Asbestos-Containing Materials Summary
Aviano ES/MS/HS Wednesday, April 07, 2010
Asbestos-Containing Materials Summary
HOMO.
MATRL.
NO.
MATERIAL
TYPE
(MATERIAL
DESCRIPTION)
MATERIAL
LOCATION
(S)
QTY.
SAMPLE INFORMATION
FRI-
ABLE
OVERALL
CONDITION
TYPE OF
DAMAGE (IF
APPLICABLE)
POTENTIAL
FOR AIR
EROSION
POTENTIAL
VIBRATION
OVERALL
POTENTIAL
FOR
DAMAGE
RECOMMENDED
MANAGEMENT
ACTION(S)
MATERIAL
MANAGEMENT
PROCEDURE (IF
O&M)
ESTIMATED
COST COMMENTS
NUMBER DATE RESULT
BUILDING NUMBER: 151
215 ASPHALTIC
ROOFING
MATERIALS
(TAN, MODIFIED
BITUMEN)
ROOF
ABOVE
WINGS
(C207 AND
C206)
0 SFASSUMED ACM 8/3/2006 NO UNDAMAGED LOW LOW LOW
POTENTIAL
EXTERIOR
WEATHERPROOFING
MATERIALS
THIS MATERIAL WAS NOT SAMPLED DUE TO
POTENTIAL DAMAGE TO THE ROOF. ALL OF THE
COMPONENTS OF THIS ROOFING SYSTEM SHOULD BE
SAMPLED PRIOR TO RENOVATION OR REMOVAL OF
ANY PART OF THIS ROOF.
http://dashboard.dodeacorridor.com/comet_web/ahera/ahera.asp?frame=true&ID=27119&area=864568428&dist=1117827561&school=-1223025511&rptType=A [4/7/2010 2:46:14 PM] gina.romano Typewritten Text HE1280-11-R-0001 Exhibit G
Lajes ES/HS Wednesday, April 07, 2010
Asbestos-Containing Materials Summary
HOMO.
MATRL.
NO.
MATERIAL
TYPE
(MATERIAL
DESCRIPTION)
MATERIAL LOCATION(S) QTY.
SAMPLE INFORMATION
FRI-
ABLE
OVERALL
CONDITION
TYPE OF
DAMAGE (IF
APPLICABLE)
POTENTIAL
FOR AIR
EROSION
POTENTIAL
VIBRATION
OVERALL
POTENTIAL
FOR
DAMAGE
RECOMMENDED
MANAGEMENT
ACTION(S)
MATERIAL
MANAGEMENT
PROCEDURE (IF
O&M)
ESTIMATED
COST COMMENTS
NUMBER DATE RESULT
BUILDING NUMBER: 234
001 VINYL FLOOR
TILE
(9" X 9" GRAY)
301, 301A, 301C, 301D, 301E, 302, 302B, 303, 304, 306, 317, 401, 404, 405, 406, 406A, 406B, 406C, 407, 408, 408A, 408B, 408C, 412, 414
10,100 SF26888 6/19/1988 10% NO UNDAMAGED LOW LOW POTENTIAL VINYL FLOOR TILE
OR SHEETING
THE ADHESIVE FOR THIS MATERIAL IS MATERIAL
#095. THIS MATERIAL IS LOCATED UNDER VINYL
FLOOR TILE (MATERIAL #096) IN ROOM 412. THIS
MATERIAL IS LOCATED UNDER CARPET IN SOME
LISTED LOCATIONS.
26889 6/19/1988 5% CH
26900 6/19/1988 5% CH
005 CEILING PLASTER
(WHITE, 1/2"
THICK, WHITE
ROUGH
SURFACE, SOFT
TEXTURE)
301, 301D, 310, 310D, 406 17,200 SF0725-LEJ-001 7/25/1988 7-10% NO UNDAMAGED MEDIUM LOW POTENTIAL SURFACING
MATERIAL AND
WALL,CEILING OR
MISCELLANEOUS
TILES
THIS MATERIAL IS ALSO LOCATED ON THE UPPER
WALLS (ABOVE THE CEILING TILES) IN ROOM 301D.0725-LEJ-002 7/25/1988 10-15% CH
26863 6/19/1988 5% CH
26891 6/19/1988 5% CH
26892 6/19/1988 5% CH
26896 6/19/1988 0% No Data
26897 6/19/1988 5% CH
26898 6/19/1988 5% CH
008 FLEX CONNECTOR
(BLACK)
310D 1 EAASSUMED 6/17/1988 NO UNDAMAGED MEDIUM LOW POTENTIAL GASKET MATERIAL
AND FLEX
CONNECTORS
AT THE TIME OF THE 2000, 2003 AND 2006 AHERA
INSPECTION SURVEYS, THIS MATERIAL WAS NOT
ACCESSIBLE TO SAMPLE DUE TO ITS HEIGHT.
013 THERMAL
FITTING
INSULATION
PIPE CHASE B (BETWEEN ROOM 315 AND SHOWER AREA OF
ROOMS 315 AND 316),
PIPE CHASE F (BETWEEN SHOWERS OF ROOMS 315 AND 316),
PIPE CHASE H (BETWEEN SHOWERS AND TOILET OF ROOM 316)
31 EA26874 6/17/1988 40% YES UNDAMAGED LOW LOW LOW
POTENTIAL
PIPE OR PIPE
FITTING INSULATION
119 FITTINGS WERE REMOVED FROM PIPE CHASES A,
Y, AND X IN JULY 1992. THE REMAINING LOCATIONS
WERE NOT ACCESSIBLE FOR ADEQUATE INSPECTION
BY THE 1997, 2000, 2003 AND 2006 AHERA
INSPECTION TEAMS.
26875 6/17/1988 40% CH
26879 6/17/1988 70% CH
023 CEMENT
CORRUGATED
ROOF
(4' X 8' RED
SURFACE, GRAY
CORE)
ROOF B (ABOVE ROOMS 318 AND 319),
ROOF D (ABOVE CORRIDOR C114)
3,150 SF0726-LEJ-016 7/26/1988 3-5% NO UNDAMAGED MEDIUM LOW POTENTIAL ASBESTOS CEMENT
ITEMS
036 THERMAL PIPE
INSULATION
(ENCLOSED)
PIPE CHASE X (BETWEEN ROOMS S104.2 AND C204) 46 LF0726-LEJ-017 7/26/1988 35% YES UNDAMAGED LOW LOW POTENTIAL PIPE OR PIPE
FITTING INSULATION
46 LF OF PIPE INSULATION WERE ENCLOSED IN PIPE
CHASE X IN JULY 1992. AT THE TIME OF THE 2000,
2003 AND 2006 AHERA INSPECTIONS, THIS
PREVIOUSLY IDENTIFIED MATERIAL COULD NOT BE
ACCESSED DUE TO ITS LOCATION.
0726-LEJ-017 7/26/1988 30% CH
089 HEAT SHIELDS
(GRAY,
CEMENTITIOUS
BACKING PAD, IN
ELECTRICAL
SOCKET
OUTLETS)
302, 302B 6 EA0297-LAH-089A 2/19/1997 30-35% NO UNDAMAGED LOW LOW LOW
POTENTIAL
ASBESTOS CEMENT
ITEMS
THIS MATERIAL IS LOCATED UNDER SOME OF THE
METAL ELECTRICAL ACCESS PLATES IN THE FLOOR.
0297-LAH-089B 2/19/1997 30-35% CH
0297-LAH-089C 2/19/1997 20-35% CH
090 FLOOR ADHESIVE
(YELLOW AND
BLACK, UNDER
BLUE RUBBER
FLOOR
SHEETING)
308, 416 4,800 SF0297-LAH-090A 2/19/1997 1-2% NO UNDAMAGED LOW LOW LOW
POTENTIAL
FLOOR ADHESIVE
(MASTIC)
0297-LAH-090B 2/19/1997 1-2% CH
0297-LAH-090C 2/19/1997 1-2% CH
092 SINK COATING
(BLACK,
CEMENTITIOUS,
ON DOUBLE
BOWL)
301D 1 EA0297-LAH-092A 2/19/1997 3-5% NO UNDAMAGED LOW LOW POTENTIAL REMOVABLE ITEMS
0297-LAH-092B 2/19/1997 3-5% CH
0297-LAH-092C 2/19/1997 3-5% CH
093 VINYL FLOOR
TILE
(9" X 9" BLACK)
301D 78 SF0297-LAH-093A 2/19/1997 5-7% NO UNDAMAGED LOW LOW LOW
POTENTIAL
VINYL FLOOR TILE
OR SHEETING
THE ADHESIVE FOR THIS MATERIAL IS MATERIAL
#094. THIS MATERIAL IS LOCATED UNDER CARPET.0297-LAH-093B 2/19/1997 5-7% CH
0297-LAH-093C 2/19/1997 5-7% CH
094 FLOOR ADHESIVE
(BLACK, UNDER
9" X 9" BLACK
VINYL FLOOR
TILE)
301D 78 SF0297-LAH-094A 2/19/1997 3-5% NO UNDAMAGED LOW LOW LOW
POTENTIAL
FLOOR ADHESIVE
(MASTIC)
THIS IS THE ADHESIVE FOR MATERIAL #093.
0297-LAH-094B 2/19/1997 3-5% CH
0297-LAH-094C 2/19/1997 3-5% CH
095 FLOOR ADHESIVE
(BLACK, UNDER
9" X 9" GRAY
VINYL FLOOR
TILE)
301, 301A, 301C, 301D, 301E, 302, 302B, 303, 304, 306, 317, 401, 404, 405, 406, 406A, 406B, 406C, 407, 408, 408A, 408B, 408C, 412, 414
10,100 SF0297-LAH-095A 2/19/1997 10-15% NO UNDAMAGED LOW LOW LOW
POTENTIAL
FLOOR ADHESIVE
(MASTIC)
THIS IS THE ADHESIVE FOR MATERIAL #001.
0297-LAH-095B 2/19/1997 5-7% CH
0297-LAH-095C 2/19/1997 7-10% CH
101 TABLETOPS
(1" THICK, 3' X 6'
BLACK, SMOOTH
SURFACE, BLACK
CORE)
307, 409, 410 32 EA0297-LAH-101A 2/19/1997 10-15% NO UNDAMAGED LOW LOW POTENTIAL ASBESTOS CEMENT
ITEMS
THIS MATERIAL IS LOCATED ON TEACHERS TABLE, LAB
HOOD TABLES, AND WALL MOUNTED WORK TABLES.
0297-LAH-101B 2/19/1997 10-15% CH
0297-LAH-101C 2/19/1997 10-15% CH
103 LABORATORY
FUME HOODS
(GRAY,
CEMENTITIOUS
BOARD,
SCREWED-ON)
307, 409 2 EA0297-LAH-103A 2/19/1997 20-25% NO UNDAMAGED LOW LOW POTENTIAL ASBESTOS CEMENT
ITEMS
0297-LAH-103B 2/19/1997 20-25% CH
0297-LAH-103C 2/19/1997 20-25% CH
113 SHEET GASKET
(GRAY, ON PIPE
FLANGE
CONNECTIONS)
016 26 EA0297-LAH-113A 2/19/1997 60-65% NO UNDAMAGED LOW LOW LOW
POTENTIAL
GASKET MATERIAL
AND FLEX
CONNECTORS0297-LAH-113B 2/19/1997 60-65% CH
0297-LAH-113C 2/19/1997 60-65% CH
119 FLOOR ADHESIVE
(WHITE, UNDER
GRAY RUBBER
FLOOR
SHEETING)
310, 416, S102.1, S102.2, S106.1, S106.2 0 SF0300-LAH-119A 3/24/2000 1-3% NO UNDAMAGED LOW LOW LOW
POTENTIAL
FLOOR ADHESIVE
(MASTIC)
0300-LAH-119B 3/24/2000 1-3% CH
0300-LAH-119C 3/24/2000 1-3% CH
121 FLOOR ADHESIVE
(YELLOW,
UNDER 1' X 1'
BLUE MOTTLED
WITH GRAY
307, 309 0 SF0300-LAH-121A 3/24/2000 1-2% NO UNDAMAGED LOW LOW LOW
POTENTIAL
FLOOR ADHESIVE
(MASTIC)
THIS IS THE ADHESIVE FOR MATERIAL #120.
0300-LAH-121B 3/24/2000 ND
http://dashboard.dodeacorridor.com/comet_web/ahera/ahera.asp?fram...&ID=47&area=864568428&dist=1117827561&school=-245464271&rptType=A (1 of 2) [4/7/2010 2:47:28 PM]
VINYL FLOOR
TILE) 0300-LAH-121C 3/24/2000 1-3% CH
126 ROPE GASKET
(WHITE)
016 0 LF0300-LAH-126A 3/24/2000 60-65% NO UNDAMAGED LOW LOW LOW
POTENTIAL
GASKET MATERIAL
AND FLEX
CONNECTORS
THIS MATERIAL IS LOCATED ON THE INTERIOR OF THE
FURNACE BEHIND THE GREEN SHEET METAL WALLS OF
H.B. SMITH BOILER.
0300-LAH-126B 3/24/2000 60-65% CH
0300-LAH-126C 3/24/2000 60-65% CH
135 TABLETOPS
(3/4" THICK, 3' X
5' BLACK,
SMOOTH
SURFACE, BLACK
CORE)
306 0 EA0403-LAH-135A 4/3/2003 15% NO UNDAMAGED LOW LOW POTENTIAL ASBESTOS CEMENT
ITEMS
THIS MATERIAL IS LOCATED ON DESK TABLES WITH
WOOD LEGS.
0403-LAH-135B 4/3/2003 20% CH
0403-LAH-135C 4/3/2003 20% CH
138 CEILING TILE
ADHESIVE
(UNDER 1' X 1'
WHITE, CORK
CORE CEILING
TILES)
016 0 SFASSUMED ACM 4/23/2003 NO UNDAMAGED LOW LOW LOW
POTENTIAL
FLOOR ADHESIVE
(MASTIC)
THIS IS THE ADHESIVE FOR MATERIAL #011. THIS
MATERIAL COULD NOT BE SAMPLED WITHOUT
DAMAGE TO THE CEILING TILE.
152 ASPHALTIC
ROOFING
MATERIALS
(BLACK, BUILT-
UP ROOF)
ROOF C (ABOVE SHOWERS OF ROOMS 315 AND 316) 0 SFASSUMED ACM 6/27/2006 NO UNDAMAGED LOW LOW POTENTIAL EXTERIOR
WEATHERPROOFING
MATERIALS
THIS MATERIAL WAS NOT SAMPLED DUE TO
POTENTIAL DAMAGE TO THE ROOF. ALL OF THE
COMPONENTS OF THIS ROOFING SYSTEM SHOULD BE
SAMPLED PRIOR TO RENOVATION OR REMOVAL OF
ANY PART OF THIS ROOF.
BUILDING NUMBER: 294
056 SINK COATING
(BLACK,
CEMENTITIOUS,
ON DOUBLE
BOWL)
101 10 EA0394-LAH-056A 3/2/1994 3-5% NO UNDAMAGED LOW LOW POTENTIAL REMOVABLE ITEMS
0394-LAH-056B 3/2/1994 5-7% CH
0394-LAH-056C 3/2/1994 3-5% CH
http://dashboard.dodeacorridor.com/comet_web/ahera/ahera.asp?fram...&ID=47&area=864568428&dist=1117827561&school=-245464271&rptType=A (2 of 2) [4/7/2010 2:47:28 PM]
Livorno ES/HS Wednesday, April 07, 2010
Asbestos-Containing Materials Summary
HOMO.
MATRL.
NO.
MATERIAL
TYPE
(MATERIAL
DESCRIPTION)
MATERIAL
LOCATION
(S)
QTY.
SAMPLE INFORMATION
FRI-
ABLE
OVERALL
CONDITION
TYPE OF
DAMAGE (IF
APPLICABLE)
POTENTIAL
FOR AIR
EROSION
POTENTIAL
VIBRATION
OVERALL
POTENTIAL
FOR
DAMAGE
RECOMMENDED
MANAGEMENT
ACTION(S)
MATERIAL
MANAGEMENT
PROCEDURE
(IF O&M)
ESTIMATED
COST COMMENTS
NUMBER DATE RESULT
BUILDING NUMBER: 201
071 OTHER MACM
(GRAY,
CEMENTITIOUS
TANK)
118 0 SF0300-LIE-071A 3/9/2000 2% NO UNDAMAGED LOW LOW LOW
POTENTIAL
REMOVABLE
ITEMS
THIS MATERIAL IS LOCATED ON ONE 3' DIAMETER X 6'
HIGH TANK IN THE LOFT ABOVE THE STAGE.0300-LIE-071A 3/9/2000 20% CH
0300-LIE-071B 3/9/2000 2% CR
0300-LIE-071B 3/9/2000 20% CH
0300-LIE-071C 3/9/2000 20% CH
0300-LIE-071C 3/9/2000 2% CR
072 OTHER MACM
(GRAY,
CEMENTITIOUS
TUB)
118 0 SF0300-LIE-072A 3/9/2000 20% NO DAMAGED PHYSICAL LOW LOW LOW
POTENTIAL
REMOVABLE
ITEMS
THIS MATERIAL IS LOCATED ON A 2' X 2' X 2' TUB IN
THE LOFT ABOVE THE STAGE. 4 SF OF THIS MATERIAL,
THE LID FOR THE TUB, ARE DAMAGED AND NEED TO
BE REMOVED.
0300-LIE-072A 3/9/2000 1% CR
0300-LIE-072B 3/9/2000 20% CH
0300-LIE-072B 3/9/2000 2% CR
0300-LIE-072C 3/9/2000 2% CR
0300-LIE-072C 3/9/2000 20% CH
BUILDING NUMBER: 501
004 CEMENT PIPE
(5" DIAMETER,
WHITE)
204 10 LF0311-LIH-004 3/11/1991 3-5% NO UNDAMAGED LOW LOW POTENTIAL ASBESTOS
CEMENT ITEMS0311-LIH-004 3/11/1991 20% CH
27199 6/22/1988 5% CH
032 DUST/DEBRIS
(GRAY,
CEMENTITIOUS)
M101, M105 3 SF0311-LIH-032 3/11/1991 20% YES SIGNIFICANT
DAMAGE
PHYSICAL HIGH LOW SIGNIFICANT
POTENTIAL
ASBESTOS DUST/
DEBRIS
ALL OF THIS MATERIAL IS DAMAGED AND NEEDS TO
BE REMOVED.
0311-LIH-032 3/11/1991 40-45% CH
036 ROPE GASKET
(WHITE, ON
BOILER DOORS)
M101 20 EA0311-LIH-036 3/11/1991 70-75% NO UNDAMAGED LOW LOW LOW
POTENTIAL
GASKET
MATERIAL AND
FLEX
CONNECTORS
ONE IS LOCATED ON THE FRONT AND ONE IS LOCATED
ON THE BACK OF THE BOILER.
082 SHEET GASKET
(4" DIAMETER,
CREAM)
M101 2 EA0297-LIV-082A 2/7/1997 20-25% NO UNDAMAGED LOW LOW LOW
POTENTIAL
GASKET
MATERIAL AND
FLEX
CONNECTORS
THIS MATERIAL IS LOCATED ON TOP OF BOILER.
0297-LIV-082B 2/7/1997 20-25% CH
0297-LIV-082C 2/7/1997 20-25% CH
100 SINK COATING
(WHITE,
SPRAYED-ON)
101 0 EA1103-LIV-100A 11/18/2003 5% NO UNDAMAGED LOW LOW POTENTIAL REMOVABLE
ITEMS1103-LIV-100B 11/18/2003 5% CH
1103-LIV-100C 11/18/2003 8% CH
BUILDING NUMBER: 504
002 CEMENT
ROOFING PANELS
(3' X 3-1/2'
GRAY,
CORRUGATED)
106A 11 SF0119-LIV-030 1/19/1989 15% NO DAMAGED PHYSICAL LOW LOW POTENTIAL ASBESTOS
CEMENT ITEMS
ALL OF THIS MATERIAL IS DAMAGED AND NEEDS TO
BE REMOVED.0119-LIV-030 1/19/1989 5% CR
27212 6/22/1988 10% CR
27212 6/22/1988 20% CH
27213 6/22/1988 15% CH
27213 6/22/1988 10% CR
038 ROPE GASKET
(WHITE, ON
BOILER DOOR)
M101 10 EA0311-LIH-038 3/11/1991 60-65% YES UNDAMAGED LOW LOW LOW
POTENTIAL
GASKET
MATERIAL AND
FLEX
CONNECTORS
040 SHEET GASKET
(WHITE, ON PIPE
FLANGE
CONNECTIONS)
M101 9 EA1193-LIH-040A 11/29/1993 50-55% NO UNDAMAGED LOW LOW LOW
POTENTIAL
GASKET
MATERIAL AND
FLEX
CONNECTORS
1193-LIH-040B 11/29/1993 60-65% CH
1193-LIH-040C 11/29/1993 30-35% CH
http://dashboard.dodeacorridor.com/comet_web/ahera/ahera.asp?frame=true&ID=69&area=864568428&dist=1117827561&school=-1309026136&rptType=A [4/7/2010 2:48:25 PM]
Wednesday, April 07, 2010
Asbestos-Containing Materials Summary
HOMO.
MATRL.
NO.
MATERIAL
TYPE
(MATERIAL
DESCRIPTION)
MATERIAL
LOCATION
(S)
QTY.
SAMPLE INFORMATION
FRI-
ABLE
OVERALL
CONDITION
TYPE OF
DAMAGE (IF
APPLICABLE)
POTENTIAL
FOR AIR
EROSION
POTENTIAL
VIBRATION
OVERALL
POTENTIAL
FOR
DAMAGE
RECOMMENDED
MANAGEMENT
ACTION(S)
MATERIAL
MANAGEMENT
PROCEDURE (IF
O&M)
ESTIMATED
COST COMMENTS
NUMBER DATE RESULT
BUILDING NUMBER: 307
040 SHEET GASKET
(2" - 6"
DIAMETER,
WHITE, ON
VALVE FLANGE
CONNECTIONS)
107 58 EA1193-VIC-040A 11/17/1993 50-55% NO UNDAMAGED LOW LOW LOW
POTENTIAL
GASKET MATERIAL
AND FLEX
CONNECTORS1193-VIC-040B 11/17/1993 60-65% CH
1193-VIC-040C 11/17/1993 60-65% CH
209 ASPHALTIC
ROOFING
MATERIALS
(GRAY,
MODIFIED
BITUMEN)
ROOF 0 SFASSUMED ACM 8/8/2006 NO UNDAMAGED LOW LOW LOW
POTENTIAL
EXTERIOR
WEATHERPROOFING
MATERIALS
THIS MATERIAL WAS NOT SAMPLED DUE TO
POTENTIAL DAMAGE TO THE ROOF. ALL OF THE
COMPONENTS OF THIS ROOFING SYSTEM SHOULD BE
SAMPLED PRIOR TO RENOVATION OR REMOVAL OF
ANY PART OF THIS ROOF.
212 CEMENT PIPE
(6' -12"
DIAMETER,
GRAY, SEWER
PIPE)
BUILDING
EXTERIOR
0 LFASSUMED ACM 8/8/2006 NO UNDAMAGED LOW LOW LOW
POTENTIAL
ASBESTOS CEMENT
ITEMS
THIS MATERIAL IS LOCATED UNDERGROUND (4' TO 5'
DEEP) BETWEEN THE DSO AND THE VINCENZA SCHOOL
COMPLEX. AT THE TIME OF 2006 AHERA INSPECTION,
A PORTION OF THIS MATERIAL WAS EXPOSED DUE TO
THE CURRENT EXCAVATION. A LARGER QUANTITY OF
PIPE MAY EXIST THAN OBSERVED BY THE INSPECTION
TEAM.
http://dashboard.dodeacorridor.com/comet_web/ahera/ahera.asp?frame=true&ID=56121&area=864568428&dist=1117827561&school=1203351033&rptType=A [4/7/2010 2:39:32 PM]
Sevilla ES Wednesday, April 07, 2010
Asbestos-Containing Materials Summary
HOMO.
MATRL.
NO.
MATERIAL
TYPE
(MATERIAL
DESCRIPTION)
MATERIAL
LOCATION
(S)
QTY.
SAMPLE INFORMATION
FRI-
ABLE
OVERALL
CONDITION
TYPE OF
DAMAGE (IF
APPLICABLE)
POTENTIAL
FOR AIR
EROSION
POTENTIAL
VIBRATION
OVERALL
POTENTIAL
FOR
DAMAGE
RECOMMENDED
MANAGEMENT
ACTION(S)
MATERIAL
MANAGEMENT
PROCEDURE (IF
O&M)
ESTIMATED
COST COMMENTS
NUMBER DATE RESULT
BUILDING NUMBER: 0314 (1973)
001 THERMAL PIPE
INSULATION
(4" DIAMETER,
WHITE, FIBROUS
BLOCK
INSULATION, ON
HOT WATER
LINES)
PIPE CHASE
A, PIPE CHASE B
30 LF00026 6/24/1987 0% YES UNDAMAGED LOW LOW LOW
POTENTIAL
PIPE OR PIPE
FITTING INSULATION
AT THE TIME OF THE 2006 AHERA INSPECTION, THIS
MATERIAL WAS NOT ACCESSIBLE FOR INSPECTION.00084 6/24/1987 <1% CH
00374 6/24/1987 0% No Data
1121-MOR-002A 11/21/1989 20% CH
1121-MOR-002B 11/21/1989 15% AM
1121-MOR-002B 11/21/1989 15% CH
1121-MOR-002C 11/21/1989 10% AM
1121-MOR-002C 11/21/1989 20% CH
007 SHEET GASKET
(2"-4"
DIAMETER,
WHITE, ON PIPE
FLANGE
CONNECTIONS)
PIPE CHASE
A, PIPE CHASE B
4 EA0897-NHS-007A 8/21/1997 ND None NO UNDAMAGED LOW LOW LOW
POTENTIAL
GASKET MATERIAL
AND FLEX
CONNECTORS
AT THE TIME OF THE 2006 AHERA INSPECTION, THIS
MATERIAL WAS NOT ACCESSIBLE FOR INSPECTION.0897-NHS-007B 8/21/1997 ND
0897-NHS-007C 8/21/1997 ND
1122-MOR-004 11/22/1989 15% CH
1122-MOR-004 11/22/1989 10% CR
014 CEMENT PIPE
(6" DIAMETER,
GRAY)
103 15 LF1105-SEE-014 11/5/1990 40-50% NO UNDAMAGED LOW LOW POTENTIAL ASBESTOS CEMENT
ITEMS
1105-SEE-014 11/5/1990 15-35% CR
018 THERMAL
FITTING
INSULATION
(4" DIAMETER,
WHITE, FIBROUS)
PIPE CHASE
A, PIPE CHASE B
8 EA1121-MOR-003A 11/21/1989 0% YES UNDAMAGED LOW LOW LOW
POTENTIAL
PIPE OR PIPE
FITTING INSULATION
AT THE TIME OF THE 2006 AHERA INSPECTION, THIS
MATERIAL WAS NOT ACCESSIBLE FOR INSPECTION.1121-MOR-003B 11/21/1989 15% AM
1121-MOR-003B 11/21/1989 15% CR
1121-MOR-003B 11/21/1989 15% CH
1121-MOR-003C 11/21/1989 15% CR
1121-MOR-003C 11/21/1989 15% AM
1121-MOR-003C 11/21/1989 15% CH
039 ASPHALTIC
ROOFING
MATERIALS
(BUILT-UP ROOF
WITH CRUSHED
GRAVEL)
ATTIC 1,
ATTIC 2,
ATTIC 3
0 SFASSUMED ACM 6/14/2006 NO UNDAMAGED LOW LOW POTENTIAL EXTERIOR
WEATHERPROOFING
MATERIALS
THIS MATERIAL WAS NOT SAMPLED DUE TO
POTENTIAL DAMAGE TO THE ROOF. ALL OF THE
COMPONENTS OF THIS ROOFING SYSTEM SHOULD BE
SAMPLED PRIOR TO RENOVATION OR REMOVAL OF
ANY PART OF THIS ROOF. DUE TO THE INSTALLATION
OF A NEW METAL ROOF, THIS PREVIOUS ROOFING
MATERIAL IS NOW THE FLOOR MATERIAL OF THE
ATTIC (ATTICS 1, 2, AND 3).
http://dashboard.dodeacorridor.com/comet_web/ahera/ahera.asp?frame=true&ID=26228&area=864568428&dist=1117827561&school=-196408190&rptType=A [4/7/2010 2:50:10 PM]
Vicenza ES/HS Wednesday, April 07, 2010
Asbestos-Containing Materials Summary
HOMO.
MATRL.
NO.
MATERIAL
TYPE
(MATERIAL
DESCRIPTION)
MATERIAL
LOCATION
(S)
QTY.
SAMPLE INFORMATION
FRI-
ABLE
OVERALL
CONDITION
TYPE OF
DAMAGE (IF
APPLICABLE)
POTENTIAL
FOR AIR
EROSION
POTENTIAL
VIBRATION
OVERALL
POTENTIAL
FOR
DAMAGE
RECOMMENDED
MANAGEMENT
ACTION(S)
MATERIAL
MANAGEMENT
PROCEDURE (IF
O&M)
ESTIMATED
COST COMMENTS
NUMBER DATE RESULT
BUILDING NUMBER: 309
011 SHEET GASKET
(2" - 6"
DIAMETER,
WHITE, ON
VALVE FLANGE
CONNECTIONS)
3A, 46, 59, 59A
55 EA08067 4/1/1988 27% NO UNDAMAGED LOW LOW LOW
POTENTIAL
GASKET MATERIAL
AND FLEX
CONNECTORS
051 DUCT
INSULATION
(BLACK, TAR
PAPER)
201 3,300 SF0218-VIC-051A 2/18/1991 1-2% YES UNDAMAGED LOW MEDIUM POTENTIAL VENTILATION DUCT
INSULATION
* SAMPLE WAS REANALYZED USING SEM TECHNIQUES.
THE RESULT OF THE ANALYTICAL TEST WAS GREATER
THAN 1% ASBESTOS. THIS MATERIAL IS CONSIDERED
TO BE ACM.
0218-VIC-051A 2/18/1991 2.11% CH*
0218-VIC-051B 2/18/1991 1-2% CH
0218-VIC-051B 2/18/1991 1.82% CH*
0218-VIC-051C 2/18/1991 1-2% CH
0218-VIC-051C 2/18/1991 2.66% CH*
056 SHEET GASKET
(2" - 6"
DIAMETER,
WHITE, ON
VALVE FLANGE
CONNECTIONS)
30E, 32, 34 21 EA1193-VIC-056A 11/15/1993 60-65% NO UNDAMAGED LOW LOW POTENTIAL GASKET MATERIAL
AND FLEX
CONNECTORS1193-VIC-056B 11/15/1993 60-65% CH
1193-VIC-056C 11/15/1993 60-65% CH
073 FLOOR ADHESIVE
(BLACK, UNDER
TWO TYPES OF
1' X 1' LIGHT
GREEN VINYL
FLOOR TILES
AND FADED
GREEN VINYL
FLOOR
SHEETING)
108, 110, 111, 113, 115, 117, 119, 121, 122C, 123, 125, 126, 127, 129, 13, 138, 140, 141, 15, 17, 19, 28, 56, 56A, 58, 60
17,255 SF1109-VIC-021A 11/9/1988 5% NO UNDAMAGED LOW LOW LOW
POTENTIAL
FLOOR ADHESIVE
(MASTIC)
THIS IS THE ADHESIVE FOR MATERIALS #006, #159,
AND #169.
1109-VIC-021B 11/9/1988 3-5% CH
1109-VIC-021C 11/9/1988 3-5% CH
159 VINYL FLOOR
TILE
(1' X 1' LIGHT
GREEN)
108, 110, 111, 113, 115, 117, 119, 121, 122C, 123, 125, 126, 127, 129, 13, 15, 17, 15,155 SF08018 4/1/1988 5% NO UNDAMAGED LOW LOW LOW
POTENTIAL
VINYL FLOOR TILE
OR SHEETING
THE ADHESIVE FOR THIS MATERIAL IS MATERIAL
#073. THIS MATERIAL IS LOCATED BELOW THE
EXISTING CARPET AND/OR FLOORING MATERIALS.
161 VINYL FLOOR
TILE
(8" X 8" GREEN)
101, 102, 104, 106, 106A, 106B, 109, 11, 19A, 2, 3, 3A, 4, 6
8,800 SF05816 4/1/1988 5% NO UNDAMAGED LOW LOW POTENTIAL VINYL FLOOR TILE
OR SHEETING
THE ADHESIVE FOR THIS MATERIAL IS MATERIAL
#074. THIS MATERIAL IS LOCATED BELOW THE
EXISTING CARPET AND/OR FLOORING MATERIALS.
05817 4/1/1988 4% CH
165 SHEET GASKET
(2" - 6"
DIAMETER, TAN,
ON VALVE
FLANGE
CONNECTIONS)
M101 44 EA1193-VIC-13EA 11/17/1993 60-65% NO UNDAMAGED LOW LOW LOW
POTENTIAL
GASKET MATERIAL
AND FLEX
CONNECTORS1193-VIC-13EB 11/17/1993 60-65% CH
1193-VIC-13EC 11/17/1993 60-65% CH
169 VINYL FLOOR
SHEETING
(FADED GREEN)
28 1,700 SF05820 4/1/1988 6% NO UNDAMAGED LOW LOW LOW
POTENTIAL
VINYL FLOOR TILE
OR SHEETING
THE ADHESIVE FOR THIS MATERIAL IS MATERIAL
#073. THIS MATERIAL IS LOCATED BELOW THE
EXISTING CARPET AND/OR FLOORING MATERIALS.
203 SINK COATING
(GRAY, SPRAYED-
ON)
10, 4, 53, 56 0 EA1103-VHS-203A 11/12/2003 5% NO UNDAMAGED LOW LOW POTENTIAL REMOVABLE ITEMS
1103-VHS-203B 11/12/2003 5% CH
1103-VHS-203C 11/12/2003 5% CH
221 ASPHALTIC
ROOFING
MATERIALS
(GRAY,
MODIFIED
BITUMEN ROOF)
ROOF 0 SFASSUMED ACM 8/9/2006 NO UNDAMAGED LOW LOW LOW
POTENTIAL
EXTERIOR
WEATHERPROOFING
MATERIALS
THIS MATERIAL WAS NOT SAMPLED DUE TO
POTENTIAL DAMAGE TO THE ROOF. ALL OF THE
COMPONENTS OF THIS ROOFING SYSTEM SHOULD BE
SAMPLED PRIOR TO RENOVATION OR REMOVAL OF
ANY PART OF THIS ROOF.
BUILDING NUMBER: 367
038 SHEET GASKET
(2" - 6"
DIAMETER, TAN)
M101 49 EA1193-VIC-038A 11/17/1993 60-65% NO UNDAMAGED LOW LOW LOW
POTENTIAL
GASKET MATERIAL
AND FLEX
CONNECTORS
1193-VIC-038B 11/17/1993 60-65% CH
1193-VIC-038C 11/17/1993 60-65% CH