WI_1011_-_TROLLEY_STOWAGE_ARMS_MOD_ARCTICROH14R2.pdf
PDF 13 KB Posted
- Attached to
- REGULAR OVERHAUL/DRYDOCK FOR USNS ARCTIC
- Solicitation number
- N32205-14-R-2000
About this file
WORK ITEM 1011
View the file
Other files
Show 40 more
Latest 50 of 58 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
USNS ARCTIC
(T-AOE 8)
UNREP GEAR RFP NO. N32205-14-R-2000
6 January, 2014 ITEM NO. 1011 Category "A" PHDNSWC/KRUG/jb
STATION NO.6 TROLLEY STOWAGE ARMS MODIFICATIONS
1011-1
1.0 ABSTRACT
This item describes the requirements for modifications to the Station No. 6 Trolley Stowage Arms
2.0 REFERENCES
2.1 NAVSEA Drawing No. 8287352, Stowage Arm, Machining
3.0 ITEM LOCATION/DESCRIPTION
3.1 Location/Quantity
3.1.1 Location: Various
3.1.2 Quantity: 2
3.2 Item Description/Manufacturer's Data
3.2.1 Bill of Materials
PC No. QTY Description 1 2 Right and left hand trolley stowage arms. See Reference 2.1.
3.2.2 Quantities are considered estimates. The
Contractor shall provide the exact quantities and additional material such as miscellaneous pipe fittings, elbows, caps, valves, pipe hangers, weld material, cable hangers, cable tags, buswork, etc., which are not included in the List of Materials, in order to install a fully functional system which meets the requirements of this specification.
4.0 GOVERNMENT FURNISHED EQUIPMENT/MATERIAL/SERVICES
4.1 Government Furnished Equipment (GFE): None Additional.
4.2 Government Furnished Material (GFM): None Additional.
1011-2
4.3 Government Furnished Services (GFS)
Port Hueneme representative will provide technical support/guidance during the accomplishment of this work item.
4.4 Government Furnished Information (GFI): None Additional.
5.0 NOTES
5.1 The contractor and all subcontractors, regardless of
tier must consult the General Technical Requirements (GTR) to determine applicability to this work item. In performance of this work item, the contractor and all subcontractors regardless of tier must comply with the requirements of all applicable GTR’s including but not limited to GTR’s 1-7, 22, 23, 24, 28 and 29.
5.2 The contractor and all subcontractors, regardless of
tier, are advised to review other work items under this contract to determine their effect on the work required under this work item.
5.3 Contractor Furnished Materials (CFM)
Contractor is to supply Anti-seize compound (MIL-PRF- 907), Grease (MIL-PRF-24139A), and other consumables as required.
5.4 All equipment identified for removal and re-installation
shall be tagged, segregated and preserved to ensure equipment availability upon request of installing activity
6.0 QUALITY ASSURANCE REQUIREMENTS: None Additional.
7.0 STATEMENT OF WORK REQUIRED
7.1 Arrangements/Outfitting: None Additional.
7.2 Structural: None Additional.
7.3 Mechanical/Fluids
1011-3
7.3.1 Fabrication
Fabricate right and left hand trolley stowage arms in accordance with Reference 2.1.
7.3.2 Removals
Remove existing trolley stowage arms on Station No. 6 Heavy Unrep Transfer Head.
7.3.3 Installations
Install fabricated trolley stowage arms on Station No. 6 Heavy Unrep Transfer Head.
7.4 Electrical: None Additional.
7.5 Electronics: None Additional.
7.6 Preparation of Drawings/Documentation/Test Memo: None
Additional.
7.7 Inspection/Test
7.7.1 Operational test
a. Trolley arms will be tested by swinging open and closed to ensure freedom of movement.
b. During system operation, trolley should seat properly in the trolley stowage arms. Proper seating can be verified by Port Hueneme and/or ship personnel.
7.8 Painting
Paint all new and modified surfaces to match surrounding surfaces.
1011-4
7.9 Marking
Install name plates, notices, and markings for all new and modified systems (or areas).
7.10 Manufacturer's Representative
Government representatives from NSWC will be on site to provide technical oversight and guidance upon request from contractor
8.0 GENERAL REQUIREMENTS: None Additional.
File details come from the government source that posted it. Updated .