1665827-P-700 Drawings - 2 of 2.pdf

PDF 23 MB Posted

Attached to
FY22 MCAF PAF180700 SQUADRON OPERATIONS FACILITY, ROYAL AUSTRALIAN AIR FORCE BASE TINDAL, AUSTRALIA
Solicitation number
N6274223R1316
Issued by

View the file

Other files

File Type Posted
23R1316 Note 6.pdf PDF
23R1316_AMD6.pdf PDF
23R1316_AMD5.pdf PDF
23R1316 Note 5.pdf PDF
23R1316_AMD4.pdf PDF
23R1316 Note 4.pdf PDF
23R1316 AMD3.pdf PDF
23R1316_AMD2.pdf PDF
23R1316 Note 3.pdf PDF
P700 SV Sign-in.pdf PDF
23R1316_AMD1.pdf PDF
23R1316 Note 2.pdf PDF
23R1316 Note 1.pdf PDF
1665827-P700 Specification_Signed_REV_MAY2023.pdf PDF
1665827-P-700 Drawings - 1 of 2.pdf PDF
23R1316-RFP.pdf PDF
Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 2 3 4 5 6 87

F

B

A

E

D

C

S-105

C044138No.

DATE: 03/17/2023

Evan Mizue

1 2 3 4 5 6 87

FBA EDC

B

S-201

C044138No.

FIXING DESIGN OF THE INSULATED METAL PANELS SHALL BE BY THE

SUPPLIER / BUILDER. SUBMIT TO THE CONTRACTING OFFICER FOR REVIEW.

ABCDEF

ABCDEF

ABCDEF

S-202

C044138No.

PLAN - TEE

4-N16 'L' BARS (TOP &

BTM) LAPPED WITH

LONGITUDINAL BARS

GROUND BEAM

REINFORCING

AS SPECIFIED

PLAN - CORNER

3-N16 'L' BARS (BTM)

LAPPED WITH

LONGITUDINAL BARS

BP

IJ

R8-200

S-301

C044138No.

CHEMICAL WATERPROOFING

TO FIRST COURSE. REFER

DETAILS ON DRAWING S-301.

S-401

C044138No.

NOTE: TRUSS HOLD-DOWN BOLT LOCATIONS TO ALIGN WITH ENGAGED PIERS IN

BLOCKWORK WALL, AS DETAILED ON DRAWING S-102.

OR1

S-501

C044138No.

D

S-502

C044138No.

E-001

SCHEMATICS

CONTACTOR

CIRCUIT BREAKER

EARTH

METER

SURGE DIVERTER

MEN LINK

M

SEC

ABBREVIATIONS

AB ABOVE BENCH

AD ABOVE DOOR

ACCU AIR COOLED CONDENSER UNIT

BP BOOSTER PUMP

CHIL CHILLER

DOAS DEDICATED OUTDOOR AIR SYSTEM

EF EXHAUST FAN

EWH INSTANTANEOUS WATER HEATER

FCU FAN COIL UNIT

FDCIE FIRE DETECTION CONTROL AND INDICATING EQUIPMENT

FR FRIDGE

HD HAND DRYER

HTC HYDRONEUMATIC TANK COMPRESSOR

HWU HOT WATER UNIT

MW MICROWAVE

OWS OCCUPANT WARNING SYSTEM

PA PUBLIC ADDRESS

POC POINT OF CONNECTION

SMOF SINGLEMODE FIBRE OPTIC

TX TRANSFORMER

WWP WASTE WATER PUMP

COMMUNICATIONS

DATA OUTLET

2 DENOTES DOUBLE OUTLET

COMMUNICATIONS RACK (CLASS C RACK FOR AUSTRALIAN CABINETS)

1x300mm COMMUNICATIONS CABLE TRAY

AUSTRALIAN - UNSECURED

1x300mm COMMUNICATIONS CABLE TRAY

USAF - UNSECURED

1x300mm COMMUNICATIONS CABLE TRAY

USAF - SECURED

1x300mm COMMUNICATIONS CABLE TRAY SECURITY

COMMUNICATION CONDUITS

SECURITY CONDUITS

LOCKABLE COMMUNICATIONS PIT

CLASS D PIT MIN 1250mm x 450mm x 950mm. SCEC

ENDORSED WITH SCEC ENDORSED LID. UNLESS

SPECIFICALLY STATED DIFFERENTLY ON DRAWING.

CONTRACTOR TO SUPPLY ALL NECESSARY

ANCILLARY EQUIPMENT.

LIGHTING

23W 2418 lm RECESSED PANEL 4000K, IP54

45W 4500 lm SURFACE MOUNTED BATTEN 4000K, IP65

12W/m 320lm/m LINEAR LED, 4000K, IP67

TO BE MOUNTED IN COVE IN BATHROOMS. LENGTHS SHOWN

ON E131.

19.6W 2050 lm LED RECESSED DOWNLIGHT 4000K IP44

12W 1000 lm EXTERIOR BULKHEAD WALL LIGHT 4000K, IP 66, IK10, PROVIDE ANY NECESSARY SHIELD ACCESSORY TO

PREVENT OBTRUSIVE UPLIGHT.

6200lm 60W LED STREET LIGHT ON 6m POLE, IP66, IK09, 4000K WITH LIGHTING DISTRIBUTION ST1.2a (WIDE DISTRIBUTION)

POLE TO BE TAPERED, GALVANISED AND EQUIPPED WITH

SERVICE DOOR. POLE FOOTING TO MANUFACTURERS

REQUIREMENTS. ENSURE FITTING PROVIDES APPROPRIATE

LIGHTING COVERAGE AT 0 DEGREE TILT ANGLE.

11424lm 86W LED STREET LIGHT ON 6m POLE, IP66, IK09, 4000K, 80CRI WITH LIGHTING DISTRIBUTION TYPE III MEDIUM.

POLE TO BE TAPERED, GALVANISED AND EQUIPPED WITH

SERVICE DOOR. POLE FOOTING TO MANUFACTURERS

REQUIREMENTS.ENSURE FITTING PROVIDES APPROPRIATE

LIGHTING COVERAGE AT 0 DEGREE TILT ANGLE.

360° MOTION DETECTOR

PE CELL

L1

L2

D1

W1

LIGHTNING PROTECTION

AIR TERMINAL, 600mm IN LENGTH

EARTH ELECTRODE

AIR TERMINAL CONDUCTOR

DOWN CONDUCTOR

EARTH RING CONDUCTOR

EARTH PIT

MAIN EARTH PIT

NOTES

1. DRAWINGS ARE TO BE READ IN CONJUNCTION WITH

THE ELECTRICAL SPECIFICATION AND MIEE

DOCUMENTS.

2. DRAWINGS ARE TO BE READ IN CONJUNCTION WITH

OTHER SERVICES DRAWINGS, INCLUDING BUT NOT

LIMITED TO: STRUCTURAL, CIVIL, MECHANICAL,

HYDRAULIC (PLUMBING), ARCHITECTURE.

SWITCHTING

SWITCH WIRE(NON-ESSENTIAL)

SINGLE 10A LIGHT SWITCH - 1100 AFFL

SINGLE 10A LIGHT SWITCH W/ 1-10V DIGITAL DIMMER - 1100

AFFL

SECURITY

ACCESS PANEL

SECURITY PANEL

SPEAKERS

C C

C

CT1

CT2

CT3

L3

CT4

P1

P2

S

ELECTRICAL SYMBOLS LEGEND ELECTRICAL GENERAL NOTES

E16929No.

POWER

SINGLE 10A SWITCHED SOCKET OUTLET (SSO)

DOUBLE 10A SWITCHED SOCKET OUTLET (DSO)

ISOLATOR. N DENOTES NO. OF POLES. A DENOTES

CURRENT CAPACITY

DISTRIBUTION BOARD (DB)

MAIN SWITCHBOARD (MSB)

MECHANICAL SERVICES SWITCHBOARD (MSSB)

xN,xA

FLOOR BOX (FLUSH, STAINLESS STEEL BOX LID)

2 x DOUBLE GPO 2 x DOUBLE DATA

1x300mm CABLE TRAY

(UNISTRUT SUPATRAY ST3 AUG2A330 OR APPROVED EQUAL)

ELECTRICAL CABLE PIT

TYPE 99 900mm X 900mm WITH CLASS D LID UNLESS SPECIFICALLY

STATED DIFFERENTLY ON DRAWING - SUPPLY ACO PIT RISER TO

ALLOW CONDUITS TO ENTER PIT AT 600mm BELOW GROUND

ELECTRICAL CABLE PIT

TYPE 33 353mm X 353mm x 444mm WITH CLASS D UNLESS SPECIFICALLY

STATED DIFFERENTLY ON DRAWING - SUPPLY ACO PIT RISER TO

ALLOW CONDUITS TO ENTER PIT AT 600mm BELOW GROUND

ELECTRICAL CONDUITS

EMERGENCY & EXIT LIGHTING

EMERGENCY EXIT SIGN (STRAIGHT AHEAD). SUFRACE MOUNTED.

24M VIEWING DISTANCE.

DS DENOTES DOUBLE SIDED.

EMERGENCY EXIT SIGN (DIRECTIONAL). SUFRACE MOUNTED.

24M VIEWING DISTANCE.

DS DENOTES DOUBLE SIDED.

EMERGENCY LIGHT (RECESSED)

C0: D40 C90: D40

EMERGENCY LIGHT (SURFACE MOUNTED)

C0: D40 C90: D40

E

E2

E

EN

WALL

CONSTRUCTION

INSTALLATION AND

CONCEALED

CABLING FACILITES

RENDERED MASONARY

PARTITION

SURFACE MOUNTED BOX WITH CONDUIT CHASED

INTO WALL

FACE BRICK EXTERNAL

CAVITY WALL

SURFACE MOUNTED BOX WITH THERMOPLASTIC

INSULATED CABLES IN CONDUIT RUN IN CAVITY AND

TIED AGAINST INNER BRICK SURFACE, OR

THERMOPLASTIC SHEATHED CABLES RUN IN CAVITY

STUD PARTITION REWIRABLE

1.GENERAL

1.1 ADDITIONAL WORK

QUALITY

WORKS BEYOND THE SCOPE OF THIS SPECIFICATION: TO THE GENERAL QUALITY

OF THIS FITOUT SPECIFICATION.

1.2 AUTHORITIES

COMPLIANCE

CONFORM TO THE FOLLOWING:

THE BUILDING CODE OF AUSTRALIA.

ANY BUILDING APPROVALS.

THE REQUIREMENTS OF LOCAL AND STATE OR TERRITORY GOVERNMENT

AUTHORITIES.

THE RELEVANT REQUIREMENTS OF THE AUSTRALIAN DEPARTMENT OF

DEFENCE.

SPECIFICATIONS

MIEE & MFPE

ELECTRICAL WORKS: USE ONLY STATE OR TERRITORY LICENSED PERSONNEL.

2.EXECUTION

2.1 SERVICES INSTALLATION

PENETRATIONS AND FIXING

FIXING: IF EQUIPMENT IS NOT SUITABLE FOR FIXING TO NON-STRUCTURAL

BUILDING ELEMENTS, FIX DIRECTLY TO STRUCTURE AND TRIM AROUND HOLES

OR PENETRATIONS IN NON-STRUCTURAL ELEMENTS.

GENERAL: IF IT IS PROPOSED TO PENETRATE OR FIX TO THE FOLLOWING,

SUBMIT DETAILS OF THE METHODS PROPOSED TO MAINTAIN THE REQUIRED

STRUCTURAL, FIRE AND OTHER PROPERTIES:

STRUCTURAL BUILDING ELEMENTS INCLUDING EXTERNAL WALLS, FIRE

WALLS, FIRE DOORS AND ACCESS PANELS, OTHER TESTED AND RATED

ASSEMBLIES OR ELEMENTS, FLOOR SLABS AND BEAMS.

MEMBRANE ELEMENTS INCLUDING DAMP-PROOF COURSES,

WATERPROOFING MEMBRANES AND ROOF COVERINGS. IF PENETRATING

MEMBRANES, PROVIDE A WATERPROOF SEAL BETWEEN THE MEMBRANE

AND THE PENETRATING COMPONENT.

FIRE RATED BUILDING ELEMENTS: SEAL PENETRATIONS WITH A SYSTEM

CONFORMING TO AS 4072.1.

NON-FIRE RATED BUILDING ELEMENTS: SEAL PENETRATIONS AROUND

CONDUITS AND SLEEVES. SEAL AROUND CABLES WITHIN SLEEVES. IF THE

BUILDING ELEMENT IS ACOUSTICALLY RATED, MAINTAIN THE RATING.

PIPE SLEEVES: IF PIPING OR CONDUIT PENETRATES BUILDING ELEMENTS,

PROVIDE METAL OR PVC SLEEVES FORMED FROM OVERSIZE PIPE SECTIONS.

ALL WIRING AND CABLING SHALL BE CONCEALED WITHIN WALLS, CEILING VOIDS

AND FINISHES. ACCESSORIES AND CONDUITS MUST BE INSTALLED AS SURFACE

MOUNTED.

2.2 COMPLETION

PROJECT FOLDER

PROVIDE A PROJECT FOLDER CONTAINING THE FOLLOWING:

• RECORD DRAWINGS OF WORKS AS BUILT.

• PRODUCT DATA WITH MAINTENANCE AND CLEANING INSTRUCTIONS.

• PRODUCT WARRANTIES

ELECTRICAL INSTALL

1.GENERAL

1.1 RESPONSIBILITIES

QUALIFICATION

GENERAL: USE ONLY PERSONS APPROPRIATELY EXPERIENCED AND QUALIFIED

TO UNDERTAKE THE ELECTRICAL DESIGN WORK ON THE SYSTEMS

DOCUMENTED.

PERFORMANCE GENERAL: CARRY OUT VERIFICATION TESTS AND

MEASUREMENTS TO SHOW COMPLIANCE WITH THE SPECIFICATION.

1.2 STANDARDS

GENERAL

ELECTRICAL SYSTEMS: TO AS/NZS 3000 AND SAA HB 301.

TELECOMMUNICATIONS CABLING: TO AS/ACIF S008, AS/ACIF S009, AS/NZS 3080

AND SAA HB 29, MANUAL OF INFRASTRUCTURE ENGINEERING - ELECTRICAL

(MIEE).

DEGREES OF PROTECTION (IP CODE): TO AS 60529.

EMC: TO AS/NZS 61000.

EMERGENCY LIGHTING: TO ASS 2293

2. EXECUTION

2.1 GENERAL

LOCATION

ARRANGEMENT: ARRANGE SERVICES SO THAT SERVICES RUNNING TOGETHER

ARE PARALLEL WITH EACH OTHER AND WITH ADJACENT BUILDING ELEMENTS.

FIXING: IF NON-STRUCTURAL BUILDING ELEMENTS ARE NOT SUITABLE FOR

FIXING EQUIPMENT AND SERVICES TO, FIX DIRECTLY TO STRUCTURE AND TRIM

AROUND HOLES OR PENETRATIONS IN NON-STRUCTURAL ELEMENTS.

INSTALLATION: ACCESSORIES AND CONDUITS MUST BE INSTALLED AS SURFACE

MOUNTED. INSTALL EQUIPMENT AND SERVICES PLUMB, FIX SECURELY AND

ORGANISE RETICULATED SERVICES NEATLY. ALLOW FOR MOVEMENT IN BOTH

STRUCTURE AND SERVICES.

2.2 INSTALLATION OF ACCESSORIES

GENERAL

ACCESSORIES: INSTALL ACCESSORIES IN CONFORMANCE WITH THE

INSTALLATION OF ACCESSORIES TABLE.

FLUSH MOUNTING: PROVIDE FLUSH MOUNTED ACCESSORIES.

LOCATION: CONFIRM THE FINAL LOCATION OF ALL OUTLETS AND EQUIPMENT ON

SITE PRIOR TO INSTALLATION.

DEFAULT MOUNTING HEIGHTS TO CENTRE OF ACCESSORY PLATE:

OUTLETS NOT ON SKIRTING DUCT – 300mm SWITCHES AND CONTROLS – 1100mm

RESTRICTED LOCATION: DO NOT INSTALL WALL BOXES ACROSS JUNCTIONS OF

WALL FRAMES INSTALLATION OF ACCESSORIES TABLE

INSTALLATION OF CEILING MOUNTED APPLIANCES

CONNECTIONS – APPLIANCES: PROVIDE FLUSH MOUNTED OUTLETS ON THE

CEILING NEXT TO SUPPORT BRACKETS.

CONNECTIONS – FIXED EQUIPMENT: PROVIDE CONCEALED PERMANENT

CONNECTIONS.

FIXING: PROVIDE SUPPORT BRACKETS FIXED THROUGH CEILING TO THE

BUILDING STRUCTURE. BRACE APPLIANCES THAT HAVE EXCESSIVE BENDING

MOMENTS, ARE HEAVY OR VIBRATE, TO PREVENT HORIZONTAL MOVEMENT.

2.3 LOW VOLTAGE POWER SYSTEMS

GENERAL

GENERAL: DESIGN AND INSTALL FINAL SUBCIRCUITS TO ALL POWER AND

LIGHTING LOADS. COORDINATE WITH ALL OTHER TRADES FOR POWER SUPPLY

AND CABLE CONDUIT / DUCTING REQUIREMENTS, REFER TO MECHANICAL,

HYDRAULIC AND COMMUNICATIONS DESIGN DOCUMENTATION.

SUBMISSIONS

TECHNICAL DATA: SUBMIT DOCUMENTATION TO FULLY DESCRIBE THE

PROPOSED INSTALLATION. AS A MINIMUM PROVIDE:

SINGLE LINE DIAGRAM,

CERTIFY COMPLIANCE WITH AS/NZS 3000, FOR ELECTRICAL SERVICES.

CIRCUIT SCHEDULES / DB SCHEDULES

ACCESSORIES

GENERAL: PROVIDE, AND AS NECESSARY, RELOCATE THE FOLLOWING:

GENERAL POWER OUTLETS.

ISOLATING SWITCHES.

PROVIDE ALL SOFT WIRING FROM SKIRTING DUCT TO TABLE BOXES

WIRING SYSTEMS

STANDARD: TO AS/NZS 3013.

THERMAL INSULATION: IN WALLS FILLED WITH THERMAL INSULATION, INSTALL

CABLES IN PVC CONDUIT.

POWER CABLES

GENERAL: COPPER CABLE GENERALLY, MULTI-STRANDED. MINIMUM SIZE:

LIGHTING SUBCIRCUITS: 2.5mm2 POWER SUBCIRCUITS: 4mm2 .

FAULT LOOP IMPEDANCE: PROVIDE FINAL SUBCIRCUIT CABLES SELECTED TO

SATISFY THE REQUIREMENTS FOR AUTOMATIC DISCONNECTION UNDER

SHORT-CIRCUIT AND EARTH FAULT/TOUCH VOLTAGE CONDITIONS.

2.4 SWITCHBOARD COMPONENTS

GENERAL: PROVIDE PROPRIETARY SWITCHBOARDS TO THE FOLLOWING AND AS

DOCUMENTED.

STANDARDS

STANDARD: TO MIEE CHAPTER 11 & AS/NZS 61439.1

DOORS

GENERAL: PROVIDE LOCKABLE DOORS WITH A CIRCUIT CARD HOLDER UNLESS

ENCLOSED IN CUPBOARDS OR IN AN AREA WHICH IS NOT READILY ACCESSIBLE

TO THE PUBLIC.

FINISHES

INTERIOR: WHITE.

EXTERIOR: MANUFACTURERS STANDARD FINISH.

VENTILATION

GENERAL: REQUIRED TO MAINTAIN DESIGN OPERATING TEMPERATURES AT FULL

LOAD.

DISTRIBUTION BOARD COMPONENTS

PROTECTIVE DEVICES

GENERAL: SELECT AND ADJUST PROTECTIVE DEVICES TO GRADE AND

COORDINATE FOR OVERCURRENT, AND EARTH FAULTS.

REQUIREMENT: AS NECESSARY PROVIDE PROTECTIVE DEVICES WHICH GRADE

AND COORDINATE FOR OVERCURRENT, LET THROUGH ENERGY, AND EARTH

FAULTS.

MOULDED CASE AND MINIATURE CIRCUIT BREAKERS

MOULDED CASE BREAKERS: TO AS/NZS 60947.1, AS 2184 AND AS 60947.2.

MINIATURE CIRCUIT BREAKERS: TO AS/NZS 60898.1 OR AS 3111.

TRIP TYPE

FAULT CAPACITY > 10 KA: TO AS 60947.2 AND AS/NZS 60947.1.

FAULT CAPACITY < 10 KA, CURRENT RATING < 100 A: MINIATURE OVERCURRENT

CIRCUIT BREAKERS TO AS/NZS 60898.1 OR AS 3111 CLIP TRAY CHASSIS.

FOR MINIATURE OVERCURRENT CIRCUIT BREAKERS PROVIDE CLIP TRAY

ASSEMBLIES CAPABLE OF ACCEPTING SINGLE, DOUBLE, OR TRIPLE CIRCUIT

BREAKERS, AND RELATED BUSBARS. PROVIDE MOULDED CLIP-ON POLE FILLERS

FOR UNUSED PORTIONS.

RESIDUAL CURRENT DEVICES

INTEGRAL TYPE: INCORPORATE EARTH LEAKAGE IN CIRCUIT BREAKER

PROTECTION OPERATION TO AS/NZS 61009.1.

MAXIMUM TRIPPING CURRENT: 30 mA.

CONTACTORS

STANDARD: TO AS/NZS 60947.4.1.

RATED OPERATIONAL CURRENT: FULL LOAD CURRENT OF THE LOAD

CONTROLLED.

MINIMUM RATING: 16 A.

2.5 LIGHTING

SCOPE

SCOPE: LIGHTING AND LIGHTING CONTROL HAVE BEEN DESIGNED AND

SPECIFIED TO AS 1680, AS 1158, BCA 2019 AND MIEE CHAPTER , CONSIDERING

ENERGY EFFICIENCY, PERFORMANCE, ESD AND ENVIRONMENTAL IMPLICATIONS.

GENERAL

GENERAL: CONTRACTOR TO SUPPLY AND INSTALL NEW LIGHTING AS REQUIRED

TO SUIT SPECIAL FUNCTIONAL REQUIREMENTS.

INTERIOR LIGHTING STANDARD: TO AS/NZS 1680 PARTS 1, 2.1, 2.2, AS 1680.3 AND

AS1680.5.

PROPRIETARY EQUIPMENT: PROVIDE ONLY PROPRIETARY LUMINAIRES, FITTINGS

AND ACCESSORIES.

MINIMUM ENERGY PERFORMANCE STANDARDS

GENERAL: TO AS/NZS 4783.2 AND AS/NZS 4782.2.

LAMPS

LAMPS: PROVIDE ALL LUMINAIRES COMPLETE WITH LAMPS AND ACCESSORIES.

VERIFY OPERATION: INSTALL LAMPS IN ALL LUMINAIRES AND VERIFY CORRECT

OPERATION BEFORE COMPLETION.

COLOUR RENDERING: GROUP 1B TO AS/NZS 1680.1.

COLOUR CORRECTED TEMPERATURE: 4000°K.

LOW VOLTAGE LAMPS: PROVIDE LAMPS IN CONFORMANCE WITH THE LUMINAIRE

MANUFACTURER’S RECOMMENDATION.

INSTALLATION

SUPPORTS: MOUNT LUMINAIRES ON PROPRIETARY SUPPORTS BY MEANS OF

BATTENS, TRIMS, NOGGINGS, ROSES OR PACKING MATERIAL TO SUIT LOCATION.

RECESSED LUMINAIRES SUPPORT: TO AS 2946.

2.6 EMERGENCY AND EVACUATION LIGHTING

GENERAL

GENERAL: EMERGENCY EVACUATION LIGHTING SYSTEM TO MEET THE

REQUIREMENTS OF THE BCA. TEST AND COMMISSION IN CONFORMANCE WITH

AS/NZS 2293.

PROVIDE COMPUTER MONITOR EMERGENCY LIGHTING AND EXIT SIGNS AS

DOCUMENTED TO MEET THE REQUIREMENTS OF THE BCA AND CONNECTION

INTO SITE BMS SYSTEM. TEST AND COMMISSION IN CONFORMANCE WITH AS/NZS

2293.

LUMINAIRES

EMERGENCY EXIT SIGNS: PROVIDE EMERGENCY EXIT SIGNS AS DOCUMENTED.

GENERAL MAINTAINED AND NON-MAINTAINED LUMINAIRES: PROVIDE

LUMINAIRES AS DOCUMENTED.

OPERATING VOLTAGE: 230V AC.

VISUAL INDICATOR LIGHTS: PROVIDE A RED INDICATOR, READILY VISIBLE WHEN

THE LUMINAIRE IS IN ITS OPERATING LOCATION, WHICH INDICATES THAT THE

BATTERY IS BEING CHARGED.

BATTERIES

TYPE: PROVIDE HIGH TEMPERATURE NICKEL-CADMIUM BATTERIES CAPABLE OF

OPERATING EACH LAMP AT ITS RATED OUTPUT CONTINUOUSLY FOR AT LEAST 2

HOURS DURING COMMISSIONING TESTS AND 1.5 HOURS DURING SUBSEQUENT

TESTS.

BATTERY OPERATED OUTPUT: 70°C.

BATTERY LIFE: AT LEAST 3 YEARS WHEN OPERATING UNDER NORMAL

CONDITIONS AT AN AMBIENT TEMPERATURE OF BETWEEN 10°C AND 40°C AND

SUBJECT TO CHARGING AND DISCHARGING AT 6 MONTHLY INTERVALS.

MARKING: INDELIBLY MARK EACH BATTERY WITH ITS DATE OF MANUFACTURE.

POWER SUPPLY

GENERAL: PROVIDE AN UNSWITCHED ACTIVE SUPPLY TO EACH LUMINAIRE AND

EXIT SIGN, ORIGINATING FROM THE ADJACENT LIGHTING UNSWITCHED ACTIVE

CIRCUIT.

LABELLING

GENERAL: LABEL EACH LUMINAIRE WITH A UNIQUE IDENTIFYING NUMBER.

PROVIDE A LABEL WHICH IS PERMANENTLY FIXED, INDELIBLE AND READABLE AT

A DISTANCE OF 1 M.

EMERGENCY EVACUATION LIGHTING SCHEDULE: RECORD THE NUMBER AND

LUMINAIRE LOCATION IN AN EMERGENCY EVACUATION LIGHTING SCHEDULE

INCLUDED IN THE OPERATION AND MAINTENANCE MANUAL.

TESTS

GENERAL: CARRY OUT TESTS, INCLUDING OUT-OF-HOURS TESTS, TO

DEMONSTRATE THE EMERGENCY AND EVACUATION SYSTEM'S PERFORMANCE.

INCLUDE THE FOLLOWING:

TEST COMPONENTS FOR CORRECT FUNCTION AND OPERATION.

DEMONSTRATE ILLUMINATION PERFORMANCE ON SITE, TO AT LEAST THE

LEVEL STATED IN THE MANUFACTURER'S RECOMMENDATIONS FOR

PERFORMANCE FOR THAT DEVICE.

TEST OPERATION OF BATTERY DISCHARGE TEST AND CONTROL TEST

SWITCH FUNCTIONS, INCLUDING DISCHARGE AND RESTORATION.

DEMONSTRATE SYSTEM FUNCTIONS UNDER MAINS FAIL CONDITION.

DEMONSTRATE OPERATION OF THE BATTERY AND CHARGER INCLUDING A

FULL DISCHARGE/RECHARGE OVER THE DESIGNATED TIME.

MAINS SUPPLY

GENERAL: BEFORE COMMISSIONING, MAKE SURE MAINS SUPPLY HAS BEEN

CONTINUOUSLY CONNECTED FOR AT LEAST 24 HOURS.

2.7 LIGHTING CONTROL

GENERAL

REQUIREMENT: PROVIDE THE FOLLOWING AS DOCUMENTED;

LIGHTING SWITCHES.

AUTOMATIC CONTROL SYSTEMS.

INTERFACE BUILDING LIGHTING CONTROL VIA BMS INTO SITE SYSTEM.

MANUAL CONTROLS

GENERAL: PROVIDE MANUAL CONTROL OF LUMINAIRES INTO GROUPS, ZONES

AND TO INDIVIDUAL DEVICES, AS DOCUMENTED.

DIRECT CURRENT INTERFACE FOR PROXIMITY SENSORS AND AMPLIFIERS: TO

AS/NZS IEC 60947.5.6.

2.8 COMMUNICATION CABLING

GENERAL

GENERAL: PROVIDE A COMPLETE OPERATIONAL TENANCY

TELECOMMUNICATIONS PASSIVE CABLING SYSTEM, TESTED AND

COMMISSIONED IN CONFORMANCE WITH AS/NZS 11801, AS/ACIF S009 AND SAA

HB 29. PROVIDE ACCOMMODATION FOR TELECOMMUNICATIONS CABLING

INFRASTRUCTURE CONFORMING TO AS/NZS 3084 & CIOG REQUIREMENTS.

INCLUDE THE FOLLOWING:

NEW TELECOMMUNICATIONS OUTLETS TO SUIT NEW LAYOUT AND

DESCRIBED SYSTEMS

SYSTEM REQUIREMENTS

APPLICATION CLASS TO AS/NZS 11801 CLAUSE 6.3: E.

BALANCED SYSTEM TO AS/NZS 11801 CLAUSE 7 (DATA): CATEGORY 6.

BALANCED SYSTEM TO AS/NZS 11801 CLAUSE 7 (VOICE): CATEGORY 6.

CONFORMANCE: CERTIFY THE DESIGN AND INSTALLATION FOR CONFORMANCE

WITH AS/NZS 11801 CLAUSE 4.

TESTING OF CABLES TO 'PERMANENT LINK' TO REQUIREMENTS OF AS/NZS 11801

SYSTEM WARRANTY: WARRANT THE SPECIFIED COMMUNICATIONS EQUIPMENT

AND CABLING CHANNEL PERFORMANCE FOR A MINIMUM OF 15 YEARS.

MODULAR CONNECTOR PATCH PANELS

TERMINATIONS: TERMINATE FIXED WIRING DIRECTLY TO THE MODULAR

CONNECTOR.

PATCH CORDS & FLY LEADS: BY IT VENDOR.

EQUIPMENT RACKS

TO BE PROVIDED AND INSTALLED BY US NAVFAC.

CABLE SEPARATION

LOW VOLTAGE CABLES: SEPARATE TELECOMMUNICATIONS CABLES NOT

ENCLOSED IN CONDUITS OR DUCTS FROM LOW VOLTAGE SERVICES BY AT

LEAST 150mm.

ELECTROMAGNETIC INTERFERENCE (EMI): PROVIDE CLEARANCE TO MINIMISE

THE EFFECT OF EMI WHERE COMMUNICATIONS CABLES ARE INSTALLED

PARALLEL AND ADJACENT TO POWER CABLES CARRYING LOADS IN EXCESS OF

200 A.

INSTALLATION

COMMUNICATION INSTALLATION TO COMPLY WITH THE FOLLOWING:

DEFENCE COMMUNICATIONS CABLING STANDARD

DEFENCE COMMUNICATIONS ROOM STANDARD

DEFENCE SERVER ROOM STANDARD

DEFENCE SECURITY PRINCIPLES FRAMEWORK (DSPF)

INFORMATION SECURITY MANUAL (ISM)

CROSSOVER: INSTALL CABLES NEATLY AND WITHOUT CROSSOVERS BETWEEN

CABLES.

LOOM SIZE: LOOM CABLES INTO GROUPS NOT EXCEEDING 50 CABLES, AND HOLD

LOOMS IN PLACE USING REUSABLE VELCRO AT LEAST 20 mm WIDE. DO NOT

EXERT COMPRESSIVE FORCE ON THE CABLES WHEN INSTALLING CABLE

STRAPS. PVC CABLE TIES SHALL NOT BE USED.

TELECOMMUNICATIONS OUTLETS

OUTLETS: PROVIDE RJ45 8 WAY MODULAR JACKS EXCEPT WHERE DOCUMENTED

OTHERWISE.

LABELLING

LABEL BOTH ENDS OF ALL CABLES DURING INSTALLATION.

COMMUNICATION CONDUIT

MINIMUM 2x100mm CONDUIT FOR ANY AREA OF INSTALLATION, PROVIDE MARKER

TAPE ABOVE CONDUIT (PER DCCS REQUIREMENTS). PROVIDE DRAW CHORDS AN

EVERY CONDUIT WITH EYE-BOLT ANCHOR, PER DCCS.

2.9 CABLE SUPPORTS AND DUCT SYSTEM

RESPONSIBILITIES

GENERAL

PROVIDE CABLE SUPPORT, TRUNKING AND DUCT SYSTEMS, AS DOCUMENTED.

PROVIDE FIRE RATED CABLE SUPPORTS FOR LIFE SAFETY SYSTEMS. PROVIDE

TEST CERTIFICATES TO AS/NZS 3013.

CONDUITS

STANDARDS: AS/NZS 2053.1

TYPE: RIGID.

SIZES

CONDUITS: 20 mm.

UNDERGROUND: 25 mm.

CONDUITS FOR TELECOMMUNICATIONS: 25 mm.

FIXINGS

SURFACE MOUNTED: DOUBLE SIDED FIXED.

IN CONCRETE SLABS: TIE TO STRUCTURAL STEEL.

COLOUR

CONDUITS GENERALLY: LIGHT ORANGE.

TELECOMMUNICATIONS SYSTEMS CONDUITS: WHITE.

NON-METALLIC CONDUITS AND FITTINGS

GENERAL

STANDARDS: NON-METALLIC CONDUITS AND FITTINGS: AS/NZS 2053.2, AS/NZS

2053.3, AS/NZS 2053.4, AS/NZS 2053.5 OR AS/NZS 2053.6.

SOLAR RADIATION PROTECTION: REQUIRED FOR CONDUITS AND FITTINGS

EXPOSED TO SUNLIGHT.

FLEXIBLE CONDUIT

GENERAL: PROVIDE FLEXIBLE CONDUIT TO CONNECT WITH EQUIPMENT AND

PLANT SUBJECTED TO VIBRATION. IF REQUIRED, PROVIDE FOR ADJUSTMENT OR

EASE OF MAINTENANCE. PROVIDE THE MINIMUM POSSIBLE LENGTH.

ASSOCIATED FITTINGS

TYPE: PROVIDE ASSOCIATED FITTINGS OF THE SAME TYPE AND MATERIAL AS

THE CONDUIT.

WALL BOXES ON UPVC CONDUITS: PROVIDE PREFABRICATED EARTHED METAL

BOXES, FOR SPECIAL SIZE WALL BOXES NOT AVAILABLE IN UPVC.

INSPECTION FITTINGS

GENERAL: PROVIDE INSPECTION-TYPE FITTINGS ONLY IN ACCESSIBLE

LOCATIONS AND WHERE EXPOSED TO VIEW.

JOINTS

TYPE: CEMENTED OR SNAP-ON JOINTS.

CABLE PITS

GENERAL

CABLE DRAW-IN PITS: PROVIDE CABLE DRAW-IN PITS AS DOCUMENTED. SIZES

GIVEN ARE INTERNAL DIMENSIONS.

COMMUNICATION PITS PER DCCS SIZE REQUIREMENTS.

PROPRIETARY CABLE PITS

PITS 1200 X 1200 mm: PROVIDE PROPRIETARY CONCRETE OR POLYMER

MOULDED PITS.

IN SITU CONSTRUCTION

PITS > 1200 X 1200 mm: PROVIDE EITHER:

PROPRIETARY CABLE PITS.

CONSTRUCT WALLS AND BOTTOMS FROM 75 mm THICK REINFORCED

CONCRETE. INCORPORATE A WATERPROOFING AGENT IN THE RENDER OR

CONCRETE.

PIT COVERS

GENERAL: PROVIDE PIT COVERS TO SUIT EXTERNAL LOADS. FIT FLUSH WITH THE

TOP OF THE PIT.

STANDARD: TO AS 3996.

WEIGHT: < 40 KG FOR ANY SECTION OF THE COVER.

LIFTING HANDLES: PROVIDE A LIFTING HANDLE FOR EACH SIZE OF COVER

SECTION.

DRAINAGE

GENERAL: PROVIDE DRAINAGE FROM THE BOTTOM OF CABLE PITS, EITHER TO

ABSORPTION TRENCHES FILLED WITH RUBBLE OR TO THE STORMWATER

DRAINAGE SYSTEM.

ABSORPTION TRENCHES: MINIMUM SIZE 300 x 300 x 2000 mm.

EXECUTION CONDUIT SYSTEMS - INSTALLATION INSPECTION FITTINGS

LOCATION: LOCATE IN ACCESSIBLE POSITIONS.

DRAW CORDS

GENERAL: PROVIDE 5 mm2 POLYPROPYLENE DRAW CORDS IN CONDUITS NOT IN

USE. ENSURE DRAW CORDS WITHIN COMMUNICATION CONDUITS ARE

ANCHORED WITH EYE-BOLT PER DCCS STANDARDS.

DRAW-IN BOXES

GENERAL: FOR CONDUITS IN ACCESSIBLE LOCATIONS PROVIDE DRAW-IN BOXES

AS FOLLOWS:

IN STRAIGHT RUNS AT > 30m: SPACING 30m.

AT CHANGES OF LEVEL OR DIRECTION.

UNDERGROUND DRAW-IN BOXES: PROVIDE GASKETED COVERS AND SEAL

AGAINST MOISTURE. INSTALL IN ACCESSIBLE PITS.

EXPANSION

GENERAL: ALLOW FOR THERMAL EXPANSION/CONTRACTION OF CONDUITS AND

FITTINGS DUE TO CHANGES IN AMBIENT TEMPERATURE CONDITIONS. PROVIDE

EXPANSION COUPLINGS AS REQUIRED.

RIGID CONDUITS

GENERAL: PROVIDE STRAIGHT LONG RUNS, SMOOTH AND FREE FROM RAGS,

BURRS AND SHARP EDGES. SET CONDUITS TO MINIMISE THE NUMBER OF

FITTINGS.

ROUTES

SET OUT: IF EXPOSED TO VIEW, INSTALL CONDUITS IN PARALLEL RUNS WITH

RIGHT ANGLE CHANGES OF DIRECTION.

BENDS: INSTALL CONDUITS WITH NO MORE THAN 2 RIGHT ANGLED BENDS PER

CABLE DRAW-IN RUN.

CONCEALED CONDUITS: RUN CONDUITS CONCEALED IN WALL CHASES,

EMBEDDED IN FLOOR SLABS OR INSTALLED IN INACCESSIBLE LOCATIONS

DIRECTLY BETWEEN POINTS OF TERMINATION, MINIMISING THE NUMBER OF

SETS. DO NOT PROVIDE INSPECTION FITTINGS. USE LARGE RADIUS BENDS OR

ELBOWS.

CONDUITS IN CONCRETE SLABS

ROUTE: DO NOT RUN IN CONCRETE TOPPINGS. DO NOT RUN WITHIN

PRETENSIONING CABLE ZONES. CROSS PRETENSIONING CABLE ZONES AT

RIGHT ANGLES. ROUTE TO AVOID CROSSOVERS AND MINIMISE THE NUMBER OF

CONDUITS IN ANY LOCATION.

PARALLEL CONDUIT SPACING: 50 mm APART.

CONDUITS IN MECHANICAL PLANT ROOM SLABS: AVOID INSTALLATION OF

CONDUITS IN PLANT ROOM SLABS (BOILER ROOMS, MECHANICAL PLANT ROOMS

AND TANK ROOMS) IF CONDUITS AND CABLES ARE LIKELY TO EXPERIENCE HIGH

TEMPERATURES, BE SUBJECT TO CORE HOLE DRILLING, DRILLING OF LARGE

ANCHOR BOLT POINTS OR WHERE EXACT PLANT LOCATIONS ARE UNKNOWN AT

TIME SLAB IS POURED.

MINIMUM COVER: THE GREATER OF THE CONDUIT DIAMETER AND 20 mm.

CONSTRUCTION JOINTS: PROVIDE SLEEVING OVER CONDUIT TO ALLOW

MOVEMENT OF THE CONDUIT ACROSS THE JOINT DUE TO ANY SLAB

MOVEMENT.

FIXING: FIX DIRECTLY TO THE TOP OF THE BOTTOM LAYER OF REINFORCING.

CONDUITS IN HOLLOW-BLOCK FLOORS

LOCATION: LOCATE CONDUITS IN THE CORE-FILLED SECTIONS OF PRECAST

HOLLOW-BLOCK TYPE FLOORS.

CONDUITS IN COLUMNS

NUMBER AND SIZE OF CONDUITS IN COLUMNS: AS DETERMINED BY THE

STRUCTURAL ENGINEER.

BENDS

ENTER COLUMNS WITH RADIUS SWEEP BENDS GREATER THAN OR

EQUAL TO 150 mm. DO NOT USE ELBOWS.

CHASING

DO NOT CHASE COLUMNS.CABLES IN TRENCHES - INSTALLATION

SAND BED AND SURROUND

GENERAL: CONFORM TO THE SERVICE TRENCHING WORKSECTION.

SAND BED AND SURROUNDS: PROVIDE AT LEAST 150 mm CLEAN SHARP SAND

AROUND CABLES AND CONDUITS INSTALLED UNDERGROUND.

SEALING DUCTS AND CONDUITS

GENERAL: SEAL BURIED ENTRIES TO DUCTS AND CONDUITS WITH WATERPROOF

SEALS AS FOLLOWS:

SPARE DUCTS AND CONDUITS: IMMEDIATELY AFTER INSTALLATION.

OTHER DUCTS AND CONDUITS: AFTER CABLE INSTALLATION.

ALL SURFACES ARE TO BE REINSTATED TO A QUALITY EQUAL TO OR BETTER

THAN EXISTING SURFACE QUALITY.

AI

TA

PE

RO

AD

C

C C C C C C C C C C C C C C

C

C

C C C C C C C C C C C C C C C

C

C

C

C C

C

C2

HM

HM

C C

C

C C C C C

C C

C

C C

C C

C C

C C

C C

C

C C

C C

C C

C

C C

C C

C C

C C

C

C

E C

C

C

C

C C

E

E

E

E

E E

E E

E

E

E

E

E

E

E

E

E

C C

C C

E E

E2

E E2

E

E

E

E

E2

E

E

E

E

E

E2

E2

E

E

E

E E

E E

E E

E

EE

E C

C

C C

C C

C C

C C

C C

C C

C C

C C

C C

C

C

C

C

E

E2E2

E2

E2

E E

C C

C C

C

CE

E

E

C C

C C

C

CE

E C

C C

AI

TA

PE

ROAD

TARAKAN

R O

AD

FU

EL L

IN

E

FU

EL P

IP

E

GIV

No s erv ice s

Brok en

Li d

Bott om

M H 12

9.3

E(HV)

E(HV)

E(H V)

E(H V)

E(H V)

E(H V)

S

S

S

S

W

W

S

Red un da nt?

Red un da nt?

S

S

S

S

IL

.8

S S

S S

Ø

E(LV) E(LV) E(LV) E(LV) E(LV) E(LV)

T

T

T

T

T

T

CS02

CS03

CS04

E-101

SQUADRON OPERATIONS BUILDING

E16929No.

LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV LV

AGLAGLAGLAGLAGLAGLAGLAGL

AGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLL

AGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGLGL

AGLAGLAGLAGLAGLAGLAGLAGL

AG

L

AG

L

AG

L

AG

L

AGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGL

AG

L

AG

L

AG

L

AG

L

AG

L

AG

L

AG

L

AG

L

AGLAGLAGLAGLAGLAGLAGLAGLAGLAGLAGL

AG

L

AG

L

AG

L

AG

L

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C C

C C

C C

C C

C C

C C

C C

C C

C C

C C

C C

C C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C C

C C

C C

C C

C C

C C

C C

C C

C C

C C

C C

C C

C C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C C

C C

C C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

D D D D D D D

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

CCCCCCCCC

DDDDD

D D D D D D D

E

V)

E(HV) E(HV)

E(HV)

E(HV) E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(H V)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(H V)

E(H V)

E(H V)

E(H V)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(H V)

E(H V)

E(H V)

E(H V)

E(H V)

E(H V)

E(H V)

E(H V)

E(H V)

E(H V)

E(H V)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E( H

V) E(

H V)

E( H

V) E(

H V)

E( H

V) E(

H V)

E( H

V) E(

H V)

E( H

V) E(

H V)

E( H

V) E(

H V)

E( H

V) E(

H V)

E( H

V)

E(H V)

E(HV)

E(HV)

E(H V)

E(H V)

E(H V)

E(H V)

E(H V)

E(H V)

E(H V)

E(H V)

E(H V)

E(H V)

E(H V)

E(H V)

E(H V)

E(H V)

E(H V)

E(H V)

E(H V)

E(H V)

E(H V)

E(H V)

E(H V)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(HV)

E(

HV

E(

HV

E(

HV

E(H V)

E(H V)

FI

FI

FI

FI

FU

FU

FU

FU

FU

FU

FU

FU

FU

FU

FU

FU

FU

FU

FU

FU

FU

FU

FU

FU

FU

FU

FU

FU

FU

FU

FU

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S

LV

E(

LV

E(

LV

E(

LV

E(

LV

E(

LV

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E E E

E E

E E

E

W W

W W

W W

W W

W W

W W

W W

W W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

(H V) V

C

H V

E(H

FU

E

E

E

E

E E

E E

E E

E E

E E

E

E

E

C

C C

C C

C C

C C

C

C

C

C

E

C

C C

C C

C C

C C

C C

C C

C C

C C

C C

C C

C C

C C

C

CE

E

E

E

C C

C C

C C

C

CE

E C

C C

E-102

E16929No.

GF-002

GF-003

GF-004

GF-005

GF-008 GF-011

GF-009

GF-010

GF-012

GF-013

GF-006

GF-007

GF-015

GF-016

GF-017

GF-018

GF-019GF-020

GF-021GF-026

GF-022

GF-024

GF-025

GF-027

GF-028

GF-029 GF-030

GF-031

GF-032

GF-023

SE

C

AB

E(

LV

E(

LV

E(

LV

E(

LV

E(

LV

E(

LV

E(

LV

AB

MSB

EWH

3N,63A

ACCU

1N,10A

ACCU

3N,32A

ACCU-5

1N,32A

ACCU

1N,32A

HWU

1N,10A

1N,32A

1N,32A

SEC

1N,10A

1N,32A

MDB

AB

EF

1N,10A

EF

1N,10A

BP

1N,10ABP

1N,10A

ACCU

3N,40A

WPWP

WP

IBT

BUSBAR

(NOTE 12)

EF

1N,10A

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

DB-TEF

E(

LV

E(

LV

E(

LV

E(

LV

E(

LV

E(

LV

E(

LV

AD

TX

ACCU-4

1N,32A

WWP

1N,10A

E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV) E(LV)

FRMW

MSSB-P2

MSSB-P1

MSSB-P3

MSSB-P12

MDB-P8

MDB-P9

MDB-P10

MSSB-P7

DB-TEF-P3

DB-TEF-P2

DB-TEF-P1

MSB-SEC

MSSB-P10

MSSB-P11

MDB-P1

MDB-P2

MDB-P3

MDB-P4

MDB-P5

MDB-P6

MDB-P11

MDB-P12

MDB-P13

MDB-P14

MDB-P15

MDB-P16

MDB-P17

MSSB-P9

MSSB-P6

MSSB-P5

MSSB-P4

MSSB-P13

MSSB-P14

DB-TEF-P4

MDB-P7

MSSB-P17

MDB-P18

DB-TEF-P5

1N,32A

1N,32A

1N,32A

DB-TEF-P7

DB-TEF-P6

DB-TEF-P8

1N,32A

MDB-P19

MDB-PX

NOTE 19

24RU CABINET

FOR DESN

E-111

E16929No.

NOTES

1. DRAWING TO BE READ IN CONJUNCTION WITH ARCHITECTURAL AND OTHER SERVICES DRAWINGS.

2. FINAL LOCATIONS OF ELECTRICAL EQUIPMENT, POWER SUPPLIES AND ISOLATORS SHALL BE DETERMINED ON SITE BY

ELECTRICAL CONTRACTOR IN CO-ORDINATION WITH THE RESPECTIVE TRADE TO SUIT EQUIPMENT AND INSTALLATION CONDITIONS.

3. THE CONTRACTOR SHALL LIAISE WITH THE MECHANICAL, HYDRAULIC, FIRE CONTRACTORS AND THE ARCHITECT TO CONFIRM FINAL LOCATION OF

4. ALL CABLING SYSTEMS SHALL BE INSTALLED ON TENSION WIRE/TRAY, IN FALSE CEILINGS, IN SUITABLE DUCT UNDER BENCHES.

5. ALL POWER OUTLETS SHALL BE LABELLED TO INDICATE TO WHICH DISTRIBUTION BOARD AND CIRCUIT IT IS CONNECTED.

6. POWER CABLE TRAY SHALL BE 600mm. EARTH METALLIC PARTS OF THE CABLE TRAY TO DB EARTH BAR.

7. FLOOR BOX TO BE SUPPLIED VIA 25mm CONDUIT FROM WALL.

8. REFER TO MECHANICAL SPECIFICATION FOR FAN COIL UNITS & POWER CONNECTIONS.

9. SUPPLY POWER TO VAV BOXES. CABLE SHALL BE NO LESS THEN 4mm² PVC.

10. GPOS IN TOLIETS ROOMS TO BE INSTALLED AT COUNTER HEIGHT.

11. PRIMARY BUS BAR TO BE INSTALLED WITHIN DB-TEF. ALL TELLECOMMUNICATIONS DEVICES TO BE CONNECT TO THE THE BONDING BUS BAR.

12. OUTLET SHALL BE ABOVE DOOR FOR POTENTIAL ESS.

13. ALLOW FOR CONDUIT, CABLE AND CONNECTION OF LIGHTNING PROTECTION MASS EARTH INTO MSB MEN SYSTEM.

14. PRESTIGE TYPE GPO SWITCHES TO BE USED FOR THE PWD TOLIET, INSTALLED AT 800 AFFL.

15. SUPPLY POWER TO MECHANICAL CONTROL PANELS FROM MECHANICAL SERVICES SWITCH BOAR.

16. PROVIDE 4x25mm CONDUITS TO FUTURE SECURITY CONTROL PANEL LOCATION. MAKE SUFFICIENT SPATIAL ALLOWANCE FOR TYPE 1A PANEL

TO BE INSTALLED AND COMMERCIAL GRADE ACCESS CONTROL PANEL. CAP OFF CONDUITS.

17. PROVIDE 25mm CONDUIT AND JUNCTION BOXES TO TOP OF DOOR TO ALLOW FOR FUTURE DOOR REED SWITCH. CAP OFF CONDUIT. PROVIDE DRAW ROPE.

18. PROVIDE 2x25mm CONDUIT AND JUNCTION BOXES TO TOP OF DOOR TO ALLOW FOR FUTURE MAGLOCK AND DOOR POSITION SWITCH.

19. POWER CONNECTION FOR HOT WATER RETURN SYSTEM . COORDINATE LOCATION WITH MECHANICAL/HYDRAULIC DESIGN AND INSTALLATION.

20. ALL PENETRATIONS MUST BE APPROPRIATELY SEALED TO MAINTAIN FIRE, ACOUSTIC AND SECURITY RATINGS OF ROOMS.

GF-004

GF-005

GF-008 GF-011

GF-009

GF-010

GF-012

GF-013

GF-006

GF-007

GF-015

GF-016

GF-017

GF-018

GF-019GF-020

GF-021GF-026

GF-022

GF-024

GF-025

GF-027

GF-028

GF-029 GF-030

GF-031

GF-032

GF-023

MSB

MDB

2 2 2 2

CT1CT1CT1CT1CT1CT1CT1CT1CT1CT1CT1CT1CT1CT1CT1CT1CT1CT1CT1CT1CT1CT1

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

1 CT2CT2CT2CT2CT2CT2CT2CT2CT2CT2CT2CT2CT2CT2CT2CT2CT2CT2CT2CT2CT2CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT2CT2CT2CT2CT2CT2CT2CT2

CT3CT3CT3CT3CT3CT3CT3CT3

CT

CT

CT

CT

CT3CT3CT3CT3CT3CT3

CT2CT2CT2CT2CT2

CT

CT

CT

CT

CT

CT

CT3CT3CT3CT3CT3CT3CT3CT3CT3CT3

CT2CT2CT2CT2CT2CT2CT2CT2CT2CT2 CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT3

CT2

CT3

CT2

CT3

CT2

CT3

CT2

CT3

CT2

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

E(

LV

E(

LV

E(

LV

E(

LV

E(

LV

E(

LV

E(

LV

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

E(

LV

E(

LV

E(

LV

E(

LV

E(

LV

E(

LV

E(

LV

DB-TEF

CT

CT

CT3CT3CT3CT3

CT2 CT2 CT2CT2CT2

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

2 2

(NOTE 14)

CT4CT4CT4

CT4CT4CT4CT4CT4CT4CT4CT4CT4CT4CT4CT4CT4CT4CT4CT4CT4

CT4CT4CT4CT4CT4CT4CT4CT4CT4CT4CT4CT4

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

CT

S

S

S

S

S S

S S

S S

S S

S

S S

S S

S S

S S

S S

S

S S

S S S S S

SS

S S

S S

S S

S S

S S

S S

S S

S

S

(NOTE 2)(NOTE 2)

(NOTE 2)(NOTE 2)

(NOTE 1)

(NOTE 1)

(NOTE 1)

(NOTE 1)

(NOTE 1)

(NOTE 1)

(NOTE 1)

(NOTE 1).

(NOTE 1) (NOTE 1)

(NOTE 1)

(NOTE 3)

(NOTE 1)

24RU CABINET

FOR DESN

E-121

E16929No.

NOTES

1. 25mm COMMUNICATIONS CONDUIT CONCEALED WITHIN THE WALL CAVITY FROM CABLE TRAY IN CEILING TO TERMINATE AT 150mm SQUARE JUNCTION BOX AT 1000mm ABOVE FGL. ENSURE

JUNCTION BOX JOINT IS TIGHT AND SECURE WITHIN WALL AND DOES NOT PROTRUDE BEYOND FINISHED SURFACE. PROVIDE FLAT BLANK COVER PLATE WITH TAMPER RESISTANT SCREWS.

2. 25mm COMMUNICATIONS CONDUIT FROM CEILING MOUNTED CABLE TRAY TO CEILING POINTS AS SHOWN ON DRAWING.

3. 2 X 50mm COMMUNICATIONS CONDUIT CONCEALED WITHIN THE WALL CAVITY FROM CEILING MOUNTED CABLE TRAY TO 1000mm ABOVE FG.

4. SECURE AND UNSECURED COMMUNICATIONS CABLE TRAY SHALL BE AT LEAST 300mm APART. SPACE AND SIZE OF CABLE TRAYS ON DRAWING INDICATIVE ONLY.

5. CABLE ACCESS BETWEEN SECURE AND UNSECURED ZONES SHALL BE VIA SEALED CONDUIT RACEWAY THROUGH THE SECURE WALL.

6. PAIRS OF DOUBLE DATA OUTLETS SHALL BE SPLIT BETWEEN USAF UNSECURED AND SECURED WITHIN THE SECURE ZONE. REFER TO BLOCK DIAGRAM ON E-603.

7. PAIRS OF DOUBLE DATA OUTLETS SHALL BE SPLIT BETWEEN USAF UNSECURED AND AUS DPN WITHIN THE UNSECURED ZONE. REFER TO BLOCK DIAGRAM ON E-603.

8. CABLE TRAYS SHALL BE 300mm ENSURE CABLE TRAYS HAVE 50% SPARE CAPACITY. EARTH METALLIC PARTS OF CABLE TRAY TO DB EARTH BAR.

9. CONTRACTOR SHALL FOLLOW THE COMMUNICATIONS CABLING REQUIREMENTS APPLICABLE SECURITY STANDARD FOR AUSTRALIAN DEFENCE (COLOURS PER AUS DEFENCE REQUIREMENTS).

10. AUSTRALIAN RACK SHALL BE A CLASS - C CABINET.

11. COMMUNICATION CABLING WITHIN BUILDING SHALL BE INSTALLED ON THE DESCRIBED CABLE TRAY OR WITHIN CONDUIT

12. FLOOR BOXES SHALL BE SUITABLE FOR ZONE 2 SECURITY. BUT UPGRADEABLE TO ZONE 4 IN THE FUTURE.

13. OUTLET LABELS SHALL BE PER DCCS STANDARDS.

14. ONE QUAD DATA OUTLET SHALL BE CONNECTED TO USAF UNSECURED AND SECURED RACKS.

15. CIOG DEFENCE SHALL HAVE ACCESS TO COMMUNICATIONS ROOM. COORDINATE ROOM ACCESS WITH CIOG.

16. CONTINUOUS CONDUITS SHALL RUN FROM POWER AND COMMUNICATION OUTLETS ALL THE WAY TO CABLE TRAY.

17. 24RU WALL MOUNTED CABINET FOR BUILDING DESN, BMS AND FIP EQUIPMENT. CABINET SHALL BE CONNECTED TO WIDER SITE. EQUIVALENT TO STARTECH RK630WALVS.

18. PROVIDE 100mm RACEWAY CHASE PENETRATION THROUGH WALL FOR COMMUNICATIONS CABLES. CHASE SHALL EXTENDED BEYOND WALL SURFACE MINIMUM 300mm ON EACH SIDE.

GF-004

GF-005

GF-008 GF-011

GF-009

GF-010

GF-012

GF-013

GF-006

GF-007

GF-015

GF-016

GF-017

GF-018

GF-019GF-020

GF-021GF-026

GF-022

GF-024

GF-025

GF-027

GF-028

GF-029 GF-030

GF-031

GF-032

GF-023

FDCIE TO BE RECESSEDFFFFFFFFFDDDDDDDDDDDDCCCCCCCCCCCCIIIEEEEEEEEEEE TTTTTTTTTTTOOOOOOOOOOOOOO BBBBBBBBBBBEEEEEEEEEE RRRRRRRRRRRREEEEEEEEEECCCCCCCCCCCCCEEEEEEEEEEESSSSSSSSSSSSSSSSSSSSSSSSEEEEEEEEEEEDDDDDDDDDDDD

L1 L1 L1L1 L1 L1L1L1

L1L

L1

L1

L1L1L1L1

L11

L1L1

L1 L1

L11

L1

L1

L1L

L1L1

L1

L1 L1 L1 L1 L1 L1L1

L1

L1LL1

L1 L1

L1 L1

L1

L1 L1

L1L1

L1 L1

L1

L1

L1

L1 L1

L1L1

L1 L1

L1LL

L1

L1 L1

L1L1 L1

L1 L1

L1 L1L1

L1

L1 L1

L1

L1

L1 L1

L1

L1

L1L1

L1

L1

L1 L1

L1

L1 L1

L1

L1 L1L1

L1

L1L1

L1

L1L1

L1 L1 L1

L1LL1L1L1

L1 L1

L2 L2L2 L2

L2

L2

L2L2

L2

W1

W1W1W1

W1

W1

W1

W1

W1

W1 W1 W1 W1 W1 W1

W1

W1

W1

W1111111WWWWWWWWWWWWWWWWWW

W1

W1

W1

D100 D1D1D11D1

D1 D1 D1DDDDDDDDD D1D11111

D1D1 D1

D1D D1DD1

D1D1 D1D1D1D1

D1D D1

D1

L1

D1 D1

D1D1D1

DS

L1

D1 D1 D1 D1 D1

DDGG

D1D1

L2

W1

L3L3L3L3L3LL3

MDB-L1

MDB-L2

MDB-L3

MDB-L4

MDB-L5

MDB-L6

MDB-L7

MDB-L8

MDB-L9

MDB-L10

L2

L2L2L2

L2 L2 L2

L2

L2

E-131

E16929No.

NOTES

1. PROVIDE ALL LUMINARIES COMPLETE WITH LAMPS AND ACCESSORIES AS SPECIFIED.

2. EMERGENCY EVACUATION LIGHTING SYSTEM TO MEET THE REQUIREMENTS OF THE BCA. TEST AND COMMISSION IN CONFORMANCE WITH AS/NZS 2293.

3. COORDINATE HEIGHT OF SWITCHES WITH ARCHITECTURAL EQUIPMENT SCHEDULES.

4. COORDINATE LIGHTING LAYOUT WITH CEILING GRID. REFER TO ARCHITECTURE SPECIFICATIONS AND DRAWINGS.

5. REAR BLOCKING BEHIND CLADDING IS REQUIRED WHERE EXTERNAL LIGHTING SHALL BE INSTALLED. REFER TO ARCHITECTURAL DRAWINGS FOR EXTERNAL LIGHT FITTING HEIGHTS. NOMINALLY

2500AFFL.

E E

E

E

E

EEE

P1

P2

P1

P1P1

P1 P1

W W

W

W W

W

WW

S

S S

HM

HM

C C

C

C C C C C

C C

C C

C C

C C

C C

C C

C C

C C

C C

C C

C

E C

C

C C

E

C C

C

E

E

E2

E

E

E

E E

E E

E E

E

EE

E2E2

E2

E2

E-132

SQUADRON OPERATIONS BUILDING

E16929No.

GF-004

GF-005

GF-008 GF-011

GF-009

GF-010

GF-012

GF-013

GF-006

GF-007

GF-015

GF-016

GF-017

GF-018

GF-019GF-020

GF-021GF-026

GF-022

GF-024

GF-025

GF-027

GF-028

GF-029 GF-030

GF-031

GF-032

GF-023

GF-002

GF-003

GF-004

GF-005

GF-008 GF-011

GF-009

GF-010

GF-012

GF-013

GF-006

GF-007

GF-015

GF-016

GF-017

GF-018

GF-019GF-020

GF-021GF-026

GF-022

GF-024

GF-025

GF-027

GF-028

GF-029 GF-030

GF-031

GF-032

GF-023

320 LUX

320 LUX

320 LUX

320 LUX

320 LUX

320 LUX

320 LUX

320 LUX

400 LUX

400 LUX

240 LUX

240 LUX

240 LUX

240 LUX

240 LUX

240 LUX240 LUX

240 LUX

240 LUX

240 LUX

240 LUX

240 LUX

240 LUX

240 LUX

240 LUX

160 LUX

160 LUX

160 LUX

160 LUX

160 LUX

160 LUX

160 LUX

160 LUX

160 LUX

320 LUX

320 LUX

320 LUX

240 LUX

320 LUX

320 LUX

240 LUX

E-141

E16929No.

32 LUX

32 LUX

32 LUX

32 LUX

32 LUX

32 LUX

32 LUX

32 LUX

7 LUX

7 LUX

7 LUX

7 LUX

7 LUX

7 LUX

7 LUX

7 LUX

7 LUX

7 LUX

7 LUX

7 LUX

1.5 LUX1.5 LUX

7 LUX

1.5 LUX

1.5 LUX

1.5 LUX

7 LUX

1.5 LUX

7 LUX

7 LUX

7 LUX

7 LUX

E-142

SQUADRON OPERATIONS BUILDING

E16929No.

E-151

E16929No.

1. LIGHTNING PROTECTION SHALL BE INSTALLED PER AS/NZS 1768 AND AS 4262

2. ALL CONDUCTORS AND EARTH ELECTRODES TO BE SIZED AND SPACED PER AS 1768

3. EARTH RING SHALL HAVE A NOMINAL DEPTH OF 400mm AND A NOMINAL OFFSET FROM THE BUILDING OF 400mm

4. EARTHING RESISTANCE SHOULD NOT EXCEED 10ohms PER AS 1768.

5. TEST LINKS SHALL BE PROVIDED FOR EACH INDIVIDUAL PARALLEL PATH OF THE LIGHTNING CONDUCTOR SYSTEM. TEST LINKS ARE TO BE SECURED IN

THE CLOSED POSITION AND ARRANGE SO WHEN OPENED IT DOES NOT INTERFERE WITH THE REST OF THE SYSTEM PER AS 1768.

6. EARTHING RING SHALL BE CONNECTED INTO THE MSB M.E.N BUS BAR.

7. DOWN CONDUCTORS TO BE EXPOSED ON FACE OF BUILDING. AIR TERMINAL CONDUCTOR SHALL CONNECT TO ELECTRODE IN EARTH PT VS EARTH

RING.

8. AIR TERMINALS SHALL NOT EXCEED 600mm FROM OUTSIDE EDGE OF ROOF

EXIT FLAPDESK CUTOUT

& LID

DESK FLY LEADS TO EQUIPMENT

PLATE

POWER CUTTERS

GROMMETS

FLOOR WEIGHT

SWITCHED SOCKET OUTLET

OR STARTER SOCKET

CONDUITS CAST IN SLAB SEPARATE

FOR POWER, COMMS

HOUSING

PHYSICAL BARRIERS FOR AV, DATA

& POWER SECTION RESPECTIVELY

CONDUITS CAST IN SLAB SEPARATE

FOR POWER, COMMS

SLAB

OUTLETS

PLATE

RECESSED IN LID

FOR CARPET

FLOOR

WEIGHT

DATA, AV & SECURITY

EQUIPMENT

BARRIER

HOUSING

CORNER VIEW

FLAT VIEW

FINISHED GRADE

CONCRETE LID

EARTH ROD PIT (NOTE 6)

NATIVE SOIL OR

COMPACTED BACKFILL

CONCRETE

DUCTILE IRON PIPE

MIN. INSIDE

BRICK LEVELING COURSE

PRIMARY LIGHTNING PROTECTION

CONDUCTOR RUN ALONG ROOF EDGE.

POINT AND POINT BASE (INCLUDING

CABLE HOLD DOWN CLAMPS)

SECURED TO ROOF PANEL WITH

SILICON ADHESIVE/SEALANT RATED

FOR HIGH TEMPERATURE, UV/OZONE

RESISTANCE, AND NO CORROSIVE.

PRIMARY LIGHTNING PROTECTION

EQUALIZATION CONDUCTOR.

ROOF SYSTEM.

(NOTE 5).

PROVIDE ORANGE ORNAMENTAL

BALL ON ALL TERMINALS MARKED "A".

BI-DIRECTION BOND 35mm² INSULTED

STRANDED COPPER CONDUCTOR

CABLE SUPPORT

SEE DETAIL

COMPRESSION "C-TAP"

(TYPICAL)

BI-DIRECTION BOND 35mm² INSULTED

STRANDED COPPER CONDUCTOR

BI-DIRECTION BOND 35mm²

INSULTED STRANDED

COPPER CONDUCTOR

200 x 200

900 x 900 SQUARE

GROUND CONDUCTOR 12mm DIAMETER COPPER CLAD STEEL, 1500mm LONG

MINIMUM COVER

TO CONDUITS

MARKER TAPES

ELECTRICAL/COMMS CONDUITS AS NOTED

STONE FREE SAND FILL. MINIMUM

50mm COVER ABOVE AND BELOW60

BACKFILL

MI

N

0m m

EARTH RING SOLID TIN BARE

CONDUCTOR Cu 70mm²

CABLING PIT

INCOMING CONDUITS

MARKING TAPE

FLOOR LEVEL

CABLE PIT DETAIL ADJACENT TO THE BUILDING WITH CONDUITS RUNNING UNDER FOOTINGS

CONCRETE REINFORCING

COLLAR TO ALL PITS

ENSURE ALL CONDUIT ENTRIES ARE MIN. 50mm

INSIDE PIT & ARE FREE OF BURRS & SHARP EDGES.

CONDUIT SHALL ENTER 300mm ABOVE BASE OF PIT.

CONDUIT TO FINISH 100mm

AFL WITH APPROVED SEALANT

(VERMIN PROOF).

APPROVED TERMITE BARRIER

SYSTEMPIPE COLLAR

PER AS 3660.

SCEC APPROVED PIT AND

PIT LED. VERMIN AND

SNAKE PROOF

REFER TO STRUCTURAL SET

FOR EXTERNAL BLOCK WALL

DETAIL. COORDINATE

CONDUIT INSTALLATION WITH

STRUCTURAL AND CIVIL.

E-501

E16929No.

NOTES

1. POWER AND COMMUNICATION PITS SHALL BE

ENTIRELY CLASS D. INCLUDING THE PIT LID AND SCEC

APPROVED.

2. REFER TO STRUCTURAL DRAWINGS FOR CONDUIT

RETICULATION AND SLAB COORDINATION FOR FLOOR

BOXES.

3. LIGHTNING PROTECTION AIR TERMINAL SHALL BE

POINTED WITH A NOMINAL DIAMETER OF 14mm WITH

M16 THREAD. MATERIAL SHALL BE COPPER. AIR

TERMINAL SHALL BE APPROPRIATELY FIXED TO DOWN

CONDUCTOR VIA TERMINAL BASE. DOWN CONDUCTOR

SHALL BE STRANDED Cu 35mm² HELD TO EXTERIOR

WALL BY CLAMPS WITH NO MORE THAN 1M SPACING.

4. AIR TERMINAL CONDUCTOR SHALL BE STRANDED

35mm2 AND HELD DOWN TO ROOF VIA HOLD DOWN

CLAMPS. CABLE SHALL RUN ALONG ROOF VIA AIR

TERMINALS AS SHOWN IN E-151.

5. 300mm X 300mm ROOFING PANEL SUPPLIED BY

ROOFING CONTRACTOR. SECURE ROOF PANEL TO

ROOF SYSTEM WITH ADHESIVE SUPPLIED BY ROOFING

CONTRACTOR AND UNDER THEIR DIRECTION. SECURE

POINT BASE/CABLE CLIP TO ROOFING LABEL WITH

SILICON ADHESIVE. DO NOT PUNCTURE ROOFING

SYSTEM.

6. EARTH ROD PIT WITH DIMENSIONS 200 x 200 x 150mm

WITH CONCRETE LID AND SHALL INCLUDE ALL

NECESSARY BONDING AND CONNECTING EQUIPMENT,

EARTH BAR, DISCONNECTING LINKS ETC.

7. CABLE TRAY SHALL BE OF BASKET TYPE WHEN

CARRYING COMMUNICATION CABLING. CABLE TRAY

SHALL BE OF LADDER TYPE WHEN CARRYING POWER

CABLING.

8. ALL HOLES FOR ELECTRICAL SERVICES MUST BE CUT

OR DRILLED, NOT PUNCHED.

9. ALL GAPS SEALED WITH A SUITABLE NON-HARDENING

MASTICS SEALANT (BOSTIK FIRE BAN 1 OR RAMSET

BLAZEBRAKE).

10. ALL BUILDING PENETRATIONS FROM INCOMING PITS

ARE AS PER DCCS.PARA.53-I, A MINIMUM OF 100MM

INSIDE-DIAMETER GALVANISED IRON PLATED CONDUIT

FOR ALL BUILDING PENETRATIONS.

11. COMMUNICATION PITS TO CONFIRM TO DCCS

REQUIREMENTS. ENSURE APPROPRIATE DRAINAGE

FOR ALL PITS, INTO ROCK BEDS UNDERNEATH.

CABLE TRAY

UNDERSIDE OF SLAB

IBS FOAM ROD WEDGED IN.

SEALED WITH A SUITABLE

NON-HARDENING MASTICS

SEALANT. BOTH SIDES. NO GAP

GREATER THAN 12mm.

IBS FOAM ROD WEDGED IN.

SEALED WITH A SUITABLE

NON-HARDENING MASTICS

SEALANT. BOTH SIDES. NO GAP

GREATER THAN 12mm.

Ø50mm STEEL CONDUIT

MAX.

GAP INSIDE THE CONDUIT CAN

EITHER BE PACKED WITH

INSULATION (TO ALLOW FUTURE

CABLE RETICULATION) OR

SEALED WITH MASTIC. BOTH

SIDES.

BUNCHED CABLES

PIPE/CONDUIT

IF THE GAP AROUND CONDUIT/PIPE

IS LESS THAN 20mm, USE A

BACKING ROD THEN SEAL WITH

RESILIENT, NON HARDENING

MASTIC TO A DEPTH OF 20mm, BOTH AT THE BOTTOM AND TOP OF

THE SLAB. IF THERE IS A LARGE

PENETRATION WHICH MAY BE

IRREGULAR THEN YOU CAN EITHER

FILL THE CAVITY WITH GROUT OR

YOU CAN PACK THE CAVITY WITH

POLYESTER INSULATION, THEN

TWO SHEETS OF PLASTERBOARD

OR 6mm FIBROUS CEMENT SHEET

SHOULD BE FIXED TO THE SLAB TO

FORM A SOUND RESISTANT SEAL.

SLAB

PIPE/CONDUIT

COLLAR INSTALL TO

MANUFACTURERS

SPECIFICATION. TO SUIT

PIPE/CONDUIT

IF GAP BETWEEN

PIPE/CONDUIT & CORED HOLE

IS GREATER THAN 12mm, BACKFILL WITH MORTAR , FOR

GAPS LESS THAN 12mm SEAL

WITH APPROPRIATE SEALANT

MAIN SWITCH BOARD (MSB) (G1115 / 1)

OCCUPIED

SERVICES

MAIN SWITCH

125A

200A MINIMUM

FORM 2b TO AS61439.1

MIN. POLES 48 POLES ON EACH BUS BAR

MIN. FAULT LEVEL 20kA (TBC BASE TINDAL ELEC)

IP42 TO AS60529

MIN. BUS SIZE 250A

PRIVATE METERM

SURGE DIVERTER

E

MEN

LINK

N

UNOCCUPIED

SERVICES MAIN

SWITCH

150A

200A MINIMUM

MDB

UNOCCUPIED SERVICE

SECTION

MAIN

SWITCH

250A

10A

SECURITY

CONTROL

PANEL

SEC

63A

DB-TEF

30%

SPARES

MECHANICAL

SERVICES

SWITCHBOARD

(MSSB)

125A 150A

63A

OCCUPIED SERVICE

SECTION

SPARE

250A

415V 415V

415V

METER SHALL

INTERFACE WITH SITE

BMS AND PCMS

10A

20A

3kVA 230/120V

US-STYLE

NEMA

5-20

DUPLEX

OUTLET

SS35

NO. CABLE SCHEDULE

185mm² Cu XLPE 4x1C

70mm² Cu WS52W 4C + E

16mm² Cu WS52W 4C + E

16mm² Cu XLPE 4C + E

6mm² Cu WS52W 2C + E

235 4

E-601

E16929No.

GENERAL SHEET NOTES

1. SWITCHBOARD AND CABLING SHALL COMPLY WITH THE

REQUIREMENTS OF AS/NZS 3000 AND AS/NZS 61439.1

2. ALL SWITCHGEAR EQUIPMENT ARE TO BE THE SAME

MANUFACTURER TO PROVIDE ENHANCED PROTECTION.

3. PROTECTION SETTINGS TO GRADE WITH SUPPLY SUBSTATION

PROTECTION. PROVIDE FINAL GRADING STUDY FOR APPROVAL.

4. SURGE DIVERTERS SHALL BE SIZED ACCORDING TO AS/NZS

3000, TYPICALLY 100 kA PER PHASE FOR AN 8/20uS IMPULSE.

SURGE DIVERTER SHALL BE PROTECTED IN ACCORDANCE WITH

MANUFACTURER RECOMMENDATION.

5. PRIVATE MULTIFUNCTION METERS ARE TO BE CLASS 2

ACCURACY AND PROVIDE ENERGY, VOLTAGE, MAXIMUM

DEMAND AND POWER FACTOR DATA. ALL METERS MUST MATCH

MIEE AND THE NATIONAL SUB-METER PROGRAM

REQUIREMENTS.

6. PROVIDE CIRCUIT BREAKER SPACE FOR FUTURE UPGRADES.

7. M.E.N SYSTEM TO BE BONDED IN ACCORDANCE WITH AS/NZS

3000.

8. MINIMUM LIGHTING SUB-CIRCUITS SHALL BE 2.5mm². MINIMUM POWER SUB-CIRCUITS SHALL BE 4mm².

9. LIGHTNING PROTECTION EARTH SYSTEM SHALL BE CONNECTED

INTO THE MEN VIA MAIN EARTH PIT.

10. ALL METERS SHALL BE OF THE SMART TYPE AND CONNECTED

INTO THE SITE MONITORING VIA THE TEF ROOM.

11. CONNECT TO EXISTING SPARE CIRCUIT BREAKER POSITION.

COORDINATE SHUT-DOWN OF SUBSTATION TO MAKE

CONNECTION WITH SITE.

12. PROVIDE A 3kVA STEP DOWN TRANSFORMER 230V/120V

LOCATED IN THE ELECTRICAL ROOM. THE TRANSFORMERS

SECONDARY SIDE SHALL HAVE A 20A CIRCUIT BREAKER WHICH

FEEDS A USA STYLE NEMA 5-20 DUPLEX OUTLET LOCATED AT

THE STATCOM PAD.

13. PROVIDE 300H x 400W 12 POLE ENCLOSURE TO HOUSE

TRANSFORMER SECONDARY CIRCUIT BREAKER. CIRCUIT

BREAKER TO BE NEMA APPROVED.

MAIN DISTRIBUTION BOARD (MDB) - SINGLE LINE DIAGRAM

NOT TO SCALE

(MDB)

MAIN DISTRIBUTION BOARD

G1115/1.1

SURGE DIVERTER

FORM 2 TO AS61439.1

IP42 TO AS60529

SUPPLY FROM MSB

20A20A

MAIN SWITCH

100A

P2 - OFFICE AMU

P12 - OPS DESK

MIN. FAULT LEVEL 10kVA

MIN. POLES 48

MIN. BUS RATING 200A

P6 - FLOOR BOXES

P8 - HWU

P10 - FRIDGE

P1 - AMU ADMIN

P3 - LSE

P5 - MISSION PLANNING

P7 - CREW MEETINGS & MISSION PLANNING

P9 - MICROWAVE

P11 - TOILETS & BREAK ROOM

P14 - MASS BRIEFINGP13 - OPS OFFICES

P4 - CREW MEETING

P16 - MASS BRIEFINGP15 - DUTY OFFICER

COMMUNICATIONS DISTRIBUTION BOARD (DB-TEF) - SINGLE LINE DIAGRAM

NOT TO SCALE

(DB-TE)

COMMUNICATIONS DISTRIBUTION BOARD

G1115/1.2

SURGE DIVERTER

FORM 2 TO AS61439.1

IP42 TO AS60529

SUPPLY FROM MSB

MAIN SWITCH

63A

P2 - COMMUNICATIONS

MIN. FAULT LEVEL 10kVA

MIN. POLES 24

MIN. BUS RATING 200A

P1 - COMMUNICATIONS

MECHANICAL SERVICES SWITCHBOARD (MSSB) - SINGLE LINE DIAGRAM

NOT TO SCALE

(MSSB)

MECHANICAL SERVICES SWITCHBOARD

G1115/1.3

SURGE DIVERTER

FORM 2 TO AS61439.1

IP42 TO AS60529

SUPPLY FROM MSB

40A40A

10A

10A

10A

10A

32A

MAIN SWITCH

150A

M DIGITAL CURRENT METER

P2 - DEDICATED OUTDOOR AIR SYSTEM 1

40A

P12 - INSTANTANEOUS WATER HEATER

MIN. FAULT LEVEL 10kVA

MIN. POLES 36

MIN. BUS RATING 200A

10A

10A

P6 - EXHAUST FAN

32A

P8 - AIR HANDLING UNIT 1

32A

P10 - AIR COOLED CONDENSER UNIT 3

P1 - AIR COOLED CONDENSER UNIT 1

P3 - AIR COOLED CONDENSER UNIT 2

P5 - BOOSTER PUMP

P7 - EXHAUST FAN

P9 - EXHAUST FAN

P11 - AIR COOLED CONDENSER UNIT 4

P4 - BOOSTER PUMP

20A20A

20A20A

20A20A

20A20A

20A20A

20A20A

20A20A

32A

32A32A

P17 - ELECTRICAL ROOM

20A

P17 - AIR COOLED CONDENSER UNIT 5

P4 - COMMUNICATIONS

16A 16A

P14 - MAINTENANCE GPOSP13 - MAINTENANCE GPOS

16A 16A

P16 - VAV BOXES (NOTE 12)(NOTE 12) P15 - VAV BOXES

NO. CABLE SCHEDULE

10mm² Cu WS52W XLPE

16mm² Cu WS52W XLPE 4C+E

6mm² Cu WS52W XLPE 4C+E

10mm² Cu XLPE

SPARE

(NOTE 4)

(NOTE 4)

(NOTE 4)

10A

16A16A

16A

16A

16A

16A

L2 - CARPARK LIGHTING

16A

L4 - CREW MEETING & TEF/COMMS ROOM

16A

L6 - BREAK ROOM & MECHANICAL ROOM

16A

L8 - OPS DESK, OPS OFFICES & HALLWAY

16A

L10 - DUTY OFFICER & HALLWAY

L1 - EXTERNAL LIGHTING

L5 - MISSION PLANNING & CREW MEETING

L7 - TOILETS

L9 - MASS BRIEFING

SPARE

SPARE

SPARE

L3 - AMU ADMIN, OFICE AMU, LSE & ELECTRICAL ROOM

M DIGITAL CURRENT METER

M DIGITAL CURRENT METER

32A

SPARE

P18 - WASTE WATER PUMP

SPARESPARE

SPARESPARE

SPARESPARE

10A

P18 - DDC

10A

P20 - ACCU-1/AHU-1 CONTROL PANEL

10A

P19 - DOAS-1 CONTROL PANEL

P5 - DESN / FIP RACK

32A

RACK 1 (USAF)

P3 - COMMUNICATIONS

RACK 1 (AUS)

RACK 2 (USAF)

ROOM GPOS

SPARE

SPARE

& TEF/COMMS ROOM

LCR1

16A

L11 - PATHWAY LIGHTING

LCR1

ELCREMERGENCY LIGHTING

ELCREMERGENCY LIGHTING

ELCREMERGENCY LIGHTING

ELCREMERGENCY LIGHTING

ELCR EMERGENCY LIGHTING

ELCR EMERGENCY LIGHTING

ELCR EMERGENCY LIGHTING

ELCR EMERGENCY LIGHTING

LCR1

16A

32A

32A 32A

32A 32A

P7 - COMMUNICATIONS

RACK 1 (USAF)

P8 - COMMUNICATIONS

RACK 1 (AUS)

P6 - COMMUNICATIONS1

RACK 2 (USAF)

SPARE

P19 - GPO FOR FUTURE

SECURITY EQUIPMENT

20A

MIN. 25% SPARE POLE CAPACITY

MIN. 25% SPARE POLE CAPACITY

MIN. 25% SPARE POLE CAPACITY

E-602

E16929No.

NOTES

1. SWITCHBOARD AND CABLING SHALL COMPLY WITH THE

REQUIREMENTS OF AS/NZS 3000 AND AS/NZS 61439.1

2. ALL SWITCHGEAR EQUIPMENT ARE TO BE THE SAME

MANUFACTURER TO PROVIDE ENHANCED PROTECTION.

3. PROTECTION SETTINGS TO GRADE WITH SUPPLY SUBSTATION

PROTECTION. PROVIDE FINAL GRADING STUDY FOR APPROVAL.

4. SURGE DIVERTERS SHALL BE SIZED ACCORDING TO AS/NZS

3000, TYPICALLY 100 kA PER PHASE FOR AN 8/20uS IMPULSE.

SURGE DIVERTER SHALL BE PROTECTED IN ACCORDANCE WITH

MANUFACTURER RECOMMENDATION.

5. PRIVATE MULTIFUNCTION METERS ARE TO BE CLASS 2

ACCURACY AND PROVIDE ENERGY, VOLTAGE, MAXIMUM

DEMAND AND POWER FACTOR DATA.

6. PROVIDE 25% SPARE POLES FOR CIRCUIT BREAKERS FOR

FUTURE UPGRADES.

7. PROVIDE IES RECIPROCALS TO COMMUNICATIONS RACK. WITH

RACK EQUIPMENT AND RACK UPS TO BE PROVIDED BY OTHERS.

8. ENSURE LOADS ARE BALLANCED ACROSS ALL PHASES.

9. REFER TO MECHANICAL FUNCTION SPECIFICATION FOR DETAILS

ON MECHANICAL SERVICES SWITCHBOARD.

10. ALL METERS SHALL BE OF THE SMART TYPE AND CONNECTED

INTO THE SITE MONITORING VIA THE TEF ROOM.

11. UNLESS SPECIFIED CABLE SIZE TO BE 2.5mm² PVC FOR SINGLE

PHASE CIRCUITS.

12. COORDINATE WITH MECHANICAL DESIGN AND INSTALLER FOR

LOCATION OF VAV BOXES. SPLIT POWER SUPPLY TO VAV BOXES

BETWEEN P15 & P16 USING 2.5mm2 2C+E.

TYPICAL VAV POWER CIRCUIT

NO SCALE

CB 'A'

16A

CB 'A' VAV BOX

LOCAL VAV SWITCH

(INSTALLED NEAR VAV BOX)

EMERGENCY LIGHTING ACTIVATION & TEST CIRCUIT TO AS2293

NOT TO SCALE

PART DB

6A CONTROL

RESET TEST

T1.1

T1

TIMER

RESET

0-180 min

SET TO 120

N

ELCR

AC3

NC

EM

L1

EM

L2

EM

L3

L2 L3

LIGHT

CONTROL

RELAY

No.1

EXTERNAL

LIGHTING

TYPICAL LIGHTING CONTROL DIAGRAM

NOT TO SCALE

TYPICAL PIR CIRCUIT DETAIL

NOT TO SCALE

30mA

PIR

SENSOR

230V

LIGHTING CIRCUIT

(LUMINAIRES)

PIR

No. OF PIR'S TO SUIT

LIGHTING CIRCUIT.

16A

24Hr

TIMER

N

PE CELL

PER

PE

16A 30mA

LCR1

PER/1

T1

T1/1

AUTO ON

OFF

TIMER

LIGHTING CONTROL

PURPOSE TIME 'ON' CONTROL 'OFF' CONTROL

- INTERNAL LIGHTING BUSINESS HOURS PIR MOTION SENSORS RUN TIME 30MIN (ADJUSTABLE)

- INTERNAL LIGHTING BUSINESS HOURS LOCAL SWITCHING BY CONTACTOR WITH FSE

OVERRIDE LOCAL SWITCHING BY CONTACTOR WITH FSE OVERRIDE

- PATHWAY - LOCAL SWITCHING BY CONTACTOR WITH FSE

OVERRIDE LOCAL SWITCHING BY CONTACTOR WITH FSE OVERRIDE

- BUILDING PERIMETER

LIGHTING DUSK-DAWN PE CELL AND TIMING CIRCUIT OVER-RIDE ON & OFF SWITCHES

- CARPARK LIGHTING DUSK-DAWN PE CELL AND TIMING CIRCUIT OVER-RIDE ON & OFF SWITCHES

** ALL TIME-SWITCHES TO BE 7-DAY PROGRAMMABLE TYPE (MIN 4 CHANNEL) WITH 100 HOURS BATTERY RESERVE PROGRAMMED TO SUIT CLIENT REQUIREMENTS. WHERE TIMES ARE SUGGESTED IN THE TABLE ABOVE, THEY ARE ONLY INDICATIVE AND FINAL OPERATION HOURS ARE TO BE CONFIRMED WITH THE CLIENT AND PROGRAMMED TO

SUIT THEIR REQUIREMENTS.

USAF

RACK 1

SECURE

USAF

RACK 2

UNSECURE

AUS

RACK 3

DPN

TYPICAL

DATA

OUTLETS

SECURED AREA

UNSECURED AREA

TO SATELLITE

PAD

TO SATELLITE

PAD

TELECOMMUNICATIONS - BLOCK DIAGRAM

NOT TO SCALE

NOTES:

1. CABLES FROM EACH RACK TO BE

PHYSICALLY SEPARATED BY

DIFFERENT CABLE TRAYS

DESCRIBED IN E-121.

2. DOUBLE DATA OUTLETS

INDICATIVELY SHOWN SHARING /

SPLITTING TWO COMMUNICATION

SERVICES. EACH DOUBLE DATA

OUTLET SHOULD PROVIDE TWO

DESCRIBED SERVICES. USAF

SECURE AND UNSECURE WITHIN

THE SECURED AREA. AND USAF

UNSECURED AND AUS DPN WITHIN

THE UNSECURED AREA. OUTLETS

SHOULD APPROPRIATELY LABEL

SERVICES.

1x48 STRAND SOF FOR

DESN/BMS CONNECTION

TO BASE NETWORK

(NOTE 3)SPARE

RACK

DESN

E-603

E16929No.

NOTES

1. CONTRACTOR TO PROVIDE AND INSTALL 42 RU COMMUNICATIONS RACK.

CLIENT SHALL PROVIDE RACK EQUIPMENT. CONTRACTOR SHALL CONNECT

SPECIFIED OUTLETS TO RACK UPS SUPPLIED BY CLIENT.

2. FIBRE TO TERMINATE AT BUILDING 390. REFER TO DRAWING E-101 FOR CABLE

ROUTE.

3. COORDINATE DESN/BMS WITH BROAD SPECTRUM. FIBRE TO TERMINATE AT

SITE BMS CONTROLLER. REFER TO DRAWING E-101 FOR CABLE ROUTE.

4. ALL DESN/BMS SERVICES CONNECTING IN INTO BASE NETWORK MUST DO SO

VIA BLACK FIBRE TIE AT BUILDING COMMUNICATIONS RACK.

5. OUTLETS SHALL BE APPROPRIATELY LABELLED TO DENOTE WHICH RACK

THEY ARE SUPPLIED BY.

6. COORDINATE POWER SUPPLY TO VAV BOXES AND HVAC EQUIPMENT WITH

MECHANICAL EQUIPMENT CONTRACTOR.

RESERVED SPACE FOR

OWNER EQUIPMENT

(TYPICAL)

EQUIPMENT SUPPORT RAILS

(TYPICAL)

VENTED SHELF

(TYPICAL)

TYPICAL DATA RACK

FINISHED FLOOR

US

AF

S

AT

CO

M

AU

S

DP

N

P-700 P-400

US

AF

S

AT

CO

M

AU

S

DP

N

CONDUIT ROUTE

TO BLDG 390 BY

OTHERS

CONDUIT ROUTE

TO BLDG 452 BY

OTHERS

USAF

SATCOM

(BY

OTHERS)

(FUTURE) P-500

M13 x 74mm EMBEDMENT

EXPANSION…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .