About this file

The document is a Room Schedule (Attachment "A") for Solicitation No. LI-14174, detailing specific space requirements for the Department of the Navy at the Puget Sound Naval Shipyard. The schedule outlines 17 distinct space requirements ranging from administrative and classroom spaces to warehouse, industrial, and laydown areas, with each requirement specifying precise details such as approximate total area, maximum occupants, network drops, partition height, intended use, wall sound transmission class (STC) rating, electrical outlets, and additional notes.

The requirements vary significantly in size and purpose, from small 60-500 square foot office and data closet spaces to large 120,000 square foot outdoor storage areas. Each requirement includes common specifications like RJ45 voice/data jacks, painted walls, carpeted or resilient floors, window coverings, and doors with locking capabilities. The spaces are designed to accommodate between 3 and 260 personnel across various functions including executive offices, training rooms, computer labs, physics labs, workshops, and storage areas. The document emphasizes flexibility, noting that offerors may propose multiple buildings/facilities to meet the total space requirements, with a preference for co-located spaces within 500 meters of each other.

View the file

Other files

File Type Posted
SIOP Lease Phase 2 SFO LI-14174_Amendment No 9_Signed.pdf PDF
ATTACH A_ROOM SCHEDULE 5 MAY 2025.pdf PDF
SIOP Lease Phase 2 SFO LI-14174_Amendment No 8.pdf PDF
ATTACH A_ROOM SCHEDULE 18 APR 2025.pdf PDF
SIOP Lease Phase 2 SFO LI-14174_Amendment No 7.pdf PDF
ATTACH A_ROOM SCHEDULE 7 APR 2025.pdf PDF
SIOP Lease Phase 2 SFO LI-14174_Amendment No 6.pdf PDF
SIOP Lease Phase 2 SFO LI-14174_Amendment No 5.pdf PDF
ATTACH A_ROOM SCHEDULE 1 APR 2025.pdf PDF
ATTACH A_ROOM SCHEDULE_UPDATED 17 MARCH 2025.pdf PDF
SIOP Lease Phase 2 SFO LI-14174_Amendment No 4.pdf PDF
SIOP Lease Phase 2 SFO LI-14174_Amendment No 3.pdf PDF
SIOP Phase 2 Lease Solicitation Industry Day.pdf PDF
SIOP Lease Phase 2 SFO LI-14174_Amendment No 2.pdf PDF
SFO LI-14174 Industry Day Flyer 2025.pdf PDF
SIOP Lease Phase 2 SFO LI-14174_Amendment No 1.pdf PDF
LI-14174_ATTACH D_GSA FORM 3517B GENERAL CLAUSES.pdf PDF
LI-14174_ATTACH G_GSA FORM 3516 SOLICITATION PROVISIONS.pdf PDF
LI-14174_ATTACH A_ROOM SCHEDULE.pdf PDF
LI-14174_ATTACH F_PROPOSAL TO LEASE SPACE.pdf PDF
LI-14174_ATTACH E_GSA FORM 3518 REPS AND CERTS.pdf PDF
LI-14174_ATTACH I_CERT OF SEISMIC COMPLIANCE.pdf PDF
LI-14174_ATTACH J_GENERAL ARCHITECTURE AND FINISHES.pdf PDF
SOLICITATION FOR OFFERS LI-14174_Signed.pdf PDF
LI-14174_ATTACH C_ SF 2 FORM US GOV LEASE FOR REAL PROPERTY.pdf PDF
LI-14174_ATTACH B_AREA OF CONSIDERATION.pdf PDF
LI-14174_ATTACH K_PRE-PROPOSAL INQUIRY FORM.xlsx XLSX spreadsheet
LI-14174_ATTACH H_FORM 12000 PRELEASE FIRE PROTECTION.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

No. Rooms Approx. Total Area (SF) Gross

Maximum Occupants

Network Drops Partition Height (C/H=Ceiling) or (S/S=Slab)

Intended use Wall STC Rating 110V Duplex Outlets

Notes / Other Requirements

1 400 1 1 C/H Executive Office 45 STC 2x 4duplex outlets

- RJ45 voice/data jacks

- Painted walls (semi-gloss)

- Carpeted floors

- Window Coverings

- Door with locking capability

2 800 2 2 C/H Single Office 45 STC 2x 4duplex outlets

- RJ45 voice/data jacks

- Painted walls (semi-gloss)

- Carpeted floors

- Window Coverings

- Door with locking capability

40 24,000 28/ea 2/ea C/H Academic Training 50 STC Per code

- 26 students, chairs/desks

- Instructor chair desk

- Supply storage cabinet

- Two (2) White/glass boards

- Painted walls (semi-gloss)

- Carpet floors

- Window coverings

- Door with locking capability

- RJ45 voice/data jacks

- Overhead projector and screen w/ ceiling power connection.

- Sound system

- Dimmable light switches

- Area for US Government to install two (2) smart touch boards w/ wall power connection.

- Two (2) entrances/exits

1 1,500 15 18 C/H Admin (instructors offices) STD Per code

- Cubicles with desks and chairs for 15 personnel.

- RJ45 voice/data jacks

- Painted walls (semi-gloss)

- Carpeted floors

- Window Coverings

- Door with locking capability

5 750 1/ea 2/ea C/H Admin (tenured instructors offices) 50 STC Per code

- RJ45 voice/data jacks

- Painted walls (semi-gloss)

- Carpeted floors

- Window Coverings

- Door with locking capability

5 750 5 2/ea C/H Admin (OC staff office) 50 STC Per code

- RJ45 voice/data jacks

- Painted walls (semi-gloss)

- Carpeted floors

- Window Coverings

- Door with locking capability

Requirement B: Approximately 52,680 SQFT of Administrative, Classroom, and Training Space to Accommodate Approximately 260 Personnel

SFO LI-14174, Amendment No. 7 Attachment "A" - Room Schedule

Maximum Occupants

Network Drops Partition Height (C/H=Ceiling) or (S/S=Slab)

Intended use Wall STC Rating 110V Duplex Outlets

Notes / Other Requirements

1 500 2 2 C/H Admin (Front office) 50 STC Per code

- RJ45 voice/data jacks

- Painted walls (semi-gloss)

- Carpeted floors

- Window Coverings

- Door with locking capability

1 1,500 240 0 C/H Locker Room STD Per code - Painted walls (semi-gloss)

- Door with locking capability

1 1,500 240 2 C/H Student (lunch room) STD Per code

- Painted walls

- Resilient floor coverings

- Kitchen amenities (fridge, microwave, sink/countertop, table, chairs)

- Door with locking capability

1 500 40 2 C/H Admin (lunch room) STD Per code

- Painted walls

- Resilient floor coverings

- Kitchen amenities (fridge, microwave, sink/countertop, table, chairs)

- Door with locking capability

1 500 40 26 C/H Computer Lab 50 STC 1x 2-duplex wall outlet per work station

- Painted walls (semi-gloss)

- Carpet floors

- Window coverings

- Door with locking capability

- RJ45 voice/data jacks

- 26 computer work stations (computers to be supplied by the US Government)

1 500 40 26 C/H Computer Lab 50 STC 1x 2-duplex wall outlet per work station

- Painted walls (semi-gloss)

- Carpet floors

- Window coverings

- Door with locking capability

- RJ45 voice/data jacks

1 500 2 C/H Conference Room (staff) 50 STC Per code

- Painted walls (semi-gloss)

- Carpet floors

- Window coverings

- Door with locking capability

- RJ45 voice/data jacks

1 1,000 2 C/H Conference Room 50 STC Per code

- Painted walls (semi-gloss)

- Carpet floors

- Window coverings

- Door with locking capability

- RJ45 voice/data jacks

2 2,000 18 2 C/H Physics Lab 50 STC 1x 2-duplex wall outlet every 8-10 feet

- Painted walls (semi-gloss)

- Carpet floors

- Window coverings

- Door with locking capability

- RJ45 voice/data jacks

- Sink

SFO LI-14174, Amendment No. 7

Maximum Occupants

Network Drops Partition Height (C/H=Ceiling) or (S/S=Slab)

Intended use Wall STC Rating 110V Duplex Outlets

Notes / Other Requirements

1 1,400 12 2 C/H Shop area 50 STC Per code

- Painted walls (semi-gloss)

- Window coverings

- Door with locking capability

- RJ45 voice/data jacks

- 220v outlet

- Overhead projector and screen w/ ceiling power connection.

- Glass board

- Sound system

- Dimmable light switches

- Area for US Government to install two (2) smart touch boards w/ wall power connection.

- Two (2) entrances/exits

1 400 12 2 C/H Shop area 50 STC Per code

- Painted walls (semi-gloss)

- Window coverings

- Door with locking capability

- RJ45 voice/data jacks

- 220v outlet

- Overhead projector and screen w/ ceiling power connection.

- Glass board

- Sound system

- Dimmable light switches

- Area for US Government to install two (2) smart touch boards w/ wall power connection.

- Two (2) entrances/exits

1 500 12 2 C/H Shop area 50 STC Per code

- Painted walls (semi-gloss)

- Window coverings

- Door with locking capability

- RJ45 voice/data jacks

- 220v outlet

- Overhead projector and screen w/ ceiling power connection.

- Glass board

- Sound system

- Dimmable light switches

- Area for US Government to install two (2) smart touch boards w/ wall power connection.

- Two (2) entrances/exits

SFO LI-14174, Amendment No. 7

Maximum Occupants

Network Drops Partition Height (C/H=Ceiling) or (S/S=Slab)

Intended use Wall STC Rating 110V Duplex Outlets

Notes / Other Requirements

1 600 12 2 C/H Shop/Lab 50 STC Per code

- Painted walls (semi-gloss)

- Window coverings

- Door with locking capability

- RJ45 voice/data jacks

- 220v outlet

- Overhead projector and screen w/ ceiling power connection.

- Glass board

- Sound system

- Dimmable light switches

- Area for US Government to install two (2) smart touch boards w/ wall power connection.

- Two (2) entrances/exits

1 650 12 2 C/H Shop/Lab 50 STC Per code

- Painted walls (semi-gloss)

- Window coverings

- Door with locking capability

- RJ45 voice/data jacks

- 220v outlet

- Overhead projector and screen w/ ceiling power connection.

- Glass board

- Sound system

- Dimmable light switches

- Area for US Government to install two (2) smart touch boards w/ wall power connection.

- Two (2) entrances/exits

1 1,250 12 2 C/H Shop/Lab 50 STC Per code

- Painted walls (semi-gloss)

- Window coverings

- Door with locking capability

- RJ45 voice/data jacks

- 220v outlet

- Overhead projector and screen w/ ceiling power connection.

- Glass board

- Sound system

- Dimmable light switches

- Area for US Government to install two (2) smart touch boards w/ wall power connection.

- Two (2) entrances/exits

SFO LI-14174, Amendment No. 7

Maximum Occupants

Network Drops Partition Height (C/H=Ceiling) or (S/S=Slab)

Intended use Wall STC Rating 110V Duplex Outlets

Notes / Other Requirements

2 5,000 12 2 C/H Shop/Lab 50 STC Per code

- Painted walls (semi-gloss)

- Window coverings

- Door with locking capability

- RJ45 voice/data jacks

- 220v outlet

- Overhead projector and screen w/ ceiling power connection.

- Glass board

- Sound system

- Dimmable light switches

- Area for US Government to install two (2) smart touch boards w/ wall power connection.

- Two (2) entrances/exits

1 50 12 2 C/H Shop/Lab 50 STC Per code

- Painted walls (semi-gloss)

- Window coverings

- Door with locking capability

- RJ45 voice/data jacks

- 220v outlet

- Overhead projector and screen

- Glass board

- Sound system

- Dimmable light switches

- Area for US Government to install two (2) smart touch boards w/ wall power connection.

- Two (2) entrances/exits

1 1,000 2 C/H Storage STD Per code 3 1,500 2 C/H Storage STD Per code 4 1,000 2 C/H Storage STD Per code 5 500 2 C/H Storage STD Per code

1 980 12 2 S/S Woodshop 60+ STC 1x 2-duplex wall outlet every 8-10 feet

- RJ45 voice/data jacks

- HEPA filtration

1 150 1 0 C/H Expressing station STD Per code - Sink/countertop, love seat, chair

- Door with locking capability

1 0 C/H Male restroom STD Per code 13 stalls, 15 urinals 1 0 C/H Female Restroom STD Per code 12 stalls

1 500 1 C/H Data closet STD 2x 4duplex outlets

1 500 2 C/H Data closet STD 2x 4duplex outlets

52,680 260

General Notes:

Government requires FF&E to be provided by Lessor.

Preferred to have 300 dedicated parking spaces.

SFO LI-14174, Amendment No. 7

Maximum Occupants

Network Drops Partition Height (C/H=Ceiling) or (S/S=Slab)

Intended use Wall STC Rating 110V Duplex Outlets

Notes / Other Requirements

Offerors may propose multiple buildings/facilities to meet the total space requirement captured in above. Buildings/facilities offered meeting the total space requirement must be located on the same property and not exceed a distance of 500 meters from each other.

Requirements B & C are preferred to be co-located, but okay if separate.

SFO LI-14174, Amendment No. 7

Maximum Occupants

Network Drops Partition Height (C/H=Ceiling) or (S/S=Slab)

Intended use Wall STC Rating 110V Duplex Outlets

Notes / Other Requirements

1 500 8 3/ea C/H Office 45 STC 2x 4duplex outlets

- RJ45 voice/data jacks

- Painted walls (semi-gloss)

- Carpeted floors

- Window Coverings

- Door with locking capability

1 26,400 60 0 S/S Open workspace STD 1x 2-duplex wall outlet every 8-10 feet

- 20' ceiling

- One (1)1 large roll-up door to facilitate pallet and (powered) hand truck movements

- Multiple machines requiring 208/230v 100-150amp service.

- Multiple overhead 110v services needed to support work cells (i.e. sewing machines).

1 10,000 4 0 S/S Storage STD Per code

- Open laydown area of 6,00SF

- (300) 4 x 4 x 4 pallets to be stored. Currently stored on (26) 4' x 12' shelving racks and 6 vertical storage systems (10'h x 4'w x 9'l).

- 6,000 sq/ft of open floor for bulk storage.

- One (1) larger roll-up door to facilitate pallet and (powered) hand truck movements

2 800 16 2 C/H Classroom 50 STC Per code

- RJ45 voice/data jacks

- Painted walls (semi-gloss)

- Carpeted floors

- Window Coverings

- Door with locking capability

1 1,250 2 1 S/S Enclosed workspace 50 STC Per code

Space must be able to accommodate a large table CAD machine, can be adjacent or located within the 26,400SF open workspace.

The CAD machine will be supplied by the Navy.

1 560 2 1 S/S Enclosed workspace 50 STC Per code

Space must be able to accommodate a large table CAD machine, can be adjacent or located within the 26,400SF open workspace.

The CAD machine will be supplied by the Navy.

1 900 0 C/H Locker area/room STD Per code 96 lockers

Requirement C: Approximately 45,010 SQFT of Administrative & Classroom Space to Accommodate 92 Personnel

SFO LI-14174, Amendment No. 7

Maximum Occupants

Network Drops Partition Height (C/H=Ceiling) or (S/S=Slab)

Intended use Wall STC Rating 110V Duplex Outlets

Notes / Other Requirements

1 500 2 C/H Conference Room STD Per code

- Minimum 16 chairs and corresponding large table(s)

- RJ45 voice/data jacks

- Painted walls (semi-gloss)

- Carpeted floors

- Window Coverings

- Door with locking capability

1 1,200 0 C/H Break/Lunch Room STD Per code

- Suitable for ~60 (max) day/per shift

- Painted walls

- Resilient floor coverings

- Kitchen amenities (fridge, microwave, sink/countertop, table, chairs)

- Room for 2 vending machines

- Door with locking capability

1 150 1 0 C/H Expressing station STD Per code - Sink/countertop, love seat, chair

- Door with locking capability

1 1,000 0 C/H Male restroom STD Per code 1 750 0 C/H Female Restroom STD Per code

1 1,000 0 C/H Data closet STD 2x 4duplex outlets

45,010 92

General Notes:

Government requires FF&E to be provided by Lessor.

Preferred to have 100 dedicated parking spaces.

Requirements B & C are preferred to be co-located, but okay if separate.

SFO LI-14174, Amendment No. 7

No.

Rooms

Approx. Total Area (SF) Gross

Maximum Occupants

Partition Height (C/H=Ceiling) or (S/S=Slab)

Intended use Wall STC Rating 110V Duplex Outlets

Notes / Other Requirements

1 234 1 2 C/H Executive Office 46 SDC Per code

- RJ45 voice/data jacks

- Painted walls (semi-gloss)

- Carpeted floors

- Window Coverings

- Door with locking capability

13 2,028 13 2 C/H Office 45 SDC Per code

13 cubicle workstations with seating and desks.

- RJ45 voice/data jacks

- Painted walls (semi-gloss)

- Carpeted floors

- Window Coverings

- Door with locking capability

74 6,157 74 1 C/H Cubicles STD Per code

- Open floor plan with 74 cubicles provided at 64 SQFT each.

- RJ45 voice/data jack

- Painted walls (semi-gloss)

- Carpeted floors

- Window Coverings

- Door with locking capability

2 1,300 40 2 C/H Conference Room 45 SDC Per code Seating for 20 people per conference room, with a large conference table

1 520 C/H Record Room STD Per code 25 freestanding 3 feet wide vertical file cabinets, mounted appropriately.

1 520 C/H Storage Room STD Per code 20 4' x 8' light duty storage shelving racks for light boxes drills hole to mount

Requirement D: Approximately 11,812 SQFT of Administrative Space to Accommodate 128 Personnel

SFO LI-14174, Amendment No. 7

1 325 C/H Break Room STD Per code

- Painted walls

- Resilient floor coverings

- Kitchen amenities (fridge, microwave, sink/countertop, table, chairs)

- Room for 2 vending machines

- Door with locking capability

1 130 1 C/H Expressing station STD Per code - Sink/countertop, love seat, chair

- Door with locking capability

1 260 C/H Male restroom STD Per code Amount per code 1 260 C/H Female Restroom STD Per code Amount per code

1 78 C/H Data closet STD 2x 4duplex outlets As many as necessary to ensure <300' cable run to all locations

11,812 128

General Notes:

Government requires FF&E to be provided by Lessor.

Preferred to have 128 dedicated parking spaces.

Requirements D & E are preferred to be co-located, but okay if separate.

SFO LI-14174, Amendment No. 7

Approx. Total Area (SF) Gross

Maximum Occupants

Network Drops Partition Height (C/H=Ceiling) or (S/S=Slab)

Intended use Wall STC Rating 110V Duplex Outlets

Notes / Other Requirements

13 2,028 13 2 C/H Single Office 45 SDC Per code

- RJ45 voice/data jacks

- Painted walls (semi-gloss)

- Carpeted floors

- Window Coverings

- Door with locking capability

2 468 2 2 C/H Executive Office 46 SDC Per code

- RJ45 voice/data jacks

- Painted walls (semi-gloss)

- Carpeted floors

- Window Coverings

- Door with locking capability

42 3,494 42 1 C/H Cubicles STD Per code

- Space for 42 cubicles at 64 sqft each

- RJ45 voice/data jack

- Painted walls (semi-gloss)

- Carpeted floors

- Window Coverings

- Door with locking capability

1 650 20 2 C/H Conference Room 45 SDC Per code Large conference table with seating to accommodate 20 personnel.

1 975 30 2 C/H Training Room 46 SDC Per code Seating for 30 people with table rows.

1 325 C/H Break Room STD Per code

- Painted walls

- Resilient floor coverings

- Kitchen amenities (fridge, microwave, sink/countertop, table, chairs)

- Room for 2 vending machines

- Door with locking capability

1 195 C/H Storage Room STD Per code 96 sq/ft racking with affixed to the floor.

1 130 1 C/H Expressing station STD Per code - Sink/countertop, love seat, chair

- Door with locking capability

1 260 C/H Male restroom STD Per code Amount per code 1 260 C/H Female Restroom STD Per code Amount per code

1 78 C/H Data closet STD 2x 4duplex outlets As many as necessary to ensure <300' cable run to all locations

8,863 107

General Notes:

Government requires FF&E to be provided by Lessor.

Preferred to have 107 dedicated parking spaces.

Requirements D & E are preferred to be co-located, but okay if separate.

Requirement E: Approximately 8,863 SQFT of Administrative & Training Space to Accommodate 107 Personnel

SFO LI-14174, Amendment No. 7

Maximum Occupants

Network Drops Partition Height (C/H=Ceiling) or (S/S=Slab)

Intended use Wall STC Rating 110V Duplex Outlets

Notes / Other Requirements

1 107,685 100 10 S/S Warehouse / Work shop STD See notes

- Preferred temperature at 68-72 degrees

- Ground Level Loading Dock for Shipping/Receiving. Loading Dock Bay Doors 20' x 15'.

- Floors must accommodate anchoring of storage racks. Shelves to hold 12,000lbs/per shelf. Minimum floor load 250lbs/SF and no less than 6" thick. Smooth polished and sealed concrete floor.

- (2000) 4 x 4 x 4 pallets to be stored. Currently stored on (210) 4' x 12' shelving racks (Wood pallets with wiring, piping, pumps, electrical cabinets, hoses, lighting, bench testing equipment, breakers).

- Hazmat, Gov to provide proper storage of hazmat materials (solvents, glues, oils, cleaners, antiseize, etc.).

- 77,685 sq/ft floor area must be dedicated for shop repair area and bulk item storage.

- High pressure air 5000 PSI

- Low pressure air 120 PSI

- 2,000Amp 480V 3-phase electrical service

- 240V many locations

- 480V 3-phase many locations

- Potable water many locations

- Drains in several locations

19 2280 19 19 C/H Office STD 2x 4duplex outlets

- RJ45 voice/data jacks

- Painted walls (semi-gloss)

- Carpeted floors

- Window Coverings

- Door with locking capability

Requirement F: Approximately 111,695 SQFT of Warehouse Space to Accommodate Up to 120 Personnel

SFO LI-14174, Amendment No. 7

Maximum Occupants

Network Drops Partition Height (C/H=Ceiling) or (S/S=Slab)

Intended use Wall STC Rating 110V Duplex Outlets

Notes / Other Requirements

1 80 C/H Data closet STD 2x 4duplex outlets

3 750 C/H Break Room STD Per code

- Painted walls

- Resilient floor coverings

- Kitchen amenities (fridge, microwave, sink/countertop, table, chairs)

- Room for 2 vending machines

- Door with locking capability

1 100 1 C/H Expressing station STD Per code - Sink/countertop, love seat, chair

- Door with locking capability

2 400 C/H Male restroom STD Per code Amount per code 2 400 C/H Female Restroom STD Per code Amount per code

111,695 120

General Notes:

Government requires FF&E to be provided by Lessor.

Offerors may propose multiple buildings/facilities to meet the total space requirement captured in above. Buildings/facilities offered meeting the total space requirement must be located on the same property and not exceed a distance of 500 meters from each other.

Preferred to have 80 dedicated parking spaces plus parking for two (2) semis with 40 foot trailers.

SFO LI-14174, Amendment No. 7

Approx. Total Area (SF) Gross

Maximum Occupants

Network Drops Partition Height (C/H=Ceiling) or (S/S=Slab)

Intended use Wall STC Rating 110V Duplex Outlets

Notes / Other Requirements

1 60,000 16 S/S Warehouse STD N/A

- Ground Level Loading Dock for Shipping/Receiving. Loading Dock Bay Doors 15' x 15'.

- Floors must accommodate anchoring of storage racks. Shelves to hold 12,000lbs/per shelf. Minimum floor load 250lbs/SF and no less than 6" thick. Smooth polished and sealed concrete floor.

- Freightliner with 40' trailer accessible.

- (1400) 4 x 4 x 4 pallets to be stored. Currently stored on (140) 4' x 12' shelving racks. Wood pallets used on racks for breakers, small equipment, extra parts.

- Minimum 40,000 sq/ft floor space for bulk equipment storage.

-Preferred to have parking for six (6) people.

NOTES:

1) Must provide facilities for one person to conduct daily warehouse management tasks ( i.e. rest room, area for a work station and connectivity access).

2) No known use of hazmat.

60,000 16

General Notes:

Government requires FF&E to be provided by Lessor.

Offerors may propose multiple buildings/facilities to meet the total space requirement captured in above. Buildings/facilities offered meeting the total space requirement must be located on the same property and not exceed a distance of 500 meters from each other.

Preference is for Requirements G, I & L to be co-located, but okay if separate.

Requirement G: Approximately 60,000 SQFT of Warehouse Space to Accommodate 16 Personnel

SFO LI-14174, Amendment No. 7

Maximum Occupancy

Network Drops Partition Height (C/H=Ceiling) or (S/S=Slab)

Intended use Wall STC Rating 110V Duplex Outlets

Notes / Other Requirements

1 25,000 4 S/S Warehouse STD Per code

- Ground Level Loading Dock for Shipping/Receiving. Loading Dock Bay Doors 16' x 16'.

- 3T & 17T forklift will be used.

- Minimum floor load 250lbs/SF and no less than 6" thick. Smooth polished and sealed concrete floor.

- Semi with 40' trailer accessible

NOTES:

1) This is for storage of equipment only. No production work will be performed, nor will there be full time occupancy by personal.

1 6,000 20 S/S

Work Shop

S/06 - S/71 Machine repair

STD

480V 3 phase 400A

230V 3 phase 100A

240V 100A

120V 100A

200A/400A Disconnect switch

- Preferred temperature of 68-72 degrees.

- Ground Level Loading Dock for Shipping/Receiving. Loading Dock Bay Doors 16' x 16'.

- Floors must accommodate anchoring of storage racks. Shelves to hold 12,000lbs/per shelf. Minimum floor load 250lbs/SF and no less than 6" thick. Smooth polished and sealed concrete floor.

- 3T & 17T forklift will be used.

- Semi with 40' trailer accessible.

- (90) 4 x 4 x 4 pallets to be stored. Currently stored on (10) 4' x 12' shelving racks.

Minimum 5,500 sq/ft floor space for machine repair. Wood pallets used on racks to store.

- 120 PSI air

- Potable water with sink

1 1000 20 4 C/H Office / Muster Area STD Per code

- RJ45 voice/data jacks

- Painted walls (semi-gloss)

- Carpeted floors

- Window Coverings

- Door with locking capability

1 60 C/H Data closet STD 2x 4duplex outlets

1 325 C/H Break Room STD Per code

- Painted walls

- Resilient floor coverings

- Kitchen amenities (fridge, microwave, sink/countertop, table, chairs)

- Room for 2 vending machines

- Door with locking capability

1 130 1 C/H Expressing station STD Per code - Sink/countertop, love seat, chair

- Door with locking capability

1 130 C/H Male restroom STD Per code Per code 1 130 C/H Female Restroom STD Per code Per code

32,775 45

General Notes:

Government requires FF&E to be provided by Lessor.

Preferred to have 45 dedicated parking spaces and one space for a 40 foot semi-truck with a trailer.

Requirement H: Approximately 32,775 SQFT of Warehouse & Industrial Space to Accommodate 45 Personnel

SFO LI-14174, Amendment No. 7

Maximum Occupancy

Network Drops Partition Height (C/H=Ceiling) or (S/S=Slab)

Intended use Wall STC Rating 110V Duplex Outlets

Notes / Other Requirements

The workshop spaces for S/71 will have HAZMAT used in the space.

Storage for HAZMAT will be supplied by the US Government.

SFO LI-14174, Amendment No. 7

Approx. Total Area (SF) Gross

Maximum Occupants

Network Drops Partition Height (C/H=Ceiling) or (S/S=Slab)

Intended use Wall STC Rating 110V Duplex Outlets

Notes / Other Requirements

1 15,000 12 S/S Warehouse STD Per code

- Ground Level Loading Dock for Shipping/Receiving. Loading Dock Bay Doors 15' x 15'.

- Floors must accommodate anchoring of storage racks. Shelves to hold 12,000lbs/per shelf. Minimum floor load 250lbs/SF and no less than 6" thick. Smooth polished and sealed concrete floor.

- Semi with 40' trailer accessible

- 20' ceiling to accommodate 12' shelving systems

- (2100) 4 x 4 x 4 pallets to be stored. Currently stored on (48) 12' roll back racks and (34) - 12' shelving. Will require additional sq/ft if conventional storage is utilized. Wood pallets used on racks for lifting and handling equipment, heavy rollers.

- Preferred to have parking for six (6) people + semi with trailer.

NOTES:

1) This is for storage of equipment only. No production work will be performed, nor will there be full time occupancy by personal.

2) No known use of hazmat.

15,000 12

General Notes:

Government requires FF&E to be provided by Lessor.

Preference is for Requirements G, I & L to be co-located, but okay if separate.

Requirement I: Approximately 15,000 SQFT of Warehouse Space to Accommodate 12 Personnel

SFO LI-14174, Amendment No. 7

Maximum Occupants

Network Drops Partition Height (C/H=Ceiling) or (S/S=Slab)

Intended use Wall STC Rating 110V Duplex Outlets

Notes / Other Requirements

1 12,500 12 S/S Warehouse STD Per code

- Ground Level Loading Dock for Shipping/Receiving. Loading Dock Bay Doors 12' x 12'.

- Floors must accommodate anchoring of storage racks. Shelves to hold 12,000lbs/per shelf

- Minimum floor load 250lbs/SF and no less than 6" thick.

Smooth polished and sealed concrete floor.

- (220) 4' x 4 'x 4' pallets to be stored. Currently stored on (23) 4' x 12' shelving racks.

- Minimum 2,000 sq/ft floor space for bulk storage.

- Wood pallets used on racks to store covered lead.

- Electric forklift (apollolift 1100 or similar)

1 600 12 1 S/S Work Shop STD 4x2-duplex on each wall

- Preferred temperature at 68-72 degrees

- Ground Level Loading Dock for Shipping/Receiving. Loading Dock Bay Doors 12' x 12'.

- Floors must accommodate anchoring of storage racks. Shelves to hold 12,000lbs/per shelf.

- Minimum floor load 250lbs/SF and no less than 6" thick.

Smooth polished and sealed concrete floor.

- (18) 4 x 4 x 4 pallets to be stored. Currently stored on (2) 4' x 12' shelving racks.

- Wood pallets used on racks.

- Gov provided hazmat storage for 20 cans of spray glue and 20 bottles of cleaner.

Requirement J: Approximately 14,525 SQFT of Warehouse Space to Accommodate Approximately 12 Personnel

SFO LI-14174, Amendment No. 7

Maximum Occupants

Network Drops Partition Height (C/H=Ceiling) or (S/S=Slab)

Intended use Wall STC Rating 110V Duplex Outlets

Notes / Other Requirements

1 650 12 2 C/H Office / Muster Area STD Per code

- RJ45 voice/data jacks

- Painted walls (semi-gloss)

- Carpeted floors

- Window Coverings

- Door with locking capability

1 60 C/H Data closet STD 2x 4duplex outlets

1 325 C/H Break Room STD Per code

- Painted walls

- Resilient floor coverings

- Kitchen amenities (fridge, microwave, sink/countertop, table, chairs)

- Room for 2 vending machines

- Door with locking capability

1 130 C/H Expressing station STD Per code - Sink/countertop, love seat, chair

- Door with locking capability

1 130 C/H Male restroom STD Per code Per code 1 130 C/H Female Restroom STD Per code Per code

14,525 12

General Notes:

Government requires FF&E to be provided by Lessor.

Preferred to have 12 dedicated parking spaces.

The Warehouse Room line item (12,500 sq ft) can be split into 2 buildings; however, 1 of those 2 buildings must also contain the muster rooms and restrooms in the same building. The buildings must be within 500 meters, with preference for as close proximity as possible.

Lead is covered in thick herculite material, not exposed to elements. In the work shop, crews will remove lead from protective covers to perform repairs.

SFO LI-14174, Amendment No. 7

Approx. Total Area (SF) Gross

Maximum Occupants

Network Drops Partition Height (C/H=Ceiling) or (S/S=Slab)

Intended use Wall STC Rating 110V Duplex Outlets

Notes / Other Requirements

1 18,200 1 S/S Interior Applied Instruction (Industrial Space)

STD Per code

- 20' ceiling height minimum

- 16' x16' roll up door with convenient access to blast and paint booths.

- Climate Controlled to 65-70 deg F.

- 2ea 14'x18' min Blast Booths (provided by lessor)

- 14'x18' min Paint Booths (provided by lessor)

- All electrical and air services to operate equipment listed in "Equipment relocated from 1187" 120PSI Tool Air 110VAC Outlets Transition to equipment area to run hoses through.

Overall use case: Instructional area for students to perform mock up training with various blast and painting functions.

1 5,460 S/S Equipment Room STD Per code

20' ceiling height minimum Multiple 16' x16' roll up doors 120PSI Tool Air for general use.

110VAC Outlets for general use.

All electrical and air services to operate equipment from "Portable Equipment on Site for Training" list. Disconnects will need to be provided for removal/replacement of equipment.

Directly adjacent to Interior Applied Instruction Building above with pass thru in the wall to get hoses to blast and paint booths.

Area and doors will need to be big enough to install/remove items from "Portable Equipment on Sight for Training" list when repair/service is required.

1 1,950 C/H Training Classroom STD Per code

- RJ45 voice/data jacks

- Painted walls (semi-gloss)

- Carpeted floors

- Window Coverings

- Door with locking capability

- Dimmable light switch

Requirement K: Approximately 30,975 SQFT of Industrial Space to Accommodate 40 Personnel

SFO LI-14174, Amendment No. 7

Approx. Total Area (SF) Gross

Maximum Occupants

Network Drops Partition Height (C/H=Ceiling) or (S/S=Slab)

Intended use Wall STC Rating 110V Duplex Outlets

Notes / Other Requirements

1 520 4 C/H Supervisor Office STD Per code

- RJ45 voice/data jacks

- Painted walls (semi-gloss)

- Carpeted floors

- Window Coverings

- Door with locking capability

1 325 C/H Flam Locker Laydown Space STD Per code Kitchen environment (fridge, microwave, sink/countertop, table, chairs). Room for 2 vending machines.

1 130 C/H Expressing station STD Per code - Sink/countertop, love seat, chair

- Door with locking capability

1 195 C/H Male restroom STD Per code Amount per code 1 195 C/H Female Restroom STD Per code Amount per code

- Lead Showers Five (5) each for men and women.

1,500 Break/Locker Room/Muster Area

- Painted walls

- Resilient floor coverings

- Kitchen amenities (fridge, microwave, sink/countertop, table, chairs)

- Room for 2 vending machines

- Door with locking capability

2,500 Laydown Area Can be interior or exterior.

30,975

General Notes:

Government requires FF&E, paint booths and blast booths to be provided by Lessor.

Preferred to have 40 dedicated parking spaces plus space for one

(1) large shop truck.

SFO LI-14174, Amendment No. 7

Approx. Total Area (SF) Gross

Maximum Occupants

Network Drops Partition Height (C/H=Ceiling) or (S/S=Slab)

Intended use Wall STC Rating 110V Duplex Outlets

Notes / Other Requirements

1 7,000 3 S/S Warehouse STD Per code

- Ground Level Loading Dock for Shipping/Receiving. Loading Dock Bay Doors 15' x 15'.

- Floors must accommodate anchoring of storage racks. Shelves to hold 12,000lbs/per shelf. Minimum floor load 250lbs/SF and no less than 6" thick. Smooth polished and sealed concrete floor.

- Semi with 40' trailer accessible

- (350) 4 x 4 x 4 pallets to be stored. Currently stored on (36) 4' x 12' shelving racks. Wood pallets used on racks

- Preferred to have parking for six (6) people + semi with trailer.

NOTES:

1) This is for storage of welding equipment only. No production work will be performed, nor will there be full time occupancy by personal.

2) No known use of hazmat.

7,000 3

General Notes:

Government requires FF&E to be provided by Lessor.

Preference is for Requirements G, I & L to be co-located, but okay if separate.

Requirement L: Approximately 7,000 SQFT of Warehouse Space to Accommodate 3 Personnel

SFO LI-14174, Amendment No. 7

Approx. Total Area (SF) Gross

Maximum occupancy

Partition Height (C/H=Ceiling) or (S/S=Slab)

Intended use Wall STC Rating 110V Duplex Outlets

Notes / Other Requirements

1 120,000 S/S Outdoor Storage N/A

- Improved ground suitable for 7 ton forklift. Point load rating of

2,000 LBS.

- Perimeter security fence.

- Freightliner with 40' trailer accessible.

1 650 12 C/H Office / Muster Area STD Per code Preferred to have twelve (12) dedicated parking spaces plus parking for one (1) semi with trailer.

1 60 C/H Data closet STD 2x 4duplex outlets

1 325 C/H Break Room STD Per code

- Painted walls

- Resilient floor coverings

- Kitchen amenities (fridge, microwave, sink/countertop, table, chairs)

- Room for 2 vending machines

- Door with locking capability

1 130 1 C/H Expressing station STD Per code - Sink/countertop, love seat, chair

- Door with locking capability

1 130 C/H Male restroom STD Per code Amount per code 1 130 C/H Female Restroom STD Per code Amount per code

121,425 GSF

General Notes:

Government requires FF&E to be provided by Lessor.

All five (5) laydown Requirements M, N, O, P & Q are preferred to be co-located, but okay if separate.

This is for storage of equipment only. No production work will be performed, nor will there be full time occupancy by personnel.

Requirement M: Approximately 121,425 SQFT of Laydown Space and Accommodate 12 Personnel

SFO LI-14174, Amendment No. 7

Approx. Total Area (SF) Gross

Maximum Occupants

Partition Height (C/H=Ceiling) or (S/S=Slab)

Intended use Wall STC Rating 110V Duplex Outlets

Notes / Other Requirements

1 100,000 S/S Outdoor Storage N/A

- Improved ground suitable for 7 ton forklift. Point load rating of

11,000 LBS.

- Perimeter security fence.

- Freightliner with 40' trailer accessible.

1 650 12 C/H Office / Muster Area STD Per code Preferred to have twelve (12) dedicated parking spaces plus parking for one (1) semi with trailer.

1 60 C/H Data closet STD 2x 4duplex outlets

1 325 C/H Break Room STD Per code

- Painted walls

- Resilient floor coverings

- Kitchen amenities (fridge, microwave, sink/countertop, table, chairs)

- Room for 2 vending machines

- Door with locking capability

1 130 1 C/H Expressing station STD Per code - Sink/countertop, love seat, chair

- Door with locking capability

1 130 C/H Male restroom STD Per code Amount per code 1 130 C/H Female Restroom STD Per code Amount per code

101,425 GSF

General Notes:

Government requires FF&E to be provided by Lessor.

All five (5) laydown Requirements M, N, O, P & Q are preferred to be co-located, but okay if separate.

This is for storage of equipment only. No production work will be performed, nor will there be full time occupancy by personnel.

Requirement N: Approximately 101,425 SQFT of Laydown Space and Accommodate 12 Personnel

SFO LI-14174, Amendment No. 7

Approx. Total Area (SF) Gross

Maximum occupancy

Partition Height (C/H=Ceiling) or (S/S=Slab) Intended use Wall STC Rating

110V Duplex Outlets Notes / Other Requirements

1 60,000 10 S/S Laydown STD N/A

- Improved ground suitable for 10 ton forklift. Point load rating of

8,000 LBS.

- Preferred to have six (6) dedicated parking spaces plus parking for one (1) semi with trailer.

- Portable Restroom & handwashing station (provided by Gov)

- Perimeter security fence

- Freightliner with 40' trailer accessible

- US Government to store connex boxes.

60,000 GSF

General Notes:

Government requires FF&E to be provided by Lessor.

All five (5) laydown Requirements M, N, O, P & Q are preferred to be co-located, but okay if separate.

This is for storage of equipment only. No production work will be performed, nor will there be full time occupancy by personnel.

Requirement O: Approximately 60,000 SQFT of Laydown Space to Accommodate 6 Personnel

SFO LI-14174, Amendment No. 7

Approx. Total Area (SF) Gross

Maximum occupancy

Partition Height (C/H=Ceiling) or (S/S=Slab)

Intended use Wall STC Rating 110V Duplex Outlets

Notes / Other Requirements

1 50,000 S/S Storage STD N/A

- Improved ground suitable for 10 ton forklift. Point load rating of

8,000 LBS.

- Preferred to have six (6) dedicated parking spaces plus parking for one (1) semi with trailer.

- Perimeter security fence

- Freightliner with 40' trailer accessible

50,000 GSF

General Notes:

Government requires FF&E to be provided by Lessor.

All five (5) laydown Requirements M, N, O, P & Q are preferred to be co-located, but okay if separate.

This is for storage of equipment only. No production work will be performed, nor will there be full time occupancy by personnel.

Requirement P: Approximately 50,000 SQFT of Laydown Space to Accommodate 6 Personnel

SFO LI-14174, Amendment No. 7

Approx. Total Area (SF) Gross

Maximum occupancy

Partition Height (C/H=Ceiling) or (S/S=Slab) Intended use Wall STC Rating

110V Duplex Outlets Notes / Other Requirements

1 20,000 S/S Storage STD N/A

- Improved ground suitable for 10 ton forklift. Point load rating of

8,000 LBS.

- Preferred to have six (6) dedicated parking spaces plus parking for one (1) semi with trailer.

- Perimeter security fence

- Freightliner with 40' trailer accessible

- US Government to store connex boxes

20,000 GSF

General Notes:

Government requires FF&E to be provided by Lessor.

All five (5) laydown Requirements M, N, O, P & Q are preferred to be co-located, but okay if separate.

This is for storage of equipment only. No production work will be performed, nor will there be full time occupancy by personnel.

Requirement Q: Approximately 20,000 SQFT of Laydown Space to Accommodate 6 Personnel

SFO LI-14174, Amendment No. 7

Maximum Occupancy

Network Drops Partition Height (C/H=Ceiling) or (S/S=Slab)

Intended use Wall STC Rating 110V Duplex Outlets

Notes / Other Requirements

1 6,000 12 S/S Work Shop

C/350 Demil

STD

4x2-duplex on each wall

480V 3 phase 300A

- Preferred temperature of 68-72 degrees.

- Ground Level Loading Dock for Shipping/Receiving

- Floors must accommodate anchoring of storage racks. Shelves to hold 12,000lbs/per shelf

- 3T forklift will be used, door large enough to support

- Minimum floor load 250lbs/SF and no less than 6" thick

- Smooth polished and sealed concrete floor

- Semi with 40' trailer accessible (outside)

- (45) 4 x 4 x 4 pallets to be stored. Currently stored on (5) 4' x 12' shelving racks.

- Wood pallets used on racks

- Hazmat:, Gov to provide proper storage.

- 120 PSI air

- (4) Wall mounted jib cranes (rated to 3 ton)

- Potable water with sink

- Needs a crew muster area for 12 people

6,000 12

General Notes:

Government requires FF&E to be provided by Lessor.

Preferred to have 12 dedicated parking spaces and one space for a 40 foot semi-truck with a trailer.

The workshop spaces will have HAZMAT used in the space.

Storage for HAZMAT will be supplied by the US Government.

Requirement R: Approximately 6,000 SQFT of Industrial Space to Accommodate 12 Personnel

SFO LI-14174, Amendment No. 7

File details come from the government source that posted it. Updated .