C-501 CIVIL DETAILS_Amended.pdf

PDF 361 KB Posted

Attached to
LP-40 Install In-Line Receipt Filtration, Naval Station Norfolk, Norfolk, Virginia
Solicitation number
N4008525R2655
Issued by

About this file

This document is a technical drawing (C-501) detailing civil engineering specifications for a Naval Facilities Engineering Systems Command (NAVFAC) project at Norfolk Naval Station. The drawing provides detailed schematics for a 600 GPM vertical filter/separator system, including a material list and technical specifications for key components such as a vertical separator, auto air eliminator, lifting arm assembly, pressure relief valve, differential pressure gauge, sight glass, and various valves and connections.

The technical drawing specifies precise details for drain and vent piping, including a 6-inch discharge flow control valve and a 6-inch fuel meter. The system is designed for installation within an existing concrete slab with a curb containment at the LP Fuel Farm. Components are specified with precise measurements and technical requirements, such as stainless steel vent piping and specific flange and valve specifications. The drawing is dated 10/30/24 and was prepared by J. Miller, P.E., with the project number 1694038, indicating a structured approach to the naval facility's fuel filtration infrastructure upgrade.

View the file

Other files

Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FI

LE

N

AM

E:

P:

\V A\

Na va lS tat ion No rfo lk\

Si tew or k\S ite Ut ilit ies

\F ue l\2

1_

8_

LP

-4 0_

In- Lin e R ec eip t F iltr ati on \B

_D es ign \D

W

GS

\S he et\

_C

IV

\C -5

C

IV

IL

DE

TA

ILS

_A me nd ed .dw g P

LO

TT

ED

: Fr ida y, Ap ril

4, 1:

:57

P M U

SE

R:

jer em y.b

.jo ne s1

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

S

YS

TE

M

S C

O M

M

AN

D

DES DRW

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

DRAWFORM REVISION: 14 SEP 2023

CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D~

M

ID

LA

NT

PW

D

N O

R

FO

LK

N

AV

AL

S

TA

TI

O

N N

O R

FO

LK

N

AV

AL

S

TA

TI

O N

N O

R

FO

LK

N

O R

FO

LK

, V A

LP

-4

IN

L

IN

E R

E C

E

IP

T

FI

LT

R

A

TI

O N

10/30/24

JBJ

J. MILLER, P.E.

NA

1694038

NA

W. BOUNDS, FLC

C

IV

IL

D

E

TA

IL

S

JBJ JBJ WHW

AS NOTED

12913661

C-501

WHW

600 GPM VERTICAL SEPARATOR

15 15

DRAIN & VENT PIPING SCHEMATICS FOR SEPARATORS

600 GPM VERTICAL VERTICAL SEPARATOR

6-INCH DISCHARGE FLOW CONTROL VALVE

6-INCH FUEL METER

AMENDED

DETAIL

AutoCAD SHX Text

EXISTING CONCRETE SURFACE

AutoCAD SHX Text

AIR VENT

AutoCAD SHX Text

PRESSURE RELIEF VALVE

AutoCAD SHX Text

BALL VALVE

AutoCAD SHX Text

UNION

AutoCAD SHX Text

1.0 INCH PRESSURE RELIEF LINE FROM FILTER

AutoCAD SHX Text

1.0 INCH AIR RELIEF LINE FROM FILTER

AutoCAD SHX Text

1-INCH DRAIN LINE TO AST

AutoCAD SHX Text

0.75-INCH DRAIN LINE TO ATMOSPHERE

AutoCAD SHX Text

FLOW DIRECTION

AutoCAD SHX Text

1-INCH DISCHARGE

AutoCAD SHX Text

FLANGE ACCESS

AutoCAD SHX Text

REDUCER

AutoCAD SHX Text

600 GPM VERTICAL FILTER/SEPARATOR

AutoCAD SHX Text

VENT PIPING

AutoCAD SHX Text

CONTROL TUBING TO VALVE

AutoCAD SHX Text

VENT PIPING TO BE STAINLESS STEEL. REFER TO SPECIFICATIONS.

AutoCAD SHX Text

TYPICAL OF (3)

AutoCAD SHX Text

TYPICAL OF (3)

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

1. MANUFACTURER'S TRADE NAMES LISTED ARE NOT INTENDED TO BE PROPRIETARY. MANUFACTURER'S TRADE NAMES LISTED ARE NOT INTENDED TO BE PROPRIETARY. PRODUCTS OF OTHER MANUFACTURERS WILL BE ACCEPTABLE PROVIDED THEY MATCH THE COLOR, FINISHES, TEXTURES AND PATTERNS OF THE MANUFACTURER LISTED, AND MEET THE TECHNICAL REQUIREMENTS OF THE SPECIFICATIONS. 2. SEPARATOR MUST MEET THE REQUIREMENTS OF FACET MODEL VCS-643-236, 600 GPM SEPARATOR MUST MEET THE REQUIREMENTS OF FACET MODEL VCS-643-236, 600 GPM VERTICAL FILTER SEPARATOR AS DESIGNED IN ACCORDANCE WITH EI (ENERGY INSTITUTE) 1581 6TH EDITION, CATEGORY M, TYPE S. FLOW RATE; 600 GPM FUEL SERVICE: JET FUELS, JP-4, JP-5, JP-8: F24 MATERIAL OF CONSTRUCTION: CARBON STEEL INLET CONNECTION: 6-INCH 150# ANSI RAISED FACE OUTLET CONNECTION: 6-INCH 150# ANSI RAISED FACE UNIT WORKING PRESSURE: 275 PSI ASME CODE LABELED PER ASME SECTION VIII DIVISION1 INTERNAL COATING: EPOXY PER MIL-PRF-4556 EXTERNAL COATING: UNIVERSAL METAL PRIMER COALESCER ELEMENTS: (6) EACH SEPARATOR ELEMENTS: (2) EACH

AutoCAD SHX Text

MATERIAL LIST FOR VERTICAL SEPARATOR

AutoCAD SHX Text

AutoCAD SHX Text

600 GPM VERTICAL FILTER/SEPARATOR, FACET MODEL VCS-643-236 OR EQUAL

AutoCAD SHX Text

AutoCAD SHX Text

AUTO AIR ELIMINATOR WITH 0.75-INCH NPT CHECK VALVE

AutoCAD SHX Text

AutoCAD SHX Text

LIFTING ARM ASSEMBLY FOR TOP COVER (NOT SHOWN COMPLETELY)

AutoCAD SHX Text

AutoCAD SHX Text

MANUAL AIR VENT, 0.75-INCH NPT

AutoCAD SHX Text

AutoCAD SHX Text

PRESSURE RELIEF VALVE, 1-INCH 150 # FLANGE

AutoCAD SHX Text

AutoCAD SHX Text

LIFT LUGS, 3-INCH DIA. HOLE, (TYP. 2)

AutoCAD SHX Text

AutoCAD SHX Text DIFFERENTIAL PRESSURE GAUGE, 0.25-INCH NPT SS DIRECT READING PISTON TYPE 0-30 PSI RANGE, COMPLETE WITH PEAK HOLD AND PUSH BUTTON TEST VALVE FEATURE AND 300 PSI SYSTEM PRESSURE GAUGE, 0.25-INCH SS BAR STOCK VALVES

AutoCAD SHX Text

AutoCAD SHX Text

SIGHT GLASS

AutoCAD SHX Text

AutoCAD SHX Text

6-INCH INLET, 6-INCH 150# FLANGE

AutoCAD SHX Text

AutoCAD SHX Text

6-INCH OUTLET, 6-INCH 150# FLANGE

AutoCAD SHX Text

AutoCAD SHX Text

INLET CHAMBER DRAIN, 0.75-INCH NPT

AutoCAD SHX Text

AutoCAD SHX Text

OUTLET CHAMBER DRAIN, 0.75-INCH NPT

AutoCAD SHX Text

AutoCAD SHX Text

PILOT CONTROL VALVE, FLANGED FLOAT CONTROL CLA-VAL MODEL CFF21 OR EQUAL

AutoCAD SHX Text

AutoCAD SHX Text

MANUAL WATER DRAIN, 1-INCH 150# FLANGE W/BALL VALVE

AutoCAD SHX Text

AutoCAD SHX Text

SAMPLE KIT CONNECTIONS

AutoCAD SHX Text

1. MANUFACTURER'S TRADE NAMES LISTED ARE NOT INTENDED TO BE PROPRIETARY. PRODUCTS MANUFACTURER'S TRADE NAMES LISTED ARE NOT INTENDED TO BE PROPRIETARY. PRODUCTS OF OTHER MANUFACTURERS WILL BE ACCEPTABLE PROVIDED THEY MATCH THE COLOR, FINISHES, TEXTURES AND PATTERNS OF THE MANUFACTURER LISTED, AND MEET THE TECHNICAL REQUIREMENTS OF THE SPECIFICATIONS. 2. VALVE OPERATIONAL DESIGN IS BASED UPON CLA-VAL MODEL #40-38 ACGS WHICH VALVE OPERATIONAL DESIGN IS BASED UPON CLA-VAL MODEL #40-38 ACGS WHICH ACCOMPLISHES TWO FUNCTIONS: A COMBINATION RATE OF FLOW CONTROLLER AND FUEL SHUTOFF VALVE. THE FLOAT CONTROL INSIDE THE VERTICAL SEPARATOR HAS A SENSING LINE CONNECTED BY A THREE WAY VALVE AS PART OF THE CONTROL VALVE ASSEMBLY. IF WATER IS PRESENT INSIDE THE VERTICAL SEPARATOR, THE SENSING LINE WILL APPLY PRESSURE TO THE COVER OF THE MAIN VALVE AND CAUSE THE VALVE TO CLOSE. THIS PREVENTS A "WATER SLUG" (I.E. WATER IS PRESENT) FROM ENTERING THE DOWNSTREAM TANKS. THE DOWNSTREAM ORIFICE PLATE (ON THE CONTROL VALVE) IS UTILIZED IN CONJUNCTION WITH A PRESSURE DIFFERENTIAL CONTROL TO ADJUST THE RATE OF FLOW (BY OPENING AND CLOSING THE CONTROL VALVE).

AutoCAD SHX Text

1. METER MUST BE ONE-WAY FLOW, TEMPERATURE COMPENSATING, POSITIVE DISPLACEMENT METER DESIGNED FOR A CONTINUOUS FLOW OF 1000 GPM. METER MUST BE ONE-WAY FLOW, TEMPERATURE COMPENSATING, POSITIVE DISPLACEMENT METER DESIGNED FOR A CONTINUOUS FLOW OF 1000 GPM. 2. METER MUST BE FACTORY CALIBRATED FOR JP-5 AND CAPABLE OF FIELD CALIBRATION. ACCURACY MUST BE WITHIN 0.3 PERCENT FOR FLOW RANGES METER MUST BE FACTORY CALIBRATED FOR JP-5 AND CAPABLE OF FIELD CALIBRATION. ACCURACY MUST BE WITHIN 0.3 PERCENT FOR FLOW RANGES BETWEEN 100 TO 1000 GPM. 3. REGISTER MUST HAVE (8) FIGURES MINIMUM WITH THE SMALLEST UNIT BEING (1) GALLON. REGISTER MUST HAVE (8) FIGURES MINIMUM WITH THE SMALLEST UNIT BEING (1) GALLON. 4. METER MUST HAVE A SUITABLE DRAIN AT BOTTOM EQUIPPED WITH A BALL VALVE.METER MUST HAVE A SUITABLE DRAIN AT BOTTOM EQUIPPED WITH A BALL VALVE.

Sheets and Views
C-501

File details come from the government source that posted it. Updated .