These documents are specifications for the Cole's Bistro Renovation project (eProjects Work Order Number 1834937, Construction Contract Number N40085-25-R-0100 NSN) for Building W-143, issued by PWD Norfolk, Facilities Engineering and Acquisition Division. The specifications cover two key sections: Aluminum-Framed Entrances and Storefronts (Section 08 41 13) and Glazing (Section 08 81 00).
The Aluminum-Framed Entrances and Storefronts specification details requirements for installing medium stile aluminum entrance systems with specific material standards, including ASTM B221 6063-T5 alloy, precise dimensional tolerances, and finish specifications. The document mandates a clear anodized finish, comprehensive submittal requirements, and a five-year warranty. The Glazing specification outlines requirements for glass types (including clear and tempered glass), setting and sealing materials, and installation procedures, with specific attention to material quality, environmental conditions, and protective measures during installation. Both sections provide detailed technical guidance for the renovation project, covering everything from material selection to installation methods and quality control.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PWD Norfolk, Facilities Engineering and Acquisition Division Form Version 2023.11.07 Page 1 of 2
Design Revision 01 eProjects Work Order Number: 1834937
Construction Contract Number: N40085-25-R-0100 NSN
Buildings: W-143
Project Title: Cole’s Bistro Renovation
Date: 6 August 2025
Design Revision Purpose
1. Response to PPIs
Specification Revisions
The following specifications, dated 8/6/2025, are added to accompany this Design Revision:
DIVISION 08 – OPENINGS
08 81 00 – GLAZING
The following specifications, dated 8/6/2025, are revised to accompany this Design Revision:
DIVISION 08 – OPENINGS
08 41 13 – ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS
Noted Revisions
Drawings:
Noted Revisions are not included in sheets & specification sections that have been added or re-issued.
Please make the following modifications to the drawing set:
On NAVFAC Drawing No. - 12,928,009 (AE409) Keynote 3: Revise note to read: “INSTALL NEW CERAMIC TILE ON EXISTING WALLS. REFER TO
PARTITION TYPES AND FINISH SCHEDULE. (QTY: +/- 272 SF CERAMIC TILE)”
On NAVFAC Drawing No. - 12,928,029 (AF601) Finish Schedule: Revise ceiling finish at rooms 616, 618, 623 & 625 to read “OPEN TO ABOVE”.
On NAVFAC Drawing No. - 12,928,099 (EP401) Keynote 2: Revise not to read: “PROVIDE TWO 4” RGS CONDUITS, EACH CONTAINING FOUR #500 KCIL, ONE #2 GROUND FROM 600 AMP, 3 POLE CIRCUIT BREAKER PANEL HA. SEE DETAIL B1 AND C1 FOR
ROUTING.”
PWD Norfolk, Facilities Engineering and Acquisition Division Form Version 2023.11.07 Page 2 of 2
On NAVFAC Drawing No. - 12,928,100 (EP402) Keynote 8: Revise not to read: “PROVIDE A 480/277V, 125A MLO PANELBOARD. SEE PANEL SCHEDULE
ON SHEET EP701.”
Coles Bistro 1834937
SECTION 08 41 13
ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS
08/18, CHG 1: 08/18
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ALUMINUM ASSOCIATION (AA)
AA DAF45 (2003; Reaffirmed 2009) Designation System for Aluminum Finishes
AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)
AAMA 501 (2015) Methods of Test for Exterior Walls
AAMA 800 (2016) Voluntary Specifications and Test Methods for Sealants
AAMA 1503 (2009) Voluntary Test Method for Thermal Transmittance and Condensation Resistance of Windows, Doors and Glazed Wall Sections
AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE)
ASCE 7-16 (2017; Errata 2018; Supp 1 2018) Minimum Design Loads and Associated Criteria for Buildings and Other Structures
ASTM INTERNATIONAL (ASTM)
ASTM B221 (2021) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes
ASTM E331 (2000; R 2023) Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference
ASTM F1642/F1642M (2017) Standard Test Method for Glazing and Glazing Systems Subject to Airblast Loadings
BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)
ANSI/BHMA A156.4 (2024) Door Controls - Closers
INTERNATIONAL CODE COUNCIL (ICC)
ICC IBC (2024) International Building Code
SECTION 08 41 13 Page 1
U.S. GENERAL SERVICES ADMINISTRATION (GSA)
FS TT-P-645 (Rev C; Notice 1) Primer, Paint, Zinc-Molybdate, Alkyd Type
UNDERWRITERS LABORATORIES (UL)
UL 325 (2017; Reprint Feb 2020) UL Standard for Safety Door, Drapery, Gate, Louver, and Window Operators and Systems
1.2 ADMINISTRATIVE REQUIREMENTS
1.2.1 Pre-Installation Meetings
Conduct a meeting before installation begins to verify the project requirements, substrate conditions, manufacturer's installation instructions, and manufacturer's warranty requirements.
Within 30 days of the Contract Award, submit the following for review and approval by the Contracting Officer:
a. List of product installations
b. Sample warranty
c. Finish and color samples
d. Manufacturer's catalog data
Concurrently submit certified test reports showing compliance with specified performance characteristics and UL 325 for the following:
a. Wind Load (Resistance) in accordance with AAMA 501
b. Deflection in accordance with ASTM F1642/F1642M
c. Condensation Resistance and Thermal Transmittance Performance Requirements in accordance with AAMA 1503
d. Water Infiltration in accordance with ASTM E331
e. Structural Requirements in accordance with ASTM F1642/F1642M
1.3 SUBMITTALS
Government approval is required for submittals with a "G" or "S" classification. Submittals not having a "G" or "S" classification are for Contractor Quality Control approval. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-01 Preconstruction Submittals
Sample Warranty; G
List of Product Installations; G
SD-02 Shop Drawings
SECTION 08 41 13 Page 2
Installation Drawings; G
Fabrication Drawings; G
SD-03 Product Data
Manufacturer's Catalog Data; G
Finish; G
SD-04 Samples
Finish and Color Samples; G
SD-08 Manufacturer's Instructions
Manufacturer's Instructions
SD-11 Closeout Submittals
Manufacturer's Product Warranty
1.4 QUALITY CONTROL
1.4.1 Qualifications
1.4.1.1 Installer Qualifications
Provide documentation of the installer's experience as determined by the Contractor in performing the work specified in this section.
Ensure that the installers are specialized in work similar to that required for this project, and that they are acceptable to product manufacturer.
1.4.1.2 Manufacturer Qualifications
Ensure that manufacturers meet the requirements specified in this section and project drawings.
Ensure that the manufacturer is capable of providing field service representation during construction, approving acceptable installers and approving application methods.
1.4.2 Single-Source Responsibility
When aluminum entrances are part of a building enclosure system, that includes storefront framing, windows, a curtain wall system, and related products, provide building enclosure system products from a single-source manufacturer.
Use a single source manufacturer with sole responsibility for providing design, structural engineering, and custom fabrication for door portal systems and for supplying components, materials, and products. Do not use products provided from numerous sources for assembly at the site. Ensure that the following work items and components are fabricated or supplied by a single source are:
a. Door assemblies to be installed in door portals as specified in
SECTION 08 41 13 Page 3 drawings .
b. Glazed walls to be constructed around door portals as specified in this Section.
c. Door operating hardware to be installed on or within door portals as specified in Section 08 71 00 DOOR HARDWARE.
d. Glass as specified in Section 08 81 00 GLAZING.
1.5 DELIVERY, STORAGE, AND HANDLING
1.5.1 Ordering
To avoid construction delays, comply with the manufacturer's lead-time requirements and instructions for ordering.
1.5.2 Packing, Shipping, Handling and Unloading
Deliver materials in the manufacturer's original, unopened, undamaged containers with identification labels intact.
1.5.3 Storage and Protection
Store materials in a way that protects them from exposure to harmful weather conditions. Avoid damaging the storefront material and components during handling. Protect storefront material against damage from elements, construction activities, and other hazards before, during, and after storefront installation.
Do not use adhesive papers or sprayed coatings that become firmly bonded when exposed to sunlight. Do not leave coating residue on surfaces.
1.6 PROJECT / SITE CONDITIONS
1.6.1 Field Measurements
Verify actual measurements or openings by taking field measurements before fabrication; record these measurements on shop drawings. To avoid construction delays, coordinate field measurements, and fabrication schedule with construction progress.
1.7 WARRANTY
Provide a written manufacturer's warranty, executed by a company official, warranting against defects in materials and products for 2 years from the date of shipment. Warrant that the door corner construction is for the life of the project.
PART 2 PRODUCTS
2.1 SYSTEM DESCRIPTION
Provide aluminum entrances, with glass and glazing, door hardware, and components.
Aluminum entrances include impact resistance entrances; medium stile, 3
SECTION 08 41 13 Page 4
1/2 inch vertical face dimension, 1-3/4 inch depth, for interior structural silicone glaze, for high-traffic/impact-resistant applications.
2.1.1 Design Requirements for Aluminum (Entrances and Components)
Provide a door portal system designed to withstand the following loads without breakage, loss, failure of seals, product deterioration, or other defects.
a. Dead and Live Loads: Determined by ASCE 7-16 and calculated in accordance with applicable codes.
b. Seismic Loads: Design and install the system to comply with the seismic requirements for the project location in accordance with Section 1613 of the International Building Code, ICC IBC .
2.1.1.1 Material Standard
ASTM B221; 6063-T5 alloy and tempered.
Provide door stile and rail face dimensions of the entrance doors as follows:
Vertical Stile Top Rail Bottom Rail
3-1/2 inches 3-1/2 inches 6-1/2 inches
Provide major portions of the door members at 0.125 inches nominal in thickness and glazing molding at 0.050 inches thick.
2.1.1.2 Sealants
Provide either ethylene propylene diene monomer (EPDM) elastomeric extrusions or thermoplastic elastomer glazing gaskets. Structural silicone sealant is required.
Internal Sealants: Provide sealants that according to the manufacturer will remain permanently elastic, tacky, non-drying, non-migrating, and weather tight.
2.2 FABRICATION
Provide the following information when submitting fabrication drawings for custom fabrications:
a. Indicate elevations, detailed design, dimensions, member profiles, joint locations, arrangement of units, and member connections.
b. Show the following items:
(1) Details of special shapes.
(2) Reinforcing.
(3) Anchorage system.
(4) Interfacing with building construction.
SECTION 08 41 13 Page 5
(5) Provisions for expansion and contraction.
c. Indicate typical glazing details, locations of various types and thickness of glass, and internal sealant requirements as recommended by the sealant manufacturer.
d. Clearly indicate locations of exposed fasteners and joints.
e. Clearly show where and how the manufacturer's system deviates from Contract drawings and these specifications.
2.2.1 Entrance System Fabrication
Provide door corner construction consisting of mechanical clip fastening, SIGMA deep penetration plug welds and 1-1/8 inch long fillet welds inside and outside all four corners. Provide a hook-in type exterior glazing stop with EPDM glazing gaskets reinforced with non-stretchable cord.
Provide an interior glazing stop that is mechanically fastened to the door member and that incorporates a silicone-compatible spacer used with silicone sealant.
Accurately fit and secure joints and corners. Make joints hairline in appearance. Remove burrs and smooth edges. Prepare components with internal reinforcement for door hardware. Arrange fasteners and attachments so that they are concealed from view.
Separate dissimilar metals with protective coating or pre-formed separators to prevent contact and corrosion.
2.2.2 Shop Assembly
Fabricate and assemble units with joints only at the intersection of aluminum members with hairline joints; rigidly secure these units, and seal them in accordance with the manufacturer's recommendations.
2.2.2.1 Welding
Conceal welds on aluminum members in accordance with AWS recommendations or methods recommended by the manufacturer. Members showing welding bloom or discoloration on finish or material distortion will be rejected by the Contacting Officer.
2.2.3 Finish
Before fabrication, clean the units and give them a AA-M-10-C22-A31 clear (natural) anodized finish in accordance with the requirements of the AA DAF45. The finish thickness is A42, 0.7 mil or greater.
Select and edit the following items for appropriate finish; delete types that do not apply.
(1) Architectural Class I
(2) Etched, medium matte
Clear anodic coating, 0.7 mil minimum thickness
SECTION 08 41 13 Page 6
2.2.4 Fabrication Tolerance
Fabricate and assemble units with joints only at intersection of aluminum members with hairline joints; rigidly secure these units, and seal them in accordance with the manufacturer's recommendations.
Fabricate aluminum entrances in accordance with the entrance manufacturer's prescribed tolerances.
2.2.4.1 Material Cuts
Square to 1/32 inch off square, over largest dimension; proportionate amount of 1/32 inch on the two dimensions.
2.2.4.2 Maximum Offset at Consecutive Members
1/64 inch in alignment between two consecutive members in line, end to end.
2.2.4.3 Maximum Offset at Glazing Pocket Corners
1/64 inch between framing members at glazing pocket corners.
2.2.4.4 Joints
Between adjacent members in same assembly: Joints are hairline and square to the adjacent member.
2.2.4.5 Variation
In squaring diagonals for doors and fabricated assemblies: 1/16 inch.
2.2.4.6 Flatness
For doors and fabricated assemblies: plus/minus 1/16 inch of neutral plane.
2.3 MATERIALS
2.3.1 Sealants
Refer to Section 07 92 00 JOINT SEALANTS. Ensure that all sealants conform to AAMA 800.
2.4 ACCESSORIES
2.4.1 Fasteners
Provide stainless steel fasteners in areas where the fasteners are exposed.
Use non-corrosive and compatible fasteners with components being fastened. Do not use exposed fasteners, except where unavoidable for application of hardware.
In areas where fasteners are not exposed, use aluminum, non-magnetic stainless steel, or other materials warranted by the manufacturer.
For exposed locations, provide countersunk Phillips head screws when items with a matching finish are fastened. For concealed locations, provide the manufacturer's standard fasteners.
SECTION 08 41 13 Page 7
Provide nuts or washers that have been designed with a means to prevent disengagement; do not deform fastener threads.
2.4.2 Perimeter Anchors
When steel anchors are used, provide insulation between steel material and aluminum material to prevent galvanic action.
2.4.2.1 Inserts and Anchorage Devices
Provide manufacturer's standard formed or fabricated assemblies, steel or aluminum, of shapes, plates, bars, or tubes. Shop-coat steel assemblies after fabrication with an alkyd zinc chromate primer complying with
FS TT-P-645 .
2.4.3 Standard Entrance Hardware
2.4.3.1 Panic Device
Provide the manufacturer's recommended standard panic hardware.
2.4.3.2 Closer
Provide a surface closer in accordance with ANSI/BHMA A156.4 .
2.4.3.3 Security Lock or Dead Lock
Provide A/R MS 1850A lock with two A/R 1871 cylinder operated flush bolts
2.4.3.4 Cylinder(s)/Thumb-turn
Provide the manufacturer's recommended standard.
2.4.3.5 Cylinder Guard
Provide the manufacturer's recommended standard.
PART 3 EXECUTION
3.1 EXAMINATION
3.1.1 Site Verification of Conditions
Verify that the condition of substrate previously installed under other sections is acceptable for product installation in accordance with the manufacturer's instructions.
Verify that openings are sized to receive the storefront system and that the sill plate is level in accordance with the manufacturer's acceptable tolerances.
3.2 PREPARATION
Field-verify dimensions before fabricating components for the door portal assembly.
Coordinate the erection of door portal with installation of surrounding glass wall and door assemblies. Ensure that the door portals can provide support and anchorage for assembly components.
SECTION 08 41 13 Page 8
3.2.1 Adjacent Surfaces Protection
Protect adjacent work areas and finish surfaces from damage during product installation.
3.2.2 Aluminum Surface Protection
Protect aluminum surfaces from contact with lime, mortar, cement, acids, and other harmful contaminants.
3.3 INSTALLATION
Submit installation drawings for review and approval.
Install the entrance system in accordance with the manufacturer's instructions and the AAMA storefront and entrance guide specifications manual. Attach the entrance system to the structure, allowing it to be adjusted to accommodate construction tolerances and other irregularities.
Provide alignment attachments and shims to permanently fasten the system to the building structure. Align the assembly so that it is plumb and level, and free of warp and twist. Maintain assembly dimensional tolerances aligning with adjacent work.
Set thresholds in a bed of mastic and secure the thresholds. Protect aluminum members in contact with masonry, steel, concrete, or dissimilar materials using nylon pads or a bituminous coating. Shim and brace the aluminum system before anchoring the system to the structure. Verify that weep holes are open, and the metal joints are sealed in accordance with the manufacturer's installation instructions. Seal metal-to-metal joints using a sealant recommended by the system manufacturer.
3.3.1 Tolerances
Ensure that tolerances for wall thickness and other cross-sectional dimensions of entrance members are nominal and in compliance with Aluminum Standards and Data, published by the Aluminum Association.
3.3.2 Adjusting
Adjust operating hardware for smooth operation, and as recommended by the manufacturer.
3.3.3 Related Products Installation Requirements
3.3.3.1 Sealants (Perimeter)
Refer to Section 07 92 00 JOINT SEALANTS.
3.3.3.2 Glass
Refer to Section 08 81 00 GLAZING.
3.4 WARRANTY
Submit three signed copies of the manufacturer's product warranty for the entrance system as follows:
SECTION 08 41 13 Page 9
a. Warranty Period: Five years from Date of Substantial Completion of the project, provided that the Limited Warranty begins no later than 6 months from the date of shipment by the manufacturer. In addition, support welded door corner construction with a limited lifetime warranty for the life of the door under normal use.
Ensure that the Warranty's language is identical to the "As Approved" version of the sample warranty submitted to and returned from the Contracting Officer.
-- End of Section --
SECTION 08 41 13 Page 10
SECTION 08 81 00
GLAZING
05/19
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM C509 (2006; R 2021) Standard Specification for Elastomeric Cellular Preformed Gasket and Sealing Material
ASTM C864 (2005; R 2015) Dense Elastomeric Compression Seal Gaskets, Setting Blocks, and Spacers
ASTM C920 (2018) Standard Specification for Elastomeric Joint Sealants
ASTM C1036 (2021) Standard Specification for Flat Glass
ASTM C1048 (2018) Standard Specification for Heat-Strengthened and Fully Tempered Flat Glass
ASTM C1184 (2023) Standard Specification for Structural Silicone Sealants
ASTM D395 (2016; E 2017) Standard Test Methods for Rubber Property - Compression Set
ASTM D2287 (2019) Nonrigid Vinyl Chloride Polymer and Copolymer Molding and Extrusion Compounds
GLASS ASSOCIATION OF NORTH AMERICA (GANA)
GANA Glazing Manual (2008) Glazing Manual
GANA Sealant Manual (2008) Sealant Manual
GANA Standards Manual (2008) Engineering Standards Manual
INSULATING GLASS MANUFACTURERS ALLIANCE (IGMA)
IGMA TB-3001 (2001) Guidelines for Sloped Glazing
IGMA TM-3000 (1990; R 2016) North American Glazing Guidelines for Sealed Insulating Glass Units for Commercial & Residential Use
SECTION 08 81 00 Page 1
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
16 CFR 1201 Safety Standard for Architectural Glazing Materials
1.2 SUBMITTALS
Government approval is required for submittals with a "G" classification.
Submittals not having a "G" classification are for Contractor Quality Control approval. Submittals not having a "G" classification are for information only. When used, a code following the "G" classification identifies the office that will review the submittal for the Government.
Submit the following in accordance with Section 01 33 00 SUBMITTAL
PROCEDURES:
SD-03 Product Data
Glazing Accessories
Manufacturer's descriptive product data, handling and storage recommendations, installation instructions, and cleaning instructions.
SD-04 Samples
Glazing Compound
Glazing Tape
Sealing Tapes
SD-08 Manufacturer's Instructions
Setting and Sealing Materials
Glass Setting
Submit glass manufacturer's recommendations for setting and sealing materials and for installation of each type of glazing material specified.
1.3 DELIVERY, STORAGE, AND HANDLING
Deliver products to the site in unopened containers, labeled plainly with manufacturers' names and brands. Store glass and setting materials in safe, enclosed dry locations and do not unpack until needed for installation. Handle and install materials in a manner that will protect them from damage.
1.4 ENVIRONMENTAL REQUIREMENTS
Do not start glazing work until the outdoor temperature is above 40 degrees F and rising, unless procedures recommended by the glass manufacturer and approved by the Contracting Officer are made to warm the glass and rabbet surfaces. Provide ventilation to prevent condensation of moisture on glazing work during installation. Do not perform glazing work during damp or rainy weather.
SECTION 08 81 00 Page 2
PART 2 PRODUCTS
2.1 GLASS
ASTM C1036, unless specified otherwise. In doors and sidelights, provide safety glazing material conforming to 16 CFR 1201 .
2.1.1 Clear Glass
Type I, Class 1 (clear), Quality q7. Provide for glazing openings not indicated or specified otherwise. Use double-strength sheet glass or 1/8 inch float glass for openings up to and including 15 square feet, 3/16 inch for glazing openings over 15 square feet but not over 30 square feet, and 1/4 inch for glazing openings over 30 square feet but not over 45 square feet.
2.1.2 Tempered Glass
ASTM C1048, Kind FT (fully tempered), Condition A (uncoated), Type I, Class 1 (transparent), Quality q7, 1/4 inch thick, conforming to ASTM C1048 and GANA Standards Manual . Color must be clear.
2.2 SETTING AND SEALING MATERIALS
Provide as specified in the GANA Glazing Manual , IGMA TM-3000 , IGMA TB-3001 , and manufacturer's recommendations, unless specified otherwise herein. Do not use metal sash putty, nonskinning compounds, nonresilient preformed sealers, or impregnated preformed gaskets. Materials exposed to view and unpainted must be gray or neutral color.
2.2.1 Putty and Glazing Compound
Provide glazing compound as recommended by manufacturer for face-glazing metal sash. Putty must be linseed oil type.
2.2.2 Glazing Compound
Use for face glazing metal sash.
2.2.3 Sealants
Provide elastomeric and structural sealants.
2.2.3.1 Elastomeric Sealant
ASTM C920, Type S, Grade NS, Class 12.5, Use G. Use for channel or stop glazing metal sash. Sealants must be chemically compatible with setting blocks, edge blocks, and sealing tapes. Color of sealant must be white.
2.2.3.2 Structural Sealant
ASTM C1184, Type S.
2.2.4 Joint Backer
Joint backer must have a diameter size at least 25 percent larger than
SECTION 08 81 00 Page 3 joint width; type and material as recommended in writing by glass and sealant manufacturer.
2.2.5 Glazing Tapes
2.2.6 Sealing Tapes
Preformed, semisolid, PVC-based material of proper size and compressibility for the particular condition, complying with ASTM D2287.
Use only where glazing rabbet is designed for tape and tape is recommended by the glass or sealant manufacturer. Provide spacer shims for use with compressible tapes. Tapes must be chemically compatible with the product being set.
2.2.7 Setting Blocks and Edge Blocks
Closed-cell neoprene setting blocks must be dense extruded type conforming to ASTM C509 and ASTM D395, Method B, Shore A durometer between 70 and
90. Edge blocking must be Shore A durometer of 50 (plus or minus 5).
Provide silicone setting blocks when blocks are in contact with silicone sealant. Profiles, lengths and locations must be as required and recommended in writing by glass manufacturer. Block color must be black.
2.2.8 Glazing Gaskets
Glazing gaskets must be extruded with continuous integral locking projection designed to engage into metal glass holding members to provide a watertight seal during dynamic loading, building movements and thermal movements. Glazing gaskets for a single glazed opening must be continuous one-piece units with factory-fabricated injection-molded corners free of flashing and burrs. Glazing gaskets must be in lengths or units recommended by manufacturer to ensure against pull-back at corners.
Provide glazing gasket profiles as recommended by the manufacturer for the intended application.
2.2.8.1 Fixed Glazing Gaskets
Fixed glazing gaskets must be closed-cell (sponge) smooth extruded compression gaskets of cured elastomeric virgin neoprene compounds conforming to ASTM C509, Type 2, Option 1.
2.2.8.2 Wedge Glazing Gaskets
Wedge glazing gaskets must be high-quality extrusions of cured elastomeric virgin neoprene compounds, ozone resistant, conforming to ASTM C864, Option 1, Shore A durometer between 65 and 75.
2.2.8.3 Aluminum Framing Glazing Gaskets
Glazing gaskets for aluminum framing must be permanent, elastic, non-shrinking, non-migrating, watertight and weathertight.
2.2.9 Accessories
Provide as required for a complete installation, including glazing points, clips, shims, angles, beads, and spacer strips. Provide noncorroding metal accessories. Provide primer-sealers and cleaners as recommended by the glass and sealant manufacturers.
SECTION 08 81 00 Page 4
PART 3 EXECUTION
Any materials that show visual evidence of biological growth due to the presence of moisture must not be installed on the building project. 3.1
PREPARATION
Preparation, unless otherwise specified or approved, must conform to applicable recommendations in the GANA Glazing Manual , GANA Sealant Manual , IGMA TB-3001 , IGMA TM-3000 , and manufacturer's recommendations. Determine the sizes to provide the required edge clearances by measuring the actual opening to receive the glass. Grind smooth in the shop glass edges that will be exposed in finish work. Leave labels in place until the installation is approved, except remove applied labels on heat-absorbing glass and on insulating glass units as soon as glass is installed.
Securely fix movable items or keep in a closed and locked position until glazing compound has thoroughly set.
3.2 GLASS SETTING
Shop glaze or field glaze items to be glazed using glass of the quality and thickness specified or indicated. Glazing, unless otherwise specified or approved, must conform to applicable recommendations in the GANA Glazing Manual , GANA Sealant Manual , IGMA TB-3001 , IGMA TM-3000 , and manufacturer's recommendations. Aluminum windows, wood doors, and wood windows may be glazed in conformance with one of the glazing methods described in the standards under which they are produced, except that face puttying with no bedding will not be permitted. Handle and install glazing materials in accordance with manufacturer's instructions. Use beads or stops which are furnished with items to be glazed to secure the glass in place. Verify products are properly installed, connected, and adjusted.
3.2.1 Sheet Glass
Cut and set with the visible lines or waves horizontal.
3.2.2 Vinyl Glass Film
Refer to drawings for frosted vinyl glass film design. Frosted vinyl glass film is to be installed on interior room side of glazing.
3.3 CLEANING
Clean glass surfaces and remove labels, paint spots, putty, and other defacement as required to prevent staining. Glass must be clean at the time the work is accepted.
3.4 PROTECTION
Protect glass work immediately after installation. Identify glazed openings with suitable warning tapes, cloth or paper flags, attached with non-staining adhesives. Protect reflective glass with a protective material to eliminate any contamination of the reflective coating. Place protective material far enough away from the coated glass to allow air to circulate to reduce heat buildup and moisture accumulation on the glass.
Upon removal, separate protective materials for reuse or recycling.
Remove and replace glass units which are broken, chipped, cracked, abraded, or otherwise damaged during construction activities with new units.
SECTION 08 81 00 Page 5
-- End of Section --
SECTION 08 81 00 Page 6
| Design Revision 01 |
| Drawings: |
| Noted Revisions are not included in sheets & specification sections that have been added or re-issued. Please make the following modifications to the drawing set: |
| On NAVFAC Drawing No. - 12,928,009 (AE409) |
| On NAVFAC Drawing No. - 12,928,029 (AF601) |
| On NAVFAC Drawing No. - 12,928,099 (EP401) |
| On NAVFAC Drawing No. - 12,928,100 (EP402) |
File details come from the government source that posted it. Updated .