23R1316_AMD4.pdf
PDF 4 MB Posted
- Attached to
- FY22 MCAF PAF180700 SQUADRON OPERATIONS FACILITY, ROYAL AUSTRALIAN AIR FORCE BASE TINDAL, AUSTRALIA
- Solicitation number
- N6274223R1316
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 23R1316 Note 6.pdf | ||
| 23R1316_AMD6.pdf | ||
| 23R1316_AMD5.pdf | ||
| 23R1316 Note 5.pdf | ||
| 23R1316 Note 4.pdf | ||
| 23R1316 AMD3.pdf | ||
| 23R1316_AMD2.pdf | ||
| 23R1316 Note 3.pdf | ||
| P700 SV Sign-in.pdf | ||
| 23R1316_AMD1.pdf | ||
| 23R1316 Note 2.pdf | ||
| 23R1316 Note 1.pdf | ||
| 1665827-P700 Specification_Signed_REV_MAY2023.pdf | ||
| 1665827-P-700 Drawings - 2 of 2.pdf | ||
| 1665827-P-700 Drawings - 1 of 2.pdf | ||
| 23R1316-RFP.pdf |
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RFP No. N6274223R1316 Amendment No. 0004
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
The following items are applicable to this modification:
SPECIFICATIONS
SECTION 27 10 00 – BUILDING TELECOMMUNICATIONS CABLING SYSTEM
Remove Replace with Pages 1-17 Pages 1-17 Amendment No. 0004
DRAWINGS
The following drawings supersede previously issued drawings bearing the same number and title:
DRAWING
NUMBER
NAVFAC
DRAWING
NUMBER
DRAWING TITLE
C-102 17270504 SITE LAYOUT PLAN
C-121 17270506 STORMWATER AND UTILITIES PLAN
A-101 17270520 FLOOR PLAN
A-102 17270521 REFLECTED CEILING PLAN
FY22 MCAF PROJECT PAF180700 SQUADRON OPERATIONS FACILITY 1665827
RAAF, TINDAL
Section 27 10 00 Page 1
AMENDMENT 0004
SECTION 27 10 00
BUILDING TELECOMMUNICATIONS CABLING SYSTEM
08/11
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM D709 (2017) Standard Specification for Laminated Thermosetting Materials
ELECTRONIC COMPONENTS INDUSTRY ASSOCIATION (ECIA)
ECIA EIA/ECA 310-E (2005) Cabinets, Racks, Panels, and Associated Equipment
INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE)
IEEE 100 (2000; Archived) The Authoritative Dictionary of IEEE Standards Terms
INSULATED CABLE ENGINEERS ASSOCIATION (ICEA)
ICEA S-83-596 (2016) Indoor Optical Fiber Cables
ICEA S-90-661 (2012) Category 3, 5, & 5e Individually Unshielded Twisted Pair Indoor Cables for Use in General Purpose and LAN Communications Wiring Systems Technical Requirements
AUSTRALIAN CYBER SECURITY CENTRE (ACSC)
ISM Information Security Manual
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION (ISO)
ISO 540 (2008) Hard Coal and Coke - Determination of Ash Fusibility
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)
ANSI/NEMA WC 66 (2013) Performance Standard for Category 6 and Category 7 100 Ohm Shielded and Unshielded Twisted Pairs
TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA)
TIA-455-21 (1988a; R 2012) FOTP-21 - Mating Durability of Fiber Optic Interconnecting Devices
Section 27 10 00 Page 2
AMENDMENT 0004
TIA-526-7 (2015a) OFSTP-7 Measurement of Optical Power Loss of Installed Single-Mode Fiber Cable Plant
TIA-568-C.0 (2009; Add 1 2010; Add 2 2012) Generic Telecommunications Cabling for Customer Premises
TIA-568-C.1 (2009; Add 2 2011; Add 1 2012) Commercial Building Telecommunications Cabling Standard
TIA-568-C.2 (2009; Errata 2010; Add 2 2014; Add 1 2016) Balanced Twisted-Pair Telecommunications Cabling and Components Standards
TIA-568-C.3 (2008; Add 1 2011) Optical Fiber Cabling Components Standard
TIA-569 (2015d) Commercial Building Standard for Telecommunications Pathways and Spaces
TIA-606 (2017c) Administration Standard for the Telecommunications Infrastructure
TIA-607 (2015c; Addendum 1 2017) Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises
TIA-1152 (2009) Requirements for Field Test Instruments and Measurements for Balanced Twisted-Pair Cabling
TIA/EIA-604-10 (2002a) FOCIS 10 Fiber Optic Connector Intermateability Standard - Type LC
U.S. FEDERAL COMMUNICATIONS COMMISSION (FCC)
FCC Part 68 Connection of Terminal Equipment to the Telephone Network (47 CFR 68)
UNDERWRITERS LABORATORIES (UL)
UL 50 (2015) UL Standard for Safety Enclosures for Electrical Equipment, Non-Environmental Considerations
UL 969 (2017; Reprint Mar 2018) UL Standard for Safety Marking and Labeling Systems
1.2 RELATED REQUIREMENTS
Section 26 20 00 INTERIOR DISTRIBUTION SYSTEM applies to this section with additions and modifications specified herein.
1.3 DEFINITIONS
Section 27 10 00 Page 3
AMENDMENT 0004
Unless otherwise specified or indicated, electrical and electronics terms used in this specification shall be as defined in TIA-568-C.1, TIA-568-C.2, TIA-568-C.3, TIA-569, TIA-606 and IEEE 100 and herein.
1.3.1 Campus Distributor (CD)
A distributor from which the campus backbone cabling emanates.
1.3.2 Building Distributor (BD)
A distributor in which the building backbone cables terminate and at which connections to the campus backbone cables may be made.
1.3.3 Floor Distributor (FD)
A distributor used to connect horizontal cable and cabling subsystems or equipment.
1.3.4 Telecommunications Room (TR)
An enclosed space for housing telecommunications equipment, cable, terminations, and cross-connects. The room is the recognized cross-connect between the backbone cable and the horizontal cabling.
1.3.5 Entrance Facility (EF) (Telecommunications)
An entrance to the building for both private and public network service cables (including wireless) including the entrance point at the building wall and continuing to the equipment room.
1.3.6 Equipment Room (ER) (Telecommunications)
An environmentally controlled centralized space for telecommunications equipment that serves the occupants of a building. Equipment housed therein is considered distinct from a telecommunications room because of the nature of its complexity.
1.3.7 Open Cable
Cabling that is not run in a raceway. This refers to cabling that is "open" to the space in which the cable has been installed and is therefore exposed to the environmental conditions associated with that space.
1.3.8 Open Office
A floor space division provided by furniture, moveable partitions, or other means instead of by building walls.
1.3.9 Pathway
A physical infrastructure utilized for the placement and routing of telecommunications cable.
1.4 SYSTEM DESCRIPTION
The building telecommunications cabling and pathway system shall include permanently installed backbone and horizontal cabling, horizontal and
Section 27 10 00 Page 4
AMENDMENT 0004
backbone pathways, service entrance facilities, work area pathways, telecommunications outlet assemblies, conduit, raceway, and hardware for splicing, terminating, and interconnecting cabling necessary to transport telephone and data (including LAN) between equipment items in a building.
The horizontal system shall be wired in a star topology from the telecommunications work area to the floor distributor at the center or hub of the star. The backbone cabling and pathway system includes interbuilding interconnecting cabling, pathway, and terminal hardware. The backbone system shall be wired in a star topology with the campus distributor at the center or hub of the star. Provide telecommunications pathway systems referenced herein as specified in Section 26 20 00 INTERIOR DISTRIBUTION SYSTEM. The telecommunications contractor must coordinate with CIOG concerning access to and configuration of telecommunications spaces.
1.5 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for Contractor Quality Control approval. Submit the following in accordance with Section 01 33 00 SUBMITTAL
PROCEDURES:
SD-02 Shop Drawings
Telecommunications drawings; G
Telecommunications Space Drawings; G
In addition to Section 01 33 00 SUBMITTAL PROCEDURES, provide shop drawings in accordance with paragraph SHOP DRAWINGS.
SD-03 Product Data
Telecommunications cabling (backbone and horizontal); G
Patch panels; G
Telecommunications outlet/connector assemblies; G
Equipment support frame; G
Connector blocks; G
Submittals shall include the manufacturer's name, trade name, place of manufacture, and catalog model or number. Include performance and characteristic curves. Submittals shall also include applicable federal, military, industry, and technical society publication references. Should manufacturer's data require supplemental information for clarification, the supplemental information shall be submitted as specified in paragraph REGULATORY REQUIREMENTS and as required in Section 01 33 00 SUBMITTAL
PROCEDURES.
SD-06 Test Reports
Telecommunications cabling testing; G
SD-07 Certificates
Section 27 10 00 Page 5
AMENDMENT 0004
Telecommunications Contractor Qualifications; G
Key Personnel Qualifications; G
Manufacturer Qualifications; G
Test plan; G
SD-09 Manufacturer's Field Reports
Factory reel tests; G
SD-10 Operation and Maintenance Data
Telecommunications cabling and pathway system Data Package 5; G
SD-11 Closeout Submittals
Record Documentation; G
1.6 QUALITY ASSURANCE
1.6.1 Shop Drawings
In exception to Section 01 33 00 SUBMITTAL PROCEDURES, submitted plan drawings shall be a minimum of 279 by 432 mm in size using a minimum scale of one mm per 100 mm. Include wiring diagrams and installation details of equipment indicating proposed location, layout and arrangement, control panels, accessories, piping, ductwork, and other items that must be shown to ensure a coordinated installation. Wiring diagrams shall identify circuit terminals and indicate the internal wiring for each item of equipment and the interconnection between each item of equipment. Drawings shall indicate adequate clearance for operation, maintenance, and replacement of operating equipment devices. Submittals shall include the nameplate data, size, and capacity. Submittals shall also include applicable federal, military, industry, and technical society publication references.
1.6.1.1 Telecommunications Drawings
Provide drawings in accordance with TIA-606. The identifier for each termination and cable shall appear on the drawings. Drawings shall depict final telecommunications installed wiring system infrastructure in accordance with TIA-606. The drawings should provide details required to prove that the distribution system shall properly support connectivity from the EF telecommunications and ER telecommunications, CD's and BD's to the telecommunications work area outlets. The following drawings shall be provided as a minimum:
a. T1 - Layout of complete building - Building Area/Serving Zone Boundaries, Backbone Systems, and Horizontal Pathways. Layout of complete building. The drawing indicates location of building areas, serving zones, vertical backbone diagrams, telecommunications rooms, access points, pathways, earthing system, and other systems that need to be viewed from the complete building perspective.
Section 27 10 00 Page 6
AMENDMENT 0004
b. T2 - Serving Zones/Building Area Drawings - Drop Locations and Cable Identification (ID’s). Shows a building area or serving zone. These drawings show drop locations, telecommunications rooms, access points and detail call outs for equipment rooms and other congested areas.
c. T4 - Typical Detail Drawings - Faceplate Labeling, Firestopping, Safety. Detailed drawings of symbols and typicals such as faceplate labeling, faceplate types, faceplate population installation procedures, detail racking, and raceways.
1.6.1.2 Telecommunications Space Drawings
Provide T3 drawings in accordance with TIA-606 that include telecommunications rooms plan views, pathway layout (cable tray, racks, ladder-racks, etc.), mechanical/electrical layout, and rack elevations.
Drawings shall show layout of applicable equipment including incoming cable stub or connector blocks, building protector assembly, outgoing cable connector blocks, patch panels and equipment spaces and cabinet/racks.
Drawings shall include a complete list of equipment and material, equipment rack details, proposed layout and anchorage of equipment and appurtenances, and equipment relationship to other parts of the work including clearance for maintenance and operation. Drawings may also be an enlargement of a congested area of T1 or T2 drawings.
1.6.2 Telecommunications Qualifications
Work under this section shall be performed by and the equipment shall be provided by the approved telecommunications contractor and key personnel.
Qualifications shall be provided for: the telecommunications system contractor, the telecommunications system installer, and the supervisor (if different from the installer). A minimum of 30 days prior to installation, submit documentation of the experience of the telecommunications contractor and of the key personnel.
1.6.2.1 Telecommunications Contractor
The telecommunications contractor shall be a firm which is regularly and professionally engaged in the business of the applications, installation, and testing of the specified telecommunications systems and equipment. The telecommunications contractor shall demonstrate experience in providing successful telecommunications systems within the past 3 years of similar scope and size. Submit documentation for a minimum of three and a maximum of five successful telecommunication system installations for the telecommunications contractor.
1.6.2.2 Key Personnel
Provide key personnel who are regularly and professionally engaged in the business of the application, installation and testing of the specified telecommunications systems and equipment. There may be one key person or more key persons proposed for this solicitation depending upon how many of the key roles each has successfully provided. Each of the key personnel shall demonstrate experience in providing successful telecommunications systems within the past 3 years.
Supervisors and installers assigned to the installation of this system or any of its components shall have a minimum of 3 years experience in the
Section 27 10 00 Page 7
AMENDMENT 0004
installation of the specified copper and fibre optic cable and components.
They shall have factory or factory approved certification from each equipment manufacturer indicating that they are qualified to install and test the provided products. Submit documentation for a minimum of three and a maximum of five successful telecommunication system installations for each of the key personnel. Documentation for each key person shall include at least two successful system installations provided that are equivalent in system size and in construction complexity to the telecommunications system proposed for this solicitation. Include specific experience in installing and testing telecommunications systems and provide the names and locations of at least two project installations successfully completed using optical fibre and copper telecommunications cabling systems. All of the existing telecommunications system installations offered by the key persons as successful experience shall have been in successful full-time service for at least 18 months prior to the issuance date for this solicitation. Provide the name and role of the key person, the title, location, and completed installation date of the referenced project, the referenced project owner point of contact information including name, organization, title, and telephone number, and generally, the referenced project description including system size and construction complexity.
Indicate that all key persons are currently employed by the telecommunications contractor, or have a commitment to the telecommunications contractor to work on this project. All key persons shall be employed by the telecommunications contractor at the date of issuance of this solicitation, or if not, have a commitment to the telecommunications contractor to work on this project by the date that the bid was due to the Contracting Officer.
Note that only the key personnel approved by the Contracting Officer in the successful proposal shall do work on this solicitation's telecommunications system. Key personnel shall function in the same roles in this contract, as they functioned in the offered successful experience. Any substitutions for the telecommunications contractor's key personnel requires approval from The Contracting Officer.
1.6.2.3 Minimum Manufacturer Qualifications
Cabling, equipment and hardware manufacturers shall have a minimum of 3 years experience in the manufacturing, assembly, and factory testing of components which comply with TIA-568-C.1, TIA-568-C.2 and TIA-568-C.3.
1.6.3 Test Plan
Provide a complete and detailed test plan for the telecommunications cabling system including a complete list of test equipment for the components and accessories for each cable type specified, 60 days prior to the proposed test date. Include procedures for certification, validation, and testing.
1.6.4 Regulatory Requirements
In each of the publications referred to herein, consider the advisory provisions to be mandatory, as though the word, "shall" had been substituted for "should" wherever it appears. Interpret references in these publications to the "authority having jurisdiction," or words of similar meaning, to mean the Contracting Officer. Equipment, materials, installation, and workmanship shall be in accordance with the mandatory and
Section 27 10 00 Page 8
AMENDMENT 0004
advisory provisions of applicable Australian Standards unless more stringent requirements are specified or indicated.
1.6.5 Standard Products
Provide materials and equipment that are products of manufacturers regularly engaged in the production of such products which are of equal material, design and workmanship. Products shall have been in satisfactory commercial or industrial use for 2 years prior to bid opening. The 2-year period shall include applications of equipment and materials under similar circumstances and of similar size. The product shall have been on sale on the commercial market through advertisements, manufacturers' catalogs, or brochures during the 2-year period. Where two or more items of the same class of equipment are required, these items shall be products of a single manufacturer;
however, the component parts of the item need not be the products of the same manufacturer unless stated in this section.
1.6.5.1 Alternative Qualifications
Products having less than a 2-year field service record will be acceptable if a certified record of satisfactory field operation for not less than 6000 hours, exclusive of the manufacturers' factory or laboratory tests, is furnished.
1.6.5.2 Material and Equipment Manufacturing Date
Products manufactured more than 1 year prior to date of delivery to site shall not be used, unless specified otherwise.
1.7 DELIVERY AND STORAGE
Provide protection from weather, moisture, extreme heat and cold, dirt, dust, and other contaminants for telecommunications cabling and equipment placed in storage.
1.8 ENVIRONMENTAL REQUIREMENTS
Connecting hardware shall be rated for operation under ambient conditions of 0 to 60 degrees C and in the range of 0 to 95 percent relative humidity, noncondensing.
1.9 WARRANTY
The equipment items shall be supported by service organizations which are reasonably convenient to the equipment installation in order to render satisfactory service to the equipment on a regular and emergency basis during the warranty period of the contract.
1.10 MAINTENANCE
1.10.1 Operation and Maintenance Manuals
Commercial off the shelf manuals shall be furnished for operation, installation, configuration, and maintenance of products provided as a part of the telecommunications cabling and pathway system, Data Package 5.
Submit operations and maintenance data in accordance with Section 01 78 23 OPERATION AND MAINTENANCE DATA and as specified herein not later than 2
Section 27 10 00 Page 9
AMENDMENT 0004
months prior to the date of beneficial occupancy. In addition to requirements of Data Package 5, include the requirements of paragraphs TELECOMMUNICATIONS DRAWINGS, TELECOMMUNICATIONS SPACE DRAWINGS, and RECORD DOCUMENTATION. Ensure that these drawings and documents depict the as-built configuration.
1.10.2 Record Documentation
Provide T5 drawings including documentation on cables and termination hardware in accordance with TIA-606. T5 drawings shall include schedules to show information for cut-overs and cable plant management, patch panel layouts and cover plate assignments, cross-connect information and connecting terminal layout as a minimum. T5 drawings shall be provided in hard copy format. Provide the following T5 drawing documentation as a minimum:
a. Cables - A record of installed cable shall be provided in accordance with TIA-606. The cable records shall include only the required data fields in accordance with TIA-606. Include manufacture date of cable with submittal.
b. Termination Hardware - A record of installed patch panels, cross-connect points, distribution frames, terminating block arrangements and type, and outlets shall be provided in accordance with TIA-606.
Documentation shall include the required data fields only in accordance with TIA-606.
PART 2 PRODUCTS
2.1 COMPONENTS
Components shall be UL or third party certified. Where equipment or materials are specified to conform to industry and technical society reference standards of the organizations, submit proof of such compliance.
The label or listing by the specified organization will be acceptable evidence of compliance. In lieu of the label or listing, submit a certificate from an independent testing organization, competent to perform testing, and approved by the Contracting Officer. The certificate shall state that the item has been tested in accordance with the specified organization's test methods and that the item complies with the specified organization's reference standard. Provide a complete system of telecommunications cabling and pathway components using star topology.
Provide support structures and pathways, complete with outlets, cables, connecting hardware and telecommunications cabinets/racks. Cabling and interconnecting hardware and components for telecommunications systems shall be testing laboratory certified, and shall conform to the requirements specified herein.
2.2 TELECOMMUNICATIONS PATHWAY
Provide telecommunications pathways in accordance with TIA-569 and as specified in Section 26 20 00 INTERIOR DISTRIBUTION SYSTEM.
2.3 TELECOMMUNICATIONS CABLING
Cabling shall be UL listed for the application and shall comply with TIA- 568-C.0, TIA-568-C.1, TIA-568-C.2, and TIA-568-C.3. Provide a labeling
Section 27 10 00 Page 10
AMENDMENT 0004
system for cabling as required by TIA-606 and UL 969. Ship cable on reels or in boxes bearing manufacture date for unshielded twisted pair (UTP) in accordance with ICEA S-90-661 and optical fibre cables in accordance with ICEA S-83-596 for all cable used on this project. Cabling manufactured more than 12 months prior to date of installation shall not be used.
2.3.1 Backbone Cabling
2.3.1.1 Backbone Optical Fibre
Provide in accordance with ICEA S-83-596 and TIA-568-C.3. Cable shall be imprinted with fibre count, fibre type and aggregate length at regular intervals not to exceed 1 meter.
Provide the number of strands indicated, (but not less than 12 strands between the main telecommunication room and each of the other telecommunication rooms), of single-mode(OS1), tight buffered fibre optic cable.
2.3.2 Horizontal Cabling
Provide horizontal cable in compliance with applicable Australian Standards and performance characteristics in accordance with TIA-568-C.1.
2.3.2.1 Horizontal Copper
Provide horizontal copper cable, UTP, 100 ohm in accordance with TIA-568- C.2, ANSI/NEMA WC 66, ICEA S-90-661. Provide four each individually twisted pair, minimum size 0.25 mm2 conductors, Category 6e, with a thermoplastic jacket. Cable shall be imprinted with manufacturers name or identifier, flammability rating, size of conductor, transmission performance rating (category designation) and length marking at regular intervals in accordance with ICEA S-90-661. Provide plenum (CMP), riser (CMR), or general purpose (CM or CMG) communications rated cabling suitable for the intended use.
Substitution of a higher rated cable shall be permitted. Cables installed in conduit within and under slabs shall be suitable for use in wet locations.
All copper cables shall have an outer jacket colour of in accordance with Security Control 0825 and 0826 the ISM; all foreignnon-Australian systems (including NIPRNET, SIPRNET, and JWICS) shall be green.
2.3.3 Work Area Cabling
2.3.3.1 Work Area Copper
Provide work area copper cable in accordance with TIA-568-C.2, with a thermoplastic jacket.
All copper cables shall have an outer jacket colour of in accordance with Security Control 0825 and 0826 the ISM; all foreignnon-Australian systems (including NIPRNET, SIPRNET, and JWICS) shall be green.
2.4 TELECOMMUNICATIONS SPACES
Provide connecting hardware and termination equipment in the telecommunications entrance facility to facilitate installation as shown on design drawings for terminating and cross-connecting permanent cabling.
Section 27 10 00 Page 11
AMENDMENT 0004
Provide telecommunications interconnecting hardware color coding in accordance with TIA-606.
2.4.1 Equipment Support Frame
Provide in accordance with ECIA EIA/ECA 310-E and UL 50.
a. Racks, floor mounted modular type, steel construction, treated to resist corrosion. Provide rack with vertical and horizontal cable management channels, top and bottom cable troughs, earthing lug and a surge protected power strip with 6 GPOs.
2.4.2 Connector Blocks
Provide insulation displacement connector (IDC) Type 110 for Category 6 systems. Provide blocks for the number of horizontal and backbone cables terminated on the block plus 25 percent spare.
2.4.3 Cable Guides
Provide cable guides specifically manufactured for the purpose of routing cables, wires and patch cords horizontally and vertically on equipment racks. Cable guides of ring or bracket type devices mounted on rack for horizontal cable management and individually mounted for vertical cable management. Mount cable guides with screws, and/or nuts and lockwashers.
2.4.4 Patch Panels
Provide ports for the number of horizontal and backbone cables terminated on the panel plus 25 percent spare. Provide pre-connectorized copper patch cords for patch panels. Provide patch cords, as complete assemblies, with matching connectors as specified. Patch cords shall meet minimum performance requirements specified in TIA-568-C.1 and TIA-568-C.2 for cables, cable length and hardware specified.
2.4.4.1 Modular to 110 Block Patch Panel
Provide in accordance with TIA-568-C.1 and TIA-568-C.2. Panels shall be third party verified and shall comply with EIA/TIA Category 6e requirements.
Panel shall be constructed of 2.2 mm minimum aluminum and shall be rack mounted and compatible with an ECIA EIA/ECA 310-E equipment rack. Panel shall provide 48 non-keyed, 8-pin modular ports, wired to T568B. Patch panels shall terminate the building cabling on Type 110 IDCs and shall utilize a printed circuit board interface. The rear of each panel shall have incoming cable strain-relief and routing guides. Panels shall have each port factory numbered and be equipped with laminated plastic nameplates above each port.
2.4.4.2 Fibre Optic Patch Panel
Provide panel for maintenance and cross-connecting of optical fibre cables.
Panel shall be constructed of steel and shall be rack mounted and compatible with a ECIA EIA/ECA 310-E equipment rack. Each panel shall provide 12 single-mode adapters as duplex LC in accordance with TIA/EIA-604-10 with zirconia ceramic alignment sleeves. Provide dust cover for unused adapters.
The rear of each panel shall have a cable management tray with removable cover, incoming cable strain-relief and routing guides. Panels shall have
Section 27 10 00 Page 12
AMENDMENT 0004
each adapter factory numbered and be equipped with laminated plastic nameplates above each adapter.
2.5 TELECOMMUNICATIONS OUTLET/CONNECTOR ASSEMBLIES
2.5.1 Outlet/Connector Copper
Outlet/connectors shall comply with FCC Part 68, TIA-568-C.1, and TIA-568- C.2. UTP outlet/connectors shall be non-keyed, 8-pin modular, constructed of high impact rated thermoplastic housing and shall be third party verified and shall comply with TIA-568-C.2 Category 6e requirements.
Outlet/connectors provided for UTP cabling shall meet or exceed the requirements for the cable provided. Outlet/connectors shall be terminated using a Type 110 IDC PC board connector, color-coded for both T568A and T568B wiring. Each outlet/connector shall be wired T568B. UTP outlet/connectors shall comply with TIA-568-C.2 for 200 mating cycles.
2.5.2 Optical Fibre Connectors
Provide in accordance with TIA-455-21. Optical fibre connectors shall be duplex LC in accordance with TIA/EIA-604-10 with zirconia ceramic alignment sleeves, epoxyless crimp style compatible with 8/125 single-mode fibre. The connectors shall provide a maximum attenuation of 0.3 dB at 1550 nm with less than a 0.2 dB change after 500 mating cycles.
2.5.3 Cover Plates
Telecommunications cover plates shall comply with and TIA-568-C.1, TIA-568- C.2, and TIA-568-C.3; constructed of high impact thermoplastic material white in color. Provide labeling in accordance with the paragraph LABELING in this section.
2.6 EARTHING AND BONDING PRODUCTS
Provide in accordance with TIA-607. Components shall be identified as required by TIA-606. Provide rod electrodes, bonding conductors, and earthing busbars as specified in Section 26 20 00 INTERIOR DISTRIBUTION
SYSTEM.
2.7 FIRESTOPPING MATERIAL
Provide firestopping around wall and ceiling penetrations. The material used for the fire-stopping of service penetrations must be concrete, high-temperature mineral fibre, high-temperature ceramic fibre or other material that does not flow at a temperature below 1120 degrees C when tested in accordance with ISO 540, and must have demonstrated that it does not impair the fire resisting performance of the building element in which it is installed.
2.8 MANUFACTURER'S NAMEPLATE
Each item of equipment shall have a nameplate bearing the manufacturer's name, address, model number, and serial number securely affixed in a conspicuous place; the nameplate of the distributing agent will not be acceptable.
Section 27 10 00 Page 13
AMENDMENT 0004
2.9 FIELD FABRICATED NAMEPLATES
ASTM D709. Provide laminated plastic nameplates for each equipment enclosure, relay, switch, and device; as specified or as indicated on the drawings. Each nameplate inscription shall identify the function and, when applicable, the position. Nameplates shall be melamine plastic, 3 mm thick, white with black center core. Surface shall be matte finish.
Corners shall be square. Accurately align lettering and engrave into the core. Minimum size of nameplates shall be 25 by 65 mm . Lettering shall be a minimum of 6.35 mm high normal block style.
2.10 TESTS, INSPECTIONS, AND VERIFICATIONS
2.10.1 Factory Reel Tests
Provide documentation of the testing and verification actions taken by manufacturer to confirm compliance with TIA-568-C.1, TIA-568-C.2, TIA-568- C.3, and TIA-526-7 for single mode optical fibre cables.
PART 3 EXECUTION
3.1 INSTALLATION
Install telecommunications cabling and pathway systems, including the horizontal and backbone cable, pathway systems, telecommunications outlet/connector assemblies, and associated hardware in accordance with TIA- 568-C.1, TIA-568-C.2, TIA-568-C.3, and TIA-569 as applicable. Provide cabling in a star topology network. Pathways and outlet boxes shall be installed as specified in Section 26 20 00 INTERIOR DISTRIBUTION SYSTEM.
Install telecommunications cabling with copper media in accordance with the following criteria to avoid potential electromagnetic interference between power and telecommunications equipment. The interference ceiling shall not exceed 3.0 volts per meter measured over the usable bandwidth of the telecommunications cabling. Cabling shall be run with horizontal and vertical cable guides in telecommunications spaces with terminating hardware and interconnection equipment.
3.1.1 Cabling
Install UTP, and optical fibre telecommunications cabling system as detailed in TIA-568-C.1, TIA-568-C.2, and TIA-568-C.3. Screw terminals shall not be used. Use an approved insulation displacement connection (IDC) tool kit for copper cable terminations. Do not exceed manufacturers' cable pull tensions for copper and optical fibre cables. Provide a device to monitor cable pull tensions. Do not exceed 110 N pull tension for four pair copper cables. Do not chafe or damage outer jacket materials. Use only lubricants approved by cable manufacturer. Do not over cinch cables, or crush cables with staples.
For UTP cable, bend radii shall not be less than four times the cable diameter. Cables shall be terminated; no cable shall contain unterminated elements. Cables shall not be spliced. Label cabling in accordance with paragraph LABELING in this section.
3.1.1.1 Open Cable
Use where indicated on plans in cable trays. Install in accordance with TIA-568-C.1, TIA-568-C.2 and TIA-568-C.3. Do not exceed cable pull tensions recommended by the manufacturer. Copper cable not in a wireway or pathway
Section 27 10 00 Page 14
AMENDMENT 0004
shall be suspended a minimum of 300 mm above ceilings by cable supports no greater than 750 mm apart. Cable shall not be run through structural members or in contact with pipes, ducts, or other potentially damaging items. Placement of cable parallel to power conductors shall be avoided, if possible; a minimum separation of 300 mm shall be maintained when such placement cannot be avoided
Plenum cable shall be used where open cables are routed through plenum areas. Plenum cables shall comply with flammability plenum requirements.
3.1.1.2 Backbone Cable
a. Optical fibre Backbone Cable. Install intrabuilding backbone optical fibre in indicated pathways. Do not exceed manufacturer's recommended bending radii and pull tension. Prepare cable for pulling by cutting outer jacket 250 mm leaving strength members exposed for approximately 250 mm. Twist strength members together and attach to pulling eye.
Vertical cable support intervals shall be in accordance with manufacturer's recommendations.
3.1.1.3 Horizontal Cabling
Install horizontal cabling as indicated on drawings Do not untwist Category 6 UTP cables more than 12 mm from the point of termination to maintain cable geometry. Provide slack cable in the form of a figure eight (not a service loop) on each end of the cable, 3 m in the telecommunications room, and 304 mm in the work area outlet..
3.1.2 Pathway Installations
Provide in accordance with TIA-569. Provide building pathway as specified in Section 26 20 00 INTERIOR DISTRIBUTION SYSTEM.
3.1.3 Service Entrance Conduit, Underground
Provide service entrance underground as specified in Section 26 20 00
INTERIOR DISTRIBUTION SYSTEM.
3.1.4 Cable Tray Installation
Install cable tray as specified in Section 26 20 00 INTERIOR DISTRIBUTION
SYSTEM.
3.1.5 Work Area Outlets
3.1.5.1 Terminations
Terminate UTP cable in accordance with TIA-568-C.1, TIA-568-C.2 and wiring configuration as specified. Terminate fibre optic cables in accordance with
TIA-568-C.3
3.1.5.2 Cover Plates
As a minimum, each outlet/connector shall be labeled as to its function and a unique number to identify cable link in accordance with the paragraph LABELING in this section.
Section 27 10 00 Page 15
AMENDMENT 0004
3.1.5.3 Cables
Unshielded twisted pair and fibre optic cables shall have a minimum of 304 mm of slack cable loosely coiled into the telecommunications outlet boxes.
Minimum manufacturer's bend radius for each type of cable shall not be exceeded.
3.1.5.4 Pull Cords
Pull cords shall be installed in conduit serving telecommunications outlets that do not have cable installed.
3.1.6 Telecommunications Space Termination
Install termination hardware required for Category 6e and optical fibre system. An insulation displacement tool shall be used for terminating copper cable to insulation displacement connectors.
3.1.6.1 Connector Blocks
Connector blocks shall be rack mounted in orderly rows and columns.
Adequate vertical and horizontal wire routing areas shall be provided between groups of blocks. Install in accordance with industry standard wire routing guides in accordance with TIA-569.
3.1.6.2 Patch Panels
Patch panels shall be mounted in equipment racks with sufficient ports to accommodate the installed cable plant plus 25 percent spares.
a. Copper Patch Panel. Copper cable entering a patch panel shall be secured to the panel with cable ties as recommended by the manufacturer to prevent movement of the cable.
b. Fibre Optic Patch Panel. Fibre optic cable loop shall be 900 mm in length. The outer jacket of each cable entering a patch panel shall be secured to the panel to prevent movement of the fibres within the panel, using clamps or brackets specifically manufactured for that purpose.
3.1.6.3 Equipment Support Frames
Install in accordance with TIA-569:
a. Racks, floor mounted modular type. Permanently anchor rack to the floor in accordance with manufacturer's recommendations.
3.1.7 Electrical Penetrations
Seal openings around electrical penetrations through fire resistance-rated wall, partitions, floors, or ceilings with fire-stopping material packed into the gap between the service and wall, floor or ceiling in a manner, and compressed to the same degree, as adopted by for ISO 540 testing.
3.1.8 Earthing and Bonding
Section 27 10 00 Page 16
AMENDMENT 0004
Provide in accordance with TIA-607 and as specified in Section 26 20 00
INTERIOR DISTRIBUTION SYSTEM.
3.2 LABELING
3.2.1 Labels
Provide labeling in accordance with TIA-606. Handwritten labeling is unacceptable. Stenciled lettering for voice and data circuits shall be provided using thermal ink transfer process or laser printer.
3.2.2 Cable
Cables shall be labeled using color labels on both ends with identifiers in accordance with TIA-606.
3.2.3 Termination Hardware
Workstation outlets and patch panel connections shall be labeled using color coded labels with identifiers in accordance with TIA-606.
3.3 FIELD APPLIED PAINTING
Paint electrical equipment as required to match finish of adjacent surfaces or to meet the indicated or specified safety criteria. Painting shall be as specified in Section 09 90 00 PAINTS AND COATINGS.
3.4 FIELD FABRICATED NAMEPLATE MOUNTING
Provide number, location, and letter designation of nameplates as indicated.
Fasten nameplates to the device with a minimum of two sheet-metal screws or two rivets.
3.5 TESTING
3.5.1 Telecommunications Cabling Testing
Perform telecommunications cabling inspection, verification, and performance tests in accordance with TIA-568-C.1, TIA-568-C.2, and TIA-568-C.3. Test equipment shall conform to TIA-1152. Perform optical fibre field inspection tests via attenuation measurements on factory reels and provide results along with manufacturer certification for factory reel tests. Remove failed cable reels from project site upon attenuation test failure.
3.5.1.1 Inspection
Visually inspect UTP and optical fibre jacket materials for third party certification markings. Inspect cabling terminations in telecommunications rooms and at workstations to confirm color code for T568A or T568B pin assignments, and inspect cabling connections to confirm compliance with TIA- 568-C.1, TIA-568-C.2, and TIA-568-C.3. Visually confirm Category 6e, marking of outlets, cover plates, outlet/connectors, and patch panels.
3.5.1.2 Verification Tests
UTP backbone copper cabling shall be tested for DC loop resistance, shorts, opens, intermittent faults, and polarity between conductors, and between
Section 27 10 00 Page 17
AMENDMENT 0004
conductors and shield, if cable has overall shield. Test operation of shorting bars in connection blocks. Test cables after termination but prior to being cross-connected.
For single-mode optical fibre, perform optical fibre end-to-end attenuation tests in accordance with TIA-568-C.3 and TIA-526-7 using Method B, OTDR for single-mode optical fibre. Perform verification acceptance tests.
3.5.1.3 Performance Tests
Perform testing for each outlet as follows:
a. Perform Category 6 link tests in accordance with TIA-568-C.1 and TIA- 568-C.2. Tests shall include wire map, length, insertion loss, NEXT, PSNEXT, ELFEXT, PSELFEXT, return loss, propagation delay, and delay skew.
b. Optical fibre Links. Perform optical fibre end-to-end link tests in accordance with TIA-568-C.3.
3.5.1.4 Final Verification Tests
Perform verification tests for UTP and optical fibre systems after the complete telecommunications cabling and workstation outlet/connectors are installed.
a. Data Tests. These tests assume the Information Technology Staff has a network installed and are available to assist with testing. Connect to the network interface device at the demarcation point. Log onto the network to ensure proper connection to the network.
-- End of Section --
6.0 6.0
.5
1.
NO
M
.SERVICES TRENCH
R6.5
R12.50
R6.50
R12.50 R12.50
R12.50
5.
C-102
SQUADRON OPERATIONS BUILDING DI
SA
BL
ED
V
EH
IC
LE
P
AR
K (2
.6 m x 5.
6m
4.5 x 4.5m COMMUNICATIONS PAD. 3.2m EXCLUSION ZONE
REALIGNMENT OF WESTERN ACCESS
ROAD TO BE DESIGNED UNDER A
SEPARATE WORKS PACKAGE.
15m CLEAR ZONE
FROM BUILDING.
10m UNOBSTRUCTED
ZONE FROM BUILDING.
STORMWATER
SWALE
STORMWATER
SWALEFLEXIBLE PAVEMENT
PROJECT 16652828
P400 WORKS
PACKAGE.
ONE WAY EXIT ONE WAY ENTRY
TN
PLAN
NORTH
A1SITE LAYOUT PLAN
SCALE: 1:200m
FINAL DESIGN SUBMITTAL
C044138No.RE G I
S T
ER
ED PRO F E S S I ON A L E NGI NEER
S TA T E O F C A L I F O R N I AC I V I L
A N T
H O N Y P E T R O C C I T T O
BU
S
BA
Y
(3 .0 m x
.0 m
CONCRETE STRIP AT MINIMUM 0.5 % GRADE
AND AT 75 mm BELOW FFL
MECHANICAL EQUIPMENT PLANT 7.5 m x 5.6 m
AND CLASS 2 FENCE AND GATE ENCLOSURE
DROP OFF ZONE
x L
IG
HT
V
EH
IC
LE
P
AR
K (2
.6 m x 5.
6m
PRECAST REINFORCED CONCRETE
HEADWALL
ROCK LINED ON GEOTEXTILE FABRIC
OUTLET AND INLET PROTECTION
KERB RAMP. REFER TYPICAL
DETAIL ON DRAWING C504
3x M
IN
I B
US
P
AR
KS
(2 .9 m x
9.
0m
PEDESTRIAN
ACCESS PATH
FLUSH KERB
RAISED KERB
EXISTING SURFACE DRAINAGE DIRECTION
STOP LINE
EDGE LINE
REFER TO DRAWING C503 FOR FENCING
DETAILS AND CONNECTION POINT. FINAL
ALIGNMENT TO BE CONFIRMED ON SITE AND
APPROVED BY CONTRACT ADMINISTRATOR
20000mm
1:200
100000
SHEET LEGEND:
2.50m
2.
m
BOLLARDS LOCATION AS PER ARCHITECTURAL
DRAWINGS. AS PER DETAIL ON DRAWING C-502
C1 C-311
C1 C-311
A1 C-311
A1 C-311
FFL 131.0m
WASTE ZONE
REFER TO DRAWING C503 FOR FENCING
DETAILS AND CONNECTION POINT. FINAL
ALIGNMENT TO BE CONFIRMED ON SITE AND
APPROVED BY CONTRACT ADMINISTRATOR
D3 C502
D1 C502
WHEEL STOPS (TYP)
AIRSIDE FENCE REFER DRAWING C-503/
NEW ASPHALT PAVEMENT AREA REFER TO DRAWING
C-505 FOR DETAILS
NEW 100MM THICK CONCRETE FOOTPATH, SL72 MESH,
REFER TO DRAWING C-504 FOR DETAILS
PROVIDE SECURITY
AND TRASH SCREEN
WESTERN ACCESS ROAD
L
EG
EN
D
UP
DA
TE
D
.0
6.
C S
P400 AIRSIDE FENCE REFER DRAWING C-503
Evan Mizue
13 JULY 2023
SVCV
SV
CV
C1
C1
C1 C
C C
C C
C C
C C
C
C C
C C
C C
C C
C C
C C
C
C
C
C1
C1
C
C
C1 C
C
T
T
T
W
W
W
W W
W W
W
S
S
HM
HM
HM
C C
C C
C C C C C C
C
C
C
C
C
C
C C
C C
C C
C C
C C
C C
C C
C C
C C
C C
C C
CC E
C
C C
C C
E
E
C
C
E E
E
E2 EE
E
E
E
EE
E E
E E
E E
E
E2
E2
E2
C-121
C044138No.
AIRCRAFT MAINTENANCE
STORAGE FACILITY
SQUADRON OPERATIONS BUILDING
4.5 x 4.5m COMMUNICATIONS PAD. 3.2m EXCLUSION ZONE
COMMUNICATION CONNECTION POINT
PROVIDED BY THE KC30 PROJECT
REFER TO THE ELECTRICAL
DRAWINGS FOR DETAILS.
DOMESTIC WATER SUPPLY CONNECTION POINT
PROVIDED BY THE KC30 PROJECT AT IL 129.81. WATER
METER IS IN ACCORDANCE WITH PWC STD DRG
W1-1-01A.
CH 0.00
NEW TYPE 2 SEWER
CONNECTION IN ACCORDANCE
WITH PWC STD DRG W2-1-02
CH 0.00
IL 127.10
TEE
CH 34.10
DOMESTIC WATER SUPPLY BRANCH
TO P400 LINE 2 TO BE PROVIDED BY
P400 PROJECT. LINE TO BE CAPPED
IF P400 LINE 2 IS IMPLEMENTED
PRIOR TO P700 LINE 1.
REFER TO DRAWING E101 FOR
ELECTRICAL CONDUIT AND
CABLING DETAILS.
REFER TO DRAWING E101 FOR
COMMUNICATIONS CONDUIT
AND CABLING DETAILS.
DOMESTIC WATER SUPPLY
BRANCH TO P400 & P700
LINE 1
90° BEND
CH 4.50
BUILDING
CONNECTION
CH 0.00
IL 129.84
INSPECTION OPENING (IO)
CH 0.42
IL 129.15
45° BEND WITH INSPECTION
OPENING TO SURFACE (IOS)
IN ACCORDANCE WITH AS3500
CH 16.15
BUILDING CONNECTION
CH 20.06
IL 129.47
DN100 PVC SN8
DOMESTIC WATER SUPPLY
BRANCH TO P700
LINE 2
C C C C C
E E
S S
W W
E
C
SEWER UNDER
PROPOSED PAVEMENT.
REFER TO NOTE 3.
FFL 131.0m
EXISTING SEWER UNDER
PROPOSED PAVEMENT.
REFER TO NOTE 3.
EXISTING SEWER. REFER
NOTE 2.
1 8
B
F
A
VESTIBULE
GF-002
HALLWAY 1
GF-024
HALLWAY 2
GF-026
OPS DESK
GF-025
MALE
GF-005
FEMALE
GF-006
CLNR
GF-027
PWD
GF-028
BREAK
ROOM
GF-008
VESTIBULE
GF-010
OPS CO 1
GF-004
OPS CO 2
GF-003
GENERAL ADMIN
SUPPORT 1
GF-011
GENERAL ADMIN
SUPPORT OFFICE 2
GF-029
GENERAL ADMIN SUPP
SHARED OFFICE 3
GF-012
LSE
GF-014
SECURED
VESTIBULE
GF-034
HALLWAY 3
GF-033
MISSION
PLANNING 1
GF-017
MISSION
PLANNING 2
GF-018
CREW
MEETING 2
GF-031
CREW
MEETING 1
GF-016
DUTY OFFICER
GF-032CREW
MEETING 4
GF-020
CREW
MEETING 3
GF-019
MASS BRIEFING 2
GF-022
MASS BRIEFING 1
GF-023
MECHANICAL
ROOM
GF-007
ELECTRICAL
GF-015 MSB
MDB
LIGHTING
DB
UPS
RACK 1
AUS
SEC
FCU
ACCU
WATER
HEATER
HYDRO
PNEUMATIC
TANK
TEF /
COMMS
GF-030
MSB
DB-TEF
FDFD
ROOF LINE
DDCHB
HB
ACCU
RACK 2
USAF
RACK 1
USAF
CHAINLINK FENCE,
SEE CIVIL DWGS
CONCRETE PAD,
SEE CIVIL DWGS
CONCRETE
WALKWAY, SEE
CIVIL DWGS
FE1
FE1
FE1
FE1
FE1
FE1
FDIC
BUS DROP-OFF ZONE,
SEE CIVIL DWGS
COMMS PAD,
SEE CIVIL DWGS
CHEVRON MARKING,
SEE CIVIL DWGS
AC PAVEMENT,
SEE CIVIL DWGS
GRASSED AREA,
SEE CIVIL DWGS
GRASSED AREA,
SEE CIVIL DWGS
ACCU
ACCU DOAS
SECURED
VESTIBULE
GF-021
024A
024B
005 027 028 006 008
034033A
017A
017B 031A
033B
016019
020A
031B
020B
022A
022B
003 004A 004B
005 006
L006 L007
008A
008B
011A011B012014
3A
3A
3C 3C
3B3C
3C 3C 3C
3C
3B
5 3
2 3 4 5 6 7
34990
4628 4533 4533 3470 5730 6610 5485
246019301095
C
D
E
34990
4628 4533 4533 3470 5730 6610 5485
A5
A-401
CONCRETE SPLASH BLOCK,
TYPICAL, SEE A1
A-802
C5 A-701
B5 A-701
COUNTER, SEE
65 9001100
CG
CG
1000 4250
22003661128
A5 A-701
1600 175
00CG
CG
CG
2364172742241600
CG
CG
530 530
3050 920
190 4210 228 1075 1572 1885 2390 2364
E
N
A-401 D1
ACCU
RAMP, SEE CIVIL DWGS
3D
5A
CG CG
CG CG
CG
CG
GF-X001
COVERED ENTRY
GF-X009
COVERED ENTRY 2
GF-X013
ENCLOSURE
MECHANICAL
FD FD
FD FS
FD
3740 10050 3184 568 2200 1740 1306 1000 2542 1720 96 1000 507 294 1000 1000 1000 590
2340 3020 3475
1036 1000 600 1000 600 100010341930
43154315
GF-X009
COVERED ENTRY 2
FINAL DESIGN SUBMITTAL
RO C A A
N
4-30-24
T
C
Exp.
DERE RA
I G
R E
O J
G S T
UAM
No.
C
E O
H I T EC
T
OE
I H
E
IT
S N
F
T
I
DAI
T
C DDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEERRRRRRRRRRRRRE RRRRRRRRRAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
IIIIIIIIIIIIIIIIIII
G
E
G
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS T
UAM
H I T EC
A1FLOOR PLAN
SCALE: 1:75
LEGEND:
A-101
GRAPHIC SCALE
150 SERIES CMU WALL
GYPSUM WALL BOARD ON METAL STUD
SECURE AREA (ZONE 2 FIT FOR BUT
NOT WITH ZONE 4 PROVISIONS)
TN
PLAN
NORTH
200 SERIES CMU WALL WITH
135mm THK INSULATED METAL WALL
PANEL ON EXTERIOR
SHEET LINED FURRING WALL ON
200 OR 150 SERIES CMU WALL
200 SERIES CMU WALL
FE1 WALL MOUNTED HOOK TYPE,
NO CABINET FIRE EXTINGUISHER,
SEE FIRE PROTECTION DWGS
STEEL COLUMN, SEE STRUCTURAL
NOTES:
1. REFER TO SHEET A-501 FOR WALL TYPE DETAILS
2. REFER TO I-101 FOR FURNITURE AND EQUIPMENT
PLAN/SCHEDULE.
3. DIMENSION ON INTERIOR WALLS ARE TO CENTER
OF WALL UNLESS NOTED OTHERWISE.
4. PROVIDE 50mm RECESSED FLOOR AT WET AREAS, SEE STRUCTURAL DRAWINGS.
FHR FIRE HOSE REELS,
SEE FIRE PROTECTION DWGS
# WALL TYPE TAG, SEE TYPES ON A-502
DOOR TAG, SEE DOOR SCHEDULE &
TYPES ON SHEET A-601
WINDOW TAG, SEE WINDOW SCHEDULE
& TYPES ON SHEET A-601
CHANGE IN FINISH FLOOR ELEVATION,
SEE DETAIL B5/A-801
CORNER GUARD, SEE LIST OF
MATERIALS ON SHEET A-601
CG
VESTIBULE
GF-002
HALLWAY 1
GF-024
HALLWAY 2
GF-026
OPS DESK
GF-025
MALE
GF-005 FEMALE
GF-006
CLNR
GF-027
PWD
GF-028
BREAK
ROOM
GF-008
VESTIBULE
GF-010
OPS CO 1
GF-004OPS CO 2
GF-003
GENERAL ADMIN
SUPPORT 1
GF-011
GENERAL ADMIN
SUPPORT OFFICE 2
GF-029
GENERAL ADMIN SUPP
SHARED OFFICE 3
GF-012
LSE
GF-014
SECURED
VESTIBULE
GF-034
HALLWAY 3
GF-033
MISSION
PLANNING 1
GF-017
MISSION
PLANNING 2
GF-018
CREW
MEETING 2
GF-031
CREW
MEETING 1
GF-016
DUTY OFFICER
GF-032
CREW
MEETING 4
GF-020
CREW
MEETING 3
GF-019
MASS BRIEFING 2
GF-022
MASS BRIEFING 1
GF-023
MECHANICAL
ROOM
GF-007
TEF /
COMMS
GF-030
ROOF LINE
ELECTRICAL
GF-015
SECURED
VESTIBULE
GF-021
82 3 4 5 6 7
34990
4628 4533 4533 3470 5730 6610 5486
34990
4628 4533 4533 3470 5730 6610 5486
190190
896 4590
B
A4 A-802
C4 A-802
B5 A-802
ACCESS PANEL,
SEE
D3 A-802
D5 A-801
D5 A-801
D5 A-801
D5 A-801
PRESSED STEEL GUTTER,
TYPICAL, SEE C1
A-802
A
C
D
E
F
D4 A-802
B4 A-802
1662 400 2471
3992 675
653 1147 1361
EQ
EQ 89
448448 550 1000 1000 1000 475
0 1030
825 1800 1800
286 8630
610 967 634
1307 517
6511840
6051017524
45 670
1409136546
415610 6301140
1024 43
825 825
1853 2462 2462
FINAL DESIGN SUBMITTAL
RO C A A
N
4-30-24
T
C
Exp.
DERE RA
I G
R E
O J
G S T
UAM
No.
C
E O
H I T EC
T
OE
I H
E
IT
S N
F
T
I
DAI
T
C DDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEERRRRRRRRRRRRRE RRRRRRRRRAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
IIIIIIIIIIIIIIIIIII
G
E
G
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS T
UAM
H I T EC
A1REFLECTED CEILING PLAN
SCALE: 1:75
A-102
GRAPHIC SCALE
TN
PLAN
NORTH
LEGEND:
600mm x 1200mm ACOUSTICAL CEILING TILE
SEE DETAIL C5 & D3/A-802
13mm THK PLASTERBOARD CEILING, FULLY TAPED AND SET, PAINT FINISH, USE WATER-RESISTANT ON WET AREAS;
SEE D4/A-802
LIGHT FIXTURE,
SEE ELECTRICAL
SUPPLY AIR REGISTER,
SEE MECHANICAL
EXHAUST AIR REGISTER,
SEE MECHANICAL
EXIT SIGN LIGHT,
SEE ELECTRICAL
600mm x 600mm ACCESS PANEL, SEE B5/A-802 FOR DETAILS
0.42 BMT MINI ORB LINING, PRE-FINISHED,
OFF-WHITE
NOTE:
1. SEE SHEET A-601 FOR CEILING HEIGHT AND FINISHES
RETURN AIR REGISTER,
SEE MECHANICAL
SECURE AREA (ZONE 2 FIT FOR BUT
NOT WITH ZONE 4 PROVISIONS)
| pdp8577 |
| Tindal P700 Amendment 4 |
| 27 10 00 P700 |
| P700_AMEND4_PLANS_sign_flat |