MD3.1_-_ENLARGED_MECHANICAL_ROOM_DEMO_PLAN.pdf
PDF 318 KB Posted
- Attached to
- Volusia County Branch Jail Air Handler-Fire Suppression System Removal, Replacement and Upgrade
- Solicitation number
- 26-B-110IF
- Issued by
- Volusia County, Florida
About this file
This is an Enlarged Mechanical Room Demolition Plan prepared for the Volusia County Department of Corrections' Air Handler and Fire Suppression System Replacement project located at the Volusia County Branch Jail, 1300 Red John Drive, Daytona Beach, Florida. The plan, dated December 5, 2025, details the removal and replacement scope of work for multiple mechanical rooms within the facility. The project encompasses the demolition of existing Air Handling Units (AHUs) numbered 5, 8, 9, 11, and 12, along with associated ductwork, manual and motorized dampers, hot water coils, chilled water supply and return lines, and hot water supply and return lines. The contractor is responsible for disconnecting all HVAC piping at the riser points and preparing connections for new equipment installation. Additionally, the existing purge and exhaust fan systems are to be replaced in kind. The plan indicates that all manual and motorized dampers throughout the mechanical rooms require replacement as part of the new work scope.
The demolition plan establishes that the contractor bears full responsibility for verifying actual field conditions and making all necessary modifications to accommodate the removal and replacement work. The plan notes that existing equipment and ductwork dimensions are approximate and derived from a cursory field engineer visit and historical construction documents, requiring the contractor to determine exact locations and conditions before commencing work. Where existing ductwork and control wiring are of specified type, meet new work requirements, and remain in good condition, these components may be reused. The project's fire suppression system integration and building automation system upgrades are addressed through coordinated replacement across mechanical, controls, and fire/life safety systems to enable pod isolation capabilities during smoke or contamination events.
View the file
Other files
Show 40 more
Latest 50 of 128 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MANUAL
DAMPER
30"/30"
32"/28"
M
M
SD
22"/16"
18"/12"
AHU
9 2
HWC
X.4
HWC
X.2
HWC
X.1
HWC
X.3
HWC
X.5
SD
HWS/R
CHWS/R
MANUAL
DAMPER
30"/30"
DUCT TO SPACE
32"/28"
M
M
SD
32"/28"
AHU
5 2
SD
HWC
XA.3
HWC
XA.1
HWC
X.2
HWC
X.3
HWC
XA.2
HWC
X.1
REFERENCE NOTES
ALL MANUAL AND MOTORIZED DAMPERS TO BE
REPLACED. SEE NEW WORK PLANS.
REMOVE EXISTING AHU AND ASSOCIATED DUCT WORK IN
THE MECHANICAL ROOM UP TO POINTS OF DISCONNECT.
DISCONNECT ALL CHWS+R AND HWS+R RUNNING TO THE
AHU AND ASSOCIATED HEATING COILS.
X IN TAG REPRESENTS AHU NUMBER WHICH
CORRESPONDS WITH COIL TAG.
EXISTING PURGE/EXHAUST FAN TO BE REPLACED LIKE
FOR LIKE.
REMOVE EXISTING CHW AND HW PIPING BACK TO RISER
AND PREPARE FOR NEW CONNECTION.
GENERAL NOTES
ALL INFORMATION AND WORK SHOWN AS EXISTING WAS TAKEN FROM
NOTES FROM A CURSORY FIELD VISIT BY THE ENGINEER AND FROM PAST
CONSTRUCTION DOCUMENTS. EQUIPMENT AND DUCTWORK HAS BEEN
SHOWN IN AN APPROXIMATE WAY. CONSEQUENTLY, THE CONTRACTOR
SHALL BE RESPONSIBLE FOR DETERMINING ALL WORK NECESSARY TO
RENOVATE, ALTER, CHANGE, AND REPAIR EXISTING SYSTEMS BASED ON
THE ACTUAL FIELD CONDITIONS.
DETERMINE EXACT LOCATION OF ALL EXISTING EQUIPMENT, DEVICES
AND WIRING BEFORE COMMENCING WORK.
LOCATE AND PRESERVE ALL PORTIONS OF THE EXISTING HVAC SYSTEMS
WHICH SHALL REMAIN.
EXISTING DUCTWORK AND CONTROLS WIRING MAY BE REUSED WHERE
THEY ARE OF THE TYPE SPECIFIED, MEET THE REQUIREMENTS OF THE
NEW WORK AS DEFINED BY THE CONTRACT DOCUMENTS, AND REMAIN IN
GOOD CONDITION.
EXISTING DUCT SIZES PER AS-BUILT DRAWINGS. CONTRACTOR TO FIELD
VERIFY EXISTING CONDITIONS AND MAKE MODIFICATIONS AS NEEDED.
1.
2.
3.
4.
5.
A
54321
B
C
D
E
F
SCALE
APPROVED BY
CHECKED BY
SHEET NO.
TITLE
DRAWN BY
DATE
PROJECT NO.
REVISIONS
KEY PLAN
CA# 26308 I22569.00
SEAL
/3
/2
:0
:5
P M
ENLARGED
MECHANICAL
ROOM DEMO
PLAN
FDS
ESC
12/05/2025
50166610
V C
B J A
IR
H
A N
D L
E R
F
IR
E S
U P
P R
E S
S
IO
N S
Y S
T E
M R
E P
L A
C E
M E
N T
V o lu s ia
C o u n ty
D e p a rt m e n t o f
C o rr e c ti o n s
B
ID
S E
T
R e d J o h n D ri v e D a y to n a B e a c h
F L
800 N. Magnolia Ave Suite 1000 Orlando, FL 32803 407.843.5120
MD3.1
Eric Cepull PE 64750
0' 16' 32'8'
Scale: 3/16" = 1'-0"
MECHANICAL ROOM #9, #11, & #12 DEMO
Scale: 3/16" = 1'-0"
MECHANICAL ROOM #5, #8 DEMO
NO. DESCRIPTION DATE
BID SET 12/05/2025
| 50166610 - VCBJ Air Handler Fire Suppression_MECH_v22 |
| MD3.1 - ENLARGED MECHANICAL ROOM DEMO PLAN |
File details come from the government source that posted it. Updated .