25042C2.0DemolitionUtilityPlanAddendumNo01.pdf

PDF 3 MB Posted

Attached to
Lift Station Replacement
Solicitation number
26-CD-033
Issued by
Pinellas County, Florida

About this file

This is a Demolition and Utility Plan Addendum (Sheet C2.0) prepared by BCER Engineering for the Hollins High School Lift Station Replacement project located at 6440 62nd Street North, St. Petersburg, Florida 33709, under the Pinellas County School District's ITB #26-CD-033. The project scope includes complete demolition of the existing lift station and associated infrastructure, removal of approximately 1,006 square feet of brick pavers (with commemorative bricks to be reinstalled), removal of existing palm trees, abandonment of utility lines, and removal of various fencing sections and gates. The contractor must maintain the existing lift station and 4-inch force main in service during construction, pump down and remove existing raw sewage after decommissioning, disinfect and collapse the existing well per Department of Health standards, and ensure no part of the existing concrete wet well remains within four feet of final grade. New construction includes installation of a 28-linear-foot 4-inch C-900 PVC force main, 14-linear-foot 10-inch SDR35 PVC sanitary sewer at 3.17% slope, 4-inch Class 50 ductile iron restrained water main, 6-inch Class 50 ductile iron restrained fire main, 800 square feet of red brick pavers, temporary and permanent chain-link fencing with vinyl slats, a proposed concrete pad, and site restoration with crushed shell and ribbon curbing. The mandatory pre-bid conference is scheduled for August 12, 2026 at 9:00 a.m. at the school site, with bids due by 4:00 p.m. on August 31, 2026, and the contract period is 60 calendar days from Notice to Proceed with liquidated damages of $150 per calendar day.

The estimated contract value is approximately $485,000 including a 10 percent contingency. Prime contractors must hold a current Florida License as a Utility Contractor, demonstrate five years of continuous business operation as the same legal entity, and provide documented experience performing five comparable utilities and lift station replacement projects within the past five years. All subcontractors must be licensed within their respective trades and pre-approved by the District. All materials and equipment must be listed or labeled by UL or equivalent recognized testing facility and comply with 2023 Florida Building Code, 2023 Florida Existing Building Code, NFPA 70-2020 National Electrical Code, ASTM D-3034 for PVC gravity sewer, AWWA C-900 and C-905 for water and fire mains, and AWWA C600 and C605 for pressure testing standards. General Liability Insurance minimum limits are $1,000,000 per occurrence and $2,000,000 general aggregate. The contractor must provide bid and performance security, proof of E-Verify registration, background screening clearance under the Jessica Lunsford Act, and executed affidavits regarding labor coercion and public entity crimes. Bid evaluation and contractor selection are scheduled for September 2-8, 2026, with Notice of Intent to Award by October 6, 2026 and School Board approval anticipated by October 13, 2026. The District will consider pricing from Florida Department of Management Services contracts in evaluation.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CONCRETE

TO BE REMOVED

EXISTING 8-FT GATE TO REMAIN CLOSED DURING CONSTRUCTION

SAW CUT

REMOVE ABANDONED MANHOLE

BEGIN TEMPORARY

CONSTRUCTION FENCE

REMOVE AND STOCKPILE THE

BRICK PAVERS ( ± 1,006 SQFT)

EXERCISE CARE WHEN REMOVING

COMMEMORATIVE BRICKS

REMOVE

EXISTING

PALM TREE

END TEMPORARY

CONSTRUCTION

FENCE

X

REMOVE ABANDONED UTILITY LINES

REMOVE 18 LF OF FENCE AND 2 X GATES

STAGING

AREA

X X

REMOVE EXISTING

2 X PALM TREES

X

REMOVE 17 LF

OF 4-FT FENCE

REMOVE 31 LF OF 4-FT FENCE

DEMOLITION PROCEDURE

1. EXISTING LIFT STATION AND 4" FM TO REMAIN IN

SERVICE DURING CONSTRUCTION OF THE

PROPOSED REPLACEMENT LIFT STATION.

2. PUMP DOWN AND REMOVE EXISTING RAW

SEWAGE AFTER STATION IS DECOMMISSIONED.

3. REMOVE EXISTING WELL BUILDING, PUMPS,

INTERNAL PIPES, ELECTRICAL COMPONENTS,

AND FORCE MAIN TO TIE-IN LOCATION

4. DISINFECT AND COLLAPSE/REMOVE THE

EXISTING WELL PER DEPARTMENT OF HEALTH

STANDARDS. NO PART OF THE EXISTING

CONCRETE WET WELL/SLAB SHALL REMAIN

WHITIN FOUR(4) FEET OF FINAL GRADE.

SAW CUT EXISTING CONCRETE

3.3'

2.7'

X

REMOVE GATE VALVE AND 8 LF OF WATER LINE

(UNKNOWN MATERIAL AND DIAMETER)

REMOVE 40 LF OF 4" WATER AND 6" FIRE MAINS

INSTALL TEMPORARY

CONSTRUCTION FENCE

REMOVE 3"

FORCE MAIN

CONNECT PROPOSED PVC FORCE MAIN TO

EXISTING 4" FORCE MAIN WITH 45° BEND

45° BEND

28 LF 4" C-900 PVC FORCE MAIN

DOGHOUSE MANHOLE

RIM: 20.60

INV IN N: 14.14 (EXIST.)

INV IN SE: 14.14

INV OUT SW: 14.04 (-0.1 N)

GROUT EXISTING SOUTH INVERT

WHEN TIE-INS ARE COMPLETE

8-FT LIFT STATION

RIM: 20.70

INV NE: 13.60

14 LF 10" SDR35 PVC SANITARY SEWER AT 3.17%

45° BEND

RPZ SEE DETAIL SHEET C3.0

CONNECT PROPOSED PVC FORCE MAIN TO

EXISTING 3" FORCE MAIN WITH 45° BEND

INSTALL WATER AND FIRE MAINS OVER FORCE MAIN

SEE WATER AND SEWER CLEARANCE REQUIREMENTS SHEET C1.0

CONNECT TO EXISTING

WATER LINE WITH 45° BEND

4" CLASS 50 DUCTILE IRON (RESTRAINED) WATER MAIN

6" CLASS 50 DUCTILE IRON (RESTRAINED) FIRE MAIN

45 ° BENDS

CONNECT TO EXISTING

WATER LINE WITH 45° BEND

CONNECT TO EXISTING FIRE

LINE WITH 45° BEND

CONNECT TO EXISTING

FIRE LINE WITH 45° BEND

FIELD VERIFY EXISTING LATERAL CONNECTION MATERIAL AND DIAMETER

4" X ?" TEE, ?" GATE VALVE, X" REDUCER

CONNECT TO EXISTING WATER LINE WITH 45° BEND

45° BEND

SERVICE TAP

GROUT TERMINAL END OF

ABANDONED FORCE MAIN

GROUT TERMINAL END OF

ABANDONED FORCE MAIN

45 ° BENDS

28 LF 3" SCHEUDLE 40 PVC FORCE MAIN

CONNECT TO EXISTING FENCE

CONNECT TO EXISTING FENCE

2x6-FT SWING GATE WITH VINYL SLATS

PER PINELLAS COUNTY SCHOOLS PAE HANDBOOK AND DESIGN CRITERIA

4'-FT TALL BLACK-VINYL-COATED CHAIN LINK FENCE WITH GALVANIZED POSTS

PER PINELLAS COUNTY SCHOOLS PAE HANDBOOK AND DESIGN CRITERIA

CENTERED ON 12"-WIDE RIBBON CURB FLUSH WITH PROPOSED BRICK PAVERS

PER RIBBON CURB DETAIL SHEET C3.0

14.0'

± 800 SQFT RED BRICK PAVERS

REINSTALL COMMEMORATIVE BRICKS PER OWNER

AND BRICK PAVER DETAIL SHEET C3.0

7.5'

PROPOSED CONCRETE PAD

SEE DETAIL SHEET C3.0

12"X12" RIBBON CURB INSIDE EXISTING FENCE

FLUSH WITH EXISTING GRADE AND PROPOSED PAVERS / CRUSHED SHELL

4" CRUSHED SHELL WITH FG27 GEOTEXTILE OR EQUIVALENT

CONNECT TO EXISTING FENCE

BEGIN ADD VINYL SLATS TO EXISTING FENCE

CONNECT TO EXISTING FENCE

LIFT STATION CONCRETE SLAB

SEE DETAIL SHEET C4.0

ADJUST ELECTRICAL PULL BOX TO GRADE

6'-FT TALL GALVANIZED CHAIN LINK FENCE WITH VINYL SLATS PER

PINELLAS COUNTY SCHOOLS PAE HANDBOOK AND DESIGN CRITERIA

CENTERED ON 12"-WIDE RIBBON CURB

PER RIBBON CURB DETAIL SHEET C3.0

CONNECT TO EXISTING FENCE

END ADD VINYL SLATS TO EXISTING FENCE

9.1

12.6'

8.4

RIBBON CURB FLUSH

WITH CONCRETE PAD

NOTE:

VINYL SLATS TO BE BLUE AS OWNER SPECIFIED

CONTROL JOINT (TYP)

EXPANSION JOINT (TYP)

ME 20.87±

ME 20.69±

ME 20.71±

ME 20.44±

ME 19.77±

ME 20.38±

ME 20.71±

20.00

20.30 20.20

20.25

20.55

20.70 20.65

20.60

20.6020.40

20.70

20.55

ME 20.95±

6'-FT TALL GALVANIZED CHAIN LINK FENCE WITH VINYL SLATS PER

PINELLAS COUNTY SCHOOLS PAE HANDBOOK AND DESIGN CRITERIA

20.70

20.70

20.70

DEMOLITION PLAN

ELEVATIONS ARE BASED ON NORTH

AMERICAN VERTICAL DATUM OF 1988

(NAVD88)

C2.0

DEMOLITION,

UTILITY, AND

SITE AND GRADING PLAN

X

LEGEND UTILITY PLAN

UTILITY NOTES

Issue Record:

Sheet Title:

Sheet no:

Drawn by:

Checked by:

Scale:

Date:

No: Date:Description:

JULY 10, 2026

AS NOTED

BCER PROJECT

6555 N. WICKHAM ROAD, SUITE 104

MELBOURNE, FL 32940 | 321.241.4124

CA# 9303

© Copyright BCER Engineering

ALL DRAWINGS, SPECIFICATIONS, AND OTHER WORK PRODUCT PREPARED BY BCER

ENGINEERING FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE

PROPERTY OF BCER ENGINEERING. BCER ENGINEERING SHALL RETAIN ALL COMMON LAW,

STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO.

H O

LL

IN

S H

S

LI

FT

ST

AT

IO

N R

EP

LA

C

EM

EN

T

2n d St

N St

. P et er sb ur g, F L

PLANNING ENGINEERING CONSTRUCTION ADMINISTRATION

7026 LITTLE ROAD NEW PORT RICHEY, FLORIDA 34654

727-849-8010 Fax 727-849-8020

CA# 00009572

Pl ot-

T:

CD

C\

Pr oje cts \25

2 H oll ins

H S

Lif t S tat ion

\D ra wi ng s\C on str uc tio n\2

_C 2.0

D em oli tio n- Ut ilit yP lan .dw g - A ug

, 2

6 @ 4:

pm

JT

rip p

JLT

PAM

LEGEND

10" GRAVITY SEWER MINIMUM SLOPES @ 0.28%

SITE AND GRADING PLAN

DEMOLITION NOTES

REUSE EXISTING FENCE MATERIALS WHERE SALVAGABLE

AutoCAD SHX Text

GATE

AutoCAD SHX Text

GATE

AutoCAD SHX Text

GATE

AutoCAD SHX Text

CLF

AutoCAD SHX Text

GATE

AutoCAD SHX Text

CLF

AutoCAD SHX Text

ROOF DRAIN

AutoCAD SHX Text

GATE

AutoCAD SHX Text

BUILDING OVERHANG

AutoCAD SHX Text

CHILLER

AutoCAD SHX Text

GATE

AutoCAD SHX Text

GATE

AutoCAD SHX Text

GATE

AutoCAD SHX Text

GATE

AutoCAD SHX Text

CLF

AutoCAD SHX Text

GATE

AutoCAD SHX Text

1 STORY MASONRY BLDG FFE = 21.5

AutoCAD SHX Text

CLF

AutoCAD SHX Text

ROOF DRAIN

AutoCAD SHX Text

GATE

AutoCAD SHX Text

BUILDING OVERHANG

AutoCAD SHX Text

SEWER

AutoCAD SHX Text S

AutoCAD SHX Text

GATE

AutoCAD SHX Text

GATE

AutoCAD SHX Text

GATE

AutoCAD SHX Text

GATE

AutoCAD SHX Text

SHIPPING CONTAINER

AutoCAD SHX Text

GATE

AutoCAD SHX Text

1 STORY MASONRY BLDG FFE = 21.5

AutoCAD SHX Text

CLF

AutoCAD SHX Text

GATE

AutoCAD SHX Text

GATE

AutoCAD SHX Text

BIKE STORAGE

AutoCAD SHX Text

BUILDING OVERHANG

AutoCAD SHX Text

SEWER

AutoCAD SHX Text S

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

LIFT STATION AND HOUSING TO BE REMOVED

AutoCAD SHX Text

FENCE OR PIPE TO BE REMOVED

AutoCAD SHX Text

STRUCTURE OR OBJECT TO BE REMOVED

AutoCAD SHX Text

CONCRETE TO BE REMOVED

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY PAUL A. MANUEL, PE ON THE DATE ADJACENT TO THE SEAL. SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

GRAVITY SEWER

AutoCAD SHX Text

FORCE MAIN

AutoCAD SHX Text

FIRE MAIN

AutoCAD SHX Text

CONCRETE

AutoCAD SHX Text

BRICK PAVERS

AutoCAD SHX Text

LIFT STATION CONCRETE SLAB

AutoCAD SHX Text

CRUSHED SHELL

AutoCAD SHX Text

CHAIN LINK FENCE

AutoCAD SHX Text

TEMPORARY CONSTRUCTION FENCE

AutoCAD SHX Text

WATER LINE

AutoCAD SHX Text No. 51424. 51424.51424..

AutoCAD SHX Text

STATE OF

Sheets and Views
C2.0 Demo-Utility 24x36 FADE

File details come from the government source that posted it. Updated .