Text version
AUTHORITY:
NAVSEA SYSTEM CERTIFICATION
AUTHORITY SYSTEM CERTIFICATION
SURVEY CARD NO. 13 OF 23 AUGUST
COGNIZANT CODE:
PREPARED
DATE
CHECKED
ENGINEER
APPROVED
PORTSMOUTH NAVAL
SHIPYARD
PORTSMOUTH, NH 03804
CAGE 81316
PREPARED
John Webber /S/
DATE
9/14/04
CHECKED
Dan Will /S/
9/21/04
ENGINEER
John Webber /S/
9/14/04
BR HD
Dan Will /S/
9/21/04
APPROVED
N. S. Grammenos /S/
9/23/04
ACCEPTED FOR NAVSEA
APPROVED BY NAVSEA
REVISION (B) OF THIS DRAWING APPROVED
BY NAVSEA LETTER SER 394C/0268 DATED 18
MAY 2005
COMPUTER MAINTAINED. CHANGES WILL BE
INCORPORATED BY THE DESIGN ACTIVITY. THIS
DRAWING WAS DEVELOPED USING MS WORD 2000
SCOPE
OF
CERTIFICATION
DEPARTMENT OF THE NAVY
NAVAL SEA SYSTEMS COMMAND
WASHINGTON DC 20362
Atmospheric Diving System (ADS)
Launch and Recovery System (LARS) Vessel of Opportunity (VOO)
Mounting Procedure
A D S L A R S M O U N T P R O C E D U R E
SIZE CAGE NO. WT GRP NAVSEA DRAWING NO REV
A 81316 594 6395636 D
SCALE: NONE SHEET 1 OF 28
DISTRIBUTION STATEMENT A: APPROVED FOR PUBLIC RELEASE;
DISTRIBUTION IS UNLIMITED
SIZE CAGE NO. REVNAVSEA DRAWING NO.WT GRP
A 53711
SCALE: NONE SHEET 2
845 6395635 D
Revisions
SHEET REV DESCRIPTION BY DATE APPROVED
- Release Not approved
7-14, 21-23 A Incorporated NAVSEA comments provided by NAVSEA ltr 4855 ser 395/1145 of 2 Dec 04 JJW 1/4/05
/S/ Dan Will 2/1/05
/S/ N. S. Grammenos 2/2/05
Not Approved by NAVSEA
1-30 B Incorporated NAVSEA comments, added non- LARS diving information
JJW 5/16/05
/S/ Dan Will 5/19/05
/S/ N. S. Grammenos 5/19/05
/S/ J. M. Higgins 5/19/05
NAVSEA LETTER
SER 394C/0268
DATED 18 MAY 2005
5,19-20 C Revised the non-LARS diving trolley welded attachment to use rectangular tubes instead of footer plates.
JJW 7/1/09 Not Approved
D
Sh 3. Replaced ref (10), added ref (12) Sh 4. Deleted Appendices E, F.
Sh 5 1.0 Added OP citation to scope, added allowance to reuse installations to sac. tabs and rect. tubes Sh 6. Added ref (12) citation, optional hose length (sch. 205.2-196-10) 5.0, 6.0, 7.0 Rm specific torque wrench, made laser leveling optional, update bolt spec (sch 205.2-216-09), added square washers ( sch.
205.2-260-11), corr. fastener qty’s, added reuse of installations Sh 11. Corrected Fig 2 weld symbol (sch 205.2- 42-11) Sh 12. Added trimming of tabs, shimming LARS (sch. 205.2-460-10)
9.0 Rm specific torque wrenches, update bolt
spec (sch 205.2-216-09)
9.2.8 Changed torque to 36 ft-lbs.
10.0 Updated procedure to ref (11) Rev A cfg., rm specific torque wrench, added use of ref (10), added reuse of installations App. H. Added trolley welded installation record
JJW 12 Sep 11
/S/ N.S. Grammenos 9/27/11
NAVSEA LETTER
SER 394R/0870
DATED 21 Dec 11
Applicability:
This drawing is applicable to:
ADS 2000 Launch and Recovery Systems Units 001, 002, 003
Applicability of this drawing to other assets must be determined by PNS (Code 205) & NAVSEA PMS394R.
A 81316
SCALE: NONE SHEET 3
D 594 6395636
SHEET LAST DIGIT NUMBER
0 1 2 3 4 5 6 7 8 9
0 D D D D D D D D D 1 D D D D D D D D D D 2 D D D D D D D D D
REVISION STATUS
OF SHEETS
NAVSEA 395A3 1
NAVSEA 394C 1
NAVSEA 394R 1 1
CSDS-5
DSU - QA DEPT 1
DSU 1
205 (ADS Project) 1 1 1 1
ISSUE
DATE
REVISION - A B C D
PRINTS ISSUED
12 AUWS and Submarine Rescue Chamber VOO Deck Layout 594-7329708
11 Trolley Welded Tube Mounts 594-7329713
10 Remove/Install Procedure 16 – Remove/Install LARS Trolley Assembly SS520-AU-SCB-010/ADS, APPENDIX D, RIP16
9 ADS LARS Trolley Footer Plates 594-7329590
8 System Certification Procedures and Criteria Manual for Deep Submergence Systems SS800-AG-MAN-010/P-9290
7 NAVSEA ltr 4855 ser 395/1037 of 1 Nov 04 N/A
6 Sacrificial Weld Down Plates, Dynacon Inc. 468-1005-20 Rev. -
5 Nondestructive Testing Acceptance Criteria MIL-STD-2035A
4 Structural Welding Code – Steel, American Welding Society (AWS) D1.1
3 LARS Skid Erection Set Up Pre-Mission SS520-AU-SCB-010/ADS, APPENDIX H, OP2
2 LARS Hydraulic / Electric Interface Set Up Pre-Mission SS520-AU-SCB-010/ADS, APPENDIX H, OP1
1 ISKID General Assembly, Dynacon, Inc. 5006-6101-01
NO. TITLE IDENT
REFERENCES
SCALE: NONE SHEET 4
TABLE OF CONTENTS
1. Purpose and Scope
2. Attachment Methods
3. Constraints
3.1 VOO Qualification
3.2 Detailed Constraints
4. LARS Mounting Method Selection
5. Intermediate Skid Baxter Bolt Installation
6. Intermediate Skid Welded Installation
7. Sacrificial Tab Installation
8. Post-Installation Load Test
9. Non-LARS Diving, Trolley Bolted Attachment
10. Non-LARS Diving, Trolley Welded Attachment
Appendices:
A. VOO Baxter bolt strength and position requirements
B. Intermediate skid general arrangement
C. Intermediate skid allowable obstructions
D. Sacrificial tab
E. Deleted
F. Deleted
G. Trolley footer plate positioning
H. LARS installation record
SCALE: NONE SHEET 21
APPENDICES
SCALE: NONE SHEET 22
Appendix A. VOO Baxter bolt strength and position requirements