Exhibit F4 - Portugal Facility Report.pdf

PDF 29 KB Posted

Attached to
HE1280-11-R-0001 Mediterranean School Maintenance Program (MSMP)
Solicitation number
he1280-11-r-0001
Issued by

About this file

Exhibit F4 - Portugal Facility Report

View the file

Other files

File Type Posted
Exhibit R - Non-Routine Pricing Spreadsheets Amend6.xlsx XLSX spreadsheet
HE1280-11-R-0001 Amendment 0006.pdf PDF
Attachment 10 - Responses to Industry not provided in Attachment 9 - Amend6.pdf PDF
Exhibit H - Installed Equipment Summary.pdf PDF
Exhibit R - Non-Routine Pricing Spreadsheets Amend5.xlsx XLSX spreadsheet
HE1280-11-R-0001 Amendment 0005.pdf PDF
HE1280-11-R-0001 Amendment 0004.pdf PDF
Attachment 9 - Responses to Questions-Comments from Industry - Final Solicitation.pdf PDF
HE1280-11-R-0001 Amendment 0003.pdf PDF
Exhibit R - Non-Routine Pricing Spreadsheets Amend3.xlsx XLSX spreadsheet
HE1280-11-R-0001 Amendment 0002.pdf PDF
HE1280-11-R-0001-0001_Amend__MSMP.pdf PDF
Exhibit E1 - Aviano EMHS.pdf PDF
Exhibit H - Installed Equipment Summary.pdf PDF
Exhibit Q2 - Livorno Facility Utilization Survey Data Plans.pdf PDF
Exhibit F1 - Q Ratings.pdf PDF
Exhibit F2 - Italy Facility Report.pdf PDF
Attachment 3 - MSMP Past Performance Certification.docx DOCX document
Exhibit U - Historical Routine Services.pdf PDF
Exhibit A - Med District Regional Maps.pdf PDF
Exhibit P - Elementary School Education Specifications.pdf PDF
Exhibit Q4 - Sigonella Facility Utilization Survey Data Plans.pdf PDF
Exhibit E8 - Mediterranean DSO.pdf PDF
Exhibit N - SchoolDude WorkOrderProcess.pdf PDF
Exhibit Q1 - Aviano Facility Utilization Survey Data Plans.pdf PDF
Attachment 2 - PAST_PERFORMANCE_QUESTIONNAIRE.doc DOC document
ATTACHMENT 4B - SF 1035 Continuation Sheet.pdf PDF
Exhibit L - Occupancy Data 2010.pdf PDF
Exhibit C - Official School Addresses.pdf PDF
Attachment 8 - MSMP PreProposal Conference Slides.pdf PDF
Exhibit K - DoDDS School Calendar 10-11 and 11-12.pdf PDF
Exhibit F3 - Spain Facility Report.pdf PDF
Attachment 1 - Seed Project.pdf PDF
Exhibit Q8 - Med DSO Facility Utilization Survey Data Plans.pdf PDF
Attachment 6 - Responses to Questions-Comments from Industry 1st Draft Solicitation.pdf PDF
Exhibit E4 - Sigonella ESMSHS.pdf PDF
HE1280-11-R-0001 FINAL.pdf PDF
ATTACHMENT 4A - SF 1034 Public Voucher.pdf PDF
Exhibit T - Historical Non-Routine Financial Data.pdf PDF
Exhibit Q5 - Rota Facility Utilization Survey Data Plans.pdf PDF
Exhibit E3 - Livorno EMS.pdf PDF
Exhibit B - Driving Directions.pdf PDF
Exhibit R - Non-Routine Pricing Spreadsheets Final.xlsx XLSX spreadsheet
Exhibit J - Project Workload Other than Routine Services.pdf PDF
Exhibit Q6 - Seville Facility Utilization Survey Data Plans.pdf PDF
Exhibit Q3 Vicenza Facility Utilization Survey Data Plans.pdf PDF
Exhibit D - Med District Areas.pdf PDF
Attachment 5 - Quality Assurance Surveillance Plan.pdf PDF
Exhibit M - Government Furnished Facilities.pdf PDF
Cover Letter HE1280-11-R-0001 Final Solicitation.pdf PDF
Show 40 more

Latest 50 of 59 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Lajes – Facility Information Building Num Year Built Q-Rating Lajes ES/HS Bldg 234 1956 Q1 Lajes ES/HS Bldg 294 1973 Q4

General Facilities Description Site: Lajes Elementary/High School is located at Lajes Field, Azores, near the Nacer do Sol Military Family Housing Area. Parking areas are generally constructed using concrete while sidewalks are typically constructed using concrete. The school has a parking capacity of approximately 14. Site drainage is generally adequate.

Playgrounds: The campus contains 3 play groups. Play equipment includes 4 composite structures, 2 single-axis swings, and other miscellaneous equipment. Playground equipment generally complies with provisions of the U.S. Consumer Product Safety Commission, Handbook for Public Playground Safety. Most playground equipment is installed on protective surfacing. Typical deficiencies observed include inadequate protective surfacing, entanglements, and deteriorated wood and metal surfaces.

Structural/Exterior Closure: We found some signs of damage to foundations during the course of the assessment. In addition, exterior walls showed some signs of of water penetration, and there was some minor damage. Roof coverings include cement asbestos panels and modified bitumen with some minor leaks reported. Exterior doors and windows are generally weather tight.

Interiors: Partition walls are generally painted masonry with some painted drywall. Ceilings in classroom and office areas are generally suspended acoustical tile. The ceilings in the gymnasiums are exposed structure. Flooring in high traffic areas is typically ceramic tile while carpet is used in most classrooms and offices.

NFPA 101, Life Safety Code: Corridors and stairwells generally comply with provisions of NFPA 101. Assembly spaces generally comply with egress requirements. Fire sprinkler systems are not present in any campus facilities. The campus has a fire alarm system which is activated by smoke sensors and pull stations and automatically reports to the fire department upon activation. Emergency lighting is not present at all required locations. Exit signs appear to be present at all required locations. Typical deficiencies include doors leading to corridors do not have closers, doors leading to corridors have vents, visual alarms are not present, and panic hardware missing at egress doors.

American with Disabilities Act (ADA): The campus is generally ADA compliant. The parking area does not contain the required number of accessible parking spaces. Exterior routes of travel are generally ADA compliant. The building has an accessible entrance.

Typical deficiencies include classroom door hardware is not ADA compliant, handrails at toilets are not compliant, lavatories are not compliant, no strobes on fire alarms, and stair handrails are inadequate.

Mechanical: Heating and cooling are provided by a combination of through-wall heat pumps and split units. Ventilation in restrooms is generally inadequate. Campus facilities have air conditioning with dedicated air conditioning for all LAN concentrator rooms. The campus has no elevators but has several chair lifts between floors.

Electrical: Minor electrical upgrades have been installed to support the computer network, but most wiring appears to be original.

Lighting is typically fluorescent with limited use of incandescent. Ground-fault circuit interrupter (GFCI) receptacles appear to be present in all required locations. The campus has an intercom system but does not have a remote handset for use during fire drills or emergency evacuations. The campus does not have a functional security system but does have a limited number of security cameras.

Plumbing: Plumbing fixtures have been partially upgraded and piping appears to be original. Domestic hot water is provided by a combination of oil-fired boilers and electric water heaters.

gina.romano Typewritten Text

HE1280-11-R-0001

Exhibit F4 Portugal Facility Report

File details come from the government source that posted it. Updated .