This is an Asbestos Inspection Report for Building FC571, a Bachelor Enlisted Quarters (BEQ) facility located at MCB Camp Lejeune, dated March 19, 2026. The building was constructed in 1986 and currently holds a Hazard Rank 3/Green classification as of March 2023. The report documents the identification and tracking of asbestos-containing materials (ACM) through multiple inspection cycles dating back to 2002, with the most recent survey completed in March 2023.

The building contains only non-friable ACM, with no friable materials identified. Current ACM in the structure includes: residual mastic remnants of HM01 mastic located at doorways and potential areas under new flooring throughout (1 SF, identified 12/9/2013), and roofing sealant in gray color located in the attic at the old roof perimeter and parapet flashings (2,700 SF, identified 5/18/2010 and reconfirmed 9/18/2019). Extensive historical sampling data is provided documenting materials tested as non-ACM or removed since 2002, including various floor tiles, ceiling materials, duct sealants, exterior caulking, and roofing components. The report emphasizes that intact and undisturbed ACM does not pose a significant health hazard to occupants. Building occupants are instructed to avoid disturbing ACM materials and to report any damage or debris to the Asbestos Program Manager at (910) 451-5837. Periodic inspections will continue to monitor any changes in material condition, with the Camp Lejeune Asbestos Program Manager maintaining records of the survey.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ASBESTOS INSPECTION REPORT of:

Building # FC571

MCB CAMP LEJEUNE

Thursday, March 19, 2026

Print Date

Thursday, March 19, 2026 Page 1 of 8Print Date:

INSPECTION SUMMARY

BLDG #:

OCCUPANT:

YEAR BUILT:

BUILDING COMMENTS:

FC571

BEQ

HAZ RANK 3/GREEN [MAR2023]

ROOFING SEALANT

MAR2023

ACM REMAINS

SEPT2019

NO CHANGES, ADDL SAMPLING

JUN2016

ACM REMAINS

DEC2013

ACM ROOFING REMAINS, ADDL SAMPLING, ACM INCLUDES:

RESIDUAL MASTIC

MAY2010

PVS. TILE AND MASTIC REPLACED, CONFIRMATIONS TEM/ PLM. ADDL FULL SAMPLING, ACM IDENTIFIED INCLUDES:

ROOFING SEALANT, GRAY

SEPT05

PVS. ACM TILE AND MASTIC REMAINS.

INSPECT JUL02- AES

HOMO GROUPING, FC525, FC555 PRIMARY FOR AREA BEQS. ACM INCLUDES:

12" BEIGE TILE AND MASTIC

ASBESTOS MANAGER: 910-451-5837

Friable ACM(s) identified

Non-friable ACM(s) identified

NOTICE: The following asbestos-containing materials have been identified in this structure. Refer to survey findings for additional information or contact the Asbestos Program Manager. Please note ACM that is intact and undisturbed is not considered a significant health hazard to building occupants.

DESCRIPTION LOCATION Date Quantity

DESCRIPTION LOCATION Date Quantity

No friable ACM records found in database

NOTIFICATION OF ACM IN BUILDING

RESIDUAL MASTIC 1 SFREMNANTS OF HM01 MASTIC AT "NEW"

DOORWAYS TO ROOMS; POTENTIAL

UNDER NEW FLOORING THROUGHOUT

12/9/2013

ROOFING SEALANT, GRAY 2,700 SFATTIC [OLD ROOF] PERIMETER

PARAPET FLASHINGS

5/18/2010

ROOFING SEALANT, GRAY 2,700 SFATTIC [OLD ROOF] PERIMETER

PARAPET FLASHINGS

9/18/2019

Thursday, March 19, 2026 Page 2 of 8Print Date:

Tested Non ACM or REMOVED Materials

DESCRIPTION LOCATION Date

RESIDUAL MASTIC 1 SFREMNANTS OF HM01 MASTIC AT "NEW"

DOORWAYS TO ROOMS; POTENTIAL

UNDER NEW FLOORING THROUGHOUT

9/18/2019

ROOFING SEALANT, GRAY 2,700 SFATTIC [OLD ROOF] PERIMETER

PARAPET FLASHINGS

12/9/2013

ROOFING SEALANT, GRAY 2,700 SFATTIC [OLD ROOF] PERIMETER

PARAPET FLASHINGS

6/9/2016

RESIDUAL MASTIC 3 SFREMNANTS OF HM01 MASTIC AT "NEW"

DOORWAYS TO ROOMS; POTENTIAL

UNDER NEW FLOORING THROUGHOUT

6/9/2016

ROOFING SEALANT, GRAY 2,700 SFATTIC [OLD ROOF] PERIMETER

PARAPET FLASHINGS

3/28/2023

RESIDUAL MASTIC 1 SFREMNANTS OF HM01 MASTIC AT "NEW"

DOORWAYS TO ROOMS; POTENTIAL

UNDER NEW FLOORING THROUGHOUT

3/28/2023

TAR PAPER, BLACK ATTIC [OLD ROOF] PERIMETER

FLASHINGS AND MEMBRANE

5/18/2010

12" BEIGE FLOOR TILE AND ADHESIVE SECOND FLOOR LOUNGE (UNDER

CARPET)

7/18/2002

TEXTURED CEILING MATERIAL OFFICES AND LIVING QUARTERS

THROUGHOUT

7/18/2002

MUDDED FITTING(S) MECHANCIAL ROOMS AND CENTER

PIPE CHASES

7/18/2002

12" BEIGE FLOOR TILE AND ADHESIVE THIRD FLOOR LOUNGE 7/18/2002

DUCT SEALANT, RED MECHANICAL ROOMS AND CENTER

PIPE CHASES

7/18/2002

12" CREAM FLOOR TILE AND ADHESIVE CENTRAL HALLWAYS 9/20/2005

EXTERIOR CAULKING, DOORS AND BRICK JOINTS 9/20/2005

DUCT SEALANT, GRAY CHASES AND ATTIC/ OLD ROOF DUCTS

THROUGHOUT

9/20/2005

BUILT-UP ROOFING ATTIC [OLD ROOF] MAIN MEMBRANE 5/18/2010

DUCT SEALANT, TAN NORTH AND SOUTH WING

MECHANICAL ROOMS HVAC DUCTS

5/18/2010

DUCT SEALANT, WHITE NORTH AND SOUTH WING

MECHANICAL ROOMS HVAC DUCTS

5/18/2010

CLOTH EXPANSION JOINT MATERIAL, THIN NORTH AND SOUTH WING

MECHANICAL ROOMS AHU UNITS

5/18/2010

DRYWALL AND JOINT MATERIAL DORM ROOM CEILINGS AT HEADS

THROUGHOUT

5/18/2010

LAGGING PAPER ON FIBERGLASS FIRST FLOOR NORTH MECHANICAL

ROOM TANK

5/18/2010

Thursday, March 19, 2026 Page 3 of 8Print Date:

ACM only presents a health hazard when asbestos fibers are airborne and inhaled.

Avoid disturbance which will release fibers. The presence of asbestos does not constitute a health hazard.

HEALTH ASPECTS:

Do not disturb or cause damage to ACM. Do not sand, grind or abrade materials or cause damage with any type of equipment.

CONDITIONS TO AVOID:

Report any damage, dust or debris that may come from ACM or suspect ACM, or any change in the condition of materials, or accidental disturbance to the Asbestos

Program Manager.

REPORTS OF DAMAGE:

Corrective action initiated to minimize fiber release and protect personnel. RESPONSE ACTION:

ACM will be inspected periodically to evaluate any changes in condition.INSPECTION:

The Camp Lejeune Asbestos Program Manager maintains a copy of the survey for the building.

RECORDKEEPING:

CAMP LEJEUNE Asbestos Program Manager: Phone: (910) 451-5837

ROOFING SEALANT, BLACK ATTIC [OLD ROOF] PERIMETER

FLASHINGS

5/18/2010

12" BEIGE FLOOR TILE AND ADHESIVE THROUGHOUT OFFICES, LIVING

QUARTERS, AND LOUNGES (HM01, 02

TILES)

7/18/2002

12" BLACK FLOOR TILE AND ADHESIVE CENTRAL LOUNGES 7/18/2002

12" WHITE FLOOR TILE AND ADHESIVE CENTRAL LOUNGES 7/18/2002

2'x2' CEILING TILE, OFFICES AND CENTRAL LOUNGES 7/18/2002

TAR PAPER, BLACK ATTIC [OLD ROOF] PERIMETER

FLASHINGS AND MEMBRANE

9/18/2019

TEXTURED CEILING MATERIAL OFFICES AND LIVING QUARTERS

THROUGHOUT

9/20/2005

TEXTURED CEILING MATERIAL OFFICES AND LIVING QUARTERS

THROUGHOUT

5/18/2010

EXTERIOR CAULKING, DOORS AND BRICK JOINTS 5/18/2010

DUCT SEALANT, GRAY CHASES AND ATTIC/ OLD ROOF DUCTS

THROUGHOUT

5/18/2010

12" BEIGE FLOOR TILE AND ADHESIVE REPLACED HM03 PRIMARY TILE

THROUGHOUT OFFICES, LIVING

QUARTERS, AND LOUNGES (HM01. 02

TILES)

5/18/2010

Thursday, March 19, 2026 Page 4 of 8Print Date:

SAMPLES COLLECTED

Sample Sample

Date

HA Sample Location Chr

Amo

Oth

Description

FC525-01-01 7/18/200201 1ST FL LOUNGE FC525 0 0 012" BLACK FLOOR TILE

AND ADHESIVE

FC525-01-02 7/18/200201 1ST FL LOUNGE FC525 0 0 012" BLACK FLOOR TILE

AND ADHESIVE

FC525-02-03 7/18/200202 1ST FL LOUNGE FC525 0 0 012" WHITE FLOOR TILE

AND ADHESIVE

FC525-02-04 7/18/200202 1ST FL LOUNGE FC525 0 0 012" WHITE FLOOR TILE

AND ADHESIVE

FC525-03-05 7/18/200203 1ST FL LOUNGE FC525 8 0 012" BEIGE FLOOR TILE

AND ADHESIVE

TYPE I

FC525-03-06 7/18/200203 1ST FL LOUNGE FC525 8 0 012" BEIGE FLOOR TILE

AND ADHESIVE

TYPE I

FC571-03-00RI05 9/20/200503 N/A 9 9 912" BEIGE FLOOR TILE

AND ADHESIVE

TYPE I

FC525-04-07 7/18/200204 1ST FL LOUNGE FC525 0 0 02'x2' CEILING TILE, FC525-04-08 7/18/200204 1ST FL LOUNGE FC525 0 0 02'x2' CEILING TILE, FC525-05-09 7/18/200205 2ND FL LOUNGE FC525 10 0 012" BEIGE FLOOR TILE

AND ADHESIVE

TYPE II

FC571-05-00RI05 9/20/200505 N/A 9 9 912" BEIGE FLOOR TILE

AND ADHESIVE

TYPE II

FC525-06-10 7/18/200206 3RD FL LOUNGE FC525 10 0 012" BEIGE FLOOR TILE

AND ADHESIVE

TYPE III

FC571-06-00RI05 9/20/200506 N/A 9 9 912" BEIGE FLOOR TILE

AND ADHESIVE

TYPE III

FC571-06-20 5/18/201006 1ST FL SOUTH, SE ROOM 0 0 012" BEIGE FLOOR TILE

AND ADHESIVE

TYPE III

FC571-06-20tem 5/18/201006 1ST FL SOUTH, SE ROOM 0 0 012" BEIGE FLOOR TILE

AND ADHESIVE

TYPE III

FC571-06-21 5/18/201006 1ST FL NORTH, NW ROOM 0 0 012" BEIGE FLOOR TILE

AND ADHESIVE

TYPE III

FC571-06-22 5/18/201006 2ND FL NORTH, NE ROOM 0 0 012" BEIGE FLOOR TILE

AND ADHESIVE

TYPE III

FC571-06-22tem 5/18/201006 2ND FL NORTH, NE ROOM 0 0 012" BEIGE FLOOR TILE

AND ADHESIVE

TYPE III

FC571-06-23 5/18/201006 2ND FL SOUTH, SW ROOM 0 0 012" BEIGE FLOOR TILE

AND ADHESIVE

TYPE III

Thursday, March 19, 2026 Page 5 of 8Print Date:

HA Sample Location Chr

Amo

Oth

Description

FC571-06-24 5/18/201006 3RD FL SOUTH, SE ROOM 0 0 012" BEIGE FLOOR TILE

AND ADHESIVE

TYPE III

FC571-06-24tem 5/18/201006 3RD FL SOUTH, SE ROOM 0 0 012" BEIGE FLOOR TILE

AND ADHESIVE

TYPE III

FC571-06-25 5/18/201006 3RD FL NORTH, NW ROOM 0 0 012" BEIGE FLOOR TILE

AND ADHESIVE

TYPE III

FC525-07-11 7/18/200207 1ST FL MECH ROOM FC525 0 0 0DUCT SEALANT, RED

FC525-08-12 7/18/200208 1ST FL MECH ROOM FC525 0 0 0MUDDED FITTING(S)

FC525-08-13 7/18/200208 3RD FL MECH ROOM FC525 0 0 0MUDDED FITTING(S)

FC525-09-14 7/18/200209 1ST FL OFFICE 0 0 0TEXTURED CEILING

MATERIAL

FC525-09-15 7/18/200209 1ST FL OFFICE 0 0 0TEXTURED CEILING

MATERIAL

FC571-09-1110 9/20/200509 1ST FL LAUNDRY 0 0 0TEXTURED CEILING

MATERIAL

FC571-09-1310 9/20/200509 2ND FL WEST CNTR RM 0 0 0TEXTURED CEILING

MATERIAL

FC571-09-20 5/18/201009 1ST FL SOUTH, SE ROOM 0 0 0TEXTURED CEILING

MATERIAL

FC571-09-21 5/18/201009 1ST FL NORTH, NW ROOM 0 0 0TEXTURED CEILING

MATERIAL

FC571-09-22 5/18/201009 2ND FL NORTH, NE ROOM 0 0 0TEXTURED CEILING

MATERIAL

FC571-09-23 5/18/201009 2ND FL SOUTH, SW ROOM 0 0 0TEXTURED CEILING

MATERIAL

FC571-09-24 5/18/201009 3RD FL SOUTH, SE ROOM 0 0 0TEXTURED CEILING

MATERIAL

FC571-09-25 5/18/201009 3RD FL NORTH, NW ROOM 0 0 0TEXTURED CEILING

MATERIAL

FC525-10-10 9/20/200510 1ST FL CNTR HALL 0 0 012" CREAM FLOOR TILE

AND ADHESIVE

FC555-11-10 9/20/200511 DOORS 0 0 0EXTERIOR CAULKING, GRAY

FC571-11-20 5/18/201011 2ND FL SOUTH, EAST MR

DOOR

0 0 0EXTERIOR CAULKING, GRAY

FC571-11-21 5/18/201011 2ND FL EAST CNTR BRICK

JOINT

0 0 0EXTERIOR CAULKING, GRAY

Thursday, March 19, 2026 Page 6 of 8Print Date:

HA Sample Location Chr

Amo

Oth

Description

FC571-11-22 5/18/201011 3RD FL EAST CNTR BRICK

JOINT

0 0 0EXTERIOR CAULKING, GRAY

FC571-12-10 9/20/200512 PIPE CHASE 0 0 0DUCT SEALANT, GRAY

FC571-12-20 5/18/201012 2ND FL SOUTH CHASE,

SOUTH

0 0 0DUCT SEALANT, GRAY

FC571-12-21 5/18/201012 3RD FL NORTH CHASE,

NORTH

0 0 0DUCT SEALANT, GRAY

FC571-20-20 5/18/201020 1ST FL SOUTH MECH RM 0 0 0DUCT SEALANT, TAN

FC571-20-21 5/18/201020 3RD FL NORTH MECH RM 0 0 0DUCT SEALANT, TAN

FC571-21-20 5/18/201021 1ST FL SOUTH MECH RM 0 0 0DUCT SEALANT, WHITE

FC571-21-21 5/18/201021 3RD FL NORTH MECH RM 0 0 0DUCT SEALANT, WHITE

FC571-22-20 5/18/201022 1ST FL SOUTH MECH RM 0 0 0CLOTH EXPANSION

JOINT MATERIAL, THIN

BLACK

FC571-22-21 5/18/201022 3RD FL NORTH MECH RM 0 0 0CLOTH EXPANSION

JOINT MATERIAL, THIN

BLACK

FC571-23-20 5/18/201023 1ST FL SOUTH, SE ROOM 0 0 0DRYWALL AND JOINT

MATERIAL

FC571-23-21 5/18/201023 1ST FL NORTH, NW ROOM 0 0 0DRYWALL AND JOINT

MATERIAL

FC571-23-22 5/18/201023 2ND FL NORTH, NE ROOM 0 0 0DRYWALL AND JOINT

MATERIAL

FC571-23-23 5/18/201023 2ND FL SOUTH, SW ROOM 0 0 0DRYWALL AND JOINT

MATERIAL

FC571-23-24 5/18/201023 3RD FL SOUTH, SE ROOM 0 0 0DRYWALL AND JOINT

MATERIAL

FC571-23-25 5/18/201023 3RD FL NORTH, NW ROOM 0 0 0DRYWALL AND JOINT

MATERIAL

FC571-24-20 5/18/201024 1ST FL NORTH MECH ROOM 0 0 0LAGGING PAPER ON

FIBERGLASS

FC571-25-00ri13 12/9/201325 N/A 9 9 9ROOFING SEALANT, GRAY

FC571-25-00ri16 6/9/201625 N/A 9 9 9ROOFING SEALANT, GRAY

FC571-25-00ri19 9/18/201925 N/A 9 9 9ROOFING SEALANT, GRAY

Thursday, March 19, 2026 Page 7 of 8Print Date:

HA Sample Location Chr

Amo

Oth

Description

FC571-25-00ri23 3/28/202325 N/A 9 9 9ROOFING SEALANT, GRAY

FC571-25-20 5/18/201025 ATTIC/ ROOF, NORTH CNTR 0 0 0ROOFING SEALANT,

GRAY

FC571-25-21 5/18/201025 ATTIC/ ROOF, SOUTH CNTR 5 0 0ROOFING SEALANT,

GRAY

FC571-26-20 5/18/201026 ATTIC/ ROOF, NORTH CNTR 0 0 0ROOFING SEALANT,

BLACK

FC571-26-21 5/18/201026 ATTIC/ ROOF, SOUTH CNTR 0 0 0ROOFING SEALANT,

BLACK

FC571-27-20 5/18/201027 ATTIC/ ROOF, NORTH CNTR 0 0 0TAR PAPER, BLACK

FC571-27-21 5/18/201027 ATTIC/ ROOF, SOUTH CNTR 0 0 0TAR PAPER, BLACK

FC571-27-40 9/18/201927 ATTIC, NO. CNTR

UNDERLAYMENT

0 0 0TAR PAPER, BLACK

FC571-28-20 5/18/201028 ATTIC/ ROOF, NORTH CNTR 0 0 0BUILT-UP ROOFING BLACK

FC571-28-21 5/18/201028 ATTIC/ ROOF, SOUTH CNTR 0 0 0BUILT-UP ROOFING BLACK

FC571-30-00ri16 6/9/201630 N/A 9 9 9RESIDUAL MASTIC BLACK

FC571-30-00ri19 9/18/201930 N/A; 2ND FL NE 9 9 9RESIDUAL MASTIC BLACK

FC571-30-00ri23 3/28/202330 N/A 9 9 9RESIDUAL MASTIC BLACK

FC571-30-30 12/9/201330 2ND FL, NE ROOM DOORWAY 2 0 0RESIDUAL MASTIC BLACK

FC571-30-40 9/18/201930 2ND FL, NO. EAST CNTR 0 0 0RESIDUAL MASTIC BLACK

FC571-30-41 9/18/201930 3RD FL, SO. WEST CNTR 0 0 0RESIDUAL MASTIC BLACK

Thursday, March 19, 2026 Page 8 of 8Print Date: