HP 255 ACM REPORT.pdf

PDF 313 KB Posted

Attached to
ROOF REPAIRS BUILDINGS HP51, HP53, HP55, HP57, HP255, AND HP265
Solicitation number
N4008526R9016
Issued by

About this file

This is an Asbestos Inspection Report for Building HP255 (a Bachelor Enlisted Quarters facility) located at MCB Camp Lejeune, dated March 12, 2026. The building was constructed in 1983 and has a Hazard Rank of 3/GREEN as of June 2023.

The report documents asbestos-containing materials (ACM) identified in the structure through inspections conducted between February 2006 and June 2023. No friable ACM has been found in the database. Non-friable ACM identified includes miscellaneous sealant (vapor barrier/sealant between CMU block and exterior brick walls, mostly non-asbestos) totaling 21,000 square feet, documented on September 18, 2014, February 8, 2018, and June 7, 2023. The report notes that major renovations occurred in September 2014, during which ACM flooring was removed while ACM roofing remains. Numerous materials have been tested and confirmed as non-ACM or removed, including floor tiles, drywall, ceiling tiles, caulking, pipe insulation, roofing materials, and sealants tested between February 2006 and September 2014. The report emphasizes that intact and undisturbed ACM does not constitute a significant health hazard to building occupants. Building occupants are instructed to avoid disturbing or damaging ACM, avoid sanding or grinding materials, and report any damage or debris to the Asbestos Program Manager at 910-451-5837. ACM will be inspected periodically to evaluate changes in condition, with corrective action initiated to minimize fiber release and protect personnel if disturbance occurs.

View the file

Other files

Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ASBESTOS INSPECTION REPORT of:

Building # HP255

MCB CAMP LEJEUNE

Thursday, March 12, 2026

Print Date

Thursday, March 12, 2026 Page 1 of 11Print Date:

INSPECTION SUMMARY

BLDG #:

OCCUPANT:

YEAR BUILT:

BUILDING COMMENTS:

HP255

BEQ

HAZ RANK 3/GREEN [JUN2023]

SEALANT WITHIN WALLS

JUN2023

ACM REMAINS, NAX

SEPT2014

MAJOR RENOVATIONS, PVS. ACM FLOORING REMOVED; ACM ROOFING REMAINS; ADDL SAMPLING, ACM INCLUDES:

MISC. SEALANT, BLACK (TWEEN WALLS, PVS. NAX)

AUG2012

LTD. RENOVATION IN CENTER SECTION (TILE REMOVED); OTHER PVS. ACM REMAINS, LITTLE CHANGE

JUL09

PVS. ACM CONFIRMED TO REMAIN, PLM/TEM TESTING OF TILES (NON ACM), ADDL SAMPLINGS, ACM INCLUDES:

TILE MASTIC

ROOF FLASHINGS/ TAR SEALANTS

INSPECT FEB06

ACM IDENTIFIED INCLUDS:

FLOOR TILE MASTIC

ROOFING MATERIAL, TAR

ASBESTOS MANAGER: 910-451-5837

Friable ACM(s) identified

Non-friable ACM(s) identified

NOTICE: The following asbestos-containing materials have been identified in this structure. Refer to survey findings for additional information or contact the Asbestos Program Manager. Please note ACM that is intact and undisturbed is not considered a significant health hazard to building occupants.

DESCRIPTION LOCATION Date Quantity

DESCRIPTION LOCATION Date Quantity

No friable ACM records found in database

NOTIFICATION OF ACM IN BUILDING

MISCELLANEOUS SEALANT 21,000 SFVAPOR BARRIER/ SEALANT BETWEEN

CMU BLOCK AND EXTERIOR BRICK

WALLS (MOSTLY NAX)- UNCOVERED

BY RENOVATIONS

9/18/2014

MISCELLANEOUS SEALANT 21,000 SFVAPOR BARRIER/ SEALANT BETWEEN

CMU BLOCK AND EXTERIOR BRICK

WALLS (MOSTLY NAX)- UNCOVERED

BY RENOVATIONS

2/8/2018

Thursday, March 12, 2026 Page 2 of 11Print Date:

Tested Non ACM or REMOVED Materials

DESCRIPTION LOCATION Date

MISCELLANEOUS SEALANT 21,000 SFVAPOR BARRIER/ SEALANT BETWEEN

CMU BLOCK AND EXTERIOR BRICK

WALLS (MOSTLY NAX)- UNCOVERED

BY RENOVATIONS

6/7/2023

EXTERIOR CAULKING, WINDOWS 2/22/2006

12" GREEN FLOOR TILE AND ADHESIVE SECOND FLOOR CENTER HEAD 2/22/2006

MISCELLANEOUS SEALANT CENTRAL ELECTRICAL ROOMS AND

PIPE CHASES AT CONDUIT/ CABLE

PENETRATIONS

2/22/2006

DRYWALL AND JOINT MATERIAL DORM ROOMS THROUGHOUT 2/22/2006

12" WHITE FLOOR TILE AND ADHESIVE PRIMARY TILE OF DORM ROOMS

THROUGHOUT (SEE ALSO HM10/ 11)

2/22/2006

TEXTURED CEILING MATERIAL DORM ROOMS ON CONCRETE

THROUGHOUT

2/22/2006

PIPE INSULATION PIPE CHASES, LOUNGES, LAUNDRY

ROOMS

2/22/2006

12" BROWN FLOOR TILE AND MASTIC HALLWAY PATCHING 2/22/2006

ROOFING MATERIAL, ROOFING SYSTEM BASE FLASHING

TARS (SEE ALSO HM40)

2/22/2006

DUCT SEALANT, RED CENTRAL PIPE CHASES 2/22/2006

CLOTH EXPANSION JOINT MATERIAL,

THICK

DORM ROOM HVAC UNITS BY HEADS 2/22/2006

2'x2' CEILING TILE, CENTRAL AREA LOUNGES 2/22/2006

2'x4' CEILING TILE, CENTRAL HALLWAY/ CONNECTION

CORRIDORS

2/22/2006

ROOFING SEALANT, BLACK ROOFING SYSTEM PERIMETER

PARAPET WALLS AND FLASHINGS (SEE

ALSO HM18)

7/8/2009

MASTIC ON HVAC DUCT INSULATION, DORM ROOM HVAC UNITS BY HEADS 2/22/2006

EXTERIOR CAULKING, DORM ROOM DOORS 7/8/2009

EXTERIOR CAULKING, BRICK EXPANSION JOINTS (OVER HM35) 7/8/2009

EXTERIOR CAULKING, BRICK EXPANSION JOINTS (UNDER

HM36)

7/8/2009

WINDOW GLAZING MATERIAL THIRD FLOOR LAUNDRY, WINDOW IN

DOOR

7/8/2009

INTERIOR CAULKING, DORM ROOM DOORS AND SINK/

VANITIES

7/8/2009

CARPET ADHESIVE CENTRAL AREA LOUNGES 2/22/2006

BUILT-UP ROOFING TOP LAYER, MAIN ROOFING SYSTEM 7/8/2009

FIBERGLASS INSULATION SEALANT NORTH AND SOUTH MECHANICAL

ROOMS AND CENTRAL PIPE CHASES

2/22/2006

Thursday, March 12, 2026 Page 3 of 11Print Date:

ACM only presents a health hazard when asbestos fibers are airborne and inhaled.

Avoid disturbance which will release fibers. The presence of asbestos does not constitute a health hazard.

HEALTH ASPECTS:

Do not disturb or cause damage to ACM. Do not sand, grind or abrade materials or cause damage with any type of equipment.

CONDITIONS TO AVOID:

FOIL BACKED TAPE PIPE CHASES, MECHANICAL ROOMS,

CENTRAL UTILITY AREAS

THROUGHOUT

7/8/2009

CAPPING INSULATION ON PIPE CHASES, MECHANICAL ROOMS,

CENTRAL UTILITY AREAS

THROUGHOUT

7/8/2009

MISCELLANEOUS SEALANT PIPE CHASES, MECHANICAL ROOMS,

CENTRAL UTILITY AREAS

THROUGHOUT AT PIPE PENETRATIONS

THROUGH WALL

7/8/2009

ROOFING MATERIAL, CHUNKS OF ROOFING MATERIALS

AROUND PERIMETER

7/8/2009

12" BLACK FLOOR TILE AND ADHESIVE CENTRAL AREA LOUNGES (OVER HM11) 2/22/2006

12" WHITE FLOOR TILE AND ADHESIVE CENTRAL AREA LOUNGES (OVER HM11) 2/22/2006

MASTIC ON HVAC DUCT INSULATION, NORTH AND SOUTH MECHANICAL

ROOMS AND CENTRAL PIPE CHASES

2/22/2006

12" WHITE w/ GRAY FLOOR TILE AND

ADHESIVE

CENTRAL HALLWAYS, CONNECTION

CORRIDORS

2/22/2006

12" WHITE FLOOR TILE AND ADHESIVE CENTRAL AREA LOUNGES (UNDER

HM08, 09)

2/22/2006

ROOFING SEALANT, BLACK ROOFING SYSTEM PERIMETER

PARAPET WALLS AND FLASHINGS (SEE

ALSO HM18)

9/18/2014

ROOFING MATERIAL, ROOFING SYSTEM BASE FLASHING

TARS (SEE ALSO HM40)

9/18/2014

12" WHITE FLOOR TILE AND ADHESIVE PRIMARY TILE OF DORM ROOMS

THROUGHOUT (SEE ALSO HM10/ 11)

7/8/2009

DRYWALL AND JOINT MATERIAL DORM ROOMS THROUGHOUT 7/8/2009

12" WHITE FLOOR TILE AND ADHESIVE CENTRAL AREA LOUNGES (OVER HM11) 7/8/2009

12" BLACK FLOOR TILE AND ADHESIVE CENTRAL AREA LOUNGES (OVER HM11) 7/8/2009

12" WHITE FLOOR TILE AND ADHESIVE CENTRAL AREA LOUNGES (UNDER

HM08, 09)

7/8/2009

12" WHITE w/ GRAY FLOOR TILE AND

ADHESIVE

CENTRAL HALLWAYS, CONNECTION

CORRIDORS

7/8/2009

ROOFING MATERIAL, ROOFING SYSTEM BASE FLASHING

TARS (SEE ALSO HM40)

7/8/2009

12" WHITE FLOOR TILE AND ADHESIVE PRIMARY TILE OF DORM ROOMS

THROUGHOUT (SEE ALSO HM10/ 11)

8/22/2012

ROOFING MATERIAL, ROOFING SYSTEM BASE FLASHING

TARS (SEE ALSO HM40)

8/22/2012

ROOFING SEALANT, BLACK ROOFING SYSTEM PERIMETER

PARAPET WALLS AND FLASHINGS (SEE

ALSO HM18)

8/22/2012

Thursday, March 12, 2026 Page 4 of 11Print Date:

Do not disturb or cause damage to ACM. Do not sand, grind or abrade materials or cause damage with any type of equipment.

Report any damage, dust or debris that may come from ACM or suspect ACM, or any change in the condition of materials, or accidental disturbance to the Asbestos

Program Manager.

REPORTS OF DAMAGE:

Corrective action initiated to minimize fiber release and protect personnel. RESPONSE ACTION:

ACM will be inspected periodically to evaluate any changes in condition.INSPECTION:

The Camp Lejeune Asbestos Program Manager maintains a copy of the survey for the building.

RECORDKEEPING:

CAMP LEJEUNE Asbestos Program Manager: Phone: (910) 451-5837

Thursday, March 12, 2026 Page 5 of 11Print Date:

SAMPLES COLLECTED

Sample Sample

Date

HA Sample Location Chr

Amo

Oth

Description

HP255-01-01 2/22/200601 1ST FL SOUTH WING, SE RM

0 0 0TEXTURED CEILING

MATERIAL

HP255-01-02 2/22/200601 1ST FL NORTH WING, SE RM

0 0 0TEXTURED CEILING

MATERIAL

HP255-01-03 2/22/200601 2ND FL NORTH WING, NE RM

0 0 0TEXTURED CEILING

MATERIAL

HP255-01-04 2/22/200601 2ND FL NORTH WING, SE RM

0 0 0TEXTURED CEILING

MATERIAL

HP255-01-05 2/22/200601 3RD FL NORTH WING, SW RM

0 0 0TEXTURED CEILING

MATERIAL

HP255-01-06 2/22/200601 3RD FL SOUTH WING, NW RM

0 0 0TEXTURED CEILING

MATERIAL

HP255-01-07 2/22/200601 3RD FL SOUTH WING, NW RM

0 0 0TEXTURED CEILING

MATERIAL

HP255-02-01 2/22/200602 1ST FL SOUTH WING, SE RM

0 0 0DRYWALL AND JOINT

MATERIAL

HP255-02-02 2/22/200602 1ST FL NORTH WING, SE RM

0 0 0DRYWALL AND JOINT

MATERIAL

HP255-02-03 2/22/200602 2ND FL NORTH WING, NE RM

0 0 0DRYWALL AND JOINT

MATERIAL

HP255-02-04 2/22/200602 2ND FL NORTH WING, SE RM

0 0 0DRYWALL AND JOINT

MATERIAL

HP255-02-05 2/22/200602 3RD FL NORTH WING, SW RM

0 0 0DRYWALL AND JOINT

MATERIAL

HP255-02-10 7/8/200902 1ST FL NORTH WING, EAST

CNTR RM

0 0 0DRYWALL AND JOINT

MATERIAL

HP255-02-11 7/8/200902 2ND FL SOUTH WING, EAST

CNTR RM

0 0 0DRYWALL AND JOINT

MATERIAL

HP255-02-12 7/8/200902 3RD FL NORTH WING, EAST

CNTR RM

0 0 0DRYWALL AND JOINT

MATERIAL

HP255-03-00ri12 8/22/201203 N/A 9 9 912" WHITE FLOOR TILE

AND ADHESIVE

w/BROWN STREAKS

HP255-03-01 2/22/200603 1ST FL SOUTH WING, SE RM

0 0 012" WHITE FLOOR TILE

AND ADHESIVE

w/BROWN STREAKS

HP255-03-01tem 2/22/200603 1ST FL SOUTH WING, SE RM

0.1 0 012" WHITE FLOOR TILE

AND ADHESIVE

w/BROWN STREAKS

Thursday, March 12, 2026 Page 6 of 11Print Date:

HA Sample Location Chr

Amo

Oth

Description

HP255-03-02 2/22/200603 2ND FL NORTH WING, NE RM

3 0 012" WHITE FLOOR TILE

AND ADHESIVE

w/BROWN STREAKS

HP255-03-03 2/22/200603 3RD FL NORTH WING, SW RM

3 0 012" WHITE FLOOR TILE

AND ADHESIVE

w/BROWN STREAKS

HP255-03-10 7/8/200903 1ST FL NORTH WING, SE RM 5 0 012" WHITE FLOOR TILE

AND ADHESIVE

w/BROWN STREAKS

HP255-03-10tem 7/8/200903 1ST FL NORTH WING, SE RM 0 0 012" WHITE FLOOR TILE

AND ADHESIVE

w/BROWN STREAKS

HP255-03-11 7/8/200903 1ST FL SOUTH WING, SW RM 3 0 012" WHITE FLOOR TILE

AND ADHESIVE

w/BROWN STREAKS

HP255-03-12 7/8/200903 2ND FL SOUTH WING, EAST

CNTR RM

5 0 012" WHITE FLOOR TILE

AND ADHESIVE

w/BROWN STREAKS

HP255-03-13 7/8/200903 2ND FL CNTR LOUNGE 0 0 012" WHITE FLOOR TILE

AND ADHESIVE

w/BROWN STREAKS

HP255-03-14 7/8/200903 2ND FL NORTH WING, NW RM 3 0 012" WHITE FLOOR TILE

AND ADHESIVE

w/BROWN STREAKS

HP255-03-15 7/8/200903 3RD FL NORTH WING, EAST

CNTR RM

3 0 012" WHITE FLOOR TILE

AND ADHESIVE

w/BROWN STREAKS

HP255-03-16 7/8/200903 3RD FL SOUTH WING, WEST

CNTR RM

2 0 012" WHITE FLOOR TILE

AND ADHESIVE

w/BROWN STREAKS

HP255-04-01 2/22/200604 2ND FL NORTH WING, NE RM

0 0 0MASTIC ON HVAC DUCT

INSULATION,

YELLOW

HP255-04-02 2/22/200604 2ND FL NORTH WING, NE RM

0 0 0MASTIC ON HVAC DUCT

INSULATION,

YELLOW

HP255-05-01 2/22/200605 2ND FL NORTH WING, NE RM

0 0 0CLOTH EXPANSION

JOINT MATERIAL, THICK

HP255-05-02 2/22/200605 3RD FL NORTH WING, SW RM

0 0 0CLOTH EXPANSION

JOINT MATERIAL, THICK

HP255-06-01 2/22/200606 1ST FL LOUNGE 0 0 02'x2' CEILING TILE, HP255-06-02 2/22/200606 2ND FL LOUNGE 0 0 02'x2' CEILING TILE, HP255-07-01 2/22/200607 1ST FL HALLWAY 0 0 02'x4' CEILING TILE, HP255-07-02 2/22/200607 2ND FL HALLWAY 0 0 02'x4' CEILING TILE, HP255-08-01 2/22/200608 1ST FL LOUNGE 0 0 012" BLACK FLOOR TILE

AND ADHESIVE

HP255-08-02 2/22/200608 1ST FL LOUNGE 0 0 012" BLACK FLOOR TILE

AND ADHESIVE

Thursday, March 12, 2026 Page 7 of 11Print Date:

HA Sample Location Chr

Amo

Oth

Description

HP255-08-10 7/8/200908 1ST FL CNTR LOUNGE 0 0 012" BLACK FLOOR TILE

AND ADHESIVE

HP255-09-01 2/22/200609 1ST FL LOUNGE 0 0 012" WHITE FLOOR TILE

AND ADHESIVE

HP255-09-02 2/22/200609 1ST FL LOUNGE 0 0 012" WHITE FLOOR TILE

AND ADHESIVE

HP255-09-10 7/8/200909 1ST FL CNTR LOUNGE 0 0 012" WHITE FLOOR TILE

AND ADHESIVE

HP255-10-00ri08 7/8/200910 N/A 9 9 912" WHITE w/ GRAY

FLOOR TILE AND

ADHESIVE

HP255-10-01 2/22/200610 1ST FLOOR HALLWAY 0 0 012" WHITE w/ GRAY

FLOOR TILE AND

ADHESIVE

HP255-10-01tem 2/22/200610 1ST FLOOR HALLWAY 0.09 0 012" WHITE w/ GRAY

FLOOR TILE AND

ADHESIVE

HP255-10-02 2/22/200610 2ND FLOOR HALL 2 0 012" WHITE w/ GRAY

FLOOR TILE AND

ADHESIVE

HP255-11-01 2/22/200611 1ST FL NORTH WING, SE RM

0 0 012" WHITE FLOOR TILE

AND ADHESIVE

HP255-11-01tem 2/22/200611 1ST FL NORTH WING, SE RM

0.11 0 012" WHITE FLOOR TILE

AND ADHESIVE

HP255-11-02 2/22/200611 1ST FLOOR LOUNGE 3 0 012" WHITE FLOOR TILE

AND ADHESIVE

HP255-11-10 7/8/200911 1ST FL CNTR LOUNGE 5 0 012" WHITE FLOOR TILE

AND ADHESIVE

HP255-11-11 7/8/200911 2ND FL CNTR LOUNGE 3 0 012" WHITE FLOOR TILE

AND ADHESIVE

HP255-12-01 2/22/200612 1ST FL SOUTH WING, NW

WINDOW

0 0 0EXTERIOR CAULKING, GRAY

HP255-12-02 2/22/200612 3RD FL SOUTH WING, NE

WINDOW

0 0 0EXTERIOR CAULKING, GRAY

HP255-13-01 2/22/200613 1ST FL LOUNGE 0 0 0PIPE INSULATION YELLOW FIBERGLASS

HP255-13-02 2/22/200613 2ND FL CNTR LAUNDRY 0 0 0PIPE INSULATION YELLOW FIBERGLASS

HP255-13-03 2/22/200613 1ST FL SOUTH CHASE, NORTH 0 0 0PIPE INSULATION YELLOW FIBERGLASS

HP255-14-01 2/22/200614 2ND FLOOR HEAD 0 0 012" GREEN FLOOR TILE

AND ADHESIVE

Thursday, March 12, 2026 Page 8 of 11Print Date:

HA Sample Location Chr

Amo

Oth

Description

HP255-14-01tem 2/22/200614 2ND FLOOR HEAD 0 0 012" GREEN FLOOR TILE

AND ADHESIVE

HP255-14-02 2/22/200614 2ND FLOOR HEAD 0 0 012" GREEN FLOOR TILE

AND ADHESIVE

HP255-15-01 2/22/200615 2ND FL ELECTRICAL 0 0 0MISCELLANEOUS

SEALANT

RED FIRESTOP

HP255-15-02 2/22/200615 2ND FL ELECTRICAL 0 0 0MISCELLANEOUS

SEALANT

RED FIRESTOP

HP255-16-01 2/22/200616 2ND FL LOUNGE 0 0 0CARPET ADHESIVE YELLOW

HP255-16-02 2/22/200616 2ND FL LOUNGE 0 0 0CARPET ADHESIVE YELLOW

HP255-17-01 2/22/200617 2ND FLOOR HALL 0 0 012" BROWN FLOOR TILE

AND MASTIC

HP255-17-01tem 2/22/200617 2ND FLOOR HALL 0.02 0 012" BROWN FLOOR TILE

AND MASTIC

HP255-17-02 2/22/200617 2ND FLOOR HALL 4 0 012" BROWN FLOOR TILE

AND MASTIC

HP255-18-00ri08 7/8/200918 N/A 9 9 9ROOFING MATERIAL, BLACK

HP255-18-00ri12 8/22/201218 N/A 9 9 9ROOFING MATERIAL, BLACK

HP255-18-00ri14 9/18/201418 N/A 9 9 9ROOFING MATERIAL, BLACK

HP255-18-01 2/22/200618 ATTIC/ ROOF CNTR 10 0 0ROOFING MATERIAL, BLACK

HP255-18-02 2/22/200618 ATTIC/ ROOF, NORTH CNTR 6 0 0ROOFING MATERIAL, BLACK

HP255-19-01 2/22/200619 3RD FL NORTH CHASE 0 0 0DUCT SEALANT, RED

HP255-19-02 2/22/200619 3RD FL NORTH CHASE 0 0 0DUCT SEALANT, RED

HP255-20-01 2/22/200620 3RD FL NORTH CHASE 0 0 0MASTIC ON HVAC DUCT

INSULATION,

GREEN

HP255-20-02 2/22/200620 3RD FL NORTH CHASE 0 0 0MASTIC ON HVAC DUCT

INSULATION,

GREEN

HP255-21-01 2/22/200621 3RD FL NORTH CHASE 0 0 0FIBERGLASS

INSULATION SEALANT

WHITE

HP255-21-02 2/22/200621 3RD FL NORTH CHASE 0 0 0FIBERGLASS

INSULATION SEALANT

WHITE

HP255-30-10 7/8/200930 1ST FL NORTH CHASE,

SOUTH END

0 0 0FOIL BACKED TAPE ON FIBERGLASS

Thursday, March 12, 2026 Page 9 of 11Print Date:

HA Sample Location Chr

Amo

Oth

Description

HP255-30-11 7/8/200930 3RD FL NORTH MR 0 0 0FOIL BACKED TAPE ON FIBERGLASS

HP255-31-10 7/8/200931 1ST FL NORTH CHASE,

SOUTH END

0 0 0CAPPING INSULATION

ON

FIBERGLASS

HP255-32-10 7/8/200932 1ST FL SOUTH CHASE,

NORTH END

0 0 0MISCELLANEOUS

SEALANT

BROWN

HP255-33-10 7/8/200933 1ST FL NORTH WING, EAST

CNTR RM DOOR

0 0 0INTERIOR CAULKING, WHITE

HP255-33-11 7/8/200933 1ST FL NORTH WING, EAST

CNTR RM SINK

0 0 0INTERIOR CAULKING, WHITE

HP255-33-12 7/8/200933 2ND FL SOUTH WING, EAST

CNTR RM DOOR

0 0 0INTERIOR CAULKING, WHITE

HP255-33-13 7/8/200933 3RD FL NORTH WING, EAST

CNTR RM DOOR

0 0 0INTERIOR CAULKING, WHITE

HP255-34-10 7/8/200934 1ST FL NORTH WING, EAST

CNTR DOOR

0 0 0EXTERIOR CAULKING, GRAY

HP255-34-11 7/8/200934 2ND FL SOUTH WING, EAST

CNTR DOOR

0 0 0EXTERIOR CAULKING, GRAY

HP255-34-12 7/8/200934 3RD FL NORTH WING, EAST

CNTR DOOR

0 0 0EXTERIOR CAULKING, GRAY

HP255-35-10 7/8/200935 3RD FL, EAST CNTR 0 0 0EXTERIOR CAULKING, WHITE

HP255-35-11 7/8/200935 3RD FL, WEST CNTR 0 0 0EXTERIOR CAULKING, WHITE

HP255-36-10 7/8/200936 3RD FL EAST CNTR 0 0 0EXTERIOR CAULKING, GRAY

HP255-36-11 7/8/200936 3RD FL WEST CNTR 0 0 0EXTERIOR CAULKING, GRAY

HP255-37-10 7/8/200937 3RD FL CNTR LAUNDRY 0 0 0WINDOW GLAZING

MATERIAL

BLACK

HP255-38-10 7/8/200938 SOUTH ROOF, CNTR 0 0 0BUILT-UP ROOFING TARS

HP255-38-11 7/8/200938 NORTH ROOF, CNTR 0 0 0BUILT-UP ROOFING TARS

HP255-389-10 7/8/200939 SOUTH ROOF CNTR 0 0 0ROOFING MATERIAL, DEBRIS

HP255-39-11 7/8/200939 NORTH ROOF CNTR 0 0 0ROOFING MATERIAL, DEBRIS

HP255-40-00ri12 8/22/201240 N/A 9 9 9ROOFING SEALANT, BLACK

HP255-40-00ri14 9/18/201440 N/A 9 9 9ROOFING SEALANT, BLACK

Thursday, March 12, 2026 Page 10 of 11Print Date:

HA Sample Location Chr

Amo

Oth

Description

HP255-40-10 7/8/200940 SOUTH ROOF CNTR WALL 10 0 0ROOFING SEALANT,

BLACK

HP255-40-11 7/8/200940 NORTH ROOF CNTR WALL 15 0 0ROOFING SEALANT,

BLACK

HP255-50-00ri18 2/8/201850 N/A 9 9 9MISCELLANEOUS

SEALANT

BLACK

HP255-50-00ri23 6/7/202350 N/A 9 9 9MISCELLANEOUS

SEALANT

BLACK

HP255-50-20 9/18/201450 1ST FL EAST CNTR, TWEEN

WALLS

7 0 0MISCELLANEOUS

SEALANT

BLACK

Thursday, March 12, 2026 Page 11 of 11Print Date:

File details come from the government source that posted it. Updated .