1665827-P-700 Drawings - 2 of 2.pdf
PDF 23 MB Posted
- Attached to
- FY22 MCAF PAF180700 SQUADRON OPERATIONS FACILITY, ROYAL AUSTRALIAN AIR FORCE BASE TINDAL, AUSTRALIA
- Solicitation number
- N6274223R1316
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 23R1316 Note 6.pdf | ||
| 23R1316_AMD6.pdf | ||
| 23R1316_AMD5.pdf | ||
| 23R1316 Note 5.pdf | ||
| 23R1316_AMD4.pdf | ||
| 23R1316 Note 4.pdf | ||
| 23R1316 AMD3.pdf | ||
| 23R1316_AMD2.pdf | ||
| 23R1316 Note 3.pdf | ||
| P700 SV Sign-in.pdf | ||
| 23R1316_AMD1.pdf | ||
| 23R1316 Note 2.pdf | ||
| 23R1316 Note 1.pdf | ||
| 1665827-P700 Specification_Signed_REV_MAY2023.pdf | ||
| 1665827-P-700 Drawings - 1 of 2.pdf | ||
| 23R1316-RFP.pdf |
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 2 3 4 5 6 87
F
B
A
E
D
C
S-105
C044138No.
DATE: 03/17/2023
Evan Mizue
1 2 3 4 5 6 87
FBA EDC
B
S-201
C044138No.
FIXING DESIGN OF THE INSULATED METAL PANELS SHALL BE BY THE
SUPPLIER / BUILDER. SUBMIT TO THE CONTRACTING OFFICER FOR REVIEW.
ABCDEF
ABCDEF
ABCDEF
S-202
C044138No.
PLAN - TEE
4-N16 'L' BARS (TOP &
BTM) LAPPED WITH
LONGITUDINAL BARS
GROUND BEAM
REINFORCING
AS SPECIFIED
PLAN - CORNER
3-N16 'L' BARS (BTM)
LAPPED WITH
LONGITUDINAL BARS
BP
IJ
R8-200
S-301
C044138No.
CHEMICAL WATERPROOFING
TO FIRST COURSE. REFER
DETAILS ON DRAWING S-301.
S-401
C044138No.
NOTE: TRUSS HOLD-DOWN BOLT LOCATIONS TO ALIGN WITH ENGAGED PIERS IN
BLOCKWORK WALL, AS DETAILED ON DRAWING S-102.
OR1
S-501
C044138No.
D
S-502
C044138No.
E-001
SCHEMATICS
CONTACTOR
CIRCUIT BREAKER
EARTH
METER
SURGE DIVERTER
MEN LINK
M
SEC
ABBREVIATIONS
AB ABOVE BENCH
AD ABOVE DOOR
ACCU AIR COOLED CONDENSER UNIT
BP BOOSTER PUMP
CHIL CHILLER
DOAS DEDICATED OUTDOOR AIR SYSTEM
EF EXHAUST FAN
EWH INSTANTANEOUS WATER HEATER
FCU FAN COIL UNIT
FDCIE FIRE DETECTION CONTROL AND INDICATING EQUIPMENT
FR FRIDGE
HD HAND DRYER
HTC HYDRONEUMATIC TANK COMPRESSOR
HWU HOT WATER UNIT
MW MICROWAVE
OWS OCCUPANT WARNING SYSTEM
PA PUBLIC ADDRESS
POC POINT OF CONNECTION
SMOF SINGLEMODE FIBRE OPTIC
TX TRANSFORMER
WWP WASTE WATER PUMP
COMMUNICATIONS
DATA OUTLET
2 DENOTES DOUBLE OUTLET
COMMUNICATIONS RACK (CLASS C RACK FOR AUSTRALIAN CABINETS)
1x300mm COMMUNICATIONS CABLE TRAY
AUSTRALIAN - UNSECURED
1x300mm COMMUNICATIONS CABLE TRAY
USAF - UNSECURED
1x300mm COMMUNICATIONS CABLE TRAY
USAF - SECURED
1x300mm COMMUNICATIONS CABLE TRAY SECURITY
COMMUNICATION CONDUITS
SECURITY CONDUITS
LOCKABLE COMMUNICATIONS PIT
CLASS D PIT MIN 1250mm x 450mm x 950mm. SCEC
ENDORSED WITH SCEC ENDORSED LID. UNLESS
SPECIFICALLY STATED DIFFERENTLY ON DRAWING.
CONTRACTOR TO SUPPLY ALL NECESSARY
ANCILLARY EQUIPMENT.
LIGHTING
23W 2418 lm RECESSED PANEL 4000K, IP54
45W 4500 lm SURFACE MOUNTED BATTEN 4000K, IP65
12W/m 320lm/m LINEAR LED, 4000K, IP67
TO BE MOUNTED IN COVE IN BATHROOMS. LENGTHS SHOWN
ON E131.
19.6W 2050 lm LED RECESSED DOWNLIGHT 4000K IP44
12W 1000 lm EXTERIOR BULKHEAD WALL LIGHT 4000K, IP 66, IK10, PROVIDE ANY NECESSARY SHIELD ACCESSORY TO
PREVENT OBTRUSIVE UPLIGHT.
6200lm 60W LED STREET LIGHT ON 6m POLE, IP66, IK09, 4000K WITH LIGHTING DISTRIBUTION ST1.2a (WIDE DISTRIBUTION)
POLE TO BE TAPERED, GALVANISED AND EQUIPPED WITH
SERVICE DOOR. POLE FOOTING TO MANUFACTURERS
REQUIREMENTS. ENSURE FITTING PROVIDES APPROPRIATE
LIGHTING COVERAGE AT 0 DEGREE TILT ANGLE.
11424lm 86W LED STREET LIGHT ON 6m POLE, IP66, IK09, 4000K, 80CRI WITH LIGHTING DISTRIBUTION TYPE III MEDIUM.
POLE TO BE TAPERED, GALVANISED AND EQUIPPED WITH
SERVICE DOOR. POLE FOOTING TO MANUFACTURERS
REQUIREMENTS.ENSURE FITTING PROVIDES APPROPRIATE
LIGHTING COVERAGE AT 0 DEGREE TILT ANGLE.
360° MOTION DETECTOR
PE CELL
L1
L2
D1
W1
LIGHTNING PROTECTION
AIR TERMINAL, 600mm IN LENGTH
EARTH ELECTRODE
AIR TERMINAL CONDUCTOR
DOWN CONDUCTOR
EARTH RING CONDUCTOR
EARTH PIT
MAIN EARTH PIT
NOTES
1. DRAWINGS ARE TO BE READ IN CONJUNCTION WITH
THE ELECTRICAL SPECIFICATION AND MIEE
DOCUMENTS.
2. DRAWINGS ARE TO BE READ IN CONJUNCTION WITH
OTHER SERVICES DRAWINGS, INCLUDING BUT NOT
LIMITED TO: STRUCTURAL, CIVIL, MECHANICAL,
HYDRAULIC (PLUMBING), ARCHITECTURE.
SWITCHTING
SWITCH WIRE(NON-ESSENTIAL)
SINGLE 10A LIGHT SWITCH - 1100 AFFL
SINGLE 10A LIGHT SWITCH W/ 1-10V DIGITAL DIMMER - 1100
AFFL
SECURITY
ACCESS PANEL
SECURITY PANEL
SPEAKERS
C C
C
CT1
CT2
CT3
L3
CT4
P1
P2
S
ELECTRICAL SYMBOLS LEGEND ELECTRICAL GENERAL NOTES
E16929No.
POWER
SINGLE 10A SWITCHED SOCKET OUTLET (SSO)
DOUBLE 10A SWITCHED SOCKET OUTLET (DSO)
ISOLATOR. N DENOTES NO. OF POLES. A DENOTES
CURRENT CAPACITY
DISTRIBUTION BOARD (DB)
MAIN SWITCHBOARD (MSB)
MECHANICAL SERVICES SWITCHBOARD (MSSB)
xN,xA
FLOOR BOX (FLUSH, STAINLESS STEEL BOX LID)
2 x DOUBLE GPO 2 x DOUBLE DATA
1x300mm CABLE TRAY
(UNISTRUT SUPATRAY ST3 AUG2A330 OR APPROVED EQUAL)
ELECTRICAL CABLE PIT
TYPE 99 900mm X 900mm WITH CLASS D LID UNLESS SPECIFICALLY
STATED DIFFERENTLY ON DRAWING - SUPPLY ACO PIT RISER TO
ALLOW CONDUITS TO ENTER PIT AT 600mm BELOW GROUND
ELECTRICAL CABLE PIT
TYPE 33 353mm X 353mm x 444mm WITH CLASS D UNLESS SPECIFICALLY
STATED DIFFERENTLY ON DRAWING - SUPPLY ACO PIT RISER TO
ALLOW CONDUITS TO ENTER PIT AT 600mm BELOW GROUND
ELECTRICAL CONDUITS
EMERGENCY & EXIT LIGHTING
EMERGENCY EXIT SIGN (STRAIGHT AHEAD). SUFRACE MOUNTED.
24M VIEWING DISTANCE.
DS DENOTES DOUBLE SIDED.
EMERGENCY EXIT SIGN (DIRECTIONAL). SUFRACE MOUNTED.
24M VIEWING DISTANCE.
DS DENOTES DOUBLE SIDED.
EMERGENCY LIGHT (RECESSED)
C0: D40 C90: D40
EMERGENCY LIGHT (SURFACE MOUNTED)
C0: D40 C90: D40
E
E2
E
EN
WALL
CONSTRUCTION
INSTALLATION AND
CONCEALED
CABLING FACILITES
RENDERED MASONARY
PARTITION
SURFACE MOUNTED BOX WITH CONDUIT CHASED
INTO WALL
FACE BRICK EXTERNAL
CAVITY WALL
SURFACE MOUNTED BOX WITH THERMOPLASTIC
INSULATED CABLES IN CONDUIT RUN IN CAVITY AND
TIED AGAINST INNER BRICK SURFACE, OR
THERMOPLASTIC SHEATHED CABLES RUN IN CAVITY
STUD PARTITION REWIRABLE
1.GENERAL
1.1 ADDITIONAL WORK
QUALITY
WORKS BEYOND THE SCOPE OF THIS SPECIFICATION: TO THE GENERAL QUALITY
OF THIS FITOUT SPECIFICATION.
1.2 AUTHORITIES
COMPLIANCE
CONFORM TO THE FOLLOWING:
THE BUILDING CODE OF AUSTRALIA.
ANY BUILDING APPROVALS.
THE REQUIREMENTS OF LOCAL AND STATE OR TERRITORY GOVERNMENT
AUTHORITIES.
THE RELEVANT REQUIREMENTS OF THE AUSTRALIAN DEPARTMENT OF
DEFENCE.
SPECIFICATIONS
MIEE & MFPE
ELECTRICAL WORKS: USE ONLY STATE OR TERRITORY LICENSED PERSONNEL.
2.EXECUTION
2.1 SERVICES INSTALLATION
PENETRATIONS AND FIXING
FIXING: IF EQUIPMENT IS NOT SUITABLE FOR FIXING TO NON-STRUCTURAL
BUILDING ELEMENTS, FIX DIRECTLY TO STRUCTURE AND TRIM AROUND HOLES
OR PENETRATIONS IN NON-STRUCTURAL ELEMENTS.
GENERAL: IF IT IS PROPOSED TO PENETRATE OR FIX TO THE FOLLOWING,
SUBMIT DETAILS OF THE METHODS PROPOSED TO MAINTAIN THE REQUIRED
STRUCTURAL, FIRE AND OTHER PROPERTIES:
STRUCTURAL BUILDING ELEMENTS INCLUDING EXTERNAL WALLS, FIRE
WALLS, FIRE DOORS AND ACCESS PANELS, OTHER TESTED AND RATED
ASSEMBLIES OR ELEMENTS, FLOOR SLABS AND BEAMS.
MEMBRANE ELEMENTS INCLUDING DAMP-PROOF COURSES,
WATERPROOFING MEMBRANES AND ROOF COVERINGS. IF PENETRATING
MEMBRANES, PROVIDE A WATERPROOF SEAL BETWEEN THE MEMBRANE
AND THE PENETRATING COMPONENT.
FIRE RATED BUILDING ELEMENTS: SEAL PENETRATIONS WITH A SYSTEM
CONFORMING TO AS 4072.1.
NON-FIRE RATED BUILDING ELEMENTS: SEAL PENETRATIONS AROUND
CONDUITS AND SLEEVES. SEAL AROUND CABLES WITHIN SLEEVES. IF THE
BUILDING ELEMENT IS ACOUSTICALLY RATED, MAINTAIN THE RATING.
PIPE SLEEVES: IF PIPING OR CONDUIT PENETRATES BUILDING ELEMENTS,
PROVIDE METAL OR PVC SLEEVES FORMED FROM OVERSIZE PIPE SECTIONS.
ALL WIRING AND CABLING SHALL BE CONCEALED WITHIN WALLS, CEILING VOIDS
AND FINISHES. ACCESSORIES AND CONDUITS MUST BE INSTALLED AS SURFACE
MOUNTED.
2.2 COMPLETION
PROJECT FOLDER
PROVIDE A PROJECT FOLDER CONTAINING THE FOLLOWING:
• RECORD DRAWINGS OF WORKS AS BUILT.
• PRODUCT DATA WITH MAINTENANCE AND CLEANING INSTRUCTIONS.
• PRODUCT WARRANTIES
ELECTRICAL INSTALL
1.GENERAL
1.1 RESPONSIBILITIES
QUALIFICATION
GENERAL: USE ONLY PERSONS APPROPRIATELY EXPERIENCED AND QUALIFIED
TO UNDERTAKE THE ELECTRICAL DESIGN WORK ON THE SYSTEMS
DOCUMENTED.
PERFORMANCE GENERAL: CARRY OUT VERIFICATION TESTS AND
MEASUREMENTS TO SHOW COMPLIANCE WITH THE SPECIFICATION.
1.2 STANDARDS
GENERAL
ELECTRICAL SYSTEMS: TO AS/NZS 3000 AND SAA HB 301.
TELECOMMUNICATIONS CABLING: TO AS/ACIF S008, AS/ACIF S009, AS/NZS 3080
AND SAA HB 29, MANUAL OF INFRASTRUCTURE ENGINEERING - ELECTRICAL
(MIEE).
DEGREES OF PROTECTION (IP CODE): TO AS 60529.
EMC: TO AS/NZS 61000.
EMERGENCY LIGHTING: TO ASS 2293
2. EXECUTION
2.1 GENERAL
LOCATION
ARRANGEMENT: ARRANGE SERVICES SO THAT SERVICES RUNNING TOGETHER
ARE PARALLEL WITH EACH OTHER AND WITH ADJACENT BUILDING ELEMENTS.
FIXING: IF NON-STRUCTURAL BUILDING ELEMENTS ARE NOT SUITABLE FOR
FIXING EQUIPMENT AND SERVICES TO, FIX DIRECTLY TO STRUCTURE AND TRIM
AROUND HOLES OR PENETRATIONS IN NON-STRUCTURAL ELEMENTS.
INSTALLATION: ACCESSORIES AND CONDUITS MUST BE INSTALLED AS SURFACE
MOUNTED. INSTALL EQUIPMENT AND SERVICES PLUMB, FIX SECURELY AND
ORGANISE RETICULATED SERVICES NEATLY. ALLOW FOR MOVEMENT IN BOTH
STRUCTURE AND SERVICES.
2.2 INSTALLATION OF ACCESSORIES
GENERAL
ACCESSORIES: INSTALL ACCESSORIES IN CONFORMANCE WITH THE
INSTALLATION OF ACCESSORIES TABLE.
FLUSH MOUNTING: PROVIDE FLUSH MOUNTED ACCESSORIES.
LOCATION: CONFIRM THE FINAL LOCATION OF ALL OUTLETS AND EQUIPMENT ON
SITE PRIOR TO INSTALLATION.
DEFAULT MOUNTING HEIGHTS TO CENTRE OF ACCESSORY PLATE:
OUTLETS NOT ON SKIRTING DUCT – 300mm SWITCHES AND CONTROLS – 1100mm
RESTRICTED LOCATION: DO NOT INSTALL WALL BOXES ACROSS JUNCTIONS OF
WALL FRAMES INSTALLATION OF ACCESSORIES TABLE
INSTALLATION OF CEILING MOUNTED APPLIANCES
CONNECTIONS – APPLIANCES: PROVIDE FLUSH MOUNTED OUTLETS ON THE
CEILING NEXT TO SUPPORT BRACKETS.
CONNECTIONS – FIXED EQUIPMENT: PROVIDE CONCEALED PERMANENT
CONNECTIONS.
FIXING: PROVIDE SUPPORT BRACKETS FIXED THROUGH CEILING TO THE
BUILDING STRUCTURE. BRACE APPLIANCES THAT HAVE EXCESSIVE BENDING
MOMENTS, ARE HEAVY OR VIBRATE, TO PREVENT HORIZONTAL MOVEMENT.
2.3 LOW VOLTAGE POWER SYSTEMS
GENERAL
GENERAL: DESIGN AND INSTALL FINAL SUBCIRCUITS TO ALL POWER AND
LIGHTING LOADS. COORDINATE WITH ALL OTHER TRADES FOR POWER SUPPLY
AND CABLE CONDUIT / DUCTING REQUIREMENTS, REFER TO MECHANICAL,
HYDRAULIC AND COMMUNICATIONS DESIGN DOCUMENTATION.
SUBMISSIONS
TECHNICAL DATA: SUBMIT DOCUMENTATION TO FULLY DESCRIBE THE
PROPOSED INSTALLATION. AS A MINIMUM PROVIDE:
SINGLE LINE DIAGRAM,
CERTIFY COMPLIANCE WITH AS/NZS 3000, FOR ELECTRICAL SERVICES.
CIRCUIT SCHEDULES / DB SCHEDULES
ACCESSORIES
GENERAL: PROVIDE, AND AS NECESSARY, RELOCATE THE FOLLOWING:
GENERAL POWER OUTLETS.
ISOLATING SWITCHES.
PROVIDE ALL SOFT WIRING FROM SKIRTING DUCT TO TABLE BOXES
WIRING SYSTEMS
STANDARD: TO AS/NZS 3013.
THERMAL INSULATION: IN WALLS FILLED WITH THERMAL INSULATION, INSTALL
CABLES IN PVC CONDUIT.
POWER CABLES
GENERAL: COPPER CABLE GENERALLY, MULTI-STRANDED. MINIMUM SIZE:
LIGHTING SUBCIRCUITS: 2.5mm2 POWER SUBCIRCUITS: 4mm2 .
FAULT LOOP IMPEDANCE: PROVIDE FINAL SUBCIRCUIT CABLES SELECTED TO
SATISFY THE REQUIREMENTS FOR AUTOMATIC DISCONNECTION UNDER
SHORT-CIRCUIT AND EARTH FAULT/TOUCH VOLTAGE CONDITIONS.
2.4 SWITCHBOARD COMPONENTS
GENERAL: PROVIDE PROPRIETARY SWITCHBOARDS TO THE FOLLOWING AND AS
DOCUMENTED.
STANDARDS
STANDARD: TO MIEE CHAPTER 11 & AS/NZS 61439.1
DOORS
GENERAL: PROVIDE LOCKABLE DOORS WITH A CIRCUIT CARD HOLDER UNLESS
ENCLOSED IN CUPBOARDS OR IN AN AREA WHICH IS NOT READILY ACCESSIBLE
TO THE PUBLIC.
FINISHES
INTERIOR: WHITE.
EXTERIOR: MANUFACTURERS STANDARD FINISH.
VENTILATION
GENERAL: REQUIRED TO MAINTAIN DESIGN OPERATING TEMPERATURES AT FULL
LOAD.
DISTRIBUTION BOARD COMPONENTS
PROTECTIVE DEVICES
GENERAL: SELECT AND ADJUST PROTECTIVE DEVICES TO GRADE AND
COORDINATE FOR OVERCURRENT, AND EARTH FAULTS.
REQUIREMENT: AS NECESSARY PROVIDE PROTECTIVE DEVICES WHICH GRADE
AND COORDINATE FOR OVERCURRENT, LET THROUGH ENERGY, AND EARTH
FAULTS.
MOULDED CASE AND MINIATURE CIRCUIT BREAKERS
MOULDED CASE BREAKERS: TO AS/NZS 60947.1, AS 2184 AND AS 60947.2.
MINIATURE CIRCUIT BREAKERS: TO AS/NZS 60898.1 OR AS 3111.
TRIP TYPE
FAULT CAPACITY > 10 KA: TO AS 60947.2 AND AS/NZS 60947.1.
FAULT CAPACITY < 10 KA, CURRENT RATING < 100 A: MINIATURE OVERCURRENT
CIRCUIT BREAKERS TO AS/NZS 60898.1 OR AS 3111 CLIP TRAY CHASSIS.
FOR MINIATURE OVERCURRENT CIRCUIT BREAKERS PROVIDE CLIP TRAY
ASSEMBLIES CAPABLE OF ACCEPTING SINGLE, DOUBLE, OR TRIPLE CIRCUIT
BREAKERS, AND RELATED BUSBARS. PROVIDE MOULDED CLIP-ON POLE FILLERS
FOR UNUSED PORTIONS.
RESIDUAL CURRENT DEVICES
INTEGRAL TYPE: INCORPORATE EARTH LEAKAGE IN CIRCUIT BREAKER
PROTECTION OPERATION TO AS/NZS 61009.1.
MAXIMUM TRIPPING CURRENT: 30 mA.
CONTACTORS
STANDARD: TO AS/NZS 60947.4.1.
RATED OPERATIONAL CURRENT: FULL LOAD CURRENT OF THE LOAD
CONTROLLED.
MINIMUM RATING: 16 A.
2.5 LIGHTING
SCOPE
SCOPE: LIGHTING AND LIGHTING CONTROL HAVE BEEN DESIGNED AND
SPECIFIED TO AS 1680, AS 1158, BCA 2019 AND MIEE CHAPTER , CONSIDERING
ENERGY EFFICIENCY, PERFORMANCE, ESD AND ENVIRONMENTAL IMPLICATIONS.
GENERAL
GENERAL: CONTRACTOR TO SUPPLY AND INSTALL NEW LIGHTING AS REQUIRED
TO SUIT SPECIAL FUNCTIONAL REQUIREMENTS.
INTERIOR LIGHTING STANDARD: TO AS/NZS 1680 PARTS 1, 2.1, 2.2, AS 1680.3 AND
AS1680.5.
PROPRIETARY EQUIPMENT: PROVIDE ONLY PROPRIETARY LUMINAIRES, FITTINGS
AND ACCESSORIES.
MINIMUM ENERGY PERFORMANCE STANDARDS
GENERAL: TO AS/NZS 4783.2 AND AS/NZS 4782.2.
LAMPS
LAMPS: PROVIDE ALL LUMINAIRES COMPLETE WITH LAMPS AND ACCESSORIES.
VERIFY OPERATION: INSTALL LAMPS IN ALL LUMINAIRES AND VERIFY CORRECT
OPERATION BEFORE COMPLETION.
COLOUR RENDERING: GROUP 1B TO AS/NZS 1680.1.
COLOUR CORRECTED TEMPERATURE: 4000°K.
LOW VOLTAGE LAMPS: PROVIDE LAMPS IN CONFORMANCE WITH THE LUMINAIRE
MANUFACTURER’S RECOMMENDATION.
INSTALLATION
SUPPORTS: MOUNT LUMINAIRES ON PROPRIETARY SUPPORTS BY MEANS OF
BATTENS, TRIMS, NOGGINGS, ROSES OR PACKING MATERIAL TO SUIT LOCATION.
RECESSED LUMINAIRES SUPPORT: TO AS 2946.
2.6 EMERGENCY AND EVACUATION LIGHTING
GENERAL
GENERAL: EMERGENCY EVACUATION LIGHTING SYSTEM TO MEET THE
REQUIREMENTS OF THE BCA. TEST AND COMMISSION IN CONFORMANCE WITH
AS/NZS 2293.
PROVIDE COMPUTER MONITOR EMERGENCY LIGHTING AND EXIT SIGNS AS
DOCUMENTED TO MEET THE REQUIREMENTS OF THE BCA AND CONNECTION
INTO SITE BMS SYSTEM. TEST AND COMMISSION IN CONFORMANCE WITH AS/NZS
2293.
LUMINAIRES
EMERGENCY EXIT SIGNS: PROVIDE EMERGENCY EXIT SIGNS AS DOCUMENTED.
GENERAL MAINTAINED AND NON-MAINTAINED LUMINAIRES: PROVIDE
LUMINAIRES AS DOCUMENTED.
OPERATING VOLTAGE: 230V AC.
VISUAL INDICATOR LIGHTS: PROVIDE A RED INDICATOR, READILY VISIBLE WHEN
THE LUMINAIRE IS IN ITS OPERATING LOCATION, WHICH INDICATES THAT THE
BATTERY IS BEING CHARGED.
BATTERIES
TYPE: PROVIDE HIGH TEMPERATURE NICKEL-CADMIUM BATTERIES CAPABLE OF
OPERATING EACH LAMP AT ITS RATED OUTPUT CONTINUOUSLY FOR AT LEAST 2
HOURS DURING COMMISSIONING TESTS AND 1.5 HOURS DURING SUBSEQUENT
TESTS.
BATTERY OPERATED OUTPUT: 70°C.
BATTERY LIFE: AT LEAST 3 YEARS WHEN OPERATING UNDER NORMAL
CONDITIONS AT AN AMBIENT TEMPERATURE OF BETWEEN 10°C AND 40°C AND
SUBJECT TO CHARGING AND DISCHARGING AT 6 MONTHLY INTERVALS.
MARKING: INDELIBLY MARK EACH BATTERY WITH ITS DATE OF MANUFACTURE.
POWER SUPPLY
GENERAL: PROVIDE AN UNSWITCHED ACTIVE SUPPLY TO EACH LUMINAIRE AND
EXIT SIGN, ORIGINATING FROM THE ADJACENT LIGHTING UNSWITCHED ACTIVE
CIRCUIT.
LABELLING
GENERAL: LABEL EACH LUMINAIRE WITH A UNIQUE IDENTIFYING NUMBER.
PROVIDE A LABEL WHICH IS PERMANENTLY FIXED, INDELIBLE AND READABLE AT
A DISTANCE OF 1 M.
EMERGENCY EVACUATION LIGHTING SCHEDULE: RECORD THE NUMBER AND
LUMINAIRE LOCATION IN AN EMERGENCY EVACUATION LIGHTING SCHEDULE
INCLUDED IN THE OPERATION AND MAINTENANCE MANUAL.
TESTS
GENERAL: CARRY OUT TESTS, INCLUDING OUT-OF-HOURS TESTS, TO
DEMONSTRATE THE EMERGENCY AND EVACUATION SYSTEM'S PERFORMANCE.
INCLUDE THE FOLLOWING:
TEST COMPONENTS FOR CORRECT FUNCTION AND OPERATION.
DEMONSTRATE ILLUMINATION PERFORMANCE ON SITE, TO AT LEAST THE
LEVEL STATED IN THE MANUFACTURER'S RECOMMENDATIONS FOR
PERFORMANCE FOR THAT DEVICE.
TEST OPERATION OF BATTERY DISCHARGE TEST AND CONTROL TEST
SWITCH FUNCTIONS, INCLUDING DISCHARGE AND RESTORATION.
DEMONSTRATE SYSTEM FUNCTIONS UNDER MAINS FAIL CONDITION.
DEMONSTRATE OPERATION OF THE BATTERY AND CHARGER INCLUDING A
FULL DISCHARGE/RECHARGE OVER THE DESIGNATED TIME.
MAINS SUPPLY
GENERAL: BEFORE COMMISSIONING, MAKE SURE MAINS SUPPLY HAS BEEN
CONTINUOUSLY CONNECTED FOR AT LEAST 24 HOURS.
2.7 LIGHTING CONTROL
GENERAL
REQUIREMENT: PROVIDE THE FOLLOWING AS DOCUMENTED;
LIGHTING SWITCHES.
AUTOMATIC CONTROL SYSTEMS.
INTERFACE BUILDING LIGHTING CONTROL VIA BMS INTO SITE SYSTEM.
MANUAL CONTROLS
GENERAL: PROVIDE MANUAL CONTROL OF LUMINAIRES INTO GROUPS, ZONES
AND TO INDIVIDUAL DEVICES, AS DOCUMENTED.
DIRECT CURRENT INTERFACE FOR PROXIMITY SENSORS AND AMPLIFIERS: TO
AS/NZS IEC 60947.5.6.
2.8 COMMUNICATION CABLING
GENERAL
GENERAL: PROVIDE A COMPLETE OPERATIONAL TENANCY
TELECOMMUNICATIONS PASSIVE CABLING SYSTEM, TESTED AND
COMMISSIONED IN CONFORMANCE WITH AS/NZS 11801, AS/ACIF S009 AND SAA
HB 29. PROVIDE ACCOMMODATION FOR TELECOMMUNICATIONS CABLING
INFRASTRUCTURE CONFORMING TO AS/NZS 3084 & CIOG REQUIREMENTS.
INCLUDE THE FOLLOWING:
NEW TELECOMMUNICATIONS OUTLETS TO SUIT NEW LAYOUT AND
DESCRIBED SYSTEMS
SYSTEM REQUIREMENTS
APPLICATION CLASS TO AS/NZS 11801 CLAUSE 6.3: E.
BALANCED SYSTEM TO AS/NZS 11801 CLAUSE 7 (DATA): CATEGORY 6.
BALANCED SYSTEM TO AS/NZS 11801 CLAUSE 7 (VOICE): CATEGORY 6.
CONFORMANCE: CERTIFY THE DESIGN AND INSTALLATION FOR CONFORMANCE
WITH AS/NZS 11801 CLAUSE 4.
TESTING OF CABLES TO 'PERMANENT LINK' TO REQUIREMENTS OF AS/NZS 11801
SYSTEM WARRANTY: WARRANT THE SPECIFIED COMMUNICATIONS EQUIPMENT
AND CABLING CHANNEL PERFORMANCE FOR A MINIMUM OF 15 YEARS.
MODULAR CONNECTOR PATCH PANELS
TERMINATIONS: TERMINATE FIXED WIRING DIRECTLY TO THE MODULAR
CONNECTOR.
PATCH CORDS & FLY LEADS: BY IT VENDOR.
EQUIPMENT RACKS
TO BE PROVIDED AND INSTALLED BY US NAVFAC.
CABLE SEPARATION
LOW VOLTAGE CABLES: SEPARATE TELECOMMUNICATIONS CABLES NOT
ENCLOSED IN CONDUITS OR DUCTS FROM LOW VOLTAGE SERVICES BY AT
LEAST 150mm.
ELECTROMAGNETIC INTERFERENCE (EMI): PROVIDE CLEARANCE TO MINIMISE
THE EFFECT OF EMI WHERE COMMUNICATIONS CABLES ARE INSTALLED
PARALLEL AND ADJACENT TO POWER CABLES CARRYING LOADS IN EXCESS OF
200 A.
INSTALLATION
COMMUNICATION INSTALLATION TO COMPLY WITH THE FOLLOWING:
DEFENCE COMMUNICATIONS CABLING STANDARD
DEFENCE COMMUNICATIONS ROOM STANDARD
DEFENCE SERVER ROOM STANDARD
DEFENCE SECURITY PRINCIPLES FRAMEWORK (DSPF)
INFORMATION SECURITY MANUAL (ISM)
CROSSOVER: INSTALL CABLES NEATLY AND WITHOUT CROSSOVERS BETWEEN
CABLES.
LOOM SIZE: LOOM CABLES INTO GROUPS NOT EXCEEDING 50 CABLES, AND HOLD
LOOMS IN PLACE USING REUSABLE VELCRO AT LEAST 20 mm WIDE. DO NOT
EXERT COMPRESSIVE FORCE ON THE CABLES WHEN INSTALLING CABLE
STRAPS. PVC CABLE TIES SHALL NOT BE USED.
TELECOMMUNICATIONS OUTLETS
OUTLETS: PROVIDE RJ45 8 WAY MODULAR JACKS EXCEPT WHERE DOCUMENTED
OTHERWISE.
LABELLING
LABEL BOTH ENDS OF ALL CABLES DURING INSTALLATION.
COMMUNICATION CONDUIT
MINIMUM 2x100mm CONDUIT FOR ANY AREA OF INSTALLATION, PROVIDE MARKER
TAPE ABOVE CONDUIT (PER DCCS REQUIREMENTS). PROVIDE DRAW CHORDS AN
EVERY CONDUIT WITH EYE-BOLT ANCHOR, PER DCCS.
2.9 CABLE SUPPORTS AND DUCT SYSTEM
RESPONSIBILITIES
GENERAL
PROVIDE CABLE SUPPORT, TRUNKING AND DUCT SYSTEMS, AS DOCUMENTED.
PROVIDE FIRE RATED CABLE SUPPORTS FOR LIFE SAFETY SYSTEMS. PROVIDE
TEST CERTIFICATES TO AS/NZS 3013.
CONDUITS
STANDARDS: AS/NZS 2053.1
TYPE: RIGID.
SIZES
CONDUITS: 20 mm.
UNDERGROUND: 25 mm.
CONDUITS FOR TELECOMMUNICATIONS: 25 mm.
FIXINGS
SURFACE MOUNTED: DOUBLE SIDED FIXED.
IN CONCRETE SLABS: TIE TO STRUCTURAL STEEL.
COLOUR
CONDUITS GENERALLY: LIGHT ORANGE.
TELECOMMUNICATIONS SYSTEMS CONDUITS: WHITE.
NON-METALLIC CONDUITS AND FITTINGS
GENERAL
STANDARDS: NON-METALLIC CONDUITS AND FITTINGS: AS/NZS 2053.2, AS/NZS
2053.3, AS/NZS 2053.4, AS/NZS 2053.5 OR AS/NZS 2053.6.
SOLAR RADIATION PROTECTION: REQUIRED FOR CONDUITS AND FITTINGS
EXPOSED TO SUNLIGHT.
FLEXIBLE CONDUIT
GENERAL: PROVIDE FLEXIBLE CONDUIT TO CONNECT WITH EQUIPMENT AND
PLANT SUBJECTED TO VIBRATION. IF REQUIRED, PROVIDE FOR ADJUSTMENT OR
EASE OF MAINTENANCE. PROVIDE THE MINIMUM POSSIBLE LENGTH.
ASSOCIATED FITTINGS
TYPE: PROVIDE ASSOCIATED FITTINGS OF THE SAME TYPE AND MATERIAL AS
THE CONDUIT.
WALL BOXES ON UPVC CONDUITS: PROVIDE PREFABRICATED EARTHED METAL
BOXES, FOR SPECIAL SIZE WALL BOXES NOT AVAILABLE IN UPVC.
INSPECTION FITTINGS
GENERAL: PROVIDE INSPECTION-TYPE FITTINGS ONLY IN ACCESSIBLE
LOCATIONS AND WHERE EXPOSED TO VIEW.
JOINTS
TYPE: CEMENTED OR SNAP-ON JOINTS.
CABLE PITS
GENERAL
CABLE DRAW-IN PITS: PROVIDE CABLE DRAW-IN PITS AS DOCUMENTED. SIZES
GIVEN ARE INTERNAL DIMENSIONS.
COMMUNICATION PITS PER DCCS SIZE REQUIREMENTS.
PROPRIETARY CABLE PITS
PITS 1200 X 1200 mm: PROVIDE PROPRIETARY CONCRETE OR POLYMER
MOULDED PITS.
IN SITU CONSTRUCTION
PITS > 1200 X 1200 mm: PROVIDE EITHER:
PROPRIETARY CABLE PITS.
CONSTRUCT WALLS AND BOTTOMS FROM 75 mm THICK REINFORCED
CONCRETE. INCORPORATE A WATERPROOFING AGENT IN THE RENDER OR
CONCRETE.
PIT COVERS
GENERAL: PROVIDE PIT COVERS TO SUIT EXTERNAL LOADS. FIT FLUSH WITH THE
TOP OF THE PIT.
STANDARD: TO AS 3996.
WEIGHT: < 40 KG FOR ANY SECTION OF THE COVER.
LIFTING HANDLES: PROVIDE A LIFTING HANDLE FOR EACH SIZE OF COVER
SECTION.
DRAINAGE
GENERAL: PROVIDE DRAINAGE FROM THE BOTTOM OF CABLE PITS, EITHER TO
ABSORPTION TRENCHES FILLED WITH RUBBLE OR TO THE STORMWATER
DRAINAGE SYSTEM.
ABSORPTION TRENCHES: MINIMUM SIZE 300 x 300 x 2000 mm.
EXECUTION CONDUIT SYSTEMS - INSTALLATION INSPECTION FITTINGS
LOCATION: LOCATE IN ACCESSIBLE POSITIONS.
DRAW CORDS
GENERAL: PROVIDE 5 mm2 POLYPROPYLENE DRAW CORDS IN CONDUITS NOT IN
USE. ENSURE DRAW CORDS WITHIN COMMUNICATION CONDUITS ARE
ANCHORED WITH EYE-BOLT PER DCCS STANDARDS.
DRAW-IN BOXES
GENERAL: FOR CONDUITS IN ACCESSIBLE LOCATIONS PROVIDE DRAW-IN BOXES
AS FOLLOWS:
IN STRAIGHT RUNS AT > 30m: SPACING 30m.
AT CHANGES OF LEVEL OR DIRECTION.
UNDERGROUND DRAW-IN BOXES: PROVIDE GASKETED COVERS AND SEAL
AGAINST MOISTURE. INSTALL IN ACCESSIBLE PITS.
EXPANSION
GENERAL: ALLOW FOR THERMAL EXPANSION/CONTRACTION OF CONDUITS AND
FITTINGS DUE TO CHANGES IN AMBIENT TEMPERATURE CONDITIONS. PROVIDE
EXPANSION COUPLINGS AS REQUIRED.
RIGID CONDUITS
GENERAL: PROVIDE STRAIGHT LONG RUNS, SMOOTH AND FREE FROM RAGS,
BURRS AND SHARP EDGES. SET CONDUITS TO MINIMISE THE NUMBER OF
FITTINGS.
ROUTES
SET OUT: IF EXPOSED TO VIEW, INSTALL CONDUITS IN PARALLEL RUNS WITH
RIGHT ANGLE CHANGES OF DIRECTION.
BENDS: INSTALL CONDUITS WITH NO MORE THAN 2 RIGHT ANGLED BENDS PER
CABLE DRAW-IN RUN.
CONCEALED CONDUITS: RUN CONDUITS CONCEALED IN WALL CHASES,
EMBEDDED IN FLOOR SLABS OR INSTALLED IN INACCESSIBLE LOCATIONS
DIRECTLY BETWEEN POINTS OF TERMINATION, MINIMISING THE NUMBER OF
SETS. DO NOT PROVIDE INSPECTION FITTINGS. USE LARGE RADIUS BENDS OR
ELBOWS.
CONDUITS IN CONCRETE SLABS
ROUTE: DO NOT RUN IN CONCRETE TOPPINGS. DO NOT RUN WITHIN
PRETENSIONING CABLE ZONES. CROSS PRETENSIONING CABLE ZONES AT
RIGHT ANGLES. ROUTE TO AVOID CROSSOVERS AND MINIMISE THE NUMBER OF
CONDUITS IN ANY LOCATION.
PARALLEL CONDUIT SPACING: 50 mm APART.
CONDUITS IN MECHANICAL PLANT ROOM SLABS: AVOID INSTALLATION OF
CONDUITS IN PLANT ROOM SLABS (BOILER ROOMS, MECHANICAL PLANT ROOMS
AND TANK ROOMS) IF CONDUITS AND CABLES ARE LIKELY TO EXPERIENCE HIGH
TEMPERATURES, BE SUBJECT TO CORE HOLE DRILLING, DRILLING OF LARGE
ANCHOR BOLT POINTS OR WHERE EXACT PLANT LOCATIONS ARE UNKNOWN AT
TIME SLAB IS POURED.
MINIMUM COVER: THE GREATER OF THE CONDUIT DIAMETER AND 20 mm.
CONSTRUCTION JOINTS: PROVIDE SLEEVING OVER CONDUIT TO ALLOW
MOVEMENT OF THE CONDUIT ACROSS THE JOINT DUE TO ANY SLAB
MOVEMENT.
FIXING: FIX DIRECTLY TO THE TOP OF THE BOTTOM LAYER OF REINFORCING.
CONDUITS IN HOLLOW-BLOCK FLOORS
LOCATION: LOCATE CONDUITS IN THE CORE-FILLED SECTIONS OF PRECAST
HOLLOW-BLOCK TYPE FLOORS.
CONDUITS IN COLUMNS
NUMBER AND SIZE OF CONDUITS IN COLUMNS: AS DETERMINED BY THE
STRUCTURAL ENGINEER.
BENDS
ENTER COLUMNS WITH RADIUS SWEEP BENDS GREATER THAN OR
EQUAL TO 150 mm. DO NOT USE ELBOWS.
CHASING
DO NOT CHASE COLUMNS.CABLES IN TRENCHES - INSTALLATION
SAND BED AND SURROUND
GENERAL: CONFORM TO THE SERVICE TRENCHING WORKSECTION.
SAND BED AND SURROUNDS: PROVIDE AT LEAST 150 mm CLEAN SHARP SAND
AROUND CABLES AND CONDUITS INSTALLED UNDERGROUND.
SEALING DUCTS AND CONDUITS
GENERAL: SEAL BURIED ENTRIES TO DUCTS AND CONDUITS WITH WATERPROOF
SEALS AS FOLLOWS:
SPARE DUCTS AND CONDUITS: IMMEDIATELY AFTER INSTALLATION.
OTHER DUCTS AND CONDUITS: AFTER CABLE INSTALLATION.
ALL SURFACES ARE TO BE REINSTATED TO A QUALITY EQUAL TO OR BETTER
THAN EXISTING SURFACE QUALITY.
AI
TA
PE
RO
AD
C
C C C C C C C C C C C C C C
C
C
C C C C C C C C C C C C C C C
C
C
C
C C
C
C2
HM
HM
C C
C
C C C C C
C C
C
C C
C C
C C
C C
C C
C
C C
C C
C C
C
C C
C C
C C
C C
C
C
E C
C
C
C
C C
E
E
E
E
E E
E E
E
E
E
E
E
E
E
E
E
C C
C C
E E
E2
E E2
E
E
E
E
E2
E
E
E
E
E
E2
E2
E
E
E
E E
E E
E E
E
EE
E C
C
C C
C C
C C
C C
C C
C C
C C
C C
C C
C
C
C
C
E
E2E2
E2
E2
E E
C C
C C
C
CE
E
E
C C
C C
C
CE
E C
C C
AI
TA
PE
ROAD
TARAKAN
R O
AD
FU
EL L
IN
E
FU
EL P
IP
E
GIV
No s erv ice s
Brok en
Li d
Bott om
M H 12
9.3
E(HV)
E(HV)
E(H V)
E(H V)
E(H V)
E(H V)
S
S
S
S
W
W
S
Red un da nt?
Red un da nt?
S
S
S
S
IL
.8
S S
S S
Ø
E(LV) E(LV) E(LV) E(LV) E(LV) E(LV)
T
T
T
T
T
T
CS02
CS03
CS04
E-101
SQUADRON OPERATIONS BUILDING
E16929No.
LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV
AGLAGLAGLAGLAGLAGLAGLAGL
AGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLL
AGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLGL
AGLAGLAGLAGLAGLAGLAGLAGL
AG
L
AG
L
AG
L
AG
L
AGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGL
AG
L
AG
L
AG
L
AG
L
AG
L
AG
L
AG
L
AG
L
AGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGL
AG
L
AG
L
AG
L
AG
L
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C C
C C
C C
C C
C C
C C
C C
C C
C C
C C
C C
C C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C C
C C
C C
C C
C C
C C
C C
C C
C C
C C
C C
C C
C C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C C
C C
C C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
D D D D D D D
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
CCCCCCCCC
DDDDD
D D D D D D D
E
V)
E(HV) E(HV)
E(HV)
E(HV) E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(H V)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(H V)
E(H V)
E(H V)
E(H V)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(H V)
E(H V)
E(H V)
E(H V)
E(H V)
E(H V)
E(H V)
E(H V)
E(H V)
E(H V)
E(H V)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E( H
V) E(
H V)
E( H
V) E(
H V)
E( H
V) E(
H V)
E( H
V) E(
H V)
E( H
V) E(
H V)
E( H
V) E(
H V)
E( H
V) E(
H V)
E( H
V)
E(H V)
E(HV)
E(HV)
E(H V)
E(H V)
E(H V)
E(H V)
E(H V)
E(H V)
E(H V)
E(H V)
E(H V)
E(H V)
E(H V)
E(H V)
E(H V)
E(H V)
E(H V)
E(H V)
E(H V)
E(H V)
E(H V)
E(H V)
E(H V)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(HV)
E(
HV
E(
HV
E(
HV
E(H V)
E(H V)
FI
FI
FI
FI
FU
FU
FU
FU
FU
FU
FU
FU
FU
FU
FU
FU
FU
FU
FU
FU
FU
FU
FU
FU
FU
FU
FU
FU
FU
FU
FU
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S
LV
E(
LV
E(
LV
E(
LV
E(
LV
E(
LV
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E E E
E E
E E
E
W W
W W
W W
W W
W W
W W
W W
W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
(H V) V
C
H V
E(H
FU
E
E
E
E
E E
E E
E E
E E
E E
E
E
E
C
C C
C C
C C
C C
C
C
C
C
E
C
C C
C C
C C
C C
C C
C C
C C
C C
C C
C C
C C
C C
C
CE
E
E
E
C C
C C
C C
C
CE
E C
C C
E-102
E16929No.
GF-002
GF-003
GF-004
GF-005
GF-008 GF-011
GF-009
GF-010
GF-012
GF-013
GF-006
GF-007
GF-015
GF-016
GF-017
GF-018
GF-019GF-020
GF-021GF-026
GF-022
GF-024
GF-025
GF-027
GF-028
GF-029 GF-030
GF-031
GF-032
GF-023
SE
C
AB
E(
LV
E(
LV
E(
LV
E(
LV
E(
LV
E(
LV
E(
LV
AB
MSB
EWH
3N,63A
ACCU
1N,10A
ACCU
3N,32A
ACCU-5
1N,32A
ACCU
1N,32A
HWU
1N,10A
1N,32A
1N,32A
SEC
1N,10A
1N,32A
MDB
AB
EF
1N,10A
EF
1N,10A
BP
1N,10ABP
1N,10A
ACCU
3N,40A
WPWP
WP
IBT
BUSBAR
(NOTE 12)
EF
1N,10A
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
DB-TEF
E(
LV
E(
LV
E(
LV
E(
LV
E(
LV
E(
LV
E(
LV
AD
TX
ACCU-4
1N,32A
WWP
1N,10A
E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV)
FRMW
MSSB-P2
MSSB-P1
MSSB-P3
MSSB-P12
MDB-P8
MDB-P9
MDB-P10
MSSB-P7
DB-TEF-P3
DB-TEF-P2
DB-TEF-P1
MSB-SEC
MSSB-P10
MSSB-P11
MDB-P1
MDB-P2
MDB-P3
MDB-P4
MDB-P5
MDB-P6
MDB-P11
MDB-P12
MDB-P13
MDB-P14
MDB-P15
MDB-P16
MDB-P17
MSSB-P9
MSSB-P6
MSSB-P5
MSSB-P4
MSSB-P13
MSSB-P14
DB-TEF-P4
MDB-P7
MSSB-P17
MDB-P18
DB-TEF-P5
1N,32A
1N,32A
1N,32A
DB-TEF-P7
DB-TEF-P6
DB-TEF-P8
1N,32A
MDB-P19
MDB-PX
NOTE 19
24RU CABINET
FOR DESN
E-111
E16929No.
NOTES
1. DRAWING TO BE READ IN CONJUNCTION WITH ARCHITECTURAL AND OTHER SERVICES DRAWINGS.
2. FINAL LOCATIONS OF ELECTRICAL EQUIPMENT, POWER SUPPLIES AND ISOLATORS SHALL BE DETERMINED ON SITE BY
ELECTRICAL CONTRACTOR IN CO-ORDINATION WITH THE RESPECTIVE TRADE TO SUIT EQUIPMENT AND INSTALLATION CONDITIONS.
3. THE CONTRACTOR SHALL LIAISE WITH THE MECHANICAL, HYDRAULIC, FIRE CONTRACTORS AND THE ARCHITECT TO CONFIRM FINAL LOCATION OF
4. ALL CABLING SYSTEMS SHALL BE INSTALLED ON TENSION WIRE/TRAY, IN FALSE CEILINGS, IN SUITABLE DUCT UNDER BENCHES.
5. ALL POWER OUTLETS SHALL BE LABELLED TO INDICATE TO WHICH DISTRIBUTION BOARD AND CIRCUIT IT IS CONNECTED.
6. POWER CABLE TRAY SHALL BE 600mm. EARTH METALLIC PARTS OF THE CABLE TRAY TO DB EARTH BAR.
7. FLOOR BOX TO BE SUPPLIED VIA 25mm CONDUIT FROM WALL.
8. REFER TO MECHANICAL SPECIFICATION FOR FAN COIL UNITS & POWER CONNECTIONS.
9. SUPPLY POWER TO VAV BOXES. CABLE SHALL BE NO LESS THEN 4mm² PVC.
10. GPOS IN TOLIETS ROOMS TO BE INSTALLED AT COUNTER HEIGHT.
11. PRIMARY BUS BAR TO BE INSTALLED WITHIN DB-TEF. ALL TELLECOMMUNICATIONS DEVICES TO BE CONNECT TO THE THE BONDING BUS BAR.
12. OUTLET SHALL BE ABOVE DOOR FOR POTENTIAL ESS.
13. ALLOW FOR CONDUIT, CABLE AND CONNECTION OF LIGHTNING PROTECTION MASS EARTH INTO MSB MEN SYSTEM.
14. PRESTIGE TYPE GPO SWITCHES TO BE USED FOR THE PWD TOLIET, INSTALLED AT 800 AFFL.
15. SUPPLY POWER TO MECHANICAL CONTROL PANELS FROM MECHANICAL SERVICES SWITCH BOAR.
16. PROVIDE 4x25mm CONDUITS TO FUTURE SECURITY CONTROL PANEL LOCATION. MAKE SUFFICIENT SPATIAL ALLOWANCE FOR TYPE 1A PANEL
TO BE INSTALLED AND COMMERCIAL GRADE ACCESS CONTROL PANEL. CAP OFF CONDUITS.
17. PROVIDE 25mm CONDUIT AND JUNCTION BOXES TO TOP OF DOOR TO ALLOW FOR FUTURE DOOR REED SWITCH. CAP OFF CONDUIT. PROVIDE DRAW ROPE.
18. PROVIDE 2x25mm CONDUIT AND JUNCTION BOXES TO TOP OF DOOR TO ALLOW FOR FUTURE MAGLOCK AND DOOR POSITION SWITCH.
19. POWER CONNECTION FOR HOT WATER RETURN SYSTEM . COORDINATE LOCATION WITH MECHANICAL/HYDRAULIC DESIGN AND INSTALLATION.
20. ALL PENETRATIONS MUST BE APPROPRIATELY SEALED TO MAINTAIN FIRE, ACOUSTIC AND SECURITY RATINGS OF ROOMS.
GF-004
GF-005
GF-008 GF-011
GF-009
GF-010
GF-012
GF-013
GF-006
GF-007
GF-015
GF-016
GF-017
GF-018
GF-019GF-020
GF-021GF-026
GF-022
GF-024
GF-025
GF-027
GF-028
GF-029 GF-030
GF-031
GF-032
GF-023
MSB
MDB
2 2 2 2
CT1CT1CT1CT1CT1CT1CT1CT1CT1CT1CT1CT1CT1CT1CT1CT1CT1CT1CT1CT1CT1CT1
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
1 CT2CT2CT2CT2CT2CT2CT2CT2CT2CT2CT2CT2CT2CT2CT2CT2CT2CT2CT2CT2CT2CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT2CT2CT2CT2CT2CT2CT2CT2
CT3CT3CT3CT3CT3CT3CT3CT3
CT
CT
CT
CT
CT3CT3CT3CT3CT3CT3
CT2CT2CT2CT2CT2
CT
CT
CT
CT
CT
CT
CT3CT3CT3CT3CT3CT3CT3CT3CT3CT3
CT2CT2CT2CT2CT2CT2CT2CT2CT2CT2 CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT3
CT2
CT3
CT2
CT3
CT2
CT3
CT2
CT3
CT2
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
E(
LV
E(
LV
E(
LV
E(
LV
E(
LV
E(
LV
E(
LV
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
E(
LV
E(
LV
E(
LV
E(
LV
E(
LV
E(
LV
E(
LV
DB-TEF
CT
CT
CT3CT3CT3CT3
CT2 CT2 CT2CT2CT2
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
2 2
(NOTE 14)
CT4CT4CT4
CT4CT4CT4CT4CT4CT4CT4CT4CT4CT4CT4CT4CT4CT4CT4CT4CT4
CT4CT4CT4CT4CT4CT4CT4CT4CT4CT4CT4CT4
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
CT
S
S
S
S
S S
S S
S S
S S
S
S S
S S
S S
S S
S S
S
S S
S S S S S
SS
S S
S S
S S
S S
S S
S S
S S
S
S
(NOTE 2)(NOTE 2)
(NOTE 2)(NOTE 2)
(NOTE 1)
(NOTE 1)
(NOTE 1)
(NOTE 1)
(NOTE 1)
(NOTE 1)
(NOTE 1)
(NOTE 1).
(NOTE 1) (NOTE 1)
(NOTE 1)
(NOTE 3)
(NOTE 1)
24RU CABINET
FOR DESN
E-121
E16929No.
NOTES
1. 25mm COMMUNICATIONS CONDUIT CONCEALED WITHIN THE WALL CAVITY FROM CABLE TRAY IN CEILING TO TERMINATE AT 150mm SQUARE JUNCTION BOX AT 1000mm ABOVE FGL. ENSURE
JUNCTION BOX JOINT IS TIGHT AND SECURE WITHIN WALL AND DOES NOT PROTRUDE BEYOND FINISHED SURFACE. PROVIDE FLAT BLANK COVER PLATE WITH TAMPER RESISTANT SCREWS.
2. 25mm COMMUNICATIONS CONDUIT FROM CEILING MOUNTED CABLE TRAY TO CEILING POINTS AS SHOWN ON DRAWING.
3. 2 X 50mm COMMUNICATIONS CONDUIT CONCEALED WITHIN THE WALL CAVITY FROM CEILING MOUNTED CABLE TRAY TO 1000mm ABOVE FG.
4. SECURE AND UNSECURED COMMUNICATIONS CABLE TRAY SHALL BE AT LEAST 300mm APART. SPACE AND SIZE OF CABLE TRAYS ON DRAWING INDICATIVE ONLY.
5. CABLE ACCESS BETWEEN SECURE AND UNSECURED ZONES SHALL BE VIA SEALED CONDUIT RACEWAY THROUGH THE SECURE WALL.
6. PAIRS OF DOUBLE DATA OUTLETS SHALL BE SPLIT BETWEEN USAF UNSECURED AND SECURED WITHIN THE SECURE ZONE. REFER TO BLOCK DIAGRAM ON E-603.
7. PAIRS OF DOUBLE DATA OUTLETS SHALL BE SPLIT BETWEEN USAF UNSECURED AND AUS DPN WITHIN THE UNSECURED ZONE. REFER TO BLOCK DIAGRAM ON E-603.
8. CABLE TRAYS SHALL BE 300mm ENSURE CABLE TRAYS HAVE 50% SPARE CAPACITY. EARTH METALLIC PARTS OF CABLE TRAY TO DB EARTH BAR.
9. CONTRACTOR SHALL FOLLOW THE COMMUNICATIONS CABLING REQUIREMENTS APPLICABLE SECURITY STANDARD FOR AUSTRALIAN DEFENCE (COLOURS PER AUS DEFENCE REQUIREMENTS).
10. AUSTRALIAN RACK SHALL BE A CLASS - C CABINET.
11. COMMUNICATION CABLING WITHIN BUILDING SHALL BE INSTALLED ON THE DESCRIBED CABLE TRAY OR WITHIN CONDUIT
12. FLOOR BOXES SHALL BE SUITABLE FOR ZONE 2 SECURITY. BUT UPGRADEABLE TO ZONE 4 IN THE FUTURE.
13. OUTLET LABELS SHALL BE PER DCCS STANDARDS.
14. ONE QUAD DATA OUTLET SHALL BE CONNECTED TO USAF UNSECURED AND SECURED RACKS.
15. CIOG DEFENCE SHALL HAVE ACCESS TO COMMUNICATIONS ROOM. COORDINATE ROOM ACCESS WITH CIOG.
16. CONTINUOUS CONDUITS SHALL RUN FROM POWER AND COMMUNICATION OUTLETS ALL THE WAY TO CABLE TRAY.
17. 24RU WALL MOUNTED CABINET FOR BUILDING DESN, BMS AND FIP EQUIPMENT. CABINET SHALL BE CONNECTED TO WIDER SITE. EQUIVALENT TO STARTECH RK630WALVS.
18. PROVIDE 100mm RACEWAY CHASE PENETRATION THROUGH WALL FOR COMMUNICATIONS CABLES. CHASE SHALL EXTENDED BEYOND WALL SURFACE MINIMUM 300mm ON EACH SIDE.
GF-004
GF-005
GF-008 GF-011
GF-009
GF-010
GF-012
GF-013
GF-006
GF-007
GF-015
GF-016
GF-017
GF-018
GF-019GF-020
GF-021GF-026
GF-022
GF-024
GF-025
GF-027
GF-028
GF-029 GF-030
GF-031
GF-032
GF-023
FDCIE TO BE RECESSEDFFFFFFFFFDDDDDDDDDDDDCCCCCCCCCCCCIIIEEEEEEEEEEE TTTTTTTTTTTOOOOOOOOOOOOOO BBBBBBBBBBBEEEEEEEEEE RRRRRRRRRRRREEEEEEEEEECCCCCCCCCCCCCEEEEEEEEEEESSSSSSSSSSSSSSSSSSSSSSSSEEEEEEEEEEEDDDDDDDDDDDD
L1 L1 L1L1 L1 L1L1L1
L1L
L1
L1
L1L1L1L1
L11
L1L1
L1 L1
L11
L1
L1
L1L
L1L1
L1
L1 L1 L1 L1 L1 L1L1
L1
L1LL1
L1 L1
L1 L1
L1
L1 L1
L1L1
L1 L1
L1
L1
L1
L1 L1
L1L1
L1 L1
L1LL
L1
L1 L1
L1L1 L1
L1 L1
L1 L1L1
L1
L1 L1
L1
L1
L1 L1
L1
L1
L1L1
L1
L1
L1 L1
L1
L1 L1
L1
L1 L1L1
L1
L1L1
L1
L1L1
L1 L1 L1
L1LL1L1L1
L1 L1
L2 L2L2 L2
L2
L2
L2L2
L2
W1
W1W1W1
W1
W1
W1
W1
W1
W1 W1 W1 W1 W1 W1
W1
W1
W1
W1111111WWWWWWWWWWWWWWWWWW
W1
W1
W1
D100 D1D1D11D1
D1 D1 D1DDDDDDDDD D1D11111
D1D1 D1
D1D D1DD1
D1D1 D1D1D1D1
D1D D1
D1
L1
D1 D1
D1D1D1
DS
L1
D1 D1 D1 D1 D1
DDGG
D1D1
L2
W1
L3L3L3L3L3LL3
MDB-L1
MDB-L2
MDB-L3
MDB-L4
MDB-L5
MDB-L6
MDB-L7
MDB-L8
MDB-L9
MDB-L10
L2
L2L2L2
L2 L2 L2
L2
L2
E-131
E16929No.
NOTES
1. PROVIDE ALL LUMINARIES COMPLETE WITH LAMPS AND ACCESSORIES AS SPECIFIED.
2. EMERGENCY EVACUATION LIGHTING SYSTEM TO MEET THE REQUIREMENTS OF THE BCA. TEST AND COMMISSION IN CONFORMANCE WITH AS/NZS 2293.
3. COORDINATE HEIGHT OF SWITCHES WITH ARCHITECTURAL EQUIPMENT SCHEDULES.
4. COORDINATE LIGHTING LAYOUT WITH CEILING GRID. REFER TO ARCHITECTURE SPECIFICATIONS AND DRAWINGS.
5. REAR BLOCKING BEHIND CLADDING IS REQUIRED WHERE EXTERNAL LIGHTING SHALL BE INSTALLED. REFER TO ARCHITECTURAL DRAWINGS FOR EXTERNAL LIGHT FITTING HEIGHTS. NOMINALLY
2500AFFL.
E E
E
E
E
EEE
P1
P2
P1
P1P1
P1 P1
W W
W
W W
W
WW
S
S S
HM
HM
C C
C
C C C C C
C C
C C
C C
C C
C C
C C
C C
C C
C C
C C
C
E C
C
C C
E
C C
C
E
E
E2
E
E
E
E E
E E
E E
E
EE
E2E2
E2
E2
E-132
SQUADRON OPERATIONS BUILDING
E16929No.
GF-004
GF-005
GF-008 GF-011
GF-009
GF-010
GF-012
GF-013
GF-006
GF-007
GF-015
GF-016
GF-017
GF-018
GF-019GF-020
GF-021GF-026
GF-022
GF-024
GF-025
GF-027
GF-028
GF-029 GF-030
GF-031
GF-032
GF-023
GF-002
GF-003
GF-004
GF-005
GF-008 GF-011
GF-009
GF-010
GF-012
GF-013
GF-006
GF-007
GF-015
GF-016
GF-017
GF-018
GF-019GF-020
GF-021GF-026
GF-022
GF-024
GF-025
GF-027
GF-028
GF-029 GF-030
GF-031
GF-032
GF-023
320 LUX
320 LUX
320 LUX
320 LUX
320 LUX
320 LUX
320 LUX
320 LUX
400 LUX
400 LUX
240 LUX
240 LUX
240 LUX
240 LUX
240 LUX
240 LUX240 LUX
240 LUX
240 LUX
240 LUX
240 LUX
240 LUX
240 LUX
240 LUX
240 LUX
160 LUX
160 LUX
160 LUX
160 LUX
160 LUX
160 LUX
160 LUX
160 LUX
160 LUX
320 LUX
320 LUX
320 LUX
240 LUX
320 LUX
320 LUX
240 LUX
E-141
E16929No.
32 LUX
32 LUX
32 LUX
32 LUX
32 LUX
32 LUX
32 LUX
32 LUX
7 LUX
7 LUX
7 LUX
7 LUX
7 LUX
7 LUX
7 LUX
7 LUX
7 LUX
7 LUX
7 LUX
7 LUX
1.5 LUX1.5 LUX
7 LUX
1.5 LUX
1.5 LUX
1.5 LUX
7 LUX
1.5 LUX
7 LUX
7 LUX
7 LUX
7 LUX
E-142
SQUADRON OPERATIONS BUILDING
E16929No.
E-151
E16929No.
1. LIGHTNING PROTECTION SHALL BE INSTALLED PER AS/NZS 1768 AND AS 4262
2. ALL CONDUCTORS AND EARTH ELECTRODES TO BE SIZED AND SPACED PER AS 1768
3. EARTH RING SHALL HAVE A NOMINAL DEPTH OF 400mm AND A NOMINAL OFFSET FROM THE BUILDING OF 400mm
4. EARTHING RESISTANCE SHOULD NOT EXCEED 10ohms PER AS 1768.
5. TEST LINKS SHALL BE PROVIDED FOR EACH INDIVIDUAL PARALLEL PATH OF THE LIGHTNING CONDUCTOR SYSTEM. TEST LINKS ARE TO BE SECURED IN
THE CLOSED POSITION AND ARRANGE SO WHEN OPENED IT DOES NOT INTERFERE WITH THE REST OF THE SYSTEM PER AS 1768.
6. EARTHING RING SHALL BE CONNECTED INTO THE MSB M.E.N BUS BAR.
7. DOWN CONDUCTORS TO BE EXPOSED ON FACE OF BUILDING. AIR TERMINAL CONDUCTOR SHALL CONNECT TO ELECTRODE IN EARTH PT VS EARTH
RING.
8. AIR TERMINALS SHALL NOT EXCEED 600mm FROM OUTSIDE EDGE OF ROOF
EXIT FLAPDESK CUTOUT
& LID
DESK FLY LEADS TO EQUIPMENT
PLATE
POWER CUTTERS
GROMMETS
FLOOR WEIGHT
SWITCHED SOCKET OUTLET
OR STARTER SOCKET
CONDUITS CAST IN SLAB SEPARATE
FOR POWER, COMMS
HOUSING
PHYSICAL BARRIERS FOR AV, DATA
& POWER SECTION RESPECTIVELY
CONDUITS CAST IN SLAB SEPARATE
FOR POWER, COMMS
SLAB
OUTLETS
PLATE
RECESSED IN LID
FOR CARPET
FLOOR
WEIGHT
DATA, AV & SECURITY
EQUIPMENT
BARRIER
HOUSING
CORNER VIEW
FLAT VIEW
FINISHED GRADE
CONCRETE LID
EARTH ROD PIT (NOTE 6)
NATIVE SOIL OR
COMPACTED BACKFILL
CONCRETE
DUCTILE IRON PIPE
MIN. INSIDE
BRICK LEVELING COURSE
PRIMARY LIGHTNING PROTECTION
CONDUCTOR RUN ALONG ROOF EDGE.
POINT AND POINT BASE (INCLUDING
CABLE HOLD DOWN CLAMPS)
SECURED TO ROOF PANEL WITH
SILICON ADHESIVE/SEALANT RATED
FOR HIGH TEMPERATURE, UV/OZONE
RESISTANCE, AND NO CORROSIVE.
PRIMARY LIGHTNING PROTECTION
EQUALIZATION CONDUCTOR.
ROOF SYSTEM.
(NOTE 5).
PROVIDE ORANGE ORNAMENTAL
BALL ON ALL TERMINALS MARKED "A".
BI-DIRECTION BOND 35mm² INSULTED
STRANDED COPPER CONDUCTOR
CABLE SUPPORT
SEE DETAIL
COMPRESSION "C-TAP"
(TYPICAL)
BI-DIRECTION BOND 35mm² INSULTED
STRANDED COPPER CONDUCTOR
BI-DIRECTION BOND 35mm²
INSULTED STRANDED
COPPER CONDUCTOR
200 x 200
900 x 900 SQUARE
GROUND CONDUCTOR 12mm DIAMETER COPPER CLAD STEEL, 1500mm LONG
MINIMUM COVER
TO CONDUITS
MARKER TAPES
ELECTRICAL/COMMS CONDUITS AS NOTED
STONE FREE SAND FILL. MINIMUM
50mm COVER ABOVE AND BELOW60
BACKFILL
MI
N
0m m
EARTH RING SOLID TIN BARE
CONDUCTOR Cu 70mm²
CABLING PIT
INCOMING CONDUITS
MARKING TAPE
FLOOR LEVEL
CABLE PIT DETAIL ADJACENT TO THE BUILDING WITH CONDUITS RUNNING UNDER FOOTINGS
CONCRETE REINFORCING
COLLAR TO ALL PITS
ENSURE ALL CONDUIT ENTRIES ARE MIN. 50mm
INSIDE PIT & ARE FREE OF BURRS & SHARP EDGES.
CONDUIT SHALL ENTER 300mm ABOVE BASE OF PIT.
CONDUIT TO FINISH 100mm
AFL WITH APPROVED SEALANT
(VERMIN PROOF).
APPROVED TERMITE BARRIER
SYSTEMPIPE COLLAR
PER AS 3660.
SCEC APPROVED PIT AND
PIT LED. VERMIN AND
SNAKE PROOF
REFER TO STRUCTURAL SET
FOR EXTERNAL BLOCK WALL
DETAIL. COORDINATE
CONDUIT INSTALLATION WITH
STRUCTURAL AND CIVIL.
E-501
E16929No.
NOTES
1. POWER AND COMMUNICATION PITS SHALL BE
ENTIRELY CLASS D. INCLUDING THE PIT LID AND SCEC
APPROVED.
2. REFER TO STRUCTURAL DRAWINGS FOR CONDUIT
RETICULATION AND SLAB COORDINATION FOR FLOOR
BOXES.
3. LIGHTNING PROTECTION AIR TERMINAL SHALL BE
POINTED WITH A NOMINAL DIAMETER OF 14mm WITH
M16 THREAD. MATERIAL SHALL BE COPPER. AIR
TERMINAL SHALL BE APPROPRIATELY FIXED TO DOWN
CONDUCTOR VIA TERMINAL BASE. DOWN CONDUCTOR
SHALL BE STRANDED Cu 35mm² HELD TO EXTERIOR
WALL BY CLAMPS WITH NO MORE THAN 1M SPACING.
4. AIR TERMINAL CONDUCTOR SHALL BE STRANDED
35mm2 AND HELD DOWN TO ROOF VIA HOLD DOWN
CLAMPS. CABLE SHALL RUN ALONG ROOF VIA AIR
TERMINALS AS SHOWN IN E-151.
5. 300mm X 300mm ROOFING PANEL SUPPLIED BY
ROOFING CONTRACTOR. SECURE ROOF PANEL TO
ROOF SYSTEM WITH ADHESIVE SUPPLIED BY ROOFING
CONTRACTOR AND UNDER THEIR DIRECTION. SECURE
POINT BASE/CABLE CLIP TO ROOFING LABEL WITH
SILICON ADHESIVE. DO NOT PUNCTURE ROOFING
SYSTEM.
6. EARTH ROD PIT WITH DIMENSIONS 200 x 200 x 150mm
WITH CONCRETE LID AND SHALL INCLUDE ALL
NECESSARY BONDING AND CONNECTING EQUIPMENT,
EARTH BAR, DISCONNECTING LINKS ETC.
7. CABLE TRAY SHALL BE OF BASKET TYPE WHEN
CARRYING COMMUNICATION CABLING. CABLE TRAY
SHALL BE OF LADDER TYPE WHEN CARRYING POWER
CABLING.
8. ALL HOLES FOR ELECTRICAL SERVICES MUST BE CUT
OR DRILLED, NOT PUNCHED.
9. ALL GAPS SEALED WITH A SUITABLE NON-HARDENING
MASTICS SEALANT (BOSTIK FIRE BAN 1 OR RAMSET
BLAZEBRAKE).
10. ALL BUILDING PENETRATIONS FROM INCOMING PITS
ARE AS PER DCCS.PARA.53-I, A MINIMUM OF 100MM
INSIDE-DIAMETER GALVANISED IRON PLATED CONDUIT
FOR ALL BUILDING PENETRATIONS.
11. COMMUNICATION PITS TO CONFIRM TO DCCS
REQUIREMENTS. ENSURE APPROPRIATE DRAINAGE
FOR ALL PITS, INTO ROCK BEDS UNDERNEATH.
CABLE TRAY
UNDERSIDE OF SLAB
IBS FOAM ROD WEDGED IN.
SEALED WITH A SUITABLE
NON-HARDENING MASTICS
SEALANT. BOTH SIDES. NO GAP
GREATER THAN 12mm.
IBS FOAM ROD WEDGED IN.
SEALED WITH A SUITABLE
NON-HARDENING MASTICS
SEALANT. BOTH SIDES. NO GAP
GREATER THAN 12mm.
Ø50mm STEEL CONDUIT
MAX.
GAP INSIDE THE CONDUIT CAN
EITHER BE PACKED WITH
INSULATION (TO ALLOW FUTURE
CABLE RETICULATION) OR
SEALED WITH MASTIC. BOTH
SIDES.
BUNCHED CABLES
PIPE/CONDUIT
IF THE GAP AROUND CONDUIT/PIPE
IS LESS THAN 20mm, USE A
BACKING ROD THEN SEAL WITH
RESILIENT, NON HARDENING
MASTIC TO A DEPTH OF 20mm, BOTH AT THE BOTTOM AND TOP OF
THE SLAB. IF THERE IS A LARGE
PENETRATION WHICH MAY BE
IRREGULAR THEN YOU CAN EITHER
FILL THE CAVITY WITH GROUT OR
YOU CAN PACK THE CAVITY WITH
POLYESTER INSULATION, THEN
TWO SHEETS OF PLASTERBOARD
OR 6mm FIBROUS CEMENT SHEET
SHOULD BE FIXED TO THE SLAB TO
FORM A SOUND RESISTANT SEAL.
SLAB
PIPE/CONDUIT
COLLAR INSTALL TO
MANUFACTURERS
SPECIFICATION. TO SUIT
PIPE/CONDUIT
IF GAP BETWEEN
PIPE/CONDUIT & CORED HOLE
IS GREATER THAN 12mm, BACKFILL WITH MORTAR , FOR
GAPS LESS THAN 12mm SEAL
WITH APPROPRIATE SEALANT
MAIN SWITCH BOARD (MSB) (G1115 / 1)
OCCUPIED
SERVICES
MAIN SWITCH
125A
200A MINIMUM
FORM 2b TO AS61439.1
MIN. POLES 48 POLES ON EACH BUS BAR
MIN. FAULT LEVEL 20kA (TBC BASE TINDAL ELEC)
IP42 TO AS60529
MIN. BUS SIZE 250A
PRIVATE METERM
SURGE DIVERTER
E
MEN
LINK
N
UNOCCUPIED
SERVICES MAIN
SWITCH
150A
200A MINIMUM
MDB
UNOCCUPIED SERVICE
SECTION
MAIN
SWITCH
250A
10A
SECURITY
CONTROL
PANEL
SEC
63A
DB-TEF
30%
SPARES
MECHANICAL
SERVICES
SWITCHBOARD
(MSSB)
125A 150A
63A
OCCUPIED SERVICE
SECTION
SPARE
250A
415V 415V
415V
METER SHALL
INTERFACE WITH SITE
BMS AND PCMS
10A
20A
3kVA 230/120V
US-STYLE
NEMA
5-20
DUPLEX
OUTLET
SS35
NO. CABLE SCHEDULE
185mm² Cu XLPE 4x1C
70mm² Cu WS52W 4C + E
16mm² Cu WS52W 4C + E
16mm² Cu XLPE 4C + E
6mm² Cu WS52W 2C + E
235 4
E-601
E16929No.
GENERAL SHEET NOTES
1. SWITCHBOARD AND CABLING SHALL COMPLY WITH THE
REQUIREMENTS OF AS/NZS 3000 AND AS/NZS 61439.1
2. ALL SWITCHGEAR EQUIPMENT ARE TO BE THE SAME
MANUFACTURER TO PROVIDE ENHANCED PROTECTION.
3. PROTECTION SETTINGS TO GRADE WITH SUPPLY SUBSTATION
PROTECTION. PROVIDE FINAL GRADING STUDY FOR APPROVAL.
4. SURGE DIVERTERS SHALL BE SIZED ACCORDING TO AS/NZS
3000, TYPICALLY 100 kA PER PHASE FOR AN 8/20uS IMPULSE.
SURGE DIVERTER SHALL BE PROTECTED IN ACCORDANCE WITH
MANUFACTURER RECOMMENDATION.
5. PRIVATE MULTIFUNCTION METERS ARE TO BE CLASS 2
ACCURACY AND PROVIDE ENERGY, VOLTAGE, MAXIMUM
DEMAND AND POWER FACTOR DATA. ALL METERS MUST MATCH
MIEE AND THE NATIONAL SUB-METER PROGRAM
REQUIREMENTS.
6. PROVIDE CIRCUIT BREAKER SPACE FOR FUTURE UPGRADES.
7. M.E.N SYSTEM TO BE BONDED IN ACCORDANCE WITH AS/NZS
3000.
8. MINIMUM LIGHTING SUB-CIRCUITS SHALL BE 2.5mm². MINIMUM POWER SUB-CIRCUITS SHALL BE 4mm².
9. LIGHTNING PROTECTION EARTH SYSTEM SHALL BE CONNECTED
INTO THE MEN VIA MAIN EARTH PIT.
10. ALL METERS SHALL BE OF THE SMART TYPE AND CONNECTED
INTO THE SITE MONITORING VIA THE TEF ROOM.
11. CONNECT TO EXISTING SPARE CIRCUIT BREAKER POSITION.
COORDINATE SHUT-DOWN OF SUBSTATION TO MAKE
CONNECTION WITH SITE.
12. PROVIDE A 3kVA STEP DOWN TRANSFORMER 230V/120V
LOCATED IN THE ELECTRICAL ROOM. THE TRANSFORMERS
SECONDARY SIDE SHALL HAVE A 20A CIRCUIT BREAKER WHICH
FEEDS A USA STYLE NEMA 5-20 DUPLEX OUTLET LOCATED AT
THE STATCOM PAD.
13. PROVIDE 300H x 400W 12 POLE ENCLOSURE TO HOUSE
TRANSFORMER SECONDARY CIRCUIT BREAKER. CIRCUIT
BREAKER TO BE NEMA APPROVED.
MAIN DISTRIBUTION BOARD (MDB) - SINGLE LINE DIAGRAM
NOT TO SCALE
(MDB)
MAIN DISTRIBUTION BOARD
G1115/1.1
SURGE DIVERTER
FORM 2 TO AS61439.1
IP42 TO AS60529
SUPPLY FROM MSB
20A20A
MAIN SWITCH
100A
P2 - OFFICE AMU
P12 - OPS DESK
MIN. FAULT LEVEL 10kVA
MIN. POLES 48
MIN. BUS RATING 200A
P6 - FLOOR BOXES
P8 - HWU
P10 - FRIDGE
P1 - AMU ADMIN
P3 - LSE
P5 - MISSION PLANNING
P7 - CREW MEETINGS & MISSION PLANNING
P9 - MICROWAVE
P11 - TOILETS & BREAK ROOM
P14 - MASS BRIEFINGP13 - OPS OFFICES
P4 - CREW MEETING
P16 - MASS BRIEFINGP15 - DUTY OFFICER
COMMUNICATIONS DISTRIBUTION BOARD (DB-TEF) - SINGLE LINE DIAGRAM
NOT TO SCALE
(DB-TE)
COMMUNICATIONS DISTRIBUTION BOARD
G1115/1.2
SURGE DIVERTER
FORM 2 TO AS61439.1
IP42 TO AS60529
SUPPLY FROM MSB
MAIN SWITCH
63A
P2 - COMMUNICATIONS
MIN. FAULT LEVEL 10kVA
MIN. POLES 24
MIN. BUS RATING 200A
P1 - COMMUNICATIONS
MECHANICAL SERVICES SWITCHBOARD (MSSB) - SINGLE LINE DIAGRAM
NOT TO SCALE
(MSSB)
MECHANICAL SERVICES SWITCHBOARD
G1115/1.3
SURGE DIVERTER
FORM 2 TO AS61439.1
IP42 TO AS60529
SUPPLY FROM MSB
40A40A
10A
10A
10A
10A
32A
MAIN SWITCH
150A
M DIGITAL CURRENT METER
P2 - DEDICATED OUTDOOR AIR SYSTEM 1
40A
P12 - INSTANTANEOUS WATER HEATER
MIN. FAULT LEVEL 10kVA
MIN. POLES 36
MIN. BUS RATING 200A
10A
10A
P6 - EXHAUST FAN
32A
P8 - AIR HANDLING UNIT 1
32A
P10 - AIR COOLED CONDENSER UNIT 3
P1 - AIR COOLED CONDENSER UNIT 1
P3 - AIR COOLED CONDENSER UNIT 2
P5 - BOOSTER PUMP
P7 - EXHAUST FAN
P9 - EXHAUST FAN
P11 - AIR COOLED CONDENSER UNIT 4
P4 - BOOSTER PUMP
20A20A
20A20A
20A20A
20A20A
20A20A
20A20A
20A20A
32A
32A32A
P17 - ELECTRICAL ROOM
20A
P17 - AIR COOLED CONDENSER UNIT 5
P4 - COMMUNICATIONS
16A 16A
P14 - MAINTENANCE GPOSP13 - MAINTENANCE GPOS
16A 16A
P16 - VAV BOXES (NOTE 12)(NOTE 12) P15 - VAV BOXES
NO. CABLE SCHEDULE
10mm² Cu WS52W XLPE
16mm² Cu WS52W XLPE 4C+E
6mm² Cu WS52W XLPE 4C+E
10mm² Cu XLPE
SPARE
(NOTE 4)
(NOTE 4)
(NOTE 4)
10A
16A16A
16A
16A
16A
16A
L2 - CARPARK LIGHTING
16A
L4 - CREW MEETING & TEF/COMMS ROOM
16A
L6 - BREAK ROOM & MECHANICAL ROOM
16A
L8 - OPS DESK, OPS OFFICES & HALLWAY
16A
L10 - DUTY OFFICER & HALLWAY
L1 - EXTERNAL LIGHTING
L5 - MISSION PLANNING & CREW MEETING
L7 - TOILETS
L9 - MASS BRIEFING
SPARE
SPARE
SPARE
L3 - AMU ADMIN, OFICE AMU, LSE & ELECTRICAL ROOM
M DIGITAL CURRENT METER
M DIGITAL CURRENT METER
32A
SPARE
P18 - WASTE WATER PUMP
SPARESPARE
SPARESPARE
SPARESPARE
10A
P18 - DDC
10A
P20 - ACCU-1/AHU-1 CONTROL PANEL
10A
P19 - DOAS-1 CONTROL PANEL
P5 - DESN / FIP RACK
32A
RACK 1 (USAF)
P3 - COMMUNICATIONS
RACK 1 (AUS)
RACK 2 (USAF)
ROOM GPOS
SPARE
SPARE
& TEF/COMMS ROOM
LCR1
16A
L11 - PATHWAY LIGHTING
LCR1
ELCREMERGENCY LIGHTING
ELCREMERGENCY LIGHTING
ELCREMERGENCY LIGHTING
ELCREMERGENCY LIGHTING
ELCR EMERGENCY LIGHTING
ELCR EMERGENCY LIGHTING
ELCR EMERGENCY LIGHTING
ELCR EMERGENCY LIGHTING
LCR1
16A
32A
32A 32A
32A 32A
P7 - COMMUNICATIONS
RACK 1 (USAF)
P8 - COMMUNICATIONS
RACK 1 (AUS)
P6 - COMMUNICATIONS1
RACK 2 (USAF)
SPARE
P19 - GPO FOR FUTURE
SECURITY EQUIPMENT
20A
MIN. 25% SPARE POLE CAPACITY
MIN. 25% SPARE POLE CAPACITY
MIN. 25% SPARE POLE CAPACITY
E-602
E16929No.
NOTES
1. SWITCHBOARD AND CABLING SHALL COMPLY WITH THE
REQUIREMENTS OF AS/NZS 3000 AND AS/NZS 61439.1
2. ALL SWITCHGEAR EQUIPMENT ARE TO BE THE SAME
MANUFACTURER TO PROVIDE ENHANCED PROTECTION.
3. PROTECTION SETTINGS TO GRADE WITH SUPPLY SUBSTATION
PROTECTION. PROVIDE FINAL GRADING STUDY FOR APPROVAL.
4. SURGE DIVERTERS SHALL BE SIZED ACCORDING TO AS/NZS
3000, TYPICALLY 100 kA PER PHASE FOR AN 8/20uS IMPULSE.
SURGE DIVERTER SHALL BE PROTECTED IN ACCORDANCE WITH
MANUFACTURER RECOMMENDATION.
5. PRIVATE MULTIFUNCTION METERS ARE TO BE CLASS 2
ACCURACY AND PROVIDE ENERGY, VOLTAGE, MAXIMUM
DEMAND AND POWER FACTOR DATA.
6. PROVIDE 25% SPARE POLES FOR CIRCUIT BREAKERS FOR
FUTURE UPGRADES.
7. PROVIDE IES RECIPROCALS TO COMMUNICATIONS RACK. WITH
RACK EQUIPMENT AND RACK UPS TO BE PROVIDED BY OTHERS.
8. ENSURE LOADS ARE BALLANCED ACROSS ALL PHASES.
9. REFER TO MECHANICAL FUNCTION SPECIFICATION FOR DETAILS
ON MECHANICAL SERVICES SWITCHBOARD.
10. ALL METERS SHALL BE OF THE SMART TYPE AND CONNECTED
INTO THE SITE MONITORING VIA THE TEF ROOM.
11. UNLESS SPECIFIED CABLE SIZE TO BE 2.5mm² PVC FOR SINGLE
PHASE CIRCUITS.
12. COORDINATE WITH MECHANICAL DESIGN AND INSTALLER FOR
LOCATION OF VAV BOXES. SPLIT POWER SUPPLY TO VAV BOXES
BETWEEN P15 & P16 USING 2.5mm2 2C+E.
TYPICAL VAV POWER CIRCUIT
NO SCALE
CB 'A'
16A
CB 'A' VAV BOX
LOCAL VAV SWITCH
(INSTALLED NEAR VAV BOX)
EMERGENCY LIGHTING ACTIVATION & TEST CIRCUIT TO AS2293
NOT TO SCALE
PART DB
6A CONTROL
RESET TEST
T1.1
T1
TIMER
RESET
0-180 min
SET TO 120
N
ELCR
AC3
NC
EM
L1
EM
L2
EM
L3
L2 L3
LIGHT
CONTROL
RELAY
No.1
EXTERNAL
LIGHTING
TYPICAL LIGHTING CONTROL DIAGRAM
NOT TO SCALE
TYPICAL PIR CIRCUIT DETAIL
NOT TO SCALE
30mA
PIR
SENSOR
230V
LIGHTING CIRCUIT
(LUMINAIRES)
PIR
No. OF PIR'S TO SUIT
LIGHTING CIRCUIT.
16A
24Hr
TIMER
N
PE CELL
PER
PE
16A 30mA
LCR1
PER/1
T1
T1/1
AUTO ON
OFF
TIMER
LIGHTING CONTROL
PURPOSE TIME 'ON' CONTROL 'OFF' CONTROL
- INTERNAL LIGHTING BUSINESS HOURS PIR MOTION SENSORS RUN TIME 30MIN (ADJUSTABLE)
- INTERNAL LIGHTING BUSINESS HOURS LOCAL SWITCHING BY CONTACTOR WITH FSE
OVERRIDE LOCAL SWITCHING BY CONTACTOR WITH FSE OVERRIDE
- PATHWAY - LOCAL SWITCHING BY CONTACTOR WITH FSE
OVERRIDE LOCAL SWITCHING BY CONTACTOR WITH FSE OVERRIDE
- BUILDING PERIMETER
LIGHTING DUSK-DAWN PE CELL AND TIMING CIRCUIT OVER-RIDE ON & OFF SWITCHES
- CARPARK LIGHTING DUSK-DAWN PE CELL AND TIMING CIRCUIT OVER-RIDE ON & OFF SWITCHES
** ALL TIME-SWITCHES TO BE 7-DAY PROGRAMMABLE TYPE (MIN 4 CHANNEL) WITH 100 HOURS BATTERY RESERVE PROGRAMMED TO SUIT CLIENT REQUIREMENTS. WHERE TIMES ARE SUGGESTED IN THE TABLE ABOVE, THEY ARE ONLY INDICATIVE AND FINAL OPERATION HOURS ARE TO BE CONFIRMED WITH THE CLIENT AND PROGRAMMED TO
SUIT THEIR REQUIREMENTS.
USAF
RACK 1
SECURE
USAF
RACK 2
UNSECURE
AUS
RACK 3
DPN
TYPICAL
DATA
OUTLETS
SECURED AREA
UNSECURED AREA
TO SATELLITE
PAD
TO SATELLITE
PAD
TELECOMMUNICATIONS - BLOCK DIAGRAM
NOT TO SCALE
NOTES:
1. CABLES FROM EACH RACK TO BE
PHYSICALLY SEPARATED BY
DIFFERENT CABLE TRAYS
DESCRIBED IN E-121.
2. DOUBLE DATA OUTLETS
INDICATIVELY SHOWN SHARING /
SPLITTING TWO COMMUNICATION
SERVICES. EACH DOUBLE DATA
OUTLET SHOULD PROVIDE TWO
DESCRIBED SERVICES. USAF
SECURE AND UNSECURE WITHIN
THE SECURED AREA. AND USAF
UNSECURED AND AUS DPN WITHIN
THE UNSECURED AREA. OUTLETS
SHOULD APPROPRIATELY LABEL
SERVICES.
1x48 STRAND SOF FOR
DESN/BMS CONNECTION
TO BASE NETWORK
(NOTE 3)SPARE
RACK
DESN
E-603
E16929No.
NOTES
1. CONTRACTOR TO PROVIDE AND INSTALL 42 RU COMMUNICATIONS RACK.
CLIENT SHALL PROVIDE RACK EQUIPMENT. CONTRACTOR SHALL CONNECT
SPECIFIED OUTLETS TO RACK UPS SUPPLIED BY CLIENT.
2. FIBRE TO TERMINATE AT BUILDING 390. REFER TO DRAWING E-101 FOR CABLE
ROUTE.
3. COORDINATE DESN/BMS WITH BROAD SPECTRUM. FIBRE TO TERMINATE AT
SITE BMS CONTROLLER. REFER TO DRAWING E-101 FOR CABLE ROUTE.
4. ALL DESN/BMS SERVICES CONNECTING IN INTO BASE NETWORK MUST DO SO
VIA BLACK FIBRE TIE AT BUILDING COMMUNICATIONS RACK.
5. OUTLETS SHALL BE APPROPRIATELY LABELLED TO DENOTE WHICH RACK
THEY ARE SUPPLIED BY.
6. COORDINATE POWER SUPPLY TO VAV BOXES AND HVAC EQUIPMENT WITH
MECHANICAL EQUIPMENT CONTRACTOR.
RESERVED SPACE FOR
OWNER EQUIPMENT
(TYPICAL)
EQUIPMENT SUPPORT RAILS
(TYPICAL)
VENTED SHELF
(TYPICAL)
TYPICAL DATA RACK
FINISHED FLOOR
US
AF
S
AT
CO
M
AU
S
DP
N
P-700 P-400
US
AF
S
AT
CO
M
AU
S
DP
N
CONDUIT ROUTE
TO BLDG 390 BY
OTHERS
CONDUIT ROUTE
TO BLDG 452 BY
OTHERS
USAF
SATCOM
(BY
OTHERS)
(FUTURE) P-500
M13 x 74mm EMBEDMENT
EXPANSION…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .