CUSTOMER

SERVICE STORM

SHUTTER CONTROL

TO CUSTOMER

SERVICE ROLLER

SHADE CONTROL

TO CUSTOMER

SERVICE ROLLER

SHADE CONTROL

FL

O

O R

P

LA

N S

E

N

LA

R G

E D

D E

TA

IL

S

C

LE

R E

S

TO

R Y

EP118

JKS

AC

C

ES

S

PA

N

EL

S

IZ

E

C

LA

R

IF

IC

AT

IO

N

N

O V

11/07/2023

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text

SATISFACTORY TO

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

FOR COMMANDER NAVFAC

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

A/E INFO

AutoCAD SHX Text

PLAN NORTH

AutoCAD SHX Text

TRUE NORTH

AutoCAD SHX Text 8'

AutoCAD SHX Text 12'

AutoCAD SHX Text 4'

AutoCAD SHX Text

SCALE: 3/16" = 1'-0"

AutoCAD SHX Text 4'

AutoCAD SHX Text 0'

AutoCAD SHX Text 2'

AutoCAD SHX Text X

AutoCAD SHX Text 17302210

AutoCAD SHX Text

AutoCAD SHX Text

BZL

AutoCAD SHX Text

BZL

AutoCAD SHX Text

SAT

AutoCAD SHX Text

11/7/2023 8:40 AM

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

S

YS

TE

M

S C

O M

M

AN

D

DES DRW

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

DRAWFORM REVISION: 25 AUGUST 2020

CHK

OF

EPROJECT NO.:

DM

BRANCH MANAGER

CHIEF ENG

FIRE PROTECTION

NA

VF

AC

P

AC

IF

IC

NA

VF

AC

P

AC

IF

IC

MA

KA

LA

PA

, H

AW

AI

I

US

N

AV

SU

PP

AC

T M

CB

G

UA

M

FI

NE

G

AY

AN

, G

UA

M

FY

M

CO

N P-

RE

CR

EA

TI

O N

CE

NT

ER

08/22/2023

MPU

BMC

JCC

1737348

APPROVED BY RANDALL TORIGOE,

MILCON PLANNER, DPP-H

VIA EMAIL

INVERTER FOR EXTERIOR LIGHTS

SCALE: NO SCALE

TRENCH DETAIL (TYPICAL)

SCALE: NO SCALE 3 2

LIGHT POLE DETAIL

SCALE: NO SCALE 1

FT

8F T

3F T

" M

IN

LIGHTING HANDHOLE DETAIL

SCALE: NTS 4

NOTES:

1. HOUSING SHALL BE POLYMER

CONCRETE REINFORCED WITH A HEAVY

WEAVE FIBERGLASS REINFORCING

WITH COMPRESSIVE STRENGTH OF

LESS THAN 10,000 PSI.

2. COVER AND BOX SHALL WITHSTAND A

SERVICE LOAD OF LESS THAN 15,000

LBS OVER A 10" X 10" AREA.

3. PROVIDE STAINLESS STEEL BOLTS AND

INSERTS.

4. PROVIDE WITH (2) 2 1/2" MOUSEHOLES.

ES121

MONUMENT SIGN DETAIL

SCALE: NO SCALE 5

2FT

5.5

FT

R

EV

IS

ED

L

IG

H T

PO

LE

D

IM

EN

SI

O N

S

N O

V

11/07/2023

AutoCAD SHX Text

SATISFACTORY TO

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

FOR COMMANDER NAVFAC

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

A/E INFO

AutoCAD SHX Text NOTES: 1. BATTERY: SELF CONTAINED BATTERY BACKUP UNIT BATTERY: SELF CONTAINED BATTERY BACKUP UNIT INCLUDED. 2. VA RATING: 550 VA VA RATING: 550 VA 3. INPUT VOLTAGE/CURRENT: 277V AT 2.5A. INPUT VOLTAGE/CURRENT: 277V AT 2.5A. 4. OUTPUT VOLTAGE/CURRENT: 277 VAC AT 1.99A. OUTPUT VOLTAGE/CURRENT: 277 VAC AT 1.99A. 5. OUTPUT PROTECTION: CIRCUIT BREAKER. OUTPUT PROTECTION: CIRCUIT BREAKER. 6. INVERTER SHALL BE WALL MOUNTED. INVERTER SHALL BE WALL MOUNTED. 7. PLENUM RATED AND UL LISTED. PLENUM RATED AND UL LISTED. 8. DIMENSION ARE APPROXIMATE. FINAL SIZING PER DIMENSION ARE APPROXIMATE. FINAL SIZING PER MANUFACTURER. 9. MINIMUM 90 MINUTES POWER SUPPLY. MINIMUM 90 MINUTES POWER SUPPLY. 10. OPERATING TEMPERATURE RANGE 20-30 DEGREE OPERATING TEMPERATURE RANGE 20-30 DEGREE CELSIUS MINIMUM.

AutoCAD SHX Text

DETECTABLE WARNING TAPE

AutoCAD SHX Text

BACKFILL COMPACTED

AutoCAD SHX Text 12"

AutoCAD SHX Text

24" MIN BELOW GRADE

AutoCAD SHX Text 3"

AutoCAD SHX Text 3"

AutoCAD SHX Text 3"

AutoCAD SHX Text

ES120

AutoCAD SHX Text 3"

AutoCAD SHX Text

FINISH GRADE

AutoCAD SHX Text 3"

AutoCAD SHX Text

2" PVC SCH-40 CONDUIT

AutoCAD SHX Text

CONCRETE ENCASEMENT

AutoCAD SHX Text

ES120

AutoCAD SHX Text

PROVIDE IN-LINE FUSE. SIZED PER MANUFACTURER SPEC.

AutoCAD SHX Text

PVC SCHEDULE 40 CONDUIT

AutoCAD SHX Text

#6 BARE COPPER, BOND

AutoCAD SHX Text

TO FOUNDATION REBAR

AutoCAD SHX Text

TO SOURCE OR

AutoCAD SHX Text

NEXT LIGHT

AutoCAD SHX Text

TAPERED ROUND CONCRETE POLE.

AutoCAD SHX Text

REMOVABLE BASE

AutoCAD SHX Text

COVER 2 PIECE

AutoCAD SHX Text

GALVANIZED CAST STEEL

AutoCAD SHX Text

ES120

AutoCAD SHX Text

AutoCAD SHX Text

ES121

AutoCAD SHX Text

CONCRETE POLE BASE

AutoCAD SHX Text

HOT DIPPED GALVANIZED STEEL ANCHOR BOLTS PER MANUFACTURER'S REQUIREMENT

AutoCAD SHX Text

FINISH GRADE

AutoCAD SHX Text

CONCRETE FOUNDATION PER SPECIFICATION 03 30 00

AutoCAD SHX Text

6" SQ #10/10 GALV REINF WIRE MESH, SINGLE WRAP

AutoCAD SHX Text TENON OPTION - 2-3/8 INCH TENON WITH PROVISION FOR WIRING. COORDINATE WITH LUMINARIES.

AutoCAD SHX Text NOTES: 1. WIND SPEED: 195 MPH WIND SPEED: 195 MPH 2. LATERAL PASSIVE EARTH PRESSURE: LATERAL PASSIVE EARTH PRESSURE: PER STRUCTURAL GENERAL NOTES 3. POLE BASE ANCHOR LAYOUT BY THE POLE BASE ANCHOR LAYOUT BY THE MANUFACTURER MUST HAVE A MAXIMUM DIAMETER LESS THAN THE FOUNDATION CAGE DIAMETER, AND MINIMUM OF 4 INCHES OF CONCRETE EDGE DISTANCE MUST BE MAINTAINED. 4. FOUNDATION DESIGN ASSUMES THERE FOUNDATION DESIGN ASSUMES THERE ARE NO SIGNS OF VOIDS IN THE IMMEDIATE VICINITY OF THE FOUNDATION AND GROUND WATER LEVEL IS AT LEAST 2 FEET BELOW THE FOUNDATION DEPTH. IF VOIDS OR GROUND WATER ARE ENCOUNTERED, CONTACT THE CONTRACTING OFFICER FOR FURTHER DIRECTION.

AutoCAD SHX Text WIRING HANDHOLE MINIMUM 2 1/2 INCH X 5 INCH CLEAR OPENING WITH COVER AND STAINLESS STEEL SCREWS.

AutoCAD SHX Text

FROM SOURCE OR PREVIOUS LIGHT

AutoCAD SHX Text

12" X 12" X 24" DEEP

AutoCAD SHX Text

HANDHOLE SIZING

AutoCAD SHX Text

REQUIRED

AutoCAD SHX Text

BOX WHEN

AutoCAD SHX Text

SECTIONAL

AutoCAD SHX Text

TYPE

AutoCAD SHX Text

AutoCAD SHX Text

CRUSHED ROCK

AutoCAD SHX Text 6"

AutoCAD SHX Text

EARTH

AutoCAD SHX Text

COMPACTED

AutoCAD SHX Text

PULL SLOT

AutoCAD SHX Text

SURFACE

AutoCAD SHX Text

RESISTANT

AutoCAD SHX Text

SKID

AutoCAD SHX Text

LIGHTING

AutoCAD SHX Text

HEX BOLT AND

AutoCAD SHX Text

WASHER

AutoCAD SHX Text

STAINLESS STEEL

AutoCAD SHX Text

COVER

AutoCAD SHX Text

BOX AND

AutoCAD SHX Text

AROUND BOX

AutoCAD SHX Text 6"

AutoCAD SHX Text

CONCRETE RING

AutoCAD SHX Text 10"

AutoCAD SHX Text 6"

AutoCAD SHX Text

ES120

AutoCAD SHX Text

AS NOTED

AutoCAD SHX Text

JKS

AutoCAD SHX Text

SAT

AutoCAD SHX Text

SEH

AutoCAD SHX Text

SEH

AutoCAD SHX Text

AutoCAD SHX Text 17302234

AutoCAD SHX Text

SITE LIGHTING PLAN

AutoCAD SHX Text

CONNECT LIGHT FIXTURE TO REMOTE DRIVER BY FOLLOWING MANUFACTURER GUIDANCE

AutoCAD SHX Text

TERMINATE CONDUIT INTERNALLY

AutoCAD SHX Text

ANGLE FIXTURE 20 DEGREE TOWARD THE SIGN MONUMENT

AutoCAD SHX Text

FIXTURE F14 (INSTALL PER MANUFACTURE GUIDANCE)

AutoCAD SHX Text

SIDE VIEW

AutoCAD SHX Text

TOP VIEW

AutoCAD SHX Text

INCOMING CONDUIT (POWER)

AutoCAD SHX Text

NEMA 4X STAINLESS STEEL 316 ENCLOSURE WITH REMOTE DRIVER

AutoCAD SHX Text

2" PVC SCH-80 CONDUIT

AutoCAD SHX Text

2" PVC SCH-80 CONDUIT

AutoCAD SHX Text

TRANSITION POINT FROM SCH-40 TO SCH-80.

AutoCAD SHX Text

PC

AutoCAD SHX Text

PHOTOCELL

AutoCAD SHX Text

48" MINIMUM BEND RADIUS

AutoCAD SHX Text NOTES: 1. ALL HARDWARE AND FASTENER SHALL ALL HARDWARE AND FASTENER SHALL USE 316 STAINLESS STEEL. 2. ENCLOSURES SHALL BE NEMA 4X 316 ENCLOSURES SHALL BE NEMA 4X 316 STAINLESS STEEL. 3. 4. REFER TO ARCHITECT DRAWINGS FOR REFER TO ARCHITECT DRAWINGS FOR ADDITIONAL DETAIL ON THE SIGN MONUMENT.

AutoCAD SHX Text

NEMA 4X STAINLESS STEEL 316 ENCLOSURE WITH REMOTE DRIVER

AutoCAD SHX Text

NEMA TYPE 1 ENCLOSURE

AutoCAD SHX Text

STATUS DISPLAY

AutoCAD SHX Text

ES120

AutoCAD SHX Text

#4 CIRCULAR TIES AT 12 INCH ON CENTER

AutoCAD SHX Text

8-#8 VERTICAL BARS EQUALLY SPACED

AutoCAD SHX Text

OUTLINE OF LIGHT POLE

AutoCAD SHX Text A

AutoCAD SHX Text

SECTION A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

P406 Amendment 0003-Drawings-signed.pdf
P406 Amendment 0003
S-551 MISCELLANEOUS DETAILS
A-601 DOOR SCHEDULE
EP118 FLOOR PLANS & ENLARGED DETAILS - CLERESTORY
ES121 SITE LIGHTING

File details come from the government source that posted it. Updated .