Acceptance Test Plan DI-QCIC-80553.pdf

Data Item Description PDF 85 KB Posted

Attached to
Air Compressor Dryer & Piping Replacement
Solicitation number
M00146-08-T-9020
Issued by

About this file

Datat Item Description - Attachment 04

View the file

Other versions and copies of DI-QCIC-80553

File Revision Posted Attached to
Attachment_15_A00E_DI-QCIC-80553A.pdf Rev. A Amendment-1 RFP FA8119-25-R-0011 Multi-platform Sustainment Engineering Services Support
Attachment_14_A00E_DI-QCIC-80553A.pdf Rev. A Draft Solicitation FA8119-25-R-0011 Multi-platform Sustainment Engineering Services Support
DI-QCIC-80553A.PDF Rev. A MAGTF Common Handheld - M67854-18-R-2023
DI-QCIC-80553A.PDF Rev. A MAGTF Common Handheld (MCH)
DI-QCIC-80553_Rev_A_-_Acceptance_Test_Plan.pdf Rev. A Oceana Live Ops Modernization
DID_DI-QCIC-80553A.pdf Rev. A Combat Electromagnetic Environment Simulator
FA821316R3038_15-77003_DI-QCIC-80553A.pdf Rev. A PARTS KIT, ESCAPE SYSTEM
DI-QCIC-80553A_Acceptance_Test_Plan.pdf Rev. A SWTTR UWNSS UPGRADE
DI-QCIC-80553A_Acceptance_Test_Plan.pdf Rev. A SWTTR UWNSS UPGRADE
0312-05_-_Rugged_Panel_Modification_-_DID_DI-QCIC-80553A.pdf Rev. A AUTOMATIC DATA PROCESSING EQUIPMENT AND SUPPORT EQUIPMENT
L1WA28 CDRL A006 DI-QCIC-80553 Test Plan.pdf Revision not stated Plural Component Paint Dispensing System
L1WM01 CDRL A002 DI-QCIC-80553 Test Plan.pdf Revision not stated Waterjet System
L0TC15 CDRL A006 DI-QCIC-80553 Test Plan Factory signed.pdf Revision not stated Ultrasonic
L0TC15 CDRL A007 DI-QCIC-80553 Test Plan Site signed.pdf Revision not stated Ultrasonic
L0WA21 CDRL A007 DI-QCIC-80553 Test Plan Factory signed.pdf Revision not stated X-Ray Machine Upgrade (DDA)
L0WA21 CDRL A008 DI-QCIC-80553 Test Plan Site signed.pdf Revision not stated X-Ray Machine Upgrade (DDA)
L0WC07 CDRL A004 DI-QCIC-80553_T Test Plan signed.pdf Revision not stated Cold Roll Machine
L0WC17 CDRL A002 DI-QCIC-80553 Acceptance Test Plan signed.pdf Revision not stated Small Parts Paint Booth and Cure Oven
Acceptance Test Plan DI-QCIC-80553.pdf Same revision and size as this file Revision not stated UPGRADE OF ROTARY SCREW COMPRESSOR (RSC)
Acceptance Test Plan DI-QCIC-80553.pdf Same revision and size as this file Revision not stated Upgrade of Rotary Screw Compressor (RSC)
Show all 20

Who attaches DI-QCIC-80553

Other files

File Type Posted
updated drawings as of 4-29-2008 for FEMA 19949.pdf PDF
DSC_8609.JPG JPG image
DSC_8614.JPG JPG image
DSC_8615.JPG JPG image
Recommended Spare Parts List for Spares DI-ILSS-80293B.pdf PDF
DSC_8617.JPG JPG image
CDRLS FOR REPLACEMENT 300 PSIG DRYER AND PIPING SYSTEM -10-24-2007--FEMA 19949.doc DOC document
DSC_8606.JPG JPG image
DSC_8618.JPG JPG image
DSC_8605.JPG JPG image
Maintenance Test and Support Equipment Requirements List DI-ILSS-80294A.pdf PDF
DSC_8611.JPG JPG image
Past Performance Questionnaire —
Test Procedure DI-NDTI-80603.pdf PDF
Test Report DI-NDTI-80604.pdf PDF
M00146-08-T-9020 Client Auth Ltr.doc DOC document
Equipment Calibration Procedure DI-R-7065.pdf PDF
DSC_8608.JPG JPG image
Manuals Technical Modified Commercial DI-M-2071.pdf PDF
Design Review Data Package DI-E-5423.pdf PDF
Sample Lockout tagout procedure.pdf PDF
DSC_8607.JPG JPG image
DSC_8619.JPG JPG image
DSC_8604.JPG JPG image
Site Preparation Requirements and Installation Plan DI-MGMT-80033.pdf PDF
M00146-08-T-9020 Official Solicitation.doc DOC document
DSC_8610.JPG JPG image
DSC_8612.JPG JPG image
DSC_8613.JPG JPG image
DSC_8616.JPG JPG image
M00146-08-T-9020 Client Auth Ltr.doc DOC document
M00146-08-T-9020 Draft Solicitation.doc DOC document
CDRLS FOR REPLACEMENT 300 PSIG DRYER AND PIPING SYSTEM -10-24-2007--FEMA 19949.doc DOC document
Past Performance Questionnaire —
08-T-9020 Site Visit Instructions.doc DOC document
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

I

I

I ,1

I

I

DATA ITEM DESCRIPTION

m4rPmwd mmh 07@owe

!.‘mu 1. IOENTIFICAW NuMBER

Accap@lce lwst Plan DI-CUC- 80553

OEscnlmm/nJnPoEE

3.1 ‘be Acceptance ‘rest Plas details the criteria, perfonssrrca objectives ad list of tests to be perforsad by the cmtractor for acceptance tests on eystema ad equiprenta.

APPSOVAL GATE 5. OWKE of PPJMARY REEPONEisum (OPSI b. Onc APmrMLE 6b. G1OEP APPuCASLE

%%?{ G~213

APPWTION /NmmNELATEoNsNIP

7.1 Ibis data item d?mcriptbn [DID) cmtains the fo~t h =-t pr~~tiQI inatrurtima for the data prduct gamrated by * specific ad discrete teak raquimmnt sa delineated in * cmtract.

7.2 his DID is agplicsble to crmtracta requiring preparatim of en a plsn.

=@== ~st

7.3 ‘his DID supersedes DI-T-5147.

-VU LIMITATION *. a?PurMLE KlsME 9b, AMSC NUMSER

D. PSEPMAnON wSNWSIONE

10.1 POrrsat. The plan shall k in cmtractor’s format.

10.2 CQltent. ‘2he plan shell cretin the f0Un9ing:

10.2.1 Cmrxview. Consists of a brief description of tiw objectives of th a~ test. plsn, inc.hding flw diagrams, miles~s, personnel participkim, emi security rqrm-. mis section dw ida * f~l~:

10.2.1.1 ?lm diagram. A functional descriptirm of the accqtmce test program using a block diagram psrtraysl of the functima that eust be mt te satisfy the t.otel amqtenre prcgrsm. mnctiona shell be *red 1.0, 2.0, 3.0 etc...

10.2.1.2 Milestones. Identifies the stsrt ad aspectd mxpletifm dstes of each teat ixJ be perfo .

10.2.1.3 Psrticimtion. Identifies tk Governmenterd Contractor participetian roles ad re~ibilities.

10.2.1.4 Security. Identifi ard state briefly any security masures or guidalimss to be observed.

10.3 FEestertest list. Lists all test to be eccmqlished in the order they are tn b?

performed Separate lkinga for each location shall be provided. This listing ahsll include &e follwing:

(Crmtinuedml Page 2)

1.DISTRIBUTION STATEMENT

DIS21UBUI’KN~ & AmXwed for phlic release; distri)mtion is un2imi@d.

. -— .==. ,,,., -= . .— .-k.——. —...,... ..-. , -. , -----

Document provided by IHS Licensee=NADEP/5918326100, User=, 02/11/2003 06:12:08 MST Questions or comments about this message: please call the Document Policy Management Group at 1-800-451-1584.

DI-CC2C-80553

62* io. Prepsratim 2nstmcUms (continued)

10.3.1

10.3.2 m.

iO.3.3

Facility. Lmatim where the acmptance test i6 to be performd.

Itea nmber. N9ber for each piece of aquipruit or item, test will be perfomxl

Test descripti m. Nsmrsod brief descripUm of test to be perfoti.

10.3.4 Peraseters. ‘he nmber of cycles the test will be perforsed rud *lected perim-eters to~i%d. .

10.3.5 mui mmt locaUm. Current locatim of equipent to be tested or used in * acceptance test .

20:oqP&lry$ts. Provides a list of special or ummal tests arsl esaminetims satisfactory equi~t parfomsnce to specificaUma.

:&o.4~mn.2iS& ‘2he equimt list shall list s.21equi~t to be used in the listing shall inckle the follcuing:

10.4.1 RSt equilmant. List au teat Squiguem *:

a. Daacriptim.

b. riuwnclature.

c. Seria3 ?amber

10.4.2 slmort ewipt . List of 621 support equipmnt by:

a. Descriptim.

b. Nomenclature.

c. Saria2 Nmber

10.4.3 Special test equi~nt. List all apecia.1 test equiprent required to be des@?ed or constructed for we m the programOy:

a. Description.

b. rkumc.lature.

c. Date required.

10.5 Validatica procedure.

test results.

f

An cwemiew of the procedures that the contractor will use

“’.4e2of 2 Pegas

Document provided by IHS Licensee=NADEP/5918326100, User=, 02/11/2003 06:12:08 MST Questions or comments about this message: please call the Document Policy Management Group at 1-800-451-1584.