ASBESTOS
SURVEY REPORT
For
911 BUILDING
General Information 1.1 Inspection Summary 1.2 Photographs 2.1 Asbestos Survey Drawing ASB.1 Sample Inventories 3.1 Laboratory Data Not Numbered AHERA Certificates Not Numbered NVLAP Certificates Not Numbered
Prepared By
May 2001
PBS ENVIRONMENTAL
1220 SW Morrison St. #600
Portland, OR 97205
(503) 248-1939
PBS Project No. 15273.016
GENERAL INFORMATIONGeneral Services Administration
911 NE 11th Avenue
BUILDING DATA
911 Building
Portland, OR
CLIENT DATA
General Services Administration Project Services, 10PC Auburn, WA 98001-6599
• The type, location and approximate quantity of suspect asbestos-containing materials;
• Bulk sampling of selected suspect building materials;
• Laboratory analytical data of bulk materials sampled
SURVEY SCOPE
PBS endeavored to locate all the suspect asbestos-containing materials in the building; however, suspect asbestos-containing materials may be present concealed within wall, ceiling, or floor spaces. If suspect materials are uncovered during demolition activities that are not identified in this report, testing should be performed prior to impact.
PBS has conducted a physical inspection of the building, compiled this report consistent with the survey scope, and certifies that the information is correct and accurate within the standards of professional quality and contractual obligations.
PBS Engineering and Environmental has performed a general asbestos survey of accessible building areas in accordance with OSHA in 29 CFR 1910.1001 and compiled a report with the following information:
911 Building1.1 January 2004 PBS Project No: 15273.016
Rich DufresneRon Petti
IR-03-1084MPR-02-2680
DateSignature
Project Manager Prime Inspector
DateSignature
Accreditation #: Accreditation #:
PBS Engineering and Environmental
INSPECTION SUMMARYGeneral Services Administration
The following materials tested negative based on ASHARA sampling minimums and testing by NVLAP participating laboratories.
Although no asbestos was detected, it is possible that further sampling could indicate asbestos content. It may be prudent to test prior to impact through demolition, renovation, etc.
4/26/2001 Rich Dufrense 4/27/2001 Rich Dufresne
DATES SURVEYED BY ACTIVITY
Inspect and Sample Inspect and Sample
PBS Engineering and Environmental has investigated accessible areas inside of the building(s) to locate suspect asbestos-containing building materials (ACBM). Suspect materials may be present in concealed areas (e.g. behind walls and under carpet). The findings are listed below.
ASBESTOS MATERIALS
The following materials either tested positive, or, based on the experience of PBS field personnel, were not tested and should be considered asbestos-containing. Materials that had mixed results are considered positive. Materials not sampled may not contain asbestos and should be tested to verify asbestos content prior to impact through demolition, renovation, etc.
(+) Tested Positive, (M) Mixed Results, (P) Presumed Positive, (T) Previously Tested Positive.
Approx. Quantit
MATERIALS WHICH TESTED NEGATIVE FOR ASBESTOS
Type Material Location
Material Location
East and West Stairwell Landings, Mechanical rooms.
Floor Coating(+)
Microwave Equip.
Room, Sub-Basement Break Room, Closets, Electrical Rooms.
Vinyl Floor Tile(+)
3 EABasement Fan Room, Elevator Shaft
Hard Fittings/Fiberglass(P)
200 SFElevator Equipment Room
Electrical Mounting Boards(+)
1,000 SFBlack Coating on Exterior of Elevator Cars
Coating(+)
10 EAElevator Equipment Room, on Elevator Hoists
Brake Pads(+)
Lining Inside Elevator Doors
Fire Door Lining(+)
Gypsum and Plaster Walls and Ceilings Throughout Lay-in Ceiling Tile Throughout Sprayed Fibrous Fireproofing Basement levels Troweled-on Fireproofing Throughout
911 Building1. 2 January 2004 PBS Project No: 15273.016
Asbestos bulk samples obtained from these buildings were collected by an EPA AHERA accredited inspector and analyzed using Polarized Light Microscopy (PLM) with dispersion staining. The results of the analysis are presented in a separate section of this report. See the inspection summary for additional information.
Various types of Vinyl Floor Tile Storage Rooms, Basement Rooms
911 Building1. 3
FINDINGS
ASBESTOS SUMMARY
During the period from April 26, 2001 through May 15, 2001, PBS Environmental performed an asbestos-containing materials investigation of the 911 Building located at 911 NE 11th Avenue in Portland, Oregon.
Bulk samples of all accessible suspect asbestos-containing materials were collected by an EPA- AHERA accredited inspector and analyzed by an NVLAP certified laboratory using Polarized Light Microscopy (PLM). No destructive investigation was performed during this inspection.
PBS endeavored to locate and sample all accessible suspect asbestos materials. However, hidden or concealed suspect materials may exist. Materials may exist in areas of the building that were not investigated in the scope of this survey. If concealed suspect asbestos materials are discovered during renovation activities that are not identified in this report, destructive sampling should be performed prior to impacting.
The building reportedly underwent a major renovation during the mid-eighties. During the renovation, the majority of asbestos-containing materials were removed. PBS reviewed prior asbestos survey reports and asbestos abatement drawings to aid in completion of this survey.
Sample data from existing surveys that was used to complete this survey is not included in this report.
Floor coating located in the penthouse mechanical rooms and in the east and west stairwell landings tested positive for asbestos. The floor coating is in poor condition in the stairs. It is chipping and flaking from wear. The material is covered with a heavy coat of paint in the mechanical room areas.
Floor tile in various locations in the building tested positive for asbestos. Asbestos-containing floor tile is located in the penthouse microwave equipment room. The mastic in this room tested negative for asbestos; the T/E rooms on each floor under elevated cable floor; and in the break room on the sub-basement Mezzanine under carpet. Remnant, Red 9 inch floor tile presumed to be asbestos-containing was also identified inside the east and west electrical closets on each floor. All floor tile was observed non-friable and in good condition. It is possible that floor tile exists under the elevated cable floors in the office spaces of the building. The interstitial space under the cable floors was not inspected except where the floors were found exposed.
Hard fitting pipe insulation was identified in two remote locations in the building. The hard fittings are located in the freight elevator shaft at the eighth floor level and in a fan room in the basement. The pipe insulation was not sampled, but is presumed to be asbestos-containing.
Black electrical equipment mounting boards located in the elevator equipment room are asbestos-containing. The boards are inside the electrical cabinets, are ¼ to ¾ inch thick and are non-friable.
An asbestos-containing coating was identified on the exterior of the elevator cars. The coating
911 Building1. 4 material is a non-friable, tar-like material applied to the sheet metal as a sound dampener.
Brake pads on the elevator hoists in the penthouse elevator mechanical room tested positive for asbestos. The brake pads are non-friable and brake dust is present on the hoists.
The elevator doors are lined with an asbestos-containing insulation. The door linings are friable and are enclosed inside the steel doors.
Refer to the Asbestos Survey Drawing and Laboratory Data for additional information.
911 Building1. 5
911 BUILDING ASBESTOS SURVEY PHOTO DOCUMENTATION
PBS Project #15273.016
PHOTO 1: ASBESTOS-CONTAINING HARD FITTING ON FIBERGLASS
PIPE INSULATION
PHOTO 2: ASBESTOS-CONTAINING COATING ON CONCRETE IN STAIRWELLS
PHOTO 3: ASBESTOS-CONTAINING VINYL FLOOR TILE IN PENTHOUSE
MICROWAVE EQUIPMENT ROOM
PHOTO 4: ASBESTOS-CONTAINING VINYL FLOOR TILE LOCATED UNDER THE
ELEVATED CABLE FLOOR IN ELECTRICAL T/E ROOMS
PHOTO 5 ASBESTOS-CONTAINING REMNANT FLOOR TILE IN ELECTRICAL CLOSETS
PHOTO 6: ASBESTOS-CONTAINING VINYL FLOOR TILE UNDER CARPET
PHOTO 7: ASBESTOS-CONTAINING ELEVATOR BRAKE PADS ON ELEVATOR HOISTS
PHOTO 8: ASBESTOS CONTAINING ELECTRICAL MOUNTING BOARDS LOCATED
IN THE PENTHOUSE MECHANICAL ROOM
INVENTORY OF ASBESTOS SAMPLES
LEGEND ASBESTOS SAMPLE SYMBOLS
MAY 2001
AS-1
1 OF 1215273.016
ASBESTOS SURVEY
BU
IL
D
IN
G
PO
RT
LA
N D
, O
RE
G O
N
A
SB
E
ST
O S
SU
RV
E Y
P
LA
N
SCALE: 1/16" = 1'-0"
SUB-BASEMENT
ASBESTOS SAMPLE SYMBOLSLEGEND
MAY 2001
AS-2
2 OF 1215273.016
ASBESTOS SURVEY
BU
IL
D
IN
G
PO
RT
LA
N D
, O
RE
G O
N
A
SB
E
ST
O S
SU
RV
E Y
P
LA
N
SCALE: 1" = 40'
BASEMENT
MAY 2001
AS-3
3 OF 1215273.016
ASBESTOS SURVEY
BU
IL
D
IN
G
PO
RT
LA
N D
, O
RE
G O
N
A
SB
E
ST
O S
SU
RV
E Y
P
LA
N
SCALE: 1" = 40'
FIRST FLOOR
MAY 2001
AS-4
4 OF 1215273.016
ASBESTOS SURVEY
BU
IL
D
IN
G
PO
RT
LA
N D
, O
RE
G O
N
A
SB
E
ST
O S
SU
RV
E Y
P
LA
N
SCALE: 1" = 40'
SECOND FLOOR
MAY 2001
AS-5
5 OF 1215273.016
ASBESTOS SURVEY
BU
IL
D
IN
G
PO
RT
LA
N D
, O
RE
G O
N
A
SB
E
ST
O S
SU
RV
E Y
P
LA
N
SCALE: 1" = 40'
THIRD FLOOR
MAY 2001
AS-6
6 OF 1215273.016
ASBESTOS SURVEY
BU
IL
D
IN
G
PO
RT
LA
N D
, O
RE
G O
N
A
SB
E
ST
O S
SU
RV
E Y
P
LA
N
SCALE: 1" = 40'
FOURTH FLOOR
MAY 2001
AS-7
7 OF 1215273.016
ASBESTOS SURVEY
BU
IL
D
IN
G
PO
RT
LA
N D
, O
RE
G O
N
A
SB
E
ST
O S
SU
RV
E Y
P
LA
N
SCALE: 1" = 40'
FIFTH FLOOR
MAY 2001
AS-8
8 OF 1215273.016
ASBESTOS SURVEY
BU
IL
D
IN
G
PO
RT
LA
N D
, O
RE
G O
N
A
SB
E
ST
O S
SU
RV
E Y
P
LA
N
SCALE: 1" = 40'
SIXTH FLOOR
MAY 2001
AS-9
9 OF 1215273.016
ASBESTOS SURVEY
BU
IL
D
IN
G
PO
RT
LA
N D
, O
RE
G O
N
A
SB
E
ST
O S
SU
RV
E Y
P
LA
N
SCALE: 1" = 40'
SEVENTH FLOOR
MAY 2001
AS-10
10 OF 1215273.016
ASBESTOS SURVEY
BU
IL
D
IN
G
PO
RT
LA
N D
, O
RE
G O
N
A
SB
E
ST
O S
SU
RV
E Y
P
LA
N
SCALE: 1" = 40'
EIGHTH FLOOR
LEGEND
MAY 2001
AS-11
11 OF 1215273.016
ASBESTOS SURVEY
BU
IL
D
IN
G
PO
RT
LA
N D
, O
RE
G O
N
A
SB
E
ST
O S
SU
RV
E Y
P
LA
N
SCALE: 1/16" = 1'-0"
911 BUILDING
PENTHOUSE
PENTHOUSE AND
MEZZANINE
LEGEND
MAY 2001
AS-12
12 OF 1215273.016
ASBESTOS SURVEY
BU
IL
D
IN
G
PO
RT
LA
N D
, O
RE
G O
N
A
SB
E
ST
O S
SU
RV
E Y
P
LA
N
SCALE: 1/8" = 1'-0"
911 BUILDING
ELEVATOR CAB
DIAGRAM
BULK SAMPLE INVENTORY
Code Material Location Lab
General Services Administration
8th floor storage; 12" tan with black
NVL Labs, Inc.
15273.016-0001 Vinyl Floor Tile (1) No Asbestos Detected (Brown vinyl tile) Analysis:
8th floor, computer room; 2' x 4' ceiling tile, random fissure, pin perf.
NVL Labs, Inc.
15273.016-0002 Lay-in Ceiling Tile No Asbestos Detected (Grey fibrous material w/paint)
Analysis:
8th floor, west office; 2' x 4' ceiling tile, random fissure, pin perf.
15273.016-0003 Lay-in Ceiling Tile No Asbestos Detected (Grey fibrous material
15273.016-0004 Lay-in Ceiling Tile No Asbestos Detected (Grey fibrous material
15273.016-0005 Lay-in Ceiling Tile No Asbestos Detected (Grey fibrous material
Floor coating in stair well
15273.016-0006 Coating 2% Chrysotile (Gray/tan brittle material) Analysis:
7th floor, west office; 2' x 4' ceiling tile, random fissure, pin perf.
15273.016-0007 Lay-in Ceiling Tile No Asbestos Detected (Grey fibrous material
2.1January 2004 911 Building
PBS Project No: 15273.016
Code Material Location Lab
General Services Administration
7th floor, center office; 2' x 4' ceiling tile, random fissure, pin perf.
NVL Labs, Inc.
15273.016-0008 Lay-in Ceiling Tile No Asbestos Detected (Grey fibrous material
7th floor above ceiling; Troweled-on fireproofing
15273.016-0009 Troweled-on Fireproofing No Asbestos Detected (White brittle material) Analysis:
East stairs; Floor coating in stair well
15273.016-0010 Coating 2% Chrysotile (Tan/gray brittle material) Analysis:
6th floor, library; 2' x 4' ceiling tile, random fissure, pin perf.
15273.016-0011 Lay-in Ceiling Tile No Asbestos Detected (Grey fibrous material
6th floor, west office; 2' x 4' ceiling tile, random fissure, pin perf.
15273.016-0012 Lay-in Ceiling Tile No Asbestos Detected (Grey fibrous material
6th floor, west telephone closet; Troweled-on fireproofing
15273.016-0013 Troweled-on Fireproofing No Asbestos Detected (Tan brittle material
6th floor, west telephone closet; Old plaster above ceiling
15273.016-0014 Wall and Ceiling Plaster No Asbestos Detected (Tan brittle material
2.2January 2004
Code Material Location Lab
General Services Administration
West stairs, 6th floor; Floor coating in stair well
NVL Labs, Inc.
15273.016-0015 Coating 2% Chrysotile (Tan/gray brittle material) Analysis:
5th floor, west office; 2' x 4' ceiling tile, random fissure, pin perf.
15273.016-0016 Lay-in Ceiling Tile No Asbestos Detected (Gray fibrous material
4th floor, west office; 2' x 4' ceiling tile, random fissure, pin perf.
15273.016-0017 Lay-in Ceiling Tile No Asbestos Detected (Gray fibrous material
4th floor, east office; 2' x 4' ceiling tile, random fissure, pin perf.
15273.016-0018 Lay-in Ceiling Tile No Asbestos Detected (Gray fibrous material
West stairs, level 3; Ceiling plaster
15273.016-0019 Wall and Ceiling Plaster No Asbestos Detected (White sandy brittle material)
3rd floor, east office; Debris inside radiator
15273.016-0020 Troweled-on Fireproofing No Asbestos Detected (Tan brittle material) Analysis:
Room 241; 2' x 4' ceiling tile, random fissure, pin perf.
15273.016-0021 Lay-in Ceiling Tile No Asbestos Detected (Gray fibrous material
2.3January 2004
Code Material Location Lab
General Services Administration
1st floor lobby; 2' x 4' ceiling tile, random fissure, pin perf.
NVL Labs, Inc.
15273.016-0022 Lay-in Ceiling Tile No Asbestos Detected (Gray fibrous material
1st floor lobby; 2' x 4' ceiling tile, random fissure, pin perf.
15273.016-0023 Lay-in Ceiling Tile No Asbestos Detected (Gray fibrous material
1st floor corridor, near C.U.; 2' x 4' ceiling tile, randome fissure, pin perf.
15273.016-0024 Lay-in Ceiling Tile No Asbestos Detected (Gray fibrous material
1st floor storage; 2' x 4' ceiling tile, random fissure, pin perf.
15273.016-0025 Lay-in Ceiling Tile No Asbestos Detected (Gray fibrous material
1st floor snack bar; 2' x 4' ceiling tile, random fissure, pin perf.
15273.016-0026 Lay-in Ceiling Tile No Asbestos Detected (Gray fibrous material
Auditorium; 12" white floor tile
15273.016-0027 Vinyl Floor Tile No Asbestos Detected (Off-white vinyl tile) Analysis:
Basement parking; Sprayed-on fireproofing
15273.016-0028 Troweled-on Fireproofing No Asbestos Detected (Tan brittle material
2.4January 2004
Code Material Location Lab
General Services Administration
Basement parking; Sprayed-on fireproofing
NVL Labs, Inc.
15273.016-0029 Troweled-on Fireproofing No Asbestos Detected (Tan brittle material
15273.016-0030 Troweled-on Fireproofing No Asbestos Detected (Tan brittle material
15273.016-0031 Troweled-on Fireproofing No Asbestos Detected (Tan brittle material
15273.016-0032 Troweled-on Fireproofing No Asbestos Detected (Tan brittle material
Basement storage area; Troweled-on fireproofing
15273.016-0033 Troweled-on Fireproofing No Asbestos Detected (White brittle material
15273.016-0034 Troweled-on Fireproofing No Asbestos Detected (White brittle material
15273.016-0035 Troweled-on Fireproofing No Asbestos Detected (White brittle material
2.5January 2004
Code Material Location Lab
General Services Administration
Sub-basement, stairs; Wall plaster
NVL Labs, Inc.
15273.016-0036 Wall and Ceiling Plaster No Asbestos Detected (White sandy brittle material)
SBM, break room; Floor tile under carpet
15273.016-0037 Vinyl Floor Tile 5% Chrysotile (Brown vinyl tile) Analysis:
7% Chrysotile (Black mastic)
Basement mail room; 12" white floor tile
NVL Labs, Inc.
15273.016-0038 Vinyl Floor Tile No Asbestos Detected (White vinyl tile) Analysis:
Basement Boiler Room; Troweled-on fireproofing
15273.016-0039 Troweled-on Fireproofing No Asbestos Detected (White brittle material
15273.016-0040 Troweled-on Fireproofing No Asbestos Detected (White brittle material
15273.016-0041 Troweled-on Fireproofing No Asbestos Detected (White brittle material
15273.016-0042 Troweled-on Fireproofing No Asbestos Detected (White brittle material
2.6January 2004
Code Material Location Lab
General Services Administration
Basement storage area; Remnant ceiling tile mastic dots
NVL Labs, Inc.
15273.016-0043 Mastic No Asbestos Detected (Gray fibrous material) Analysis:
No Asbestos Detected (Brown mastic)
Basement storage area; Remnant ceiling tile mastic dots
NVL Labs, Inc.
15273.016-0044 Mastic No Asbestos Detected (Gray fibrous material) Analysis:
No Asbestos Detected (Brown mastic)
2.7January 2004 911 Building
04/06/200204/06/2001
ASBESTOS INSPECTOR REFRESHER
HAS SUCCESSFULLY COMPLETED THE TRAINING COURSE
Course Date: Expiration Date:
Certificate: IR-01-1084
THIS IS TO CERTIFY THAT
for
Portland, ORCourse Location:
For verification of the authenticity of this certificate contact: PBS Environmental 4412 SW Corbett Avenue, Portland, OR 97239
(503) 248-1939
Dave Stover, Director of Training
RICH A. DUFRESNE
In accordance with TSCA Title II, Part 763, Subpart E, Appendix C of 40 CFR
AHERA is the Asbestos Hazard Emergency Response Act enacting Title II of Toxic Substance Control Act (TSCA)
File details come from the government source that posted it. Updated .