Attach V - Communications Suite Technical Exhibits (TE) 1-4 - Amend 2.PDF

PDF 279 KB Posted

Attached to
Operation and Maintenance of Maritime Prepositioning Force (MPF) Vessels
Solicitation number
N32205-21-R-4117
Issued by

About this file

This document contains technical exhibits for the operation and maintenance of communications suites aboard Maritime Prepositioning Force vessels. Exhibit 1 lists the equipment and systems aboard each vessel class that will be maintained by the contractor, including COMSATCOM, MILSATCOM, fleet broadcast, IP/telephone, tactical voice and data systems, ADPE networks, cryptology, portable test equipment, and other miscellaneous systems. Exhibit 2 outlines the furnished facilities and equipment aboard each vessel, distinguishing between durable movable property that is reimbursable or non-reimbursable by the government. Exhibit 3 provides estimated man-hours for preventative maintenance of each system per quarter and year. Exhibit 4 details the current preventative maintenance requirements and recommended periodicity for each system, including inspection, testing, cleaning, and adjustment procedures.

View the file

Other files

File Type Posted
N32205-21-R-4117-0007.pdf PDF
N32205-21-R-4117 conformed through Amend 0007.pdf PDF
N32205-21-R-4117 conformed through Amend 0006.pdf PDF
Attach V - Communications Suite Technical Exhibits (TE) 1-4 - Amend 6.pdf PDF
N32205-21-R-4117-0006.pdf PDF
Attach P - Pricing Forms A-C - Amend 5.xlsx XLSX spreadsheet
N32205-21-R-4117 conformed through Amend 0005.pdf PDF
N32205-21-R-4117-0005.pdf PDF
N32205-21-R-4117-0004.pdf PDF
N32205-21-R-4117 conformed through Amend 0003.pdf PDF
N32205-21-R-4117-0003.pdf PDF
Attach C - DD254 - Amend 3.pdf PDF
Attach G - SF LLL - Amend 3.pdf PDF
Attach L - Total Evaluated Price Form - Amend 3.xlsx XLSX spreadsheet
Attach L - Total Evaluated Price Form - Amend 2.xlsx XLSX spreadsheet
Attach W - ALMSC Naval Message 251231ZJAN18 - Amend 2.pdf PDF
N32205-21-R-4117-0002.pdf PDF
Attach P - Pricing Forms A-C - Amend 2.xlsx XLSX spreadsheet
N32205-21-R-4117 conformed through Amend 0002.pdf PDF
N32205-21-R-4117-0001.pdf PDF
Attach B - CBA-2019-12516-1 and CBA-2019-12518-1 r1.pdf PDF
Attach F - Request for Clarification or Question.docx DOCX document
N32205-21-R-4117.pdf PDF
Attach L - Total Evaluated Price Form.xlsx XLSX spreadsheet
Attach Q - GFP lists.zip ZIP file
Attach J - MECSP Worksheet.pdf PDF
Attach B - CBA-2019-12516-1 and CBA-2019-12518-1.pdf PDF
Attach O - Oversight and Metrics.pdf PDF
Attach N - Contract Deliverables.xlsx XLSX spreadsheet
Attach N - CDRL.pdf PDF
Attach E - American Institute Hull Clauses.pdf PDF
Attach U-Training Information.pdf PDF
Attach I - Past Perf Narrative.doc DOC document
Attach G - SF LLL.pdf PDF
Attach B - CBA-2019-12514-2.pdf PDF
Attach C - DD254.pdf PDF
Attach M - Award Fee Plan.pdf PDF
Attach K - Technical Proposal Datasheets.docx DOCX document
Attach P - Pricing Forms A-C.xlsx XLSX spreadsheet
Attach H - Invoice Requirements.pdf PDF
Attach T - Reimbursable Expenses.docx DOCX document
Attach B - CBA-2019-12515-1.pdf PDF
Attach D - P and I Guidelines.pdf PDF
Attach R - Monthly Budget Status Report.xlsx XLSX spreadsheet
Show all 44

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TE-1 EQUIPMENT AND SYSTEMS

The list below outlines the equipment/systems on each vessel that will be under the contractor’s cognizance. The “system” extends from the equipment to all associated antennae and devices. These lists may not be all inclusive and the government reserves the right to upgrade/change the equipment at any time.

T-AK CLASS

Function Current Navy/MSC System

COMSATCOM (SECURE VOICE

AND DATA)

BEST OR NEXT GENERATION WIDEBAND (NGW) INMARSAT

(L, Ku, C, X-BAND), SATURN NERA BM, CBSP

MILSATCOM SECURE VOICE OE-82C/WSC-1 with (1/2) AN/WSC-3(V) and a TD-1271/U

AN/WSC-3(V), OK454/WSC (DAMA), 5kHz SATCOM MODEM, AN/PRC-117F, DMR/UHF AN/USC-61

MILSATCOM SECURE DATA OE-82C/WSC-1 with (1/2) AN/WSC-3(V) and a TD-1271/U

AN/WSC-3(V), OK454/WSC (DAMA), MD-1324/U

(5kHz SATCOM MODEM), AN/PRC-117F, DMR/UHF AN/USC-61

FLEET BROADCAST

(RECEIVE ONLY)

AN/SSR-1A/TD-1063A/AM6534

GENSER MESSAGE AN/SYQ-7B/AN/SYQ-26 (V)4 (NAVMACS II/SMS), NOW (NAVY

ORDER WIRE), FSM, OIX, PPTS

IP/TELEPHONE ROUTING AUTOMATED DIGITAL NETWORK SWITCH (ADNS AN/USQ-144(V)

INC III) OR CURRENT VERSION; MITEL SX-200 PBX

TACTICAL VARIANT SWITCH AN/USQ-155Q

TACTICAL VOICE TERMINAL CT-2200/2250

GLOBAL POSITIONING SYSTEM AN/WRN-6(V), R-2331D/URN RECIEVER

SECURE AUDIO SWITCHING C-10315/10316, TA-970/980/990, AM-3729, LS-474, MSAS

TACTICAL HF/VHF/UHF

(SECURE/NON SECURE) VOICE

AN/WSC-3(V), AN/VRC-92F (SINCGARS), RT-1523E,

R-2368, HF MICOM RM500/RM500R, RF-5800, LOS DMR AN/USC-61

ADPE LAN (NIPRNET/SIPRNET) FAST ETHERNET BACKBONE WITH CLIENT/ SERVER

ARCHITECTURE RUNNING ON /2003/XP PLATFORMS,

WITH PERIPHERALS RUNNING COMMERCIAL AND MSC

SPECIFIC APPLICATIONS INCLUDING CITRIX THIN-CLIENT,

ISNS A (v) 5 OR INSTALLED VERSION AN/USQ-153 (V)

CRYPTOLOGY KG-175, SKL, STE, TSEC/KG-84A, TSEC/KY-58,

KGV-11 (ANDVT), TSEC/KWR-46, ISM (IRIDIUM SECURE

MODULE ), MD-1324/U, KIV-7M, CMWS

PORTABLE HAND HELD

RADIO EQUIPMENT

IRIDIUM, VARIOUS MAKE AND MODEL OF VHF/UHF RADIOS

TEST EQUIPMENT T-BERD, OSCOPE, SPECTRUM ANALYZER

OTHER SYSTEMS TACAN AN/URN-25, CENTRIX, GCCS-M, TV-DTS

TE-2

FURNISHED FACILITIES AND EQUIPMENT

DURABLE MOVABLE PROPERTY (NON-REIMBURSABLE)

REPRESENTATIVE LIST*

(a) General Purpose Electronic test equipment, such as voltmeters, ammeters, oscilloscopes, ohmmeters and multimeters.

(b) Furniture, such as chairs, lamps, tables and file cabinets.

*NOTE: This list is representative of the types of durable movable property (non-reimbursable) aboard ship. A detailed list by item, quantity and identifying number will be prepared and finalized during the joint inspection prior to commencement of the contract.

DURABLE MOVABLE PROPERTY (REIMBURSABLE)

REPRESENTATIVE LIST*

Typewriter, Shredders, Fax Machine, Laptops

*NOTE: This list is representative of the types of durable movable property (reimbursable) aboard ship. A detailed list by item, quantity and identifying number will be prepared and finalized during the joint inspection prior to commencement of the contract.

SENSITIVE PROPERTY (REIMBURSABLE)

STU IIIs

NOTE: This list of Sensitive Property is definitive in that all items on this list are Sensitive Property by definition and all items not on this list are excluded from the term " Sensitive Property". A detailed list by item, quantity and identifying numbers will be prepared prior to turnover of each comm. suite.

GENERAL USE CONSUMABLE SUPPLIES (NON-REIMBURSABLE)

Adhesives Calipers Industrial Earmuffs Rubber Bands Binders Ear Plugs Ink Pads Rulers Binders Envelopes Ink Refills Safety Goggles Boxes Erasers Junction Boxes Safety belts Bandages Detergents Gloves Staples Batteries (AA, AAA, C, D cells)

Flux Glue Scissors

Bulbs Heat Guns Markers Soldering kits Calculators Whole Punchers Pencils Tapes Calendars Hose Clamps Pens Yard Sticks Copy toner Index Cards Rags NOTE: This list is not intended to be all-inclusive, but is provided to indicate the range and types of items that may be required to operate/maintain comm. suite equipment.

TE-3

ESTIMATED MAN-HOURS

REVISED REVISED NOTES

M/H PER M/H PER

MIP SYSTEM FUNCTION QUARTER YEAR

3000/001-59 MISC. SHIPBOARD ELECT EQUIP Miscellaneous X X Assessment not done-EGL unknown 4402/001-79 OK-454(V) UHF SATCOM DAMA System 7.4 29.6 Based on 1 unit per ship 4402/002-49 OE-82( )/WSC-1 UHF SATCOM DAMA System 1.8 6.9 Based on 1 unit per ship 4402/003-49 AN/SSR-1, 1A UHF SATCOM Receive System 1.8 7 Based on 1 unit per ship 4403/001-49 FREQUENCY DISTRIBUTION SYS HF XMT/RCV, UHF/VHF Line of Sight 0.5 2 Based on 1 unit per ship 4411/006-49 DIPOLE ANTENNAS UHF/VHF Line of Sight 1.6 6 Based on 4 units per ship 4411/011-49 WHIP ANTENNAS - SURFACE HF XMT/RCV 15 60 Based on 5 units per ship 4412/014-B7 AN/URA-38( ) HF XMT/RCV 6.4 25.6 Based on 4 units per ship 4413-004-49 AN/URT-23( )(V) HF XMT/RCV 10 40 Based on 4 units per ship 4414/002-49 R-1051( )/URR HF XMT/RCV 5.2 20.8 Based on 5 units per ship 4414/010-58 R-2368( )/URR, R-2368A(V)1/URR HF XMT/RCV 1.2 5 Based on 5 units per ship 4415/032-79 AN/WSC-3(V)6,7,8,11,14 (LOS) UHF/VHF Line of Sight 15 60 Based on 5 units per ship 4416/012-B7 AUDIO FREQUENCY AMPLIFIERS HF XMT/RCV, UHF/VHF Line of Sight 0.5 2 Based on 10 units per ship 4417/203-79 AN/WSC-3(V)1,2,3,9,13,15,16,17,19 UHF SATCOM DAMA System 7 28 Based on 2 units per ship 4417/208-19 INMARSAT B SYSTEM NIPRNET/SIPRNET 8.1 32.4 Based on 1 unit per ship 4419/R02-18 AN/SYQ-7(V)1,2,3,5,5A NAVMACS(V)2/DMS 12.3 49.1 Based on 1 unit per ship 4451/R21-28 COMM PATCH PANELS NAVMACS(V)2/DMS, NOW 0.8 3 Based on 6 units per ship 4451/R25-46 AN/URA-17, 17A, 17B, 17C, 17D HF XMT/RCV 2.2 8.8 Based on 4 units per ship 4461/001-79 SECURITY EQUIPMENT COMSEC Devices 4.7 18.8 Based on 25 units per ship 4911/001-39 PORTABLE ELECT TEST EQUIP Test Equipment 1 4 Based on 40 units per ship 6561/001-59 PAPER SHREDDER 0.9 3.4 Based on 1 unit per ship 6561/004-C8 PAPER SHREDDER GENERIC ALL SHREDDERS 0.6 2.5 Based on 1 unit per ship 6561/020-C8 PAPER SHREDDER 0.7 2.6 Based on 1 unit per ship C-056/001-48 AN/SRA-12, 12A,12B,12C HF XMT/RCV 0.3 1 Based on 1 unit per ship

TOTAL MANHOURS 105 418.5

(PMS man-hours to be provided for equipment: NOW, LST-5, BT-BEST, AN/GRC-171, AN/URC-94)

TE-4

PREVENTIVE MAINTENANCE SYSTEM

MIP SYSTEM CURRENT MAINTENANCE REQUIREMENT M/H PER REQUIRED RECOMMEND

PERIODICITY EQUIP. Y/N PERIODICITY

3000/001-59 Misc. Shipboard Elec.

Equipment Q-1R 1. Inspect Portable Tools with 3-prong plug 0.2

2. Measure device's ground conductor/insulation resistance Q-2R 1. Inspect Portable Tools with 2-prong plug 0.2

2. Measure insulation resistance Q-3 1. Perform safety test of Biddle tool tester 0.5 Q-4 1. Perform safety test of Power-R-Safe tool tester (with 0.2 test rig) Q-5 1. Perform safety test of Power-R-Safe tool tester (without 1.0 test rig) S-2 1. Inspect installed receptacles (exposed to weather) 1.0

2. Measure circuit resistance S-6 1. Inspect shorting probe 0.2

2. Measure continuity of shorting probe A-1 1. Inspect installed receptacle (not exposed to weather) 0.2

2. Measure ground circuit resistance A-3R 1. Inspect electrical submersible pump 0.4 A-4R 1. Inspect surge suppressor 0.1

2. Measure surge suppressor resistance A-5 1. Measure grounding circuit resistance of elec. Equip 0.1 mounted on non-structural bulkheads A-6 1. Inspect mobile electrical equip. with 2-prong plg 0.4

2. Measure insulation resistance

3. Measure current on exposed metal parts

3000/001-59 Misc. Shipboard Elec. Equipment A-7 1. Inspect mobile electrical equip. with 3 or 4 prong plugs 0.4

Continued 2. Measure devices ground conductor and insulation Resistance

A-8R 1. Inspect extension cord 0.2

2. Measure circuit resistance

24M-1 1. Inspect bonding strap/grounding bus 0.2

2. Measure ground circuit resistance

R-1 1. Clean insulating rubber gloves 0.2

R-2 1. Inspect mobile electrical equipment with 3 prong plugs 4.0

R-3 1. Inspect insulating rubber gloves (near switchboards) 0.1

4402/001-79 OK-454(V), 455(V) M-3 1. Clean TD-1271B/U multiplexer air intake and 1.2 Y M Control Monitor Group air exhaust filters

2. Perform TD-1271B/U multiplxer alarm and lamp test

S-1 1. Adjust crystal oscillator 3.0 Y S

S-2R 1. Clean, inspect and secure TD-1271B/U 1.2 Y A

S-3R 1. Clean, inspect and secure power distribution panel 2.0 N

2. Clean, inspect and secure MX-10342/WSC mon. panel

3. Secure SB-4124/WSC data and control patching Switchboards

4. Clean, inspect and secure SB-4125/WSC IF patch panel

5. Clean, inspect and secure blower

6. Restore control monitor group to readiness condition

A-1 1. Clean cabinet exhaust louver panel on rear equip chassis 2.0 Y A

A-4 1. Clean and inspect circuit card assemblies 2.4 N

R-1W 1. Clean cabinet blower assembly and filter 0.5 Y M

2. Clean exterior of equipment rack

3. Perform lamp test

4402/002-49 OE-82B, C/WSC-1(V) Q-11 1. Test transmission line and amplifier-filter pressurization 0.1 Y Q

OE-82D/WSC

S-13R 1. Conduct antenna group performance tests 1.0 N

S-16R 1. Perform OE-82( ) RF power arc test 2.0 N

A-7 1. Clean, inspect and lubricate OE-82( ) antenna group 2.0 Y A

A-9 1. Purge OE-82 ( ) transmission lines 1.0 N

A-14R 1. Measure OE-82( ) preamplifier gain 1.1 Y A

2. Measure OE-82( ) preamplifier gain (remove preamp)

18M-2 1. Clean and inspect slipring assembly contacts 3.4 Y 18M

18M-6 1. Measure RF transmission line losses 1.6 Y 18M

R-5M 1. Rotate antenna 0.5 N

MIP SYSTEM CURRENT MAINTENANCE REQUIREMENT M/H PER REQUIRED RECOMMEN

D

PERIODICIT

Y

EQUIP. Y/N PERIODICIT

Y

4402/003-49 AN/SSR-1, 1A Q-1R 1. Perform system operational test 1.0 Y S

S-4R 1. Inspect and secure for hostile environment 0.5 N

A-3 1. Adjust local oscillator frequency 2.2 Y A

2. Adjust PSK frequency

3. Adjust bit sync frequency

A-42 1. Clean and inspect SSR-1 amplifier-converters/antennas 1.0 Y A

R-22 1. Clean and preserve SSR-1 antennas/downconverters 1.8 Y A

4403/001-49 Frequency Distribution System M-1 1. Test operate frequency standard AN/URQ-10( ) 1.1 N/A

2. Exercise battery

Q-2 Exercise frequency time standard AN/URQ-23 battery 0.1 Y Q

S-2 1. Measure AM-2123( )(V) amplifier channel outputs 0.2 Y S

A-1 1. Test operate frequency time standard AN/URQ-23 0.5 Y A

R-1 1. Deliver frequency standard AN/URQ-10 to 0.3 N/A calibration activity

R-2 1. Receive frequency standard AN/URQ-10 from 0.3 N/A calibration activity

R-3 1. Deliver frequency time standard AN/URQ-23 to 0.5 Y 20M calibration activity

R-4 1. Receive frequency time standard AN/URQ-23 from calibration activity

0.2 Y 20M

4411/006-49 Dipole antennas A-43 1. Inspect and clean VHF/UHF antenna 1.5 Y A

2. Measure VSWR

60M-1 1. Schedule removal and overhaul of antennas during shipyard availability

4411/011-49 Whip antennas - Surface S-2 1. Inspect, clean and lubricate antenna tilting platform

2.0 N/A

S-18R 1. Clean and inspect whip antenna 6.0 Y S

2. Clean and inspect matching unit, coupler, tuner, or junction box, and insulators

3. Measure antenna insulation resistance

4. Measure metal whip antenna continuity

R-24 1. Inspect antenna tilting platform locking device 4.0 N/A

4412/014-B7 AN/URA-38( ), RF-

601A/C M-1 1. Clean and inspect antenna coupler group 1.3 Y Q

2. Observe antenna coupler group pressure

Q-1 1. Test operate antenna coupler group 0.3 Y Q

Q-2 1. Test operate antenna coupler group

(DD-963 class)

0.6 N/A

S-1 1. Clean and inspect antenna coupler control 0.3 N

4413/004-49 AN/URT-23( )(V) M-3 1. Clean AN/URT-23( )(V) radio transmitting set air filters

0.2 Y M

2. Test operation of air vane switch and alarm circuit

Q-2/A-2 1. Test and adjust T-827( )/URT, R-1051( )/URR, 0.6 Y A RT-618( )/URC internal frequency standard

S-4R 1. Measure AN/URT-23C(V)1, D normal mode 1.5 N intermodulation distortion

2. Measure AN/URT-23C(V)1, D data mode intermodulation distortion

S-5R 1. Measure AN/URT-23( )(V) power out and frequency 3.0 Y S Accuracy

S-22 1. Clean, inspect and lubricate AN/URT-23( )(V) 1.6 N transmitting set

A-22 1. Test AN/URT-23( )(V) radio transmitting set 0.6 Y A interlock switches

R-7 1. Measure T-827( )/URT, R-1051( )/URR, 0.4 Y A RT-618( )/URC 20-volt regulated supply

4414/002-49 R-1051( )/URR Q-2/A-2 1. Test and adjust T-827( )/URT, R-1051( )URR, 0.6 Y A RT-618( )/URT internal frequency standard

Q-19 1. Test R-1051( )/URR radio receiver AGC circuit 2 Y S

2. Measure receiver sensitivity

3. Test frequency locking action

S-1 1. Clean, inspect and lubricate R-1051( )/URR receiver 0.3 N

S-12 1. Test R-1051( )/URR radio receiver interlock 0.1 Y S

R-7 1. Measure T-827( )/URT, R-1051( )/URR, 0.4 Y A RT-618( )/URC 20-volt regulated supply

4414/010-58 R-2368, 2368A,B, R-368A(V)1 A-1 1. Measure receiver sensitivity 1 Y A

2. Test receiver AGC

3. Measure internal frequency standard

4415/032-79 AN/WSC-3(V)6,7,8,11,14 (LOS) 2M-1 1. Exchange, inspect, and clean AN/WSC-3(V)( ) LOS 0.3 Y Q air filter

S-1 1. Clean AN/WSC-3(V)( ) LOS front louver assembly 0.9 Y S

2. Clean EMI filter, lubricate, and inspect unit

3. Conduct BITE test

S-2 1. Measure AN/WSC-3(V)( ) LOS 5 Mhz frequency output

0.6 Y S

2. Measure TCXO or VCXO control voltage and frequency

A-1R 1. Measure AN/WSC-3(V)( ) LOS receiver AM/FM sens. 2 Y A

2. Measure receiver squelch sensitivity

3. Measure narrowband receive audio output

4. Measure AM wideband receive audio output

5. Measure Link 11 receive audio output

A-2R 1. Measure AN/WSC-3(V)( ) LOS AM narrowband 1 Y A Modulation

2. Measure AM wideband modulation

3. Measure AN/WSC-3(V)11 data buffer AM modulation and sidetone

A-3R 1. Measure AN/WSC-3(V)( ) LOS FM narrowband 1.2 Y A transmit deviation

2. Measure FM wideband transmit deviation

A-4 1. Clean, inspect and weatherproof C-9351( )/WSC-3 1 N Control Indicator (CIN)

R-2 1. Conduct AN/WSC-3(V)( ) LOS communications set 0.3 Y R performance tests

4416/012-B7 Audio Frequency Amplifiers A-1 1. Clean and inspect audio amplifier units

0.2 Y A

4417/203-79 AN/WSC-3,3(V)1,2,3,9,13,15,16, Q-1 1. Measure VCXO control voltage 1.4 Y Q 17,19 (SATCOM) 2. Conduct communications set performance test

Q-2 1. Clean AN/WSC-3(V)( ) communications set air filter

0.3 Y Q

2. Clean EMI filter

3. Inspect radio set and lubricate slide assemblies

A-1R 1. Conduct transmitter power out test of RT-1107

( )/WSC transceiver set 3 Y A

2. Conduct power out test of combiner circuits in OK-326 equipment rack

A-2R 1. Measure AN/WSC-3(V)( ) receiver AM sensitivity 2.2 Y A

2. Measure receiver FM sensitivity

A-3R 1. Verify voltage regulator voltages 2 Y A

2. Measure AN/WSC-3(V)( ) 5 Mhz frequency output

3. Accomplish AFC sweep performance test

4. Accomplish VCXO performance test

5. Accomplish PSK AFC/AGC performance test

6. Verify PSK integrator output

7. Verify bit timing VCXO frequency

8. Test data signal acquisition lamp action

4417/208-19 INMARSAT

A/B/M Q-1 1. Perform UPS battery test 0.6 Y Q

Q-2R 1. Clean and inspect antenna 1 Y Q

R-1 1. Recharge UPS batteries 1 Y Q

R-2 1. Perform system verification test (Inmarsat A only) 0.5 Y R

R-3 1. Perform system verification test (Inmarsat B/M only) 0.5 Y R

R-4W 1. Clean and inspect operator workstation (Inmarsat A) 0.5 Y M

R-5W 1. Clean and inspect operator workstation

(Inmarsat B/M)

0.5 Y M

R-6M 1. Clean and inspect printer 0.8 Y M

4419/R02-18 AN/SYQ-7(V)1,2,3,5,5A M-1 1. Clean and inspect UYK-20 air filter 0.5 Y M

M-2 1. Clean and inspect USQ-69 air filter 0.5 Y M

2. Test battery

M-3 1. Clean and inspect UYK-44 air filter 0.2 Y M

2. Perform overtemperature alarm test

M-5 1. Clean equipment air filters: ON-143, RD-396, USH-26 0.6 Y M

RD-397, RD-433, TT-624

M-6 1. Clean and inspect USH-26 tape drive unit 0.3 Y M

M-7 1. Clean and inspect TT-624 print mechanism 0.8 Y M

2. Clean and inspect electronic bay

3. Perform self test

M-8 1. Clean RD-396 cassette magnetic tape unit tape heads 0.1 N/A and tape path

Q-1 1. Clean USH-26 rear panel air filter, and inspect recorder- reproducer

2.0 Y Q

2. Inspect drive belt and measure belt tension

3. Measure tape speed

4. Measure read gain

Q-2R 1. Clean RD-397 paper tape reader-punch 0.3 Y Q

Q-3 1. Clean and inspect RD-433 mass memory 0.3 N/A

2. Perform mass memory lamp test

Q-4 1. Check RD-433 battery charge condition indicators 0.3 N/A

4419/R02-18 AN/SYQ-7(V)1,2,3,5,5A S-1 1. Inspect equipment cabinets, and test interconnecting 0.8 N Continued group chassis safety interlock for ON-143, RD-396, RD-397

S-2 1. Clean and inspect UYK-20 data processing set 2.8 N

S-3 1. Clean RD-433 digital magnetic disk recorder-reproducer

1.5 N/A

2. Perform control and indicator test

3. Exchange battery assembly with Operating Space Item (OSI) assembly and perform battery charge test

A-1 1. Clean and inspect USQ-69 cabinet 1.1 Y A

2. Clean keyboard

3. Test battleshort switch and display drawer safety interlock switch

A-2 1. Clean UYK-44 cabinet interior 0.3 Y A

2. Perform BIT test

R-1 1. Ensure tightness of mechanical fasteners and couplings on USH-26, RD-397, USQ-69, UYK-44,

2.5 Y A

TT-624, RD-433

R-2 1. Clean USH-26 tape drive magnetic heads and drive 0.1 Y M Wheel

4451/R21-28 Communications patch panel A-1 1. Inspect and clean communications patch panel

0.5 Y A

4451/R25-46 AN/URA-17, 17A, B, C, D A-1 1. Measure AN/URA-17 power supply voltages

1.4 Y A

2. Test tuning indicator centering

3. Test discriminator operation

4. Test keyer function

A-2 1. Clean and inspect AN/URA-17 0.8 Y A

2. Test safety interlocks

4461/001-79 Security equipment Q-1 1. Measure KY-57 fill battery voltage 0.2 N/A

Q-2 1. Measure KY-58 battery voltage 0.2 Y Q

Q-5 1. Measure KW-46 battery voltage 0.1 Y Q

Q-6 1. Measure KG-84, 84A, 84C battery voltage 0.1 Y Q

Q-7 1. Measure KY-75, 75A battery voltage 0.1 N/A

Q-8 1. Measure KYV-5 battery voltage 0.2 Y Q

Q-9 1. Measure Fill Device battery voltage 0.2 Y Q

Q-10 1. Measure KI-1C battery voltage 0.1 Y Q

Q-11 1. Measure KIV-7 battery voltage 0.2 N/A

Q-12 1. Measure KY-99A fill battery voltage 0.1 N/A

S-1 1. Inspect and test fill device fill connectors 0.2 Y S

2. Inspect and test fill cable fill connectors

S-2 1. Inspect and test KG-45 fill connector 0.1 N/A

A-1R 1. Clean KG-36 permuter tray holder,and inspect door cover RF gasket and mating surface

0.6 N/A

2. Inspect drawer slides

3. Inspect front panel RF gasket and mating surface

4. Clean, inspect and secure for hostile environment

A-2R 1. Clean, inspect and secure KG-40A equipment 0.3 N/A

2. Inspect and test fill connector

4461/001-79 Security equipment A-3 1. Inspect and test KGR-96 fill connector 0.1 N/A Continued A-4R 1. Clean, inspect and secure KW-46 equipment 0.3 N

2. Inspect and test fill connector

A-5 1. Inspect and test KY-75 fill connector 0.1 N/A

A-6 1. Inspect and test KY-58 fill connector 0.1 N

A-7R 1. Clean, inspect and secure KG-84 equipment 0.3 N

2. Inspect and test fill connector

A-8 1. Inspect and test KYV-5 fill connector 0.1 N

A-9 1. Inspect and test KI-1C fill connector 0.1 N

A-10 1. Inspect and test KIV-7 fill connector 0.1 N/A

A-11 1. Inspect and test KY-99A fill connector 0.1 N/A

A-12R 1. Clean , inspect and secure KG-194 equipment 0.3 N/A

A-13 1. Inspect and test KG-194 fill connector 0.1 N/A

A-14 1. Inspect and test KY-57 fill connector 0.1 N/A

A-15R 1. Inspect KG-95 KSD and fill connectors 0.1 N/A

2. Test fill connector

MIP SYSTEM CURRENT MAINTENANCE M/H PER REQUIRED RECOMMEND

PERIODICITY REQUIREMENT EQUIP. Y/N PERIODICITY

4911/001-39 Portable electronic test equipment 18M-1/R-1 1. Inspect test equipment 0.1 Y A

2. Inspect power cord

3. Test operate test equipment

6561/001-59 Paper shredder S-1 1. Clean, inspect and lubricate shredder

0.5 Y S

R-1 1. Lubricate cutting assembly 0.2 Y ~M

6561/004-C8 Paper shredder Q-1 1. Clean shredder 0.4 Y Q

S-1 1. Test limit switch 0.2 Y S

A-1 1. Inspect drive belts and lubricate rotor bearings

0.5 Y A

6561/020-C8 Paper shredder Q-1 1. Test emergency stop switch 0.5 Y Q

2. Test door switch

3. Clean, inspect and lubricate shredder

S-1 1. Clean, inspect and lubricate chain and synchronizing gears

0.3 Y S

C-056/001-48 AN/SRA-12, 12A, B, C A-1 1. Inspect electrical filter assembly 1 Y A

2. Measure resistance of electrical filter assembly

3. Test electrical filter assembly

FOR OFFICIAL USE ONLY
NOT TO BE RELEASED UNDER FOIA
ELECTRONIC DATA INTERCHANGE
VII. INTERRUPTION OF SERVICE
ATTACHMENT J-9