J.7.4 - ECP-MCE-ECC21007-ID-01-CIV-PL-027-E-03.pdf

PDF 440 KB Posted

Attached to
Providencia Island Solar Power Plant Project
Solicitation number
72051423R00004
Issued by

About this file

This document includes a federal contract solicitation and related opportunity details. The solicitation is for the Providencia Island Solar Power Plant Project to construct a 1.8 megawatt peak photovoltaic solar power plant, a 2.5 megawatt hour battery energy storage system, and a power management system to integrate these with Providencia Island's existing diesel generator system in Colombia. The project aims to provide a primary energy source for the island through optimization of generation source integration, interoperability, load oscillation reduction, frequency regulation, and emergency resilience. The battery storage system must deliver a minimum one hour duration at the specified capacity. The US Agency for International Development Colombia is the contracting agency, and the contractor will participate in project development on Providencia Island in the Archipelago of San Andres, Providencia and Santa Catalina, an overseas department of Colombia.

View the file

Other files

File Type Posted
72051423R00004 conformed to mod 04.pdf PDF
72051423R00004 (04).pdf PDF
72051423R00004 (03) List of Changes.pdf PDF
J.7.16 - Ubicacion_Shelter_PMS.pdf PDF
72051423R00004 (03) - Conformed Solicitation (informational).pdf PDF
72051423R00004 (03) Attachments.pdf PDF
J.7.13 - EPC-MCE-ECC21007-ID-01-INS-PL-112.pdf PDF
J.7.14 - ECP-MCE-ECC21007-ID-01-ELE-ET-101.pdf PDF
J.7.15 - Arquitectura_Control_SOPESA.pdf PDF
Providencia QandA.pdf PDF
J.7.1 - HiRes ECP-MCE-ECC21007-ID-01-ELE-PL-48-0-01.pdf PDF
72051423R00004 (02).pdf PDF
72051423R00004 Providencia Solar RFP Attachments.pdf PDF
J.7.5 - ECP-MCE-ECC21007-ID-01-INS-ET-117-B.pdf PDF
72051423R00004 Providencia Solar RFP.pdf PDF
J.7.10 - ECP-MCE-ECC21007-ID-01-INS-ET-155-C.pdf PDF
J.6 Budget Template.xlsx XLSX spreadsheet
J.7.2 - ECP-MCE-ECC21007-ID-01-CIV-PL-027-E-01.pdf PDF
J.7.12 - ECP-21007-IB01-0-INS-ET-003.pdf PDF
J.7.11 - ECP-21007-IB01-0-INS-ET-002.pdf PDF
J.7.3 - ECP-MCE-ECC21007-ID-01-CIV-PL-027-E-02.pdf PDF
J.7.1 - ECP-MCE-ECC21007-ID-01-ELE-PL-48-0-01.pdf PDF
J.7.9 - ECP-MCE-ECC21007-ID-01-INS-ET-157-0.pdf PDF
J.7.6 - EPC-MCE-ECC21007-ID-01-INS-PL-112-4.pdf PDF
J.7.7 - EPC-MCE-ECC21007-ID-01-INS-PL-112-6.pdf PDF
J.2. MME MOU.pdf PDF
J.7.8 - EPC-MCE-ECC21007-ID-01-INS-PL-112-8.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NO

NE

SE

SO

ESPECIFICACIONES OBRAS DE CONCRETO:

CONCRETOS ELABORADOS CON CEMENTOS VERDES :

CONCRETOS DE LIMPIEZA : f'c=17 MPa, 170 kgf/cm², 2500 psi.

CONCRETO CIMENTACIÓN : f'c=21 MPa, 210 kgf/cm², 3000 psi.

TAMAÑO DE AGREGADO GRUESO: Menor a 1".

CARGAS DE DISEÑO:

CARGA VIVA = 2.0 kN/m² CARGA MUERTA = 9.3 kN/m² PRESIÓN DE VIENTO = 1.0 kN/m²

NOTAS GENERALES:

1. LAS MEDIDAS SE DAN EN METROS, A MENOS QUE SE INDIQUE LO CONTRARIO. EL

TRANSFORMADOR DIBUJADO ES ILUSTRATIVO.

2. TODAS LAS MEDIDAS DEBERÁN VERIFICARSE Y AJUSTARSE EN SITIO.

3. LAS JUNTAS ENTRE CONCRETOS EXISTENTES Y NUEVOS DEBERÁN ESTAR LIMPIAS Y

LIBRES DE IMPUREZAS QUE PERJUDIQUEN LA ADHERENCIA, TENDRÁN

RUGOSIDADES DE 7 mm O MAYORES, Y DONDE SE INDIQUE, DEBERÁ USARSE PUENTE

DE ADHERENCIA, SIKADUR 32 PRIMER O EQUIVALENTE.

4. TIEMPO DE CURADO MÍNIMO DE ELEMENTOS NUEVOS: 7 DÍAS.

5. RECUBRIMIENTOS MÍNIMOS:

ZAPATAS Y CIMIENTOS: 75 mm ESTRIBOS DE VIGAS Y PEDESTALES EN CIMENTACIONES: 75 mm REFUERZO PRINCIPAL DE VIGAS Y COLUMNAS: 40 mm REFUERZO PRINCIPAL DE PLACAS Y MUROS: 30 mm

6. ANCLAJES EPÓXICOS, SEGÚN NORMA ASTM C-881-99 TIPO IV GRADO

7. ESTOS PLANOS SE ELABORARON CON BASE EN LOS PLANOS E INFORMACIÓN

SUMINISTRADA POR HMV Y ECOPETROL.

8. PARA EL SISTEMA DE SELLADO DE DUCTOS ANTIROEDORES SE USARÁ UNA

MASILLA ELÁSTICA SELLANTE DE UN COMPONENTE CON BASE EN POLIUTERANO

CON PROCESO DE CURADO EN PRESENCIA DE HUMEDAD EN EL AMBIENTE.

9. VERIFICAR EL ESTRATO PORTANTE EN OBRA.

10. VER DOCUMENTO ECP-MCE-ECC21007-ID-01-CIV-MC-026-A SE ENCUENTRA EL DISEÑO

ESTRUCUTRAL DE LA CIMENTACIÓN TIPO 1: CONTAINER 20 ft Y 15 Ton Y T2:

CONTAINER 20 ft Y 20 Ton

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text

VG-2

AutoCAD SHX Text .40 x .60

AutoCAD SHX Text

VG-2

AutoCAD SHX Text .40 x .60

AutoCAD SHX Text .30 x .40

AutoCAD SHX Text

VG-1

AutoCAD SHX Text .30 x .40

AutoCAD SHX Text

VG-1

AutoCAD SHX Text .30 x .40

AutoCAD SHX Text

VG-1

AutoCAD SHX Text .30 x .40

AutoCAD SHX Text

VG-1

AutoCAD SHX Text B

AutoCAD SHX Text S=0.40 x 0.60

AutoCAD SHX Text Son 2

AutoCAD SHX Text

VG-2

AutoCAD SHX Text 12 E#3

AutoCAD SHX Text c/0.15

AutoCAD SHX Text 2#5=6.15/6.65

AutoCAD SHX Text C

AutoCAD SHX Text 2#5=6.15/6.65

AutoCAD SHX Text

REF. SUPERIOR # 5

AutoCAD SHX Text

REF. INFERIOR # 5

AutoCAD SHX Text E No.3 L=1,70

AutoCAD SHX Text 0,15

AutoCAD SHX Text 0,6

AutoCAD SHX Text 0,4

AutoCAD SHX Text 0,45

AutoCAD SHX Text 0,25

AutoCAD SHX Text

REF. INTERMEDIO# 3

AutoCAD SHX Text A

AutoCAD SHX Text D

AutoCAD SHX Text 12 E#3

AutoCAD SHX Text c/0.15

AutoCAD SHX Text 12 E#3

AutoCAD SHX Text c/0.15

AutoCAD SHX Text Concreto de limpieza e= 5cm

AutoCAD SHX Text Nivel del terreno

AutoCAD SHX Text Viga concreto reforzado 40 X 60cm

AutoCAD SHX Text Viga de carga

AutoCAD SHX Text .40 x .60

AutoCAD SHX Text Viga de amarre

AutoCAD SHX Text .30 x .40

AutoCAD SHX Text .40x.60

AutoCAD SHX Text V-A

AutoCAD SHX Text .40x.60

AutoCAD SHX Text V-B

AutoCAD SHX Text Nivel del terreno

AutoCAD SHX Text

VIGA 2

AutoCAD SHX Text 40X60cm

AutoCAD SHX Text

VIGA 1

AutoCAD SHX Text 30X40cm

AutoCAD SHX Text

AutoCAD SHX Text S=0.30 x 0.40

AutoCAD SHX Text Son 4

AutoCAD SHX Text

VG-1

AutoCAD SHX Text 23 E#3

AutoCAD SHX Text c/0.15

AutoCAD SHX Text 2#5=4.05/4.55

AutoCAD SHX Text

AutoCAD SHX Text 2#5=4.05/4.55

AutoCAD SHX Text E No.3 L=1.10

AutoCAD SHX Text 0,15

AutoCAD SHX Text

REF. SUPERIOR # 5

AutoCAD SHX Text

REF. INFERIOR # 5

AutoCAD SHX Text 0,4

AutoCAD SHX Text 0,3

AutoCAD SHX Text

REF. INTERMEDIO# 3

AutoCAD SHX Text 0,15

AutoCAD SHX Text 0,25

AutoCAD SHX Text

VG-1

AutoCAD SHX Text 30X40cm

AutoCAD SHX Text

VIGA 2

AutoCAD SHX Text 40X60cm

AutoCAD SHX Text

ARCHIPIELAGO DE SAN ANDRÉS, PROVIDENCIA Y SANTA CATALINA

AutoCAD SHX Text

ISLA DE PROVIDENCIA

AutoCAD SHX Text

GRANJA SOLAR PROVIDENCIA

AutoCAD SHX Text

VEREDA SAN FELIPE

AutoCAD SHX Text

ESCALA: 1:50

AutoCAD SHX Text

DESPIECES DE VIGAS

AutoCAD SHX Text

VISTA EN PLANTA

AutoCAD SHX Text

ESCALA: 1:50

AutoCAD SHX Text

LOSA DE CIMENTACIÓN T2

AutoCAD SHX Text A-A

AutoCAD SHX Text

ESCALA: 1:40

AutoCAD SHX Text

CORTE

AutoCAD SHX Text B-B

AutoCAD SHX Text

ESCALA: 1:40

AutoCAD SHX Text

CORTE

AutoCAD SHX Text

ESCALA: 1:25

AutoCAD SHX Text

DETALLE VIGA DE CARGA

AutoCAD SHX Text

ESCALA: 1:20

AutoCAD SHX Text

DETALLE VIGA DE AMARRE

AutoCAD SHX Text

ESCALA: 1:05

AutoCAD SHX Text

DETALLE VG-1

AutoCAD SHX Text

ESCALA: 1:05

AutoCAD SHX Text

DETALLE VG-2

AutoCAD SHX Text FORMATO Pl ( 1000 mm x 700 mm )

AutoCAD SHX Text

ARCHIVO CAD:

AutoCAD SHX Text

NOTAS

AutoCAD SHX Text

LOCALIZACIÓN

AutoCAD SHX Text

CONVENCIONES

AutoCAD SHX Text ECP-MCE-ECC21007-ID-01-CIV-PL-027.dwg

AutoCAD SHX Text

REVISIONES

AutoCAD SHX Text

DIBUJÓ

AutoCAD SHX Text

NOMBRE

AutoCAD SHX Text

ESCALA:

AutoCAD SHX Text

MATRÍCULA

AutoCAD SHX Text

FIRMA

AutoCAD SHX Text

FECHA

AutoCAD SHX Text

REV.

AutoCAD SHX Text

FECHA

AutoCAD SHX Text

DESCRIPCIÓN

AutoCAD SHX Text

DISEÑÓ

AutoCAD SHX Text

REVISÓ

AutoCAD SHX Text

APROBÓ

AutoCAD SHX Text

REV

AutoCAD SHX Text

APROBÓ

AutoCAD SHX Text

DIBUJÓ

AutoCAD SHX Text

DISEÑÓ

AutoCAD SHX Text

REVISÓ

AutoCAD SHX Text No. PLANO:

AutoCAD SHX Text

HOJA:

AutoCAD SHX Text

DE:

AutoCAD SHX Text FORMATO Pl ( 1000 mm x 700 mm )

AutoCAD SHX Text

ARCHIVO CAD:

AutoCAD SHX Text

NOTAS

AutoCAD SHX Text

LOCALIZACIÓN

AutoCAD SHX Text

CONVENCIONES

AutoCAD SHX Text ECP-MCE-ECC21007-ID-01-CIV-PL-027.dwg

AutoCAD SHX Text

REVISIONES

AutoCAD SHX Text

DIBUJÓ

AutoCAD SHX Text

NOMBRE

AutoCAD SHX Text

ESCALA:

AutoCAD SHX Text

MATRÍCULA

AutoCAD SHX Text

FIRMA

AutoCAD SHX Text

FECHA

AutoCAD SHX Text

REV.

AutoCAD SHX Text

FECHA

AutoCAD SHX Text

DESCRIPCIÓN

AutoCAD SHX Text

DISEÑÓ

AutoCAD SHX Text

REVISÓ

AutoCAD SHX Text

APROBÓ

AutoCAD SHX Text

REV

AutoCAD SHX Text

APROBÓ

AutoCAD SHX Text

DIBUJÓ

AutoCAD SHX Text

DISEÑÓ

AutoCAD SHX Text

REVISÓ

AutoCAD SHX Text No. PLANO:

AutoCAD SHX Text

HOJA:

AutoCAD SHX Text

DE:

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text O

AutoCAD SHX Text S

AutoCAD SHX Text

ECP-MCE-ECC21007-ID-01-CIV-PL-027-0

AutoCAD SHX Text

AIA

AutoCAD SHX Text

PLT

AutoCAD SHX Text

ODBM

AutoCAD SHX Text

LCAD

AutoCAD SHX Text

VERSIÓN APROBADA PARA CONSTRUCCIÓN

AutoCAD SHX Text 11-10-2022

AutoCAD SHX Text

AutoCAD SHX Text

AIA

AutoCAD SHX Text

PLT

AutoCAD SHX Text

ODBM

AutoCAD SHX Text

LCAD

AutoCAD SHX Text

VERSIÓN AJUSTADA DE ACUERDO A COMENTARIOS

AutoCAD SHX Text 30-09-2022

AutoCAD SHX Text B

AutoCAD SHX Text

AIA

AutoCAD SHX Text

PLT

AutoCAD SHX Text

ODBM

AutoCAD SHX Text

LCAD

AutoCAD SHX Text

VERSIÓN INICIAL

AutoCAD SHX Text 18-07-2022

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

INDICADA

AutoCAD SHX Text 11-10-2022

AutoCAD SHX Text 091037-0558025

AutoCAD SHX Text

ALFREDO IÑAKI ALEJOS

AutoCAD SHX Text 11-10-2022

AutoCAD SHX Text 25202-124852

AutoCAD SHX Text

PATRICIA LUNA TAMAYO

AutoCAD SHX Text 11-10-2022

AutoCAD SHX Text 25202-339317

AutoCAD SHX Text

DAVID BELTRÁN M.

AutoCAD SHX Text 11-10-2022

AutoCAD SHX Text 91037-0621572

AutoCAD SHX Text

LOURDES AGUDELO D.

AutoCAD SHX Text

CIMENTACIÓN DE EQUIPOS

AutoCAD SHX Text

PLANTA SOLAR FOTOVOLTAICA DE PROVIDENCIA

AutoCAD SHX Text

INGENIERÍA DE DETALLE

AutoCAD SHX Text A-A

AutoCAD SHX Text

ESCALA: 1:25

AutoCAD SHX Text

CORTE

AutoCAD SHX Text

ANCLAJES EPÓXICOS PARA BARRAS CORRUGADAS:

AutoCAD SHX Text REFUERZO : fy=420 MPa, 4200 kgf/cm², 60000 psi

AutoCAD SHX Text

BARRA

AutoCAD SHX Text

%%C PERFORACIÓN

AutoCAD SHX Text Lmin ANCLAJE

AutoCAD SHX Text #3

AutoCAD SHX Text

TENSIÓN MÍNIMA

AutoCAD SHX Text (cm)

AutoCAD SHX Text (mm)

AutoCAD SHX Text (Ton)

AutoCAD SHX Text 10 cm

AutoCAD SHX Text 12 mm

AutoCAD SHX Text

1.8 Ton

AutoCAD SHX Text #4

AutoCAD SHX Text 13 cm

AutoCAD SHX Text 16 mm

AutoCAD SHX Text

2.7 Ton

AutoCAD SHX Text #5

AutoCAD SHX Text 16 cm

AutoCAD SHX Text 19 mm

AutoCAD SHX Text

3.8 Ton

AutoCAD SHX Text #6

AutoCAD SHX Text 20 cm

AutoCAD SHX Text 22 mm

AutoCAD SHX Text

5.2 Ton

AutoCAD SHX Text #7

AutoCAD SHX Text 25 cm

AutoCAD SHX Text 25 mm

AutoCAD SHX Text

6.6 Ton

AutoCAD SHX Text #8

AutoCAD SHX Text 30 cm

AutoCAD SHX Text 28 mm

AutoCAD SHX Text

7.9 Ton

AutoCAD SHX Text

%%UNOMENCLATURA DEL REFUERZO:%%U

AutoCAD SHX Text Cantidad

AutoCAD SHX Text Diámetro en octavos de pulgada

AutoCAD SHX Text Longitud de corte en m.

AutoCAD SHX Text 2#5-6.0 c./.15 B

AutoCAD SHX Text Separación entre barras, en m.

AutoCAD SHX Text CUADRO DE GANCHOS Y TRASLAPOS (f'c=21 MPa)

AutoCAD SHX Text

BARRA

AutoCAD SHX Text

GANCHOS

AutoCAD SHX Text #3

AutoCAD SHX Text (m)

AutoCAD SHX Text 0.15

AutoCAD SHX Text #5

AutoCAD SHX Text 0.25

AutoCAD SHX Text

TRASLAPO

AutoCAD SHX Text (m)

AutoCAD SHX Text 0.45

AutoCAD SHX Text 0.75

Sheets and Views
E-03

File details come from the government source that posted it. Updated .