24R1312_AMD07.pdf
PDF 7 MB Posted
- Solicitation number
- N6274224R1312
About this file
This document package includes construction drawings and specifications for a federal solicitation to build a recreation center. Key details include the solicitation number N6274224R1312 issued by the Naval Facilities Engineering Command for the FY24 MCON P-406 Recreation Center at the US Naval Supply Systems Command in Finegayan, Guam. The package contains over 20 architectural and engineering drawings detailing site plans, floor plans, elevations, sections and construction details. Specifications cover requirements for electrical systems, lighting, communications, security and building automation. Submissions are due by the date specified in Amendment 7. The scope of work entails design and construction of a new recreation facility including game rooms, fitness areas, outdoor spaces and support spaces.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 24R1312_AMD08.pdf | ||
| P-406 DRAWINGS AMD06.pdf | ||
| 24R1312_AMD06.pdf | ||
| 24R1312 Note 7.pdf | ||
| 24R1312 Note 6.docx | DOCX document | |
| P-406 DRAWINGS AMD05.pdf | ||
| 241312_AMD05.pdf | ||
| 24R1312_AMD04.pdf | ||
| 24R1312 Note 5.pdf | ||
| 24R1312 Note 4.pdf | ||
| 24R1312 Note 3.pdf | ||
| 24R1312_AMD0003.pdf | ||
| 24R1312 Note 2.pdf | ||
| 24R1312_AMD02.pdf | ||
| P-406 Site Visit Sign In Sheet.pdf | ||
| 24R1312_AMD01.pdf | ||
| 24R1312 Note 1.pdf | ||
| 3_P406 Drawings_Part2.pdf | ||
| 4_P406 Drawings_Part3.pdf | ||
| 24R1312-JA.ZIP | ZIP file | |
| 2_P406 Drawings_Part1.pdf | ||
| 1_P406 Specs.pdf | ||
| 0_24R1312-RFP.pdf |
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
RFP N62742-24-R-1312, NAVFAC WON 1737348, FY24 MCON P-406 RECREATION CENTER, US NAVSUPPACT MCB, GUAM, FINEGAYAN, GUAM
Amendment No. 0007 is continued on page 2.
1. CONTRACT ID CODE PAGE OF PAGES
1 1
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X N6274224R1312
X 9B. DATED (SEE ITEM 11)
26-Sep-2023
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO.
5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
13-Dec-2023
CODE
NAVFAC PACIFIC
CONSTRUCTION CONTRACTS BR (CODE ACQ33)
258 MAKALAPA DR STE 100
PEARL HARBOR HI 96860-3134
N62742 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
RFP No. N6274224R1312 Amendment No. 0007
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
The following items are applicable to this modification:
DRAWINGS
The following previously issued drawings shall be deleted in its entirety and replaced with the attached signed drawings bearing the same number and title. No revisions to the drawings were made in this Amendment.
DRAWING
NUMBER
NAVFAC
DRAWING
NUMBER
DRAWING TITLE
A-846 17302099 INTERIOR ELEVATIONS & PARTIAL EXTERIOR
ELEVATIONS
S-551 17302033 MISCELLANEOUS DETAILS
A-601 17302080 DOOR SCHEDULE & NOTES
EP118 17302210 FLOOR PLANS & ENLARGED DETAILS -
CLERESTORY
ES121 17302234 SITE LIGHTING PLAN
G-002 17301952 SHEET INDEX
GC101 17301963 OVERALL LOCATION PLAN & HAUL ROUTE
GC502 17301966 BEDROCK DETERMINATION MAP
E-001 17302188 LEGEND AND SHEET LIST
E-607 17302199 PANEL SCHEDULE 208V - GTR, CTR, AV
EP113 17302205 FLOOR PLANS & ENLARGED DETAILS – AREA B
EP114 17302206 FLOOR PLANS & ENLARGED DETAILS – CTR &
GTR
B CA D
121 COMPUTER AREA
B CA D
122 TV LOUNGE/ LIBRARY/ QUIET AREA
BBQ/COOKING
AREA
A DC
PROPANE
NO SMOKING
2 0
B
123 COVERED
OUTDOOR
GATHERING AREA
B
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
OF
EPROJECT NO.:
DM
BRANCH MANAGER
CHIEF ENG
FIRE PROTECTION
1/4" = 1'-0"
1/4" = 1'-0"
17302099
A-846
IN
TE
R
IO
R E
LE
V
A
TI
O N
S
P A
R
TI
A L
E X
TE
R
IO
R
E
LE
V A
TI
O
N S
10/10/2023
11/07/2023
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
OF
EPROJECT NO.:
DM
BRANCH MANAGER
CHIEF ENG
FIRE PROTECTION
A.
B.
C.
D.
E.
F.
G.
H.
MANUFACTURER'S NAME & NUMBERS SHOWN IN DETAILS ARE USED TO INDICATE
DESIRED DESIGN INTENT & REQUIREMENTS ONLY. PRODUCTS OF OTHER
MANUFACTURERS WHICH MEET THE SPECIFIED REQUIREMENTS OF THIS
CONTRACT MAY BE USED IF SIMILAR IN DESIGN & FUNCTION.
HOLLOW METAL DOOR FRAMES SHALL BE PACKED 100% FULL WITH MINERAL
WOOL. REFER TO DOOR DETAILS ON SHEETS A-501 AND A-502.
STC RATED DOOR ASSEMBLIES SHALL HAVE FRAME, PANEL AND SEALS PROVIDED BY
THE DOOR MANUFACTURER, AND TESTED AND ASSEMBLED BY A SINGLE
MANUFACTURER. SELF ADHESIVE SEALS ARE ONLY ACCEPTABLE FOR STC RATINGS
LESS THAN 45, AND ONLY IF 3-FIN OR 4-FIN TYPES ARE USED. COMPRESSION BULB
SEALS ARE NOT ACCEPTABLE UNLESS USED IN COMBINATION WITH OTHER SEAL
TYPES.
DOORS RATED STC 44 OR BELOW MAY BE SUPPLIED WITH A FRAME BY ANY
MANUFACTURER. DOORS RATED STC 45 OR ABOVE SHALL BE PROVIDED WITH
A FRAME PROVIDED BY THE DOOR MANUFACTURER, CONSISTED WITH THE
DOOR'S STC RATING.
COORDINATE ALL DOOR SECURITY HARDWARE SUCH THAT IT DOES NOT
INTERFERE WITH DOOR SEALS AT ANY LOCATION.
REFERENCE DOOR TYPES ON SHEET A-602, & DOOR DETAILS ON SHEETS
A-501.
REFER TO TECHNICAL SPECIFICATIONS (08 71 00) FOR DOOR
HARDWARE SCHEDULE
ALL EXTERIOR DOORS SHALL BE CAPABLE OF WITHSTANDING POSITIVE AND
NEGATIVE PRESSURE FROM 195 MPH WIND SPEED @ EXPOSURE C.
GENERAL NOTES
DOOR SCHEDULE REMARKS
CODE DESCRIPTION
DIMENSIONS GIVEN ARE FOR ENTIRE DOOR OPENING
REFERENCE RECESSED WALK OFF MAT ON DETAIL C3 SHEET A-703
SMOKE PARTITION DOOR
PROVIDE FIRE/SAFETY RATED GLASS
6 PROVIDE ELECTRIFIED LOCKSET, HINGE, OUTLET BOXES, AND CONDUITS AS
7 PROVIDE MANUAL LOCKSET
PROVIDE EXPLOSION-PROOF MOTOR
PROVIDE FULL PERIMETER ACOUSTICAL SEALS AND DOOR BOTTOM.
REFER TO HARDWARE SETS IN SPECIFICATION 08 71 00.
SPECIFIED IN SPECIFICATION 08 71 00 AND TELECOM DWGS.
PROVIDE WINDBORNE DEBRIS IMPACT-RESISTANT LAMINATED GLASS
PROVIDE EXIT DEVICE
11 PROVIDE DECORATIVE TREATMENT ON DOOR AND SIDELIGHT GLAZING.
DOOR SCHEDULE ABBREVIATIONS
AA ANODIZED ALUMNUM
AL ALUMINUM
CLR CLEAR
DBL DOUBLE
DR DOOR
FIN FINISH
FP FACTORY PAINTED
FRP FIBERGLASS REINFORCED POLYESTER
GALV GALVANIZED METAL
GS GALVANIZED STEEL
HDW HARDWARE
HM HOLLOW METAL
MATL MATERIAL
MIN MINIMUM
NO NUMBER
PU POLYURETHANE
PT PAINTED
SC SOLID CORE
SST STAINLESS STEEL
THK THICK
UL UNDERWRITERS LABORATORIES
WD WOOD
T TEMPERED
L LAMINATED
M METAL
IGU INSULATED-LAMINATED GLASS UNIT
FF FACTORY FINISHED
ESS ELECTRONICS SECURITY SYSTEM
STC SOUND TRANSMISSION CLASS
AS ACOUSTICAL SEAL
KEYING GROUPS
A
B
D E
C
CODE DESCRIPTION
GENERAL BUILDING ACCESS FROM EXTERIOR (WORKERS USE IT TO GET INTO
BUILDING PRIOR OR AFTER WORKING HOURS.)
GENERAL INTERIOR BUILDING ACCESS (WORKERS USE IT TO GET INTO MAIN
BUILDING SPACE DURING WORKING HOURS.)
PRIVATE OFFICE
CARD KEY ACCESS - UTILITY ROOMS
X EXTERIOR GATES. ASSUMING PADLOCKS WHICH MAY HAVE THEIR OWN KEYS.
CARD KEY ACCESS - SENSITIVE AREAS (GTR)
17302080
A-601
D O
O R
S C
H E
D U
LE
N O
TE
S
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
OF
EPROJECT NO.:
DM
BRANCH MANAGER
CHIEF ENG
FIRE PROTECTION
NA
VF
AC
P
AC
IF
IC
NA
VF
AC
P
AC
IF
IC
MA
KA
LA
PA
, H
AW
AI
I
US
N
AV
SU
PP
AC
T M
CB
G
UA
M
FI
NE
G
AY
AN
, G
UA
M
FY
M
CO
N P-
RE
CR
EA
TI
O N
CE
NT
ER
08/22/2023
MPU
BMC
JCC
1737348
APPROVED BY RANDALL TORIGOE,
MILCON PLANNER, DPP-H
VIA EMAIL
POWER - EXTERIOR ELEVATION - SOUTH - CLERSTORY
SCALE: 3/16"=1'-0" 1EP111
A. PROVIDE 24"X24" ACCESS PANEL TO ALL STORM SHUTTER AND
ROLLER SHADE DISCONNECTS. SEE D2/A521 FOR DETAILS.
B. MOTOR AND DISCONNECTS SHOWN ARE NOTATIONAL, LOCATE
NEARBY DISCONNECTS SO THAT ACCESS PANELS MAY BE SHARED.
C. ELECTRICAL EQUIPMENT SHOWN ON EXTERIOR ELEVATIONS FOR
ILLUSTRATION PURPOSES ONLY. ALL EQUIPMENT TO BE INSTALLED
ON INTERIOR OF BUILDING.
D. LIGHTNING PROTECTION AIR TERMINALS SHOWN ARE FOR
ILLUSTRATION PURPOSES ONLY.
1. NA
W 2M1-2
ABV
2M1-14
ABV
2M1-12
ABV
2M1-10
ABV
2M1-8
ABV
2M1-6
ABV
2M1-4
ABV
2M1-2
ABV
2M1-4
ABV
2M1-6
ABV
2M1-8
ABV
2M1-10
ABV
2M1-12
ABV
2M1-14
TO CUSTOMER
SERVICE STORM
SHUTTER CONTROL
TO CUSTOMER
SERVICE ROLLER
SHADE CONTROL
TO CUSTOMER
SERVICE ROLLER
SHADE CONTROL
FL
O
O R
P
LA
N S
E
N
LA
R G
E D
D E
TA
IL
S
C
LE
R E
S
TO
R Y
EP118
JKS
AC
C
ES
S
PA
N
EL
S
IZ
E
C
LA
R
IF
IC
AT
IO
N
N
O V
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
OF
EPROJECT NO.:
DM
BRANCH MANAGER
CHIEF ENG
FIRE PROTECTION
NA
VF
AC
P
AC
IF
IC
NA
VF
AC
P
AC
IF
IC
MA
KA
LA
PA
, H
AW
AI
I
US
N
AV
SU
PP
AC
T M
CB
G
UA
M
FI
NE
G
AY
AN
, G
UA
M
FY
M
CO
N P-
RE
CR
EA
TI
O N
CE
NT
ER
08/22/2023
MPU
BMC
JCC
1737348
APPROVED BY RANDALL TORIGOE,
MILCON PLANNER, DPP-H
VIA EMAIL
INVERTER FOR EXTERIOR LIGHTS
SCALE: NO SCALE
TRENCH DETAIL (TYPICAL)
SCALE: NO SCALE 3 2
LIGHT POLE DETAIL
SCALE: NO SCALE 1
FT
8F T
3F T
" M
IN
LIGHTING HANDHOLE DETAIL
SCALE: NTS 4
NOTES:
1. HOUSING SHALL BE POLYMER
CONCRETE REINFORCED WITH A HEAVY
WEAVE FIBERGLASS REINFORCING
WITH COMPRESSIVE STRENGTH OF
LESS THAN 10,000 PSI.
2. COVER AND BOX SHALL WITHSTAND A
SERVICE LOAD OF LESS THAN 15,000
LBS OVER A 10" X 10" AREA.
3. PROVIDE STAINLESS STEEL BOLTS AND
INSERTS.
4. PROVIDE WITH (2) 2 1/2" MOUSEHOLES.
ES121
MONUMENT SIGN DETAIL
SCALE: NO SCALE 5
2FT
5.5
FT
R
EV
IS
ED
L
IG
H T
PO
LE
D
IM
EN
SI
O N
S
N O
V
NAVFAC
NO.
DWG
NO. REV TITLENO.
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
OF
EPROJECT NO.:
DM
BRANCH MANAGER
CHIEF ENG
FIRE PROTECTION
DRAWING INDEX
NAVFAC
NO.
DWG
NO. REV TITLENO. NAVFAC
NO.
DWG
NO. REV TITLENO.
S H
E E
T
IN
D E
X
G-002
11/15/2023
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
OF
EPROJECT NO.:
DM
BRANCH MANAGER
CHIEF ENG
FIRE PROTECTION
GC101
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
OF
EPROJECT NO.:
DM
BRANCH MANAGER
CHIEF ENG
FIRE PROTECTION
GC502
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
OF
EPROJECT NO.:
DM
BRANCH MANAGER
CHIEF ENG
FIRE PROTECTION
NA
VF
AC
P
AC
IF
IC
NA
VF
AC
P
AC
IF
IC
MA
KA
LA
PA
, H
AW
AI
I
US
N
AV
SU
PP
AC
T M
CB
G
UA
M
FI
NE
G
AY
AN
, G
UA
M
FY
M
CO
N P-
RE
CR
EA
TI
O N
CE
NT
ER
08/22/2023
MPU
BMC
JCC
1737348
APPROVED BY RANDALL TORIGOE,
MILCON PLANNER, DPP-H
VIA EMAIL
BACKGROUND
NEW TELECOMMUNICATION OR LIGHTING EQUIPMENT SHOWN
FOR REFERENCE, SEE ETXXX AND ELXXX PLANS DEVICE
NEW ELECTRICAL DEVICE
LINE WEIGHTS:
EQUIPMENT TO BE REMOVED
RC-10
RECEPTACLE, TYPICAL
"PB1" INDICATES POWER SOURCE, WHEN SHOWN
"4" INDICATES CIRCUIT NUMBER.
KEY NOTE #X. SEE ASSOCIATED NOTE ON SAME SHEET.
REVISION #X. SEE ASSOCIATED REVISION NOTE.
PHOTO OR ELEVATIONS INDICATOR
DRAWING TITLE INDICATOR
REVISION CLOUD AND NUMBER INDICATOR
LOCATED ON
DIRECTION OF CUTTING PLANE
NUMBER
CALL BACK
REVISION NUMBER
DRAWING VIEW TITLE
LIMIT OF REVISION AREA
DRAWING VIEW SCALE
DRAWING VIEW #
TITLE
SCALE #XXXX
CIRCUIT BREAKER, NUMBER OF POLES, FRAME AND TRIP RATINGS AS INDICATED
TRANSFORMER, RATINGS AND TYPE AS INDICATED
MOTOR
GROUND, SEE NEUTRAL GROUND DIAGRAM
UTILITY FEEDER LINE, FEEDER 581 (ONE-LINE)
PANELBOARD, SHADING INDICATES WORKING SPACE
GROUND ROD IN GROUND WELL, SEE DETAIL 1, EG-501
T
1' x 1' GRID SCALING
ENCLOSED CIRCUIT BREAKER "GMS" OR "MS"
SIZE AS INDICATED. BOTTOM OF EQUIPMENT TO NOT BE MORE THAN +27" AFF.
NON-FUSIBLE MOTOR RATED DISCONNECT, SWITCH RATING AS INDICATED.
PROVIDE MOTOR RATED TOGGLE SWITCH IF NO RATINGS ARE INDICATED
FUSE
GROUNDING/BONDING BUSBAR, MOUNTED +18" AFF
EQUIPMENT CONNECTION, CEILING/FLOOR MOUNTED
JUNCTION BOX FOR EQUIPMENT CONNECTION, CEILING/FLOOR MOUNTED. (W INDICATES
RECESSED IN WALL, WHERE POSSIBLE) COORDINATE MOUNTING HEIGHT WITH EQUIPMENT
INSTALLER
POWER REFERENCE GENERAL CIRCUITING
ENLARGED DETAIL/AREA INDICATOR
DETAIL NUMBER
LOCATED ON
LIMIT OF ENLARGED AREA
DUPLEX RECEPTACLE: 125V, 20A, 18" ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED
QUADRUPLEX RECEPTACLES: 125V, 20A, 18" ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED
RECESSED FLOOR DUPLEX/QUADRUPLEX RECEPTACLE. NEMA 5-20R
NEMA 5-20R.
NEMA 5-20R.
AIR TERMINAL , SEE DETAIL C1, EG-500
JUNCTION BOX DEDICATED FOR DIGITAL CLOCK, REFER TO INTERIOR DRAWINGS FOR CEQ MOUNTING HEIGHTS.
COORDINATE LOCATION WITH EQUIPMENT INSTALLER.
:INDICATES NEW CONDUCTOR IN DUCT BANK.
:INDICATES DEMOLITION OF EXISTING FEEDER &
INSTALLATION OF NEW FEEDER IN EXISTING
DUCT BANK.
:INDICATES EXISTING CONDUCTOR IN DUCT
BANK.
P581 :INDICATES CONDUCTOR DESTINATION
AVAILABLE FAULT CURRENT AT LOCATION INDICATED
DISCONNECT TOGGLE SWITCH
:INDICATES DIRECTION OF VIEW.
:INDICATES SPARE CONDUIT.
ALL CONDUIT IS 4" UNLESS OTHERWISE NOTED
WIRING SUBSCRIPT:
C = CEILING MOUNTED
W = WALL MOUNTED
S = SURFACE MOUNTED
GFCI = GROUND FAULT CIRCUIT INTERRUPTER
IG = ISOLATED GROUND
WP = WEATHERPROOF COVER WITH WEATHER-RESISTANT RECEPTACLE
UC = UNDER COUNTER,
ABV = ABOVE CEILING, COORDINATE MOUNTING HEIGHT WITH EQUIPMENT INSTALLER
AC = ABOVE COUNTER BACK-SPLASH, COORDINATE MOUNTING HEIGHT WITH EQUIPMENT INSTALLER a = LOWER CASE LETTER INDICATES SWITCH CONTROL
TR = TAMPER RESISTANT
HC = CONTROLLED RECEPTACLE, SPLIT YOKE, TOP OUTLET NOT CONTROLLED, BOTTOM OUTLET
CONTROLLED. MARK CONTROLLED YOKE IN ACCORDANCE WITH NEC 406.3.
FC = CONTROLLED DUPLEX RECEPTACLE/QUADRUPLEX RECEPTACLE, SEE DETAIL 1/E-502.
MARK CONTROLLED YOKE IN ACCORDANCE WITH NEC 406.3.
+xx = INDICATES MOUNTING HEIGHT MEASURED AFF. NEMA 5-20 RECEPTACLE UNLESS OTHERWISE NOTED.
TV = DEDICATED TV RECEPTACLE, INSTALLED BEHIND TV. COORDINATE MOUNTING HEIGHT
WITH TV INSTALLER AND CATV LOCATION.
HOMERUN, TYPICAL
"RC1" INDICATES POWER SOURCE.
"10" INDICATES CIRCUIT NUMBER.
RC1-10
CONDUIT UNDERGROUND, OR IN FLOOR SLAB
CONDUIT EXPOSED, SURFACE MOUNTED
GENERATOR QUICK DISCONNECT BOX "GEN"
BOTTOM OF EQUIPMENT TO NOT BE MORE THAN +27" AFF.
CONDUIT CONCELAED. LOW VOLTAGE CONTROL
CIRCUIT TO CONTROL PANEL, TYPICAL
STORM SHUTTER CONTROL PANEL, WALL MOUNTED AT +48" ABOVE FLOOR FINISH.
PROVIDE CLEAR AND LOCKABLE HOUSING. SEE DETAIL 2, EP119
UNDERGROUND DUCTBANK
SPECIAL PURPOSE RECEPTACLE. PROVIDED TO MATCH DEDICATED EQUIPMENT.
ROLLER SHADE CONTROL PANEL, WALL MOUNTED AT +48" ABOVE FLOOR FINISH.
PROVIDE CLEAR AND LOCKABLE HOUSING. SEE DETAIL 2, EP119
CONDUIT AND WIRE INDICATOR. SEE E-602
GROUND RING/ GROUND CONDUCTOR
Sheet List Table Sheet Number Sheet Title
E-001 LEGEND AND SHEET LIST
E-002 ELECTRICAL GENERAL NOTES
E-500 GROUNDING DETIALS
E-501 POWER DETAILS - EQP. LABELS, & CONTROL RCPT.
E-502 CNTRL RCPT. & LIGHTING CNTRL. WIRING DIAGRAM
E-601 POWER ONE-LINE DIAGRAM
E-602 CONDUIT AND WIRE SCHEDULE
E-603 GROUNDING DIAGRAM
E-604 PANEL SCHEDULE 480V - MDP, 4M1, L
E-605 PANEL SCHEDULE 208V - P1, P2, 2M1, FA
E-606 PANEL SCHEDULE 208V - RC1, RC2, RC3, RC4
E-607 PANEL SCHEDULE 208V - GTR, CTR, AV
EG100 LIGHTNING PROTECTION PLAN
EG500 LIGHTNING PROTECTION PLAN DETAILS PART 1
EG501 LIGHTNING PROTECTION PLAN DETAILS PART 2
EP111 FLOOR PLANS & ENLARGED DETAILS
EP112 FLOOR PLANS & ENLARGED DETAILS - AREA A
EP113 FLOOR PLANS & ENLARGED DETAILS - AREA B
EP114 FLOOR PLANS & ENLARGED DETAILS - CTR & GTR
EP115 FLOOR PLANS & ENLARGED DETAILS - ELECTRICAL ROOM
EP116 FLOOR PLANS & ENLARGED DETAILS - MECHANICAL YARD
EP117 FLOOR PLANS & ENLARGED DETAILS - KITCHEN
EP118 FLOOR PLANS & ENLARGED DETAILS - CLERESTORY
EP119 FLOOR PLANS & ENLARGED DETAILS - WINDOW CONTROLS
ES110 POWER SITE PLAN - OVERALL SITE PLAN
ES111 POWER SITE PLAN - OVERALL SITE PLAN CONTINUED
ES112 POWER SITE PLAN - GROUNDING SITE PLAN
ES113 POWER SITE PLAN - GROUNDING SITE PLAN CONTINUED
ES510 POWER SITE PLANS - DETAILS - DUCT BANK
ES511 POWER SITE PLANS - DETAILS - MAINTENANCE HOLE
ES512 POWER SITE PLANS - DETAILS - PATCH AND BREAK
ES513 POWER SITE PLANS - DETAILS-RANSFORMER ENCLOSURE
LE
G
E N
D A
N D
S H
E E
T
LI
S T
E-001
JKS
M O
TO
R
D
IS
C O
N N
EC
T
C
LA
R
IF
IC
AT
IO
N
S
N O
V
PANEL SCHEDULE 208Y/120V, DISTRIBUTION
SCALE: NONE 1
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
OF
EPROJECT NO.:
DM
BRANCH MANAGER
CHIEF ENG
FIRE PROTECTION
NA
VF
AC
P
AC
IF
IC
NA
VF
AC
P
AC
IF
IC
MA
KA
LA
PA
, H
AW
AI
I
US
N
AV
SU
PP
AC
T M
CB
G
UA
M
FI
NE
G
AY
AN
, G
UA
M
FY
M
CO
N P-
RE
CR
EA
TI
O N
CE
NT
ER
08/22/2023
MPU
BMC
JCC
1737348
APPROVED BY RANDALL TORIGOE,
MILCON PLANNER, DPP-H
VIA EMAIL
1. CONNECT THE SPD ON THE BUSSING CLOSEST TO THE INCOMING FEEDER.
ADDITIONALLY, POSITION THE SPD DIRECTLY ADJACENT TO THE CIRCUIT
BREAKER WHICH FEEDS IT, SO THAT THE WIRING FROM THE CIRCUIT
BREAKER DOES NOT CONTAIN ANY BENDS IS AS SHORT AS POSSIBLE.
2. IN ADDITION TO THE PANELBOARD NAMEPLATE, PROVIDE A LABEL
INSCRIBED WITH : " Fire Protection/Life Safety Equipment." LABEL MUST BE
RED LAMINATED PLASTIC WITH WHITE CENTER CORE AND PAINT THE
PANELBOARD RED.
X. 3. PROVIDE LOCKABLE CIRCUIT
BEAKER CLASP ATTACHMENT
4. PROVIDE GFCI BREAKER
P A
N E
L S
C H
E D
U
LE
V
G
TR
, C
TR
, A V
E-607
JKS
R
EV
IS
ED
P
AN
EL
A
V C
IR
C
U
IT
,3
,5 D
ES
C
R
IP
TI
O
N S
N
O V
U P
3 3
U P
3 3
U P
3 3
U P
3 3
DOAS-1
GFCI
HC
RC4-27
HC
RC4-19
W
RC3-26
HC
RC4-19
WP, GFCI
RC2-32
WP, GFCI
RC2-21
WP, GFCI
RC3-2
HC
RC3-12
HC
RC3-12
HC
RC4-14
W
RC3-24
WP, GFCI
RC3-2
W, +18"
RC2-31
W, +18"
RC2-31
W, +18"
RC2-33
W, +18"
RC2-33
W, +18"
RC2-35
RC2-27 RC2-29 RC2-29W, +18"
RC2-27
RC2-23
RC2-23
RC2-21
RC2-23RC2-23
RC2-21 RC2-21
RC2-21
V C3-19
RC3-4
RC3-9
RC3-2
TV
RC3-15
TV
RC3-4
TV
RC3-2
TV,GFCI
RC3-2
TV
RC3-2
RC3-9RC3-9 RC3-11RC3-13
RC3-21
RC3-21 RC3-21
RC3-8
RC3-6
RC3-19
C3-23
WP, GFCI
RC3-2
2M1-41
RC4-21
RC4-27
RC4-13
RC4-20
RC3-2
W,WP
RC3-2
RC3-5
IG
AV-2
2M1-39
RC2-30
GFCI,
RC2-30
RC2-32
RC2-32
4M1-2,4,6
2M1-17,19
2M1-37
2M1-13,15
2M1-13,15
2M1-13,15
0 RC3-10
RC4-21
RC4-21
RC4-21
RC4-21
RC4-25
RC4-23
RC3-4
RC3-4
RC4-1RC4-3
RC4-4
RC4-5
RC4-6RC4-8
RC4-9
RC4-10
RC4-11RC4-12
RC4-7
RC4-15
RC4-16
RC4-17
RC4-17
RC4-17
RC4-17
RC4-22
RC4-18
RC4-18
TV
RC4-26
RC4-24
RC4-24
RC4-18RC4-18
RC4-24
RC4-26
5 6 8
A
D
C
B.5
B.4
B
RC2-25
C
RC2-37
RC4-24 RC4-24
RC4-27
2M1-9,11
2M1-29,31
2M1-29,31 2M1-21,23
CUSTOMER
SERVICE
AREA
ABV
2M1-16
ABV
2M1-18
ABV
2M1-20
ABV
2M1-24
ABV
2M1-26
ABV
2M1-32
ABV
2M1-34
ABV
2M1-22
2M1-36
2M1-35
2M1-35
2M1-35
2M1-35
IG
AV-4
2M1-41
C3-23
TV
RC3-2
RC4-2
7 2M1-40
2M1-40
ABV
2M1-16
ABV
2M1-18
ABV
2M1-20
ABV
2M1-26
ABV
2M1-24
W
RC3-20
W
RC3-18
+76"
RC2-38
+76"
RC2-34
RC2-30
S,GFCI
W
RC2-36
2M1-38
2M1-17,19W
RC2-40
W
RC2-42
W
RC2-44
W
RC2-46
W 2M1-39
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
OF
EPROJECT NO.:
DM
BRANCH MANAGER
CHIEF ENG
FIRE PROTECTION
NA
VF
AC
P
AC
IF
IC
NA
VF
AC
P
AC
IF
IC
MA
KA
LA
PA
, H
AW
AI
I
US
N
AV
SU
PP
AC
T M
CB
G
UA
M
FI
NE
G
AY
AN
, G
UA
M
FY
M
CO
N P-
RE
CR
EA
TI
O N
CE
NT
ER
08/22/2023
MPU
BMC
JCC
1737348
APPROVED BY RANDALL TORIGOE,
MILCON PLANNER, DPP-H
VIA EMAIL
M
AT
CH
L
IN
E
TO
E
P1
POWER - ENLARGED FLOOR PLAN - AREA B
SCALE: 3/16"=1'-0" 1EP111
EP113
X
EP112
EP116
EP114
1. PROVIDE CLEAR AND LOCKABLE HOUSING FOR STORM SHUTTER AND
ROLLER SHADE CONTROL PANEL. CONTROL PANEL TO BE INSTALLED +36"
AFF.
A. ALL FEEDER OR BRANCH CIRCUIT CONDUITS ARE NOT SHOWN. PROVIDE
CIRCUITS AS NEEDED.
B. FOR JUNCTION BOXES AND RECEPTACLES THAT ARE DEDICATED
FOR EQUIPMENT, COORDINATE EXACT LOCATION WITH EQUIPMENT
INSTALLER. REFER TO PANEL SCHEDULE FOR JUNCTION BOXES AND
RECEPTACLES THAT ARE DEDICATED.
D. FOR EQUIPMENT WITH ACCESS PANELS, INSTALL DISCONNECT SO
THAT IT IS ACCESSIBLE THROUGH ACCESS PANEL OPENING.
FL
O
O R
P
LA
N S
E
N
LA
R G
E D
D E
TA
IL
S
A R
E A
B
EP113
JKS
R
EV
IS
ED
A V
G R
O U
N D
IN
G
R
EQ
U
IR
EM
EN
TS
N
O V
GTR-10
GTR-9
GTR-5
GTR-1
WP, GFCI
2M1-42
WP, GFCI
2M1-42
GTR-3
GTR-8
GTR-12
GTR-11
GTR-2
2M1-1,3
NEMA 4X
60 AMP,10 HP
2M1-5,7
NEMA 4X
30 AMP,3 HP
ACCU-3ACCU-2
GTR-17
GTR-19
GTR-21
GTR-21
GTR-21
GTR-21
GTR-21
GTR-21
GTR-7
GT
R-
GT
R-
GT
R-
GT
R-
2M1-42
2M1-42
CT
R-
CT
R-
CT
R-
CT
R-
IG AV
-1
IG AV
-5
IG
AV-3
IG AV
-7
CTR-8 CTR-6 CTR-9
CTR-9
CTR-9
CTR-9
CTR-9
2M1-42
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
OF
EPROJECT NO.:
DM
BRANCH MANAGER
CHIEF ENG
FIRE PROTECTION
NA
VF
AC
P
AC
IF
IC
NA
VF
AC
P
AC
IF
IC
MA
KA
LA
PA
, H
AW
AI
I
US
N
AV
SU
PP
AC
T M
CB
G
UA
M
FI
NE
G
AY
AN
, G
UA
M
FY
M
CO
N P-
RE
CR
EA
TI
O N
CE
NT
ER
08/22/2023
MPU
BMC
JCC
1737348
APPROVED BY RANDALL TORIGOE,
MILCON PLANNER, DPP-H
VIA EMAIL
POWER - ENLARGED PLAN - GTR
SCALE: 1/2"=1'-0" 1EP111
POWER - ENLARGED PLAN - CTR
SCALE: 1/2"=1'-0" 2EP111
B. PROVIDE L5-20R RECEPTACLES FOR ALL SPECIAL RECEPTACLES
SHOWN. MOUNT RECEPTACLE TO UNDERSIDE OF LADDER RACK (FACE
DOWN).
EP113EP112
1. NA
FL
O
O R
P
LA
N S
E
N
LA
R G
E D
D E
TA
IL
S
C
TR
G
TR
EP114
JKS
R
EV
IS
ED
A V
G R
O U
N D
IN
G
R
EQ
U
IR
EM
EN
TS
N
O V
| AMD7 |
| Pg2 |
| P406 Amendment 01-Drawings signed |
| P406 Amendment 0003-Drawings-signed |
| P406 Amendment 0004-Drawings-signed |
File details come from the government source that posted it. Updated .