AMENDMENT 0010.pdf
PDF 381 KB Posted
- Solicitation number
- N4008524R2531
About this file
This is Amendment 0010 to solicitation N4008524R2531 for the Design-Build-Build P-226 Maintenance Facility & Marine Air Group Headquarters at Marine Corps Air Station, Cherry Point, North Carolina. The amendment was issued on December 9, 2024 by NAVFACSYSCOM Mid-Atlantic.
The amendment provides responses to pre-proposal inquiries regarding technical specifications, particularly related to RF shielding requirements and cyber security controls. Key clarifications include: the Radiant Barrier Foil's 67 dB requirement across 100MHz to 10GHz applies to material specifications only; the RF-shielding design should achieve 65dB reduction over 30 MHz to 6GHz through combined materials and standoff; and security controls have been identified and incorporated into the design, with confirmation that separate Risk Management Framework (RMF) documentation is not required. The proposal due date remains December 13, 2024 at 2:00 PM EST.
View the file
Other files
Show all 33
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provi ded herei n, all t erms and condit ions of t he document refere nced in Item 9A or 10A, as heretofore change d, remai ns unchanged and in ful l force and effect .
15A. NAME AND TIT LE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
ST ANDARD FORM 30 (Rev. 10-83) Prescr ibed by GSA
FAR (48 CFR) 53.243
SOLICITATION NO. N4008524R2531 DESIGN-BID-BUILD, P-226 MAINTENANCE FACILITY & MARINE AIR GROUP HEADQUARTERS, MARINE
CORPS AIR STATION, CHERRY POINT, NORTH CAROLINA
The proposal due date of 13 December 2024 NLT than 1400 (EST) remains unchanged.
SEE SF 30 BLOCK 14 CONTINUATION PAGE
1. CO NTRACT ID CODE P AGE OF P AGES
J 1 3
16A. NAME AND T ITLE OF CONTRACTING OFFICER (Type or print)
16C. DAT E SIGNED
BY 09-Dec-2024
16B. UNITED ST AT ES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contract ing Officer )(Signature of person authorized t o sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, Count y, Stat e and Zip Code) X N4008524R2531
X 9B. DAT ED (SEE IT EM 11)
30-Aug-2024
10B. DAT ED (SEE IT EM 13)
9A. AMENDMENT OF SOLICITAT ION NO.
11. THIS IT EM ONLY APPLIES T O AMENDMENT S OF SOLICITATIONS
X The above numbered soli cit ati on i s amended as set forth in It em 14. The hour and date specified for rece ipt of Offer is ext ended, X is not extended.
Offer must acknowl edge rece ipt of t his amendment pri or to the hour and date specified in the sol ici tat ion or as amended by one of t he fol lowing methods:
(a) By compl eti ng Items 8 and 15, and returning copi es of the amendment ; (b) By acknowledgi ng recei pt of thi s a mendment on each copy of t he offer submit ted;
or (c) By s epara te let ter or t elegram whi ch i ncludes a refe rence t o t he s olic ita tion and amendment numbers . FA ILURE OF YOU R A CKNOWLEDGMENT TO BE RECEIVED AT TH E P LACE D ESIGNATED FOR TH E RECEIPT OF OFFERS P RIO R TO THE HOUR AN D DATE SP ECIFIED MA Y RESULT IN
REJECTIO N OF YOUR OFFER. If by vir tue of thi s amendment you desire t o change an offer already submit ted, s uch c hange ma y be made by t ele gram or let ter, provided each t elegram or l ett er makes reference to the sol ici tat ion and this amendment , and is re ceived prior to the openi ng hour and dat e speci fi ed.
12. ACCOUNTING AND APPROPRIATION DAT A (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORT H IN ITEM 14 ARE MADE IN THE
CONT RACT ORDER NO. IN ITEM 10A.
B. T HE ABOVE NUMBERED CONT RACT /ORDER IS MODIFIED T O REFLECT THE ADMINIST RATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORT H IN ITEM 14, PURSUANT TO T HE AUTHORITY OF FAR 43.103(B).
C. T HIS SUPPLEMENT AL AGREEMENT IS ENT ERED INTO PURSUANT TO AUTHORITY OF:
D. OT HER (Specify type of modification and authorit y)
E. IMPORTANT: Contract or is not, is required to sign this document and return copies t o the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/cont ract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/ MODIFICATION NO. 5. P ROJECT NO .(If appli cable)
6. ISSUED BY
3. EFFECTIVE DATE
09-Dec-2024
CODE
NAVFACSYSCOM MID-ATLANTIC
CONTRACTING CORE
9324 VIRGINIA AVENUE
NORFOLK VA 23511- 3095
N40085 7. AD MINISTERED BY (If other t han item 6)
4. REQUISITION/PU RCHASE REQ. NO.
CODE
See I tem 6
FACILITY CODECODE
EMAIL:TEL:
N4008524R2531
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 30 - BLOCK 14 CONTINUATION PAGE (SF 30)
The following have been added by full text:
AMENDMENT 0010
The purpose of this amendment is to provide the following:
1. Responses to Pre-Proposal Inquiries (PPI’s)
Pre-Proposal Inquiry Responses:
Question # Reference
Question Government Response Page Section Paragraph
01 57 19
- 1.5, 01 14 00 -
1.2
01 57 19 - 1.5, 01 14 00 - 1.2
General-01 57 19 - 1.5, 01 14 00 - 1.2-Specification 13 47 00 Section 2.1 states the Radiant Barrier Foil is to achieve 67 dB across the frequency range of 100MHz to 10GHz. Please confirm this applies to the material only and not the RF-shield system as a whole.
Part two of UFGS specifications provide the material requirements for the item specified.
126 13 47 00 13 47 00
Architectural-13 47 00- Specification 13 47 00 Section
3.2 calls for 100 meters of free space over the frequency range of 30 MHz to 6 GHz. Please clarify how much isolation (measured in decibels) is required across this frequency range. The current design has many points of failure that prevent isolation (measured in decibels) from being guaranteed across that frequency range. Please confirm that the current design does not require the contractor to guarantee RF-shielding performance.
The design is intended to achieve radio frequency attenuation through a combination of materials and standoff that is equal to 65dB reduction over the frequency range of 30 MHz to 6GHz. Provide and install all materials conforming to the specifications and installed in accordance with the manufacture’s guidance to ensure optimal performance.
127 13 47 00 13 47 00
Architectural-13 47 00- Specification 13 47 00 Section
3.2 calls for 100 meters of free space over the frequency range of 30 MHz to 6 GHz. Please clarify how much isolation (measured in decibels) is required across this frequency range. The current design has many points of failure that prevent isolation (measured
See response to PPI#126.
N4008524R2531 in decibels) from being guaranteed across that frequency range. Please confirm that the current design does not require the contractor to guarantee RF-shielding performance.
25 05 11 Please verify Risk Management Framework (RMF) is not required for Cyber Security. It does not appear to be required per the specification provided as this is normally in UFGS 25 08 11.00 20.
The security controls have been identified and incorporated in the security controls into the design.
25 05 11 25 05 11: please verify Risk Management Framework (RMF) is not required for Cyber Security.
It does not appear to be required per the specification provided as this is normally in UFGS 25 08
11.00 20.
See response to PPI #155.
(End of Summary of Changes)