Room_Requirments_Break_Room.docx
DOCX document 19 KB Posted
- Solicitation number
- N4008518R0617
About this file
Room_Requirments_Break_Room.docx
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 0012.pdf | ||
| Amendment_0011.pdf | ||
| P977_REVISEDPrice_Proposal_Form.pdf | ||
| Amendment_0010.pdf | ||
| Amendment_0009.pdf | ||
| P977_REVISEDPrice_Proposal_Form.docx | DOCX document | |
| AMENDMENT_0008.pdf | ||
| GEOTECH_REPORT_DATED_Feb_2_18.pdf | ||
| P977_sitevisitAttendees000.pdf | ||
| Map1.pdf | ||
| Albany_Motels.pdf | ||
| Amendment_0007__PHASE_II.pdf | ||
| P977_Price_Proposal_Form.docx | DOCX document | |
| 0006.pdf | ||
| Amendment_0005.pdf | ||
| Amendment_0004.pdf | ||
| Amendment_0003.pdf | ||
| Amend_0002.pdf | ||
| 0001.pdf | ||
| Attachment_A_-_Construction_and_Design_Experience_Project_Data_Sheet.docx | DOCX document | |
| Attachment_B_-_Past_Performance_Questionnaire.docx | DOCX document | |
| Attachment_C_-_Small_Business_Subcontracting_Record.docx | DOCX document | |
| RFP.pdf |
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
P977 Combat Vehicle Warehouse Work Order Number: 1581683 MCLB, Albany, GA
Break Room
Space Characteristics
Function/adjacencies: Space set aside for coffee breaks, snacks, lunches, etc.
Special Dimensions:
Ideal Plan Dimensions: See 4.1 Space Tabulation Minimum Ceiling Height: 10’-0”
Acoustics: No special provisions required.
Access: See adjacency drawing in PART 6-ARCHITECTURAL ATTACHMENTS.
Number of Occupants: N/A
Other/Special Requirements: Provide refrigerators commensurate with anticipated use and occupancy.
FF&E Information for Coordination:
FF&E and AV Equipment will be funded separately as a modification to the construction contract. Infrastructure to support all FF&E and AV is included in the construction contract.
| Uniformat Section |
| Description |
| Qty |
| Size |
| Specific Requirements |
| C101001 |
| Interior Partitions |
Painted CMU.
| C102001 |
| Standard Interior Doors |
Flush, hollow metal w/acoustic insulation between 1-3/4” metal faces. Hollow metal frames fully welded with no visible seams; Provide lockable door into storage bay
| C102007 |
| Interior Door Hardware |
Door hardware shall have a stainless steel finish. Provide full mortise locksets with lever handles.
| C103003 |
| Marker Boards |
| 4x6 |
| Provide one dry-erase marker board. |
| C103004 |
| Identifying Devices |
| AR |
| AR |
| Provide at each door; shall meet DoD ABA requirements. |
| C103008 |
| Counters |
Provide solid surface countertops along one wall. Provide openings for double bowl sink and trash can access.
| C103009 |
| Cabinets |
Provide cabinets and solid surface countertops along one wall. Allow space for full size refrigerator(s), and under-counter ice maker.
| C3020 |
| Floor Finishes |
Epoxy Resinous Flooring.
| C302007 |
| Wall Base |
| 6” High |
| Rubber cove base at CMU Wall. Provide clear silicone sealer bead to ensure adhesion to CMU wall. |
| C3010 |
| Wall Finishes |
Painted CMU.
| C303001 |
| Ceiling Finishes |
| 24”x24” |
| Acoustical ceiling tile. |
| C304001 |
| Interior Coatings |
| AR |
| AR |
| MPI Int 4.2R: Epoxy High build on interior CMU partitions. |
| D201004 |
| Sinks |
Provide stainless steel double bowl countertop sink.
| D202005 |
| Specialties |
Provide connector box for the undercounter ice maker in the FF&E package.
| D30 |
| Heating and Ventilation |
Provide HVAC.
| D40 |
| Fire Protection |
1-hour separation required between warehouse areas and office. Provide fire alarm and fire sprinklers.
| D50 |
| Electrical Distribution |
Provide electrical outlets, one per wall, lighting, etc. Provide electrical outlets for each appliance in the FF&E package. Coordinate locations with interior designer.
| E2020 |
| Movable Furnishings |
Furnishings will be provided as part of the FF&E package. See Collateral Equipment Summary