The report identifies non-friable asbestos-containing materials (ACM) present in the building, specifically roofing materials located in the attic from the previous roof system with membrane underlay on concrete. Four instances of roofing material ACM have been documented: 11,186 square feet throughout the attic (identified 6/23/2009), and 2,016 square feet at the perimeter (identified 8/21/2012, 9/15/2014, and 2/6/2018). No friable ACM has been identified. The report includes extensive documentation of tested non-ACM or removed materials from various locations within the building, including floor tiles, caulking, pipe insulation sealants, ceiling tiles, drywall, and various other building components. All 73 samples collected and tested between 2006 and 2022 show no asbestos content (0% chrysotile, amosite, and other asbestos types), with the exception of roofing material samples showing 6-9% chrysotile content. The building's asbestos program manager is located at 910-451-5837, and the Camp Lejeune Asbestos Program Manager maintains copies of the full survey. Building occupants are instructed to avoid disturbance of ACM and report any damage, dust, or debris to the asbestos program manager.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ASBESTOS INSPECTION REPORT of:
Building # HP51
MCB CAMP LEJEUNE
Tuesday, November 4, 2025
Print Date
Tuesday, November 4, 2025 Page 1 of 8Print Date:
INSPECTION SUMMARY
BLDG #:
OCCUPANT:
YEAR BUILT:
BUILDING COMMENTS:
HP51
BEQ
HAZ RANK 3/GREEN [DEC2022]
ACM ROOFING
DEC2022
NO CHANGE
FEB2018
ACM REMAINS
SEPT2014
OLD ACM ROOF REMAINS IN ATTIC; SOUTHWEST ROOF STILL OPEN TO ELEMENTS, ROT OCCURING
AUG/DEC2012
MASTIC REMOVED, OLD ROOF MATERIALS REMAIN, PERIMETER ONLY
JUN09
ACM INCLUDES:
RESIDUAL FLOOR TILE MASTIC, BLACK
ROOFING MATERIAL, OLD UNDERLAYMENT
INSPECT AUG06
ACM IDENTIFIED INCLUDES:
RESIDUAL FLOOR TILE MASTIC, BLACK
ASBESTOS MANAGER: 910-451-5837
Friable ACM(s) identified
Non-friable ACM(s) identified
NOTICE: The following asbestos-containing materials have been identified in this structure. Refer to survey findings for additional information or contact the Asbestos Program Manager. Please note ACM that is intact and undisturbed is not considered a significant health hazard to building occupants.
DESCRIPTION LOCATION Date Quantity
DESCRIPTION LOCATION Date Quantity
No friable ACM records found in database
NOTIFICATION OF ACM IN BUILDING
ROOFING MATERIAL, 11,186 SFTHROUGHOUT ATTIC (PREVIOUS ROOF)
MEMBRANE UNDERLAY ON CONCRETE
6/23/2009
ROOFING MATERIAL, 2,016 SFATTIC (PREVIOUS ROOF) MEMBRANE
UNDERLAY ON CONCRETE AT
PERIMETER
8/21/2012
ROOFING MATERIAL, 2,016 SFATTIC (PREVIOUS ROOF) MEMBRANE
UNDERLAY ON CONCRETE AT
PERIMETER
9/15/2014
ROOFING MATERIAL, 2,016 SFTHROUGHOUT ATTIC (PREVIOUS ROOF)
MEMBRANE UNDERLAY ON CONCRETE
2/6/2018
Tuesday, November 4, 2025 Page 2 of 8Print Date:
Tested Non ACM or REMOVED Materials
DESCRIPTION LOCATION Date
ROOFING MATERIAL, 2,016 SFTHROUGHOUT ATTIC (PREVIOUS ROOF)
MEMBRANE UNDERLAY ON CONCRETE
12/14/2022
EXTERIOR CAULKING, DOORS 8/3/2006
PIPE INSULATION SEALANT LAUNDRY ROOM PIPING, E/W PIPE
CHASES THROUGHOUT
8/3/2006
4" VINYL BASE AND ADHESIVE THROUGHOUT TILED AREAS OF DORM
ROOMS
8/3/2006
2'x2' CEILING TILE, THROUGHOUT OFFICES, COMMON
CENTRAL AREAS
8/3/2006
12" BEIGE w/BROWN FLOOR TILE AND
ADHESIVE
LOUNGES AND DORM ROOMS 8/3/2006
DRYWALL AND JOINT MATERIAL WALLS THROUGHOUT CENTRAL
COMMON AREAS AND DORM ROOM
HEADS
8/3/2006
4" VINYL BASE AND ADHESIVE FIRST FLOOR JANITORS CLOSET 8/3/2006
TEXTURED CEILING MATERIAL DORM ROOMS AND OFFICES
THROUGHOUT
8/3/2006
ROOFING SEALANT, BLACK ATTIC (OLD ROOFING SYSTEM),
PERIMETER FLASHING EDGE
6/23/2009
WALLBOARD/ SHEATHING BEHIND OLD VANITIY (IDENTIFIED IN
MECHANICAL ROOM CONVERSIONS)
w/WALLPAPER AND DRYWALL
6/23/2009
LINOLEUM AND ADHESIVE, DORM ROOMS THROUGHOUT 6/23/2009
DRYWALL AND JOINT MATERIAL MECHANICAL ROOMS (DEBRIS FROM
OLD HEAD RIP-OUTS FOR MECHANICAL
ROOM CONVERSIONS)
8/3/2006
FLOOR LEVELING COMPOUND THIRD FLOOR LOUNGE (UNABLE TO
DETERMINE EXACT EXTENT DUE TO
FLOOR COVERINGS, TYPICALLY AT
THRESHOLDS AND CORNERS)
6/23/2009
EXTERIOR CAULKING, ATTIC (OLD ROOFING SYSTEM),
PERIMETER METAL FLASHING EDGE
6/23/2009
RESIDUAL MASTIC FIRST FLOOR CENTER CORRIDOR 6/23/2009
TAR PAPER, BLACK THROUGHOUT ATTIC (PREVIOUS ROOF)
MEMBRANE UNDERLAY ON CONCRETE
w/SEALANT
6/23/2009
ROOFING SEALANT, SILVER ATTIC CENTER, ROOF ACCESS HATCH
FLASHING
6/23/2009
FIBROUS DEBRIS FIRST FLOOR WEST OFFICES OVERHEAD 6/23/2009
INTERIOR CAULKING, ELECTRICAL ROOM DOOR 8/3/2006
INTERIOR CAULKING, DUCT FLASHING AT WALLS IN
MECHANCIAL ROOMS AND CHASES
8/3/2006
Tuesday, November 4, 2025 Page 3 of 8Print Date:
ACM only presents a health hazard when asbestos fibers are airborne and inhaled.
Avoid disturbance which will release fibers. The presence of asbestos does not constitute a health hazard.
HEALTH ASPECTS:
Do not disturb or cause damage to ACM. Do not sand, grind or abrade materials or cause damage with any type of equipment.
CONDITIONS TO AVOID:
Report any damage, dust or debris that may come from ACM or suspect ACM, or any change in the condition of materials, or accidental disturbance to the Asbestos
Program Manager.
REPORTS OF DAMAGE:
Corrective action initiated to minimize fiber release and protect personnel. RESPONSE ACTION:
ACM will be inspected periodically to evaluate any changes in condition.INSPECTION:
The Camp Lejeune Asbestos Program Manager maintains a copy of the survey for the building.
RECORDKEEPING:
CAMP LEJEUNE Asbestos Program Manager: Phone: (910) 451-5837
DUCT SEALANT, RED MECHANICAL ROOMS AND CHASES AT
DUCT PENETRATIONS (FIREWALLS)
8/3/2006
PIPE INSULATION SEALANT MECHANICAL ROOM PIPING AT HVAC
UNITS
8/3/2006
EXTERIOR CAULKING, EXTERIOR WALL BRICK JOINTS 8/3/2006
FOIL BACKED TAPE FIBERGLASS PIPE WRAP IN CHASES 6/23/2009
WALLBOARD MECHANICAL ROOMS (DEBRIS FROM
OLD HEAD RIP-OUTS FOR MECHANICAL
ROOM CONVERSIONS)
8/3/2006
12" BEIGE w/BROWN FLOOR TILE AND
ADHESIVE
FIRST FLOOR LOUNGE, PATCHES OF
RESIDUAL UNDER TILE
6/23/2009
DRYWALL AND JOINT MATERIAL DORM ROOM HEAD AREAS (WALLS
AND CEILINGS);
MECHANICAL ROOMS (DEBRIS FROM
OLD HEAD CONVERSIONS)
6/23/2009
PIPE INSULATION SEALANT MECHANICAL ROOM PIPING AT HVAC
UNITS
6/23/2009
EXTERIOR CAULKING, DOORS 6/23/2009
DUCT SEALANT, RED MECHANICAL ROOMS AND CHASES AT
DUCT PENETRATIONS (FIREWALLS)
6/23/2009
INTERIOR CAULKING, DUCT FLASHING AT WALLS IN
MECHANCIAL ROOMS AND CHASES
6/23/2009
INTERIOR CAULKING, DOORS THROUGHOUT, BASE COVE
RESIDUAL IN MECHANICAL ROOMS
6/23/2009
Tuesday, November 4, 2025 Page 4 of 8Print Date:
SAMPLES COLLECTED
Sample Sample
Date
HA Sample Location Chr
Amo
Oth
Description
HP51-01-01 8/3/200601 1ST FLOOR 4 0 012" BEIGE w/BROWN
FLOOR TILE AND
ADHESIVE
HP51-01-02 8/3/200601 ROOM 207 0 0 012" BEIGE w/BROWN
FLOOR TILE AND
ADHESIVE
HP51-01-02tem 8/3/200601 ROOM 207 0 0 012" BEIGE w/BROWN
FLOOR TILE AND
ADHESIVE
HP51-01-03 8/3/200601 ROOM 200 0 0 012" BEIGE w/BROWN
FLOOR TILE AND
ADHESIVE
HP51-01-04 8/3/200601 SOUTH CNTR OFFICE 0 0 012" BEIGE w/BROWN
FLOOR TILE AND
ADHESIVE
HP51-01-10 6/23/200901 1ST FL WEST OFFICE, SW 0 0 012" BEIGE w/BROWN
FLOOR TILE AND
ADHESIVE
HP51-01-10tem 6/23/200901 1ST FL WEST OFFICE, SW 0 0 012" BEIGE w/BROWN
FLOOR TILE AND
ADHESIVE
HP51-01-11 6/23/200901 1ST FL NW DORM RM 0 0 012" BEIGE w/BROWN
FLOOR TILE AND
ADHESIVE
HP51-01-12 6/23/200901 2ND FL LOUNGE 0 0 012" BEIGE w/BROWN
FLOOR TILE AND
ADHESIVE
HP51-01-12tem 6/23/200901 2ND FL LOUNGE 0 0 012" BEIGE w/BROWN
FLOOR TILE AND
ADHESIVE
HP51-01-13 6/23/200901 3RD FL LOUNGE 0 0 012" BEIGE w/BROWN
FLOOR TILE AND
ADHESIVE
HP51-01-13tem 6/23/200901 3RD FL LOUNGE 0 0 012" BEIGE w/BROWN
FLOOR TILE AND
ADHESIVE
HP51-02-01 8/3/200602 1ST FL LOUNGE, NE 0 0 04" VINYL BASE AND
ADHESIVE
BROWN
HP51-03-01 8/3/200603 1ST FL LOUNGE, NE 0 0 02'x2' CEILING TILE, HP51-04-01 8/3/200604 1ST FL LOUNGE, WEST 0 0 0DRYWALL AND JOINT
MATERIAL
Tuesday, November 4, 2025 Page 5 of 8Print Date:
HA Sample Location Chr
Amo
Oth
Description
HP51-05-01 8/3/200605 1ST FL CNTR JANITOR 0 0 04" VINYL BASE AND
ADHESIVE
BLACK
HP51-06-01 8/3/200606 1ST FL LAUNDRY 0 0 0PIPE INSULATION
SEALANT
WHITE
HP51-07-01 8/3/200607 1ST FL SOUTH 0 0 0EXTERIOR CAULKING, GRAY
HP51-07-02 8/3/200607 3RD FL NE MR 0 0 0EXTERIOR CAULKING, GRAY
HP51-07-10 6/23/200907 1ST FL WEST OFFICES, SOUTH 0 0 0EXTERIOR CAULKING, GRAY
HP51-08-01 8/3/200608 1ST FL NORTH ELECTRIC 0 0 0INTERIOR CAULKING, WHITE
HP51-08-10 6/23/200908 1ST FL NE MR BASE 0 0 0INTERIOR CAULKING, WHITE
HP51-08-11 6/23/200908 3RD FL SW DORM RM DOOR 0 0 0INTERIOR CAULKING, WHITE
HP51-08-12 6/23/200908 3RD FL NE MR BASE 0 0 0INTERIOR CAULKING, WHITE
HP51-09-01 8/3/200609 1ST FL NE MR 0 0 0INTERIOR CAULKING, WHITE
HP51-09-02 8/3/200609 3RD FL NE MR 0 0 0INTERIOR CAULKING, WHITE
HP51-09-10 6/23/200909 2ND FL NW MR 0 0 0INTERIOR CAULKING, WHITE
HP51-10-01 8/3/200610 1ST FL NE MR 0 0 0DUCT SEALANT, RED
HP51-10-02 8/3/200610 3RD FL NE MR 0 0 0DUCT SEALANT, RED
HP51-10-10 6/23/200910 1ST FL NE MR 0 0 0DUCT SEALANT, RED
HP51-10-11 6/23/200910 2ND FL NE MR 0 0 0DUCT SEALANT, RED
HP51-11-01 8/3/200611 1ST FL NE MR 0 0 0PIPE INSULATION
SEALANT
WHITE
HP51-11-02 8/3/200611 3RD FL NE MR 0 0 0PIPE INSULATION
SEALANT
WHITE
HP51-11-10 6/23/200911 3RD FL NE MR 0 0 0PIPE INSULATION
SEALANT
WHITE
HP51-12-01 8/3/200612 1ST FL WEST END 0 0 0EXTERIOR CAULKING, GRAY
HP51-12-02 8/3/200612 3RD FL EAST END 0 0 0EXTERIOR CAULKING, GRAY
HP51-13-01 8/3/200613 1ST FL NW MR 0 0 0DRYWALL AND JOINT
MATERIAL
HP51-13-02 8/3/200613 3RD FL NE MR 0 0 0DRYWALL AND JOINT
MATERIAL
Tuesday, November 4, 2025 Page 6 of 8Print Date:
HA Sample Location Chr
Amo
Oth
Description
HP51-13-10 6/23/200913 1ST FL SE DORM RM CEILING 0 0 0DRYWALL AND JOINT
MATERIAL
HP51-13-11 6/23/200913 1ST FL NE DORM RM CEILING 0 0 0DRYWALL AND JOINT
MATERIAL
HP51-13-12 6/23/200913 2ND FL SW DORM RM WALL 0 0 0DRYWALL AND JOINT
MATERIAL
HP51-13-13 6/23/200913 3RD FL NW MR WALL 0 0 0DRYWALL AND JOINT
MATERIAL
HP51-13-14 6/23/200913 3RD FL SW DORM RM WALL 0 0 0DRYWALL AND JOINT
MATERIAL
HP51-14-01 8/3/200614 1ST FL NW MR 0 0 0WALLBOARD
HP51-15-01 8/3/200615 2ND FL 200 0 0 0TEXTURED CEILING
MATERIAL
HP51-15-02 8/3/200615 2ND FL 207 0 0 0TEXTURED CEILING
MATERIAL
HP51-15-03 8/3/200615 1ST FL SOUTH CNTR LINEN 0 0 0TEXTURED CEILING
MATERIAL
HP51-20-10 6/23/200920 1ST FL WEST OFFICES, CNTR 0 0 0FIBROUS DEBRIS WHITE
HP51-21-10 6/23/200921 1ST FL CNTR CORRIDOR, SE 0 0 0RESIDUAL MASTIC BLACK
HP51-22-10 6/23/200922 1ST FL SE DORM RM 0 0 0LINOLEUM AND
ADHESIVE,
BEIGE w/TAN
HP51-22-11 6/23/200922 1ST FL NE DORM RM 0 0 0LINOLEUM AND
ADHESIVE,
BEIGE w/TAN
HP51-22-12 6/23/200922 2ND FL SW DORM RM 0 0 0LINOLEUM AND
ADHESIVE,
BEIGE w/TAN
HP51-23-10 6/23/200923 1ST FL NW MR 0 0 0WALLBOARD/
SHEATHING
HP51-24-10 6/23/200924 2ND FL SW DORM RM 0 0 0FOIL BACKED TAPE
HP51-24-11 6/23/200924 3RD FL SW DORM RM 0 0 0FOIL BACKED TAPE
HP51-25-10 6/23/200925 3RD FL CNTR LOUNGE 0 0 0FLOOR LEVELING
COMPOUND
GRAY
HP51-26-10 6/23/200926 ATTIC, WEST CNTR 0 0 0EXTERIOR CAULKING, WHITE
HP51-26-11 6/23/200926 ATTIC, EAST CNTR 0 0 0EXTERIOR CAULKING, WHITE
HP51-27-10 6/23/200927 ATTIC, WEST END CNTR 0 0 0ROOFING SEALANT,
BLACK
Tuesday, November 4, 2025 Page 7 of 8Print Date:
HA Sample Location Chr
Amo
Oth
Description
HP51-27-11 6/23/200927 ATTIC, EAST END CNTR 0 0 0ROOFING SEALANT,
BLACK
HP51-28-00ri12 8/21/201228 N/A 9 9 9ROOFING MATERIAL, BLACK
HP51-28-00ri14 9/15/201428 N/A 9 9 9ROOFING MATERIAL, BLACK
HP51-28-00ri17 2/6/201828 N/A 9 9 9ROOFING MATERIAL, BLACK
HP51-28-00ri23 12/14/202228 N/A 9 9 9ROOFING MATERIAL, BLACK
HP51-28-10 6/23/200928 ATTIC, WEST END CNTR 6 0 0ROOFING MATERIAL, BLACK
HP51-28-11 6/23/200928 ATTIC, EAST END CNTR 0 0 0ROOFING MATERIAL, BLACK
HP51-28-20 12/7/201228 ATTIC, EAST CNTR MAIN
MEMBRANE
0 0 0ROOFING MATERIAL, BLACK
HP51-28-21 12/7/201228 ATTIC, WEST CNTR MAIN
MEMBRANE
0 0 0ROOFING MATERIAL, BLACK
HP51-29-10 6/23/200929 ATTIC, WEST END CNTR 0 0 0TAR PAPER, BLACK
HP51-29-11 6/23/200929 ATTIC, EAST END CNTR 0 0 0TAR PAPER, BLACK
HP51-30-10 6/23/200930 ATTIC CNTR HATCH 0 0 0ROOFING SEALANT,
SILVER
Tuesday, November 4, 2025 Page 8 of 8Print Date: