This is a Door Hardware Sets specification document for the D/B/B – Q-1075 SOF Building Additions project located at Dam Neck, Virginia (CN Comm. 8435). The specification details hardware requirements for fourteen distinct door types across exterior and interior applications within the facility.
The document prescribes comprehensive hardware sets for seven exterior door configurations (entrance doors, utility room doors, overhead coiling doors, and aluminum entrance system doors) and seven interior door configurations (controlled area entry, suite entry, office, conference room, wellness room, corridor/stair, restroom, storage/utility, and utility room doors). General requirements mandate that all stainless steel hardware be Type 316 material including fasteners and accessories; fire-rated and smoke-barrier doors must have hardware approved as part of labeled assemblies; sound attenuation sealing components must be part of manufacturer-tested assemblies with supporting documentation; and all operational components must be provided as part of the complete opening solution. Key hardware elements across sets include hinges (ranging from 1.5 to 3 pairs per door), mortise locksets with heavy-duty 316 stainless steel construction, closers, gasket weatherstripping, door bottoms, thresholds, electric strikes, card readers with PIN pads, and high security switches (HSS) meeting UL 634 standards. Card readers and HSS devices are specified as government-provided under separate contract. Thresholds are specified at 3 inches deep (minimum) by 1/2 inch high (maximum) for most applications, with specific variations for wellness rooms and restrooms. Sound control requirements range from STC 45 minimum for most doors to STC 50 minimum for conference and training rooms, with corresponding increases in weatherstripping sets for higher-rated applications.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D/B/B – Q-1075 SOF Bldg Additions Dam Neck, Va CN Comm. 8435
I:\Projects\8000\8435-Q1075 SOF Building Addition\Specs\Attachments\UPDATED 08 71 00 Door Hardware Sets_RAM 251202.docx
DOOR HARDWARE SETS
General Note(s):
- Refer to Door Schedule for identification of fire & smoke barrier ratings.
- All door hardware identified as stainless steel (SS) to be type 316, to include fasteners, clips, anchors, accessories, etc.
- All doors identified as fire resistant and / or smoke barrier rated to have hardware approved for said rating as part of labeled assembly.
- Sound attenuation sealing components to be part of the hardware manufacturers / suppliers tested assembly with associated supporting shop drawings and test reports.
- All components, accessories, trim, wiring or harnesses required to make the door assembly operational to be provided as part of the total opening solution, whether or not these parts are explicitly identified in these
Hardware Sets.
- Coordinate door hardware design intent with door details in drawing set.
Qty Description Finish ANSI/BHMA #
HDW-1 – Exterior Door – Entrance Door - STC 45 (min)
Door(s): 107B; 112B; 121B; 122D; 123B; 124B;124C
1.5 pr Hinge 4 1/2" x 4 1/2" (NRP) US32D A5111
1 ea Mortise Lockset – fail secure (un-secure side) US32D F04
1 ea Electric strike US32D -
1 ea Card reader w/ PIN pad (un-secure side) - -
1 ea High security switch (HSS) – recess mounted - -
1 ea Closer Alum C02011
1 set Gasket weatherstripping (head & jamb) – frame mounted Alum/Neo R3C253
1 set Gasket weatherstripping (head & jamb) – door mounted Silicone R0E117
1 ea Door Drip at door head Alum R3Y976
1 ea Door bottom w/ Rain Drip Alum/Neo R3C513
1 ea Threshold Alum J35229
Note(s):
- Lockset to be heavy duty (316) SS with lever handles.
I:\Projects\8000\8435-Q1075 SOF Building Addition\Specs\Attachments\UPDATED 08 71 00 Door Hardware Sets_RAM 251202.docx
- Card reader finish to be manufacturer’s standard, mount at strike side of door at 48” AFF.
- HSS to meet or exceed UL 634 Level 1 High Security Standard. This HSS to be integrated into existing security alarm system.
- Card reader(s) & HSS to be government provided under separate contract.
- Gasket weatherstripping, door bottom, and threshold assemblies to be delegated design as part of the door hardware manufacturer’s opening system solution.
- Threshold type to be 3” deep (min) x 1/2" high (max) x full width of door(s) between frame, panic latching exit saddle type with thermal break & neoprene seal.
HDW-2.0 – Exterior Door – Utility Room Door - STC 45 (min)
Door(s): 120, 125
3 pr Hinge 4 1/2" x 4 1/2" (NRP) US32D A5111
1 ea Mortise Lockset (active leaf) US32D F07
1 ea Dummy handle (in-active leaf) US32D -
1 ea Strike installed on in-active leaf for lockset latching US32D -
1 ea Closer (active leaf only) w/ hold open function Alum C02011
1 ea Astragal (T-type) Alum R3Y607
1 pr Flush bolts US32D L05081
1 ea Dustproof strike US32D L05021
2 ea High security switch (HSS) – recess mounted - -
1 ea Card reader w/ PIN pad (un-secure side) - -
1 set Gasket weatherstripping (head & jamb) – frame mounted Alum/Neo R3C253
1 set Gasket weatherstripping (head & jamb) – door mounted Silicone R0E117
1 ea Door Drip at door head Alum R3Y976
2 ea Door bottom w/ Rain Drip Alum/Neo R3C513
- Lockset to be heavy duty (316) SS with lever handles.
- HSS to meet or exceed UL 634 Level 1 High Security Standard. This HSS to be integrated into existing security alarm system.
- HSS to be government provided under separate contract.
- Threshold type to be 3” deep (min) x 1/2" high (max) x full width of door(s) between frame, panic latching exit
I:\Projects\8000\8435-Q1075 SOF Building Addition\Specs\Attachments\UPDATED 08 71 00 Door Hardware Sets_RAM 251202.docx
HDW-3 – Exterior Door – Overhead Coiling Door
Door(s): 104B; 112C; 123C; 124D; 124E
- Guide rails & brackets (including hardware) Galv Stl -
- Heavy duty rollers US32D -
2 ea Slide bolt lock (each end) US32D -
1 ea Push button operator - By Manuf
1 ea High security switch (HSS) – surface mounted - -
1 set Gasket weatherstripping (head & jamb seal) – frame mounted - By Manuf
1 ea Bottom seal (bulb type) Neoprene By Manuf
- The entire hardware package is the responsibility of the overhead door manufacturer, except for the HSS which will be coordinated with the government.
- HSS to meet or exceed UL 634 Level 2 High Security Standard. This HSS to be integrated into existing security alarm system.
- HSS to be government provided under separate contract.
- Hardware that is not prefinished to be (G90) galvanized steel or 316 stainless steel.
HDW-4 – Interior Door – Overhead Coiling Door
Door(s): 112D; 122B (Fire rated); 122C (Fire Rated)
- Guide rails & brackets (including hardware) Galv Stl -
- Heavy duty rollers US32D -
1 ea Push button operator - -
1 ea High security switch (HSS) – surface mounted - -
1 set Gasket weatherstripping (head & jamb seal) – frame mounted - By Manuf
1 ea Bottom seal (bulb type) Neoprene By Manuf
- The entire hardware package is the responsibility of the overhead door manufacturer, except for the HSS which will be coordinated with the government.
- HSS to meet or exceed UL 634 Level 1 High Security Standard. This HSS to be integrated into existing security alarm system.
- HSS to be government provided under separate contract.
- Hardware that is not prefinished to be (G90) galvanized steel or 316 stainless steel.
I:\Projects\8000\8435-Q1075 SOF Building Addition\Specs\Attachments\UPDATED 08 71 00 Door Hardware Sets_RAM 251202.docx
HDW-5 – Interior Door – Aluminum Entrance System Door (vestibule door)
Door(s): 101B
1 ea Continuous hinge US28 A31111G
2 ea Mortise Lockset w/ panic device – fail secure (un-secure side) US32D F04
1 ea Card reader w/ PIN pad (un-secure side) - -
2 ea Electric strike US32D -
2 ea High security switch (HSS) – surface mounted - -
2 ea Closer Alum C02021
1 set Gasket weatherstripping (head & jamb) - By Manuf
1 ea Door bottom w/ Rain Drip Alum/Neo R3C513
- Lockset to be heavy duty (316) stainless steel with exterior lever handle and interior panic device.
- HSS to meet or exceed UL 634 Level 1 High Security Standard.
- Card reader(s) & HSS to be government provided under separate contract.
- Balance of door hardware, not shown herein, to be responsibility of aluminum entrance manufacturer / supplier.
- Threshold type to be 3” deep (min) x 1/2" high (max) x full width of door(s) between frame, panic latching exit saddle type with thermal break & neoprene seal.
HDW-6 – Exterior Door – Aluminum Entrance System Door
Door(s):
2 ea Continuous hinge US28 A31111G
2 ea Mortise Lockset w/ panic device US32D F01
2 ea Closer Alum C02021
2 ea Threshold Alum J32131
- Lockset to be heavy duty (316) stainless steel with exterior lever handle and interior panic device.
- Balance of door hardware, not shown herein, to be responsibility of aluminum entrance manufacturer / supplier.
- Threshold type to be 3” deep (min) x 1/2" high (max) x full width of door(s) between frame, saddle type.
I:\Projects\8000\8435-Q1075 SOF Building Addition\Specs\Attachments\UPDATED 08 71 00 Door Hardware Sets_RAM 251202.docx
HDW-7 – Interior Door – Controlled Area Entry - STC 45 (min); Conference Room – STC 50 (min)
Door(s): 208; 218B; 222
1.5 pr Hinge 4 1/2" x 4 1/2" (NRP) US32D A5111
1 ea Mortise lockset w/ panic device – fail secure (un-secure side) US32D F04
1 ea Card reader w/ PIN pad (un-secure side) - -
1 ea Card reader w/o PIN pad (secure side) - -
1 ea Electric strike US32D -
1 ea High security switch (HSS) – surface mounted - -
1 ea Closer Alum C02011
1 set Gasket weatherstripping (head & jamb) – frame mounted Alum/Neo R3C253
1 set Gasket weatherstripping (head & jamb) – door mounted Silicone R0E117
2 sets Gasket weatherstripping (head & jamb) – door mounted – STC 50 doors ONLY Silicone R0E117
1 ea Door bottom (automatic) Alum/Neo R3C300
1 ea Threshold Alum J35229
Note(s):
- Lockset to be heavy duty with exterior lever handle and interior panic device and to be GSA approved pedestrian door lock meeting Federal Specification FF-L-2890B, Type III. Lockset to have integral electromechanical combination lock meeting Federal Specification FF-L-2740. Strike type to be surface mounted and coordinated with manufactures offerings.
- Omit panic device at in-swing doors, to be lever handles both sides – doors: 214A; 215A; 216A; 229A.
- Card reader(s) finish to be manufacturer’s standard, mount at strike side of door at 48” AFF.
- HSS to meet or exceed UL 634 Level 2 High Security Standard. This HSS to be integrated into existing security alarm system.
- Card reader(s) & HSS to be government provided under separate contract.
- Gasket weatherstripping, door bottom, and threshold assemblies to be delegated design as part of the door hardware manufacturer’s opening system solution.
- Threshold type to be 3” deep (min) x 1/2" high (max) x full width of door(s) between frame, panic latching exit saddle type with thermal break & neoprene seal.
HDW-7.1 – Interior Door – Controlled Area Egress Door (Exit Only) - STC 45 (min)
Door(s): 218A
1.5 pr Hinge 4 1/2" x 4 1/2" (NRP) US32D A5111
1 ea Mortise Lockset (exit only) w/ panic device US32D F31
1 ea Card reader w/o PIN pad (secure side) - -
1 ea High security switch (HSS) – surface mounted - -
1 ea Closer Alum C02011
I:\Projects\8000\8435-Q1075 SOF Building Addition\Specs\Attachments\UPDATED 08 71 00 Door Hardware Sets_RAM 251202.docx
1 set Gasket weatherstripping (head & jamb) – frame mounted Alum/Neo R3C253
1 set Gasket weatherstripping (head & jamb) – door mounted Silicone R0E117
1 ea Door bottom (automatic) Alum/Neo R3C300
- Lockset to be heavy duty with interior panic device with no exterior trim.
- Card reader(s) finish to be manufacturer’s standard, mount at strike side of door at 48” AFF.
- HSS to meet or exceed UL 634 Level 2 High Security Standard. This HSS to be integrated into existing security alarm system.
- Card reader(s) & HSS to be government provided under separate contract.
- Gasket weatherstripping, door bottom, and threshold assemblies to be delegated design as part of the door hardware manufacturer’s opening system solution.
- Threshold type to be 3” deep (min) x 1/2" high (max) x full width of door(s) between frame, panic latching exit saddle type with thermal break & neoprene seal.
HDW-8 – Interior Door – Suite Entry Door - STC 45 (min)
Door(s): 102; 103, 104A; 105; 107A; 111; 112A; 114A; 114B; 121A; 123A; 124A; 201; 206A; 207A; 207B; 228
1.5 pr Hinge 4 1/2" x 4 1/2" (NRP for reverse swing doors) US32D A5111
1 ea Mortise Lockset – fail secure (un-secure side) US32D F04
1 ea Card reader w/ PIN pad (un-secure side) - -
1 ea High security switch (HSS) – surface mounted - -
1 ea Closer Alum C02011
1 set Gasket weatherstripping (head & jamb) – frame mounted Alum/Neo R3C253
1 set Gasket weatherstripping (head & jamb) – door mounted Silicone R0E117
1 ea Door bottom (automatic) Alum/Neo R3C300
- Lockset to be heavy duty with lever handles.
- Card reader(s) finish to be manufacturer’s standard, mount at strike side of door at 48” AFF.
- HSS to meet or exceed UL 634 Level 1 High Security Standard. This HSS to be integrated into existing security alarm system.
- Card reader(s) & HSS to be government provided under separate contract.
- Gasket weatherstripping, door bottom, and threshold assemblies to be delegated design as part of the door hardware manufacturer’s opening system solution.
- Threshold type to be 3” deep (min) x 1/2" high (max) x full width of door(s) between frame, panic latching exit
I:\Projects\8000\8435-Q1075 SOF Building Addition\Specs\Attachments\UPDATED 08 71 00 Door Hardware Sets_RAM 251202.docx
HDW-9 – Interior Door – Office Door - STC 45 (min)
Door(s): 202; 203; 209; 210A; 211; 219; 220; 221; 230; 231; 232; 233
1.5 pr Hinge 4 1/2" x 4 1/2" US32D A5111
1 ea Mortise Lockset – fail secure (un-secure side) US32D F04
1 ea Card reader w/ PIN pad (un-secure side) - -
1 ea High security switch (HSS) – surface mounted - -
1 set Gasket weatherstripping (head & jamb) – frame mounted Alum/Neo R3C253
1 set Gasket weatherstripping (head & jamb) – door mounted Silicone R0E117
1 ea Door bottom (automatic) Alum/Neo R3C300
1 ea Threshold Alum J35229
Note(s):
- Lockset to be heavy duty with lever handles.
- Card reader(s) finish to be manufacturer’s standard, mount at strike side of door at 48” AFF.
- Doors 202; 203; 230; 231; 232; and 233: HSS to meet or exceed UL 634 Level 1 High Security Standard. This
HSS to be integrated into existing security alarm system.
- Doors 209; 210A; 211; 219; 220; and 221: HSS to meet or exceed UL 634 Level 2 High Security Standard. This
HSS to be integrated into existing security alarm system.
- Card reader(s) & HSS to be government provided under separate contract.
- Gasket weatherstripping, door bottom, and threshold assemblies to be delegated design as part of the door hardware manufacturer’s opening system solution.
- Threshold type to be 3” deep (min) x 1/2" high (max) x full width of door(s) between frame, panic latching exit saddle type with thermal break & neoprene seal.
HDW-9.1 – Interior Door – Conference Room & Training Room Door - STC 50 (min)
Door(s): 224; 229*
1.5 pr Hinge 4 1/2" x 4 1/2" US32D A5111
1 ea Lockset – fail secure (un-secure side) US32D F04
1 ea Card reader w/ PIN pad (un-secure side) - -
1 ea High security switch (HSS) – surface mounted - -
1 set Gasket weatherstripping (head & jamb) – frame mounted Alum/Neo R3C253
2 set Gasket weatherstripping (head & jamb) – door mounted Silicone R0E117
1 ea Door bottom (automatic) Alum/Neo R3C300
1 ea Threshold Alum J35229
Note(s):
- Card reader(s) finish to be manufacturer’s standard, mount at strike side of door at 48” AFF.
I:\Projects\8000\8435-Q1075 SOF Building Addition\Specs\Attachments\UPDATED 08 71 00 Door Hardware Sets_RAM 251202.docx
- HSS to meet or exceed UL 634 Level 2 High Security Standard. This HSS to be integrated into existing security alarm system.
- Card reader(s) & HSS to be government provided under separate contract.
- Gasket weatherstripping, door bottom, and threshold assemblies to be delegated design as part of the door hardware manufacturer’s opening system solution.
- Threshold type to be 3” deep (min) x 1/2" high (max) x full width of door(s) between frame, panic latching exit saddle type with thermal break & neoprene seal.
- *Door 229 HSS to meet or exceed UL634 Level 1 High Security standard.
HDW-10 – Interior Door –Wellness Room Door
Door(s): 106
1.5 pr Hinge 4 1/2" x 4 1/2" US32D A5111
1 ea Lockset US32D F02
1 ea Closer Alum C02011
1 ea Occupancy indicator - -
3 ea Silencer (frame mounted on strike side) Rubber -L03011
1 ea Mop plate US32D J103
1 ea Kick plate US32D J102
1 ea Resilient transition – doors 119A ONLY - See drawings
Note(s):
- Lockset to be heavy duty with lever handles.
- Occupancy indicator may be standalone piece of hardware or integrated into door lockset, must identify
“VACANT” in green or “OCCUPIED” in red.
- At PRC flooring: Threshold type to be 2” deep x 1/2" high (max) x full width of door(s) between frame, marble
‘flat bar’ type. Marble threshold to be provided & installed by flooring supplier / installer.
- At RFT flooring: Threshold type to be 3” deep x 1/2" high (max) x full width of door(s) between frame, saddle type.
HDW-11 – Interior Door – Corridor / Stair without Card Reader
Door(s): 212
1.5 pr Hinge 4 1/2" x 4 1/2" US32D A5111
1 ea Mortise Lockset (non-locking) w/ panic device US32D F01
1 ea Closer Alum C02011
3 ea Silencer (frame mounted on strike side) Rubber L03011
1 ea Threshold Alum J32191
- Lockset to be heavy duty with exterior lever handle and interior panic device.
I:\Projects\8000\8435-Q1075 SOF Building Addition\Specs\Attachments\UPDATED 08 71 00 Door Hardware Sets_RAM 251202.docx
- Threshold type to be 3” deep x 1/2" high (max) x full width of door(s) between frame, saddle type.
HDW-11.1 – Interior Door – Corridor / Stair with Card Reader
Door(s): 109; 122A; 227
1.5 pr Hinge 4 1/2" x 4 1/2" US32D A5111
1 ea Mortise Lockset (non-locking) w/ panic device US32D F01
1 ea Closer Alum C02011
3 ea Silencer (frame mounted on strike side) Rubber L03011
1 ea Card reader w/ PIN pad (un-secure side) - -
1 ea High security switch (HSS) – surface mounted - -
- Lockset to be heavy duty with lever handles.
- Card reader finish to be manufacturer’s standard, mount at strike side of door at 48” AFF.
- HSS to meet or exceed UL 634 Level 1 High Security Standard. This HSS to be integrated into existing security alarm system.
- Card reader(s) & HSS to be government provided under separate contract.
- Threshold type to be 3” deep x 1/2" high (max) x full width of door(s) between frame, saddle type.
- *Doors 206B and 223 do not need a threshold, mop plate, or kickplate
HDW-12 – Interior Door – Restroom Door
Door(s): 117A; 117B; 216; 217
1.5 pr Hinge 4 1/2" x 4 1/2" US32D A5111
1 ea Door pull w/ backplate US32D J401 / J407
1 ea Door push plate US32D J304
1 ea Closer Alum C02011
2 set Gasket weatherstripping (head & jamb) – door mounted Silicone R0E117
1 ea Mop plate US32D J103
1 ea Kick plate US32D J102
1 ea Threshold (by floor finish supplier) Marble -
- Threshold type to be 2” deep x 1/2" high (max) x full width of door(s) between frame, marble ‘flat bar’ type.
Marble threshold to be provided & installed by flooring supplier / installer.
I:\Projects\8000\8435-Q1075 SOF Building Addition\Specs\Attachments\UPDATED 08 71 00 Door Hardware Sets_RAM 251202.docx
HDW-13 – Interior Door – Storage / Utility with Card Reader
Door(s): 113; 115; 116; 205; 206B*, 215, 223*; 226
1.5 pr Hinge 4 1/2" x 4 1/2" US32D A5111
1 ea Mortise Lockset US32D F07
3 ea Silencer (frame mounted on strike side) Rubber -L03011
1 ea Mop plate US32D J103
1 ea Kick plate US32D J102
1 ea Threshold Alum J32191
1 ea Card reader with PIN pad - -
1 ea Electric strike US32D -
1 ea High security switch (HSS) – surface mounted - -
Note(s):
- Lockset to be heavy duty with lever handles.
- Threshold type to be 3” deep x 1/2" high (max) x full width of door(s) between frame, saddle type.
- Card reader finish to be manufacturer’s standard, mount at strike side of door at 48” AFF.
- HSS to meet or exceed UL 634 Level 1 High Security Standard. This HSS to be integrated into existing security alarm system.
- Card reader(s) & HSS to be government provided under separate contract.
- Threshold type to be 3” deep x 1/2" high (max) x full width of door(s) between frame, saddle type.
- *Doors 206B and 223 do not need a threshold, mop plate, or kickplate
HDW-14 – Interior Door – Utility Room Door
Door(s): 108
3 pr Hinge 4 1/2" x 4 1/2" (NRP) US32D A5111
1 ea Mortise Lockset (active leaf) US32D F07
1 ea Dummy handle (in-active leaf) US32D -
1 ea Strike installed on in-active leaf for lockset latching US32D -
1 ea Astragal (T-type) Alum R3Y607
1 pr Flush bolts US32D L05081
1 ea Mop plate US32D J103
1 ea Kick plate US32D J102
1 ea Dustproof strike US32D L05021
1 ea Card reader w/ PIN pad (un-secure side) - -
1 ea High security switch (HSS) – surface mounted - -
I:\Projects\8000\8435-Q1075 SOF Building Addition\Specs\Attachments\UPDATED 08 71 00 Door Hardware Sets_RAM 251202.docx