APTIM-0013-4458-0513
Naval Facilities Engineering Command Southwest San Diego, CA
Final Limited Asbestos and Lead Assessment Report
Facility 43402 Marine Corps Base Camp Pendleton Camp Pendleton, California
December 2020
Prepared for:
Department of the Navy Naval Facilities Engineering Command Southwest 1220 Pacific Highway San Diego, CA 92132
Prepared by:
APTIM Federal Services, LLC 420 Exchange, Suite 150 Irvine, California 92602
MCBCP_43402_Report_Asbestos_Lead_0513_TO20F4458.docx APTIM-0013-4458-0513 N62473-17-D-0013 December 2020 1
LIMITED ASBESTOS AND LEAD ASSESSMENT REPORT
Facility 43402 Marine Corps Base Camp Pendleton Camp Pendleton, California
Contract Number: N62473-17-D-0013 Task Order: 20F4458 Document Control Number: APTIM-0013-4458-0513
December 2020
To: Mr. James Oliverez
Supervisory Engineering Technician Assistant Chief of Staff, GF (FAC)
FEAD/FSC
Planning/Technical MCB Camp Pendleton CA, 92055
From: 12/14/2020
Seyed Miri, Project Manager Date CAC (No. 92-0381)
APTIM Federal Services, LLC
Overview
Facility 43402 (Mess Hall) – Limited Asbestos and Lead Assessment Report Material Sampled: Sampling was limited to the thermal system insulation and walls of the mechanical room.
Asbestos Results: The analytical results and the site investigation indicated no presence of asbestos fibers in the sampled materials.
Lead-Based Paint (LBP) Results: The analytical result indicated no presence of lead referred to as LBP in the sampled paint.
Lead-Containing Paint (LCP) Results: The analytical result indicated no presence of lead referred to as LCP in the sampled paint.
Lead-Containing Material (LCM) Results: A visual inspection indicated no presence of potential lead containing materials within the designated area at the time of inspection.
N62473-17-D-0013 December 2020 2
Limited Asbestos and Lead Assessment Report
1. Subject: Facility 43402 (Mess Hall)
2. Inspections: Mr. Seyed Miri, a State of California Certified Asbestos Consultant and Lead Paint Inspector, performed a limited inspection for asbestos and lead paint on 12/01/2020.
3. Facility Description: Facility 43402 is a single-story structure and the date of construction is unknown. The facility may have undergone improvements over the course of time and is currently occupied.
4. Samples: A total of six (6) bulk samples were collected from six (6) homogeneous areas (HA) for asbestos content and one (1) sample was collected for lead content. Samples for asbestos content were submitted to AmeriSci Los Angeles in Carson, California and the sample for lead content was submitted to SGS Forensic Laboratories in Hayward, California.
5. Quality Control: To evaluate the precision and accuracy of the analytical data, six (6) split bulk samples were collected for asbestos content and submitted to SGS Forensic Laboratories in Hayward, California (see laboratory reports).
6. Previous Reports: No previous asbestos or lead assessment reports were available for the mechanical room at the time of inspection.
7. Materials Sampled: Sampling was non-destructive and only limited to accessible areas.
Lead assessment was limited to the painted surfaces and samples were not collected from industrial paint coating, spray painting, lead alloy, lead sheeting, lead-based alloy, pipes, solders, lead foils, anodes, etc. In addition, no samples were collected for asbestos content from concealed spaces and inaccessible materials (e.g., boilers, storage tanks, fire doors, trenches, pipe chases, wall cavities, buried pipes, equipment, electrical wiring, etc.).
8. Asbestos Hazard Ranking: An explicit hazard ranking is calculated for each homogeneous area based on its friability, condition, accessibility, quantity, exposure potential and percent asbestos present in the material (ranging from 0 to 87). The result is then combined by a letter or a series of letters indicating its condition (i.e., PD = Potential Damage, D = Damage, and SD = Significant Damage) to form the hazard ranking (ranging from PD0 to SD87, with PD0 being the lowest hazard ranking).
9. Asbestos Results: The analytical results and the site investigation indicated no presence of asbestos fibers in the sampled materials (see Table 1).
10. Lead-Based Paint (LBP) Results: The analytical result indicated no presence of lead referred to as LBP in the sampled paint (see Table 2).
Department of Housing and Urban Development (HUD) and United States Environment Protection Agency (EPA) define lead-based paint as paint or other surface coatings containing equal or more than 0.5 percent (5,000 mg/kg) lead.
https://www.amerisci.com/wp-content/uploads/2020/02/CA-NVLAP-Certs-2020.pdf http://www.falaboratories.com/documents/acc/aihahay.pdf http://www.falaboratories.com/documents/acc/nvlapairbulkhay.pdf http://www.falaboratories.com/documents/acc/nvlapairbulkhay.pdf
N62473-17-D-0013 December 2020 3
11. Lead-Containing Paint (LCP) Results: The analytical result indicated no presence of lead referred to as LCP in the sampled paint (see Table 2).
Consumer Product Safety Commission (CPSC) defines lead-containing paint as paint or other similar surface coating materials containing more than 0.009 percent (90 mg/kg) lead.
12. Lead-Containing Material (LCM) Results: A visual inspection indicated no presence of potential lead containing materials (e.g., ceramic tiles, sinks, etc.) at the time of inspection.
CPSC also defines materials such as ceramic glaze, which is bonded to the surface of a product as neither paints nor similar surface coating materials. For purposes of this inspection, any material containing any detectable level of lead is subject to OSHA’s Lead Exposure in Construction Rule (29 CFR Part 1926).
13. Quantities: The quantities in this report are estimates and limited to the inspected areas.
Materials may be hidden or mixed with other materials and may not be limited to the listed areas. The quantities and/or homogenous area locations as listed in this report should not be used as a basis for contractor bids or a request for a change order. A unit may be comprised of several components.
Note: Cross contamination to the surrounding areas or materials due to damaged and/or deteriorated asbestos containing materials and/or lead paint are not included in this report.
The following are included in this report:
• Figures
– Figure 1 – “Mechanical Room – Sample Locations of Suspect Asbestos-Containing Materials”
– Figure 2 – “Mechanical Room – Sample Locations of Suspect Lead”
• Tables
– Table 1 – “Summary of Asbestos Assessment”
– Table 2 – “Summary of Lead Assessment”
• Photo Logs
– Photo Log – “Suspect Asbestos-Containing Materials”
– Photo Log – “Suspect Lead” https://www.cpsc.gov/PageFiles/111614/regsumleadpaint.pdf https://www.ecfr.gov/cgi-bin/text-idx?SID=8cf6afe137f11e12278becc9635b84b6&mc=true&node=se16.2.1303_12&rgn=div8 https://www.cpsc.gov/PageFiles/111614/regsumleadpaint.pdf https://www.osha.gov/laws-regs/standardinterpretations/2003-07-18 https://www.osha.gov/pls/oshaweb/owadisp.show_document?p_id=10643&p_table=STANDARDS
N62473-17-D-0013 December 2020 4
• Field Notes
– Field Log – “Asbestos Bulk Sampling”
– Field Log – “Lead Bulk Sampling”
• Inspector’s Certifications
• Laboratory Reports – Results and Chain of Custody Forms
All disturbance and/or removal operations of materials containing greater than 0.1% asbestos (>0.1%) refers to as asbestos-containing construction material (ACCM) and materials containing greater than 1% asbestos (>1%) refers to as asbestos-containing material (ACM) must be performed by a Cal/OSHA registered and State licensed asbestos removal contractor in accordance with Title 8 of the California Code of Regulations, Section 1529 (8 CCR 1529).
Notification must be provided to Cal/OSHA 24 hours prior to commencing such activities of at least 100 square feet of materials in accordance with 8 CCR 1529 and 8 CCR 5203.
Any new suspect material or paint discovered during the renovation activities should be sampled by a State of California approved inspector and analyzed by an accredited laboratory to determine its composition.
An asbestos Operations and Maintenance (O&M) Program should be prepared and available to personnel, where asbestos is present. The O&M should include procedures to properly manage asbestos in place. Alternative methods such as repair, encapsulation, enclosure or removal may be utilized to minimize exposure to asbestos fibers.
Interim controls or abatement are part of the guidelines established by the Housing and Urban Development (HUD) to temporarily or permanently control exposure to lead particles.
Should the removal of friable or regulated ACMs involve at least 100 square feet, a ten working-day advance written notification to the San Diego Air Pollution Control District (SDAPCD) must be provided prior to any activity, including site preparation, that would break up, dislodge or similarly disturb the ACMs in accordance with Rule 1206.
A notice of intention is required for asbestos removal, renovation, and demolition operations in accordance with Rule 1206. The notification fees for demolitions and asbestos renovations are listed in District Rule 40.
San Diego Air Pollution Control District Compliance Division, Asbestos Section 10124 Old Grove Road San Diego, California 92131-1649 Phone: 858.586.266034 or email
Assembly Bill 3713, the Connelly Bill, (Health and Safety Code, Section 25915 et. seq.), requires building owners to disclose to employees the presence of any known ACM in the buildings constructed prior to 1979 within 15 days of knowledge.
https://www.dir.ca.gov/dosh/ACRU/ACRUhome.htm https://www.dir.ca.gov/Title8/1529.html https://www.dir.ca.gov/dosh/acru/acruinfo.htm https://www.dir.ca.gov/Title8/1529.html https://www.dir.ca.gov/title8/5203.html https://www.epa.gov/asbestos/how-develop-and-maintain-building-asbestos-operations-and-maintenance-om-program https://www.hud.gov/sites/documents/lbph-13.pdf https://www.hud.gov/sites/documents/CH12_ABATEMENT_121212.PDF https://www.sandiegocounty.gov/content/dam/sdc/apcd/PDF/Rules_and_Regulations/Workshops/R1206/R1206-WS_Draft.pdf http://www.sandiegocounty.gov/content/dam/sdc/apcd/PDF/Rules_and_Regulations/Workshops/R1206/R1206-WS_Draft.pdf http://www.sandiegocounty.gov/content/dam/sdc/apcd/PDF/Rules_and_Regulations/Fees/APCD_R40-2017.pdf mailto:apcdcomp@sdcounty.ca.gov https://leginfo.legislature.ca.gov/faces/codes_displayText.xhtml?lawCode=HSC&division=20.&title=&part=&chapter=10.4.&article=
N62473-17-D-0013 December 2020 5
All employers who use a regulated carcinogen (e.g., asbestos, cadmium, hexavalent chromium) that could potentially result in employee exposure, shall send a “report of use” to Cal/OSHA per
8 CCR 5203.
All planned renovations and demolition activities, involving the possible disturbance of LBP/LCP/LCM should be performed by a certified lead professional and waste should be characterized using the Toxicity Characteristic Leaching Procedure (TCLP) prior to disposal (40 CFR 261, Subpart C).
https://www.dir.ca.gov/title8/5203.html https://www.gpo.gov/fdsys/pkg/CFR-2012-title40-vol27/xml/CFR-2012-title40-vol27-part261-subpartC.xml https://www.gpo.gov/fdsys/pkg/CFR-2012-title40-vol27/xml/CFR-2012-title40-vol27-part261-subpartC.xml
N62473-17-D-0013 December 2020
Figures
U.S. DEPARTMENT OF THE NAVY
NAVAL FACILITIES ENGINEERING COMMAND SOUTHWEST
FIGURE 1 – MECHANICAL ROOM
FACILITY 43402
SAMPLE LOCATIONS OF SUSPECT ASBESTOS-CONTAINING
MATERIALS
MARINE CORPS BASE CAMP PENDLETON
CAMP PENDLETON, CALIFORNIA
DATE OF SURVEY: DECEMBER 1, 2020
Not to Scale
LEGEND
SAMPLE NUMBER
SAMPLE LOCATION, ASBESTOS FIBERS DETECTED
SAMPLE LOCATION, NO ASBESTOS FIBERS DETECTED
x
ASBESTOS FIBERS ARE DETECTED IN AT LEAST ONE SAMPLE IN THE HOMOGENEOUS AREA*
X
X
INACCESSIBLE
seyed.miri Callout 43402-1 seyed.miri Callout 43402-2 seyed.miri Callout 43402-3 seyed.miri Callout 43402-4 seyed.miri Callout 43402-5 seyed.miri Callout 43402-6
U.S. DEPARTMENT OF THE NAVY
NAVAL FACILITIES ENGINEERING COMMAND SOUTHWEST
FIGURE 2 – MECHANICAL ROOM
FACILITY 43402
SAMPLE LOCATIONS OF SUSPECT LEAD
MARINE CORPS BASE CAMP PENDLETON
CAMP PENDLETON, CALIFORNIA
DATE OF SURVEY: DECEMBER 1, 2020
Not to Scale x x SAMPLE NUMBER
LEGEND
X
X
SAMPLE LOCATION, LEAD EQUAL OR GREATER THAN 5,000 MG/KG (LBP) OR (LCM)
SAMPLE LOCATION, LEAD EQUAL OR GREATER THAN 90 MG/KG AND LESS THAN
5,000 MG/KG (LCP) OR (LCM)
SAMPLE LOCATION, LEAD LESS THAN 90 MG/KG
INACCESSIBLE
seyed.miri Highlight seyed.miri Callout 43402-1L
Tables
Table 1 - Summary of Asbestos Assessment Facility No: 43402 Marine Corps Base Camp Pendleton, Camp Pendleton, California Date of Survey: 12/01/2020
Facility Number Facility Description Year Built
No. of Stories
Information Source
Year of Sample Sample ID HA No. HA Description HA Categories HA Location (map)1 Quantity Friability Condition
Accessibility / No. of persons exposed % Asbestos in
Layer(s)
Total % Asbestos
(PLM)^
% Asbestos (Point count)
Asbestos Type Score Recommended Action
43402 Mess Hall Not Available 1 APTIM 2020 43402-1 1 White/yellow thermal system insulation, pipe end cap TSI Mechanical room 300 LF F D ANO/0 NAD NAD NA N/A D0 None
43402 Mess Hall Not Available 1 APTIM 2020 43402-1^^ 1 White/silver/yellow thermal system insulation, pipe end cap TSI Mechanical room I.A. F D ANO/0 NAD NAD NA N/A D0 None
43402 Mess Hall Not Available 1 APTIM 2020 43402-2 2 White thermal system insulation & white vinyl cover, elbow TSI Mechanical room 50 Units F PD ANO/0 NAD NAD NA N/A PD0 None
43402 Mess Hall Not Available 1 APTIM 2020 43402-2^^ 2 White thermal system insulation & white vinyl cover, elbow TSI Mechanical room I.A. F PD ANO/0 NAD NAD NA N/A PD0 None
43402 Mess Hall Not Available 1 APTIM 2020 43402-3 3 White/yellow thermal system insulation, tank TSI Mechanical room 1 Unit F PD ANO/0 NAD NAD NA N/A PD0 None
43402 Mess Hall Not Available 1 APTIM 2020 43402-3^^ 3 White/yellow thermal system insulation, tank TSI Mechanical room I.A. F PD ANO/0 NAD NAD NA N/A PD0 None
43402 Mess Hall Not Available 1 APTIM 2020 43402-4 4 White gasket, boiler Miscellaneous Mechanical room 2 Units F PD ANO/0 NAD NAD NA N/A PD0 None
43402 Mess Hall Not Available 1 APTIM 2020 43402-4^^ 4 White gasket, boiler Miscellaneous Mechanical room I.A. F PD ANO/0 NAD NAD NA N/A PD0 None
43402 Mess Hall Not Available 1 APTIM 2020 43402-5 5 Grey cementitious wall Miscellaneous Mechanical room 2,000 SF NF PD ANO/0 NAD NAD NA N/A PD0 None
43402 Mess Hall Not Available 1 APTIM 2020 43402-5^^ 5 Grey cementitious wall Miscellaneous Mechanical room I.A. NF PD ANO/0 NAD NAD NA N/A PD0 None
43402 Mess Hall Not Available 1 APTIM 2020 43402-6 6 Tan textured concrete coating, wall Miscellaneous Exterior, southwest 1,400 SF NF PD ANO/0 NAD NAD NA N/A PD0 None
43402 Mess Hall Not Available 1 APTIM 2020 43402-6^^ 6 Tan textured concrete coating, wall Miscellaneous Exterior, southwest I.A. NF PD ANO/0 NAD NAD NA N/A PD0 None
Notes:
& ILE
' INE
" JC
< LF
- - LC
% MA mastic
ACM N/A
ANO NA
AO NAD
BB NF
CM cementitious material No.
D O&M
F PC
FT PD
GB SD
HA SF
I.A. TSI
split bulk sample asbestos fibers are detected at least in one sample in the homogeneous area quantities are reported per layers gypsum board sample location homogenous area significant damage (>10% evenly or >25% localized) square feet included above thermal system insulation total % asbestos is sum of % asbestos in layers and not reflective of the composite value of the sample number damaged (<10% evenly or <25% localized) friable floor tile operation and maintenance epa 400 or 1,000 point count potential damage not analyzed accessible and occupied baseboard no asbestos detected non-friable and feet inaccessible and likely to expose inaccessible and not likely to expose inch less than none or not applicable joint compound linear feet leveling compound percent asbestos-containing material accessible and not occupied not applicable
Table 2 - Summary of Lead Assessment
Marine Corps Base Camp Pendleton, Camp Pendleton, California Date of Survey: 12/01/2020
Facility Number Facility Description Year Built
Number of Stories Sample ID Interior / Exterior Sample Location Facility Component Substrate (Material Type) Material Color
Quantity (Square feet/ Linear feet) Condition
Lead Results (ppm=mg/kg)
Lead Results (POS/NEG) Comments Recommended Action
43402 Mess Hall Not Available 1 43402-1L Exterior Mechanical room Wall Concrete Tan 1,400 SF Intact <60 NEG ---- ----
Notes:
Abatement I.A.
Interim Controls
LBP
LCM
LCP
LF
mg/kg ppm
NA
NEG
NEG* containing detectable concentration of lead, less than or equal to 0.009 percent lead (w/w); 90 mg/kg
NQ
POS*
POS
SF
containing greater than or equal to 0.5 percent lead (w/w); 5,000 mg/kg square feet not applicable not analyzed due to low quantity of sample containing greater than 0.009 percent lead (w/w); 90 mg/kg and less than 0.5 percent lead (w/w); 5,000 mg/kg greater than less than designed to permanently eliminate (at least 20 years) existing lead hazard included above designed to minimize or eliminate (less than 20 years) existing lead hazard lead-based paint lead-containing material lead-containing paint linear feet milligram per kilogram part per million below detection limit not quantified
Photo Logs
HA-5 Grey cementitious wall sampled. No Asbestos Fibers Detected.
HA-6 Tan textured concrete coating, wall sampled.
No Asbestos Fibers Detected.
Marine Corps Base Camp Pendleton, Camp Pendleton, California
Photo Log - Suspect Asbestos-Containing Materials
Date of Survey: 12/01/2020
Facility 43402 HA-1 White/yellow thermal system insulation, pipe end cap sampled. No Asbestos Fibers Detected.
HA-2 White thermal system insulation & white vinyl cover, elbow sampled. No Asbestos Fibers
Detected.
HA-3 White/yellow thermal system insulation, tank sampled. No Asbestos Fibers Detected.
HA-4 White gasket, boiler sampled. No Asbestos Fibers Detected.
Photo Log - Suspect Lead
Marine Corps Base Camp Pendleton, Camp Pendleton, California Date of Survey: 12/01/2020
43402-1L - Exterior, Wall, Concrete, Tan (NEG)Facility 43402
Field Notes
Sample ID HA No. HA Description (Material Sampled / Color) HA Categories Sample Location
Quantity (square feet / linear feet / units)
Friability
(NF/F)
Condition
(PD/D/SD)
Accessibility/ No. of Persons
Exposed
43402-1^^ 1 White/yellow thermal system insulation, pipe end cap TSI Mechanical room 300 LF F D ANO/0
43402-2^^ 2 White thermal system insulation & white vinyl cover, elbow TSI Mechanical room 50 Units F PD ANO/0
43402-3^^ 3 White/yellow thermal system insulation, tank TSI Mechanical room 1 Unit F PD ANO/0
43402-4^^ 4 White gasket, boiler Miscellaneous Mechanical room 2 Units F PD ANO/0
43402-5^^ 5 Grey cementitious wall Miscellaneous Mechanical room 2,000 SF NF PD ANO/0
43402-6^^ 6 Tan textured concrete coating, wall Miscellaneous Exterior, southwest 1,400 SF NF PD ANO/0
Condition:
PD = Potential Damage Surfacing D = Damaged Thermal System Insulation SD = Significant Damage Miscellaneous
Friability:
Re-Inspection
Accessibility:
AO = Accessible and Occupied ANO = Accessible and Not Occupied ILE = Inaccessible and Likely to Expose
^^ Split Bulk Sample
F = Friable NF = Non-Friable
HA Categories:
INE = Inaccessible and Not Likely to Expose
Inspection Type:
Limited Baseline
ASBESTOS BULK SAMPLING - FIELD LOG
Date:
Facility Name:
Facility Number:
Seyed Miri
12/01/2020 Mess Hall 43402 20F4458 Limited () - Baseline ( ) - Reinspection ( )
Task Order:
Inspection Type:
Inspector(s):
Sample ID Interior / Exterior Sample Location Facility Component
Substrate (Material
Type) Material Color
Quantity (square feet / linear feet) Condition Comments
43402-1L Exterior Mechanical room Wall Concrete Tan 1,400 SF Intact
Date: 12/01/2020
Facility Name: Mess Hall
Facility Number: 43402
LEAD BULK SAMPLING - FIELD LOG
Task Order: 20F4458
Inspection Type: Limited () - Baseline ( ) - Reinspection ( )
Inspector(s): Seyed Miri
Inspector’s Certifications
ASBESTOS CERTIFICATION
LEAD CERTIFICATION
Laboratory Reports
Final Repor
(EPA Method 40CFR, Part 763, Appendix E to Subpart E and EPA 600/R-93-116, Visual Area Estimation) Bulk Asbestos Analysis
NVLAP Lab Code: 101459-0 L1852Client ID:APTIM B310973Report Number:Seyed Miri
Date Received:420 Exchange Road 12/07/20Date Analyzed:Suite 150 12/09/20Date Printed:Irvine, CA 92602
First Reported:
L1852500996; 20F4458, 20L120Z - Facility No.43402 SGSFL Job ID:Job ID/Site:
Date(s) Collected: 12/01/2020 6Total Samples Submitted:
Total Samples Analyzed: 6
12/02/20
12/09/20
Sample ID Lab Number Asbestos
Type Percent in
Layer Asbestos AsbestosPercent in Percent in
Type TypeLayer Layer
43402-1 12361249 Layer: Yellow Fibrous Material ND Layer: Off-White Non-Fibrous Material ND
Asbestos (ND)Total Composite Values of Fibrous Components:
Cellulose (Trace) Fibrous Glass (90 %)
43402-2 12361250 Layer: White Fibrous Material ND Layer: White Non-Fibrous Material ND Layer: Clear Mastic ND
Asbestos (ND)Total Composite Values of Fibrous Components:
Cellulose (Trace) Fibrous Glass (85 %)
43402-3 12361251 Layer: Yellow Fibrous Material ND Layer: White Woven Material ND
Asbestos (ND)Total Composite Values of Fibrous Components:
Cellulose (10 %) Fibrous Glass (85 %)
43402-4 12361252 Layer: White Fibrous Material ND
Asbestos (ND)Total Composite Values of Fibrous Components:
Cellulose (Trace) Fibrous Glass (54 %) Synthetic (45 %)
43402-5 12361253 Layer: Grey Cementitious Material ND
Asbestos (ND)Total Composite Values of Fibrous Components:
Cellulose (Trace)
43402-6 12361254 Layer: Off-White Non-Fibrous Material ND Layer: Paint ND
Asbestos (ND)Total Composite Values of Fibrous Components:
Cellulose (Trace) Fibrous Glass (2 %)
3777 Depot Road, Suite 409, Hayward, CA 94545 / Telephone: (510) 887-8828 (800) 827-FASI / Fax: (510) 887-4218
Report Number: B310973 Date Printed: 12/09/20Client Name: APTIM
Sample ID Lab Number Asbestos
Type Percent in
Layer Asbestos AsbestosPercent in Percent in
Type TypeLayer Layer
Analytical results and reports are generated by SGS Forensic Laboratories (SGSFL) at the request of and for the exclusive use of the person or entity (client) named on such report.
Results, reports or copies of same will not be released by SGSFL to any third party without prior written request from client. This report applies only to the sample(s) tested.
Supporting laboratory documentation is available upon request. This report must not be reproduced except in full, unless approved by SGSFL. The client is solely responsiblefor the use and interpretation of test results and reports requested from SGSFL. SGSFL is not able to assess the degree of hazard resulting from materials analyzed. SGS Forensic Laboratories reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. All samples were received in acceptable condition unless otherwise noted.
Note: Limit of Quantification ('LOQ') = 1%. 'Trace' denotes the presence of asbestos below the LOQ. 'ND' = 'None Detected'.
Tad Thrower, Laboratory Supervisor, Hayward Laboratory
3777 Depot Road, Suite 409, Hayward, CA 94545 / Telephone: (510) 887-8828 (800) 827-FASI / Fax: (510) 887-4218
Metals Analysis of Paints Client ID:
Report Number:
Date Received:
M230193
Job ID / Site: 500996; 20F4458, 20L120Z - Facility No.43402
APTIM
Suite 150
L1852
SGSFL Job ID:
Date Analyzed:
L1852
Seyed Miri
Irvine, CA 92602
420 Exchange Road
Date Printed: 12/04/20 12/04/20
First Reported: 12/04/20
12/02/20
Final Report
(AIHA-LAP, LLC Accreditation, Lab ID #101762)
Date(s) Collected: 12/01/20 Total Samples Submitted:
Total Samples Analyzed:
Sample Number Lab Number Result Result Reporting Method
Analyte Units Limit* Reference
EPA 3050B/7000B< 60Pb43402-1L 30879913 ppm 60
Analytical results and reports are generated by SGS Forensic Laboratories at the request of and for the exclusive use of the person or entity (client) named on such report. Results, reports or copies of same will not be released by SGS Forensic Laboratories to any third party without prior written request from client. This report applies only to the sample(s) tested. Supporting laboratory documentation is available upon request. This report must not be reproduced except in full, unless approved by SGS Forensic Laboratories. The client is solely responsible for the use and interpretation of test results and reports requested from SGS Forensic Laboratories. SGS Forensic Laboratories is not able to assess the degree of hazard resulting from materials analyzed. SGS Forensic Laboratories reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Any modifications that have been made to referenced test methods are documented in SGS Forensic Laboratories' Standard Operating Procedures Manual. Sample results have not been blank corrected. Quality control and sample receipt condition were acceptable unless otherwise noted.
Note* Sampling data used in this report was provided by the client as noted on the associated chain of custody form.
* The Reporting Limit represents the lowest amount of analyte that the laboratory can confidently detect in the sample, and is not a regulatory level. The Units for the Reporting Limit are the same as the Units for the Final Results.
Kevin Poon, Laboratory Analyst, Hayward Laboratory
3777 Depot Road, Suite 409, Hayward, CA 94545 / Telephone: (510) 887-8828 (800) 827-FASI / Fax: (510) 887-4218
| Cover Page |
| Overview |
| Limited Asbestos and Lead Assessment Report |
| Figures |
| FIGURE 1 – MECHANICAL ROOM - SAMPLE LOCATIONS OF SUSPECT ASBESTOS-CONTAINING MATERIALS |
| FIGURE 2 – MECHANICAL ROOM - SAMPLE LOCATIONS OF SUSPECT LEAD |
| Tables |
| Table 1 - Summary of Asbestos Assessment |
| Table 2 - Summary of Lead Assessment |
| Photo Logs |
| Photo Log - Suspect Asbestos-Containing Materials |
| Photo Log - Suspect Lead |
| Field Notes |
| ASBESTOS BULK SAMPLING - FIELD LOG |
| LEAD BULK SAMPLING - FIELD LOG |
| Inspector’s Certifications |
| Asbestos & Lead Certifications |
| Laboratory Reports |
| AmeriSci - Asbestos Report & Chain of Custody Form |
| SGSFL - Asbestos Report & Chain of Custody Form |
| SGSFL - Lead Report & Chain of Custody Form |
File details come from the government source that posted it. Updated .