20200803 LBNL SSM-THUP B B48 50pPD Drawings.pdf
PDF 579 KB Posted
- Solicitation number
- GK021120
- Issued by
-
Department of Energy
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Q1
S
N
N
N1
V
V
R
R
R1 R2
25A
BUS
44A
L
44 44 B
25B
16A
6A
10E
42A
5B
2A
45A
13H
48A
5A
Project Number
EDIT THIS FAMILY AND OPEN 'MANAGE IMAGES'
TO REPLACE THIS IMAGE WITH A PROJECT IMAGE
Preliminary Design - 50% 10121250
7/
/2
4:
:1
P
M B
IM
_L B
N L
S S
M
T H
U P
-A
-C E
N T
R A
L
LB
N
L S
S M
-T H
U P
.r vt
HDR Architecture 201 California St
San Francisco, CA 94111
GHD
Civil Enginner | Landscape Architect
655 Montgomery Street, Suite 1010 San Francisco, CA 95111 t 415.283.4970
Smith, Fause & McDonald Inc
IT/ AV/ Acoustics Consultants
Rutherford + Chekene
Structural Engineer
The Marshall Associates
Food Service Consultant
UNIVERSITY OF
CALIFORNIA
LAWRENCE
BERKELEY
NATIONAL
LABORATORY
1 CYCLOTRON ROAD
BERKELEY, CALFORNIA 94720
Building 54 1 Cyclotron Rd
Berkeley, CA 94720
351 8th Street San Franscisco, CA 94103 t 415.255.9140 f 415.255.9180
375 Beale Street, Suite 310 San Francisco, CA 94105 t 415.568.4400 f 415.618.0684
1929 Parkmont Drive Alamo, CA 94507 t 415.677.1200
P re li m in a ry
D e s ig n
/0
3/
08/03/2020
VICINITY MAP PROJECT INFORMATION
SHEET INDEX - BUILDING 48
Sheet Number Sheet Name Sheet Issue Date
01-GENERAL
G-048 COVER 08/03/2020
07-STRUCTURAL
S-700 STRUCTURAL GENERAL & NOTES 08/03/2020
S-701 FOUNDATION & 1ST FLOOR PLAN AND DETAILS 08/03/2020
S-702 2ND FLOOR PLAN AND DETAILS 08/03/2020
S-703 ROOF PLAN AND DETAILS 08/03/2020
08-ARCHITECTURAL
A-701 BLDG. 48 SEISMIC UPGRADE ARCHITECTURAL
DETAILS
08/03/2020
LBNL SSM B - BUILDING
48 SEISMIC UPGRADE
SCOPE OF WORK:
Building 48, circa 1980, is used as residential quarters for the adjacent Fire Station Building. The two story structure is composed of a wood 2x joist and glu-laminated beam roof and floor framing system that is supported on perimeter reinforced CMU walls, interior wood framed bearing walls, and steel columns. A one-story addition composed of concrete fill over metal deck supported by structural steel beams and columns extended the building to the north and west in 1992.
Square footage is approximately 6,500. A partial seismic upgrade, consisting of installing new wall to floor anchors at the second level, was completed in 2005.
An ASCE 41-13 seismic evaluation of B48 Firehouse building has been performed in accordance with the University of California Seismic Safety Policy for existing buildings. The building is designated as an essential facility, or Risk Category IV per the 2016 California Building Code (CBC). The evaluation identifies the seismic deficiencies that must be mitigated to achieve the Expected Seismic Performance Level II in accordance with the UC Seismic Safety Policy, Appendix A, Expected Seismic Performance Levels. The evaluation methodology consists of a Tier-1 screening and a Tier-2 deficiency-based evaluation using the linear static procedure for two performance levels under the prescribed ground motions required by the University Seismic Safety Policy. Please refer to Appendix C for the complete evaluation report.
The seismic evaluation identified the following seismic deficiencies that must be mitigated to achieve the Level II rating:
• Roof framing to CMU wall anchorage. Retrofit details developed in the LBNL 2005 seismic modifications may be assumed for cost estimation purposes.
• Saw-cut openings in original CMU walls that lack trim reinforcement. Retrofit details developed in the LBNL 2005 seismic modifications may be assumed for cost estimation purposes.
• Lack of lateral load resisting element at Lobby structure. Retrofit detail consists of the installation of a braced frame or plywood shearwall lateral load resisting element.
COORDINATION OF DOCUMENTS.
DIMENSIONAL CONTROL.
STRUCTURAL TESTING AND INSPECTION.
GENERAL
HAZARDOUS MATERIALS
DRILLED DOWELS
DESIGN CRITERIA
ABBREVIATIONS
DRAWING SYMBOLS:
DETAIL NUMBERING:
CAST-IN-PLACE CONCRETE
STRUCTURAL STEEL FRAMING NOTES
STEEL
TIMBER
12 9 6 3
11 8 5 2
10 7 4 1
(MAY BE USED WITH OR WITHOUT PERIOD)
SQ. SQUARE
STD. STANDARD
STL. STEEL
SUSP. SUSPENDED
SYM. SYMMETRICAL
T.O.C. TOP OF CONCRETE
T.O.W. TOP OF WALL
THK. THICK
TYP. TYPICAL
U.O.N. UNLESS OTHERWISE NOTED
V.I.F. VERIFY IN FIELD
VERT. VERTICAL
W.P. WORK POINT
W/ WITH
W/O WITHOUT
WA. WEDGE ANCHOR
WP. WATERPROOFING
WT. WEIGHT
& AND
(E) EXISTING
(N) NEW
@ AT
# POUND OR NUMBER
DIAMETER OR ROUND
A.B. ANCHOR BOLT
ADD'L ADDITIONAL
ADJ. ADJACENT
APPROX. APPROXIMATE
ARCH. ARCHITECTURAL
B.O.F. BOTTOM OF FOOTING
BLDG. BUILDING
BM BEAM
BOT. BOTTOM
BTWN. BETWEEN
C.I.P. CAST-IN-PLACE
C.J. CONSTRUCTION JOINT
CL CENTERLINE
CLG. CEILING
CLR. CLEAR
COL. COLUMN
CONC. CONCRETE
CONN. CONNECTION
CONSTR. CONSTRUCTION
CONT. CONTINUOUS
CTR. CENTER
DBL. DOUBLE
DET. DETAIL
DIA. DIAMETER
DIM. DIMENSION
DN. DOWN
DO. DITTO
DWG. DRAWING
E.F. EACH FACE
E.S. EACH SIDE
E.W. EACH WAY
EA. EACH
EL. ELEVATION
ELEC. ELECTRICAL
EMBED. EMBEDMENT
EQ. EQUAL
EQPT. EQUIPMENT
EXT. EXTERIOR
F.O.S. FACE OF STUD
F.O.W. FACE OF WALL
F.S. FAR SIDE
FDN. FOUNDATION
FIN. FINISH
FL. FLOOR
FT. FOOT OR FEET
FTG. FOOTING
FUT. FUTURE
G.B. GRADE BEAM
GA. GAUGE
GALV. GALVANIZED
GR. GRADE
H.S.B. HIGH STRENGTH BOLT
H.S.S. HOLLOW STRUCTURAL SECTION
HGR. HANGER
HK. HOOK
HORIZ. HORIZONTAL
HT. HEIGHT
I.F. INSIDE FACE
INT. INTERIOR
JT. JOINT
LB. POUND
M.B. MACHINE BOLT
MAX. MAXIMUM
MECH. MECHANICAL
MFR. MANUFACTURER
MIN. MINIMUM
MISC. MISCELLANEOUS
N. NORTH
N.F. NEAR FACE
N.I.C. NOT IN CONTRACT
N.S. NEAR SIDE
N.T.S. NOT TO SCALE
NO. NUMBER
O.C. ON CENTER
OH. OPPOSITE HAND
OPNG. OPENING
OPP. OPPOSITE
P.S.F. POUNDS PER SQUARE FOOT
P.S.I. POUNDS PER SQUARE INCH
PT. POINT
PTN. PARTITION
R.O. ROUGH OPENING
RAD. RADIUS
REFE. REFERENCE
REINF. REINFORCING
REQ. REQUIRED
S.A.D. SEE ARCH. DRAWINGS
S.C.D. SEE CIVIL DRAWINGS
S.M.D. SEE MECH. DRAWINGS
S.O.G. SLAB ON GRADE
S.S. STAINLESS STEEL
SCHED. SCHEDULE
SECT. SECTION
SHT. SHEET
SIM. SIMILAR
SPEC. SPECIFICATION
Ø
(E) EXISTING
(N) NEW
PEN. PENETRATION
S301A
S201A
ADDITIONAL SAMPLING AND TESTING WILL BE REQUIRED WHERE MATERIALS CANNOT BE POSITIVELY
TRACED TO MILL CERTIFICATES.
E. MATERIAL TESTING: THE ITEMS INDICATED BELOW REQUIRE SAMPLING AND/ OR
TESTING IN ACCORDANCE WITH PROVISIONS OF THE CBC AND REQUIREMENTS
OF THE PROJECT SPECIFICATIONS.
A. THE FOLLOWING CHECKLISTS ARE TO ASSIST THE CONTRACTOR IN
SCHEDULING OF TESTING AND INSPECTION RELATED TO STRUCTURAL
FEATURES. THE WORK OF OTHER DISCIPLINES MAY REQUIRE TESTING AND
INSPECTION THAT IS ADDITIONAL TO THE ITEMS LISTED BELOW.
B. REFER TO APPLICABLE PROVISIONS OF DIVISION 1 OF THE PROJECT
SPECIFICATIONS AND THE GENERAL CONDITIONS OF THE CONTRACT FOR SLAC
REPRESENTATIVE, SLAC TESTING LABORATORY, GEOTECHNICAL ENGINEER AND
CONTRACTOR'S RESPONSIBILITIES REGARDING TESTING AND INSPECTION.
C. REFER TO PROJECT SPECIFICATIONS FOR MORE DETAILED REQUIREMENTS FOR
TESTS AND INSPECTIONS. THE PROJECT SPECIFICATIONS SHALL TAKE
PRECEDENCE OVER THESE CHECKLISTS.
D. SPECIAL INSPECTORS SHALL BE QUALIFIED BY TRAINING AND EXPERIENCE FOR
THE REQUIRED INSPECTIONS AND MUST BE ACCEPTABLE TO THE SLAC REPRESENTATIVE.
INSPECTORS SHALL THOROUGHLY REVIEW THE APPLICABLE PORTIONS OF THE DOCUMENTS.
INSPECTORS SHALL PERFORM ALL DUTIES AND RESPONSIBILITIES AS REQUIRED BY CBC
SECTION 1701.
CONCRETE
ITEM
MATERIAL TESTING CHECKLIST
RUTHERFORD & CHEKENE ASSUMES NO RESPONSIBILITY FOR THE MANAGEMENT OF HAZARDOUS
MATERIALS THAT MAY BE ON THE SITE.
A. RUTHERFORD & CHEKENE HAS NOT PERFORMED INVESTIGATIONS TO DETERMINE THE
PRESENCE OF HAZARDOUS MATERIALS. SLAC WILL PROVIDE THE RESULTS OF SUCH
INVESTIGATIONS THAT HAVE BEEN PERFORMED.
B. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING THAT PERSONNEL WITHIN THE
WORK AREA ARE PROTECTED FROM EXPOSURE TO HAZARDOUS MATERIALS. IF HAZARDOUS
MATERIALS ARE DISCOVERED, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE
SLAC'S REPRESENTATIVE AND CEASE WORK UNTIL CONDITIONS CAN BE MAINTAINED IN
COMPLIANCE WITH ALL APPLICABLE REGULATIONS.
A. DO NOT USE SCALED DIMENSIONS. WHERE NO WRITTEN DIMENSION IS PROVIDED, CONSULT WITH THE SLAC
REPRESENTATIVE FOR CLARIFICATION BEFORE PROCEEDING WITH THE WORK.
B. DIMENSION POINTS ARE AS FOLLOWS, UNLESS OTHERWISE INDICATED:
1. TYPICAL, U.O.N.: CENTERLINE.
2. WALLS: FACE OF STUD OR FACE OF CONCRETE.
3. STEEL ANGLES AND CHANNELS: FACE.
C. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONAL CONTROL FOR THE FOLLOWING STRUCTURAL
FEATURES, UNLESS DIMENSIONS ARE NOTED ON THE STRUCTURAL DRAWINGS:
1. DOOR AND WINDOW OPENINGS.
2. LOCATION AND SIZE OF CURBS AND PADS.
A. REFER TO ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR LOCATIONS
AND SIZES OF THE FOLLOWING ITEMS:
1.
GROUTED DOWELS IN CONCRETE
SLUMP, STRENGTH, TEMP., AIR
PULL TESTS
NOTES
A. WIND DESIGN PARAMETERS:
1. ULTIMATE DESIGN WIND SPEED: 110 MPH
2. EXPOSURE: C
3. IMPORTANCE FACTOR: 1.5
B. SEISMIC DESIGN:
FINISH ELEVATION DESIGNATION OF TOP OF STRUCTURAL
CONCRETE. SEE PLANS FOR ELEVATION ASSOCIATED
WITH DESIGNATION, TYPICAL, U.O.N.
LEVEL 1
T.O.C.
GRIDLINE
ELEVATION
SECTION NUMBER ON WHICH DETAIL IS FOUND
SHEET ON WHICH DETAIL IS FOUND
A. THE SYMBOLS ON PLANS TO INDICATE SECTIONS, ELEVATIONS, AND DETAILS ARE AS FOLLOWS:
SIM.
1.
2.
B. SEE LEGEND ON PLAN SHEETS FOR ADDITIONAL SYMBOLS.
SPECIFICATIONS
SECTION (S)
SPECIAL INSPECTION CHECKLIST
ITEM NOTES
CAST-IN-PLACE CONCRETE
GROUTED DOWELS IN CONCRETE
MIX DESIGN
PER ICC REPORT
SPECIFICATIONS
SECTION (S)
03 30 00
03 61 00
03 61 00
03 30 00
F. THE STRUCTURAL ENGINEER WILL MAKE PERIODIC VISITS TO THE SITE TO CONFIRM THAT THE
CONSTRUCTION IS IN GENERAL CONFORMANCE WITH THE CONTRACT DOCUMENTS.
WHERE MORE THAN ONE BLOCK IS USED FOR A SINGLE DETAIL, THE
NUMBER OF THE LOWER LEFT CORNER IS USED; THUS NUMBERS ARE
ALWAYS IN THE SAME LOCATION ON THE SHEET.
3. FACE OF WALL DIMENSIONS.
4. ELEVATION OF CEILING.
A. EPOXY ADHESIVE: PROVIDE ONE OF THE FOLLOWING, OR EQUAL.
1. HIT RE 500-V3 ADHESIVE ANCHORING SYSTEM, HILTI, INC. (ICC ESR-2322).
2. SET-XP EPOXY ADHESIVE, SIMPSON STRONG-TIE CO.
A. REINFORCING STEEL
1. ALL BARS, U.O.N.: ASTM A615, GR 60, U.O.N., DEFORMED.
2. ALL BARS TO BE WELDED ASTM A706.
C.
CONCRETE MIXES: SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
USE MIN.
STRENGTH
WEIGHT
SLAB-ON-GRADE, WALL INFILL, PADS, AND CURBS. 4,000 PSI NORMAL WEIGHT
NON-SHRINK GROUT: PROVIDE ONE OF THE FOLLOWING, OR EQUAL.
1. EUCO N.S., EUCLID CHEMICAL CO.
2. MASTERFLOW 928, MASTER BUILDERS
3. FIVE STAR GROUT, US GROUT CORP.
B.
A. FOR MORE DETAILED INFORMATION, SEE PROJECT SPECIFICATIONS. THE SPECIFICATIONS SHALL
TAKE PRECEDENCE OVER THESE
NOTES.
B. ALL CONSTRUCTION SHALL CONFORM TO THE CALIFORNIA BUILDING CODE (CBC), TITLE 24, 2019
EDITION.
C. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS FOR EXISTING AS WELL AS
NEW CONSTRUCTION AT THE JOB SITE BEFORE COMMENCING WORK AND SHALL REPORT ANY
DISCREPANCIES TO THE OWNER'S
REPRESENTATIVE.
D. OMISSIONS OR CONFLICTS BETWEEN VARIOUS ELEMENTS OF THE DRAWINGS, NOTES, AND
DETAILS SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE AND
RESOLVED BEFORE PROCEEDING WITH THE
WORK.
E. DETAILS SHOWN SHALL BE INCORPORATED INTO THE PROJECT AT ALL APPROPRIATE LOCATIONS
WHETHER SPECIFICALLY CALLED OUT OR
NOT.
F. THE CONTRACTOR MUST SUBMIT IN WRITING ANY REQUESTS FOR MODIFICATIONS TO THE PLANS
AND SPECIFICATIONS. SHOP DRAWINGS SUBMITTED TO THE OWNER'S REPRESENTATIVE FOR
REVIEW DO NOT CONSTITUTE "IN WRITING" UNLESS IT IS CLEARLY NOTED THAT SPECIFIC
CHANGES ARE BEING
REQUESTED.
G. UNLESS SPECIFICALLY SHOWN ON THESE PLANS, NO STRUCTURAL MEMBER SHALL BE CUT,
DRILLED, OR NOTCHED WITHOUT PRIOR WRITTEN AUTHORIZATION FROM THE OWNER'S
REPRESENTATIVE.
A. CODE: COMPLY WITH ANSI / AISC 360 "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS", 2010, FOR ALL
TOLERANCES, SPACINGS, MINIMUM WELD SIZES AND OTHER DETAILS NOT NOTED OR SHOWN.
A. W-SHAPES: ASTM A992.
B. ANGLES, CHANNELS, BENT PLATES, SOLID RODS AND FLAT BARS: ASTM A36, U.O.N.
C. PLATE: ASTM A572, GRADE 50 TYPICAL; ASTM A36 WHERE NOTED.
D. ROUND, SQUARE, AND RECTANGULAR TUBES: ASTM A500, GRADE B.
E. PIPES: ASTM A53, TYPE E, GRADE B, TYP. U.O.N. ASTM A53, TYPE S, GRADE B FOR AESS SHAPES.
F. HIGH STRENGTH BOLTS: ASTM A325, U.O.N. BOLTS ARE INSTALLED AS PRETENSIONED, U.O.N.
IF CONTRACTOR CHOOSES TO USE TWIST-OFF TENSION-CONTROL TYPE BOLTS, ASTM F1852 MAY BE
SUBSTITUTED FOR ASTM A325.
G. MACHINE BOLTS AND THRU-BOLTS: ASTM A307.
H. WELDING :
1. ELECTRODES: E70XX
EXPANSION ANCHOR INSTALLATION PER ICC REPORTVARIOUS
STRUCTURAL STEEL WELDING CONTINUOUS05 12 00
PERIODIC05 12 00STRUCTURAL STEEL WELDING, SINGLE
PASS FILLET NOT EXCEEDING 5/16"
PLACEMENT ANCHOR BOLTS, & EMBED 03 10 00, 03 20 00, 03 30 00, 05 12 00 -
EXPANSION ANCHORS TORQUE OR PULL TESTVARIOUS
GROUT COMPRESSIVE STRENGTH03 30 00
STRUCTURAL WELDING COMPLETE JOINT PEN. UT05 12 00
OTHER STRUCTURAL WELDING MT05 12 00
1. SEISMIC COEFFICIENTS PER ASCE 41-13 FOR SITE COORDINATES 37.876° N, 122.249° W:
BSE-1E (20/50) : SDS = 1.293, SD1 = 0.719
BSE-2E (5/50) : SDS = 2.450, SD1 = 1.389
BSE-1N (10/50) : SDS = 1.646, SD1 = 1.026
BSE-2N (2/50) : SDS = 2.468, SD1 = 1.539
2. SITE CLASS D.
3. RISK CATEGORY IV.
4. IMPORTANCE FACTOR I = 1.5
5. SEISMIC DESIGN CATEGORY E.
C. ENGINEERED LUMBER : SEE SPECIFICATION.
A. JOISTS, PLATES, BLOCKING, STUDS AND SILLS SHALL BE 19% MAXIMUM
MOISTURE CONTENT PRIOR TO SURFACING. U.O.N.
B. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS INCLUDING MOISTURE CONTENT.
WHERE (N) LUMBER IS IN CONTACT WITH (E) LUMBER, THE (N) LUMBER
SHALL BE 15% MAXIMUM MOISTURE CONTACT FOR SHRINKAGE COMPATIBILITY.
(PROGRESS, ESTIMATE, BID, CONSTRUCTION,
CONFORMED, REVISION, RECORD)(IF REVISION, APPLIES ONLY TO REVISED WORK)
ISSUEPROFESSIONAL SEAL
PROJECT NO. 10221250
DRAWING NO.
SHEET
DATE
SCALE
APPROVED BY
CHECKED BY
DRAWN BY
REMARKSDATE
BY
APPR'D
BY
CHECKED
BY
DRAWN
NUMBER
REVISIONCONSULTING A/E FIRMCONSULTING FIRMCONSULTING FIRM
50%
FACILITIES DIVISION
LBNL SSM 3B- BUILDING 48 SEISMIC UPGRADE
Preliminary
Design
Pre lim ina ry Des ign
50% 12" = 1'-0"
UNIVERSITY OF CALIFORNIA
LAWRENCE BERKELEY NATIONAL LABORATORY
STRUCTURAL GENERAL & NOTES
S-70008/03/2020
JRT 08/03/2020
1 5
B.5
F
(E) 5" SLAB-ON-GRADE
24"
(E) 4"Ø PIPE
20"
24"
6'
B
A
C
D
E
4'
1"
4'
2 2.3 3 4 6 7 8 9
12' - 6" 3' - 7" 5' - 11" 9' - 3" 9' - 3" 9' - 6" 10' - 6" 10' - 6" 10' - 6"
(E ) 1
2" F
T G
(E) W5X16 COL
B R
A C
E D
F R
A M
IN
G
C U
R B
, T Y
P
1/
2" W
ID
E
C O
N C
F T
G
T Y
P
1'
C O
N T
(E) 4" CONC. SLAB, 2" SAND,
VAPOR BARRIER & 4"
GRAVEL W/ #4 @ 12" O.C.
E.W. @ MID-DEPTH
BRACED FRAME
CURB
7 1/2" CONC.
FTG, TYP.
1' - 6" CONT.
(N) C8X11.5 EPOXY BOLTED TO (E) CMU.
INSTALL ONE SIDE OF OPENING AS
SHOWN AND OVER TOP OF OPENING,
EXTEND 2'-0" BEYOND JAMB EA SIDE.
(N) C8X11.5 EPOXY BOLTED TO (E)
CMU. INSTALL EA JAMB AND OVER
TOP OF OPENING, EXTEND 2'-0"
BEYOND JAMB EA SIDE.
(E) HSS COL
(N) HSS BRACE
BTWN (E)
COLUMNS
SHEET NOTES:
DRAWING DEPICT THE SEISMIC UPGRADE MEASURES NECESSARY TO
ACHIEVE THE EXPECTED SEISMIC PERFORMANCE LEVEL II IN
ACCORDANCE WITH THE UC SEISMIC SAFETY POLICY, APPENDIX A.
THE BUILDING IS DESIGNATED AS AN ESSENTIAL FACILITY, OR RISK
CATEGORY IV.
RETROFIT SCOPE:
1. INSTALL NEW HSS BRACE LEVEL 1 TO LEVEL 2 AT (E) STAIR ON
LINE 2, STRENGTHEN (E) COLUMNS AS REQ'D.
2. INSTALL PERIMETER CHANNEL AROUND EXISTING OPENINGS IN
CMU WALL, TWO (2) LOCATIONS LINE B.5.
3. INSTALL ANCHORAGE FROM CMU EXTERIOR WALLS TO (E) ROOF
FRAMING ON ROOF PERIMENTER PER S-703.
LEGEND:
Q1
S
N
N
N1
V
V
R
R
R1 R2
25A
BUS
44A
L
44 44 B
25B
16A
6A
10E
42A
5B
2A
45A
13H
48A
5A
(PROGRESS, ESTIMATE, BID, CONSTRUCTION,
CONFORMED, REVISION, RECORD)(IF REVISION, APPLIES ONLY TO REVISED WORK)
ISSUEPROFESSIONAL SEAL
PROJECT NO. 10221250
DRAWING NO.
SHEET
DATE
SCALE
APPROVED BY
CHECKED BY
DRAWN BY
REMARKSDATE
BY
APPR'D
BY
CHECKED
BY
DRAWN
NUMBER
REVISIONCONSULTING A/E FIRMCONSULTING FIRMCONSULTING FIRM
50%
FACILITIES DIVISION
LBNL SSM 3B- BUILDING 48 SEISMIC UPGRADE
Preliminary
Design
Pre lim ina ry Des ign
50%
BUILDING KEYPLAN
2' 4' 8'
1/4" = 1'-0"
UNIVERSITY OF CALIFORNIA
LAWRENCE BERKELEY NATIONAL LABORATORY
FOUNDATION & 1ST FLOOR PLANS AND DETAILS
S-70108/03/2020
JRT 08/03/2020
1/4" = 1'-0" 1
BUILDING 48 - FOUNDATION & 1ST FLOOR
FRAMING PLAN
(E) 2x12 @ 16" O.C.
(E) 2x12 @ 16" O.C.
(E) 2x12 @ 16" O.C.
(E) 2x12 @ 16" O.C.
(E) 5/8" PLYWOOD
(E
3/
4" x2
1" G
.L
(E) 2x12 @ 16" O.C.
(E) 6x12 S.S.(E) 3x12(E) 6x12 S.S.(E) 3x12
(E) 2x6 @ 16" O.C.
(E) 2x12 @ 16" O.C.
(E) 2x12 @ 16" O.C.
(E) 3x12x16'-9"±(E) 3x12x17'-4"±
(E) 2x12 @ 16" O.C.
(E) 3x10 @ 16" O.C.
(E) W8X13 (E) W8X13 (E) W8X13 (E) W8X13 (E) W8X13 (E) W8X13 (E) W8X13 (E) W8X13
(E
W 8X
(E
C 8X
.5
F
LA
T
(E
C 5X
6.
(F
LA
T
(E
C 5X
6.
(F
LA
T
(E
C 5X
6.
(F
LA
T
(E
C 5X
6.
(F
LA
T
(E
C 8X
.5
F
LA
T
(E
C 5X
6.
(F
LA
T
(E
C 5X
6.
(F
LA
T
(E
W 8X
(E) C5X6.7 (FLAT)
(E) W8X18
(E
W 8X
(E) W8X28
(E) TS4x4x1/4 COL ATOP
W5X16 BELOW
(E) W8X28 & TS3 1/2x2 1/2x3/16 (E) W8X28 & TS3 1/2x2 1/2x3/16(E
C 5X
6.
(F
LA
T
(E
C
X
.7
(E
C
X
.7
(E
W 8X
(E) W8X13(E) W8X13
(E
W 8X
W8X13 ONE PC & TS4X2X3/16
(E
C 3X
4.
C O
N T
. S
LO
P
IN
G L
E D
G E
R L
4X 3X
1/
(E
W 4X
O N
E P
C
(E) C4X5.4
(E
C 4X
5.
LE
D
G E
R
(E) 2x12
(E) 2x12
(E) 3X LEDGER
(E) 2x12
(E) 2x12
(E) 2x12
(E) 2x12
(E) HD5A W/ 3/4"Ø
ADHESIVE ANCHORS
@ (E) CMU WALL
(E) 3X12 LEDGER
3 1/4" LT. WT. CONC.
OVER 3" QL-99-16 MTL.
DKG. T.O.S. EL.=S.A.D.
1 5
B.5
F
B
A
C
D
E
4'
1"
4'
2 2.3 3 4 6 7 8 9
12' - 6" 3' - 7" 5' - 11" 9' - 3" 9' - 3" 9' - 6" 10' - 6" 10' - 6" 10' - 6"
C8X11.5 OVER
(E) OPNG BELOW
(N) HSS BRACE
BELOW BTWN
(E) COLUMNS
SHEET NOTES:
DRAWING DEPICT THE SEISMIC UPGRADE MEASURES NECESSARY TO
ACHIEVE THE EXPECTED SEISMIC PERFORMANCE LEVEL II IN
ACCORDANCE WITH THE UC SEISMIC SAFETY POLICY, APPENDIX A.
THE BUILDING IS DESIGNATED AS AN ESSENTIAL FACILITY, OR RISK
CATEGORY IV.
RETROFIT SCOPE:
1. INSTALL NEW HSS BRACE LEVEL 1 TO LEVEL 2 AT (E) STAIR ON
LINE 2, STRENGTHEN (E) COLUMNS AS REQ'D.
2. INSTALL PERIMETER CHANNEL AROUND EXISTING OPENINGS IN
CMU WALL, TWO (2) LOCATIONS LINE B.5.
3. INSTALL ANCHORAGE FROM CMU EXTERIOR WALLS TO (E) ROOF
FRAMING ON ROOF PERIMENTER PER S-703.
LEGEND:
Q1
S
N
N
N1
V
V
R
R
R1 R2
25A
BUS
44A
L
44 44 B
25B
16A
6A
10E
42A
5B
2A
45A
13H
48A
5A
(PROGRESS, ESTIMATE, BID, CONSTRUCTION,
CONFORMED, REVISION, RECORD)(IF REVISION, APPLIES ONLY TO REVISED WORK)
ISSUEPROFESSIONAL SEAL
PROJECT NO. 10221250
DRAWING NO.
SHEET
DATE
SCALE
APPROVED BY
CHECKED BY
DRAWN BY
REMARKSDATE
BY
APPR'D
BY
CHECKED
BY
DRAWN
NUMBER
REVISIONCONSULTING A/E FIRMCONSULTING FIRMCONSULTING FIRM
50%
FACILITIES DIVISION
LBNL SSM 3B- BUILDING 48 SEISMIC UPGRADE
Preliminary
Design
Pre lim ina ry Des ign
50%
BUILDING KEYPLAN
2' 4' 8'
1/4" = 1'-0"
UNIVERSITY OF CALIFORNIA
LAWRENCE BERKELEY NATIONAL LABORATORY
2ND FLOOR PLAN AND DETAILS
S-70208/03/2020
JRT 08/03/2020
1/4" = 1'-0" 1
BUILDING 48 - 2ND FLOOR FRAMING PLAN
4' - 4" 4' - 4"
(E) 3x12 @ 4'-0" AT PLYWOOD JOINTS
(E) 2x12 @ 16" IN BETWEEN
(E) 1/2" PLYWOOD SHEATHING,
STAGGERED JOINTS. NAILING -
SEE GENERAL NOTES SHEET S-1
(E) 5 1/8"x13 1/2" G.L.
(E) 2x12 @ 16" O.C. IN BETWEEN 3x12'S @ 4'-0" O.C.
(E) 6x12
B.5
F
C
D
E
4'
1"
4 6 7 8 9
9' - 3" 9' - 6" 10' - 6" 10' - 6" 10' - 6"
(N) L 4X6 ANGLE @ 48" OC TO(E) 3X12.
EPOXY BOLT TO (E) CMU. PROVIDE THRU
BOLT STO (E) 3X. TYPICAL LINE B.5 AND F
PROVIDE (N) 3X12 BLKG FOR 4 JOIST
BAYS, PROVIDE L6X3 ANGLE
CONNECTION BLKG TO BLKG EA SIDE
OF (E) JOIST W/ THRU BOLT TO BLKG
AND THRU BOLT ANGLE TO ANGLE
THROUGH (E) JOIST. TYP AT EA DBL
ANGLE LINE 3.8 AND 9
(N) L 4X6 ANGLE @ 48" EA SIDE OF (N)
3 X BLKG. EPOXY BOLT TO (E) CMU
WALL. AND THRU BOLT TO (N) BLKG
(N) A35 CLIPS BLKG TO (E) PLYWD W/
WOOD SCREWS. INSTALL FROM
UNDERSIDE.
SHEET NOTES:
DRAWING DEPICT THE SEISMIC UPGRADE MEASURES NECESSARY TO
ACHIEVE THE EXPECTED SEISMIC PERFORMANCE LEVEL II IN
ACCORDANCE WITH THE UC SEISMIC SAFETY POLICY, APPENDIX A.
THE BUILDING IS DESIGNATED AS AN ESSENTIAL FACILITY, OR RISK
CATEGORY IV.
RETROFIT SCOPE:
1. INSTALL NEW HSS BRACE LEVEL 1 TO LEVEL 2 AT (E) STAIR ON
LINE 2, STRENGTHEN (E) COLUMNS AS REQ'D.
2. INSTALL PERIMETER CHANNEL AROUND EXISTING OPENINGS IN
CMU WALL, TWO (2) LOCATIONS LINE B.5.
3. INSTALL ANCHORAGE FROM CMU EXTERIOR WALLS TO (E) ROOF
FRAMING ON ROOF PERIMENTER PER S-703.
LEGEND:
Q1
S
N
N
N1
V
V
R
R
R1 R2
25A
BUS
44A
L
44 44 B
25B
16A
6A
10E
42A
5B
2A
45A
13H
48A
5A
(PROGRESS, ESTIMATE, BID, CONSTRUCTION,
CONFORMED, REVISION, RECORD)(IF REVISION, APPLIES ONLY TO REVISED WORK)
ISSUEPROFESSIONAL SEAL
PROJECT NO. 10221250
DRAWING NO.
SHEET
DATE
SCALE
APPROVED BY
CHECKED BY
DRAWN BY
REMARKSDATE
BY
APPR'D
BY
CHECKED
BY
DRAWN
NUMBER
REVISIONCONSULTING A/E FIRMCONSULTING FIRMCONSULTING FIRM
50%
FACILITIES DIVISION
LBNL SSM 3B- BUILDING 48 SEISMIC UPGRADE
Preliminary
Design
Pre lim ina ry Des ign
50%
BUILDING KEYPLAN
2' 4' 8'
1/4" = 1'-0"
UNIVERSITY OF CALIFORNIA
LAWRENCE BERKELEY NATIONAL LABORATORY
ROOF PLAN AND DETAILS
S-70308/03/2020
JRT 08/03/2020
1/4" = 1'-0" 1
BUILDING 48 - ROOF FRAMING PLAN
299WLAREA
202 204 206
205 207
197 196
118A119 118B
104 106
105A
118D 117 116 115
LOBBY
AREA ON
FIRST
FLOOR
TO
BLDG
45 & 43
OPEN
TO
FLOOR
BELOW
ROOFTOP 48-1
BLDG 45
Q1
S
N
N
N1
V
V
R
R
R1 R2
25A
BUS
44A
L
44 44 B
25B
16A
6A
10E
42A
5B
2A
45A
13H
48A
5A
(PROGRESS, ESTIMATE, BID, CONSTRUCTION,
CONFORMED, REVISION, RECORD)(IF REVISION, APPLIES ONLY TO REVISED WORK)
ISSUEPROFESSIONAL SEAL
PROJECT NO. 10221250
DRAWING NO.
SHEET
DATE
SCALE
APPROVED BY
CHECKED BY
DRAWN BY
REMARKSDATE
BY
APPR'D
BY
CHECKED
BY
DRAWN
NUMBER
REVISIONCONSULTING A/E FIRMCONSULTING FIRMCONSULTING FIRM
50%
FACILITIES DIVISION
LBNL SSM B- BUILDING 48 SEISMIC UPGRADE
Preliminary
Design
Pre lim ina ry Des ign
50%
BUILDING KEYPLAN
4' 8' 16'
1/8" = 1'-0"
UNIVERSITY OF CALIFORNIA
LAWRENCE BERKELEY NATIONAL LABORATORY
BLDG. 48 SEISMIC UPGRADE ARCHITECTURAL DETAILS
A-70108/03/2020
HDR Architecture 201 California St San Francisco, CA 94111
OP 08/03/2020
1/8" = 1'-0" 1
BUILDING 48 - EXISTING CONDITIONS SECOND FLOOR PLAN
1/8" = 1'-0" 2
BUILDING 48 - EXISTING CONDITIONS FIRST FLOOR PLAN
| 01 - GENERAL |
| COVER |
| 07 - STRUCTURAL |
| S-700 - STRUCTURAL GENERAL & NOTES |
| S-701 - FOUNDATION & 1ST FLOOR PLANS AND DETAILS |
| S-702 - 2ND FLOOR PLAN AND DETAILS |
| S-703 - ROOF PLAN AND DETAILS |
| 08 - ARCHITECTURAL |
| A-701 - BLDG. 48 SEISMIC UPGRADE ARCHITECTURAL DETAILS |
File details come from the government source that posted it. Updated .