This file attachment provides final drawings related to a small business multiple award construction contract solicitation. The solicitation number is N4008023R0022 issued by the Department of the Navy Naval Facilities Engineering Command for construction services at the Walter Reed National Military Medical Center Building 9. Responses were due on an unspecified date, with multiple awards to be made for an indefinite delivery/indefinite quantity of construction projects over the life of the contracts. Pricing will be conducted on a firm-fixed-price basis for individual task orders. The solicitation targets small businesses and appears to be a vehicle for ongoing construction and renovation requirements at the medical center facility.
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NAVAL FACILITIES ENGINEERING COMMAND (NAVFAC)
WALTER REED NATIONAL MILITARY MEDICAL CENTER
BETHESDA, MD
1. ARCHITECT:
MTFA ARCHITECTURE INC.
3200 LEE HIGHWAY
ARLINGTON, VA 22207
2. STRUCTURAL ENGINEER:
MCMULLAN CONSULTING ENGINEERS
11800 SUNRISE VALLEY DR., SUITE 430
RESTON, VA 20191
3. MECHANICAL, ELECTRICAL, AND PLUMBING:
SUMMER CONSULTANTS, INC.
7900 WESTPARK DRIVE, SUITE A405
MCLEAN, VA 22102
4. FIRE PROTECTION / LIFE SAFETY:
JENSEN HUGHES, INC.
4601 N. FAIRFAX DRIVE, SUITE 1200
ARLINGTON, VA 22203
5. INTERIORS:
DBI ARCHITECTS, INC.
1984 ISAAC NEWTON SQUARE WEST, SUITE 400
RESTON, VA 20190
6. COST ESTIMATOR:
RIB U.S. COST
241 GARRISONVILLE RD., SUITE 202
STAFFORD, VA 22554
7. SECURITY:
STONE SECURITY ENGINEERING
2011 CRYSTAL DR, SUITE 400
ARLINGTON, VA 22202
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
W A
S H
IN
G
T O
N N
A V
A L
S U
P P
O R
T A
C T
IV
IT
Y B
E T
H E
S D
A M
A R
Y L
A N
D
AS NOTED
P U
B L
IC
W
O R
K S
D E
P A
R T
M E
N T
B
E T
H E
S D
A
3200 LEE HIGHWAY, ARLINGTON, VA 22207
(703) 524 - 6616 www.mtfa.net
PROFESSIONAL CERTIFICATION. I
CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME AND
THAT I AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF
MARYLAND, LICENSE NUMBER 9635,
EXPIRATION DATE 8/15/23.
/1
/2
:4
:5
A
M
G-001
B U
IL
D
IN
G
E
N T
R A
N C
E A
N D
C O
R R
ID
O
R
M O
D E
R N
IZ
A
T
IO
N
C O
V E
R S
H E
E T
MJB
13143612
PJ CM
FINAL DESIGN SUBMISSION
1677850
B E
T H
E S
D A
, M D
W A
LT
E
R R
E E
D N
A T
IO
N
A L
M
IL
IT
A
R Y
M E
D
IC
A L
C E
N T
E R
G -0
F
IN
A
L D
E S
IG
N
S U
B M
IS
S
IO
N
/1
/2
/1
7/
F
IN
A
L D
E S
IG
N
S U
B M
IS
S
IO
N
VICINITY MAP (NTS)
LOCATION MAP (NTS)
PROJECT SITE
PROJECT TEAM DRAWING INDEX
TRUE
NORTH
TRUE
NORTH
BUILDING 9 ENTRANCE AND CORRIDOR MODERNIZATION
FINAL DESIGN SUBMISSION - MAY 17, 2022
WALTER REED NATIONAL MILITARY MEDICAL CENTER, BETHESDA, MD.
SHEET # NAVFAC_NO SHEET NAME
MD101 13143729 FIRST FLOOR AREA B - DEMOLITION
MD102 13143730 FIRST FLOOR AREA C - DEMOLITION
07-Mechanical
M-101 13143731 FIRST FLOOR AREA B
M-102 13143732 FIRST FLOOR AREA C
M-501 13143733 DETAILS
M-601 13143734 SCHEDULES
08-Electrical
E-001 13143735 SYMBOLS & ABBREVIATIONS
ED101 13143736 FIRST FLOOR AREA A - DEMOLITION
ED102 13143737 FIRST FLOOR AREA B - DEMOLITION
ED103 13143738 FIRST FLOOR AREA C & D - DEMOLITION
ED104 13143739 SECOND FLOOR AREA A - DEMOLITION
ED105 13143740 SECOND FLOOR AREA B - DEMOLITION
ED106 13143741 SECOND FLOOR AREA C - DEMOLITION
08-Electrical
E-101 13143742 FIRST FLOOR LIGHTING AREA A
E-102 13143743 FIRST FLOOR LIGHTING AREA B
E-103 13143744 FIRST FLOOR LIGHTING AREA C & D
E-104 13143745 SECOND FLOOR LIGHTING AREA A
E-105 13143746 SECOND FLOOR LIGHTING AREA B
E-106 13143747 SECOND FLOOR LIGHTING AREA C
E-107 13143748 FIRST FLOOR POWER AREA A
E-108 13143749 FIRST FLOOR POWER AREA B
E-109 13143750 FIRST FLOOR POWER AREA C
E-110 13143751 SECOND FLOOR POWER AREA A
E-111 13143752 SECOND FLOOR POWER AREA B
E-501 13143753 LIGHTING DETAILS
E-601 13143754 RISER DIAGRAMS
E-701 13143755 SWITCHBOARD SCHEDULE
E-702 13143756 PANEL SCHEDULE
E-703 13143757 PANEL SCHEDULE
E-704 13143758 PANEL SCHEDULE
E-705 13143759 PANEL SCHEDULE
90-Fire Alarm
FA001 13143760 FIRE ALARM NOTES AND LEGEND
FAD101 13143761 FIRE ALARM DEMOLITION FIRST FLOOR PLAN - AREA A
FAD102 13143762 FIRE ALARM DEMOLITION FIRST FLOOR PLAN - AREA B
FAD103 13143763 FIRE ALARM DEMOLITION FIRST FLOOR PLAN - AREA C
FAD104 13143764 FIRE ALARM DEMOLITION SECOND FLOOR PLAN - AREA A
FAD105 13143765 FIRE ALARM DEMOLITION SECOND FLOOR PLAN - AREA B
FAD106 13143766 FIRE ALARM DEMOLITION SECOND FLOOR PLAN - AREA C
90-Fire Alarm
FA101 13143767 FIRE ALARM FIRST FLOOR PLAN - AREA A
FA102 13143768 FIRE ALARM FIRST FLOOR PLAN - AREA B
FA103 13143769 FIRE ALARM FIRST FLOOR PLAN - AREA C
FA104 13143770 FIRE ALARM SECOND FLOOR PLAN - AREA A
FA105 13143771 FIRE ALARM SECOND FLOOR PLAN - AREA B
FA106 13143772 FIRE ALARM SECOND FLOOR PLAN - AREA C
Sheet Grand Total: 162
SHEET # NAVFAC_NO SHEET NAME
A-405 13143673 ENLARGED CHECK-IN STATION PLANS - ULTRASOUND
A-406 13143674 ENLARGED CHECK-IN STATION PLANS - GENERAL SURGERY
A-407 13143675 ENLARGED CHECK-IN STATION PLANS - MAXILLOFACIAL
A-408 13143676 ENLARGED CHECK-IN STATION PLANS - HOSPITAL DENTISTRY
A-409 13143677 ENLARGED CHECK-IN STATION PLANS - PLASTIC SURGERY
A-410 13143678 ENLARGED CHECK-IN STATION PLANS - SLEEP DISORDER
A-411 13143679 PATIENT RELATIONS
A-412 13143680 PATIENT RELATIONS - BREAK & COPY ROOM
A-413 13143681 RADIOLOGY - CAFE
A-414 13143682 PHARMACY FLOOR PLAN & ELEVATION
A-421 13143683 ENLARGED STAIR PLANS AND SECTIONS
A-422 13143684 STAIR DETAILS
A-423 13143685 ENLARGED INFORMATION DESK PLANS
A-431 13143686 EAST ENTRANCE
A-432 13143687 EAST ENTRANCE - DETAILS
A-501 13143688 CEILING DETAILS
A-502 13143689 CEILING DETAILS
A-510 13143690 PATIENT RELATIONS DETAILS
A-601 13143691 PARTITION SCHEDULE
A-602 13143692 DOOR SCHEDULE
A-701 13143693 MILLWORK DETAILS
A-702 13143694 PHARMACY MILLWORK DETAILS
A-703 13143695 CAFE MILLWORK
A-704 13143696 MILLWORK DETAILS
04-Architectural - Finishes
AF101 13143697 OVERALL FIRST FLOOR FINISH PLAN
AF102 13143698 FIRST FLOOR FINISH PLAN - AREA A
AF103 13143699 FIRST FLOOR FINISH PLAN - AREA B
AF104 13143700 FIRST FLOOR FINISH PLAN - AREAS C & D
AF105 13143701 FIRST FLOOR FINISH PLAN - PATIENT RELATIONS
AF106 13143702 OVERALL SECOND FLOOR FINISH PLAN
AF107 13143703 SECOND FLOOR FINISH PLAN - AREA A
AF108 13143704 SECOND FLOOR FINISH PLAN - AREA B
AF109 13143705 SECOND FLOOR FINISH PLAN - AREA C
AF110 13143706 FINISH SCHEDULE & DETAILS
AF111 13143707 FINISH BOARD
04.1-Interior Furniture
IF101 13143708 LEVEL 1 - FURNITURE PLAN
IF102 13143709 LEVEL 1 - ENLARGED FURNITURE PLANS
IF201 13143710 LEVEL 2 - FURNITURE PLAN
IF202 13143711 LEVEL 2 - ENLARGED FURNITURE PLANS
IF301 13143712 FURNITURE SCHEDULES
05-Fire Protection
FX001 13143713 FIRE SUPPRESSION NOTES AND LEGEND
05-Fire Protection
FD101 13143714 FIRE SUPPRESSION FIRST FLOOR DEMOLITION - AREA A
FD102 13143714 FIRE SUPPRESSION FIRST FLOOR DEMOLITION - AREA B
FD103 13143715 FIRE SUPPRESSION FIRST FLOOR DEMOLITION - AREA C
FD104 13143716 FIRE SUPPRESSION SECOND FLOOR DEMOLITION - AREA A
FD105 13143717 FIRE SUPPRESSION SECOND FLOOR DEMOLITION - AREA B
FD106 13143718 FIRE SUPPRESSION SECOND FLOOR DEMOLITION - AREA C
05-Fire Protection
FX101 13143719 FIRE SUPPRESSION FIRST FLOOR PLAN - AREA A
FX102 13143720 FIRE SUPPRESSION FIRST FLOOR PLAN - AREA B
FX103 13143721 FIRE SUPPRESSION FIRST FLOOR PLAN - AREA C
FX104 13143722 FIRE SUPPRESSION SECOND FLOOR PLAN - AREA A
FX105 13143723 FIRE SUPPRESSION SECOND FLOOR PLAN - AREA B
FX106 13143724 FIRE SUPPRESSION SECOND FLOOR PLAN - AREA C
06-Plumbing
P-001 13143725 SYMBOLS & ABBREVIATIONS
PD101 13143726 FIRST FLOOR AND BASEMENT DEMOLITION
06-Plumbing
P-101 13143727 FIRST FLOOR AND BASEMENT
07-Mechanical
M-001 13143728 SYMBOLS & ABBREVIATIONS
SHEET # NAVFAC_NO SHEET NAME
01-General
G-001 13143612 COVER SHEET
G-002 13143613 GENERAL NOTES, ABBREVIATIONS AND SYMBOLS
02-Life Safety
GI001 13143614 LIFE SAFTEY NOTES AND LEGEND
GI101 13143615 EXISTING LIFE SAFETY FIRST FLOOR PLAN
GI102 13143616 EXISTING LIFE SAFETY SECOND FLOOR PLAN
GI103 13143617 NEW LIFE SAFETY FIRST FLOOR PLAN
GI104 13143618 NEW LIFE SAFETY PLAN SECOND FLOOR
03-Structural
S-001 13143619 DESIGN NOTES
S-002 13143620 DESIGN NOTES AND ABBREVIATIONS
S-101 13143621 FIRST FLOOR PARTIAL FRAMING PLAN
S-102 13143622 SECOND FLOOR PARTIAL FRAMING PLAN
S-501 13143623 SECTIONS AND DETAILS
S-502 13143624 SECTIONS AND DETAILS
04-Architectural - Demolitition
AD101 13143625 OVERALL FIRST FLOOR DEMOLITION
AD102 13143626 FIRST FLOOR DEMOLITION - AREA A
AD103 13143627 FIRST FLOOR DEMOLITION - AREA B
AD104 13143628 FIRST FLOOR DEMOLITION - AREA C & D
AD105 13143629 OVERALL SECOND FLOOR PLAN
AD106 13143630 SECOND FLOOR DEMOLITION - AREA A
AD107 13143631 SECOND FLOOR DEMOLITION - AREA B
AD108 13143632 SECOND FLOOR DEMOLITION - AREA C
AD109 13143633 ENLARGED DEMOLITION FLOOR PLAN - PATIENT RELATIONS
AD111 13143634 REFLECTED CEILING PLAN DEMO - FIRST FLOOR
AD112 13143635 REFLECTED CEILING PLAN DEMO - FIRST FLOOR AREA A
AD113 13143636 REFLECTED CEILING PLAN DEMO - FIRST FLOOR AREA B
AD114 13143637 REFLECTED CEILING PLAN DEMO - FIRST FLOOR AREA C & D
AD115 13143638 REFLECTED CEILING PLAN DEMO - SECOND FLOOR
AD116 13143639 REFLECTED CEILING PLAN DEMO - SECOND FLOOR AREA A
AD117 13143640 REFLECTED CEILING PLAN DEMO - SECOND FLOOR AREA B
AD118 13143641 REFLECTED CEILING PLAN DEMO - SECOND FLOOR AREA C
AD119 13143642 ENLARGED DEMOLITION RCP - PATIENT RELATIONS
AD201 13143643 BUILDING ENTRY ELEVATIONS
AD301 13143644 SECTIONS
AD310 13143645 ENLARGED SECTIONS
AD311 13143646 ENLARGED SECTIONS
AD312 13143647 ENLARGED SECTIONS
04-Architectural
A-101 13143648 OVERALL FIRST FLOOR PLAN
A-102 13143649 FIRST FLOOR PLAN - AREA A
A-103 13143650 FIRST FLOOR PLAN - AREA B
A-104 13143651 FIRST FLOOR PLAN - AREA C & D
A-105 13143652 OVERALL SECOND FLOOR PLAN
A-106 13143653 SECOND FLOOR PLAN - AREA A
A-107 13143654 SECOND FLOOR PLAN - AREA B
A-108 13143655 SECOND FLOOR PLAN - AREA C
A-109 13143656 ENLARGED FLOOR PLAN - PATIENT RELATIONS
A-111 13143657 REFLECTED CEILING PLAN - FIRST FLOOR
A-112 13143658 REFLECTED CEILING PLAN - FIRST FLOOR AREA A
A-113 13143659 REFLECTED CEILING PLAN - FIRST FLOOR AREA B
A-114 13143660 REFLECTED CEILING PLAN - FIRST FLOOR AREA C & D
A-115 13143661 REFLECTED CEILING PLAN - SECOND FLOOR
A-116 13143662 REFLECTED CEILING PLAN - SECOND FLOOR AREA A
A-117 13143663 REFLECTED CEILING PLAN - SECOND FLOOR AREA B
A-118 13143664 REFLECTED CEILING PLAN - SECOND FLOOR AREA C
A-119 13143665 ENLARGED REFLECTED CEILING PLAN - PATIENT RELATIONS
A-301 13143666 BUILDING SECTIONS
A-310 13143667 ENLARGED SECTIONS
A-311 13143668 ENLARGED SECTIONS
A-401 13143669 ENLARGED CHECK-IN STATION PLANS - NEUROSURGERY
A-402 13143670 ENLARGED CHECK-IN STATION PLANS - GASTROENTEROLOGY
A-403 13143671 ENLARGED CHECK-IN STATION PLANS - NEPHROLOGY
A-404 13143672 ENLARGED CHECK-IN STATION PLANS - PULMONARY
PROJECT AREA
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
ABBREV ABBREVIATIONS
ABV ABOVE
ACOUS ACOUSTICAL
ACT ACOUSTICAL CEILING TILE
ADJ ADJUSTABLE
AFF ABOVE FINISH FLOOR
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
ANC ANCHORS
APPROX APPROXIMATE
ARCH ARCHITECTURAL
A/V AUDIO/VISUAL
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
BO BY OWNER
BOT BOTTOM
BTM BOTTOM
BRD BOARD
BRKT BRACKET
BR BULLET RESISTANT
BU BUILT-UP
CAB CABINET
CEM CEMENTITIOUS
CF CUBIC FOOT (FEET)
CI CAST IRON
CJ CONTROL JOINT
CLG CEILING
CLL CONTRACT LIMIT LINE
CL CLOSET
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CNR CORNER
CO CLEAN OUT
COL COLUMN
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS
CS COURSES
CPT CARPET
CT CERAMIC TILE
CTR CENTER
CTSK COUNTER SUNK
DBL DOUBLE
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
MTD MOUNTED
N NORTH
N/A NOT APPLICABLE
NIC NOT IN CONTRACT
NR NOT RATED
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFF OFFICE
OFCI OWNER FURNISHED/ CONTRACTOR INSTALLED
OH OVERHEAD
OPG OPENING
OPHD OPPOSITE HAND
OPP OPPOSITE
PAR PARTIAL
PTN PARTITION
PED PEDESTRIAN
PLAM PLASTIC LAMINATE
PLX PLEXIGLASS
PLYWD PLYWOOD
PNL PANEL
POL POLISH(ED)
PR PAIR
PREFAB PREFABRICATED
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT
PTD PAINTED
QT QUARRY TILE
QTY QUANTITY
RAD RADIUS
RD ROOF DRAIN
RCP REFLECTED CEILING PLAN
REF REFERENCE
REFG REFRIGERATOR
REINF REINFORCED (ING)
REQ'D REQUIRED
RES RESILIENT
REV REVISE (REVISION)
RM ROOM
RO ROUGH OPENING
RTU ROOF TOP UNIT
SC SOLID CORE
SCHED SCHEDULE (SCHEDULED)
SCWD SOLID CORE WOOD DOOR
SECT SECTION
SF SQUARE FOOT (FEET)
SFPS STRETCHED FABRIC PNL. SYS
DH DOUBLE-HUNG
DIA DIAMETER
DIFF DIFFUSER
DIM DIMENSION
DISP DISPENSER
DIV DIVISION (DIVIDED)
DN DOWN
DS DOWN SPOUT
DR DOOR
DW DISHWASHER
DWG DRAWING
DWGS DRAWINGS
DWR DRAWER
E EAST
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
ENCL ENCLOSURE
ENT ENTRANCE
EQ EQUAL
EQUIP EQUIPMENT
ETR EXISTING TO REMAIN
EWC ELECTRIC WATER COOLER
EX EXISTING
EXP EXPANSION
EXT EXTERIOR
FA FIRE ALARM
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FG FINISH GRADE
FT FOOT (FEET)
FF FINISHED FLOOR
FF&E FIXTURE FURNITURE & EQUIPMENT
FVC FIRE VALVE CABINET
FIN FINISH
FLR FLOOR(ING)
FLEX FLEXIBLE
FLSG FLASHING
FLUOR FLUORESCENT
FR FRAME
FRPF FIRE PROOFING
FRT FIRE RETARDANT TREATED
FTG FOOTING
FUR FURRING
GA GAUGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GL GLASS
GOV'T GOVERNMENT
GR GRADE
GWB GYPSUM WALLBOARD
HB HOSE BIB
HC HOLLOW CORE
HD HEAVY DUTY
HDWD HARDWOOD
HDWE HARDWARE
HT HEIGHT
HM HOLLOW METAL
HORIZ HORIZONTAL
HP HIGH POINT
HR HOUR
HVAC HEATING VENT, AIR COND
ID INSIDE DIAMETER
IGU INSULATED GLASS UNIT
INFO INFORMATION
INST INSTALLATION
INSUL INSULATION
INT INTERIOR
JAN JANITOR
JST JOIST
JT JOINT
KD KNOCK DOWN
KIT KITCHEN
KO KNOCK OUT
LAM LAMINATED
LAV LAVATORY
LIN LINEAR
LP LOWPOINT
LT LIGHT
LW LIGHTWEIGHT
MACH MACHINE
MAINT MAINTENANCE
MATL MATERIAL
MAX MAXIMUM
MB MARKER BOARD
MDF MEDIUM DENSITY FIBERBOARD
MECH MECHANICAL
MEMB MEMBRANE
MTL METAL
MEZZ MEZZANINE
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MLDG MOLDING
MO MASONRY OPENING
MOD MODIFIED
MWP METAL WALL PANEL
MR MOISTURE RESISTANT
SHT SHEET
SIM SIMILAR
SHR SHOWER
SL SLIDING
SPEC SPECIFICATION
SQ SQUARE
SSK SERVICE SINK
SS STAINLESS STEEL
ST STAIN(ED)
STA STATION
STC SOUND TRANSMISSION CLASS
STD STANDARD
STL STEEL
STN STAIN
STR STAIR
STOR STORAGE
STRUCT STRUCTURAL
SUSP SUSPENDED
SW SWITCH
SYM SYMMETRICAL
SYS SYSTEM
TB TACK BOARD
TBR TO BE REMOVED
TEL TELEPHONE
TEMP TEMPERED
T&G TONGUE & GROOVE
THK THICK
THR THRESHOLD
TLT TOILET
TO TOP OF
TOS TOP OF SLAB
TOSTL TOP OF STEEL
TV TELEVISION
TYP TYPICAL
UL UNDERWRITER'S LABORATORIES
UNF UNFINISHED
UNO UNLESS NOTIFIED OTHERWISE
UON UNLESS OTHERWISE NOTED
UR URINAL
UTL UTILITY
VCT VINYL COMPOSITE TILE
VERT VERTICAL
VIF VERIFY IN FIELD
VEST VESTIBULE
W WEST
W/ WITH
WD WOOD
WH WATER HEATER
W/O WITH OUT
WP WATERPROOFING
WR WATER RESISTANT
WT WEIGHT
PARTITION TYPE
COLUMN REFERENCE
DETAILS
INTERIOR ELEVATION
REFERENCE
BUILDING / WALL SECTION
EXTERIOR ELEVATION REFERENCE
DRAWING TITLE
KEY NOTE
(First number indicates specification division)
WINDOW / LOUVER / GLASS TYPE
ROOM NAME & NUMBER
REVISION
SPOT ELEVATION
DOOR NUMBER
A101
A101
A101
A101
VEW #
SHT #
DRAWING TITLE
SCALE
DRAWING TITLE
BACK REFERENCED
VEW #
SHT
DRAWING TITLE
SCALEREF
A101
ROOM
NAME
9'-0" CEILING HEIGHT A.F.F.
ACT-1 CEILING MATERIAL
1a
W1a
CONCRETE MASONRY
CUT BLOCKING / SHIM
WOOD BLOCKING
RIGID INSULATION
BATT INSULATION
CONCRETE
BRICK
FINISH WOOD / HARD WOOD
SEALANT / CAULKING
ENGINEERED FILL
STEEL
GYPSUM
1. WORK MUST BE PERFORMED IN ACCORDANCE WITH RULES AND REGULATIONS OF GOVERNMENT AGENCIES HAVING JURISDICTION AND MUST CONFORM TO ALL ARCHITECTURAL BARRIERS ACT (ABA) AND THE AMERICANS WITH DISABILITIES AND ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABAAS), NFPA, CITY, COUNTY, STATE, AND FEDERAL CONSTRUCTION, SAFETY, AND SANITARY LAW, CODES, STATUTES, AND ORDINANCES.
2. ALL CONTRACTORS MUST BE RESPONSIBLE FOR VISITING THE SITE AND EXAMINING EXISTING CONDITIONS PRIOR TO SUBMITTING A BID FOR THE WORK.
3. CONSTRUCTION OF WORK INDICATED ON THE DRAWINGS AS (N.I.C.) IS NOT IN CONTRACT.
4. WHERE SPECIFIC DIMENSIONS, DETAILS OR DESIGN INTENT CANNOT BE DETERMINED, CONSULT GOVERNMENT BEFORE PROCEEDING WITH THE WORK. TYPICAL DETAILS
APPLY AT ALL SIMILAR CONDITIONS WHETHER CROSS REFERENCED OR NOT.
5. REQUIRED WORK OF A TRADE MAY BE AFFECTED BY INFORMATION ON OTHER TRADE SHEETS. ALL BIDS ARE BASED ON EXAMINATION OF A FULL SET OF DOCUMENTS.
THE CONTRACTOR MUST COORDINATE THE WORK OF ALL TRADES AND SUBCONTRACTORS.
6. DIMENSION UNITS ARE IMPERIAL UNITS UNLESS NOTED OTHERWISE.
7. DIMENSIONS SHOWN ARE TO THE FINISHED FACE, CENTER-LINE OF DOOR OPENING AND COLUMN GRID LINES UNLESS NOTED OTHERWISE.
8. "VIF" OR ± INDICATED DIMENSIONS MUST BE FIELD VERIFIED. WHEN ACTUAL FIELD DIMENSIONS VARY IN SUCH A WAY THAT IT AFFECTS ELEMENTS WITHIN THE STRING, NOTIFY GOVERNMENT IMMEDIATELY.
9. DO NOT SCALE DRAWINGS. WHERE DIMENSIONS OR EXACT LOCATIONS ARE REQUIRED AND NOT INCLUDED ON THE DRAWINGS, REQUEST INFORMATION FROM
GOVERNMENT.
10. THE INFORMATION CONTAINED HEREIN MAY REQUIRE ADJUSTMENT OR MODIFICATION TO CONFORM TO EXISTING CONDITIONS. IN CASES WHERE CHANGES IN DETAILS
ARE NECESSARY, THESE DRAWINGS ARE USED TO SHOW ONLY THE DESIGN INTENT.
11. INSTALL MATERIALS, EQUIPMENT, HARDWARE, AND OTHER ELEMENTS IN STRICT COMPLIANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS AND RECOMMENDATIONS. COORDINATE LOCATION OF CONCEALED SUPPORTS OR BLOCKING TO ENSURE PROPER INSTALLATION PRIOR TO CLOSING OF WALLS.
12. ALL DAMAGE TO EXISTING CONSTRUCTION AND PROPERTY BY THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE NAVFAC CM, RECEIVE DIRECTION AND BE REPLACED AT
THE CONTRACTOR'S EXPENSE WITH NEW MATERIALS TO MATCH EXISTING.
13. ELECTROLYTIC PROTECTION MUST BE PROVIDED BETWEEN DISSIMILAR METALS WHENEVER THE TWO ARE IN CONTACT.
14. OPEN EXTERIOR JOINTS AROUND WINDOW AND DOOR FRAMES, BETWEEN WALL PANELS, AT PENETRATIONS OF UTILITIES THROUGH THE BUILDING ENVELOPE MUST BE SEALED, FLASHED OR WEATHER-STRIPPED AS REQUIRED FOR COMPATIBILITY WITH ADJACENT MATERIALS TO ELIMINATE AIR LEAKAGE & WATER INFILTRATION.
15. A FULL AND COMPLETE JOB IS REQUIRED UNDER THIS CONTRACT. MATERIAL AND LABOR WHICH ARE RELATED TO THE WORK BUT NOT SPECIFICALLY INDICATED, AND WHICH ARE REQUIRED FOR A PROFESSIONALLY FINISHED JOB, MUST BE A PART OF THE WORK.
16. WORK IS TO BE PERFORMED IN A FULLY OCCUPIED BUILDING. PERIODS OF SYSTEM INTERRUPTIONS MUST BE APPROVED BY BUILDING MANAGEMENT AND MUST BE LIMITED TO OFF HOURS/DAYS. THE GOVERNMENT AND TENANT REQUIRE A 72 HOUR NOTIFICATION OF SYSTEM INTERRUPTIONS. SEE WORK RESTRICTION IN THE
SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
17. VERIFICATION & ADJUSTMENT OF LAYOUTS IS PART OF THE SCOPE OF WORK. PROVIDE CONFIRMATION OF ALL DIMENSIONS AND LAYOUT WITH THE GOVERNMENT PRIOR TO INSTALLATION OF SYSTEMS. THE CONTRACTOR IS RESPONSIBLE FOR ON-SITE VERIFICATION OF ALL GRADES, FIELD CONDITIONS, QUANTITIES, AND DIMENSIONS
PRIOR TO CONSTRUCTION.
18. THE CONTRACTOR IS RESPONSIBLE FOR PAYMENT OF ALL APPLICABLE PERMITS.
19. THE GENERAL NOTES AND TYPICAL DETAILS APPLY THROUGHOUT THE JOB UNLESS OTHERWISE NOTED OR SHOWN.
20. NO MATERIAL CUTTING OR FABRICATION OF ANY WORK WILL BEGIN UNTIL THE CONTRACTOR HAS RECEIVED WRITTEN AND/OR STAMPED APPROVAL (FROM THE
GOVERNMENT) OF RELATED SHOP DRAWINGS AND MANUFACTURERS' SPECIFICATION DATA.
21. THE CONTRACTOR IS TO PROVIDE CLOSE OUT DOCUMENTATION UPON COMPLETION OF THE PROJECT TO THE NAVFAC. COORDINATE FINAL REQUIREMENTS WITH
GOVERNMENT. GC TO PROVIDE ELECTRONIC AND HARD COPIES OF AS-BUILTS.
22. THE CONTRACTOR MUST MAINTAIN EMERGENCY EGRESS ACCESS AND ENSURE SECURITY OF THE SPACE AT ALL TIMES.
23. WORK MUST BE COMPLETED DURING TYPICAL OPERATION HOURS EXCEPT FOR SHUT DOWNS AND WORK INVOLVING NOISE OR ODORS AND WORK INVOLVING OTHER OCCUPIED FLOORS AND ADJACENT SPACES. WORK INVOLVING NOISE OR ODORS, AND WORK INVOLVING OTHER OCCUPIED FLOORS AND ADJACENT SPACES MUST BE
COORDINATED WITH ADVANCED NOTICE TO NAVFAC CM AND HOSPITAL REP. AS REQUIRED.
24. COMPLETE SPECIFICATIONS ARE TO BE A PART OF THIS CONSTRUCTION DOCUMENT SUBMITTAL.
25. EXISTING FIRE SEPARATION WALLS AND THEIR RATINGS MUST BE MAINTAINED BETWEEN THE CONSTRUCTION AREA AND OCCUPIED AREAS. PROVIDE TEMPORARY FIRE
BARRIERS AS REQUIRED.
THE WORK INCLUDES ARCHITECTURAL DESIGN SERVICES TO MODERNIZE THE EAST HOSPITAL ENTRANCE INCLUDING A RENOVATION OF THE MAIN LOBBY AND SUPPORTING CORRIDORS FOR BUILDING 9. THE EXISTING FRONT CURTAIN WALL IS TO BE REMOVED AND REPLACED WITH A UPDATED CURTAIN WALL SYSTEM. THE NEWLY DESIGNED ENTRANCE WILL INCLUDE EXTERIOR AND INTERIOR BUILDING FINISHES, SAFETY, WEATHER PROTECTION, INFECTION CONTROL, WALKWAYS, ENTRANCE DOORS, LIGHTING, AND HVAC. NEW INTERIOR FEATURES INCLUDE A MONUMENTAL STAIRWAY / INFORMATION DESKS, CHECK-IN STATIONS, VISITOR SEATING / WAITING, ACOUSTICAL TREATMENTS, WALL PANELING, CEILING FINISHES, LED LIGHTING, FIRE PROTECTION SYSTEM UPGRADES, AND INCIDENTAL RELATED WORK.
THE SCOPE OF WORK MAY INITIALLY INCLUDE CORING OF STRUCTURAL SLAB. IF CORING OF STRUCTURAL SLAB IS REQUIRED THEN THE FOLLOWING MUST BE ADHERED TO. CUTTING OF REINFORCEMENT IS NOT PERMITTED. THE CONTRACTOR WILL BE RESPONSIBLE FOR STEEL REINFORCEMENT DETECTION PRIOR TO ANY CORING.
DETECTION METHODS MAY REQUIRE VARIOUS TECHNOLOGIES INCLUDING X-RAYS. DOCUMENTATION OF CORES AND STEEL LOCATIONS MUST BE SUBMITTED BY
CONTRACTOR AND REVIEWED AND APPROVED BY GOVERNMENT PRIOR TO CORING.
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
W A
S H
IN
G
T O
N N
A V
A L
S U
P P
O R
T A
C T
IV
IT
Y B
E T
H E
S D
A M
A R
Y L
A N
D
AS NOTED
P U
B L
IC
W
O R
K S
D E
P A
R T
M E
N T
B
E T
H E
S D
A
3200 LEE HIGHWAY, ARLINGTON, VA 22207
(703) 524 - 6616 www.mtfa.net
PROFESSIONAL CERTIFICATION. I
CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME AND
THAT I AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF
MARYLAND, LICENSE NUMBER 9635,
EXPIRATION DATE 8/15/23.
/1
/2
:4
:5
A
M
G-002
B U
IL
D
IN
G
E
N T
R A
N C
E A
N D
C O
R R
ID
O
R
M O
D E
R N
IZ
A
T
IO
N
G E
N E
R A
L N
O
TE
S , A
B B
R E
V
IA
TI
O
N S
A N
D S
Y M
B O
LS
MJB
13143613
PJ CM
FINAL DESIGN SUBMISSION
1677850
B E
T H
E S
D A
, M D
W A
LT
E
R R
E E
D N
A T
IO
N
A L
M
IL
IT
A
R Y
M E
D
IC
A L
C E
N T
E R
G -0
F
IN
A
L D
E S
IG
N
S U
B M
IS
S
IO
N
/1
/2
/1
7/
F
IN
A
L D
E S
IG
N
S U
B M
IS
S
IO
N
GENERAL NOTES: MATERIAL SYMBOLS: DRAWING SYMBOLS:
ABBREVIATIONS:
REINFORCING PROTECTION:
SCOPE OF WORK:
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
LIFE SAFETY LEGEND
FIRE EXTINGUISHER CABINET (NEW)
FIRE EXTINGUISHER CABINET (EXISTING)
FIRE EXTINGUISHER BRACKET (NEW)
FIRE EXTINGUISHER BRACKET (EXISTING)
X = REQUIRED EGRESS CAPACITY (PERSONS)
Y = PROVIDED EGRESS CAPACITY (PERSONS)
ROOM AREA (SF)
OCCUPANT FACTOR (SF/PERSON)
NUMBER OF OCCUPANTS (PERSONS)
TRAVEL PATH AND DISTANCE
COMMON PATH OF TRAVEL
DEAD-END CORRIDOR
SMOKE PARTITION
1-HOUR SMOKE BARRIER
2-HOUR SMOKE BARRIER
1-HOUR FIRE BARRIER
2-HOUR FIRE BARRIER
KEYNOTE
TD = XXFT
CP = XXFT
1,000
XXXX
XXXX
XXXX
DE = XXFT
XX
XX
D A
T E
A P
P R
D E
S C
R
IP
T
IO
N S
Y M
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
SCALE:
CONSTR. CONTR. NO.
EPROJECT NO.:
SHEET OF
NAVFAC DRAWING NO.
DES: DRW:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
DRAWFORM REVISION: 25 AUGUST 2020
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
W
A S
H
IN
G T
O N
P U
B L
IC
W O
R K
S D
E P
A R
T M
E N
T B
E T
H E
S D
A N
A V
A L
S U
P P
O R
T A
C T
IV
IT
Y B
E T
H E
S D
A M
A R
Y L
A N
D
CHK:
PM / DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
SATISFACTORY-TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
3200 LEE HIGHWAY, ARLINGTON, VA 22207
(703) 524 - 6616 www.mtfa.net
W A
LT
E
R R
E E
D N
A T
IO
N
A L
M
IL
IT
A
R Y
M E
D
IC
A L
C E
N T
E R
B E
T H
E S
D A
, M D
AS NOTED
1677850
FINAL DESIGN SUBMISSION
/1
/2
D
E S
IG
N
S U
B M
IS
S
IO
N
NTR AHE EHA
/2 /2
D
E S
IG
N
S U
B M
IS
S
IO
N
P R
E -F
IN
A
L D
E S
IG
N
S U
B M
IS
S
IO
N
/2 /2
F
IN
A L
D E
S
IG
N S
U B
M
IS
S
IO
N
/1 /2
/1
/2
:0
:5
P
M
L
IF
E S
A F
E T
Y N
O T
E S
A N
D L
E G
E N
D
GI001
B U
IL
D
IN
G
E
N T
R A
N C
E A
N D
C O
R R
ID
O
R M
O D
E R
N
IZ
A T
IO
N
13143614
G I0
P R
E -F
IN
A
L D
E S
IG
N
S U
B M
IS
S
IO
N
/2
/2
APPLICABLE CRITERIA
USE GROUP/OCCUPANCY
FIRE PROTECTION SYSTEMS
INTERIOR FINISH CLASSIFICATION
OCCUPANT LOAD
LIMITATIONS FOR TYPE IA CONSTRUCTION
TYPE IA RESISTANCE RATINGS (IN HOURS) OF STRUCTURAL ELEMENTS
[IBC TABLE 601]
FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS OF
TYPE IA BUILDINGS [IBC TABLE 602]
INTERIOR FIRE RESISTANCE REQUIREMENTS
• UNIFIED FACILITIES CRITERIA UFC 3-600-01, FIRE PROTECTION ENGINEERING FOR FACILITIES (UFC) –
AUGUST 2016 WITH CHANGES MAY 2021
• UFC 1-200-01, GENERAL BUILDING REQUIREMENTS, 2020
• UFC 4-021-01 – DESIGN AND O&M: MASS NOTIFICATION SYSTEMS, APRIL 9, 2008 WITH CHANGE 1, JANUARY 2010
• ICC INTERNATIONAL BUILDING CODE (IBC) – 2018 EDITION
• NFPA 101®, LIFE SAFETY CODE®(LSC) – 2018 EDITION
• OTHER RELEVANT NFPA CODES, AS APPLICABLE.
B (IBC 304.1) / BUSINESS (LSC 6.1.11.1) - ORDINARY HAZARD (LSC 39.1.5)
WET PIPE SPRINKLER SYSTEM (EXISTING)
FIRE ALARM & MASS NOTIFICATION SYSTEM (EXISTING)
ALLOWABLE HEIGHT
ACTUAL HEIGHT
UNLIMITED
3 STORIES
UNLIMITED
296,270
BUILDING ELEMENT
STRUCTURAL FRAME, INCLUDING COLUMNS, GIRDERS, TRUSSES
STRUCTURAL FRAME SUPPORTING A ROOF ONLY
BEARING WALLS, EXTERIOR
BEARING WALLS, INTERIOR
NON-BEARING WALLS, EXTERIOR
NON-BEARING WALLS, INTERIOR
FLOOR CONSTRUCTION, INCLUDING SUPPORTING BEAMS AND JOISTS
ROOF CONSTRUCTION, INCLUDING SUPPORTING BEAMS AND JOISTS
IBC TYPE IA
[TABLE 602]
1 1/2
FIRE SEPARATION DISTANCE (FSD)
FSD < 5 FT
5 FT ≤ FSD < 10 FT
FSD ≥ 10 FT
GROUP B
ALLOWABLE AREA (SF)
ACTUAL AREA (SF)
MINIMUMS BASED ON LSC TABLE A.10.2.2:
REQUIRED SEPARATION
1-HOUR (LSC 7.1.3.2.1)
SMOKE PARTITION (LSC 39.3.2)
SMOKE PARTITION (IBC 3104.5.2.1)
AREA
EXIT STAIR
MECH. ROOM
HORIZONTAL EXIT
EXITS
CLASS C
EXIT ACCESS
CORRIDORS
CLASS C
OTHER
CLASS C
OCCUPANCY
BUSINESS
AREA OCCUPANCY/USE
GROUP B/BUSINESS
GROUP A/ASSEMBLY
LEVEL TOTAL
GROUP B/BUSINESS
GROUP A/ASSEMBLY
LEVEL TOTAL
OVERALL TOTAL
APPROX.
AREA (SF)
144669 10037 154706
139388
141564 296270
OCCUPANT LOAD
FACTOR
(SF/PERSON)
OCCUPANT
LOAD
(PERSONS)
BASED ON LSC TABLE A.7.6:
ALL MEANS OF EGRESS SHALL BE ILLUMINATED IN ACCORDANCE WITH LSC 7.8 (LSC 39.2.8). ARTIFICIAL LIGHTING IS REQUIRED AT LOCATIONS
AND TIMES NECESSARY TO MAINTAIN ADEQUATE ILLUMINATION (LSC 7.8.1.2.1).
MEANS OF EGRESS SHALL BE PROVIDED WITH SIGNS IN ACCORDANCE WITH LSC 7.10 (LSC 38.2.10). SIGNS MUST HAVE LETTERING ON AN OPAQUE BACKGROUND. INTERNALLY ILLUMINATED SIGNS MUST BE LIGHT EMITTING DIODE (LED) TYPE, ELECTROLUMINESCENCE (LEC), OR COLD CATHODE TYPE. INCANDESCENT FIXTURES ARE NOT PERMITTED. RADIOLUMINOUS EXIT SIGNS ARE NOT PERMITTED
THE LOBBIES CONSIST OF MULTIPLE VERTICAL OPENINGS THAT CONNECT TWO FLOORS (FIRST AND SECOND FLOOR). THESE OPENINGS WITH
COMPLY WITH SECTION 8.6.9.1 OF THE LSC. THEY MEET THE FOLLOWING CRITERIA:
1. THESE OPENINGS CONNECT NOT MORE THAN TWO ADJACENT STORIES.
2. THESE OPENINGS ARE SEPARATED FROM UNPROTECTED VERTICAL OPENINGS SERVING OTHER FLOORS BY A BARRIER COMPLYING WITH 8.6.5
3. THESE OPENINGS ARE SEPARATEAD FROM CORRIDORS.
4. THESE OPENINGS ARE SEPARATED FROM OTHER FIRE OR SMOKE COMPARTMENTS ON THE SAME FLOOR.
5. THESE OPENINGS DO NOT SERVE AS A REQUIRED MEANS OF EGRESS.
REQUIRED EGRESS
CAPACITY
AVAILABLE EGRESS
CAPACITY
3,690
MEANS OF EGRESS
REQUIRED
MEANS OF EGRESS
PROVIDED
LOAD FACTORS (LSC TABLE 7.3.1.2):
ASSEMBLY USE (LESS CONCENTRATED USE, WITHOUT FIXED SEATING) 15-SF/PERSON (NET)
STORAGE USE (IN OTHER THAN STORAGE AND MERCANTILE OCCUPANCIES) 500-SF/PERSON
BUSINESS 150-SF/PERSON
TOTAL NUMBER OF OCCUPANTS IN THE BUILDING IS APPROXIMATED. OCCUPANT LOADS WERE CALCULATED USING THE SQUARE
FOOTAGE OF EACH FLOOR, NOT ON A ROOM-BY-ROOM BASIS.
FLOOR LEVEL
CAPACITY OF MEANS OF EGRESS (LSC TABLE 7.3.3.1):
LEVEL COMPONENTS (WIDTH/PERSON) 0.2 IN/PERSON
STAIRWAYS (WIDTH/PERSON) 0.3 IN/PERSON
MINIMUM NUMBER OF MEANS OF EGRESS (LSC 7.4): 4 FOR AN EXISTING BUSINESS OCCPANCY
FLOOR LEVEL
EXIT ACCESS
TRAVEL DISTANCE (FT)
COMMON PATH OF
TRAVEL (FT)
DEAD-END
CORRIDOR (FT)
OCCUPANCY
BUSINESS
ARRANGEMENT OF MEANS OF EGRESS
CAPACITY AND NUMBER OF MEANS OF EGRESS
ADDITIONAL LIFE SAFETY CRITERIA
VERTICAL OPENINGS
VEST
1199-10
1-M-10
1100-10 1000-10
1001-10
1-N-10
DN UP
LOBBY
STAIR
VEST
LOBBY
STAIR
ELEV
#5
ELEV
#6
ELEV
#9
ELEV
#10
ELEV
#7
ELEV
#8
ELEV
#11
ELEV
#12
BUILDING 9
BUILDING 9
BUILDING 9
BUILDING 9
BUILDING 9
B U
IL
D
IN
G
B U
IL
D
IN
G
UP
UP DN
KEY PLAN
Q
Q
PNM
J
J
H
H
G
G
F
F
E
B C D
D A
T E
A P
P R
D E
S C
R
IP
T
IO
N S
Y M
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
SCALE:
CONSTR. CONTR. NO.
EPROJECT NO.:
SHEET OF
NAVFAC DRAWING NO.
DES: DRW:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
DRAWFORM REVISION: 25 AUGUST 2020
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
W
A S
H
IN
G T
O N
P U
B L
IC
W O
R K
S D
E P
A R
T M
E N
T B
E T
H E
S D
A N
A V
A L
S U
P P
O R
T A
C T
IV
IT
Y B
E T
H E
S D
A M
A R
Y L
A N
D
CHK:
PM / DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
SATISFACTORY-TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
3200 LEE HIGHWAY, ARLINGTON, VA 22207
(703) 524 - 6616 www.mtfa.net
W A
LT
E
R R
E E
D N
A T
IO
N
A L
M
IL
IT
A
R Y
M E
D
IC
A L
C E
N T
E R
B E
T H
E S
D A
, M D
AS NOTED
1677850
FINAL DESIGN SUBMISSION
/1
/2
D
E S
IG
N
S U
B M
IS
S
IO
N
NTR AHE EHA
/2 /2
D
E S
IG
N
S U
B M
IS
S
IO
N
P R
E -F
IN
A
L D
E S
IG
N
S U
B M
IS
S
IO
N
/2 /2
F
IN
A L
D E
S
IG
N S
U B
M
IS
S
IO
N
/1 /2
/1
/2
:0
:4
P
M
E X
IS
T
IN
G
L
IF
E S
A F
E T
Y F
IR
S
T F
L O
O R
P L
A N
G101
B U
IL
D
IN
G
E
N T
R A
N C
E A
N D
C O
R R
ID
O
R M
O D
E R
N
IZ
A T
IO
N
13143615
G
P R
E -F
IN
A
L D
E S
IG
N
S U
B M
IS
S
IO
N
/2
/2
TRUE
NORTH
8' 16' 24' 32'
3/64" = 1'-0"
SCALE: G101 3/64" = 1'-0"
1 OVERALL LIFE SAFETY FIRST FLOOR PLAN - EXISTING
GENERAL NOTES
1. FIRE EXTINGUISHERS AND CABINETS
ARE EXISTING TO REMAIN UNLESS
OTHERWISE NOTED
KEYED NOTES
1. HORIZONTAL EXIT WITH SMOKE
PARTITION
CT030 C05P0
E
L
BUILDING 9
BUILDING 9
BUILDING 9 BUILDING 9
BUILDING 9
BUILDING 9
BUILDING 9
UP
DN
KEY PLAN
A Q
5 5
6 6
1 1
PNM
J
J
H
H
G
G
F
F
E
E
B C D
1 1
OPEN TO BELOWOPEN TO BELOW
OPEN TO
BELOW
OPEN TO BELOW
OPEN TO BELOW
OPEN TO BELOWOPEN TO BELOW
OPEN TO BELOW
OPEN TO BELOW
OPEN TO BELOW
D A
T E
A P
P R
D E
S C
R
IP
T
IO
N S
Y M
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
SCALE:
CONSTR. CONTR. NO.
EPROJECT NO.:
SHEET OF
NAVFAC DRAWING NO.
DES: DRW:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
DRAWFORM REVISION: 25 AUGUST 2020
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
W
A S
H
IN
G T
O N
P U
B L
IC
W O
R K
S D
E P
A R
T M
E N
T B
E T
H E
S D
A N
A V
A L
S U
P P
O R
T A
C T
IV
IT
Y B
E T
H E
S D
A M
A R
Y L
A N
D
CHK:
PM / DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
SATISFACTORY-TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
3200 LEE HIGHWAY, ARLINGTON, VA 22207
(703) 524 - 6616 www.mtfa.net
W A
LT
E
R R
E E
D N
A T
IO
N
A L
M
IL
IT
A
R Y
M E
D
IC
A L
C E
N T
E R
B E
T H
E S
D A
, M D
AS NOTED
1677850
FINAL DESIGN SUBMISSION
/1
/2
D
E S
IG
N
S U
B M
IS
S
IO
N
NTR AHE EHA
/2 /2
D
E S
IG
N
S U
B M
IS
S
IO
N
P R
E -F
IN
A
L D
E S
IG
N
S U
B M
IS
S
IO
N
/2 /2
F
IN
A L
D E
S
IG
N S
U B
M
IS
S
IO
N
/1 /2
/1
/2
:0
:5
P
M
E X
IS
T
IN
G
L
IF
E S
A F
E T
Y S
E C
O N
D F
L O
O R
P L
A N
GI102
B U
IL
D
IN
G
E
N T
R A
N C
E A
N D
C O
R R
ID
O
R M
O D
E R
N
IZ
A T
IO
N
13143616
G I1
P R
E -F
IN
A
L D
E S
IG
N
S U
B M
IS
S
IO
N
/2
/2
TRUE
NORTH
8' 16' 24' 32'
3/64" = 1'-0"
SCALE: GI102 3/64" = 1'-0"
1 OVERALL LIFE SAFETY SECOND FLOOR PLAN - EXISTING
GENERAL NOTES
1. FIRE EXTINGUISHERS AND CABINETS
ARE EXISTING TO REMAIN UNLESS
OTHERWISE NOTED
KEYED NOTES
1. HORIZONTAL EXIT WITH SMOKE
PARTITION
2. EXISTING ESCALATOR TO BE REMOVED.
VEST
1199-10
1-M-10
1000-10
1001-10
1-N-10
DN UP
STAIR
VEST
LOBBY
STAIR
ELEV
#9
ELEV
#10
ELEV
#7
ELEV
#8
ELEV
#11
ELEV
#12
UP
UP DN
Q
Q
P
P
N
N
M
M
L
L
K
K
J
J
H
H
G
G
F
F
E
E
B
B
C
C
D
D Q
PNM
J
J
H
H
G
G
F
F
E
B C D
CPT = 54 FT
TD
2 F
T
1 1
KEY PLAN
D A
T E
A P
P R
D E
S C
R
IP
T
IO
N S
Y M
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
SCALE:
CONSTR. CONTR. NO.
EPROJECT NO.:
SHEET OF
NAVFAC DRAWING NO.
DES: DRW:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
DRAWFORM REVISION: 25 AUGUST 2020
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
W
A S
H
IN
G T
O N
P U
B L
IC
W O
R K
S D
E P
A R
T M
E N
T B
E T
H E
S D
A N
A V
A L
S U
P P
O R
T A
C T
IV
IT
Y B
E T
H E
S D
A M
A R
Y L
A N
D
CHK:
PM / DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
SATISFACTORY-TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
3200 LEE HIGHWAY, ARLINGTON, VA 22207
(703) 524 - 6616 www.mtfa.net
W A
LT
E
R R
E E
D N
A T
IO
N
A L
M
IL
IT
A
R Y
M E
D
IC
A L
C E
N T
E R
B E
T H
E S
D A
, M D
AS NOTED
1677850
FINAL DESIGN SUBMISSION
/1
/2
D
E S
IG
N
S U
B M
IS
S
IO
N
NTR AHE EHA
/2 /2
D
E S
IG
N
S U
B M
IS
S
IO
N
P R
E -F
IN
A
L D
E S
IG
N
S U
B M
IS
S
IO
N
/2 /2
F
IN
A L
D E
S
IG
N S
U B
M
IS
S
IO
N
/1 /2
/1
/2
:0
:5
P
M
N E
W L
IF
E
S A
F E
T Y
F
IR
S T
F L
O O
R P
L A
N
GI103
B U
IL
D
IN
G
E
N T
R A
N C
E A
N D
C O
R R
ID
O
R M
O D
E R
N
IZ
A T
IO
N
13143617
G I1
P R
E -F
IN
A
L D
E S
IG
N
S U
B M
IS
S
IO
N
/2
/2
SCALE: GI103 3/64" = 1'-0"
1 OVERALL LIFE SAFETY FIRST FLOOR PLAN - NEW
GENERAL NOTES
1. FIRE EXTINGUISHERS AND CABINETS
ARE EXISTING TO REMAIN UNLESS
OTHERWISE NOTED
KEYED NOTES
1. HORIZONTAL EXIT WITH SMOKE PARTITION
2. NEW FIRE EXTINGUISHER AND CABINET
3. NEW 2 HOUR SMOKE BARRIER
4. REVISED ENTRANCE/EXIT CONFIGURATION
TRUE
NORTH
8' 16' 24' 32'
3/64" = 1'-0"
CT030 C05P0
E
L
UP
DN
4 4
Q
Q
5 5
6 6
1 1
P
P
N
N
M
M
L
L
K
K
J
J
H
H
G
G
F
F
E
E
B
B
C
C
D
D
OPEN TO BELOW
OPEN TO BELOW
OPEN TO BELOWOPEN TO BELOW
OPEN TO BELOW
OPEN TO BELOW
OPEN TO BELOW
OPEN TO BELOW
OPEN TO
BELOW OPEN TO BELOW
PLASTIC &
RECONSTRUCTIVE
SURGERY
HOSPITAL
DENTISTRY
ORAL &
MAXILLOFACIAL
SURGERY
SLEEP
DISORDER
CENTER
Q
5 5
6 6
1 1
PNM
J
J
H
H
G
G
F
F
E
E
B C D
1 1
KEY PLAN
D A
T E
A P
P R
D E
S C
R
IP
T
IO
N S
Y M
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
SCALE:
CONSTR. CONTR. NO.
EPROJECT NO.:
SHEET OF
NAVFAC DRAWING NO.
DES: DRW:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
DRAWFORM REVISION: 25 AUGUST 2020
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
W
A S
H
IN
G T
O N
P U
B L
IC
W O
R K
S D
E P
A R
T M
E N
T B
E T
H E
S D
A N
A V
A L
S U
P P
O R
T A
C T
IV
IT
Y B
E T
H E
S D
A M
A R
Y L
A N
D
CHK:
PM / DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
SATISFACTORY-TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
3200 LEE HIGHWAY, ARLINGTON, VA 22207
(703) 524 - 6616 www.mtfa.net
W A
LT
E
R R
E E
D N
A T
IO
N
A L
M
IL
IT
A
R Y
M E
D
IC
A L
C E
N T
E R
B E
T H
E S
D A
, M D
AS NOTED
1677850
FINAL DESIGN SUBMISSION
/1
/2
D
E S
IG
N
S U
B M
IS
S
IO
N
NTR AHE EHA
/2 /2
D
E S
IG
N
S U
B M
IS
S
IO
N
P R
E -F
IN
A
L D
E S
IG
N
S U
B M
IS
S
IO
N
/2 /2
F
IN
A L
D E
S
IG
N S
U B
M
IS
S
IO
N
/1 /2
/1
/2
:0
:5
P
M
N E
W L
IF
E
S A
F E
T Y
F L
O O
R P
L A
N
GI104
B U
IL
D
IN
G
E
N T
R A
N C
E A
N D
C O
R R
ID
O
R M
O D
E R
N
IZ
A T
IO
N
13143618
G I1
P R
E -F
IN
A
L D
E S
IG
N
S U
B M
IS
S
IO
N
/2
/2
SCALE: GI104 3/64" = 1'-0"
1 OVERALL LIFE SAFETY SECOND FLOOR PLAN - NEW
GENERAL NOTES
1. FIRE EXTINGUISHERS AND CABINETS
ARE EXISTING TO REMAIN UNLESS
OTHERWISE NOTED
KEYED NOTES
1. HORIZONTAL EXIT WITH SMOKE
PARTITION
2. NEW STAIR. NOT USED FOR EGRESS.
SEE ARCHITECTURAL PLAN FOR DETAILS
DESIGN NOTES
I. CODES AND STANDARDS
A. WORK MUST BE IN ACCORDANCE WITH REQUIREMENTS OF THE FOLLOWING CODES
AND STANDARDS:
1. THE INTERNATIONAL BUILDING CODE, 2018, INTERNATIONAL CODE COUNCIL
2. FC 1-300-09N DESIGN PROCEDURES
3. UFC 1-200-01 DOD BUILDING CODE
4. UFC 3-301-01 STRUCTURAL ENGINEERING
5. UFC 4-010-01 DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS
6. UFC 4-020-01 DOD SECURITY ENGINEERING FACILITIES PLANNING MANUAL
7. UFC 4-510-01 DESIGN: MILITARY MEDICAL FACILITIES
8. ASCE 7-16, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES
II. DESIGN AND LOADING CRITERIA
A. ALL CODES, REFERENCES AND STANDARDS REFERRED TO MUST BE THE CURRENT
VERSION UNLESS A DIFFERENT VERSION IS LISTED IN THE BUILDING CODE.
B. SNOW LOAD
1. GROUND SNOW LOAD: (PG) = 25 PSF
2. SNOW EXPOSURE FACTOR (CE): = 1.0
3. IMPORTANCE FACTOR (I): = 1.2
4. THERMAL FACTOR (CT): = 1.0
5. FLAT ROOF SNOW LOAD (PF): = 21 PSF
C. SEISMIC LOAD
1. RISK CATEGORY: = IV
2. SEISMIC IMPORTANCE FACTOR (I): = 1.5
3. MAPPED SPECTRAL RESPONSE: SS = 0.134g, S1= 0.043g
4. SPECTRAL RESPONSE COEFF SDS = 0.116, SD1= 0.043
5. SITE CLASSIFICATION: = C
6. SEISMIC DESIGN CATEGORY: = A
D. WIND LOAD (GOVERNS)
1. ULTIMATE DESIGN WIND SPEED: = 125 MPH
2. RISK CATEGORY: = IV
3. EXPOSURE: = B
4. INTERNAL PRESSURE COEFF: = +/- 0.18
5. COMPONENT AND CLADDING:
FOR WALL = 69 PSF MAX
OTHER DESIGN PRESSURES MAYBE USED IF SIGNED & SEALED CALCULATIONS
ARE SUBMITTED FOR REVIEW
E. FLOOR DESIGN MINIMUM LIVE LOADS:
1. ASSEMBLY (LOBBY) = 100 PSF
2. STAIR = 100 PSF
3. INFORMATION DESK AREA = 60 PSF
4. 2ND FLOOR = 80 PSF
F. EXISTING LIVE LOAD CAPACITIES
1. THE EXISTING ALLOWABLE LIVE LOAD CAPACITIES ARE AS FOLLOWS: LOBBY = 100 PSF.
2. TEMPORARY SHORING AND/OR BRACING MUST BE PROVIDED WHEREVER THE
LOADING FROM THE CONTRACTOR’S WORK EXCEEDS THE ALLOWABLE LOAD
CAPACITIES OF THE EXISTING STRUCTURE.
III. CONCRETE AND REINFORCING
A. CONCRETE WORK MUST BE IN ACCORDANCE WITH "BUILDING CODE REQUIREMENTS FOR
STRUCTURAL CONCRETE", ACI 318. AS MODIFIED BY IBC CODE.
B. CONCRETE DESIGN IS IN ACCORDANCE WITH "STRENGTH DESIGN METHOD."
C. ULTIMATE COMPRESSIVE STRENGTH OF CONCRETE AT 28 DAYS (F'C) ELSEWHERE MUST BE:
1. FIRST AND SECOND FLOOR SLABS ON DECK: = 3,500 PSI LIGHTWEIGHT
D. CONCRETE MATERIALS:
1. CEMENT: ASTM C-150 TYPE I OR III
2. CEMENT SUBSTITUTES: ASTM C-595 TYPE '1P' (LIMIT TO 25% MAXIMUM
CEMENTITIOUS CONTENT BY WEIGHT.)
3. AGGREGATES: ASTM C-33 (NORMAL WEIGHT)
ASTM C-330 (STRUCTURAL LIGHTWEIGHT)
4. AIR-ENTRAINING ADMIX: ASTM C-260
5. ISOLATION JOINT FILLER: ASTM D-1751
6. JOINT SEALANT: ASTM C-920
E. CONCRETE EXPOSED TO WEATHER MUST BE AIR-ENTRAINED 6%, +/- 1%.
F. CONCRETE MUST BE THOROUGHLY COMPACTED DURING PLACEMENT AND WORKED
AROUND EMBEDDED ITEMS AND INTO CORNERS OF FORMS.
G. CONTRACTOR MUST BE RESPONSIBLE FOR ALL ITEMS EMBEDDED IN CONCRETE AND
MUST ENSURE THAT ALL ARE ACCURATELY LOCATED AND SECURE.
H. DEPRESSIONS MUST BE LOCATED FROM ARCHITECTURAL PLANS. PENETRATIONS FOR
MECHANICAL, PLUMBING AND ELECTRICAL WORK MUST BE COORDINATED WITH
MECHANICAL,PLUMBING AND ELECTRICAL ENGINEERING AND ARCHITECTURAL
DRAWINGS. WHERE NOT INDICATED ON STRUCTURAL PLANS, SLAB PENETRATIONS MUST BE
MADE NO CLOSER THAN 2'-0" TO COLUMN FACE IN FLAT-SLAB CONSTRUCTION.
I. CONTRACTOR MUST SUBMIT PROPOSED CONTRACTION JOINT LAYOUT DRAWING FOR
REVIEW. PRIOR TO POURING SLAB.
J. EXPOSED CONCRETE WALLS MUST HAVE CONTROL JOINTS AT 20 FEET ON CENTERS
EQUALLY SPACED AS INDICATED.
K. CONCRETE SLUMP MUST = 4" PLUS OR MINUS 1".
L. PROVIDE KEYED JOINTS BETWEEN ALL NON-MONOLITHIC INTERSECTING CONCRETE WALLS
AND ALL CONCRETE JOINTS.
M. GROUT MUST BE NON-SHRINKABLE, NON-METALLIC CONFORMING TO ASTM C1107, AND
MUST HAVE A SPECIFIED COMPRESSIVE STRENGTH AT 28 DAYS OF 7,000 PSI.
PREGROUTING OF BASE PLATES MUST NOT BE PERMITTED.
N. FORM CONTRACTION JOINTS WITH AN EARLY ENTRY DRY-CUT SAW EQUIPPED WITH
SHATTERPROOF ABRASIVE OR DIAMOND-RIMMED BLADES. CUT 1/8-INCH WIDE JOINTS INTO
CONCRETE WHEN CUTTING ACTION WILL NOT TEAR, ABRADE, OR OTHERWISE DAMAGE
SURFACE AND BEFORE CONCRETE DEVELOPS RANDOM CONTRACTION CRACKS, BUT IN NO
CASE LATER THAN 4 HOURS AFTER START OF POUR.
O. SUBMIT SHOP DRAWINGS FOR REINFORCEMENT TO THE CONTRACTING OFFICER FOR
APPROVAL. PREPARE DRAWINGS UNDER THE SUPERVISION OF A PROFESSIONAL
STRUCTURAL ENGINEER REGISTERED IN THE LOCAL JURISDICTION DETAILING
FABRICATING, BENDING, AND PLACING CONCRETE REINFORCEMENT. COMPLY WITH ACI 315
AND ACI DETAILING MANUAL SP-66, SHOWING BAR SCHEDULES, STIRRUP SPACING, BENT
BAR DIAGRAMS, AND ARRANGEMENT OF CONCRETE REINFORCEMENT. INCLUDE SPECIAL
REINFORCING REQUIRED FOR OPENINGS THROUGH CONCRETE STRUCTURES.
P. REINFORCING BARS #3 THRU #11 MUST BE DEFORMED AND IN ACCORDANCE WITH
"SPECIFICATIONS FOR DEFORMED AND PLAIN BILLET STEEL BARS FOR CONCRETE
REINFORCEMENT" ASTM A-615. GRADE 60 KSI
Q. WELDED WIRE FABRIC NOTED "WWF" MUST BE IN ACCORDANCE WITH "STANDARD
SPECIFICATION FOR STEEL WELDED WIRE REINFORCEMENT, PLAIN, FOR CONCRETE" ASTM
A-1064. WHERE INDICATED, EPOXY COAT WWF IN ACCORDANCE WITH ASTM A-884.
R. BARS MARKED CONTINUOUS (CONT) MUST BE LAPPED IN ACCORDANCE WITH
REQUIREMENTS FOR SPLICES AS DEFINED IN ACI 318, MINIMUM 50 BAR DIAMETERS,
UNLESS INDICATED OTHERWISE. COLUMN VERTICAL REINFORCING MUST BE SPLICED AS
SHOWN IN COLUMN DETAILS.
S. BAR LENGTHS SHOWN ON PLAN DO NOT INCLUDE LENGTH OF HOOK WHERE A HOOK IS
INDICATED. PROVIDE STANDARD HOOK UNLESS DETAILED OTHERWISE.
T. MINIMUM CONCRETE COVER BETWEEN FACE OF REINFORCING BAR AND FACE OF
CONCRETE MUST BE AS FOLLOWS:
1. FORMED CONCRETE NOT EXPOSED TO WEATHER:
a) SLABS = 1"
IV. STRUCTURAL STEEL
A. STRUCTURAL STEEL MUST BE DESIGNED, FABRICATED AND ERECTED IN
ACCORDANCE WITH "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS AND THE
"MANUAL OF STEEL CONSTRUCTION" FIFTEEN EDITION.
B. STRUCTURAL STEEL:
1. STRUCTURAL "W" & "T" SHAPES: ASTM A-992 FY = 50,000 PSI U.N.O.
2. BALANCE OF STRUCTURAL STEEL SHAPES & PLATES: ASTM A-36 FY = 36,000 PSI
3. HOLLOW STRUCTURAL SECTIONS ASTM A-500B FY=46,000 PSI
SQUARE & RECTANGULAR
4. HIGH STRENGTH BOLTS: ASTM A-325 CONN TYPE N
5. SMOOTH, THREADED ROD: ASTM A-36
6. SHEAR CONNECTORS: ASTM A-108, GRADES 1015 THRU
1020, HEADED STUD TYPE.
C. CONNECTIONS MUST BE DESIGNED IN ACCORDANCE WITH "BEAM CONNECTIONS" AS
DESCRIBED IN THE AISC MANUAL. CONNECTIONS MUST BE MADE USING HIGH STRENGTH
BOLTS IN ACCORDANCE WITH ASTM A-325. SHOP CONNECTIONS MAY BE WELDED IN LIEU
OF BOLTING. WHERE REACTION NOT GIVEN ON PLANS AND SECTIONS CONNECTIONS MUST
BE DESIGNED FOR A MINIMUM OF 60% FOR FILLER BEAMS AND 70 % FOR GIRDERS OF
MAXIMUM BEAM CARRYING CAPACITY UNDER UNIFORM LOAD FOR SPAN SHOWN. SEE
PLANS AND SECTIONS FOR OTHER THAN STANDARD CONNECTIONS. MINIMUM NUMBER OF
BOLTS IN EACH OF BEAM WEB CONNECTION AND TO SUPPORTING MEMBER MUST BE AS
FOLLOWS:
(SECTIONS; MC, C, S, M & WF)
D = 4" - 6": 2 BOLTS HORIZONTAL
D = 8" - 10": 2 BOLTS VERTICAL
D = 12" - 15": 3 BOLTS VERTICAL
D = 16" - 21": 4 BOLTS VERTICAL
D = 24" 5 BOLTS VERTICAL
BOLT SPACING MUST BE 3" O/C.
D. ALTERNATE CONNECTIONS TO THOSE SHOWN ON PLANS AND DETAILS WILL BE ALLOWED
ONLY WITH THE APPROVAL OF THE CONTRACTING OFFICER. IF SUCH APPROVAL IS
GRANTED, CONNECTIONS, ETC. NOT IN ACCORDANCE WITH CONTRACT DOCUMENTS
(FABRICATOR'S REDESIGN) MUST BE SUBMITTED WITH SHOP DRAWINGS UNDER THE SEAL
OF LICENSURE OF THE FABRICATOR'S ENGINEER FOR THE LOCAL JURISDICTION.
E. UNLESS OTHERWISE NOTED, A-325 BOLTS MUST BE TIGHTENED TO THE "SNUG TIGHT"
CONDITION DEFINED AS THE TIGHTNESS ATTAINED BY A FEW IMPACTS OF AN IMPACT
WRENCH OR THE FULL EFFORT OF A MAN USING AN ORDINARY SPUD WRENCH. THE SNUG-
TIGHT CONDITION MUST ENSURE THAT THE PLIES OF THE CONNECTED MATERIAL HAVE
BEEN BROUGHT INTO FIRM CONTACT.
F. WELDING MUST CONFORM TO REQUIREMENTS OF THE "STRUCTURAL WELDING CODE"
AWS D1.1-08. USE 70 KSI LOW-HYDROGEN ELECTRODES.
G. GROUT UNDER COLUMN BASE PLATES MUST BE NON-SHRINK, NON-METALLIC AND HAVE A
MINIMUM 28 DAY COMPRESSIVE STRENGTH F'C = 7000 PSI.
H. UNLESS GALVANIZED OR TO RECEIVE SPRAY-APPLIED FIREPROOFING, STRUCTURAL STEEL
MUST RECEIVE ONE SHOP COAT AND ONE FIELD TOUCH-UP COAT OF RUST-INHIBITING
PAINT AFTER ERECTION.
I. NO FABRICATION MUST PROCEED PRIOR TO SHOP DRAWINGS APPROVAL.
J. NO OPENINGS IN BEAMS OR COLUMNS ARE PERMITTED WITHOUT THE APPROVAL OF THE
CONTRACTING OFFICER.
K. SPLICING OF STRUCTURAL STEEL MEMBERS WHERE NOT DETAILED ON THE CONTRACT
DOCUMENTS IS PROHIBITED WITHOUT PRIOR APPROVAL OF THE CONTRACTING OFFICER
AS TO LOCATION, TYPE OF SPLICE AND CONNECTION TO BE MADE.
L. DEVELOPMENT OF STRUCTURAL STEEL SHOP DRAWINGS MUST BE SUPERVISED BY A
REGISTERED PROFESSIONAL ENGINEER REGISTERED IN PROJECT JURISDICTION AND MUST
INCLUDE DETAILS FOR APPLICATION AND ASSEMBLY OF ALL STRUCTURAL MEMBERS.
INCLUDE DETAILS OF CUTS, CONNECTIONS, HOLES, AND OTHER PERTINENT DATA.
INDICATE WELDS BY STANDARD AWS 2.1 SYMBOLS SHOWING SIZE, LENGTH AND TYPE OF
EACH WELD. SHOP DRAWINGS MUST BE SUBMITTED TO THE CONTRACTING OFFICER FOR
APPROVAL.
M. ALL MISCELLANEOUS STEEL CONNECTIONS MUST BE WELDED ALL AROUND WITH ONE-
QUARTER-INCH FILLET WELD UNLESS OTHERWISE NOTED, EXCEPT FOR SLOTTED
CONNECTIONS.
N. HANDRAILS, GUARDRAILS AND LADDERS MUST BE DESIGNED BY THE MANUFACTURER'S
ENGINEER FOR THE MOST RESTRICTIVE OF THE LOADS GIVEN AND APPLICABLE DESIGN
CODE. IN NO CASE MUST TOTAL COMBINED POST/RAILING DEFLECTION EXCEED 0.75", THE
LIMITS IN ASTM E985 OR LIMITATION OF MATERIAL USED AS INFILL, WHICHEVER IS MORE
RESTRICTIVE. SUBMIT SHOP DRAWINGS BEARING THE SEAL OF A PROFESSIONAL ENGINEER
REGISTERED IN THE PROJECT JURISDICTION TO THE CONTRACTING OFFICER INDICATING
ALL MEMBERS AND CONNECTIONS.
O. FULL PENETRATION WELDS MUST BE MADE AGAINST A 1/8" X 1" BACKER PLATE TACK
WELDED IN PLACE BELOW THE WELD. PENETRATION WELDS MUST BE EQUIVALENT IN
DEPTH AND LENGTH TO THE PARTS JOINED.
P. CONTRACTOR MUST NOT RELEASE BEAMS OR DIAGONAL BRACING FROM HOISTING
CABLES UNTIL ALL MEMBERS ARE SECURE WITH AT LEAST (2) BOLTS. ALL FIELD WELDED
CONNECTIONS MUST BE COMPLETED BEFORE RELEASING CABLES.
Q. WHERE DOUBLE BEAM CONNECTIONS OCCUR ON EACH SIDE OF A COLUMN WEB OR TO
THE WEB OF A BEAM OVER A COLUMN, THERE MUST BE AT LEAST ONE BOLT WITH A
WRENCH-TIGHT NUT SECURING THE FIRST BEAM CONNECTED AT ALL TIMES.
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
W A
S H
IN
G
T O
N N
A V
A L
S U
P P
O R
T A
C T
IV
IT
Y B
E T
H E
S D
A M
A R
Y L
A N
D
AS NOTED
P U
B L
IC
W
O R
K S
D E
P A
R T
M E
N T
B
E T
H E
S D
A
11800 SUNRISE VALLEY DR, STE 430
RESTON, VA 20191
(703) 556 - 0651 www.mcmse.com
PROFESSIONAL CERTIFICATION. I CERTIFY THAT
THESE DOCUMENTS WERE PREPARED OR
APPROVED BY ME AND THAT I AM A DULY
LICENSED ENGINEER UNDER THE LAWS OF THE
STATE OF MARYLAND, LICENSE NUMBER 32719,
EXPIRATION DATE 2/9/2024.
/9
/2
:4
:0
P M
S-001
B U
IL
D
IN
G
E
N T
R A
N C
E A
N D
C O
R R
ID
O
R
M O
D E
R N
IZ
A
T
IO
N
D E
S
IG
N N
O
TE
S
DBSCP CK
B E
T H
E S
D A
M
D W
A L T
E R
R E
E D
N A
T
IO
N A
L M
IL
IT
A R
Y M
E D
IC
A
L C
E N
T E
R
S -0
F
IN
A
L D
E S
IG
N
S U
B M
IS
S
IO
N
/1
/2
/1
/2
F
IN
A L D
E S
IG
N
S U
B M
IS
S
IO
N
FINAL DESIGN SUBMISSION
8 162 13143619
1677850
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P
May 17, 2022
V. STEEL DECKING
A. PROVIDE MATERIALS, DESIGN AND INSTALLATION OF DECK FOR THE REQUIREMENTS OF STEEL
DECK INSTITUTE'S "DESIGN MANUAL FOR COMPOSITE DECKS, FORM DECKS AND ROOF DECKS."
DECK PROPERTIES MUST BE COMPUTED USING THE LATEST EDITION OF AISI SPECIFICATION
FOR THE "DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS."
B. PROVIDE GALVANIZED STEEL ROOF DECKING CONFORMING TO ASTM A653 WITH MINIMUM
YIELD STRESS = 33 KSI. GALVANIZING MUST CONFORM TO ASTM A924 COATING CLASS G60.
PROVIDE DECK DEPTH AND GAUGE AS INDICATED ON PLANS.
C. PROVIDE GALVANIZED COMPOSITE STEEL FLOOR DECKING. GALVANIZE STEEL SHEET IN
ACCORDANCE WITH ASTM A653 GRADE 33 WITH G90 GALVANIZED COATING. PROVIDE DECK
DEPTH AND GAUGE AS INDICATED ON PLANS.
D. ALL 1 1/2 INCH DECKING SHALL BE WELDED TO STRUCTURAL STEEL MEMBERS WITH 5/8" PUDDLE WELDS TO ACHIEVE A 36/4 LAYOUT. SIDE LAPS FOR METAL DECK DIAPHRAGM SHALL BE 5 #10 TEK
SCREWS PER SPAN.
E. ALL 3 INCH DECKING MUST BE WELDED TO STRUCTURAL STEEL MEMBERS WITH 5/8" PUDDLE
WELDS TO ACHIEVE A SELECT LAYOUT 24/4 LAYOUT. SIDE LAPS FOR METAL DECK
DIAPHRAGM MUST BE SELECT NUMBER 9#10 TEK SCREWS PER SPAN.
F. PROVIDE IN ALL CONCRETE FILL ON METAL DECK WITH WELDED WIRE FABRIC WWF 6x6 - W2.9 x W2.9 STEEL DECK MUST BE INSTALLED CONTINUOUS MORE THAN 2 SPANS MINIMUM (U.N.O.) AND
MUST BEAR AT LEAST 2" ON STEEL ON STEEL SUPPORTS.
G. DO NOT EMBED CONDUIT IN CONCRETE FILL ON METAL DECK.
H. PROVIDE CONTINUOUS CLOSURES AND POUR STOPS AT DECK ENDS, EDGES AND OPENINGS
WHERE NO STEEL ANGLE IS SPECIFIED.
I PROVIDE SUPPLEMENTAL FRAMING (L4 X 4 X 3/8, OR TS 2 1/2 X 2 1/2 X ¼) AS NECESSARY FOR THE
SUPPORT OF METAL DECK WHERE NOT SHOWN ON DRAWINGS, UNLESS OTHERWISE
INDICATED.
J. PROVIDE ADDITIONAL CONCRETE, WHICH MAY BE REQUIRED AS A RESULT OF DEFLECTION OF
THE FLOOR BEAMS AND DECK DURING PLACEMENT OF CONCRETE.
K. FABRICATE SUPPORTS FOR DECK SO THAT THE DECK RUNS CONTINUOUSLY OVER THE OPENING.
DECK MUST BE CUT FROM THE OPENING IMMEDIATELY PRIOR TO PLACING THE EQUIPMENT
OVER THE OPENING OR WALLS AROUND THE SHAFT EXCEPT WHERE CONCRETE FILL IS
PROVIDED.
VI. GENERAL
A. INFORMATION SHOWN REGARDING EXISTING CONDITIONS HAS BEEN OBTAINED BY LIMITED
VISUAL OBSERVATIONS AND FROM EXISTING DRAWINGS BY DALTON DALTON LITTLE NEWPORT
DATED 2/17/1976 PROVIDED BY THE AUTHORITY HAVING JURISDICTION. AREAS NOT VISIBLE
HAVE BEEN ASSUMED TYPICAL WITH OBSERVED EXISTING CONDITIONS.
B. MEASURE AND PROVIDE ALL DIMENSIONS, ELEVATIONS AND CONDITIONS AT THE JOB SITE
PRIOR TO CONSTRUCTION AND THE SUBMISSION OF SHOP DRAWINGS, AND NOTIFY THE
CONTRACTING OFFICER IMMEDIATELY OF ANY DISCREPANCIES. VERIFICATION AND
NOTIFICATION MUST PROCEED TWO WEEKS PRIOR TO THE START OF WORK SO THAT ANY
NECESSARY CHANGES CAN BE MADE WITHOUT DELAYING THE PROJECT SCHEDULE.
C. DETAILS, SECTIONS, AND NOTES SHOWN ON THESE DRAWINGS ARE INTENDED TO BE TYPICAL
AND MUST APPLY TO SIMILAR CONDITIONS ELSEWHERE UNLESS OTHERWISE SHOWN OR
NOTED.
D. SHOP DRAWINGS SUBMITTED TO THE CONTRACTING OFFICER MUST BEAR THE CONTRACTOR'S
STAMP, DATE AND SIGNATURE VERIFYING DOCUMENTS HAVE BEEN REVIEWED AND
CORRECTED FOR CONFORMANCE TO AND COORDINATION WITH CONTRACT DOCUMENTS.
E. FABRICATION MUST PROCEED ONLY AFTER SHOP DRAWING APPROVAL BY THE ENGINEER.
F. DO NOT REPRODUCE ANY PORTION OF CONTRACT DOCUMENTS IN THE SHOP DRAWINGS.
G. INSPECTION REPORTS AND MATERIALS TESTING REPORTS MUST BE SUBMITTED TO THE
ENGINEER IN A TIMELY MANNER SUCH THAT CONSTRUCTION DELAY WILL BE AVOIDED.
H. MEANS AND METHODS OF CONSTRUCTION ARE THE SOLE RESPONSIBILITY OF THE
CONTRACTOR.
I. WHERE THE CONTRACTOR IS REQUIRED TO ENGAGE A PROFESSIONAL ENGINEER TO DESIGN
AND SUBMIT CALCULATIONS, AND WHERE THE PROFESSIONAL ENGINEER PREPARES THE
CALCULATIONS USING A COMPUTER SOFTWARE SYSTEM, THE SOFTWARE MUST BE A READILY
AVAILABLE, INDUSTRY STANDARD STRUCTURAL ENGINEERING COMMERCIAL SYSTEM IN
COMMON USE.
VII. TESTING AND INSPECTION
THE CONTRACTOR MUST RETAIN THE SERVICES OF A TESTING AND INSPECTION AGENCY TO PERFORM
THE SERVICES SPECIFIED.
A. MINIMUM SERVICES PROVIDED MUST BE IN ACCORDANCE WITH REQUIREMENTS OF THE LOCAL
JURISDICTION.
B. FAILURE TO RETAIN A TESTING AGENCY TO PROVIDE REQUIRED SERVICES OR A FAILURE TO SUBMIT
SIGNED AND SEALED REPORTS MUST BE CONSIDERED NON-COMPLIANCE WITH CONTRACT
DOCUMENTS.
C. CONSTRUCTION CONSIDERED NON-COMPLIANT MUST BE REMOVED AND REPLACED.
D. ALL TESTING AND INSPECTION MUST BE UNDER THE DIRECTION OF A PROFESSIONAL ENGINEER
LICENSED TO PRACTICE IN THE LOCAL JURISDICTION.
E. PRELIMINARY HAND WRITTEN SITE VISIT REPORTS CONFIRMING VERBAL DISCUSSIONS MUST BE
PROVIDED TO THE CONTRACTOR ON RESULTS OF INSPECTIONS PRIOR TO LEAVING JOB SITE.
F. FINAL REPORTS MUST BE SUBMITTED TO THE CONTRACTING OFFICER IN A TIMELY MANNER, BUT NO
LATER THAN TEN (10) DAYS FOLLOWING INSPECTION OR TESTING. UNDER THE NAME AND
SIGNATURE OF THE INSPECTOR AND LICENSURE SEAL AND SIGNATURE OF THE PROFESSIONAL
ENGINEER RESPONSIBLE FOR TESTING AND INSPECTION.
G. INSPECTION MUST MINIMALLY INCLUDE THE FOLLOWING:
1. REINFORCING: LOCATION, ASTM DESIGNATION, BAR SIZES, TYPE (PLAIN OR EPOXY COATED), QUANTITY, PLACEMENT, SPACING, AND CLEARANCES.
2. CONCRETE: ALL STRUCTURAL CONCRETE; LOCATION, STRENGTH, TYPE (NORMAL OR
LIGHTWEIGHT), SLUMP, PLACEMENT, AIR TEMPERATURE, CURING AND WEATHER
ACCOMMODATIONS AND CONCRETE ADDITIVES.
3. STRUCTURAL STEEL: LOCATION, ASTM DESIGNATION, MEMBER SIZES, TYPE (PLAIN, PAINTED, GALVANIZED, STAINLESS), PLACEMENT AND CONNECTIONS INCLUDING WELDS AND BOLTS, STUDS IN COMPOSITE CONSTRUCTION, POST INSTALLED ANCHORS, ANCHOR BOLTS AND
GROUTING.
H. MATERIAL TESTING MUST MINIMALLY INCLUDE THE FOLLOWING:
1. REINFORCING: YIELD AND ULTIMATE STRENGTHS. (MILL REPORTS ARE ACCEPTABLE.)
2. CONCRETE: SLUMP TESTS; EVERY THIRD TRUCKLOAD OF CONCRETE AND IN ADDITION, ONE FOR
EACH SET OF STRENGTH-TEST CYLINDERS AT PREPARATION. STRENGTH TESTS; ONE SET OF
CYLINDERS FOR MAXIMUM OF EACH 50 CY OF CONCRETE PLACEMENT. ONE SET OF CYLINDERS
FOR EACH 2500 SQUARE SLAB AREA.
3. STRUCTURAL STEEL: YIELD AND ULTIMATE STRENGTHS. (MILL REPORTS ARE ACCEPTABLE.)
I. COMPLY WITH CODE REQUIREMENTS AND THE FOLLOWING:
1. CONCRETE CYLINDERS: ONE SET OF 8 LABORATORY CURED 4x8 CYLINDERS MUST BE TAKEN
FOR EACH DAY'S POUR FOR EACH MIX: (3) 7-DAY, (3) 28-DAY, (2) HOLD;
2. ONE SET OF 6 FIELD CURED 4x8 CYLINDERS MUST BE TAKEN FOR EACH DAY’S POUR FOR EACH
MIX (3) 7 –DAY, (3)…