This document is a Request for Proposal (RFP) for a Job Order Contract (JOC) to provide new construction, alterations, maintenance, repair, sustainment, restoration, and modernization services for the U.S. Army Garrison and tenant organizations located at Redstone Arsenal (RSA). The North American Industry Classification System (NAICS) code is 236210 (Industrial Building Construction) with a $45 Million business size standard. The product/service code is C1QA (Architect and Engineering - Construction: Restoration of Real Property). The projected period of performance is 20 June 2025 through 19 June 2030 with a 6-month priced option extension. The contract is a 100% 8(a) small business set-aside acquisition to support the U.S. Army Garrison-Redstone's mission to maintain oversight of construction activities at RSA, including administrative facilities, base support and maintenance shops, childcare centers, fitness centers, vehicle maintenance, food service, public safety, airfield structures, roads, utilities, and research/testing facilities. The work may also include incidental design, testing, studies, and abatement for lead-based paint and asbestos.
View the file
Other files
Show all 44
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WALLS
NUMBER NAME FINISH BASE MATERIAL FINISH HEIGHT SILL CASING COVERING
100 CORRIDOR VCT-1 WB-1 P-1 ACT-1 - 8'-9" - - - 100
101 MECHANICAL ROOM CONCRETE/CS-1 WB-1 P-3 - - - - - - NOTE #1 101
101A ELECTRICAL ROOM CONCRETE/CS-1 WB-1 P-3 - - - - - - NOTE #1 101A
102 EAST HIGH BAY RAF-1 / CPT-1 WB-1 P-1 ACT-1 - 10'-0" - - - 102
103 LAUNDRY VCT-1 WB-1 P-1 ACT-1 - 8'-9" - - - 103
104 BREAK AREA / WORK SHOP CONCRETE/CS-1 WB-1 P-1 ACT-1 - 14'-0" - - - 104
105 WOMEN'S RESTROOM CT-1 CT-2 CT-3/CT-4 ACT-2 - 8'-6" - - - 105
105A WOMEN'S SHOWER CT-1 CT-2 CT-3/CT-4 GYP.BOARD P-2 8'-6" - - - 105A
106 WEST HIGH BAY RAF-1 / CPT-1 WB-1 P-1 ACT-1 - 10'-0" - - - 106
107 JANITOR'S CLOSET VCT-1 WB-1 P-1 - - - - - - 107
108 STORAGE CONCRETE/CS-1 WB-1 P-1 ACT-1 - 14'-0" - - - 108
109 MEN'S RESTROOM CT-1 CT-2 CT-3/CT-4 ACT-2 - 8'-6" - - - 109
109A MEN'S SHOWER CT-1 CT-2 CT-3/CT-4 GYP.BOARD P-2 8'-6" - - - 109A
110 COMMUNICATION ROOM SDT-1 WB-1 P-3 - - - - - - 110
111 OFFICE VCT-1 WB-1 P-1 ACT-1 - 8'-9" SSM-1 - WC-1 111
112 SAPP ROOM SDT-1 WB-1 P-1 ACT-1 - 8'-9" - - - 112
113 OFFICE VCT-1 WB-1 P-1 ACT-1 - 8'-9" SSM-1 - WC-1 113
114 BREAK ROOM VCT-1 WB-1 P-1 ACT-1 - 8'-9" - - - 114
115 OFFICE / STORAGE VCT-1 WB-1 P-1 ACT-1 - 8'-9" - - - 115
NOTES:
1. PRIME COAT ONLY (MECHANICAL & ELECTRICAL ROOMS).
2.
ROOM FINISH SCHEDULE
ROOM FLOOR CEILING
REMARKS NUMBER
WINDOWS
MATERIAL AND FINISH SCHEDULE:
A. ALL PRODUCT NAMES AND MODEL NUMBERS ARE GIVEN FOR ESTIMATING PURPOSES. PRODUCTS EQUAL
TO THOSE SPECIFIED MAY BE USED IF APPROVED BY THE DPW-PM.
B. SUBMIT SAMPLES OF ALL PRODUCTS LISTED IN THE ‘MATERIAL AND FINISH SCHEDULE’ TO THE DPW-PM
FOR APPROVAL. THE SAMPLES SHALL INCLUDE TEXTURE AND COLOR CHARTS FOR SELECTION OF ALL
ITEMS.
CARPET:
CPT-1: J+J FLOORING, JOURNEY 7621, COLOR: "PACE 3347", SIZE: 18"x36", INSTALLED w/ INTERFACE TACTILES AT
CORNERS.
INSTALLATION METHOD: ASHLAR
NOTES:
A. ALL CARPET TILES SHALL HAVE PRE-APPLIED ADHESIVE, UNLESS OTHERWISE NOTED.
B. PROVIDE AND INSTALL VINYL TRANSITION STRIPS AS NECESSARY BETWEEN CARPET AND OTHER
FLOORING MATERIALS, UNLESS OTHERWISE NOTED.
C. ALL CARPET TILES SHALL BE INSTALLED OVER TANDUS, CLOSED-CELL CUSHION, FLEX-AIRE CUSHION D. CARPET ORDERED SHALL INCLUDE AN ADDITIONAL QUANTITY OF 2% FOR GOVERNMENT STORAGE.
VINYL COMPOSITE TILE:
VCT-1: TARKETT, 12"x12", ITEM: PCVT 10516, STYLE: LVT CORTINA GRANDE, COLOR: "GRILLE GREY"
STATIC DISSIPATIVE TILE:
SDT-1: VPI ESD STATIC CONTROL TILE, STATMATE, 24"x24", COLOR: 16_CLOUD, VPI-165 ADHESIVE, 24" GROUNDING
STRIP PER 1000SF REQUIRED
NOTES:
A. SUBSTITUTIONS MUST BE PRE-APPROVED EQUALS.
B. STRICTLY FOLLOW MANUFACTURERS SURFACE PREPARATION AND INSTALLATION RECOMMENDATIONS.
FOLLOWING COMPONENTS MUST BE USED TOGETHER TO OBTAIN THE STATIC DISSIPATIVE PERFORMANCE
REQUIREMENTS:
1. TILE w/ INTEGRAL STATIC DISSIPATIVE ELEMENTS
2. S-202 STATIC DISSIPATIVE ADHESIVE
3. COPPER GROUNDING STRIPS
4. 2-392 STATIC DISSIPATIVE POLISH
WALL BASE:
WB-1: JOHNSONITE, "PERCEPTIONS" RECESS PROFILES, RWDC 20 1/4 X120, 4 1/4"x1/8", CHARCOAL-20, CERAMIC TILE:
CT-1: AMERICAN OLEAN COLORBODY, UNGLAZED PORCELEAN MOSAIC, 2"x2", COLOR: #A06 "STORM GRAY SPECKLED", STRAIGHT JOINT
GROUT: COLOR: STERLING SILVER, 78 GROUT, APPLY SEALER
CT-2: AMERICAN OLEAN COLOR STORY, GLAZED CERAMIC WALL TILE, 4"x4", COLOR: #0025 "BALANCE", FLAT TOP COVE BASE(+ CORNERS) A3401/SCR3401/SCL3401
GROUT: COLOR: BRIGHT WHITE, 22 GROUT, APPLY SEALER, 1/16" GROUT LINE PER MFG
CT-3: AMERICAN OLEAN COLOR STORY, GLAZED CERAMIC WALL TILE , 4"x12", (FIELD)
COLOR: #0034 "MATT BALANCE (MATTE)", BRICK PATTERN, 1/16" GROUT LINE PER MFG
GROUT: COLOR: BRIGHT WHITE, 22 GROUT, APPLY SEALER
CT-4: AMERICAN OLEAN COLOR STORY, GLAZED CERAMIC WALL TILE, 4"x12",(ACCENT- 2 ROWS AT 42" AFF)
COLOR: #0025 "ICE WHITE", BRICK PATTERN, 1/16" GROUT LINE PER MFG
GROUT: COLOR: BRIGHT WHITE, 22 GROUT, APPLY SEALER
NOTES:
A. COMPLETELY CLEAN EXISTING SLAB FROM ANY WAXY OR OILY FILMS AND ANY OTHER DEBRIS OR
OBSTRUCTIONS.
B. GROUT SHALL BE LATICRETE SPECTRALOCK, URETHANE GROUT
C. INSTALL 1/2" WATER RESISTANT PURPLE GYPSUM BOARD IN RESTROOMS, JANITOR CLOSETS, AND CABINET
AREAS IN BREAKROOMS.
D. INSTALL 1/4" CEMENTITIOUS FIBER BOARD ONLY AT SHOWER WALL LOCATIONS WITH CERAMIC OR
PORCELAIN TILE INSTALLED.
E. INSTALL TILE ON WALL BEHIND MIRRORS UNLESS OTHERWISE NOTED.
CONCRETE SEALER:
CS-1: SEALER, CLEAR, NON-GLOSSING, MASONRY AND CONCRETE SEALER, STONE TECHNOLOGIES CONCRETE
SEALER X-2.
NOTES:
i. APPLY TO NEW CONCRETE AFTER CURED TO 80% DESIGN STRENGTH, MINIMUM OF 4 DAYS OF CURING.
ii. NEW CONCRETE THAT CURING COMPOUND WAS APPLIED WHEN PLACED WILL REQUIRE TO BE PRESSURE
WASHED CLEAN PRIOR TO SEALING AS A MINIMUM. ADDITIONAL PREPARATION MAY BE NECESSARY
DEPENDING ON TYPE OF CURING AGENT USED.
iii. EXISTING CONCRETE TO RECEIVE VCT OR CARPET SHALL BE ETCHED OR BEAD BLASTED PRIOR TO
iv. FOLLOW MANUFACTURER'S INSTRUCTIONS FOR APPLICABLE TYPE APPLICATION.
PAINT:
P-1: SHERWIN-WILLIAMS, SATIN FINISH, "SW 7064 PASSIVE"
P-2: SHERWIN-WILLIAMS, SEMI-GLOSS, "SW7067 CITYSCAPE"
P-3: SHERWIN WILLIAMS, SW 7005, PURE WHITE, SEMI-GLOSS (MECH, ELEC, COMM, RISER ROOMS)
STAIN:
S-1: RUST OLEUM , WOOD FINISH, EBONY, 271131, POLYURETHANE FINISH . CONTRACTOR TO SUBMIT SAMPLE
BEFORE STAINING.
ACOUSTICAL CEILING TILE AND GRID:
ACT-1: CERTAIN TEED, BAROQUE, BET-157, 24"x24"x5/8", TRIM EDGE, WHITE, 15/16" GRID ACT-2: CERTAIN TEED, VINYL SHIELD, 24"x24"x5/8", TRIM EDGE, WHITE, 15/16" GRID
NOTES:
A. CEILING GRID SHALL ACCOMMODATE LIGHT FIXTURE LAYOUT. LIGHT FIXTURES SHALL BE CENTERED IN
ROOM, UNLESS OTHERWISE NOTED.
B. CONTRACTORS SHALL INSTALL INITIAL HANGING WIRE FOR CEILING GRID MAINS NO MORE THAN 24” FROM
WALL AT BOTH ENDS THEN INSTALL REMAINING HANGING WIRES PER MANUFACTURER SPECS (TYPICALLY
EVERY 48”).
C. CONTRACTORS SHALL INSTALL CEILING GRID MAINS, IN HALLWAYS AND CORRIDORS, PERPENDICULAR TO THE LENGTH OF THE SPACE. CEILING GRID MAINS SHALL NOT BE INSTALLED RUNNING PARALLEL WITH
THE LONGER AXIS.
SOLID SURFACE MATERIAL:
SSM-1: CORIAN, VENARO WHITE, FOR ALL COUNTERTOPS (BREAKROOM AND RESTROOM COUNTERTOPS, WINDOW
SILLS)
RESTROOM LAVATORIES: CORIAN, DESIGNER WHITE
INTERIOR WALL PANEL:
FRP-1: MARLITE, STANDARD FIBER-REINFORCED PLASTIC WALL PANEL, PEBBLED, P151, LIGHT GRAY
RAISED ACCESS FLOORING:
RAF-1: 24"x24"x12"H. RAISED PANEL SYSTEM, CONCORE 1500 BY TATE OR EQUIVALENT
NOTES:
A. CONTRACTOR SHALL FIELD VERIFY HEIGHT TO MATCH EXISTING FLOOR HEIGHT.
B. ALL SUBSTITUTIONS MUST BE APPROVED PRIOR TO BID OPENING.
WINDOW TREATMENT:
WC-1: LEVOLOR OR EQUAL, 1" ALUM MINI-BLINDS, COLOR: ALABASTER, #112
| 7 AR3 |
| PROJECT PDF SET |
| PROJECT PDF SET.pdf |
| 1 T1 |
| 2 C1 |
| 3 C2 |
| 4 C3 |
| 5 AR1 |
| 6 AR2 |
| 8 AR4 |
| 9 AR5 |
| 10 AR6 |
| 11 AR7 |
| 12 AC1 |
| 13 AC2 |
| 14 AC3 |
| 15 AC4 |
| 16 AC5 |
| 17 PL1 |
| 17 PL2 |
| 18 EL1 |
| 19 EL2 |
| 20 EL3 |
| 22 FP1 |
| 23 FP2 |
| 24 FP3 |
21 EL4