This solicitation is for an 8A MACC, DB/DBB General Construction contract in the Hampton Roads Area of Responsibility. The contract will result in multiple awards for construction services including demolition, repair, replacement, modification, new construction, and renovation of buildings, systems and infrastructure at various Navy and NASA facilities. Work will include projects such as building envelope, fire protection, plumbing, mechanical and electrical renovations, as well as elevators, waterfront structures, and tanks. The contract will require management of concurrent task orders across the Hampton Roads area. The Contractor shall provide all labor, materials, equipment and transportation to perform the services described in task order plans and specifications.
View the file
Other files for this federal contract opportunity
Show all 27
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DOOR NUMBER
(REFER TO DOOR SCHEDULE)
DOOR TAG
ARCHITECTURAL SYMBOLS
ROOM
A1 A-301
- - - - - - - - - - - - - - - - - - - - - - - - - - - - ROOM TAG
DETAIL NUMBER
SHEET WHERE DRAWN
DETAIL TAG
ROOM NAME
ROOM NUMBER
EXTERIOR ELEVATION
TAG
ELEVATION NUMBER
DIRECTION OF VIEW
SHEET WHERE DRAWN
A1 A-301
WALL / PARTIAL
BUILDING SECTION
TAG
SECTION NUMBER
SHEET WHERE DRAWN
NEW WORK
KEYNOTE TAG
KEYNOTE NUMBER
DEMO
KEYNOTE TAG
KEYNOTE NUMBER
A-501
1 1
CJ
EJ
MASONRY
CONTROL JOINT
BUILDING
EXPANSION JOINT
JOINT TAG ±(10'-0") CEILING HEIGHT
KEYNOTE TAG
CEILING HEIGHT TAG
MATERIALS LEGEND
CONCRETE MASONRY UNIT
CAST-IN-PLACE CONCRETE
STEEL
BATT/LOOSE FILL INSULATION
RIGID INSULATION
WOOD - ROUGH
WOOD BLOCKING
SECTION ELEVATION
BRICK - NEW WORK
GLAZING
SPANDREL GLAZING / STEEL PANEL
CONCRETE FOUNDATION
EARTH / COMPACT FILL
POROUS FILL / GRAVEL
ALUMINUM
BRICK
GYPSUM BOARD
PLYWOOD
SAND / MORTAR / PLASTER
ACOUSTICAL TILE CEILING
CERAMIC TILE
FINISHED WOOD
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
DRAWFORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
C O
M M
AN
D
M
ID
-A
TL
AN
TI
C
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
UN
CL
AS
SI
FI
ED
PW
D
N O
R
FO
LK
A-001
B U
IL
D
IN
G
S P
-2
AR
CH
IT
EC
TU
RA
L
NO
TE
S
AN
D
SY
M
BO
LS
LAB
12,820,992
SAR SAR
02/15/21
MICHAEL COMPTON, CNATTU
EX
TE
RI
O
R
RE
PA
IR
S
RO
O
F
RE
NO
VA
TI
O
N
SEBASTIAN A. RAMOS, R.A.
1576521
N/A
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
TA
TI
ON
S. M. SWEENEY, P.E.
1 ALL WOOD BLOCKING AND MISCELLANEOUS STEEL SHOWN IN DETAILS AND
SECTIONS MUST BE CONTINUOUS UNLESS SPECIFICALLY NOTED
OTHERWISE.
2 VERIFY ALL FIELD CONDITIONS AND DIMENSIONS PRIOR TO PROCEEDING
WITH THE WORK. DIMENSIONS FOR EXISTING WORK ARE INDICATED AS "±".
ALL DISCREPANCIES MUST BE BROUGHT TO THE IMMEDIATE ATTENTION OF
THE CONTRACTING OFFICER IN WRITING.
3 DEMOLITION OF CIVIL, STRUCTURAL, FIRE PROTECTION, AND ELECTRICAL
ITEMS INDICATED ON THE ARCHITECTURAL DRAWINGS ARE NOT INTENDED
TO INCLUDE ALL NECESSARY DEMOLITION WORK FOR THESE ITEMS. REFER
TO CIVIL, STRUCTURAL, AND ELECTRICAL DEMOLITION DRAWINGS FOR
ADDITIONAL INFORMATION.
4 DIMENSIONS INDICATED FOR NEW WORK ARE TO FACE OF STUD, FACE OF
MASONRY OR FACE OF EXISTING SURFACES UNLESS OTHERWISE NOTED.
5 ALL MATERIALS/PRODUCTS MUST BE INSTALLED PER MANUFACTURER'S
INSTALLATION REQUIREMENTS.
6 NO FINISH MATERIALS MUST BE SUBSTITUTED DUE TO ORDERING LEAD
TIMES. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ORDER ALL MATERIALS
IN A TIMELY FASHON TO AVOID DELAYS.
7 REFER TO GENERAL PROJECT NOTES ON SHEET G-002 FOR ADDITIONAL
INFORMATION.
SF SQUARE FOOT
SH SHINGLES / SINGLE HUNG
SIM SIMILAR
SPC SUSPENDED PLASTER CEILING
SPEC SPECIFICATION
SQ SQUARE
STD STANDARD
STOR STORAGE
STR STRAIGHT STRIKE / STRINGERS
SUSP SUSPENDED
T&B TOP AND BOTTOM
TEL TELEPHONE
THRES THRESHOLD
THRU THROUGH
TOJ TOP OF JOIST
TOS TOP OF SLAB / STEEL
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
V VOLT
VAR VARIATION
VB VINYL BASE
VCT VINYL COMPOSITION TILE
VENT VENTILATION / VENTILATOR
VERT VERTICAL
VEST VESTIBULE
VS VENT STACK
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
W WASTE / WATT / WEST / WIDE
W/ WITH
W/O WITHOUT
WC WATER CLOSET / WALL COVERING
WD WOOD
WH WATER HEATER
WP WATERPROOFING / WEATHERPROOF / WORKING
POINT
WSCT WAINSCOT
WT WEIGHT
WWF WELDED WIRE FABRIC
XRMR TRANSFORMER
NTS NOT TO SCALE
OA OUTSIDE AIR
OC ON CENTER
OD OUTSIDE DIAMETER / DIMENSION
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPT OPTIONAL
PCT PERCENT
PEJ PREMOLDED EXPANSION JOINT
PL PROPERTY LINE
PLAS PLASTER / PLASTIC
PLYWD PLYWOOD
PNL PANEL
PRELIM PRELIMINARY
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT
PV PIPE VENT
QT QUARRY TILE
R RADUIS / RISER
RA RETURN AIR
RAD RETURN AIR DUCT
RB RESILIENT BASE
RD ROOF DRAIN / ROAD
REFL REFLECT
REFR REFRIGERATION
REINF REINFORCE
REQD REQUIRED
REV REVISION
RF RESILIENT FLOORING
RL ROOF LEADER
RM ROOM
RND ROUND
RO ROUGH OPENING
RS ROUGH SAWN
RT RIGHT
S SOUTH
SAPC SUSPENDED ACOUSTICAL PANEL CEILING
SCHED SCHEDULE
SECT SECTION
GALV GALVANIZED
GFCI GOVERNMENT FURNISHED CONTRACTOR INSTALLED
GL GLASS / GROUND LEVEL
GR GROSS
GSU GLAZED STRUCTURAL UNIT
GV GRAVITY VENTILATOR
GWB GYPSUM WALLBOARD
GYP GYPSUM
H HIGH
HB HOSE BIB
HDW HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HT HEIGHT
HVY HEAVY
ID INSIDE DIAMETER
INSUL INSULATION / INSULATED
INT INTERIOR
J-BOX JUNCTION BOX
JAN JANITOR CLOSET
LAV LAVATORY
LB POUND
LF LINEAR FEET
LT LIGHT
MACH MACHINE
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MFG MANUFACTURING
MIN MINIMUM / MINUTE
MISC MISCELLANEOUS
ML MATCH LINE
MO MASONRY OPENING / MOTOR OPERATED
MTD MOUNTED
MTG MOUNTING / MEETING
MTL METAL
MWP MEMBRANE WATERPROOFING
N NORTH
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
CT CERAMIC TILE
CTR CENTER
D DEPTH / DEEP
DEG DEGREE
DEMO DEMOLITION
DET DETAIL
DIA DIAMETER
DIM DIMENSION
DR DRAIN
DS DOWNSPOUT
DW DISHWASHER
DWG DRAWING
E EAST
EA EACH
EF EXHAUST FAN
EIFS EXTERIOR INSULATION & FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC / ELECTRICAL
EPDM ETHLENE PROPYLENE DIEN MONOMER
EQ EQUAL
EQUIP EQUIPMENT
EW EACH WAY
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION / EXPOSED / EXPAND
EXT EXTERIOR
FD FLOOR DRAIN
FDTN FOUNDATION
FF FINISH FACE
FG FIGURE
FHC FIRE HOUSE CABINET
FIN FLR FINISHED FLOOR
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF STUB / FACE OF SLAB
FR FRAME / FIRE RATING / FIRE RESISTANT
FT FOOT, FEET
FTG FOOTING
GA GAUGE
AB ANCHOR BOLT
ACS PNL ACCESS PANEL
ADJ ADJUST
ALT ALTERNATE, ALTITUDE
ALUM ALUMINUM
ANOD ANODIZED
APPROX APPROXIMATE
ARCH ARCHITECT
ASPH ASPHALT
ATC ACOUSTICAL TILE CEILING
BD BOARD
BLDG BUILDING
BLW BELOW
BM BEAM
BOS BOTTOM OF SLAB / STEEL
BOT BOTTOM
BRG BEARING
BSMT BASEMENT
BTWN BETWEEN
C TO C CENTER TO CENTER
CAB CABINET
CEM CEMENT
CER CERAMIC
CI CAST IRON
CIP CAST IRON PIPE
CJ CONTROL / CONSTRUCTION JOINT
CLG CEILING
CLG REG CEILING REGISTER
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CND CONDUIT
CNDS CONDENSATE
CNSTR CONSTRUCTION
CNTR CNTR
CO CLEANOUT
COL COLUMN
CONC CONCRETE
CONN CONNECT
CONT CONTINUE / CONTINUOUS
CORR CORRIDOR
CPT CARPET / COMMON PATH OF TRAVEL
ARCHITECTURAL ABBREVIATIONS
GENERAL ARCHITECTURAL NOTES
SY
M
DE
S C
RI
PT
I O N
DA
TE
AP
PR
UP
UP
UP
K
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 2423
J
H
G
F
E
D
C
B
A
MA
TC
HL
IN
E -A
RE
A
'A
MA
TC
HL
IN
E -A
RE
A
'B
B1
AD201
C1
AD202
A1
AD202
A1
AD301
6 6
2 3 2 3
2 3
6 6
1'-7 1/8" ± 60'-9" ± 9'-1 1/2" ± 17'-2 1/4" ± 9'-1 1/2" ± 60'-9" ± 23'-9 5/8" ± 7'-8" ±
340'-0" ±
'-2
1'- 2 1
/8"
1'-7 1/8" ± 65'-9 3/4" ± 25'-4" ±
65'-9" ± 1'-4" ± 30'-1" ±
3'-
1'-
0 1 /2"
2'- 6 7
/8"
2'- 6 7
/8"
1'- 0 5
/8"
22'-3" ±
11 11
11 11
11 11
D2
AD203
C3
AD203
C4
AD203
C5
AD203
D1
AD203
B1
AD203 3 3
ABOVE
BELOW
ABOVE
BELOW
ABOVE
BELOW
ABOVE
BELOW
'-0
3/ 4"
4'-2" ±
1 2 2 2
2 2
5 5
15 15
15 15
191919
12 12
A2
AD301
A4
AD301
A3
AD301
A1
AD301
- - - - - - - - - - - - - - - - - - - - - - - - - - - - A1
AD302
A2
AD302
AD102
C1
K
20 21 22 2423 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
J
H
G
F
E
D
C
B
A
MA
TC
HL
IN
E -A
RE
A
'A
MA
TC
HL
IN
E -A
RE
A
'B
C1
AD201
A1
AD201
B1
AD202
2 3
6 6
2 3
2 3
6 6
2 3
'-2
62'-5 1/8" ± 25'-3 3/4" ± 60'-9" ± 1'-7 1/8" ±
340'-0" ±
8'- 6"
1'- 0 7
/8"
55'-8 1/4" ± 9'-1 1/2" ± 17'-2 1/4" ± 9'-1 1/2" ± 55'-8 1/4" ± 1'-7 1/8" ±
8'- 6 5
/8"
2'- 6 1
/4"
2'- 6 1
/4"
1'- 1 1
/8"
1'-7 1/8" ±
11 11
11 11 11 11 11
D4
AD203
D5
AD203
C1
AD203
D3
AD203
C2
AD203
ABOVE
BELOW
ABOVE
BELOW
ABOVE
BELOW
ABOVE
BELOW
1'-8 3/8" ±
2 2
5 5
15 15
19191919
19191919
20 21
12 12
A2
AD301
A3
AD301
A1
AD301
A1
AD301
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
DRAWFORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
C O
M M
AN
D
M
ID
-A
TL
AN
TI
C
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
UN
CL
AS
SI
FI
ED
PW
D
N O
R
FO
LK
AD101
B U
IL
D
IN
G
S P
-2
FI
RS
T
FL
O O
R
PL
AN
DE
M
O
LI
TI
O
N
LAB
12,820,993
SAR SAR
02/15/21
MICHAEL COMPTON, CNATTU
EX
TE
RI
O
R
RE
PA
IR
S
RO
O
F
RE
NO
VA
TI
O
N
SEBASTIAN A. RAMOS, R.A.
1576521
N/A
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
TA
TI
ON
S. M. SWEENEY, P.E.
0 4' 8' 16'
PLAN
NORTH
SCALE: 1/8" = 1'-0"
PARTIAL FIRST FLOOR DEMOLITION PLAN - AREA 'A'
0 4' 8' 16'
PLAN
NORTH
SCALE: 1/8" = 1'-0"
PARTIAL FIRST FLOOR DEMOLITION PLAN - AREA 'B'
1 REFER TO OTHER PORTIONS OF THE CONTRACT DOCUMENTS FOR
ADDITIONAL INFORMATION AND INSTRUCTIONS.
2 REFER TO SHEET AD102 FOR DEMOLITION KEYNOTES SCHEDULE.
3 EXISTING FAN COIL UNITS TO REMAIN. PROTECT UNITS THROUGHOUT
DEMOLITION AND RENOVATION WORK.
GENERAL SHEET NOTES
SY
M
DE
S C
RI
PT
I O N
DA
TE
SE
E
ST
RU
C T . D
RA
W
IN
GS
8" ± T
O 1'-
4"
REMOVE EXTERIOR BRICK
VENEER WALL COMPLETE.
EXISTING INTERIOR CMU
WALL TO REMAIN
REMOVE DAMAGED AND
CRACKED INTERIOR CMU WALL
FULL HEIGHT TO EXTENTS
SHOWN TO ALLOW FOR
INSTALLATION OF 1" EXPANSION
JOINT - SEE STRUCTURAL
DRAWINGS.
EXISTING INTERIOR CMU
WALL TO REMAIN
AIR GAP
STEEL COLUMN AND METAL
COLUMN COVER TO REMAIN
REMOVE PRECAST CONCRETE
WINDOW SILL
REMOVE PLASTIC
LAMINATE WINDOW SILL
CONSTRUCTION
COMPLETE
REMOVE ALUMINUM
WINDOW SYSTEM
COMPLETE AND SALVAGE
FOR REINSTALLATION
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
DRAWFORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
C O
M M
AN
D
M
ID
-A
TL
AN
TI
C
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
UN
CL
AS
SI
FI
ED
PW
D
N O
R
FO
LK
AD102
B U
IL
D
IN
G
S P
-2
FI
RS
T
FL
O O
R
PL
AN
DE
M
O
LI
TI
O
N -K
EY
NO
TE
S
LAB
12,820,994
SAR SAR
02/15/21
MICHAEL COMPTON, CNATTU
EX
TE
RI
O
R
RE
PA
IR
S
RO
O
F
RE
NO
VA
TI
O
N
SEBASTIAN A. RAMOS, R.A.
1576521
N/A
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
TA
TI
ON
S. M. SWEENEY, P.E.
1 EXISTING BRICK VENEER EXTERIOR WALL TO REMAIN.
2 REMOVE EXTERIOR BRICK VENEER WALL COMPLETE. EXISTING INTERIOR
CMU WALL TO REMAIN (FOR BIDDING PURPOSES ASSUME 9,979 SF TOTAL
EXTERIOR BRICK VENEER PER PROJECT).
3 REMOVE PRECAST CONCRETE WINDOW SILL COMPLETE (FOR BIDDING
PURPOSES ASSUME 1,073 LF TOTAL PRECAST CONCRETE WINDOW SILL PER
PROJECT).
4 REMOVE ALUMINUM STOREFRONT ENTRY SYSTEM COMPLETE AND SALVAGE
FOR REINSTALLATION (FOR BIDDING PURPOSES ASSUME 432 SF TOTAL
ALUMINUM STOREFRONT ENTRY SYSTEM PER PROJECT).
5 REMOVE PLANTER COMPLETE. REMOVE BRICK VENEER, CONCRETE CAP,
AND ALL ASSOCIATED COMPONENTS (FOR BIDDING PURPOSES ASSUME 159
SF TOTAL BRICK VENEER PLANTERS PER PROJECT).
6 REMOVE CONCRETE CANOPY AND ALL ASSOCIATED COMPONENTS
COMPLETE, INCLUDING TAPERED INSULATION, WOOD BLOCKING, METAL
COUNTERFLASHING, AND METAL GRAVEL STOP (FOR BIDDING PURPOSES
ASSUME 26.98 CY OF CONCRETE, 133 LF OF METAL GRAVEL STOP, 133 LF OF
WOOD BLOCKING, 86 LF OF METAL COUNTERFLASHING, 517 SF OF TAPERED
INSULATION, AND 517 SF OF BALLASTED ROOF GRAVEL TOTAL FOR
CONCRETE CANOPIES PER PROJECT).
7 EXISTING CONCRETE PAD TO REMAIN.
8 REMOVE EXTERIOR STAIR, RAILING, STEEL SUPPORT COLUMNS, FOOTINGS,
AND ALL ASSOCIATED COMPONENTS COMPLETE (FOR BIDDING PURPOSES
ASSUME 1 STAIR TOTAL PER PROJECT) - SEE STRUCTURAL DRAWINGS.
9 EXISTING HVAC UNIT TO REMAIN. PROTECT UNIT THROUGHOUT DURATION
OF CONSTRUCTION. DISCONNECT AND RECONNECT UNIT AS REQUIRED TO
COMPLETE RENOVATION WORK – SEE ELECTRICAL DRAWINGS. COORDINATE
HVAC DISCONNECTIONS AND RECONNECTIONS WITH COMMAND.
10 EXISTING NATURAL GAS METER TO REMAIN. PROTECT UNIT THROUGHOUT
DURATION OF CONSTRUCTION WORK. DISCONNECT AND RECONNECT UNIT
AS REQUIRED TO COMPLETE RENOVATION WORK. COORDINATE UTILITY
DISCONNECTIONS AND RECONNECTIONS WITH COMMAND.
11 REMOVE PLASTIC LAMINATE WINDOW SILL CONSTRUCTION COMPLETE.
PREPARE SURFACE FOR INSTALLATION OF NEW WINDOW SILL
CONSTRUCTION (FOR BIDDING PURPOSES, ASSUME 928 LF TOTAL OF
PLASTIC LAMINATE WINDOW SILL PER PROJECT).
12 REMOVE BUSHES AND ASSOCIATED PLANTER COMPLETE - SEE CIVIL
DRAWINGS.
13 REMOVE CONCRETE SLAB CONSTRUCTION TO EXTENTS SHOWN - SEE
STRUCTURAL DRAWINGS.
14 REMOVE CONCRETE SIDEWALK TO EXTENTS SHOWN - SEE CIVIL DRAWINGS.
15 REMOVE SURFACE MOUNTED ELECTRICAL AND TELECOMMUNICATIONS
WIREWAY AND RECEPTACLES COMPLETE AND SALVAGE FOR
REINSTALLATION. REMOVE AND SALVAGE EXISTING POWER AND DATA
WIRING - SEE ELECTRICAL DRAWINGS.
16 REMOVE ALUMINUM WINDOW SYSTEM COMPLETE AND SALVAGE FOR
REINSTALLATION. EXISTING STEEL STRUCTURE CONCEALED BY WINDOW
MULLIONS IS EXISTING TO REMAIN (FOR BIDDING PURPOSES ASSUME 7,290
SF TOTAL ALUMINUM WINDOW SYSTEM PER PROJECT).
17 REMOVE PAINT AND PREPARE SURFACE FOR NEW PAINT - SEE SHEETS
HM101 AND A-101.
18 REMOVE HOLLOW METAL FRAME AND DOOR SYSTEM COMPLETE (FOR
BIDDING PURPOSES ASSUME 5 HOLLOW METAL FRAME AND DOOR SYSTEMS
TOTAL PER PROJECT).
19 REMOVE CARPET AND WALL BASE COMPLETE. REMEDIATE EXPOSED
ASBESTOS TILE AND MASTIC - SEE SHEET HM101.
20 REMOVE 1/2" GWB OVER METAL FURRING WALL COMPLETE (FOR BIDDING
PURPOSES ASSUME 149 SF TOTAL WALL PER PROJECT).
21 REMOVE SURFACE MOUNTED RECEPTACLES AND ASSOCIATED CONDUITS,
SURFACE MOUNTED HVAC UNIT DISCONNECTS, AND CABLE TROUGH AND
SALVAGE FOR REINSTALLATION. PROVIDE TEMPORARY POWER FOR SERVER
ROOM HVAC UNITS AND SERVER EQUIPMENT THROUGHOUT DURATION OF
RENOVATION WORK. COORDINATE POWER DISCONNECTIONS AND
RECONNECTIONS WITH COMMAND - SEE ELEC. DWGS.
22 REMOVE DAMAGED AND CRACKED INTERIOR CMU WALL FULL HEIGHT TO
EXTENTS SHOWN TO ALLOW FOR INSTALLATION OF 1" EXPANSION JOINT
(FOR BIDDING PURPOSES, ASSUME 33 SF OF CMU WALL) - SEE STRUCTURAL
DRAWINGS.
23 REMOVE ABANDONED OVERHEAD DOORS COMPLETE (FOR BIDDING
PURPOSES ASSUME 2 TOTAL ABANDONED OVERHEAD DOORS PER
PROJECT).
24 TOOTH-OUT AND REMOVE EXISTING CUT INTERIOR CMU ADJACENT TO
ABANDONED OVERHEAD DOOR FRAME TO BE REMOVED.
DEMOLITION KEYNOTES
0 4" 8" 1'-4"SCALE: 1 1/2" = 1'-0" (AD101)
PLAN DETAIL - MECH. ROOM CORNER WALL - DEMOLITIONC1
SY
M
DE
S C
RI
PT
I O N
DA
TE
K
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 2423
J
H
G
F
E
D
C
B
A
MA
TC
HL
IN
E -A
RE
A
'A
MA
TC
HL
IN
E -A
RE
A
'B
±(8'-6")±(8'-6")
±(8'-6") ±(8'-6")±(8'-6")±(8'-6")
±(8'-6")±(8'-6")
±(8'-6")
2 2 2 1 2
211 1 1 1 2
3 3
3 3
2 2
66666
4'-9" ±
2'- 0"
± 6'-3 1/2" ±
2'- 0"
4'-9" ±
2'- 0"
2'- 0"
±(10'-0") ±(10'-0")
±(10'-0")
±(7'-6")
±(8'-0")
±(10'-0")
±(7'-6") ±(7'-6")
K
20 21 22 2423 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
J
H
G
F
E
D
C
B
A
MA
TC
HL
IN
E -A
RE
A
'A
MA
TC
HL
IN
E -A
RE
A
'B
±(8'-6")
±(8'-6")
±(10'-0")
±(8'-6")
±(8'-6")
±(8'-6")±(8'-6")
±(8'-6")
21 1
3 3
2 2 2
66666
2'- 0"
4'-9" ±
2'- 0"
6'-3 1/2" ±
2'- 0"
2'- 0"
4'-9" ±
'-3
5/ 8"
±(7'-6")
±(7'-6")
±(8'-0")
±(10'-0")
±(10'-0")
±(10'-0")
±(10'-0")
±(8'-6")
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
DRAWFORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
C O
M M
AN
D
M
ID
-A
TL
AN
TI
C
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
UN
CL
AS
SI
FI
ED
PW
D
N O
R
FO
LK
AD103
B U
IL
D
IN
G
S P
-2
FI
RS
T
FL
O O
R
RE
FL
EC
TE
D
CE
IL
IN
G
P
LA
N -D
EM
O
LI
TI
O N
LAB
12,820,995
SAR SAR
02/15/21
MICHAEL COMPTON, CNATTU
EX
TE
RI
O
R
RE
PA
IR
S
RO
O
F
RE
NO
VA
TI
O
N
SEBASTIAN A. RAMOS, R.A.
1576521
N/A
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
TA
TI
ON
S. M. SWEENEY, P.E.
0 4' 8' 16'
PLAN
NORTH
SCALE: 1/8" = 1'-0"
PARTIAL FIRST FLOOR REFLECTED CEILING DEMOLITION PLAN - AREA 'A'
0 4' 8' 16'
PLAN
NORTH
SCALE: 1/8" = 1'-0"
PARTIAL FIRST FLOOR REFLECTED CEILING DEMOLITION PLAN - AREA 'B'
GENERAL SHEET NOTES
DEMOLITION KEYNOTES
1 EXISTING ACOUSTICAL CEILING TILE GRID TO REMAIN.
2 REFER TO OTHER PORTIONS OF THE CONTRACT DOCUMENTS FOR
ADDITIONAL INFORMATION AND INSTRUCTIONS.
1 REMOVE 2' X 2' ACOUSTICAL CEILING TILE AS INDICATED (FOR BIDDING
PURPOSES ASSUME 132 SF TOTAL OF ACT PER PROJECT).
2 REMOVE GWB OVER PLASTER AND ACOUSTICAL PANEL CEILING TO EXTENTS
INDICATED - SEE SHEETS HM101 AND A-102 (FOR BIDDING PURPOSES
ASSUME 834 SF TOTAL GWB CEILING SURFACES PER PROJECT).
3 REMOVE ALUMINUM WINDOW SYSTEM COMPLETE AND SALVAGE FOR
REINSTALLATION. EXISTING STEEL STRUCTURE CONCEALED BY WINDOW
MULLIONS IS EXISTING TO REMAIN (FOR BIDDING PURPOSES ASSUME 7,290
SF TOTAL ALUMINUM WINDOW SYSTEM PER PROJECT).
4 REMOVE CONCRETE CANOPY AND ALL ASSOCIATED COMPONENTS
COMPLETE, INCLUDING TAPERED INSULATION, WOOD BLOCKING, METAL
COUNTERFLASHING, AND METAL GRAVEL STOP.
5 REMOVE PAINT AND PREPARE SURFACE FOR NEW PAINT - SEE SHEETS
HM101 AND A-101.
6 REMOVE WINDOW SHADES AND ALL ASSOCIATED COMPONENTS COMPLETE
(FOR BIDDING PURPOSES ASSUME 928 LF TOTAL PER PROJECT).
7 REMOVE 1' X 1' ACOUSTICAL CEILING TILE AS INDICATED (FOR BIDDING
PURPOSES ASSUME 217 SF TOTAL OF ACT PER PROJECT).
8 REMOVE ALUMINUM STOREFRONT ENTRY SYSTEM COMPLETE AND SALVAGE
FOR REINSTALLATION (FOR BIDDING PURPOSES ASSUME 432 SF TOTAL
ALUMINUM STOREFRONT ENTRY SYSTEM PER PROJECT).
SY
M
DE
S C
RI
PT
I O N
DA
TE
DN
DN
DN
K
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 2423
J
H
G
F
E
D
C
B
A
MA
TC
HL
IN
E -A
RE
A
'A
MA
TC
HL
IN
E -A
RE
A
'B
A1
AD301
22'-3" ±
3 2
340'-0" ± 1'-7 1/8" ± 60'-9" ± 9'-1 1/2" ± 17'-2 1/4" ± 9'-1 1/2" ± 60'-10 3/4" ± 31'-3 7/8" ±
'-2
1'- 2 1
/8"
1'-7 1/8" ± 65'-9 3/4" ± 25'-4" ±
67'-1 1/8" ± 30'-1" ±
3'-
1'-
0 1 /2"
1'-7 1/8" ±
1'-8 1/8" ±
6 7
2 ABOVE
BELOW2 ABOVE
BELOW
2 ABOVE
BELOW 2 ABOVE
BELOW 2 ABOVE
BELOW
4'-2" ±
'-0
3/ 4"
3 4
4 4 4 411 11 11
A2
AD301
A4
AD301
A3
AD301
A1
AD301
- - - - - - - - - - - - - - - - - - - - - - - - - - - - A1
AD302
A2
AD302
A1
AD501
AD102
C1
K
20 21 22 2423 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
J
H
G
F
E
D
C
B
A
MA
TC
HL
IN
E -A
RE
A
'A
MA
TC
HL
IN
E -A
RE
A
'B
2 3 3
32 4
340'-0" ±
8'- 6 5
/8"
1'-7 1/8" ± 55'-8 1/4" ± 9'-1 1/2" ± 17'-2 1/4" ± 9'-1 1/2" ± 55'-8 1/4" ± 1'-7 1/8" ±
1'- 1 1
/8"
2'- 6 1
/4"
2'- 6 1
/4"
8'- 6"
'-2
1'-8 1/8" ± 60'-9" 25'-3 3/4" ± 60'-9" ± 1'-7 1/8" ±
1'- 0 7
/8"
7 7 7
2 ABOVE
BELOW 2 ABOVE
BELOW 2 ABOVE
BELOW
2 ABOVE
BELOW2 ABOVE
BELOW
4 5
2 2
4 4 4 411 11 11
A2
AD301
- - - - - - - - - - - - - - - - - - - - - - - - - - - - A3
AD301
A1
AD301
A1
AD301
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
DRAWFORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
C O
M M
AN
D
M
ID
-A
TL
AN
TI
C
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
UN
CL
AS
SI
FI
ED
PW
D
N O
R
FO
LK
AD104
B U
IL
D
IN
G
S P
-2
SE
CO
ND
F
LO
O
R
PL
AN
DE
M
O
LI
TI
O
N
LAB
12,820,996
SAR SAR
02/15/21
MICHAEL COMPTON, CNATTU
EX
TE
RI
O
R
RE
PA
IR
S
RO
O
F
RE
NO
VA
TI
O
N
SEBASTIAN A. RAMOS, R.A.
1576521
N/A
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
TA
TI
ON
S. M. SWEENEY, P.E.
0 4' 8' 16'
PLAN
NORTH
SCALE: 1/8" = 1'-0"
PARTIAL SECOND FLOOR DEMOLITION PLAN - AREA 'A'
0 4' 8' 16'
PLAN
NORTH
SCALE: 1/8" = 1'-0"
PARTIAL SECOND FLOOR DEMOLITION PLAN - AREA 'B'
GENERAL SHEET NOTES
DEMOLITION KEYNOTES
1 REFER TO OTHER PORTION OF THE CONTRACT DOCUMENTS FOR ADDITIONAL
INFORMATION AND INSTRUCTIONS.
2 EXISTING FAN COIL UNITS TO REMAIN. PROTECT UNITS THROUGHOUT
DEMOLITION AND RENOVATION WORK.
1 EXISTING BRICK VENEER EXTERIOR WALL TO REMAIN.
2 REMOVE EXTERIOR BRICK VENEER WALL COMPLETE. EXISTING INTERIOR
CMU WALL TO REMAIN (FOR BIDDING PURPOSES ASSUME 9,979 SF TOTAL
EXTERIOR BRICK VENEER PER PROJECT).
3 REMOVE PRECAST CONCRETE WINDOW SILL COMPLETE (FOR BIDDING
PURPOSES ASSUME 1,073 LF TOTAL PRECAST CONCRETE WINDOW SILL PER
PROJECT).
4 REMOVE ALUMINUM WINDOW SYSTEM COMPLETE AND SALVAGE FOR
REINSTALLATION. EXISTING STEEL STRUCTURE CONCEALED BY WINDOW
MULLIONS IS EXISTING TO REMAIN (FOR BIDDING PURPOSES ASSUME 7,290
SF TOTAL ALUMINUM WINDOW SYSTEM PER PROJECT).
5 REMOVE CONCRETE CANOPY AND ALL ASSOCIATED COMPONENTS
COMPLETE, INCLUDING TAPERED INSULATION, WOOD BLOCKING, METAL
COUNTERFLASHING, AND METAL GRAVEL STOP (FOR BIDDING PURPOSES
ASSUME 26.98 CY OF CONCRETE, 133 LF OF METAL GRAVEL STOP, 133 LF OF
WOOD BLOCKING, 86 LF OF METAL COUNTERFLASHING, 517 SF OF TAPERED
INSULATION, AND 517 SF OF BALLASTED ROOF GRAVEL TOTAL FOR
CONCRETE CANOPIES PER PROJECT).
6 REMOVE PLASTIC LAMINATE WINDOW SILL CONSTRUCTION COMPLETE.
PREPARE SURFACE FOR INSTALLATION OF NEW WINDOW SILL
CONSTRUCTION (FOR BIDDING PURPOSES, ASSUME 928 LF TOTAL OF
PLASTIC LAMINATE WINDOW SILL PER PROJECT).
7 REMOVE SURFACE MOUNTED ELECTRICAL AND TELECOMMUNICATIONS
WIREWAY AND RECEPTACLES COMPLETE AND SALVAGE FOR
REINSTALLATION. REMOVE AND SALVAGE EXISTING POWER AND DATA
WIRING - SEE ELECTRICAL DRAWINGS.
8 REMOVE EXTERIOR STAIR, RAILING, STEEL SUPPORT COLUMNS, FOOTINGS,
AND ALL ASSOCIATED COMPONENTS COMPLETE (FOR BIDDING PURPOSES
ASSUME 1 STAIR TOTAL PER PROJECT) - SEE STRUCTURAL DRAWINGS.
9 REMOVE PAINT AND PREPARE SURFACE FOR NEW PAINT - SEE SHEETS
HM101 AND A-101.
10 REMOVE CARPET COMPLETE. REMEDIATE EXPOSED ASBESTOS TILE AND
MASTIC - SEE SHEET HM101.
11 REMOVE EXTERIOR BRICK VENEER INFILL WALL.
12 REMOVE EXISTING ROOF ACCESS LADDER COMPLETE.
13 REMOVE DAMAGED AND CRACKED INTERIOR CMU WALL FULL HEIGHT TO
EXTENTS SHOWN TO ALLOW FOR INSTALLATION OF 1" EXPANSION JOINT
(FOR BIDDING PURPOSES, ASSUME 33 SF OF CMU WALL) - SEE STRUCTURAL
DRAWINGS.
14 REMOVE HOLLOW METAL FRAME AND DOOR SYSTEM COMPLETE (FOR
BIDDING PURPOSES ASSUME 5 HOLLOW METAL FRAME AND DOOR SYSTEMS
TOTAL PER PROJECT).
SY
M
DE
S C
RI
PT
I O N
DA
TE
K
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 2423
J
H
G
F
E
D
C
B
A
MA
TC
HL
IN
E -A
RE
A
'A
MA
TC
HL
IN
E -A
RE
A
'B
2 2
2 2
2 2
2 2 2 2 2
1 1
±(8'-6")
±(8'-6")
±(8'-6")
±(8'-6")
±(10'-0")
±(8'-6")
±(10'-0") ±(10'-0")±(10'-0")
±(8'-6")
±(8'-6")
±(8'-6")
5 5
5 5
4'-9" ±
2'- 0"
± 5'-8" ±
2'- 0"
4'-9" ±
2'- 0"
4'-9" ±
2'- 0"
8 9
15 14
±(8'-6") ±(8'-6")
K
20 21 22 2423
25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
J
H
G
F
E
D
C
B
A
MA
TC
HL
IN
E -A
RE
A
'A
MA
TC
HL
IN
E -A
RE
A
'B ' 2 2 2 2 2 2 2
2 2 2 2
2 21
±(8'-6")
±(8'-6")
±(8'-6")
±(8'-6")
±(10'-0") ±(10'-0")
±(10'-0")
±(10'-0")
±(8'-6") ±(8'-6") ±(8'-6")
±(8'-6")
±(8'-6")
±(8'-6")
±(8'-6")
5 5
5 5 5
5 5
4'-9" ±
2'- 0"
± 5'-8" ±
2'- 0"
4'-9" ±
2'- 0"
4'-9" ±
2'- 0"
±(8'-6")
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
DRAWFORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
C O
M M
AN
D
M
ID
-A
TL
AN
TI
C
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
UN
CL
AS
SI
FI
ED
PW
D
N O
R
FO
LK
AD105
B U
IL
D
IN
G
S P
-2
SE
CO
ND
F
LO
O
R
RE
FL
EC
TE
D
CE
IL
IN
G
P
LA
N -D
EM
O
LI
TI
O N
LAB
12,820,997
SAR SAR
02/15/21
MICHAEL COMPTON, CNATTU
EX
TE
RI
O
R
RE
PA
IR
S
RO
O
F
RE
NO
VA
TI
O
N
SEBASTIAN A. RAMOS, R.A.
1576521
N/A
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
TA
TI
ON
S. M. SWEENEY, P.E.
0 4' 8' 16'
PLAN
NORTH
SCALE: 1/8" = 1'-0"
PARTIAL SECOND FLOOR REFLECTED CEILING DEMOLITION PLAN - AREA 'A'
0 4' 8' 16'
PLAN
NORTH
SCALE: 1/8" = 1'-0"
PARTIAL SECOND FLOOR REFLECTED CEILING DEMOLITION PLAN - AREA 'B'
GENERAL SHEET NOTES
DEMOLITION KEYNOTES
1 EXISTING ACOUSTICAL CEILING TILE GRID TO REMAIN.
2 REFER TO OTHER PORTIONS OF THE CONTRACT DOCUMENTS FOR
ADDITIONAL INFORMATION AND INSTRUCTIONS.
1 REMOVE 2' X 2' ACOUSTICAL CEILING TILE AS INDICATED (FOR BIDDING
PURPOSES ASSUME 350 SF TOTAL OF ACT PER PROJECT).
2 REMOVE GWB OVER PLASTER AND ACOUSTICAL PANEL CEILING TO EXTENTS
INDICATED - SEE SHEETS HM101 AND A-101 (FOR BIDDING PURPOSES
ASSUME 834 SF TOTAL GWB CEILING SURFACES PER PROJECT).
3 REMOVE ALUMINUM WINDOW SYSTEM COMPLETE AND SALVAGE FOR
REINSTALLATION. EXISTING STEEL STRUCTURE CONCEALED BY WINDOW
MULLIONS IS EXISTING TO REMAIN (FOR BIDDING PURPOSES ASSUME 7,290
SF TOTAL ALUMINUM WINDOW SYSTEM PER PROJECT).
4 REMOVE EXISTING PAINT AND PREPARE SURFACE FOR NEW PAINT - SEE
SHEETS HM101 AND A-101.
5 REMOVE WINDOW SHADES AND ALL ASSOCIATED COMPONENTS COMPLETE
(FOR BIDDING PURPOSES ASSUME 928 LF TOTAL PER PROJECT).
6 REMOVE TOP 3 CMU COURSES OF INTERIOR CMU WALL COMPLETE IN
PREPARATION FOR REMOVAL OF STEEL JOISTS.
7 REMOVED ABANDONED 6" DIA. PIPE RUN WITHIN ROOM COMPLETE. CAP AT
END THAT LEAVES THE ROOM.
8 CONTRACTOR TO REMOVE PIPING OR DUCTING THAT IS SUPPORTED BY OR
PENETRATING ROOF STRUCTURE THAT IS DETERMINED TO BE ABANDONED.
9 TEMPORARILY SUPPORT ACTIVE EXISTING PIPING, CABLING, OR DUCTING TO
REMAIN THAT IS SUPPORTED BY ROOF STRUCTURE AS REQUIRED DURING
DEMOLITION OF ROOF. PIPING MUST BE RE-SUPPORTED FROM ROOF
STRUCTURE AFTER NEW WORK IS COMPLETE.
10 REMOVE EXHAUST FAN COMPLETE INCLUDING ALL ASSOCIATED DUCTWORK
ON SECOND FLOOR AND DOWN TO FIRST FLOOR (ASSUME 24 X 24
DUCTWORK FOR BIDDING PURPOSES).
11 DISCONNECT AND TEMPORARILY REMOVE PIPING LINES RUNNING THROUGH
JOISTS TO BE REPLACED. PREPARE FOR REINSTALLATION OF LINES AFTER
JOISTS REPLACEMENT HAS BEEN COMPLETED.
12 REMOVE EXHAUST FAN COMPLETE.
13 REMOVE EXISTING PLASTER CEILING ATTACHED TO STEEL JOIST
STRUCTURE COMPLETE. EXISTING SPRINKLER SYSTEM TO REMAIN.
14 REMOVE EXISTING LIGHTING FIXTURES COMPLETE - SEE ELECTRICAL
DRAWINGS.
15 REMOVE EXISTING STEEL JOISTS COMPLETE - SEE STRUCTURAL DRAWINGS.
16 REMOVE AND SALVAGE EXISTING LIGHTING FIXTURES - SEE ELECTRICAL
DRAWINGS.
SY
M
DE
S C
RI
PT
I O N
DA
TE
MA
TC
HL
IN
E -A
RE
A
'A
MA
TC
HL
IN
E -A
RE
A
'B
1 23
3 35
9 4
3 35
9 4 9
3 35 3 35
9 4
EF
EF
PV PV
PV
3 3
11 TYP
4 TYP
1 2
1 2 1 2
6 6
6 12
A1
AD502
A4
AD502
A1
AD502
10" ± 61'-6" ± 35'-6" ± 92'-2" ± 10" ±
'-0
8'- 6"
17'-3" ±
25'-4" ±
6'- 0"
28'-4 1/2" ±
6'- 0"
2'-
6"
3 3
16TYP
SIM
A4
AD502
A4
AD502
A4
AD502
EF
EF
GV GV GV GV
MA
TC
HL
IN
E -A
RE
A
'A
MA
TC
HL
IN
E -A
RE
A
'B
9 5 3
1 2 1 2
3 5
PV PV
4 4 4
3 5 3 5 3
1 2 1 2
6 6
6 12
6 12
6 6
6 6
A1
AD502
A1
AD502
A4
AD502
8'- 6"
10" ± 56'-5" ± 35'-6" ± 56'-5" ± 10" ±
17'-2" ±
6'- 0"
2'-
6"
'-0
6'- 0"
25'-4" ±
A1
AD502
A4
AD502
A4
AD502
A4
AD502
C1
AD503
A1
AD503
EF
EF
GVGVGV
EF
GV
/A1 AD501
/C4 AD501 /B4 AD501
/B2 AD501
/A4 AD501
/B1 AD502
/B4 AD502
/A2 AD501
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
DRAWFORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
C O
M M
AN
D
M
ID
-A
TL
AN
TI
C
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
UN
CL
AS
SI
FI
ED
PW
D
N O
R
FO
LK
AD106
B U
IL
D
IN
G
S P
-2
RO
O
F
PL
AN
DE
M
O
LI
TI
O
N
LAB
12,820,998
SAR SAR
02/15/21
MICHAEL COMPTON, CNATTU
EX
TE
RI
O
R
RE
PA
IR
S
RO
O
F
RE
NO
VA
TI
O
N
SEBASTIAN A. RAMOS, R.A.
1576521
N/A
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
TA
TI
ON
S. M. SWEENEY, P.E.
0 4' 8' 16'
PLAN
NORTH
SCALE: 1/8" = 1'-0"
PARTIAL ROOF DEMOLITION PLAN - AREA 'A'
0 4' 8' 16'
PLAN
NORTH
SCALE: 1/8" = 1'-0"
PARTIAL ROOF DEMOLITION PLAN - AREA 'B'
GENERAL SHEET NOTES CONT.
DEMOLITION KEYNOTES
6 THE EXISTING ROOF VENT PIPE PENETRATIONS ACTUAL DIAMETERS VARY.
ASSUME 4” DIAMETER FOR PROJECT.
7 THE EXISTING EXHAUST FANS AND TOWER VENTILATORS ACTUAL
DIMENSIONS VARY. ASSUME 3’-6” SQUARE FOR PROJECT.
8 ALL EXISTING RAINLEADER PIPING MUST REMAIN.
9 THE EXISTING MECHANICAL EQUIPMENT ALONG WITH ITS ASSOCIATED
DUCTWORK, PIPING, ELECTRICAL CONDUIT AND STRUCTURAL STEEL
SUPPORT FRAMING, MUST REMAIN IN PLACE DURING CONSTRUCTION.
1 REFER TO OTHER PORTION OF THE CONTRACT DOCUMENTS FOR
ADDITIONAL INFORMATION AND INSTRUCTIONS.
2 THE CONTRACTOR MUST MAINTAIN THE WATERTIGHT INTEGRITY OF THE
ROOF AT ALL TIMES.
3 THE EXISTING ROOF STRUCTURE CONSISTS OF A 1 1/2” METAL DECK ON
STEEL JOISTS.
4 ALL EXISTING ROOF DRAINS ARE ASSUMED TO BE 4” DIAMETER.
5 THE EXISTING ROOF VENT PIPE PENETRATIONS ACTUAL HEIGHT VARIES.
ASSUME 1’-6” ABOVE EXISTING DECK FOR PROJECT HEIGHT.
1 REMOVE ALL LOOSE BALLASTED ROOF GRAVEL COMPLETE (FOR BIDDING
PURPOSES ASSUME 14,213 SF TOTAL BALLASTED GRAVEL PER PROJECT).
2 REMOVE BUILT-UP ROOFING SYSTEM AND ALL ASSOCIATED COMPONENTS
COMPLETE (FOR BIDDING PURPOSES ASSUME 14,213 SF TOTAL BUILT-UP
ROOFING SYSTEM PER PROJECT).
3 REMOVE BUILT-UP ROOF CRICKETS COMPLETE.
4 REMOVE WALK-WAY PADS COMPLETE.
5 REMOVE ROOF DRAIN DOME COMPLETE. EXISTING ROOF DRAIN AND RAIN
LEADER SYSTEM CONSTRUCTION TO REMAIN -
SEE DETAIL (FOR BIDDING PURPOSES ASSUME 9 ROOF DRAIN
DOMES TOTAL PER PROJECT).
6 REMOVE METAL GRAVEL STOP CONSTRUCTION COMPLETE (FOR BIDDING
PURPOSES ASSUME 655 LF TOTAL METAL GRAVEL STOP PER PROJECT).
7 REMOVE PARAPET COPING CONSTRUCTION COMPLETE (FOR BIDDING
PURPOSES ASSUME 143 LF TOTAL OF PARAPET COPING PER PROJECT).
8 EXHAUST FANS TO REMAIN.
9 REMOVE GRAVITY VENTILATOR COMPLETE. ROOF CURB TO REMAIN.
PREPARE CURB FOR INSTALLATION OF NEW GRAVITY VENTILATOR TO
MATCH EXISTING - SEE DETAIL (FOR BIDDING PURPOSES
ASSUME 8 GRAVITY VENTILATORS TOTAL PER PROJECT).
10 MECHANICAL ROOFTOP UNIT TO REMAIN.
11 MECHANICAL ROOFTOP UNIT SUPPORT STEEL STRUCTURE TO REMAIN - SEE
STRUCTURAL DRAWINGS.
12 REMOVE MECHANICAL UNIT CONDENSATION PIPING LINE COMPLETE (FOR
BIDDING PURPOSES ASSUME 55 LF TOTAL OF PIPE PER PROJECT).
13 REMOVE ROOFTOP HATCH AND CURB COMPLETE -
SEE DETAIL (FOR BIDDING PURPOSES ASSUME 1 ROOFTOP
HATCH TOTAL PER PROJECT).
14 REMOVE ROOF EXPANSION JOINT CLOSURE MEMBRANE CONSTRUCTION
COMPLETE (FOR BIDDING PURPOSES ASSUME 32 LF OF ROOF EXPANSION
JOINT TOTAL PER PROJECT).
15 PIPE VENTS TO REMAIN. REMOVE ADJACENT PIPE VENT ROOF AND
FLASHING CONSTRUCTION - SEE DETAILS & .
16 ROOF PENETRATION COVER TO REMAIN. REMOVE ADJACENT PIPE VENT
ROOF AND FLASHING CONSTRUCTION - SEE DETAIL .
17 REMOVE STEEL STRUCTURE PENETRATION METAL COVER AND ADJACENT
CURB - SEE DETAIL .
18 REMOVE EXHAUST FAN COMPLETE INCLUDING ALL ASSOCIATED DUCTWORK
ON SECOND FLOOR AND DOWN TO FIRST FLOOR - SEE DETAIL
(ASSUME 24 x 24 DUCTWORK FOR BIDDING PURPOSES).
GENERAL SHEET NOTES
SY
M
DE
S C
RI
PT
I O N
DA
TE
FIRST FLOOR
0"
SECOND FLOOR
12'-8"
T.O.J.
24'-6"
9'-1 1/2" ±17'-2 1/4" ±9'-1 1/2" ±
211910 3 8 TYP 9
3 9 3 11 8 TYP 10
15 2
6148 TYP11311416112017324118 TYP14
AD203
A2
1'-7 1/8" ± 55'-8 1/4" ± 35'-5 1/4" ± 55'-8 1/4" ± 1'-7 1/8" ± 31'-5 5/8" ±
3 3
TYP
A4
AD301
FIRST FLOOR
0"
SECOND FLOOR
12'-8"
T.O.J.
24'-6"
1'-7 1/8" ±60'-9" ±35'-3 1/4" ±60'-11" ±
9'-1 1/2" ±17'-2 1/4" ±8'-11 1/2" ±
211 9 103 8 TYP 93 11 8 TYP17
4 1411
11 9 3 1
218 TYP11 3 3 11
3 3
23232323
24 24
TYP
2 11
A2
AD301
A3
AD301
308 TYP
FIRST FLOOR
0"
SECOND FLOOR
12'-8"
T.O.J.
24'-6"
7 7 7
12 14
1 13
42'-2" ±
/A4 AD501
/A2 AD501
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
DRAWFORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
C O
M M
AN
D
M
ID
-A
TL
AN
TI
C
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
UN
CL
AS
SI
FI
ED
PW
D
N O
R
FO
LK
AD201
B U
IL
D
IN
G
S P
-2
NO
RT
H
AN
D
EA
ST
E
XT
ER
IO
R
EL
EV
AT
IO
NS
DE
M
O
LI
TI
O
N
LAB
12,820,999
SAR SAR
02/15/21
MICHAEL COMPTON, CNATTU
EX
TE
RI
O
R
RE
PA
IR
S
RO
O
F
RE
NO
VA
TI
O
N
SEBASTIAN A. RAMOS, R.A.
1576521
N/A
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
TA
TI
ON
S. M. SWEENEY, P.E.
0 4' 8' 16'SCALE: 1/8" = 1'-0" (AD101)
PARTIAL EXTERIOR NORTH ELEVATION - DEMOLITIONC1
0 9" 1'-6" 3'SCALE: 1/8" = 1'-0" (AD101)
PARTIAL EXTERIOR NORTH ELEVATION - DEMOLITIONB1
0 4' 8' 16'SCALE: 1/8" = 1'-0" (AD101)
EXTERIOR EAST ELEVATION - DEMOLITIONA1
20 HVAC UNIT TO REMAIN. PROTECT UNIT THROUGHOUT DURATION OF
CONSTRUCTION. DISCONNECT AND RECONNECT UNIT AS REQUIRED TO
COMPLETE RENOVATION WORK – SEE ELECTRICAL DRAWINGS. COORDINATE
WORK WITH COMMAND.
21 REMOVE ELECTRICAL CONDUIT – SEE ELECTRICAL DRAWINGS.
22 REMOVE METAL COVERS COMPLETE.
23 REMOVE GRAVITY VENTILATOR COMPLETE. ROOF CURB TO REMAIN.
PREPARE CURB FOR INSTALLATION OF NEW GRAVITY VENTILATOR TO
MATCH EXISTING - SEE DETAIL (FOR BIDDING PURPOSES
ASSUME 8 GRAVITY VENTILATORS TOTAL PER PROJECT).
24 REMOVE CONDENSATION PVC PIPES FOR THRU-WALL HVAC UNITS FROM
GROUND LEVEL TO EXISTING BRICK VENEER WALL COMPLETE. PREPARE
EXISTING PVC PIPE CONNECTIONS FOR INSTALLATION OF NEW METAL PIPE.
25 CABLE PENETRATION TO REMAIN. PROTECT THROUGHOUT DURATION OF
RENOIVATION WORK.
26 REMOVE EXTERIOR STAIR, RAILING, STEEL SUPPORT COLUMNS, FOOTINGS,
AND ALL ASSOCIATED COMPONENTS COMPLETE (FOR BIDDING PURPOSES
ASSUME 1 STAIR TOTAL PER PROJECT) - SEE STRUCTURAL DRAWINGS.
27 REMOVE CONCRETE PAD COMPLETE.
28 EXHAUST FANS TO REMAIN.
29 MECHANICAL ROOFTOP UNIT TO REMAIN.
30 REMOVE EXTERIOR WINDOW MULLION COVER PANELS COMPLETE (FOR
BIDDING PURPOSES, ASSUME 192 EXTERIOR WINDOW MULLION COVER
PANELS TOTAL PER PROJECT).
31 REMOVE EXHAUST FAN COMPLETE INCLUDING ALL ASSOCIATED DUCTWORK
ON SECOND FLOOR AND DOWN TO FIRST FLOOR - SEE DETAIL
(ASSUME 24 x 24 DUCTWORK FOR BIDDING PURPOSES).
32 EXISTING WALL MOUNTED LIGHTING FIXTURE TO REMAIN.
6 REMOVE HOLLOW METAL FRAME AND DOOR SYSTEM COMPLETE (FOR
BIDDING PURPOSES ASSUME 5 HOLLOW METAL FRAME AND DOOR SYSTEMS
TOTAL PER PROJECT).
7 REMOVE METAL LOUVER COMPLETE. PREPARE OPENING FOR EXTERIOR
WALL BRICK VENEER AND INTERIOR CMU INFILL (FOR BIDDING PURPOSES
ASSUME 7 METAL LOUVERS TOTAL PER PROJECT).
8 REMOVE OUTSIDE AIR INTAKE LOUVER AND COVER COMPLETE. PREPARE
OPENING FOR INSTALLATION OF NEW LOUVER. EXISTING WALL THROUGH
LOUVER DUCT TO REMAIN (FOR BIDDING PURPOSES ASSUME 46 AIR INTAKE
LOUVERS TOTAL PER PROJECT).
9 REMOVE METAL GRAVEL STOP CONSTRUCTION COMPLETE (FOR BIDDING
PURPOSES ASSUME 655 LF TOTAL METAL GRAVEL STOP PER PROJECT).
10 REMOVE PARAPET COPING CONSTRUCTION COMPLETE (FOR BIDDING
PURPOSES ASSUME 143 LF TOTAL OF PARAPET COPING PER PROJECT).
11 REMOVE PRECAST CONCRETE WINDOW SILL COMPLETE (FOR BIDDING
PURPOSES ASSUME 1,073 LF TOTAL PRECAST CONCRETE WINDOW SILL PER
PROJECT).
12 EXTERIOR DOOR TO REMAIN.
13 EXTERIOR METAL STAIR AND ASSOCIATED ELEMENTS TO REMAIN.
14 CONCRETE PAD TO REMAIN - SEE STRUCTURAL DRAWINGS.
15 REMOVE ROOFTOP HVAC UNIT CONDENSATION PVC LINE COMPLETE.
16 REMOVE BUILDING SIGN AND SALVAGE FOR REINSTALLATION.
17 CONDENSATION PVC PIPES FOR THRU-WALL HVAC UNITS TO REMAIN.
PREPARE PVC LINE FOR INSTALLATION OF DOWNSPOUT NOZZLE.
18 GROUNDING CABLE TO REMAIN – SEE ELECTRICAL DRAWINGS.
19 REMOVE BUILDING SIGN. PREPARE SURFACE FOR INSTALLATION OF NEW
BUILDING SIGN.
1 EXISTING EXTERIOR BRICK VENEER TO REMAIN.
2 REMOVE EXTERIOR BRICK VENEER WALL COMPLETE. EXISTING INTERIOR
CMU WALL TO REMAIN (FOR BIDDING PURPOSES ASSUME 9,979 SF TOTAL
EXTERIOR BRICK VENEER PER PROJECT).
3 REMOVE ALUMINUM WINDOW SYSTEM COMPLETE AND SALVAGE FOR
REINSTALLATION. EXISTING STEEL STRUCTURE CONCEALED BY WINDOW
MULLIONS IS EXISTING TO REMAIN (FOR BIDDING PURPOSES ASSUME 7,290
SF TOTAL ALUMINUM WINDOW SYSTEM PER PROJECT).
4 REMOVE ALUMINUM STOREFRONT ENTRY SYSTEM COMPLETE AND SALVAGE
FOR REINSTALLATION (FOR BIDDING PURPOSES ASSUME 432 SF TOTAL
ALUMINUM STOREFRONT ENTRY SYSTEM PER PROJECT).
5 REMOVE CONCRETE CANOPY AND ALL ASSOCIATED COMPONENTS
COMPLETE, INCLUDING TAPERED INSULATION, WOOD BLOCKING, METAL
COUNTERFLASHING, AND METAL GRAVEL STOP (FOR BIDDING PURPOSES
ASSUME 26.98 CY OF CONCRETE, 133 LF OF METAL GRAVEL STOP, 133 LF OF
WOOD BLOCKING, 86 LF OF METAL COUNTERFLASHING, 517 SF OF TAPERED
INSULATION, AND 517 SF OF BALLASTED ROOF GRAVEL TOTAL FOR
CONCRETE CANOPIES PER PROJECT).
DEMOLITION KEYNOTESGENERAL SHEET NOTES
1 REFER TO HAZARDOUS MATERIALS, STRUCTURAL, CIVIL, ELECTRICAL, AND
FIRE PROTECTION DRAWINGS FOR ADDITIONAL INFORMATION AND
INSTRUCTIONS.
2 ALL ELEVATION VIEW TITLES REFER TO PLAN NORTH ORIENTATION.
DEMOLITION KEYNOTES
SY
M
DE
S C
RI
PT
I O N
DA
TE
SECOND FLOOR
12'-8"
T.O.J.
24'-6"
A1
AD301
11910 3 8 TYP 9 3 11 8 TYP
15 8 TYP113423118 TYP14
1'-7 1/8" ± 65'-9 3/4" ± 25'-4" ± 67'-1 1/8" ± 30'-1" ±
AD203
B2
2 2
22 22 2223
A2
AD302
FIRST FLOOR
0"
SECOND FLOOR
12'-8"
T.O.J.
24'-6"
211 9 103 8 TYP 9 118 TYP
9 3 1
8 TYP11 3 3 11
8 TYP
1'-7 1/8" ±60'-9" ±25'-3 3/4" ±62'-5 1/8" ±
21212
2 146
22 22 22
FIRST FLOOR
0"
SECOND FLOOR
12'-8"
T.O.J.
24'-6"
7 7 7
27 12 27
7 10
1'-5 3/4" 7'-4 5/8" 42'-2"
A1
AD302
/A4 AD501
/A2 AD501
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
DRAWFORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
C O
M M
AN
D
M
ID
-A
TL
AN
TI
C
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
UN
CL
AS
SI
FI
ED
PW
D
N O
R
FO
LK
AD202
B U
IL
D
IN
G
S P
-2
SO
UT
H
AN
D W
ES
T
EX
TE
RI
O
R
EL
EV
AT
IO
NS
DE
M O
LI
TI
O N
LAB
12,821,000
SAR SAR
02/15/21
MICHAEL COMPTON, CNATTU
EX
TE
RI
O
R
RE
PA
IR
S
RO
O
F
RE
NO
VA
TI
O
N
SEBASTIAN A. RAMOS, R.A.
1576521
N/A
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
TA
TI
ON
S. M. SWEENEY, P.E.
0 4' 8' 16'SCALE: 1/8" = 1'-0" (AD101)
PARTIAL EXTERIOR SOUTH ELEVATION - DEMOLITIONC1
0 9" 1'-6" 3'SCALE: 1/8" = 1'-0" (AD101)
PARTIAL EXTERIOR SOUTH ELEVATION - DEMOLITIONB1
0 4' 8' 16'SCALE: 1/8" = 1'-0" (AD101)
EXTERIOR WEST ELEVATION - DEMOLITIONA1
DEMOLITION KEYNOTESGENERAL SHEET NOTES
1 REFER TO HAZARDOUS MATERIALS, STRUCTURAL, CIVIL, ELECTRICAL, AND
FIRE PROTECTION DRAWINGS FOR ADDITIONAL INFORMATION AND
INSTRUCTIONS.
2 ALL ELEVATION VIEW TITLES REFER TO PLAN NORTH ORIENTATION.
21 REMOVE CONDENSATION PVC PIPES FOR THRU-WALL HVAC UNITS FROM
GROUND LEVEL TO EXISTING BRICK VENEER WALL COMPLETE. PREPARE
EXISTING PVC PIPE CONNECTIONS FOR INSTALLATION OF NEW METAL PIPE.
22 REMOVE GRAVITY VENTILATOR COMPLETE. ROOF CURB TO REMAIN.
PREPARE CURB FOR INSTALLATION OF NEW GRAVITY VENTILATOR TO
MATCH EXISTING - SEE DETAIL (FOR BIDDING PURPOSES
ASSUME 8 GRAVITY VENTILATORS TOTAL PER PROJECT).
23 EXISTING EXHAUST FANS TO REMAIN.
24 EXISTING MECHANICAL ROOFTOP UNIT TO REMAIN.
25 REMOVE EXTERIOR WINDOW MULLION COVER PANELS COMPLETE (FOR
BIDDING PURPOSES, ASSUME 192 EXTERIOR WINDOW MULLION COVER
PANELS TOTAL PER PROJECT).
26 REMOVE EXHAUST FAN COMPLETE INCLUDING ALL ASSOCIATED DUCTWORK
ON SECOND FLOOR AND DOWN TO FIRST FLOOR - SEE DETAIL
(ASSUME 24 x 24 DUCTWORK FOR BIDDING PURPOSES).
27 REMOVE ABANDONED OVERHEAD DOORS COMPLETE. TOOTH-OUT AND
REMOVE EXISTING CUT BRICK AT OPENING PERIMETER (FOR BIDDING
PURPOSES ASSUME 2 TOTAL ABANDONED OVERHEAD DOORS PER
PROJECT).
28 REMOVE WALL MOUNTED LIGHTING FIXTURE - SEE ELECTRICAL DRAWINGS
(FOR BIDDING PURPOSES ASSUME 1 WALL MOUNTED LIGHTING FIXTURE
TOTAL PER PROJECT).
7 REMOVE METAL LOUVER AND OPENING SUPPORT STEEL ANGLES
COMPLETE. PREPARE OPENING FOR EXTERIOR WALL BRICK VENEER AND
INTERIOR CMU INFILL (FOR BIDDING PURPOSES ASSUME 7 METAL LOUVERS
TOTAL PER PROJECT).
8 REMOVE OUTSIDE AIR INTAKE LOUVER COMPLETE AND SALVAGE FOR
REINSTALLATION. EXISTING THRU-WALL LOUVER DUCT TO REMAIN (FOR
BIDDING PURPOSES ASSUME 58 AIR INTAKE LOUVERS TOTAL PER PROJECT).
9 REMOVE METAL GRAVEL STOP CONSTRUCTION COMPLETE (FOR BIDDING
PURPOSES ASSUME 655 LF TOTAL METAL GRAVEL STOP PER PROJECT).
10 REMOVE PARAPET COPING CONSTRUCTION COMPLETE (FOR BIDDING
PURPOSES ASSUME 143 LF TOTAL OF PARAPET COPING PER PROJECT).
11 REMOVE PRECAST CONCRETE WINDOW SILL COMPLETE (FOR BIDDING
PURPOSES ASSUME 1,073 LF TOTAL PRECAST CONCRETE WINDOW SILL PER
PROJECT).
12 REMOVE HOLLOW METAL FRAME AND DOOR SYSTEM COMPLETE (FOR
BIDDING PURPOSES ASSUME 3 HOLLOW METAL FRAME AND DOOR SYSTEMS
TOTAL PER PROJECT).
13 EXTERIOR METAL STAIR AND ASSOCIATED ELEMENTS TO REMAIN.
14 CONCRETE PAD TO REMAIN.
15 ELECTRICAL CONDUIT TO REMAIN – SEE ELECTRICAL DRAWINGS.
16 REMOVE AND SALVAGE BUILDING SIGN AND SALVAGE FOR REINSTALLATION.
17 REMOVE BUILDING SIGN. PREPARE SURFACE FOR INSTALLATION OF NEW
BUILDING SIGN.
18 GROUNDING CABLE TO REMAIN – SEE ELECTRICAL DRAWINGS.
19 REMOVE EXTERIOR STAIR, RAILING, STEEL SUPPORT COLUMNS, FOOTINGS,
AND ALL ASSOCIATED COMPONENTS COMPLETE.
20 CONDENSATION PVC PIPES FOR THRU-WALL HVAC UNITS TO REMAIN.
PREPARE PVC LINE FOR INSTALLATION OF DOWNSPOUT NOZZLE.
1 EXISTING BRICK VENEER EXTERIOR WALL TO REMAIN.
2 REMOVE EXTERIOR BRICK VENEER WALL COMPLETE. EXISTING INTERIOR
CMU WALL TO REMAIN (FOR BIDDING PURPOSES ASSUME 9,979 SF TOTAL
EXTERIOR BRICK VENEER PER PROJECT).
3 REMOVE ALUMINUM WINDOW SYSTEM COMPLETE AND SALVAGE FOR
REINSTALLATION. EXISTING STEEL STRUCTURE CONCEALED BY WINDOW
MULLIONS IS EXISTING TO REMAIN (FOR BIDDING PURPOSES ASSUME 7,290
SF TOTAL ALUMINUM WINDOW SYSTEM PER PROJECT).
4 REMOVE ALUMINUM STOREFRONT ENTRY SYSTEM COMPLETE AND SALVAGE
FOR REINSTALLATION (FOR BIDDING PURPOSES ASSUME 432 SF TOTAL
ALUMINUM STOREFRONT ENTRY SYSTEM PER PROJECT).
5 REMOVE CONCRETE CANOPY AND ALL ASSOCIATED COMPONENTS
COMPLETE, INCLUDING TAPERED INSULATION, WOOD BLOCKING, METAL
COUNTERFLASHING, AND METAL GRAVEL STOP (FOR BIDDING PURPOSES
ASSUME 26.98 CY OF CONCRETE, 133 LF OF METAL GRAVEL STOP, 133 LF OF
WOOD BLOCKING, 86 LF OF METAL COUNTERFLASHING, 517 SF OF TAPERED
INSULATION, AND 517 SF OF BALLASTED ROOF GRAVEL TOTAL FOR
CONCRETE CANOPIES PER PROJECT).
6 REMOVE CONCRETE PAD COMPLETE - SEE STRUCTURAL DRAWINGS.
DEMOLITION KEYNOTES
SY
M
DE
S C
RI
PT
I O N
DA
TE
SECOND FLOOR
12'-8"
T.O.J.
24'-6"
1'-6 1/2" ±
FIRST FLOOR
0"
SECOND FLOOR
12'-8"
T.O.J.
24'-6"
1'-7" ±
1 ±
FIRST FLOOR
0"
SECOND FLOOR
12'-8"
T.O.J.
24'-6"
1'-7" ±
FIRST FLOOR
0"
SECOND FLOOR
12'-8"
T.O.J.
24'-6"
3'-0" ±
FIRST FLOOR
0"
SECOND FLOOR
12'-8"
T.O.J.
24'-6"
8'-11" ±
FIRST FLOOR
0"
SECOND FLOOR
12'-8"
T.O.J.
24'-6"
3'-0" ±
FIRST FLOOR
0"
SECOND FLOOR
12'-8"
T.O.J.
24'-6"
8'-6 1/2" ±
FIRST FLOOR
0"
SECOND FLOOR
12'-8"
T.O.J.
24'-6"
3'-1" ±
FIRST FLOOR
0"
SECOND FLOOR
12'-8"
T.O.J.
24'-6"
3'-1" ±
FIRST FLOOR
0"
SECOND FLOOR
12'-8"
T.O.J.
24'-6"
1'-6 1/2" ±
FIRST FLOOR
0"
SECOND FLOOR
12'-8"
T.O.J.
24'-6"
1'-8" ±
FIRST FLOOR
0"
FIRST FLOOR
0"
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
DRAWFORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
C O
M M
AN
D
M
ID
-A
TL
AN
TI
C
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
UN
CL
AS
SI
FI
ED
PW
D
N O
R
FO
LK
AD203
B U
IL
D
IN
G
S P
-2
EX
TE
RI
O
R
EL
EV
AT
IO
NS
DE
M O
LI
TI
O N
LAB
12,821,001
SAR SAR
02/15/21
MICHAEL COMPTON, CNATTU
EX
TE
RI
O
R
RE
PA
IR
S
RO
O
F
RE
NO
VA
TI
O
N
SEBASTIAN A. RAMOS, R.A.
1576521
N/A
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
TA
TI
ON
S. M. SWEENEY, P.E.
0 4' 8' 16'SCALE: 1/8" = 1'-0" (AD101)
EXT. ELEVATION - DEMO.D2 0 4' 8' 16'SCALE: 1/8" = 1'-0" (AD101)
EXT. ELEVATION - DEMO.D4 0 4' 8' 16'SCALE: 1/8" = 1'-0" (AD101)
EXT. ELEVATION - DEMO.D5
0 4' 8' 16'SCALE: 1/8" = 1'-0" (AD101)
EXT. ELEVATION - DEMO.C1
0 4' 8' 16'SCALE: 1/8" = 1'-0" (AD101)
EXT. ELEVATION - DEMO.D3
0 4' 8' 16'SCALE: 1/8" = 1'-0" (AD101)
EXT. ELEVATION - DEMO.C2 0 4' 8' 16'SCALE: 1/8" = 1'-0" (AD101)
EXT. ELEVATION - DEMO.C3 0 4' 8' 16'SCALE: 1/8" = 1'-0" (AD101)
EXT. ELEVATION - DEMO.C4 0 4' 8' 16'SCALE: 1/8" = 1'-0" (AD101)
EXT. ELEVATION - DEMO.C5
0 4' 8' 16'SCALE: 1/8" = 1'-0" (AD101)
EXT. ELEVATION - DEMO.D1
0 4' 8' 16'SCALE: 1/8" = 1'-0" (AD101)
EXT. ELEVATION - DEMO.B1 0 2' 4' 8'SCALE: 1/4" = 1'-0" (AD202)
ENLARGED EXTERIOR ELEVATION - DEMOLITIONB2
0 2' 4' 8'SCALE: 1/4" = 1'-0" (AD201)
ENLARGED EXTERIOR ELEVATION - DEMOLITIONA2
DEMOLITION KEYNOTES CONT.GENERAL SHEET NOTES
DEMOLITION KEYNOTES
14 HOSE BIB TO REMAIN. PROTECT UNIT THROUGHOUT DURATION OF
CONSTRUCTION WORK.
15 REMOVE EXISTING SPRINKLER ALARM COMPLETE AND SALVAGE FOR
REINSTALLATION.
16 REMOVE EXISTING EXHAUST PIPE CAPS COMPLETE AND SALVAGE FOR
REINSTALLATION. EXISTING PIPE THRU WALL PENETRATIONS TO REMAIN.
PROTECT UNITS THROUGHOUT DURATION OF CONSTRUCTION.
17 REMOVE EXISTING WALL MOUNTED HVAC UNIT AND SALVAGE FOR
REINSTALLATION. COORDINATE WORK WITH COMMAND - SEE ELECTRICAL
DRAWINGS.
18 REMOVE EXISTING WALL MOUNTED HVAC UNIT DISCONNECT SWITCH AND
SALVAGE FOR REINSTALLATION. COORDINATE WORK WITH COMMAND - SEE
ELECTRICAL DRAWINGS.
19 REMOVE ABANDONED CONDUITS AND JUNCTION BOX COMPLETE - SEE
ELECTRICAL DRAWINGS.
20 REMOVE ELECTRICAL METER AND SALVAGE FOR REINSTALLATION.
COORDINATE WORK WITH COMMAND - SEE ELECTRICAL DRAWINGS.
21 REMOVE EXISTING HVAC UNIT REFRIGERANT LINE AND SLEEVE AND
SALVAGE FOR REINSTALLATION. COORDINATE WORK WITH COMMAND.
22 REMOVE EXISTING ANTENNA AND ASSOCIATED ELEMENTS AND SALVAGE
FOR REINSTALLATION. COORDINATE WORK WITH COMMAND - SEE
ELECTRICAL DRAWINGS.
23 REMOVE CONDENSATION PVC PIPES FOR EXISTING WALL THRU-WALL UNITS
FROM GROUND LEVEL TO EXISTING BRICK VENEER WALL COMPLETE.
PREPARE EXISTING PVC PIPE CONNECTIONS FOR INSTALLATION OF NEW
METAL PIPE.
24 HVAC UNIT TO REMAIN. PROTECT UNIT THROUGHOUT DURATION OF
CONSTRUCTION. DISCONNECT AND RECONNECT UNIT AS REQUIRED TO
COMPLETE RENOVATION WORK - SEE ELECTRICAL DRAWINGS. COORDINATE
HVAC DISCONNECTIONS AND RECONNECTIONS WITH COMMAND.
25 REMOVE EXISTING CONCRETE PAD COMPLETE.
1 EXISTING BRICK VENEER EXTERIOR WALL TO REMAIN.
2 REMOVE EXTERIOR BRICK VENEER WALL COMPLETE. EXISTING INTERIOR
CMU WALL TO REMAIN (FOR BIDDING PURPOSES ASSUME 9,979 SF TOTAL
EXTERIOR BRICK VENEER PER PROJECT).
3 REMOVE METAL LOUVER COMPLETE. PREPARE OPENING FOR INSTALLATION
OF NEW METAL LOUVER (FOR BIDDING PURPOSES ASSUME 7 METAL
LOUVERS TOTAL PER PROJECT).
4 REMOVE METAL GRAVEL STOP CONSTRUCTION COMPLETE (FOR BIDDING
PURPOSES ASSUME 655 LF TOTAL METAL GRAVEL STOP PER PROJECT).
5 REMOVE HOLLOW METAL FRAME AND DOOR SYSTEM AND SALVAGE FOR
REINSTALLATION (FOR BIDDING PURPOSES ASSUME 2 HOLLOW METAL
FRAME AND DOOR SYSTEMS TOTAL PER PROJECT).
6 REMOVE EXISTING CONCRETE CANOPY AND ALL ASSOCIATED COMPONENTS
COMPLETE, INCLUDING TAPERED INSULATION, WOOD BLOCKING, METAL
COUNTERFLASHING, AND METAL GRAVEL STOP.
7 EXISTING CONCRETE PAD TO REMAIN.
8 REMOVE EXTERIOR STAIR, RAILING, STEEL SUPPORT COLUMNS, FOOTINGS,
AND ALL ASSOCIATED COMPONENTS COMPLETE (FOR BIDDING PURPOSES
ASSUME 1 STAIR TOTAL PER PROJECT).
9 EXISTING EXTERIOR METAL STAIR AND ASSOCIATED ELEMENTS TO REMAIN.
10 REMOVE EXISTING STANDPIPE CONNECTION CAP AND SALVAGE FOR
REINSTALLATION. PROTECT UNITS THROUGHOUT DURATION OF
CONSTRUCTION.
11 EXISTING NATURAL GAS METER TO REMAIN. PROTECT UNIT THROUGHOUT
DURATION OF CONSTRUCTION WORK. DISCONNECT AND RECONNECT UNIT
AS REQUIRED TO COMPLETE RENOVATION WORK. COORDINATE UTILITY
DISCONNECTIONS AND RECONNECTIONS WITH COMMAND.
12 EXISTING SURFACE MOUNTED JUNCTION BOX TO REMAIN - SEE ELECTRICAL
DRAWINGS.
13 DISCHARGE PIPE SPOUTS AND WALL PENETRATIONS TO REMAIN. PROTECT
UNIT THROUGHOUT DURATION OF CONSTRUCTION WORK.
1 REFER TO HAZARDOUS MATERIALS, STRUCTURAL, CIVIL, ELECTRICAL, AND
FIRE PROTECTION DRAWINGS FOR ADDITIONAL INFORMATION AND
INSTRUCTIONS.
SY
M
DE
S C
RI
PT
I O N
DA
TE
SECOND FLOOR
12'-8"
T.O.J.
24'-6"
K
EXISTING CONCRETE
FOUNDATION TO REMAIN
REMOVE EXTERIOR BRICK
VENEER
REMOVE MASONRY TIE
REMOVE PRECAST CONCRETE
WINDOW SILL
INTERIOR CMU WALL TO REMAIN
REMOVE ALUMINUM WINDOW
SYSTEM COMPLETE AND SALVAGE
FOR REINSTALLATION
REMOVE AND SALVAGE OR REMOVE AND
DEMOLISH OUTSIDE AIR INTAKE LOUVER
COMPLETE - SEE SHEETS AD201 & AD202
LOUVER DUCT TO REMAIN
REMOVE PLASTIC LAMINATE
WINDOW SILL CONSTRUCTION
COMPLETE
REMOVE SURFACE MOUNTED
RACEWAY
CUT BACK AND REMOVE EXISTING CEILING AS
REQUIRED FOR REINSTALLATION OF WINDOW
SYSTEM AND INSTALLATION OF STEEL
STRUCTURE
REMOVE STEEL SHELF ANGLE - SEE
STRUCTURAL DRAWINGS
FLOOR SLAB AND ASSOCIATED
STRUCTURAL ELEMENTS TO
REMAIN - SEE STRUCTURAL
DRAWINGS
REMOVE ALL LOOSE BALLASTED
ROOF GRAVEL COMPLETE
REMOVE ROOF CONSTRUCTION
COMPLETE
ROOF STRUCTURE TO REMAIN - SEE
STRUCTURAL DRAWINGS
REMOVE GRAVEL STOP AND
ASSOCIATED CONSTRUCTION
COMPLETE
8 B
RI
CK
S
1'-
B
RI
CK
S
7'- 4"
B
RI
CK
S
5'- 4"
B
RI
CK
S
7'- 4"
B
RI
CK
S
3'- 4"
B
RI
CK
S
2'- 8"
3 B R I
CK
S
8"
B
RI
CK
S
2'- 8"
B
RI
CK
S
2'- 8"
REMOVE INTERIOR CMU WALL AS
REQUIRED FOR INSTALLATION OF
STEEL STRUCTURE
CUT BACK AND REMOVE EXISTING CEILING
AS REQUIRED FOR REINSTALLATION OF
WINDOW SYSTEM AND INSTALLATION OF
STEEL STRUCTURE
REMOVE MASONRY TIES
REMOVE AND SALVAGE OR REMOVE AND
DEMOLISH OUTSIDE AIR INTAKE LOUVER
COMPLETE - SEE SHEETS AD201 & AD202
FIRST FLOOR
0"
SECOND FLOOR
12'-8"
T.O.J.
24'-6"
C
EXISTING CONCRETE
FOUNDATION TO
REMAIN
REMOVE ALUMINUM WINDOW SYSTEM
COMPLETE AND SALVAGE FOR REINSTALLATION
REMOVE PLASTIC LAMINATE WINDOW
SILL CONSTRUCTION COMPLETE
REMOVE SURFACE MOUNTED RACEWAY
REMOVE STEEL SHELF
ANGLE - SEE
STRUCTURAL
DRAWINGS
FLOOR SLAB AND ASSOCIATED STRUCTURAL
ELEMENTS TO REMAIN - SEE STRUCTURAL
DRAWINGS
REMOVE ALL LOOSE BALLASTED ROOF
GRAVEL COMPLETE
REMOVE ROOF CONSTRUCTION COMPLETE
ROOF STRUCTURE TO REMAIN - SEE STRUCTURAL
DRAWINGS
REMOVE GRAVEL STOP AND ASSOCIATED
CONSTRUCTION COMPLETE
REMOVE INTERIOR CMU WALL AS REQUIRED
FOR INSTALLATION OF STEEL STRUCTURE
CUT BACK AND REMOVE EXISTING CEILING AS
REQUIRED FOR REINSTALLATION OF WINDOW
SYSTEM AND INSTALLATION OF STEEL STRUCTURE
REMOVE ALUMINUM
STOREFRONT ENTRY
SYSTEM COMPLETE
AND SALVAGE FOR
REINSTALLATION
REMOVE CONCRETE CANOPY
AND ALL ASSOCIATED
COMPONENTS COMPLETE,
INCLUDING TAPERED
INSULATION, WOOD
BLOCKING, METAL
COUNTERFLASHING, AND
METAL GRAVEL STOP
REMOVE CONCRETE
SLAB CONSTRUCTION -
SEE STRUCTURAL
DRAWINGS
REMOVE CONCRETE
SIDEWALK - SEE CIVIL
DRAWINGS
REMOVE PRECAST CONCRETE WINDOW SILL
REMOVE MASONRY TIES
REMOVE AND SALVAGE OR REMOVE AND DEMOLISH
OUTSIDE AIR INTAKE LOUVER COMPLETE - SEE
SHEETS AD201 & AD202
B
RI
CK
S
'-0
9'-
4"
B
RI
CK
S
3'- 4"
8 B
RI
CK
S
1'-
B
RI
CK
S
2'- 8"
6'-
8"
B
RI
CK
S
B
RI
CK
S
FIRST FLOOR
0"
SECOND FLOOR
12'-8"
T.O.J.
24'-6"
D
EXISTING CONCRETE
FOUNDATION TO REMAIN
REMOVE STEEL SHELF ANGLE - SEE
STRUCTURAL DRAWINGS
FLOOR SLAB AND ASSOCIATED
STRUCTURAL ELEMENTS TO
REMAIN - SEE STRUCTURAL
DRAWINGS
REMOVE ALL LOOSE BALLASTED
ROOF GRAVEL COMPLETE
REMOVE ROOF CONSTRUCTION
COMPLETE
ROOF STRUCTURE TO REMAIN - SEE
STRUCTURAL DRAWINGS
REMOVE GRAVEL STOP AND
ASSOCIATED CONSTRUCTION
COMPLETE
REMOVE INTERIOR CMU WALL AS
REQUIRED FOR INSTALLATION OF
STEEL STRUCTURE
INTERIOR CMU WALL TO REMAIN
REMOVE EXTERIOR BRICK
VENEER
REMOVE MASONRY TIES
REMOVE HOLLOW METAL FRAME
AND DOOR SYSTEM COMPLETE
EXISTING CONCRETE
LANDING TO REMAIN - SEE
STRUCTURAL DRAWINGS
REMOVE AND SALVAGE OR
REMOVE AND DEMOLISH OUTSIDE
AIR INTAKE LOUVER COMPLETE -
SEE SHEETS AD201 & AD202
B
RI
CK
S
'-1
0"
B
RI
CK
S
2'- 8"
B
RI
CK
S
'-0
FIRST FLOOR
0"
SECOND FLOOR
12'-8"
T.O.J.
24'-6"
C
REMOVE ALUMINUM WINDOW
SYSTEM COMPLETE AND SALVAGE
FOR REINSTALLATION
REMOVE CERAMIC TILE WINDOW
SILL CONSTRUCTION COMPLETE
FLOOR SLAB AND ASSOCIATED
STRUCTURAL ELEMENTS TO REMAIN -
SEE STRUCTURAL DRAWINGS
REMOVE ALL LOOSE BALLASTED
ROOF GRAVEL COMPLETE
REMOVE ROOF CONSTRUCTION
COMPLETE
ROOF STRUCTURE TO REMAIN - SEE
STRUCTURAL DRAWINGS
REMOVE GRAVEL STOP AND
ASSOCIATED CONSTRUCTION
COMPLETE
REMOVE INTERIOR CMU WALL AS
REQUIRED FOR INSTALLATION OF
STEEL STRUCTURE
CUT BACK AND REMOVE EXISTING CEILING
AS REQUIRED FOR REINSTALLATION OF
WINDOW SYSTEM AND INSTALLATION OF
STEEL STRUCTURE
REMOVE PRECAST CONCRETE
WINDOW SILL
REMOVE MASONRY TIES
REMOVE INTERIOR CMU WALL AS
REQUIRED FOR INSTALLATION OF
STEEL STRUCTURE
REMOVE STEEL SHELF ANGLE -
SEE STRUCTURAL DRAWINGS
REMOVE ALUMINUM WINDOW
SYSTEM COMPLETE AND SALVAGE
FOR REINSTALLATION
REMOVE CERAMIC TILE WINDOW
SILL CONSTRUCTION COMPLETE
CUT BACK AND REMOVE EXISTING CEILING
AS REQUIRED FOR REINSTALLATION OF
WINDOW SYSTEM AND INSTALLATION OF
STEEL STRUCTURE
REMOVE PRECAST CONCRETE
WINDOW SILL
REMOVE EXTERIOR BRICK VENEER
REMOVE MASONRY TIES
REMOVE INTERIOR CMU WALL AS
REQUIRED FOR INSTALLATION OF
STEEL STRUCTURE
REMOVE EXTERIOR BRICK VENEER
INTERIOR CMU WALL TO REMAIN
EXISTING CONCRETE FOUNDATION
TO REMAIN
REMOVE AND SALVAGE OR REMOVE AND
DEMOLISH OUTSIDE AIR INTAKE LOUVER
COMPLETE - SEE SHEETS AD201 & AD202
B
RI
CK
S
6'- 8"
B
RI
CK
S
3'- 4"
B
RI
CK
S
9'- 4"
B
RI
CK
S
3'- 4"
4 B
RI
CK
S
1'-
B
RI
CK
S
6'- 8"
B
RI
CK
S
2'- 8"
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
DRAWFORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
C O
M M
AN
D
M
ID
-A
TL
AN
TI
C
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
UN
CL
AS
SI
FI
ED
PW
D
N O
R
FO
LK
AD301
B U
IL
D
IN
G
S P
-2
W
AL
L
SE
CT
IO
NS
DE
M
O
LI
TI
O
N
LAB
12,821,002
SAR SAR
02/15/21
MICHAEL COMPTON, CNATTU
EX
TE
RI
O
R
RE
PA
IR
S
RO
O
F
RE
NO
VA
TI
O
N
SEBASTIAN A. RAMOS, R.A.
1576521
N/A
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
TA
TI
ON
S. M. SWEENEY, P.E.
0 9" 1'-6" 3'SCALE: 3/4" = 1'-0" (AD101)
WALL SECTION - DEMOLITIONA1 0 9" 1'-6" 3'SCALE: 3/4" = 1'-0" (AD101)
WALL SECTION - DEMOLITIONA2 0 9" 1'-6" 3'SCALE: 3/4" = 1'-0" (AD101)
W…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .