Lift Station Replacement
Solicitation number
26-CD-033
Issued by
Pinellas County, Florida

About this file

Summary

This is an electrical engineering design document prepared by BCER Engineering for the Pinellas County School Board in Florida, detailing the one-for-one replacement of a lift station at Dixie Hollins High School located at 4940 62nd Street North in St. Petersburg, Florida. The project involves replacing existing lift station power infrastructure while reusing existing conduit to the extent possible. The electrical work includes disconnecting the existing lift station power feeder, removing feeder back to the lift station disconnect switch in the electrical room, and providing a new feeder with three #6 AWG conductors plus one #10 ground conductor from the disconnect in the electrical room to the new lift station location. The new lift station is rated at 208 volts, three-phase, 10 horsepower with a full load amperage of 30.8 amps and a minimum circuit ampacity of 38.5 amps. The project requires replacing existing fuses with 50-amp fuses in the existing fused disconnect and providing fuse reducers to accommodate the 50-amp fuse in the 200-amp disconnect. The bid deadline is 4:00 pm on Monday, August 31, 2026, with bids submitted electronically through the Pinellas County School District e-Procurement Portal at https://procurement.opengov.com/portal/PCSB. The design is dated July 10, 2026, and prepared in compliance with the 2023 Florida Building Code, 2023 Florida Existing Building Code, and NFPA 70-2020 National Electrical Code.

The project specifies that all electrical equipment and materials must be listed or labeled by UL or other recognized testing facilities and installed in accordance with applicable codes. The contractor is responsible for providing permits, inspections, submittals for review, and complete as-built documents within 90 days of certificate of occupancy receipt. The electrical contractor must coordinate with other trades, provide complete and functional systems, and bear responsibility for any costs associated with approved equipment substitutes or field modifications required for coordination. Since this is a one-for-one replacement with no added load, existing electrical infrastructure will be leveraged where possible, with surge protective devices to be added to the existing circuit if not already installed. The contractor must also perform short circuit current calculations and an arc-flash study for the electrical distribution system based on actual installation conditions and utility company parameters.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Issue Record:

Sheet Title:

Sheet no:

Drawn by:

Checked by:

Scale:

Date:

No: Date:Description:

7/10/2026

AS NOTED

BCER PROJECT

6555 N. WICKHAM ROAD, SUITE 104

MELBOURNE, FL 32940 | 321.241.4124

CA# 9303

132325003

© Copyright BCER Engineering

ALL DRAWINGS, SPECIFICATIONS, AND OTHER WORK PRODUCT PREPARED BY BCER

ENGINEERING FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE

PROPERTY OF BCER ENGINEERING. BCER ENGINEERING SHALL RETAIN ALL COMMON LAW,

STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO.

D

IX

IE

H

O

LL

IN

S

H S

LI

FT

ST

AT

IO

N

R

EP

LA

C

EM

EN

T

2n d

St N

St . P et er sb ur g, F

L

JRB

MC

COVER SHEET

CS

LIFT STATION REPLACEMENT

DIXIE HOLLINS HIGH SCHOOL

at

PROJECT NO: 245719

BID AND PERMIT SET July 10, 2026

PREPARED FOR

SCHOOL BOARD OF PINELLAS COUNTY

LAURA HINE - CHAIRPERSON

CAPRICE EDMOND - VICE CHAIRPERSON

KATIE BLAXBERG

LISA N. CANE

STEPHANIE MEYER

DAWN M. PETERS

EILEEN M. LONG

SUPERINTENDENT OF SCHOOLS

KEVEN K. HENDRICK

Sheet List Table Sheet Number Sheet Title

CS COVER SHEET

C1.0 GENERAL NOTES

C2.0 DEMOLITION, UTILITY AND SITE, AND GRADING PLAN

C3.0 SITE DETAILS

C4.0 LIFT STATION DETAILS

E0.01 ELECTRICAL GENERAL INFORMATION

E0.02 ELECTRICAL PROJECT NOTES

ED1.01 ELECTRICAL SITE DEMOLITION PLAN

E1.01 ELECTRICAL SITE PLAN

AutoCAD SHX Text DIMSCALE=1 \\bcercloud\10-projects\132325003\20-production\20-hollinshsliftstationreplacement\hollinshsliftstationreplacement\Sheets\CS COVER SHEET.dwg JUL 8, 2026 6:51AM JBERKEBILE

AutoCAD SHX Text XREFS=(xx-tb-24x36) Layouts=(CS COVER SHEET)

Sheet no:

Drawn by:

Checked by:

Scale:

Date:

No: Date:Description:

7/10/2026

AS NOTED

BCER PROJECT

6555 N. WICKHAM ROAD, SUITE 104

MELBOURNE, FL 32940 | 321.241.4124

CA# 9303

XXXXXXXX

© Copyright BCER Engineering

ALL DRAWINGS, SPECIFICATIONS, AND OTHER WORK PRODUCT PREPARED BY BCER

ENGINEERING FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE

PROPERTY OF BCER ENGINEERING. BCER ENGINEERING SHALL RETAIN ALL COMMON LAW,

STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO.

D

IX

IE

H

O

LL

IN

S

H S

LI

FT

ST

AT

IO

N

R

EP

LA

C

EM

EN

T

2n d

St N

St . P et er sb ur g, F

L

JRB

MC

ELECTRICAL

GENERAL

INFORMATION

E0.01

PROJECT NARRATIVE

PROVIDE POWER FOR ONE-FOR-ONE REPLACEMENT OF LIFT STATION. CONDUIT AND

FEEDERS WILL BE REUSED.

DENVER AND COLORADO SPRINGS OFFICES

14143 DENVER WEST PKWY, SUITE 550

GOLDEN, CO 80401

303.422.7400

TAMPA BAY AND MELBOURNE OFFICES

6555 N. WICKHAM ROAD, SUITE 104

MELBOURNE, FL 32940

321.241.4142

CONTACT LIST

PROJECT ENGINEER / DESIGNER

JOE BERKEBILE

321.355.0297

JBERKEBILE@BCER.COM

PROJECT MANAGER

DAVID WALLACE

727.800.7314

DWALLACE@BCER.COM

ADOPTED/ENFORCED CODES REQUIRED

2023 FLORIDA BUILDING CODE

2023 FLORIDA EXISTING BUILDING CODE

2023 FLORIDA PLUMBING CODE

2023 FLORIDA MECHANICAL CODE

NFPA 70-2020, NATIONAL ELECTRICAL CODE

NFPA 72-2019, NATIONAL FIRE ALARM CODE

TYPICAL DEVICE MOUNTING HEIGHTS

NOTES:

1. DEVICES ABOVE DOORS SHALL BE CENTERED BETWEEN TOP OF DOOR TRIM AND

CEILING LINE.

2. MOUNTING HEIGHTS SHOWN ON ARCHITECTURAL ELEVATIONS SHALL GOVERN

OVER THOSE SHOWN ABOVE.

3. MOUNTING HEIGHTS SHALL BE COORDINATED WITH OTHER DEVICES, ARCHITECT,

AND BE COMPLIANT WITH ADA AND CODE REQUIREMENTS.

T

J

3' -6

4' -0

M

AX

9"

(6 '7

M

AX

9"

(6 '7

P

ER

N

EC

.8

(A

TOP OF OPERABLE DEVICE/HANDLE

FINISHED FLOOR

CENTER OF DEVICE

1' -6

TOP OF OPERABLE DEVICE/HANDLE

CENTER OF DEVICE

VFD

LC

KEYLESS FIXTURE

POLE FIXTURE - BOXROUND DOWNLIGHT

(RECESSED)

SCONCE - CIRCLE/OVAL

EXIT SIGN W/ARROW

BATTERY PACK

BOLLARD FIXTURE

SINGLE-POLE SWITCH

b

C

L

WALL WASH

b

LIGHTING CONTACTOR

W/ NUMBER OF POLES

KEY ON LUMINAIRE

SCHEDULE

SWITCHING

#= DEVICE TYPE

2 = DOUBLE-POLE SWITCH

3 = THREE-WAY SWITCH

4 = FOUR-WAY SWITCH

P = SWITCH AND PILOT LIGHT

K = KEY OPERATED SWITCH

D = DIMMER SWITCH

POLE FIXTURE - PUCK

POLE FIXTURE - COBRA

SQUARE DOWNLIGHT

(SURFACE)

FROGEYE

K

DRUM (PENDANT)

LINEAR FIXTURE

(RECESSED) FLOOD LIGHT

WALL PACK

STRIP FLEXIBLE

CEILING FAN

DUPLEX RECEPTACLE

(CEILING)

SINGLE RECEPTACLE

RACEWAY TURNED UP

LP

EXOTHERMIC CONNECTION

VS

AS AMMETER SELECTOR

SWITCH

AMMETER

VOLTMETER

FUSE AND SWITCH < 600V

FUSE < 600V

CIRCUIT BREAKER < 600V

CAPACITOR

SWITCH AIR BREAK

FUSE > 600V

CABLE TERMINATION

ST

G ENGINE-GENERATOR UNIT

G DIFFERENTIAL RELAY

LOCKOUT RELAY

PRESSURE SWITCH

OVER VOLTAGE RELAY

AC CIRCUIT BREAKER

TIME OVER

CURRENT RELAY

MANUAL SELECTOR

SWITCH

UNDER VOLTAGE RELAY27

OVERHEAD GUY

OVERHEAD LINE

DOWN GUY AND ANCHOR

A

WORK NOTE SYMBOL

ROOM NUMBER220

BATTERY

PAD MOUNTED

TRANSFORMER

GFP

AHU-1

GROUNDING CONDUCTORG

EXTERNAL GROUNDING

BUS BARGROUND ROD

GROUNDING ELECTRODE

PATIENT

GROUNDING POINT

G

QUADPLEX RECEPTACLE

(CEILING)

DUPLEX RECEPTACLE

SPLIT WIRED

PRIMARY FUSE CUTOUT

OIL TYPE

CURRENT TRANSFORMER

W/RATIO

POTENTIAL

TRANSFORMER W/RATIO

VOLTMETER SELECTOR

SWITCH

AUTOMATIC TRANSFER

SWITCH

MANUAL TRANSFER SWITCH

END OF LINE RESISTOR

(EOL)

RED AND GREEN PILOT

LIGHTS

PUSH-BUTTON-NORMALLY

OPEN

CONTACT NORMALLY

OPEN (N.O.)

CONTACT NORMALLY

CLOSED (N.C.)

AMP TRIPAT

MANUAL TRANSFER SWITCHMTS

RELOCATED(R)

CKT

C

CIRCUIT

CONDUIT

ATS

AIC

AF

AFG

AFF

+4'-6"

A/AMP

AMPERE INTERRUPTING

CAPACITY

AMP FRAME

AUTOMATIC TRANSFER SWITCH

ABOVE FINISHED FLOOR

ABOVE FINISHED GRADE

MOUNTING HEIGHT AFF

AMPERE

G GROUND

ENCL

EWC

EPO

EMT

(E)

ELECTRIC METALLIC TUBING

ELECTRIC WATER COOLER

EXISTING

MDS

MH

MDP

MCC

MAIN DISTRIBUTION

SWITCHBOARD

MANHOLE

MAIN DISTRIBUTION PANEL

MOTOR CONTROL CENTER

KW

KVAR

KV

KVA

GRC

HG

KILOWATT

KILOVAR

KILO VOLT-AMPERE

KILOVOLT

GALVANIZED RIGID CONDUIT

PT POTENTIAL TRANSFORMER

RM ROOM

PF

PH

PDU

NO

NC

NIC

N

POWER FACTOR

POWER DISTRIBUTION UNIT

PHASE

NORMALLY CLOSED

NORMALLY OPEN

NOT IN CONTRACT

NEUTRAL

UPS

UG UNDERGROUND

TTB

SW

SCA

TELEPHONE TERMINAL BOARD

SWITCH

WP

WHM

VFD

VDC

VAC

WEATHERPROOF

WATTHOUR METER

VARIABLE FREQUENCY DRIVE

VOLTS DIRECT CURRENT

AC ALTERNATING CURRENT

CP CONTROL PANEL

EC ELECTRICAL CONTRACTOR

FLA FULL LOAD AMPS

LOW VOLTAGELV

MECHANICAL CONTRACTORMC

ac ABOVE COUNTER

REMOVE & RELOCATE(RR)

CURRENT TRANSFORMERCT

UC UNDERCABINET

UF UNDERFLOOR

UNO UNLESS NOTED OTHERWISE

OH

OHG

GROUND FAULT CIRCUIT

INTERRUPTER

HOSPITAL GRADE

VOLTS ALTERNATING CURRENT

UNINTERRUPTIBLE POWER

SUPPLY

EQUIPMENT SCHEDULE

WEATHER HEAD

SERVICE ENTRANCE

SINGLE PHASE

TRANSFORMER: NUMERAL

INDICATES RATING IN KVA

PRIMARY FUSE

CUTOUT AIR TYPE

SWITCH AIR BREAK,

GANG OPERATED

MANHOLE: NUMERAL

INDICATES THE

ASSIGNED NUMBER

AND THE LETTER

INDICATES THE TYPE

PUSH-BUTTON-

NORMALLY CLOSED

OPERATING COIL

(LADDER DIAGRAM)

OPERATING COIL

(SCHEMATIC DIAGRAM)

INSTANTANEOUS OVER

CURRENT RELAY

PANELBOARD

V = VOLTAGE:

L = 208 OR 240

H = 480

S = SPECIAL LOAD:

C = COMPUTER OR

CRITICAL (HC)

E = EMERGENCY OR

EQUIP BRANCH

(HC)

K = KITCHEN

L = LABORATORY OR

LIFESAFETY (HC)

M = MECHANICAL

S = STANDBY

U = UPS

# = FLOOR NUMBER

A = AREA/ZONE

TRANSFORMER (SEE

TRANFORMER SCHEDULE)

CIRCUIT BREAKER WITH

GROUND FAULT

PROTECTIONBREAKER WITH DRAWOUT

FEATURE < 600V

BREAKER WITH DRAWOUT

FEATURE > 600V

FUSED DISCONNECT

SWITCH > 600V

CIRCUIT BREAKER WITH:

ST = SHUNT TRIP

K = KEY INTERLOCKED

E = ELECTRIC OPERATED

LIGHTNING

PROTECTION BARE

CONDUCTOR

SURGE ARRESTER

PLUS GROUND

LIGHTNING PROTECTION

AIR TERMINAL

GROUND ROD WITH

INSPECTION WELL

WR WEATHER RESISTANT

SPD

NL NIGHT LIGHT

TR TAMPER RESISTANT

ALL SYMBOLS IN LEGEND MAY NOT NECESSARILY BE USED ON THIS PROJECT

ABBREVIATIONS AND DESCRIPTIONS

ONE-LINE DIAGRAMS

GROUNDING/LIGHTNING

ELECTRICAL LEGEND

POWER

LIGHTING AND LIGHTING CONTROLS

(D) DEDICATED

ARC FAULT CIRCUIT

INTERRUPTER

AFCI

AHJ AUTHORITY HAVING

JURISDICTION

AUTO AUTOMATIC

CL CENTER LINE

COMM COMMUNICATION

DAS DISTRIBUTED

ANTENNA SYSTEM

DB DECIBAL

DISC DISCONNECT

EOR ENGINEER OF RECORD

EMERGENCY NPOWER OFF

ENCLOSURE

FC FOOTCANDLE

F FUSE

FF FURNITURE FEED

FS FIRE SUPPRESION

HORSEPOWERHP

HIGH PRESSURE SODIUMHPS

HOURHR

HIGH VOLTAGEHV

HERTZHZ SHORT CIRCUIT CURRENT

AVAILABLE

GF GAS FIREPLACE

IMC INTERMEDIATE METAL CONDUIT

SURGE PROTECTIVE DEVICE

TO BE DEMOLISHED WORK IS

SHOWN AS BOLD DASHED LINES

FEEDER SCHEDULE

REVISION NUMBER

MOTOR STARTER OF

CONTACTOR

ENCLOSED FUSED

DISCONNECT SWITCH

ENCLOSED DISCONNECT

SWITCH

ENCLOSED CIRCUIT

BREAKER

VFD

MOTOR

MANUAL PUSHBUTTON

PHOTOCELL

TIME CLOCK

METER

COMBINATION MOTOR

STARTER

SURGE PROTECTOR DEVICE

TAP, SPLICE, LUG OR

CONNECTION

M

VFD

CB

M

TC

ELEC ELECTRICAL

AL ALUMINUM

ARCH

APPROX APPROXIMATE

ARCHITECT

CB CIRCUIT BREAKER

CLG CEILING

COPPERCU

(F) FUTURE

GFP GROUND FAULT PROTECTION

GND GROUND

GD GARBAGE DISPOSAL

GC GENERAL CONTRACTOR

GEN GENERATOR

GEC

AWG AMERICAN WIRE GAUGE

DPDT DOUBLE POLE DOUBLE THROW

DPST DOUBLE POLE SINGLE THROW

DWG DRAWING

DW DISHWASHER

P POLE

PLC PROGRAMMABLE LOGIC

CONTROLLER

PNL PANEL

HH HAND HOLE

HC HEALTH CARE

HOA HAND-OFF-AUTOMATIC

HID HIGH INTENSITY DISCHARGE

NEW WORK IS SHOWN AS BOLD

SOLID LINES

(N) NEWø PHASE

N

E-5

NTS NOT TO SCALE

CONTINUATION

CAP

RACEWAY TURNED DOWN

DUPLEX RECEPTACLE

(FLOOR)

DUPLEX RECEPTACLE

(WALL)

QUADPLEX RECEPTACLE

(FLOOR)

QUADPLEX RECEPTACLE

(WALL)

DUPLEX RECEPTACLE/

SWITCH COMBINATION

TO

30/3 30A

BUZZER (CEILING)

HORN (CEILING)

BELL (CEILING)

SOLENOID (LOW VOLTAGE)

RELAY (LOW VOLTAGE)

TIME CLOCK

THERMOSTAT (LINE VOLTAGE)

MOTOR

PULL BOX

ELECTRIC DAMPER

THERMAL OVERLOAD

SWITCH

M S

SEAL OFF

FEEDER BUS DUCT

6(C)18

UG

W

EXTENSION WHIP

MDS, MCC, CP OR OTHER

EQUIPMENT ENCLOSURE

MULTI-OUTLET ASSEMBLY

OR SURFACE RACEWAY

# = QUANTITY OF REC

*=SPACING IN INCHES OC

MANUAL MOTOR STARTER

DISCONNECT W/SIZE -

CIRCUIT BREAKER

DISCONNECT SWITCH

W/SIZE - FUSED

MOTOR STARTER

OR CONTACTOR

MOTOR STARTER /

DISCONNECT SWITCH

COMBINATION

CABLE TRAY WITH

DEPTH/LOAD/WIDTH

CONCEALED RACEWAY

S = SURFACE

UF = UNDERFLOOR

UG = UNDERGROUND

W = WIREWAY

UF

SPECIAL PURPOSE

RECEPTACLE (CEILING)

SPECIAL PURPOSE

RECEPTACLE (FLOOR)

SPECIAL PURPOSE

RECEPTACLE (WALL)

GROUND FAULT CIRCUIT

INTERRUPTER RECEPTACLE J #M*

OC ON-CENTER

JUNCTION BOX (CEILING)

JUNCTION BOX (FLOOR)

JUNCTION BOX (WALL)

BLANKED FACE DEVICE

(GFCI, AFCI, ETC.)

BRANCH CIRCUIT

PANELBOARD

MAIN DISTRIBUTION

PANEL OR SWITCHBOARD

MECHANICAL EQUIPMENT

J-BOX WITH MANUAL

MOTOR STARTERJ

M

BUZZER (WALL)

HORN (WALL)

BELL (WALL)

VFD VARIABLE-FREQUENCY

DRIVE

DISCONNECT SWITCH

W/SIZE - NON-FUSED30/3

PB

CB

M

M

B

J

J

J

R

S

T

TC

GENERATOR

T

METER

TRANSFORMER

G

M

PUSH BUTTON

OCPD OVERCURRENT PROTECTIVE

DEVICE

OFCI OWNER FURNISHED,

CONTRACTOR INSTALLED

JB JUNCTION BOX

GFCI

EXISTING WORK IS SHOWN AS

LIGHT LINES

GROUNDING ELECTRODE

CONDUCTOR

ILLUMINATING ENGINEERING

SOCIETY

IES

KCMIL KILO CIRCULAR MILS

K KILO (ONE-THOUSAND)

KWH KILOWATT-HOURS

LCD LIGHTING CONTROL DEVICE

LCP LIGHTING CONTROL PANEL

LED LIGHT EMITTING DIODE

LF LLINEAR FOOT

LOH LOCK-ON HANDLE

LRA LOCEKD ROTOR AMPS

LTG LIGHTING

MAXIMUMMAX

MCB MAIN CIRCUIT BREAKER

MCA MINIMUM CIRCUIT AMPACITY

MCM THOUSANDS OF

CIRCULAR MILLS

MFS MAXIMUM FUSE SIZE

MECH MECHANICAL

MIN MINIMUM

MLO MAIN LUG ONLY

MOCP MAXIMUM OVERCURRENT

PROTECTION

MTD MOUNTED

SWBD SWITCHBOARD

SWGR SWITCHGEAR

SYM SYMMETRICAL

TBD TO BE DETERMINED

TECH TECHNOLOGY

TELE TELEPHONE

TEMP TEMPERATURE OR

TEMPORARY

MW MICROWAVE OVEN

NA NOT APPLICABLE

NEC NATIONAL ELECTRICAL CODE

NEMA NATIONAL ELECTRICAL

MANUFACTURERS ASSOCIATION

NM NON-METALLIC

PVC POLYVINYL CHLORIDE

REC RECEPTACLE

REF REFERENCE OR REFRIGERATOR

RGS RIGID GALVANIZED STEEL

RLA RATED LOAD AMPS

REQ REQUIRED

RIGID NON-METALLIC CONDUITRNC

RIGID METAL CONDUITRMC

SEC SECONDARY

SF SQUARE FOOT

SPEC SPECIFICATION

STD STANDARD

ST SHUNT TRIP

TV TELEVISION

TYP TYPICAL

W WATT, WIRE OR WASHER

W/ WITH

W/D WASHER/DRYER

W/O WITHOUT

XFMR TRANSFORMER

UNIVERSAL SERIAL BUSUSB

VOLT AMPEREVA

BREAK LINE

4WG100

NUMBER DESIGNATES DETAIL

SHEET DETAIL IS LOCATED

POINT OF CONNECTION

NEW TO EXISTING

NORTH ARROW

RECTANGLE FIXTURE

(SURFACE)

ROUND DOWNLIGHT

(EMERGENCY)

LINEAR FIXTURE (WALL)

LINEAR FIXTURE

(SURFACE/PENDANT)

SQUARE FIXTURE

(SURFACE)

SQUARE FIXTURE

(RECESSED)

LINEAR FIXTURE

(EMERGENCY)

SQUARE FIXTURE

(EMERGENCY)

A

RECTANGLE FIXTURE

(RECESSED)

RECTANGLE FIXTURE (WALL)

RECTANGLE FIXTURE

(EMERGENCY)

SQUARE FIXTURE (WALL)

B

TRACK LIGHTING

SCONCE -

SQUARE/RECTANGLE

SQUARE DOWNLIGHT

(RECESSED)

UNDER CABINET

STRIP FIXTURE

ROUND DOWNLIGHT

(RECESSED)

SQUARE DOWNLIGHT

(EMERGENCY)DRUM (EMERGENCY)

P

SPD

P TRANSFORMER FEEDER

(PRIMARY)

S TRANSFORMER FEEDER

(SECONDARY)

G TRANSFORMER FEEDER

(GROUND)

T

PNL

LOAD BREAK ELBOW

SEPARABLE CONNECTION

R

C

T

A

V

EXTERNAL GROUNDING BUS

BAR

ELECTRICAL EQUIPMENT

ENCLOSURE

OS OS = OCCUPANCY SENSOR

MD = MOTION DETECTOR

TC = TIME CLOCK

Sheet List Table

Sheet Number Sheet Title

E0.01 ELECTRICAL GENERAL INFORMATION

E0.02 ELECTRICAL PROJECT NOTES

ED1.01 ELECTRICAL SITE DEMOLITION PLAN

E1.01 ELECTRICAL SITE PLAN

This item has been electronically signed and sealed by Robert M. Cordero on the date adjacent to the seal using a SHA authentication code.

Printed copies of this document are not considered signed and the SHA authentication code must be verified on any electronic copies.

Sheet no:

Drawn by:

Checked by:

Scale:

Date:

No: Date:Description:

7/10/2026

AS NOTED

BCER PROJECT

6555 N. WICKHAM ROAD, SUITE 104

MELBOURNE, FL 32940 | 321.241.4124

CA# 9303

XXXXXXXX

© Copyright BCER Engineering

ALL DRAWINGS, SPECIFICATIONS, AND OTHER WORK PRODUCT PREPARED BY BCER

ENGINEERING FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE

PROPERTY OF BCER ENGINEERING. BCER ENGINEERING SHALL RETAIN ALL COMMON LAW,

STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO.

D

IX

IE

H

O

LL

IN

S

H S

LI

FT

ST

AT

IO

N

R

EP

LA

C

EM

EN

T

2n d

St N

St . P et er sb ur g, F

L

JRB

MC

ELECTRICAL

PROJECT NOTES

E0.02

1. REFER TO ELECTRICAL GENERAL INFORMATION SHEET FOR LEGEND AND

ADDITIONAL INFORMATION APPLICABLE TO THE PROJECT.

2. REFER TO THE ELECTRICAL SPECIFICATIONS AND DETAILS FOR ADDITIONAL

INSTALLATION REQUIREMENTS. DRAWINGS AND SPECIFICATIONS ARE

COMPLIMENTARY. WHATEVER IS CALLED FOR IN EITHER IS BINDING AS THOUGH

CALLED FOR IN BOTH. SHOULD DRAWINGS AND SPECIFICATIONS DIFFER IN WHAT IS

REQUIRED, THE STRICTER REQUIREMENT SHALL APPLY UNLESS WRITTEN

CLARIFICATION IS OBTAINED FROM THE ENGINEER TO GO WITH THE LESSOR

REQUIREMENT.

3. THE EQUIPMENT SPECIFIED ON THE DRAWINGS HAS BEEN SELECTED AS THE BASIS

OF DESIGN. THE USE OF REVIEWED OR SPECIFIED EQUALS SHALL BE

COORDINATED BY THE CONTRACTOR AS TO SPACE REQUIREMENTS, EQUIPMENT

DIMENSIONS, AND PERFORMANCE. ANY ADDITIONAL COSTS EITHER DIRECTLY OR

INDIRECTLY CAUSED BY EQUALS SHALL BE THE RESPONSIBILITY OF THE

CONTRACTOR.

4. DRAWINGS ARE DIAGRAMMATIC AND SHOW THE GENERAL DESIGN INTENT,

ARRANGEMENT AND EXTENT OF SYSTEMS. DO NOT SCALE DRAWINGS NOR USE AS

SHOP DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF EXACT

ROUTING OF ALL SERVICES WITH ALL OTHER TRADES. WHERE ALTERNATE

ROUTING, OFFSETS, AND TRANSITIONS ARE REQUIRED FOR FIELD COORDINATION

OF ALL TRADES, THIS CONTRACTOR SHALL MAKE CHANGES WITHOUT ADDITIONAL

COSTS.

5. PROVIDE ELECTRICAL EQUIPMENT, INSTALL, AND SUPPORT IN COMPLIANCE WITH

SEISMIC, WIND LOAD, SNOW LOAD, SOIL CONDITIONS AND OTHER CRITERIA FOR

PROJECT SITE. REFER TO CIVIL, STRUCTURAL OR OTHER PROJECT DOCUMENTS

FOR DEFINITION OF SUCH CRITERIA FOR PROJECT SITE.

6. CONTRACTOR'S FAILURE TO ORDER OR RELEASE ORDER FOR MATERIALS AND/OR

EQUIPMENT IN A TIMELY MANNER WILL NOT BE ACCEPTED AS A REASON TO

SUBSTITUTE ALTERNATE MATERIALS, EQUIPMENT, OR INSTALLATION METHODS.

7. ALL ELECTRICAL SYSTEM COMPONENTS SHALL BE LISTED OR LABELED BY UL OR

OTHER RECOGNIZED TESTING FACILITY.

8. ALL ELECTRICAL SYSTEMS INCLUDING WORK, MATERIALS, AND EQUIPMENT SHALL

BE INSTALLED IN ACCORDANCE WITH THE CODES LISTED ON THE GENERAL

INFORMATION SHEET, THE ARCHITECTURAL CODE PLAN, AND THOSE ADOPTED BY

THE AUTHORITY HAVING JURISDICTION.

9. PROVIDE PERMITS AND INSPECTIONS REQUIRED.

10. PROTECT ELECTRICAL EQUIPMENT THROUGHOUT CONSTRUCTION.

11. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S

APPROVED WIRING DIAGRAMS, DETAILS, AND INSTRUCTIONS UNLESS SPECIFICALLY

DIRECTED OTHERWISE. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO

PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE WITH EQUIPMENT ACTUALLY

SUPPLIED. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING EQUIPMENT

WHICH IS DAMAGED DUE TO INCORRECT FIELD WIRING PROVIDED UNDER THIS

SECTION, OR FACTORY WIRING IN EQUIPMENT PROVIDED UNDER THIS SECTION.

12. SYSTEMS SHALL BE COMPLETE, OPERABLE, AND READY FOR CONTINUOUS

OPERATION PRIOR TO FINAL PUNCH. LIGHTS, SWITCHES, RECEPTACLES, MOTORS,

ETC. SHALL BE CONNECTED, PROGRAMMED, AND OPERABLE. SYSTEMS SHALL BE

TESTED FOR PROPER OPERATION. IF CONTRACTOR'S TESTS SHOW THAT WORK IS

DEFECTIVE, CONTRACTOR SHALL MAKE CORRECTIONS NECESSARY AT NO COST TO

OWNER PRIOR TO FINAL PUNCH.

13. CONTRACTOR SHALL PROVIDE SUBMITTALS ON ITEMS LISTED IN THE ELECTRICAL

SCHEDULES AND AS REQUIRED IN SPECIFICATIONS TO THE ENGINEER FOR REVIEW

PRIOR TO THE ORDER, PURCHASE, OR INSTALLATION OF THESE SAME ITEMS.

SUBMITTALS SHALL INCLUDE, BUT NOT BE LIMITED TO LIGHTING FIXTURES, LIGHTING

CONTROLS, SWITCHGEAR, SWITCHBOARDS, PANELBOARDS, WIRING DEVICES,

SAFETY SWITCHES, FUSES, MOTOR STARTERS, CONDUIT, CONDUIT FITTINGS,

BUILDING WIRE AND CABLE, AND TRANSFORMERS.

14. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATION AND INSTALLATION OF

SLEEVES, INSERTS AND SUPPORTS AS REQUIRED FOR THIS SCOPE OF WORK

AND/OR ANY CORE DRILLING. X-RAY THE FLOOR PRIOR TO CORE DRILL UNLESS

NOTED OTHERWISE. COORDINATE WITH G.C. AND STRUCTURAL ENGINEER AS

REQUIRED.

15. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL FLOORS, TOPPING SLABS,

CONCRETE SHEAR WALLS, OR CONCRETE FLOOR BEAMS OR JOISTS UNLESS

SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE

STRUCTURAL ENGINEER. TOP OF CONDUIT TO BE 12" MINIMUM CLEAR FROM

BOTTOM OF JOISTS. DO NOT DAMAGE REINFORCING BARS.

16. PROTECT STRUCTURE AND OWNER EQUIPMENT FROM DAMAGE. IMMEDIATELY

REPLACE OR REPAIR, TO ORIGINAL CONDITION, DAMAGE CAUSED BY THE

CONTRACTOR WHETHER EQUIPMENT APPEARS TO BE CURRENTLY IN USE OR NOT,

UNLESS WRITTEN AUTHORIZATION IS OBTAINED FROM THE OWNER INDICATED

OTHERWISE. PREPARE LISTING OF ALL EXISTING DAMAGED ITEMS AND SUBMIT TO

OWNER PRIOR TO BEGINNING WORK.

17. ALL PENETRATIONS OF FIRE RATED PARTITIONS DUE TO THE INSTALLATION OR

REMOVAL OF ELECTRICAL SYSTEMS SHALL BE SEALED TO MAINTAIN THE FIRE

RATING OF THE WALL. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS

FOR REQUIREMENTS, MATERIALS, AND METHODS OF SEALING PENETRATIONS

THROUGH WALLS. THROUGH-PENETRATION FIRESTOP SHALL COMPLY WITH IBC.

18. PROVIDE TYPED, AND DATED DIRECTORY CARDS UNDER PLASTIC COVER FOR

BRANCH CIRCUIT PANELBOARDS. DIRECTORIES SHALL DESCRIBE CIRCUIT BEING

SERVED, ROOM NAMES, AND ROOM NUMBERS WHERE DEVICES OR FIXTURES ARE

LOCATED. ROOM NAMES AND NUMBERS SHALL MATCH THE GRAPHICS INSTALLED IN

THE FIELD IF DIFFERENT FROM THE ROOM NAMES AND NUMBERS ON THE

DRAWINGS.

19. PROVIDE EXPANSION COUPLINGS, UNIONS, AND FITTINGS AS NECESSARY ON EACH

CONDUIT; AT MINIMUM, PROVIDE EXPANSION COUPLINGS AT EACH ENTRY/EXIT OF

ENCASED CONDUIT AND AT EACH CONCRETE EXPANSION JOINT. COORDINATE WITH

STRUCTURAL DRAWINGS AND GENERAL CONTRACTOR FOR SUCH LOCATIONS.

20. CONDUITS PENETRATING THROUGH ROOF SHALL HAVE ROOF FLASHING WITH

CAULK TYPE COUNTER FLASHING SLEEVE. INSTALLATION SHALL BE WATERTIGHT.

21. IF IT IS NECESSARY TO INSTALL EXPOSED CONDUIT, PAINT EXPOSED CONDUIT TO

MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA.

22. BACK-TO-BACK MOUNTING OF DEVICES WITHIN A COMMON WALL STRUCTURE IS

NOT PERMITTED. THE MINIMUM SEPARATION IS 6-INCHES IN COMMON WALLS AND

24-INCHES IN SOUND RATED WALLS.

23. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING COMPLETE AND FUNCTIONAL

SYSTEMS BY COORDINATING WORK BETWEEN TRADES. COORDINATE WITH OTHER

TRADES FOR PROVISION OF STARTERS, DISCONNECTS, 120V CONTROL WIRING,

BOXES AND ANY REQUIRED RACEWAYS. FACTOR STARTERS, VFDS, DISCONNECTS,

AND COMBINATION STARTERS SHALL BE UTILIZED ON MECHANICAL EQUIPMENT

WHEN POSSIBLE. TECHNOLOGY CONTRACTOR MAY UTILIZE EQUIPMENT PROVIDED

BY ELECTRICAL CONTRACTOR AND VICE VERSA TO DELIVER A FULLY OPERATIONAL

SYSTEM. REFER TO THE MECHANICAL, PLUMBING, FIRE ALARM, AND TECHNOLOGY

DRAWINGS, DETAILS AND DIVISION 22, 23, 27 AND 28 SPECIFICATIONS FOR

LOCATIONS, SIZES, AND ANY ADDITIONAL INFRASTRUCTURE REQUIREMENTS.

24. MAKE ALL FINAL ELECTRICAL CONNECTIONS TO EQUIPMENT REQUIRING

ELECTRICAL CONNECTION. THIS SHALL INCLUDE BUT NOT BE LIMITED TO ALL

MECHANICAL AND OTHER EQUIPMENT INCLUDED IN THIS PROJECT BY OTHER

TRADES AND THE OWNER. FOR EQUIPMENT SUPPLIED BY OTHERS (INCLUDING

OFOI, OFCI, AND CFCI EQUIPMENT), COORDINATE CONNECTION, CONTROLS,

ROUGH-IN REQUIREMENTS, AND LOCATIONS WITH EQUIPMENT SUPPLIER, OWNER,

AND ARCHITECT PRIOR TO ROUGH-IN.

25. WIRE SHALL BE COPPER, 60 DEGREES C RATED FOR ALL CIRCUITS/FEEDERS 100

AMPS OR LESS, 75 DEGREES C RATED FOR ALL CIRCUITS/FEEDERS OVER 100 AMPS.

WIRING WITHIN 3 INCHES OF FLUORESCENT BALLASTS WIRE SHALL BE COPPER,

MINIMUM 90 DEGREES C RATED. SIZES INDICATED ARE FOR INSTALLATION IN A

MAXIMUM 30 DEGREES C AMBIENT. CONDUCTOR AMPACITY SHALL BE DE-RATED

FOR HIGHER AMBIENT INSTALLATIONS.

26. ALL CIRCUITS SHALL INCLUDE A SEPARATE GREEN INSULATED GROUNDING

CONDUCTOR SIZED IN ACCORDANCE WITH NEC ARTICLE 250, OR LARGER IF NOTED

(#12 AWG MINIMUM SIZE).

27. PROVIDE INDIVIDUAL NEUTRALS ON ALL NEW CIRCUITS.

28. SUPPORT ALL CONDUITS, CABLES, AND BOXES FROM STRUCTURE.

29. IDENTIFY JUNCTION BOXES WITH PANEL AND CIRCUIT NUMBER.

30. CONTRACTOR SHALL PROVIDE WORKING CLEARANCES ABOUT ELECTRICAL

EQUIPMENT PER NEC ARTICLE 110.

31. DEVICES AT MASONRY AND EXPOSED CONCRETE WALLS IN FINISHED AREAS NOT

SCHEDULED TO HAVE GYP FURRING ARE TO BE FLUSH MOUNTED. AT CONCRETE

WALLS AND CEILINGS, EMBED CONDUIT IN CONCRETE.

32. A HOUSEKEEPING PAD SHALL BE PROVIDED FOR GRADE OR FLOOR MOUNTED

EQUIPMENT UNLESS NOTED OTHERWISE. REFER TO SPECIFICATIONS FOR

ADDITIONAL REQUIREMENTS.

33. ALL EMPTY CONDUIT SHALL BE DEBURRED, CLEANED, CAPPED, TAGGED, AND

FURNISHED WITH PULL-WIRES AND INSULATION BUSHINGS ON CONDUIT ENDS.

34. PER THE REQUIREMENTS OF THE IECC, THE CONTRACTOR SHALL TURN OVER

AS-BUILT DOCUMENTS TO THE BUILDING OWNER OR OWNER'S AUTHORIZED AGENT

WITHIN 90 DAYS OF THE DATE OF RECEIPT OF THE CERTIFICATE OF OCCUPANCY.

ELECTRICAL GENERAL NOTES

1. REFER TO THE MECHANICAL EQUIPMENT CONNECTION SCHEDULE ON THE

ELECTRICAL SCHEDULES SHEET FOR MECHANICAL EQUIPMENT FEEDER

INFORMATION AND BREAKER SIZES.

2. PROVIDE FUSES SIZED FOR EQUIPMENT INDICATED TO HAVE A FUSED DISCONNECT

PER EQUIPMENT MANUFACTURER REQUIREMENTS.

3. DISCONNECT SWITCH LOCATIONS ARE SHOWN DIAGRAMMATICALLY AND SHALL BE

INSTALLED IN AN ACCESSIBLE LOCATION TO SUIT EQUIPMENT AND SPACE.

DISCONNECT SWITCHES SHALL BE WITHIN SIGHT OF THE EQUIPMENT THEY SERVE

AND MOUNTED AT A MAXIMUM 6'-3" TO THE TOP OF THE OPERATING HANDLE.

MAINTAIN NEC WORKSPACE CLEARANCES AND REQUIREMENTS.

4. RECEPTACLES INDICATED TO BE MOUNTED ABOVE COUNTER ARE TO BE MOUNTED

HORIZONTALLY 6" ABOVE COUNTER.

5. COORDINATE AND VERIFY EXACT MOUNTING LOCATIONS AND HEIGHTS OF WALL

AND FLOOR DEVICES WITH ARCHITECTURAL PLANS, ELEVATIONS, AND MILLWORK

SHOP DRAWINGS OR ANY FURNITURE OR SPECIALTY EQUIPMENT SUPPLIER

DRAWINGS PRIOR TO ROUGH-IN. HEIGHTS INDICATED ARE TO THE CENTERLINE OF

THE DEVICE UNLESS OTHERWISE INDICATED.

6. COORDINATE EXACT REQUIREMENTS AND LOCATIONS OF MECHANICAL, PLUMBING,

FIRE/LIFE SAFETY, AND TECHNOLOGY EQUIPMENT WITH MECHANICAL, PLUMBING,

FIRE/LIFE SAFETY, AND TECHNOLOGY DRAWINGS, SPECIFICATIONS, DETAILS AND

CONTRACTORS PRIOR TO ROUGH-IN.

7. ALL GENERAL-PURPOSE RECEPTACLES IN SHOP AND/OR UTILITY AREAS SHALL BE

GFCI RATED AND MOUNTED AT +42" AFF.

8. NO RECEPTACLES SHALL BE MOUNTED BELOW +18" AFF UNLESS NOTED

OTHERWISE.

9. FOR RECEPTACLES DENOTED "TV", COORDINATE RECEPTACLE LOCATION AND

MOUNTING HEIGHT WITH TV BRACKET AND CATV OUTLET PRIOR TO ROUGH-IN.

10. THE CONTRACTOR SHALL TAKE DIMENSIONS FOR FLOOR MOUNTED DEVICES FROM

ARCHITECTURAL AND VENDOR DRAWINGS.

11. ALL 125V THROUGH 250V RECEPTACLES INSTALLED FOR VENDING MACHINES OR IN

LOCKER ROOMS, BATHROOMS, KITCHENS, ROOFTOPS, SHOPS, AND OUTDOORS,

AND WITHIN 6' OF THE OUTSIDE EDGE OF SINKS OR A WATER SOURCE SHALL BE

GFCI TYPE IN AN ACCESSIBLE LOCATION PER NEC OR PROTECTED BY A GFCI

BREAKER. WHERE RECEPTACLE IS NOT READILY ACCESSIBLE, PROVIDE A REMOTE

GFCI RESET BUTTON IN AN ACCESSIBLE LOCATION AND A NON-GFCI RECEPTACLE

IN THE INACCESSIBLE LOCATION. DO NOT DAISY CHAIN OR FEED-THROUGH GFCI

DEVICES.

12. RECEPTACLES FOR ELECTRIC WATER COOLERS TO BE CONCEALED BEHIND

SHROUD. REMOTE GFCI RESET BUTTON SHALL BE INSTALLED CENTERED 6" BELOW

THE BOTTOM OF THE ELECTRIC WATER COOLER. PROVIDE A SEPARATE

RECEPTACLE FOR EACH DRINKING FOUNTAIN COMPARTMENT. SEPARATE

RECEPTACLES CAN SHARE CIRCUIT INDICATED.

13. [DELETE MOTORS AND TRANSFORMERS IF YOU DON'T HAVE ANY] FINAL

CONNECTIONS TO MOTORS, TRANSFORMERS, AND OTHER VIBRATING EQUIPMENT

SHALL BE WITH SEAL TIGHT FLEX AND APPROVED FITTINGS. DO NOT SECURE

CONDUITS, DISCONNECTS, OR DEVICES TO DUCTWORK OR MECHANICAL

EQUIPMENT.

14. RECEPTACLES MOUNTED BACK-TO-BACK IN FIRE RATED WALLS SHALL BE

PROVIDED WITH A THROUGH-PENETRATION FIRESTOP SYSTEM.

15. ALL EXTERIOR RECEPTACLES TO HAVE METALLIC WEATHERPROOF WHILE IN-USE

COVERS.

16. PROVIDE AND INSTALL A RECEPTACLE WITHIN 25' OF HVAC EQUIPMENT.

17. MOUNT ROOF-MOUNTED RECEPTACLE ENCLOSURE ON STAINLESS STEEL

UNISTRUT CHANNEL SUPPORT/STAND 18-INCHES ABOVE FINISHED ROOF TO

BOTTOM OF RECEPTACLE. PROVIDE FLASHING AT CONDUIT ROOF PENETRATION.

CONDUIT SHALL BE GALVANIZED RIGID STEEL AT PENETRATION EXTENDING TO

RECEPTACLE BOX CONNECTION. RECEPTACLE MAY BE MOUNTED TO ROOFTOP

EQUIPMENT OR ROOFTOP EQUIPMENT SUPPORTS IN LIEU OF SUPPORT/STAND IF

NEC AND IMC REQUIREMENTS ARE MAINTAINED AND SUCH MOUNTING IS

ACCEPTABLE TO ROOFTOP EQUIPMENT MANUFACTURER/SUPPLIER.

18. CONNECTIONS TO ITEMS INDICATED BY WORK NOTES OR OTHER NOTATION SHALL

BE 20A, 120V, 1[(2#12 + 1#12G) 3/4"C] UNLESS NOTED OTHERWISE.

19. FEEDS TO FURNITURE SYSTEM PANELS SHALL BE CONFIGURED TO MATCH

FURNITURE SYSTEM CIRCUITRY REQUIREMENTS, WITH THE SAME NUMBER OF

PHASE, NEUTRAL, AND GROUND CONDUCTORS. MULTIPLE CIRCUITS SHARING A

COMMON NEUTRAL CONDUCTOR IN THE SAME BRANCH CIRCUIT FEED SHALL HAVE

COMMON HANDLE TIE ON BREAKERS.

20. PROVIDE TAMPER RESISTENT RECEPTACLES IN ALL SPACES REQUIRED BY THE

NEC.

21. PROVIDE WALL AND FLOOR MOUNTED DEVICES IN MEETING ROOMS AS REQUIRED

IN NEC 210.65. PROVIDE UNIT PRICE FOR ADDITIONAL FLOOR BOXES AND

WALL-MOUNTED RECEPTACLES INCLUDING INSTALLATION AS REQUIRED BY

INSPECTOR (AHJ).

POWER PLAN GENERAL NOTES

1. DEMOLITION DRAWINGS MAY NOT SHOW EVERY ITEM TO BE DEMOLISHED. DURING

PRE-BID SITE VISIT, CONTRACTOR SHALL DETERMINE THE EXACT EXTENT OF

DEMOLITION TO FACILITATE ALL WORK INDICATED BY THE CONTRACT DOCUMENTS

PRIOR TO QUOTATION. NO EXTRAS WILL BE ALLOWED FOR WORK REQUIRED TO

ACHIEVE THE END RESULT AS INDICATED BY THE CONTRACT DOCUMENTS.

REMOVE OR REWORK EXISTING ELECTRICAL SYSTEMS AS REQUIRED WHEN IN

CONFLICT WITH NEW CONSTRUCTION. REWORK EXISTING TERMINATIONS,

CONNECTIONS, CONDUIT, WIRING, ETC. TO ACCEPT NEW WORK. MAINTAIN CIRCUIT

CONTINUITY TO EXISTING CIRCUITS AND DEVICES TO REMAIN OR BE RELOCATED.

WIRING AND RACEWAY SHALL BE PROVIDED AS NECESSARY TO REENERGIZE

EXISTING DEVICES TO REMAIN WHEN POWER TO SUCH DEVICES IS INTERRUPTED

DUE TO DEMOLITION OF OTHER DEVICES ON THE SAME CIRCUIT. PRIOR TO

COMMENCEMENT OF ANY DEMO WORK, CONFIRM EXISTING CONDITIONS AND

NOTIFY ENGINEER OF ANY DISCREPANCIES REQUIRING RESOLUTION.

2. COORDINATE WITH ARCHITECTURAL DRAWINGS FOR WALL, FLOOR, AND CEILING

DEMOLITION REQUIREMENTS.

3. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SCHEDULE ALL DEMOLITION

WORK WITH THE OWNER WELL IN ADVANCE. WORK SHALL BE PERFORMED AT

SUCH TIMES AND UNDER SUCH CONDITIONS AS SUITS THE OWNER. DEMOLITION

SHALL BE STAGED TO MINIMIZE THE AMOUNT OF DOWNTIME.

4. PRIOR TO DEMOLITION WORK, THE CONTRACTOR SHALL CIRCUIT TRACE ALL

DEVICES AND BRANCH CIRCUITS WITHIN THE AREA OF RENOVATION. ALL EXISTING

PANELBOARD DIRECTORY CARDS SHALL BE UPDATED TO REFLECT FINDINGS.

5. WHERE COMPLETE CIRCUITS ARE DEMOLISHED, THE WIRING SHALL BE

DEMOLISHED BACK TO THE BRANCH CIRCUIT PANELBOARD. UNDER NO

CIRCUMSTANCES ARE ABANDONED DEVICES OR BRANCH CIRCUITS ALLOWED. DO

NOT LEAVE WIRES CONNECTED TO SPARE CIRCUIT BREAKERS. RACEWAYS MAY

REMAIN, AND BE REUSED WHERE APPLICABLE. RACEWAYS AND BRANCH CIRCUITS

NOT REUSED FOR NEW CONSTRUCTION SHALL BE COMPLETELY DEMOLISHED,

INCLUDING PIPE HANGERS, STRAPS, OR TIE WIRES ANCHORED IN CONCRETE SLAB

ABOVE CEILING THAT ARE NO LONGER IN USE. PATCH HOLES LEFT IN WALLS AND

FLOORS AFTER REMOVAL OF EXISTING PIPING, CONDUIT, ETC. TO MATCH NEW OR

EXISTING CONSTRUCTION AND FIRE RATING.

6. ALL ITEMS IDENTIFIED TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY

INCLUDING ALL WIRING AND EXPOSED CONDUIT AND CONDUIT SUPPORTS BACK TO

POINT OF ORIGIN OR NEXT DEVICE TO REMAIN. CONTRACTOR SHALL USE CARE IN

REMOVING DEVICES AND FIXTURES AND THEN SHALL MAKE THEM AVAILABLE TO

THE OWNER FOR FUTURE USE. OWNER ACCEPTED ITEMS, UNLESS OTHERWISE

NOTED, SHALL BE STORED IN AN AREA DESIGNATED BY THE OWNER. ALL DEVICES

AND FIXTURES NOT RETAINED BY THE OWNER SHALL BE DISPOSED OF LEGALLY BY

THE CONTRACTOR. IF ANY HAZARDOUS MATERIALS ARE DISCOVERED DURING

DEMOLITION, NOTIFY OWNER AND ARCHITECT FOR FURTHER DIRECTION.

7. WALL BOXES IN EXISTING WALLS TO REMAIN SHALL BE LEFT IN PLACE. REUSE

THESE BOXES FOR NEW WIRING DEVICES IF THE EXISTING BOX IS WITHIN

12-INCHES LATERALLY OF NEW DEVICE LOCATION AND AT THE SAME MOUNTING

HEIGHT AND WHERE CURRENT NEC AND LOCAL CODE REQUIREMENTS ARE

MAINTAINED. EXISTING BOXES CAN ONLY BE RE-UTILIZED IN PLACE AND CANNOT

BE RELOCATED. PROVIDE BLANK COVERPLATES FOR EXISTING BOXES NOT

REUSED FOR NEW DEVICES.

8. WHERE EXISTING CONDUITS ARE BEING REMOVED AND HAVE BEEN ROUTED IN

CONCRETE FLOOR SLABS, CONCRETE WALLS, OR CONCRETE CEILINGS, THEY

SHALL BE CUT BACK FLUSH WITH CONCRETE. FILL WITH GROUT TO ACHIEVE A

SMOOTH AND EVEN FINISH FLUSH WITH CONCRETE SURFACE AFTER CONDUCTORS

HAVE BEEN REMOVED.

9. REFER TO OTHER TRADES' DRAWINGS FOR ITEMS DEMOLISHED BY OTHERS.

ELECTRICAL CONTRACTOR SHALL DEMOLISH ALL RELATED ELECTRICAL WIRING,

CONDUIT AND ASSOCIATED ELECTRICAL EQUIPMENT, ETC. AS REQUIRED AS PART

OF THIS PROJECT.

ELECTRICAL DEMOLITION GENERAL NOTES

1. REFER TO ELECTRICAL SCHEDULES SHEET FOR LIGHTING CONTROL SCHEDULE

AND LIGHTING CONTROL SCHEDULE AND NOTES.

2. COORDINATE AND VERIFY EXACT MOUNTING LOCATIONS AND HEIGHTS OF WALL

DEVICES WITH ARCHITECTURAL PLANS, ELEVATIONS, AND MILLWORK SHOP

DRAWINGS PRIOR TO ROUGH-IN. HEIGHTS INDICATED ARE TO THE CENTERLINE OF

THE DEVICE UNLESS OTHERWISE INDICATED.

3. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR CEILING TYPES AND

EXACT LOCATION OF ALL FIXTURES. COORDINATE AND VERIFY ALL LUMINAIRE

REQUIREMENTS WITH ARCHITECT PRIOR TO PREPARING SUBMITTALS INCLUDING,

BUT NOT LIMITED TO, MOUNTING METHOD, MOUNTING HEIGHT(S), CEILING TYPES,

AND FINISHES AND/OR COLORS. COORDINATE LUMINAIRE LOCATIONS WITH

MECHANICAL PIPING, DUCTWORK, FIRE PROTECTION, CABLE TRAY, CONDUIT, ETC.

TO AVOID CONFLICTS.

4. RECESSED FIXTURES INSTALLED INDOORS SHALL BE THERMALLY PROTECTED.

5. SUPPORT ALL LUMINAIRES FROM STRUCTURE. LAY-IN FIXTURES SHALL BE

SUPPORTED WITH TWO #12AWG WIRES FROM OPPOSITE ENDS UNLESS OTHERWISE

NOTED.

6. PROVIDE NEUTRAL AND GROUND CONDUCTORS THROUGHOUT ALL LIGHTING

BRANCH CIRCUITS INCLUDING ALL SWITCH OR LIGHTING CONTROL DEVICE

LOCATIONS.

7. ALL LIGHTING CONTROLS SHALL COMPLY WITH IECC. REFER TO APPLICABLE

CODES LISTED ON ARCHITECTURAL CODE PLAN AND ELECTRICAL GENERAL

INFORMATION SHEET FOR SPECIFIC VERSION OF IECC APPLICABLE TO PROJECT.

8. LOCATIONS OF OCCUPANCY SENSORS ARE DIAGRAMMATIC. FIELD COORDINATE

EXACT LOCATIONS OF CEILING MOUNTED OCCUPANCY SENSORS PER

MANUFACTURER'S INSTRUCTIONS. MANUFACTURER DRAWINGS SHALL BE

PROVIDED INDICATING COVERAGE AREAS. IF ADDITIONAL SENSORS ARE NEEDED

FOR COMPLETE COVERAGE OF SPACE, THEY SHALL BE PROVIDED AND INSTALLED

BY THE CONTRACTOR AS REQUIRED TO PROVIDE COMPLETE SPACE COVERAGE.

DO NOT LOCATE OCCUPANCY SENSORS WITHIN SIX FEET OF AN HVAC SUPPLY

DEVICE. CARE SHALL BE TAKEN TO LOCATE SENSORS AWAY FROM WINDOWS TO

MINIMIZE NUISANCE TRIPPING.

9. CONTRACTOR SHALL PROVIDE ALL NECESSARY SWITCH PACKS FOR OCCUPANCY

SENSORS TO PROVIDE FUNCTION INDICATED.

10. ALL OCCUPANCY SENSORS SHALL HAVE AN AUXILIARY CONTACT THAT WILL ALLOW

THEM TO INTERFACE WITH THE HVAC SYSTEM.

11. ALL EMERGENCY LIGHTING SHALL BE NORMALLY CONTROLLED. LOSS OF UTILITY

POWER SHALL ENERGIZE ALL EGRESS LIGHTING TO FULL BRIGHT. THE DESIGN

SHALL MEET ALL UL STANDARDS FOR EMERGENCY REQUIREMENTS.

12. LOW VOLTAGE LIGHTING CONTROL WIRING IN EXPOSED SPACES SHALL BE RUN

CONCEALED IN WALLS WHERE POSSIBLE. EXPOSED RUNS ACROSS CEILING SHALL

BE RUN IN CONDUIT, PAINTED TO MATCH ADJACENT FINISH.

LIGHTING GENERAL NOTES

1. DISTRIBUTION EQUIPMENT SHALL BE FULLY RATED (NOT SERIES RATED).

2. PROVIDE A FRAMED RECORD DRAWING OF ONE-LINE MOUNTED ON MAIN

ELECTRICAL ROOM WALL FOR REFERENCE.

3. SOME PANELBOARDS HAVE MULTIPLE SECTIONS. REFER TO FLOOR PLANS AND

PANEL SCHEDULES FOR NUMBER OF SECTIONS PER PANELBOARD AND

ADDITIONAL INFORMATION ON BRANCH CIRCUITING. IF USING AN 84-POLE SINGLE

SECTION PANEL, WIREWAY SHALL NOT BE LOCATED MORE THAN 2' ABOVE PANEL

UNLESS WIRING IS DERATED.

4. REFER TO THE MECHANICAL EQUIPMENT CONNECTION SCHEDULE ON ELECTRICAL

SCHEDULES SHEET FOR MECHANICAL EQUIPMENT FEEDER INFORMATION AND

BREAKER SIZES.

5. REFER TO THE DRY TYPE TRANSFORMER SCHEDULE ON THE ELECTRICAL ONE-LINE

DIAGRAM SHEET FOR TRANSFORMER FEEDERS AND GROUNDING REQUIREMENTS.

NOT ALL TRANSFORMER SIZES INDICATED ARE UTILIZED AS PART OF THIS

PROJECT.

6. REFER TO THE FEEDER TABLE ON THE ELECTRICAL ONE-LINE DIAGRAM SHEET FOR

FEEDER SIZING REQUIRMENTS. NOT ALL FEEDERS INDICATED ARE UTILIZED AS

PART OF THIS PROJECT.

7. CONNECTION OF CONDUCTORS TO EQUIPMENT TERMINALS SHALL BE IN

ACCORDANCE WITH NEC SECTION 110.14.

8. SHORT CIRCUIT CURRENT CALCULATIONS AND AIC RATINGS ON DRAWINGS SHALL

BE CONSIDERED PRELIMINARY (BASED ON ENGINEER ASSUMPTION OF UTILITY

TRANSFORMER SIZE AND FEEDER LENGTHS) FOR CONTRACTOR PRICING

PURPOSES. CONTRACTOR SHALL PERFORM SHORT CIRCUIT CURRENT

CALCULATIONS AND ARC-FLASH STUDY FOR BUILDING ELECTRICAL DISTRIBUTION

BASED ON INTENDED INSTALLATIONS AND ISSUE SUCH STUDY WITH DISTRIBUTION

EQUIPMENT SUBMITTALS. UTILIZE TRANSFORMER SIZE AND AVAILABLE FAULT

LEVEL AS DICTATED BY UTILITY COMPANY FOR SUCH CALCULATIONS. BASED ON

STUDY, CONTRACTOR SHALL:

A. ADJUST AIC RATINGS OF EQUIPMENT IN SUBMITTALS BASED ON SHORT CIRCUIT

CURRENT STUDY.

B. PROVIDE ARC-FLASH HAZARD WARNING LABELING ON EQUIPMENT PER NEC

REQUIREMENTS BASED ON SUCH STUDY RESULTS.

C. COORDINATE WITH MECHANICAL CONTRACTOR TO ENSURE THAT MECHANICAL

EQUIPMENT AIC RATINGS ARE ABOVE SUCH CALCULATED SHORT CIRCUIT CURRENT

LEVELS. ELECTRICAL CONTRACTOR SHALL PROVIDE LOCAL FUSED DISCONNECT

SWITCHES TO ASSIST MECHANICAL CONTRACTOR WITH RESOLUTION OF CONDITIONS

WHERE LARGER AIC RATINGS OF MECHANICAL EQUIPMENT IS NOT AVAILABLE BUT LET

THROUGH OF FUSES AND AIC RATING OF FUSED DISCONNECT CAN ADDRESS THE ISSUE.

ELECTRICAL ONE-LINE GENERAL NOTES

M 1

Sheet Title:

Sheet no:

Drawn by:

Checked by:

Scale:

Date:

No: Date:Description:

7/10/2026

AS NOTED

BCER PROJECT

6555 N. WICKHAM ROAD, SUITE 104

MELBOURNE, FL 32940 | 321.241.4124

CA# 9303

XXXXXXXX

© Copyright BCER Engineering

ALL DRAWINGS, SPECIFICATIONS, AND OTHER WORK PRODUCT PREPARED BY BCER

ENGINEERING FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE

PROPERTY OF BCER ENGINEERING. BCER ENGINEERING SHALL RETAIN ALL COMMON LAW,

STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO.

D

IX

IE

H

O

LL

IN

S

H S

LI

FT

ST

AT

IO

N

R

EP

LA

C

EM

EN

T

2n d

St N

St . P et er sb ur g, F

L

JRB

MC

ELECTRICAL SITE

DEMOLITION PLAN

ED1.01

GENERAL NOTES

**REFER TO ELECTRICAL PROJECT NOTES SHEET FOR ADDITIONAL REQUIREMENTS**

DISCONNECT EXISTING LIFT STATION POWER FEEDER. REMOVE FEEDER BACK TO

LIFT STATION DISCONNECT SWITCH IN ELECTRICAL ROOM. MAINTAIN CONDUIT TO

BE REUSED.

WORK NOTES

N

ELECTRICAL SITE DEMOLITION PLAN

1" = 10'-0"

05' 5' 10' 20'

M 1

Issue Record:

Sheet Title:

Sheet no:

Drawn by:

Checked by:

Scale:

Date:

No: Date:Description:

7/10/2026

AS NOTED

BCER PROJECT

6555 N. WICKHAM ROAD, SUITE 104

MELBOURNE, FL 32940 | 321.241.4124

CA# 9303

XXXXXXXX

© Copyright BCER Engineering

ALL DRAWINGS, SPECIFICATIONS, AND OTHER WORK PRODUCT PREPARED BY BCER

ENGINEERING FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE

PROPERTY OF BCER ENGINEERING. BCER ENGINEERING SHALL RETAIN ALL COMMON LAW,

STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO.

D

IX

IE

H

O

LL

IN

S

H S

LI

FT

ST

AT

IO

N

R

EP

LA

C

EM

EN

T

2n d

St N

St . P et er sb ur g, F

L

JRB

MC

ELECTRICAL SITE

PLAN

E1.01

NEW LOCATION OF LIFTSTATION PUMP AND CONTROLLER. PROVIDE NEW FEEDER

WITH (3) #6AWG + (1) #10G FROM DISCONNECT IN ELECTRICAL ROOM TO NEW

LOCATION OF LIFT STATION AND CONNECT TO NEW CONTROLLER. REUSE

EXISTING CONDUIT AND EXTEND TO NEW LOCATION AS REQUIRED. PROVIDE

CONDUIT AND WIRING BETWEEN CONTROLLER, PUMPS, AND SENSORS PER

MANUFACTURER INSTALLATION INSTRUCTION. THE LIFT STATION IS A

ONE-FOR-ONE REPLACEMENT. NO ADDED LOAD.

REPLACE EXISTING FUSES WITH 50A FUSES IN EXISTING FUSED DISCONNECT.

PROVIDE FUSE REDUCERS SUCH THAT 50A FUSE WILL FIT IN 200A DISCONNECT.

CONTRACTOR SHALL CONFIRM TYPE OF FUSES BEFORE PROCURING.

WORK NOTES

N

ELECTRICAL SITE PLAN

1" = 10'-0"

05' 5' 10' 20'

EQUIPMENT SCHEDULE

PLAN CODE

LS-1

GENERAL NOTES

A.

NOTES

1.

2.

3.

DESCRIPTION

LIFT STATION

COORDINATE AND VERIFY ALL EQUIPMENT REQUIREMENTS WITH SUPPLIER AND MECHANICAL DRAWINGS PRIOR TO SUBMITTALS INCLUDING, BUT NOT LIMITED TO, VOLTAGE, OVERCURRENT PROTECTION, CONTROL, DICONNECTING MEANS, ETC.

SINGLE POINT ELECTRICAL CONNECTION. DISCONNECT INTERGRAL TO CONTROLLER.

MANUFACTURER PROVIDED FUSED DISCONNECT SWITCH SHALL BE INTEGRAL TO CONTROLLER AND CONNNECTED BY DIVISION 26.

PROVIDE SPD ON EXISTING CIRCUIT IF ONE IS NOT INSTALLED. (PQ PROTECTION PQM200)

VOLTAGE

PH

HP

FLA

30.8

MCA

38.5

MOCP

EX

KVA

11.1

SIZE

FUSE SIZE

NEMA RATING

4X

PANEL

EX

CIRCUIT

EX

CB SIZE

EX

FEEDER SIZE

(3) #6AWG + (1) #10G IN EX C

NOTES

1, 2, 3

GENERAL NOTES

**REFER TO ELECTRICAL PROJECT NOTES SHEET FOR ADDITIONAL REQUIREMENTS**