TechnicalOrder_Inspection_Requirements_5_20_24.pdf

PDF 484 KB Posted

Attached to
FA853424R0003 AMENDMENT 4 Air Transportable Galley and Lavatory (ATGL) RFP
Solicitation number
FA853424R0003
Issued by

About this file

This document is a technical order detailing the inspection requirements for the Air Transportable Galley/Lavatory (ATGL) unit. It covers periodic, preflight, postflight, and depot-level inspections, including requirements for the galley, lavatory, sides, top, and bottom areas of the ATGL. Inspections check for issues such as cracks, corrosion, loose hardware, security of components, and cleanliness. Detailed step-by-step procedures are provided for each inspection item. The document also includes post-inspection steps for re-installing components and performing operational checkout. This technical order supports the RFP for sustainment of the ATGL, which includes program engineering support, overhaul, repair, and material management.

View the file

Other files

File Type Posted
FA853424R0003_0004.pdf PDF
ATGL PWS 1 JULY 2024.pdf PDF
FA853424R0003_0003.pdf PDF
HistoricalData.pdf PDF
FA853424R0003_0002_.pdf PDF
L_M_25_June_2024.pdf PDF
TechnicalOrder_Refrigerator_5_20_24.pdf PDF
TechnicalOrder_Depot_Maintenance_5_20_24.pdf PDF
TechnicalOrder_Oven_5_20_24.pdf PDF
TechnicalOrder_Coffee_Maker_5_20_24.pdf PDF
TechnicalOrder_Technical_Manual_Work_Package_5_20_24.pdf PDF
FA853424R0003_0001.pdf PDF
ATGL_TEP_Attachment_5_20_24.xlsx XLSX spreadsheet
TechnicalOrder_Coffee_Maker_Rail_Assembly_5_20_24.pdf PDF
ATGL TDP_5_20_24.pdf PDF
Sections L and M_5_20_24.pdf PDF
Transportation 1653.pdf PDF
807 ATGL.pdf PDF
ATGL TEP_Attachment 2 Workbook 3.20.24.xlsx XLSX spreadsheet
Sections L and M.pdf PDF
FA853424R0003.pdf PDF
GFP Attachment.pdf PDF
ATGL QASP Final.pdf PDF
ATGL PWS 01 April.pdf PDF
CDRLS (2).pdf PDF
Packaging 158.pdf PDF
Preaward_Survey_of_Prospective_Contractor_Accounting_System_Checklist.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TO 13B4-5-6WC-1

AIR TRANSPORTABLE GALLEY/LAVATORY (ATGL)

INSPECTION REQUIREMENTS

SERV-AIR, INC

DAAB07-92-Z-0506

This manual supersedes TO 13B4-5-6WC-1 dated 15 September 2023.

DISCLOSURE NOTICE - This information is furnished upon the condition that it will not be released to another nation without the specific authority of the Department of the Air Force of the United States, that it will be used for military purposes only, that individual or corporate rights originating in the information, whether patented or not, will be respected, that the recipient will report promptly to the United States, any known or suspected compromise, and that the information will be provided substantially the same degree of security afforded it by the Department of Defense of the United States. Also, regardless of any other markings on the document, it will not be downgraded or declassified without written approval of the originating United States agency.

DISTRIBUTION STATEMENT C - Distribution authorized to U.S. Government agencies and their contractors (Controlled Technical Information, Export Controlled) (24 April 2024). Other requests for this document must be referred to 406 SCMS/GUEE, Robins AFB, GA 31098. Questions concerning technical content shall be referred to

AFLCMC/WNZ

WARNING - This document contains technical data whose export is restricted by the Arms Export Control Act (Section 2751 of Title 22, United States Code) or the Export Control Reform Act of 2018 (Chapter 58 Sections 4801-4852 of Title 50, United States Code). Violations of these export laws are subject to severe criminal penalties.

Disseminate in accordance with provisions of DoD Directive 5230.25 and DoD Instruction 2040.02.

HANDLING AND DESTRUCTION NOTICE - Comply with distribution statement and destroy by any method that will prevent disclosure of contents or reconstruction of the document.

Published Under Authority of the Secretary of the Air Force

24 APRIL 2024

Controlled by: Department of the Air Force Controlled by: AFLCMC/WNZ CUI Category: Controlled Technical Information Distribution Statement: C

POC: DSN 472-1807

CUI

LIST OF CHANGES

Publication History

Publication Date Revision Remarks

24 APRIL 2024 1 Incorporated source data RC-2024022985136

15 SEPTEMBER 2023 Original Publication

TOTAL NUMBER OF CARDS IN THIS PUBLICATION IS 30.

CUI TO 13B4-5-6WC-1

A

1 THIS WORK CARD IS A STEP-BY-STEP GUIDE IN ABBREVIATED FORM FOR USE AS A REFERENCE TO ENSURE ACCOMPLISHMENT OF SELECTED TASKS BY A PREDETERMINED SEQUENCE PROCEDURE. THE INTENT OF THIS WORK CARD IS TO ELIMINATE THE PROBABILITY OF OMISSION OF A STEP IN THE ACCOMPLISHMENT OF THE INTENDED TASK. THE PROCEDURES CONTAINED HEREIN ARE PRESENTED IN THE SHORTEST PRACTICAL FORM FOR USE BY QUALIFIED PERSONNEL AND ARE NOT INTENDED TO PROVIDE FULL TECHNICAL INSTRUC- TIONS. THIS WORK CARD PROVIDES, IN AN ABBREVIATED FORM, PROCEDURES FOR INSPECTIONS. THESE PROCEDURES ARE DERIVED FROM, BUT DO NOT REPLACE, THE DETAILED PROCEDURES CONTAINED IN TECHNICAL ORDERS (TOS). WHEN MALFUNCTIONS OCCUR, REFERENCE TO THE TO SHALL BE MADE.

2 THE AIR FORCE TECHNICAL ORDER (AFTO) FORMS 244/245 PROVIDE A MEANS TO DOCUMENT EQUIPMENT DELAYED DISCREPANCIES, CORRECTIVE ACTIONS, RECORD SERVICE, AND PERIODIC AND DEPOT INSPECTIONS.

3 THIS WORK CARD DECK IS BROKEN INTO SIX SECTIONS. Section 1 CONTAINS PERIODIC INSPECTION REQUIREMENTS WHICH ARE TO BE ACCOMPLISHED EVERY 450 HOURS/6 MONTHS. Section 2 IS A CONTINUATION OF THE 450 HOUR/6 MONTH PERIODIC INSPECTION REQUIRE- MENTS THAT ARE TO BE ACCOMPLISHED AFTER INSTALLATION INTO THE AIRCRAFT OR CONNECTION TO AN APPROPRIATE POWER SOURCE OFF AIRCRAFT. Section 3 CONTAINS PREFLIGHT REQUIREMENTS THAT ARE TO BE ACCOMPLISHED PRIOR TO USE OF THE UNIT AFTER INSTALLATION INTO THE AIRCRAFT. Section 4 CONTAINS POSTFLIGHT REQUIREMENTS THAT ARE TO BE ACCOMPLISHED AT THE TERMINATION OF THE FLIGHT. Section 5 CONTAINS DEPOT INSPECTION REQUIREMENTS WHICH ARE TO BE ACCOMPLISHED EVERY 5000 HOURS/FIVE YEARS. Section 6 CONTAINS DEPOT POST INSPECTION REQUIREMENTS WHICH ARE TO BE ACCOMPLISHED EVERY 5000 HOURS/

FIVE YEARS.

4 RECOMMENDED CHANGES TO THESE WORK CARDS SHALL BE SUBMITTED IN ACCORDANCE WITH TO 00-5-1.

5 THIS WORK CARD CONTAINS INSPECTIONS IN MULTIPLE SECTIONS FOR CORROSION. IF CORROSION IS FOUND AND AFFECTS THE INTEGRITY OF THE AIR TRANSPORTABLE GALLEY/LAVATORY (ATGL) STRUCTURE CONTACT THE AMC/A4 ASSET MANAGER FOR FURTHER

GUIDANCE.

CUI

PUBLICATION NUMBER INTRODUCTION CHANGE NO. CARD NO.

TO 13B4-5-6WC-1 INTRODUCTION 0 i

TO-13B4-5-6WC-1-001WORK AREA DIAGRAM

WORK AREA 1 - GALLEY AREA

WORK AREA 2 - LAVATORY AREA

WORK AREA 3 - RIGHT SIDE AREA

WORK AREA 4 - LEFT SIDE AREA

WORK AREA 5 - BOTTOM AREA

WORK AREA 6 - TOP AREA

WORK AREA DIAGRAM

PUBLICATION NUMBER INTRODUCTION CHANGE NO. CARD NO.

TO 13B4-5-6WC-1 INTRODUCTION 0 i

OPERATIONAL CHECKOUT

1.003 1 AT GB0 AIR FORCE TECHNICAL ORDER (AFTO) FORMS 244/245 FOR OPEN DISCREPANCIES.

2.012 1,2,4 AT GC0 PERFORM OPERATIONAL CHECKOUT IN ACCORDANCE WITH TECHNICAL ORDER (TO) 13B4-5-1.

GALLEY AREA

3.037 1 AT A00 REMOVE THE FOLLOWING ITEMS IN ACCORDANCE WITH TO 13B4-5-1:

A. OVENS.

B. COFFEE MAKERS.

C. REFRIGERATORS.

D. CONTROL PANEL.

4.010 1 AT AAA OVEN CAVITIES:

A. FOR CRACKS, CHIPPED OR PEELING PAINT, DENTS, CORROSION, LOOSE OR MISSING SCREWS, AND CLEANLINESS.

B. BONDING BRACKETS FOR SECURITY AND LOOSE OR MISSING HARDWARE.

C. SCREENS FOR DENTS, DISTORTION, AND LOOSE OR MISSING SCREWS.

D. SCREEN MOUNTS FOR CRACKS AND LOOSE OR MISSING RIVETS AND NUT PLATES.

E. GUIDE RAILS FOR CRACKS, DISTORTION, AND LOOSE OR MISSING SCREWS.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

1-001 1-6 APG 01:02 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

PERIODIC

INSPECTION

REQUIREMENTS

ELECTRICAL POWER SERVICE

SYS SUB OFF

F. ELECTRICAL CONNECTOR AND WIRING HARNESS FOR EVIDENCE OF OVERHEATING (INSULA-

TION DISCOLORATION OR DETERIORATION) AND SECURITY.

G. LIGHT BALLAST AND BRACKET FOR SECURITY AND LOOSE OR MISSING SCREWS.

H. LIGHT BALLAST WIRING HARNESS FOR SIGNS OF OVERHEATING (INSULATION DISCOLOR-

ATION OR DETERIORATION) AND CLAMPS FOR SECURITY.

I. LAVATORY ACCESS PANEL FOR DENTS, DISTORTION, AND LOOSE OR MISSING HARDWARE.

J. OVEN DOOR BUMPER FOR LOOSE OR MISSING RIVETS.

K. MAIN POWER ELECTRICAL CABLE FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLOR-

ATION AND DETERIORATION) AND CLAMPS FOR SECURITY.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

1-001 1-6 APG 01:02 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

PERIODIC

INSPECTION

REQUIREMENTS

5.008 1 AT ABA COFFEE MAKER CAVITIES:

A. FOR CRACKS, CHIPPED OR PEELING PAINT, DENTS, CORROSION. LOOSE OR MISSING SCREWS, AND CLEANLINESS.

B. RAILS FOR LOOSE OR MISSING SCREWS.

C. ELECTRICAL CONNECTOR AND WIRING HARNESS FOR EVIDENCE OF OVERHEATING (INSULA-

TION DISCOLORATION OR DETERIORATION) AND SECURITY.

D. WATER CONNECTOR FOR CORROSION AND SECURITY.

E. WATER DRAIN FOR CRACKS, CORROSION, OBSTRUCTION, SECURITY, AND CLEANLINESS.

F. SUMP SUPPORT ASSEMBLY AND SUMP TRAY ASSEMBLY FOR CHIPPED OR PEELING PAINT,

DENTS, CRACKS, LOOSE OR MISSING HARDWARE, AND SECURITY.

G. DRAIN STRAINER FOR DENTS, DISTORTION, AND CLEANLINESS.

6.007 1 AT ACA REFRIGERATOR CAVITIES:

A. FOR CRACKS, CHIPPED OR PEELING PAINT, DENTS, CORROSION, LOOSE OR MISSING SCREWS, AND CLEANLINESS.

B. BONDING BRACKETS FOR SECURITY AND LOOSE OR MISSING HARDWARE.

C. WALL BRACKETS FOR LOOSE OR MISSING HARDWARE.

D. RETAINING BAR FOR CRACKS AND LOOSE OR MISSING SCREWS.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

1-002 1-6 APG 00:15 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

PERIODIC

INSPECTION

REQUIREMENTS

E. PHENOLIC STRIPS FOR CRACKS, DETERIORATION, AND SECURITY.

F. VENT FANS FOR LOOSE OR MISSING HARDWARE AND CLEANLINESS.

G. VENT FAN WIRING HARNESS FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLORATION

OR DETERIORATION) AND CLAMPS FOR SECURITY.

H. DIRECT CURRENT (DC) POWER SUPPLY FOR EVIDENCE OF OVERHEATING (INSULATION

DISCOLORATION OR DETERIORATION) AND MOUNTING SECURITY.

I. DC POWER SUPPLY WIRING FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLORATION

OR DETERIORATION) AND CLAMPS FOR SECURITY.

J. ELECTRICAL CONNECTOR AND WIRING HARNESS FOR EVIDENCE OF OVERHEATING (INSULA-

TION DISCOLORATION OR DETERIORATION) AND SECURITY.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

1-002 1-6 APG 00:15 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

PERIODIC

INSPECTION

REQUIREMENTS

7.005 1 AT ADA CONTROL PANEL CAVITY:

A. FOR CRACKS, CHIPPED OR PEELING PAINT, DENTS, CORROSION, LOOSE OR MISSING SCREWS, AND CLEANLINESS.

B. MOUNTING BRACKETS FOR SECURITY AND LOOSE OR MISSING HARDWARE.

C. ELECTRICAL CONNECTORS AND WIRING HARNESS FOR EVIDENCE OF OVERHEATING (INSU-

LATION DISCOLORATION OR DETERIORATION) AND CLAMPS FOR SECURITY.

D. TERMINAL BLOCK COVER FOR CRACKS AND LOOSE OR MISSING HARDWARE.

E. TERMINAL BLOCK WIRING HARNESS FOR EVIDENCE OF OVERHEATING (INSULATION DISCOL-

ORATION OR DETERIORATION), CONNECTIONS FOR SECURITY, AND CLAMPS FOR SECURITY.

F. GROUNDING LUG FOR CONNECTION SECURITY, FRAYING WIRE, CORROSION, AND LOOSE OR

MISSING HARDWARE.

G. NAMEPLATE FOR DISTORTION AND LOOSE OR MISSING RIVETS.

8.003 1 AT AE0 WATER AND DRAIN HOSES FOR CRACKS, EVIDENCE OF LEAKS, AND LOOSE OR MISSING CLAMPS.

9.003 1 AT AF0 STORAGE DRAWERS:

A. FOR CRACKS, CHIPPED OR PEELING PAINT, DENTS, CORROSION, AND LOOSE OR MISSING

HARDWARE.

B. RAILS FOR SMOOTH OPERATION AND LOOSE OR MISSING SCREWS.

C. LATCHES FOR PROPER OPERATION AND LOOSE OR MISSING SCREWS.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

1-003 1-6 APG 00:20 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

PERIODIC

INSPECTION

REQUIREMENTS

10.005 1 AT AG0 STORAGE AND TRASH COMPARTMENT DOORS:

A. HINGE FOR FREEDOM OF OPERATION AND LOOSE OR MISSING RIVETS.

B. LATCHES FOR PROPER OPERATION AND LOOSE OR MISSING SCREWS.

C. STOPS FOR CRACKS, DISTORTION, AND LOOSE OR MISSING RIVETS.

D. RUBBER PADS FOR DETERIORATION AND SECURITY.

11.001 1 AT AH0 TRASH RECEPTACLE:

A. FOR CRACKED SEAMS, DENTS, AND CORROSION.

B. HANDLES FOR SPRING OPERATION, SECURITY, AND LOOSE OR MISSING SCREWS.

12.001 1 AT AH0 TRASH RECEPTACLE SPRING-HINGE DOOR FOR PROPER SPRING OPERATION, DENTS, AND

CRACKS.

13.001 1 AT AH0 TRASH RECEPTACLE COMPARTMENT PHENOLIC STRIPS FOR CRACKS, DETERIORATION, AND

SECURITY.

14.001 1 AT AI0 LIGHT ASSEMBLIES:

A. FOR CRACKED LENS AND SECURITY.

B. WIRING HARNESS FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLORATION OR

DETERIORATION) AND CLAMPS FOR SECURITY.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

1-003 1-6 APG 00:20 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

PERIODIC

INSPECTION

REQUIREMENTS

15.003 1 AT AJ0 COUNTERTOP AND WALL PANELS FOR CRACKS, CHIPPED OR PEELING PAINT, DENTS, CORROSION, AND LOOSE OR MISSING HARDWARE.

16.003 1 AT AK0 UNDER-THE-COUNTER SHELVES:

A. FOR DENTS AND CORROSION.

B. HANDLES FOR LOOSE OR MISSING SCREWS.

C. GUIDE RAILS FOR LOOSE OR MISSING SCREWS.

17.002 1 AT AL0 ELAPSED-TIME INDICATOR:

A. FOR CRACKED LENS AND SECURITY.

B. MOUNTING BRACKET FOR LOOSE OR MISSING SCREWS.

C. WIRING HARNESS FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLORATION OR

DETERIORATION) AND CLAMPS FOR SECURITY.

LAVATORY AREA

18.004 2 AT BY0 WALLS FOR CRACKS, CHIPPED OR PEELING PAINT, DENTS, CORROSION, LOOSE OR MISSING

HARDWARE, AND CLEANLINESS.

19.005 2 AT BA0 LAVATORY DOORS:

A. FOR DENTS AND CHIPPED OR PEELING PAINT.

B. VENTS FOR DENTS, CRACKS, LOOSE OR MISSING SCREWS, AND CLEANLINESS.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

1-004 1-6 00:23 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

PERIODIC

INSPECTION

REQUIREMENTS

SYS SUB

C. HINGES FOR FREEDOM OF OPERATION AND LOOSE OR MISSING RIVETS.

D. KNOB ASSEMBLY FOR PROPER OPERATION AND LOOSE OR MISSING HARDWARE.

E. SLIDE LOCK ASSEMBLY FOR PROPER OPERATION AND LOOSE OR MISSING HARDWARE.

F. COAT HANGER FOR SPRING OPERATION AND SECURITY.

G. RUBBER PAD FOR DETERIORATION AND SECURITY.

20.001 2 AT BNB LAVATORY OCCUPIED/EMERGENCY LIGHT LENS FOR CRACKS AND SECURITY.

21.003 2 AT BB0 POTABLE WATER TANK:

A. FOR DENTS AND LOOSE OR MISSING BOLTS.

B. SIGHT GAUGE FOR CRACKS, LEAKS, VISIBILITY, AND SECURITY.

C. FILL CONNECTOR FOR SECURITY AND LOOSE OR MISSING HARDWARE.

D. PADS FOR CUTS, DETERIORATION, AND SECURITY.

E. HANDLE FOR SPRING OPERATION, SECURITY, AND LOOSE OR MISSING HARDWARE.

22.001 2 AT BC0 CUP DISPENSER FOR DENTS AND SECURITY.

23.001 2 AT BD0 REMOVE TRASH RECEPTACLE ACCESS DOOR.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

1-004 1-6 00:23 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

PERIODIC

INSPECTION

REQUIREMENTS

SYS SUB

24.001 2 AT BD0 TRASH RECEPTACLE ACCESS DOOR FOR DENTS, CHIPPED OR PEELING PAINT, AND LOOSE OR

MISSING HARDWARE.

A. FOR CRACKED SEAMS, DENTS, AND CORROSION.

B. HANDLES FOR SPRING OPERATION, SECURITY, AND LOOSE OR MISSING SCREWS.

25.001 2 AT BE0 TRASH RECEPTACLE:

A. FOR CRACKED SEAMS, DENTS, AND CORROSION.

B. HANDLES FOR SPRING OPERATION, SECURITY, AND LOOSE OR MISSING SCREWS.

26.003 2 AT BF0 TRASH RECEPTACLE CAVITY:

A. FOR CRACKS, CHIPPED OR PEELING PAINT, DENTS, CORROSION, LOOSE OR MISSING HARD-

WARE, AND CLEANLINESS.

B. BONDING BRACKETS FOR SECURITY AND LOOSE OR MISSING HARDWARE.

C. PHENOLIC STRIPS FOR CRACKS, DETERIORATION, AND SECURITY.

D. GUIDES AND BRACKETS FOR LOOSE OR MISSING HARDWARE, AND CORROSION.

27.005 2 AT BG0 PLUMBING FOR LEAKS, CUTS, DETERIORATION, AND SECURITY.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

1-005 1-6 APG 00:48 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

PERIODIC

INSPECTION

REQUIREMENTS

NOTE

CHANGE FILTER EVERY 12 MONTHS.

28. WATER SYSTEM FILTER FOR LEAKS AND SECURITY.

29.003 2 AT BH0 WATER HEATER FOR LEAKS AND SECURITY. TEST/ADJUST PRESSURE RELIEF VALVES AND

THERMOSTAT IN ACCORDANCE WITH TO 13B4-5-1.

30.020 2 AT BI0 WATER PUMP FOR LEAKS AND SECURITY.

31.005 2 AT BK0 REMOVE TOILET SEAT AND SHROUD AND INSPECT HUMAN WASTE TANK IN ACCORDANCE WITH

TO 13B4-5-1.

32.010 2 AT BL0 HUMAN WASTE TANK:

A. WALLS FOR CRACKS, LEAKS, AND CLEANLINESS.

B. HOLD-DOWN RODS FOR SECURITY AND LOOSE OR MISSING HARDWARE.

C. PUMP MOTORS FOR LEAKS, SECURITY, LOOSE OR MISSING HARDWARE, CORROSION, AND

CLEANLINESS.

D. ELECTRICAL WIRING FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLORATION OR

DETERIORATION) AND CLAMPS FOR SECURITY.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

1-005 1-6 APG 00:48 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

PERIODIC

INSPECTION

REQUIREMENTS

DO NOT ALLOW THE EMERGENCY OXYGEN/VENTILATION FAN ENCLOSURE TO FALL.

ELECTRICAL WIRING CONNECTIONS, LOCATED BEHIND THE ENCLOSURE, MAY BE

DAMAGED.

33.002 2 AT BM0 REMOVE EMERGENCY OXYGEN/VENTILATION FAN ENCLOSURE IN ACCORDANCE WITH TO 13B4-5-1.

34.002 2 AT BM0 EMERGENCY OXYGEN/VENTILATION FAN ENCLOSURE FOR DENTS, CHIPPED OR PEELING PAINT, LOOSE OR MISSING HARDWARE, AND CORROSION.

35.002 2 AT BMA EMERGENCY PASSENGER OXYGEN SYSTEM (EPOS):

A. FOR SECURITY AND NO VISIBLE DAMAGE TO THE EPOS UNIT.

B. HUMIDITY DISK INDICATOR FOR PROPER COLOR (BLUE).

C. FOR A CURRENT INSPECTION DATE.

36.002 2 AT BM0 VENTILATION FAN:

A. FOR SECURITY AND LOOSE OR MISSING HARDWARE.

B. ELECTRICAL WIRING FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLORATION OR

DETERIORATION) AND CLAMPS FOR SECURITY.

37.001 2 AT BN0 LIGHT ASSEMBLY:

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

1-006 1-6 APG 00:22 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

PERIODIC

INSPECTION

REQUIREMENTS

A. FOR CRACKED LENS AND SECURITY.

B. ELECTRICAL WIRING FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLORATION AND

DETERIORATION) AND CLAMPS FOR SECURITY.

38.002 2 AT BZ0 SMOKE DETECTOR FOR SECURITY AND LOOSE OR MISSING HARDWARE (CHANGE BATTERY

EVERY 6 MONTHS).

39.001 2 AT BK0 TOILET SEAT AND SHROUD FOR CRACKS, SECURITY, AND CLEANLINESS.

40.001 2 AT BK0 TOILET BOWL FOR SECURITY AND CLEANLINESS.

41.001 2 AT BKA TOILET BOWL FLAPPER VALVE FOR PROPER OPERATION AND CLEANLINESS.

42.001 2 AT BP0 EMERGENCY CALL BUTTON FOR CRACKS AND SECURITY.

43.001 2 AT BK0 TOILET FLUSH HANDLE FOR LOOSE OR MISSING HARDWARE AND CLEANLINESS.

44.001 2 AT BQ0 ACCESS PANEL, LOCATED IN REAR OF LAVATORY, FOR DENTS, CHIPPED OR PEELING PAINT, LOOSE OR MISSING HARDWARE, AND CLEANLINESS.

45.001 2 AT BR0 WASH BASIN AND FIXTURES FOR SECURITY, LOOSE OR MISSING HARDWARE, AND CLEANLINESS.

46.001 2 AT BT0 MIRROR FOR SECURITY AND CLEANLINESS.

47.002 2 AT BU0 TOWEL AND TOILET PAPER DISPENSERS FOR SECURITY, LOOSE OR MISSING HARDWARE, AND

CLEANLINESS.

48.001 2 AT BRA SAFETY HANDLE FOR SECURITY AND CLEANLINESS.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

1-006 1-6 APG 00:22 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

PERIODIC

INSPECTION

REQUIREMENTS

49.001 2 AT BD0 TRASH RECEPTACLE SPRING-HINGE DOOR:

A. FOR PROPER SPRING OPERATION, DENTS, CHIPPED OR PEELING PAINT, LOOSE OR MISSING

HARDWARE, AND CLEANLINESS.

B. STOP FOR SECURITY AND LOOSE OR MISSING RIVETS.

50.002 2 AT BW0 STORAGE COMPARTMENT:

A. HINGE FOR FREEDOM OF OPERATION AND LOOSE OR MISSING RIVETS.

B. LATCH FOR PROPER OPERATION AND LOOSE OR MISSING SCREWS.

C. STOPS FOR CRACKS, DISTORTION, AND LOOSE OR MISSING RIVETS.

D. RUBBER PAD FOR DETERIORATION AND SECURITY.

51.001 2 AT BW0 REMOVE LOWER SHELF IN STORAGE COMPARTMENT.

52.001 2 AT BW0 LOWER SHELF FOR DENTS, CHIPPED OR PEELING PAINT, AND LOOSE OR MISSING HARDWARE.

53.001 2 AT BNA TERMINAL BLOCK COVER FOR CRACKS AND LOOSE OR MISSING HARDWARE.

54.001 2 AT BNA TERMINAL BLOCK WIRING HARNESS FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLOR-

ATION OR DETERIORATION), CONNECTIONS FOR SECURITY, AND RACEWAY COVER FOR SECU-

RITY.

55.001 2 AT BN0 LIGHT BALLAST:

A. FOR SECURITY AND LOOSE OR MISSING SCREWS.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

1-007 1-6 APG 00:27 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

PERIODIC

INSPECTION

REQUIREMENTS

B. WIRING HARNESS FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLORATION OR

DETERIORATION) AND RACEWAY COVER FOR SECURITY.

56.001 2 AT BX0 DC CONVERTER(S):

A. FOR SECURITY AND LOOSE OR MISSING SCREWS.

B. WIRING HARNESS FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLORATION OR

DETERIORATION) AND SECURITY.

57.002 2 AT BW0 INSTALL LOWER SHELF IN STORAGE COMPARTMENT.

58.005 2 AT BK0 INSTALL TOILET SEAT AND SHROUD IN ACCORDANCE WITH TO 13B4-5-1.

RIGHT SIDE AREA

59.004 3 AT CA0 WALLS FOR CRACKS, CHIPPED OR PEELING PAINT, DENTS, CORROSION, LOOSE OR MISSING

HARDWARE, AND CLEANLINESS.

60.002 3 AT CB0 ACCESS PANELS FOR DENTS AND LOOSE OR MISSING SCREWS.

61.004 3 AT CC0 FOLD-DOWN STEPS FOR PROPER SPRING OPERATION, CORROSION, AND LOOSE OR MISSING

HARDWARE.

62.001 3 AT CD0 LAVATORY VENT FOR DISTORTION, SECURITY, AND CLEANLINESS.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

1-007 1-6 APG 00:27 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

PERIODIC

INSPECTION

REQUIREMENTS

63.002 3 AT CE0 REFRIGERATOR VENT:

A. FOR DENTS, DISTORTION, LOOSE OR MISSING HARDWARE, AND CLEANLINESS.

B. FAN GUARDS FOR DISTORTION AND LOOSE OR MISSING HARDWARE.

64.002 3 AT CF0 STORAGE COMPARTMENT:

A. HINGE FOR FREEDOM OF OPERATION AND LOOSE OR MISSING RIVETS.

B. DOOR LATCH FOR PROPER OPERATION AND LOOSE OR MISSING SCREWS.

C. DOORSTOP FOR CRACKS, DISTORTION, AND LOOSE OR MISSING RIVETS.

D. RUBBER PAD FOR DETERIORATION AND SECURITY.

65.002 3 AT CG0 CATWALK:

A. FOR DENTS, CHIPPED OR PEELING PAINT, LOOSE OR MISSING HARDWARE, AND CLEANLINESS.

B. RUBBER FLOORING FOR RIPS, TEARS, AND SECURITY.

C. CATWALK EXTENSION BRACKETS AND PLATES FOR CHIPPED OR PEELING PAINT, LOOSE OR

MISSING HARDWARE, AND SECURITY.

66.002 3 AT CG0 CATWALK EXTENSION:

A. FOR DENTS, DISTORTION, CHIPPED OR PEELING PAINT, AND LOOSE OR MISSING RIVETS.

B. RUBBER FLOORING FOR RIPS, TEARS, AND SECURITY.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

1-008 1-6 APG 00:16 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

PERIODIC

INSPECTION

REQUIREMENTS

C. SUPPORT BRACKET FOR LOOSE OR MISSING HARDWARE, AND SECURITY.

D. VELCRO® STRAPS FOR RIPS, TEARS, DETERIORATION, AND SECURITY.

E. HINGE FOR LOOSE OR MISSING RIVETS.

67.002 3 AT CH0 TARP STORAGE COVER:

A. FOR RIPS, TEARS, AND FRAYING.

B. FABRIC FOR WATERPROOFING.

C. VELCRO® STRAPS FOR RIPS, TEARS, DETERIORATION, AND SECURITY.

LEFT SIDE AREA

68.004 4 AT DA0 WALLS FOR CRACKS, CHIPPED OR PEELING PAINT, DENTS, CORROSION, LOOSE OR MISSING

HARDWARE, AND CLEANLINESS.

69.002 4 AT DB0 STORAGE COMPARTMENT:

A. HINGE FOR FREEDOM OF OPERATION AND LOOSE OR MISSING RIVETS.

B. DOOR LATCH FOR PROPER OPERATION AND LOOSE OR MISSING SCREWS.

C. DOORSTOP FOR CRACKS, DISTORTION, AND LOOSE OR MISSING RIVETS.

D. RUBBER PAD FOR DETERIORATION AND SECURITY.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

1-008 1-6 APG 00:16 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

PERIODIC

INSPECTION

REQUIREMENTS

70.003 4 AT DC0 CABLE RESTRAINT:

A. FOR CRACKS, DENTS, CHIPPED OR PEELING PAINT, AND LOOSE OR MISSING HARDWARE.

B. STORAGE PINS FOR SECURITY AND LOOSE OR MISSING HARDWARE.

C. CABLE CLAMPS FOR SECURITY AND LOOSE OR MISSING HARDWARE.

D. MOUNTING BRACKETS FOR CRACKS, DENTS, CHIPPED OR PEELING PAINT, AND SECURITY.

71.003 4 AT DD0 POWER RECEPTACLE PANEL:

A. FOR SECURITY AND LOOSE OR MISSING RIVETS.

B. CONNECTORS FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLORATION OR DETERIO-

RATION), BENT PINS, SECURITY, AND LOOSE OR MISSING HARDWARE.

C. GROUNDING LUG FOR SECURITY, CORROSION, AND LOOSE OR MISSING HARDWARE.

D. NAMEPLATES FOR DISTORTION AND LOOSE OR MISSING RIVETS.

72.002 4 AT DF0 REFRIGERATOR VENT FOR DENTS, DISTORTION, LOOSE OR MISSING HARDWARE, AND CLEANLI-

NESS.

73.001 4 AT DE0 LAVATORY VENT FOR DISTORTION, SECURITY, AND CLEANLINESS.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

1-009 1-6 APG 00:19 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

PERIODIC

INSPECTION

REQUIREMENTS

NOTE

ENSURE HUMAN WASTE TANK IS DRAINED AND RINSED IN ACCORDANCE WITH TO

13B4-5-1 BEFORE PERFORMING INSPECTION ON WASTE TANK DRAIN.

74.003 4 AT DG0 HUMAN WASTE TANK DRAIN HOSE:

A. FOR CUTS, CRACKS, DETERIORATION, AND EVIDENCE OF LEAKAGE.

B. CLAMPS FOR SECURITY.

C. STORAGE BRACKETS FOR CRACKS, CHIPPED OR PEELING PAINT, AND LOOSE OR MISSING

HARDWARE.

75.003 4 AT DH0 HUMAN WASTE TANK DRAIN VALVE:

A. FOR EVIDENCE OF LEAKAGE, SECURITY, AND LOOSE OR MISSING BOLTS.

B. HANDLE FOR OPERATION, SECURITY, AND LOOSE OR MISSING HARDWARE.

76.002 4 AT DL0 HUMAN WASTE TANK RINSE VALVE FOR EVIDENCE OF LEAKAGE, SECURITY, AND LOOSE OR

MISSING BOLTS.

77.002 4 AT DI0 HUMAN WASTE TANK VENT HOSE:

A. FOR CUTS, CRACKS, DETERIORATION, AND EVIDENCE OF LEAKAGE.

B. STORAGE BRACKETS FOR CRACKS, CHIPPED OR PEELING PAINT, AND LOOSE OR MISSING

HARDWARE.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

1-009 1-6 APG 00:19 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

PERIODIC

INSPECTION

REQUIREMENTS

78.001 4 AT DJ0 PRE-CHARGE AND FULL LIGHT LENSES FOR CRACKS AND SECURITY.

79.002 4 AT DK0 ELECTRICAL POWER CABLE:

A. WIRING HARNESS FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLORATION AND

DETERIORATION).

B. CONNECTORS FOR EVIDENCE OF OVERHEATING, BENT PINS, SECURITY, AND LOOSE OR

MISSING HARDWARE.

TOP AREA

80.004 6 AT EA0 SURFACE FOR CRACKS, CHIPPED OR PEELING PAINT, DENTS, CORROSION, LOOSE OR MISSING

HARDWARE, AND CLEANLINESS.

81.001 6 AT EB0 HAND SUPPORT FOR DENTS AND LOOSE OR MISSING SCREWS.

82.001 6 AT EC0 BAGGAGE TIE-DOWN TRACK FOR LOOSE OR MISSING SCREWS.

83.002 6 AT ED0 POTABLE WATER TANK ACCESS PANEL AND CAP FOR SECURITY.

BOTTOM AREA

84.003 5 AT FA0 463L CARGO PALLET FOR CORROSION, SECURITY, AND LOOSE OR MISSING HARDWARE.

85.003 5 AT FB0 D-RINGS FOR CORROSION AND SECURITY.

86.003 5 AT FC0 TIE-DOWN RINGS FOR CORROSION AND SECURITY.

87.003 5 AT FG0 VELCRO® FOR RIPS, TEARS, DETERIORATION, AND SECURITY.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

1-010 1-6 APG 00:34 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

PERIODIC

INSPECTION

REQUIREMENTS

88.001 5 AT FD0 FORKLIFT TINE TUNNELS FOR DENTS, CORROSION, SECURITY, AND CLEANLINESS.

89.001 5 AT FE0 BUMPERS FOR TEARS, DETERIORATION, AND SECURITY.

90.001 5 AT FF0 J-BOLT RUBBER SPACER GAP FOR PROPER FITMENT USING SPACER TOOL.

91. J-BOLT LOCKNUT FOR PROPER TORQUE (50 FOOT-POUNDS).

REFRIGERATOR

92.004 1 AT AC0 INTERIOR AND EXTERIOR WALLS FOR DENTS, CORROSION, LOOSE OR MISSING HARDWARE, AND

CLEANLINESS.

93.004 1 AT AC0 DOOR:

A. FOR DENTS, LOOSE OR MISSING HARDWARE, AND CLEANLINESS.

B. HINGE FOR FREEDOM OF OPERATION AND LOOSE OR MISSING BOLTS.

C. HANDLE AND LATCH FOR PROPER OPERATION AND LOOSE OR MISSING HARDWARE.

D. SEAL FOR CUTS, TEARS, DETERIORATION, CLEANLINESS, AND SECURITY.

E. LOCK FOR PROPER OPERATION, SECURITY, AND LOOSE OR MISSING HARDWARE.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

1-010 1-6 APG 00:34 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

PERIODIC

INSPECTION

REQUIREMENTS

94.003 1 AT AC0 TRAYS:

A. FOR DENTS, DISTORTION, AND CLEANLINESS.

B. GUIDES FOR DISTORTION, CORROSION, AND LOOSE OR MISSING RIVETS.

C. GUIDE MOUNTS FOR DISTORTION, CORROSION, AND SECURITY.

95.001 1 AT AC0 ELECTRICAL CONNECTOR FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLORATION OR

DETERIORATION), BENT PINS, AND LOOSE OR MISSING HARDWARE.

96.005 1 AT AC0 REMOVE REAR ACCESS PANEL IN ACCORDANCE WITH TO 13B5-9-1.

97.002 1 AT AC0 FANS FOR SECURITY AND LOOSE OR MISSING HARDWARE.

98.002 1 AT AC0 FAN GRILL GUARDS FOR DISTORTION AND SECURITY.

99.001 1 AT AC0 COOLING FINS FOR CLEANLINESS.

100.002 1 AT AC0 ELECTRICAL WIRING FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLORATION OR

DETERIORATION) AND CLAMPS FOR SECURITY.

101.005 1 AT AC0 INSTALL REAR ACCESS PANEL IN ACCORDANCE WITH TO 13B5-9-1.

102.001 1 AT AC0 TEMPERATURE INDICATOR FOR SECURITY.

OVEN

103.004 1 AT AA0 INTERIOR AND EXTERIOR WALLS FOR DENTS, CORROSION, LOOSE OR MISSING HARDWARE, AND

CLEANLINESS.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

1-011 1-6 APG 00:34 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

PERIODIC

INSPECTION

REQUIREMENTS

104.003 1 AT AA0 DOOR:

A. FOR DENTS, LOOSE OR MISSING HARDWARE, AND CLEANLINESS.

B. HINGE FOR FREEDOM OF OPERATION AND LOOSE OR MISSING SCREWS.

C. HANDLE AND LATCH FOR PROPER OPERATION AND LOOSE OR MISSING HARDWARE.

D. SEAL FOR CUTS, TEARS, DETERIORATION, AND SECURITY.

105.001 1 AT AA0 CIRCULATION FAN FOR DISTORTION, SECURITY, AND LOOSE OR MISSING HARDWARE.

106.001 1 AT AA0 HEATING ELEMENTS FOR SECURITY AND LOOSE OR MISSING HARDWARE.

107.003 1 AT AA0 TRAY CONTAINER:

A. FOR DENTS, DISTORTION, CORROSION, AND LOOSE OR MISSING HARDWARE.

B. TRAYS FOR DENTS, DISTORTION, CORROSION, AND CLEANLINESS.

C. RACKS FOR DISTORTION AND SECURITY.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

1-011 1-6 APG 00:34 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

PERIODIC

INSPECTION

REQUIREMENTS

108.003 1 AT AA0 SWITCH PANEL:

A. FOR DENTS, SECURITY, AND LOOSE OR MISSING HARDWARE.

B. VENTS FOR SECURITY AND CLEANLINESS.

C. TIMER AND TEMPERATURE SWITCHES FOR SECURITY.

D. LIGHTS FOR SECURITY.

E. ELECTRICAL CONNECTOR FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLORATION

OR DETERIORATION), BENT PINS, AND LOOSE OR MISSING HARDWARE.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

1-012 1 APG 00:03 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

PERIODIC

INSPECTION

REQUIREMENTS

COFFEE MAKER

1.004 1 AT AB0 WALLS FOR DENTS, CORROSION, LOOSE OR MISSING HARDWARE, AND CLEANLINESS.

2.001 1 AT AB0 LIGHT SWITCH COVERS FOR CUTS, TEARS, AND SECURITY.

3.002 1 AT AB0 COFFEE POT LOCK FOR PROPER OPERATION AND LOOSE OR MISSING HARDWARE.

4.002 1 AT AB0 BREW TRAY FOR CRACKS AND CLEANLINESS.

5.001 1 AT AB0 HOT WATER SPIGOT FOR LOOSE OR MISSING HARDWARE, OBSTRUCTIONS, AND CLEANLINESS.

6.003 1 AT AB0 BASE:

A. FOR CORROSION AND LOOSE OR MISSING HARDWARE.

B. DRAIN VALVE FOR OBSTRUCTIONS, CORROSION, AND LOOSE OR MISSING HARDWARE.

C. DRAIN FOR OBSTRUCTIONS AND CORROSION.

7.001 1 AT AB0 ELECTRICAL CONNECTOR FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLORATION OR

DETERIORATION), BENT PINS, AND LOOSE OR MISSING HARDWARE.

8.001 1 AT AB0 WATER CONNECTOR FOR CORROSION AND SECURITY.

9.003 1 AT AB0 ACCESSIBLE WIRING FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLORATION OR

DETERIORATION) AND CLAMPS FOR SECURITY.

10.004 1 AT AB0 ACCESSIBLE PLUMBING FOR EVIDENCE OF LEAKAGE AND SECURITY.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

2-001 1 APG 00:41 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

PERIODIC

INSPECTION

REQUIREMENTS

SYS SUB ON/OFF

CONTROL PANEL

11.003 1 AT AD0 WALLS FOR CRACKS, CHIPPED OR PEELING PAINT, DENTS, CORROSION, LOOSE OR MISSING

HARDWARE, AND CLEANLINESS.

12.004 1 AT AD0 CIRCUIT BREAKERS FOR CRACKS AND SECURITY.

13.003 1 AT AD0 INDICATOR LIGHTS FOR CRACKED LENS AND SECURITY.

14.003 1 AT AD0 ELECTRICAL CONNECTORS FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLORATION OR

DETERIORATION), BENT PINS, AND LOOSE OR MISSING HARDWARE.

15.003 1 AT AD0 ACCESSIBLE WIRING FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLORATION OR

DETERIORATION) AND CLAMPS FOR SECURITY.

16.001 1 AT AD0 TERMINAL BLOCK COVER FOR CRACKS AND LOOSE OR MISSING HARDWARE.

17.001 1 AT AD0 TERMINAL BLOCK WIRING HARNESS FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLOR-

ATION OR DETERIORATION), CONNECTIONS FOR SECURITY, AND CLAMPS FOR SECURITY.

18.001 1 AT AD0 GROUNDING LUG FOR CONNECTION SECURITY, FRAYING WIRE, CORROSION, AND LOOSE OR

MISSING HARDWARE.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

2-001 1 APG 00:41 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

PERIODIC

INSPECTION

REQUIREMENTS

POST INSPECTION

19.037 1 AT GAO INSTALL THE FOLLOWING ITEMS IN ACCORDANCE WITH TECHNICAL ORDER (TO) 13B4-5-1:

A. OVENS.

B. COFFEE MAKERS.

C. REFRIGERATORS.

D. CONTROL PANEL.

NOTE

CHECK AIR TRANSPORTABLE GALLEY/LAVATORY (ATGL) FOR LEAKS AND MALFUNC-

TIONS DURING OPERATIONAL CHECKOUT.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

2-002 1 APG 00:37 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

PERIODIC

INSPECTION

REQUIREMENTS

GENERAL

1.003 1 AT A00 AIR FORCE TECHNICAL ORDER (AFTO) FORM 244/245 FOR OPEN DISCREPANCIES.

2.005 5 AT A00 AIR TRANSPORTABLE GALLEY/LAVATORY (ATGL) FOR INSTALLATION, SECURITY, ROCKING

INHIBITORS INSTALLED, AND WALKWAY EXTENSION INSTALLED, IF APPLICABLE.

GALLEY/LAVATORY/LEFT SIDE AREAS

3.005 1 AT GA0 PERFORM EQUIPMENT INVENTORY.

4.001 1 AT AH0 TRASH RECEPTACLE BAG INSTALLED.

5.001 2 AT BB0 POTABLE WATER TANK FOR SERVICE.

6.001 2 AT BB0 5-GALLON PORTABLE WATER CONTAINER FOR SECURITY.

7.002 2 AT BE0 TRASH RECEPTACLE BAG INSTALLED.

8.001 2 AT BZ0 SMOKE DETECTOR (PUSH-TO-TEST) FOR PROPER OPERATION.

9.001 2 AT BMA EMERGENCY PASSENGER OXYGEN SYSTEM (EPOS) FOR BLUE STRIPE INDICATION.

10.003 4 AT DK0 POWER CABLE FOR INSTALLATION AND SECURITY.

11.001 4 AT DI0 VENT HOSE FOR INSTALLATION AND SECURITY.

OPERATIONAL CHECKOUT

12.012 1,2,4 AT GC0 PERFORM OPERATIONAL CHECKOUT IN ACCORDANCE WITH TECHNICAL ORDER (TO) 13B4-5-1.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

3-001 1,2,4,5 00:36 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

PREFLIGHT

INSPECTION

REQUIREMENTS

1.003 1 AT 000 AIR FORCE TECHNICAL ORDER (AFTO) FORM 244/245 FOR OPEN DISCREPANCIES.

2.012 1,2,4 AT 000 PERFORM OPERATIONAL CHECKOUT IN ACCORDANCE WITH TECHNICAL ORDER (TO) 13B4-5-1.

GALLEY/LAVATORY AREAS

3.004 1 AT AC0 REFRIGERATOR:

A. INTERIOR AND EXTERIOR SURFACES FOR CLEANLINESS.

B. DOORS FOR PROPER LATCHING.

C. SEALS FOR CUTS, TEARS, DETERIORATION, AND SECURITY.

4.004 1 AT AA0 OVENS:

A. INTERIOR AND EXTERIOR SURFACES FOR CLEANLINESS.

B. DOOR FOR PROPER LATCHING.

C. SEALS FOR CUTS, TEARS, DETERIORATION, AND SECURITY.

5.003 1 AT AB0 COFFEE MAKER FOR EVIDENCE OF LEAKAGE AND CLEANLINESS.

6.001 1 AT AH0 TRASH RECEPTACLE BAG INSTALLED.

7.005 1 AT GA0 PERFORM EQUIPMENT INVENTORY.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

4-001 1-6 00:46 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

POSTFLIGHT

INSPECTION

REQUIREMENTS

8.004 2 AT BY0 WALLS AND FLOORS FOR CLEANLINESS.

9.002 2 AT BR0 WASH BASIN, FIXTURES, AND MIRROR FOR CLEANLINESS.

10.002 2 AT BU0 TOWEL AND TOILET PAPER DISPENSERS FOR PRODUCTS INSTALLED.

11.001 2 AT BZ0 SMOKE DETECTOR (PUSH-TO-TEST) FOR PROPER OPERATION.

12.001 2 AT BK0 TOILET SEAT AND SHROUD FOR CLEANLINESS.

13.001 2 AT BKA INSPECT FOR EXCESSIVE BLUE WATER IN TOILET BOWL.

14.001 2 AT BMA EMERGENCY PASSENGER OXYGEN SYSTEM (EPOS) FOR BLUE STRIPE INDICATION.

15.001 2 AT BB0 POTABLE WATER TANK FOR SECURITY, EVIDENCE OF LEAKAGE, AND PROPER SERVICE.

16.001 2 AT BE0 TRASH RECEPTACLE BAG INSTALLED.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

4-001 1-6 00:46 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

POSTFLIGHT

INSPECTION

REQUIREMENTS

RIGHT/LEFT SIDE AREAS

1.002 3 AT CA0 WALLS FOR CLEANLINESS.

2.002 3 AT CC0 FOLD-DOWN STEPS FOR SECURITY.

3.002 3 AT CB0 VENT AND ACCESS PANELS FOR SECURITY.

4.002 3 AT CG0 CATWALK EXTENSION FOR SECURITY.

5.002 4 AT CA0 WALLS FOR CLEANLINESS.

6.001 4 AT DC0 CABLE RESTRAINT FOR SECURITY.

7.001 4 AT DD0 POWER RECEPTACLE PANEL CONNECTORS FOR SIGNS OF OVERHEATING (INSULATION DISCOL-

ORATION AND DETERIORATION) AND SECURITY.

8.002 4 AT CB0 VENT AND ACCESS PANELS FOR SECURITY.

9.002 4 AT BL0 HUMAN WASTE TANK:

A. DRAIN HOSE FOR EVIDENCE OF LEAKAGE AND SECURITY.

B. DRAIN VALVE HANDLE FOR SECURITY.

C. RINSE VALVE FOR EVIDENCE OF LEAKAGE AND SECURITY.

D. VENT HOSE FOR EVIDENCE OF LEAKAGE AND SECURITY.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

4-002 3-6 00:27 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

POSTFLIGHT

INSPECTION

REQUIREMENTS

BOTTOM/TOP AREAS

10.002 5 AT FA0 463L CARGO PALLET FOR SECURITY.

11.002 5 AT FB0 TIE-DOWN AND D-RINGS FOR SECURITY.

12.002 5 AT FG0 VELCRO® FOR SECURITY.

13.002 6 AT EA0 SURFACE FOR CLEANLINESS.

14.001 6 AT EB0 HAND SUPPORT AND BAGGAGE RESTRAINT RAILS FOR SECURITY.

15.002 6 AT BB0 POTABLE WATER TANK ACCESS PANEL AND CAP FOR SECURITY.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

4-002 3-6 00:27 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

POSTFLIGHT

INSPECTION

REQUIREMENTS

1.003 1 AT GB0 AIR FORCE TECHNICAL ORDER (AFTO) FORM 244/245 FOR OPEN DISCREPANCIES.

2.020 4 AT BL0 FLUSH AND DRAIN HUMAN WASTE TANK IN ACCORDANCE WITH TECHNICAL ORDER (TO) 13B4- 5-1.

3.030 2 AT BG0 DRAIN WATER SYSTEM IN ACCORDANCE WITH TO 13B4-5-1.

GALLEY AREA

4.052 1 AT A00 REMOVE THE FOLLOWING IN ACCORDANCE WITH TO 13B4-5-1:

A. OVENS.

B. COFFEE MAKER AND RAIL ASSEMBLIES.

C. REFRIGERATORS.

D. CONTROL PANEL.

E. ACCESS PANEL.

F. TRASH RECEPTACLES.

5.010 1 AT AAA OVEN CAVITIES:

A. FOR CRACKS, CHIPPED OR PEELING PAINT, DENTS, CORROSION, LOOSE OR MISSING SCREWS, AND CLEANLINESS.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

5-001 1,2,4 01:55 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

DEPOT

INSPECTION

REQUIREMENTS

B. BONDING BRACKETS FOR SECURITY AND LOOSE OR MISSING SCREWS.

C. SCREENS FOR DENTS, DISTORTION, AND LOOSE OR MISSING SCREWS.

D. SCREEN MOUNTS FOR CRACKS AND LOOSE OR MISSING RIVETS AND NUT PLATES.

E. GUIDE RAILS FOR CRACKS, DISTORTION, AND LOOSE OR MISSING SCREWS.

F. ELECTRICAL CONNECTOR AND WIRING HARNESS FOR EVIDENCE OF OVERHEATING (INSULA-

TION DISCOLORATION AND DETERIORATION) AND SECURITY.

G. LIGHT BALLAST AND BRACKET FOR SECURITY AND LOOSE OR MISSING SCREWS.

H. LIGHT BALLAST WIRING HARNESS FOR EVIDENCE OF OVERHEATING (INSULATION DISCOL-

ORATION AND DETERIORATION), AND CLAMPS FOR SECURITY.

I. LAVATORY ACCESS PANEL FOR DENTS, DISTORTION, AND LOOSE OR MISSING HARDWARE.

J. OVEN DOOR BUMPER FOR LOOSE OR MISSING RIVETS.

K. MAIN POWER ELECTRICAL CABLE FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLOR-

ATION AND DETERIORATION) AND CLAMPS FOR SECURITY.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

5-001 1,2,4 01:55 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

DEPOT

INSPECTION

REQUIREMENTS

6.006 1 AT ABA COFFEE MAKER CAVITIES:

A. FOR CRACKS, CHIPPED OR PEELING PAINT, DENTS, CORROSION, LOOSE OR MISSING SCREWS, AND CLEANLINESS.

B. ELECTRICAL CONNECTOR AND WIRING HARNESS FOR EVIDENCE OF OVERHEATING (INSULA-

TION DISCOLORATION AND DETERIORATION), AND SECURITY.

C. SUMP SUPPORT ASSEMBLY AND SUMP TRAY ASSEMBLY FOR CHIPPED OR PEELING PAINT,

DENTS, CRACKS, LOOSE OR MISSING HARDWARE, AND SECURITY.

D. DRAIN STRAINER FOR DENTS, DISTORTION, AND CLEANLINESS.

7.007 1 AT ACA REFRIGERATOR CAVITIES:

A. FOR CRACKS, CHIPPED OR PEELING PAINT, DENTS, CORROSION, LOOSE OR MISSING SCREWS, AND CLEANLINESS.

B. BONDING BRACKETS FOR SECURITY AND LOOSE OR MISSING SCREWS.

C. WALL BRACKETS FOR LOOSE OR MISSING HARDWARE.

D. RETAINING BAR FOR CRACKS AND LOOSE OR MISSING SCREWS.

E. PHENOLIC STRIPS FOR CRACKS, DETERIORATION, AND SECURITY.

F. VENT FANS FOR LOOSE OR MISSING HARDWARE AND CLEANLINESS.

G. VENT FAN WIRING HARNESS FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLORATION

AND DETERIORATION) AND CLAMPS FOR SECURITY.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

5-002 1,2,4 00:21 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

DEPOT

INSPECTION

REQUIREMENTS

H. DIRECT CURRENT (DC) POWER SUPPLY FOR EVIDENCE OF OVERHEATING AND MOUNTING

SECURITY.

I. DC POWER SUPPLY WIRING FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLORATION

AND DETERIORATION), AND CLAMPS FOR SECURITY.

J. ELECTRICAL CONNECTOR AND WIRING HARNESS FOR EVIDENCE OF OVERHEATING (INSULA-

TION DISCOLORATION AND DETERIORATION) AND SECURITY.

8.005 1 AT ADA CONTROL PANEL CAVITY:

A. FOR CRACKS, CHIPPED OR PEELING PAINT, DENTS, CORROSION, LOOSE OR MISSING SCREWS, AND CLEANLINESS.

B. MOUNTING BRACKETS FOR SECURITY AND LOOSE OR MISSING HARDWARE.

C. ELECTRICAL CONNECTORS AND WIRING HARNESSES FOR EVIDENCE OF OVERHEATING

(INSULATION DISCOLORATION AND DETERIORATION), AND CLAMPS FOR SECURITY.

D. TERMINAL BLOCK COVER FOR CRACKS AND LOOSE OR MISSING HARDWARE.

E. TERMINAL BLOCK WIRING HARNESS FOR EVIDENCE OF OVERHEATING (INSULATION DISCOL-

ORATION AND DETERIORATION), CONNECTIONS FOR SECURITY, AND CLAMPS FOR SECURITY.

F. GROUNDING LUG FOR CONNECTION SECURITY, FRAYING WIRE, CORROSION, AND LOOSE OR

MISSING HARDWARE.

G. NAMEPLATE FOR DISTORTION AND LOOSE OR MISSING RIVETS.

9.003 1 AT AE0 WATER AND DRAIN HOSES FOR CRACKS, EVIDENCE OF LEAKS, AND LOOSE OR MISSING CLAMPS.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

5-002 1,2,4 00:21 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

DEPOT

INSPECTION

REQUIREMENTS

10.003 1 AT AF0 STORAGE DRAWERS:

A. FOR CRACKS, CHIPPED OR PEELING PAINT, DENTS, CORROSION, AND LOOSE OR MISSING

HARDWARE.

B. RAILS FOR SMOOTH OPERATION AND LOOSE OR MISSING SCREWS.

C. LATCHES FOR PROPER OPERATION AND LOOSE OR MISSING SCREWS.

11.005 1 AT AG0 STORAGE AND TRASH COMPARTMENT DOORS:

A. HINGE FOR FREEDOM OF OPERATION AND LOOSE OR MISSING RIVETS.

B. LATCHES FOR PROPER OPERATION AND LOOSE OR MISSING SCREWS.

C. STOPS FOR CRACKS, DISTORTION, AND LOOSE OR MISSING RIVETS.

D. RUBBER PADS FOR DETERIORATION AND SECURITY.

12.001 1 AT AH0 TRASH RECEPTACLE SPRING HINGE DOOR FOR PROPER SPRING OPERATION, DENTS, AND

CRACKS.

13.001 1 AT AH0 TRASH RECEPTACLE COMPARTMENT PHENOLIC STRIPS FOR CRACKS, DETERIORATION, AND

SECURITY.

14.001 1 AT AI0 LIGHT ASSEMBLIES:

A. FOR CRACKED LENS AND SECURITY.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

5-003 1,2,4 00:19 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

DEPOT

INSPECTION

REQUIREMENTS

B. WIRING HARNESS FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLORATION AND

DETERIORATION), AND CLAMPS FOR SECURITY.

15.003 1 AT AJ0 COUNTERTOP AND WALL PANELS FOR CRACKED OR PEELING PAINT, DENTS, CORROSION, AND

LOOSE OR MISSING HARDWARE.

16.003 1 AT AK0 UNDER THE COUNTER SHELVES:

A. FOR DENTS AND CORROSION.

B. HANDLES FOR LOOSE OR MISSING SCREWS.

C. GUIDE RAILS FOR LOOSE OR MISSING SCREWS.

17.002 1 AT AL0 ELAPSED-TIME INDICATOR:

A. FOR CRACKED LENS AND SECURITY.

B. MOUNTING BRACKET FOR LOOSE OR MISSING SCREWS.

C. WIRING HARNESS FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLORATION AND

DETERIORATION), AND CLAMPS FOR SECURITY.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

5-003 1,2,4 00:19 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

DEPOT

INSPECTION

REQUIREMENTS

LAVATORY AREA

18.054 2 AT B00 REMOVE THE FOLLOWING ITEMS IN ACCORDANCE WITH TO 13B4-5-1.

A. POTABLE WATER TANK.

B. ACCESS PANELS.

C. TRASH RECEPTACLES.

D. TOILET SEAT AND SHROUD.

E. HUMAN WASTE TANK.

19.004 2 AT BY0 WALLS FOR CRACKS, CHIPPED OR PEELING PAINT, DENTS, CORROSION, LOOSE OR MISSING

HARDWARE, AND CLEANLINESS.

20.004 2 AT BA0 LAVATORY DOORS:

A. FOR DENTS AND CHIPPED OR PEELING PAINT.

B. VENTS FOR DENTS, CRACKS, LOOSE OR MISSING SCREWS, AND CLEANLINESS.

C. HINGES FOR FREEDOM OF OPERATION AND LOOSE OR MISSING RIVETS.

D. KNOB ASSEMBLY FOR PROPER OPERATION AND LOOSE OR MISSING HARDWARE.

E. SLIDE LOCK ASSEMBLY FOR PROPER OPERATION OR LOOSE OR MISSING HARDWARE.

F. COAT HANGER FOR SPRING OPERATION AND SECURITY.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

5-004 1,2,4 01:38 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

DEPOT

INSPECTION

REQUIREMENTS

G. STOP RUBBER PAD FOR DETERIORATION AND SECURITY.

21.001 2 AT BN0 LAVATORY OCCUPIED/EMERGENCY LIGHT LENS FOR CRACKS AND SECURITY.

22.001 2 AT BD0 TRASH RECEPTACLE ACCESS DOOR FOR DENTS, CHIPPED OR PEELING PAINT, AND LOOSE OR

MISSING HARDWARE.

23.001 2 AT BD0 REMOVE TRASH RECEPTACLE ACCESS DOOR.

24.003 2 AT BF0 TRASH RECEPTACLE CAVITY:

A. FOR CRACKS, CHIPPED OR PEELING PAINT, DENTS, CORROSION, LOOSE OR MISSING HARD-

WARE, AND CLEANLINESS.

B. BONDING BRACKETS FOR SECURITY AND LOOSE OR MISSING SCREWS.

C. PHENOLIC STRIPS FOR CRACKS, DETERIORATION, AND SECURITY.

D. GUIDES AND BRACKETS FOR LOOSE OR MISSING HARDWARE AND CORROSION.

25.005 2 AT BG0 PLUMBING FOR LEAKS, CUTS, DETERIORATION, AND SECURITY.

26.003 2 AT BH0 WATER SYSTEM FILTER FOR LEAKS AND SECURITY.

27.020 2 AT BI0 WATER HEATER FOR LEAKS AND SECURITY. TEST/ADJUST PRESSURE RELIEF VALVE AND THER-

MOSTAT IN ACCORDANCE WITH TO 13B4-5-1.

28.002 2 AT BJ0 WATER PUMP FOR LEAKS AND SECURITY.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

5-004 1,2,4 01:38 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

DEPOT

INSPECTION

REQUIREMENTS

DO NOT ALLOW THE EMERGENCY OXYGEN/VENTILATION FAN ENCLOSURE TO FALL.

ELECTRICAL WIRING CONNECTIONS, LOCATED BEHIND THE ENCLOSURE, MAY BE

DAMAGED.

29.002 2 AT BM0 REMOVE THE EMERGENCY OXYGEN/VENTILATION FAN ENCLOSURE IN ACCORDANCE WITH TO 13B4-5-1.

30.001 2 AT BM0 EMERGENCY OXYGEN/VENTILATION FAN ENCLOSURE FOR DENTS, CHIPPED OR PEELING PAINT, LOOSE OR MISSING HARDWARE, AND CORROSION.

31.005 2 AT BMA EMERGENCY PASSENGER OXYGEN SYSTEM (EPOS):

A. FOR SECURITY AND NO VISIBLE DAMAGE TO THE EPOS UNIT.

B. HUMIDITY DISK INDICATOR FOR PROPER COLOR (BLUE).

C. FOR CURRENT INSPECTION DATE.

32.002 2 AT BM0 VENTILATION FAN

A. FOR SECURITY AND LOOSE OR MISSING HARDWARE.

B. ELECTRICAL WIRING FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLORATION AND

DETERIORATION), AND CLAMPS FOR SECURITY.

33.001 2 AT BN0 LIGHT ASSEMBLY:

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

5-005 1,2,4 00:39 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

DEPOT

INSPECTION

REQUIREMENTS

A. FOR CRACKED LENS AND SECURITY.

B. ELECTRICAL WIRING FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLORATION AND

DETERIORATION), AND CLAMPS FOR SECURITY.

34.002 2 AT BZ0 SMOKE DETECTOR FOR SECURITY AND LOOSE OR MISSING HARDWARE.

35.001 2 AT BP0 EMERGENCY CALL BUTTON FOR CRACKS AND SECURITY.

36.001 2 AT BK0 TOILET FLUSH HANDLE FOR LOOSE OR MISSING HARDWARE AND CLEANLINESS.

37.001 2 AT BR0 WASH BASIN AND FIXTURES FOR SECURITY, LOOSE OR MISSING HARDWARE, AND CLEANLINESS.

38.020 2 AT BR0 REMOVE, CLEAN, AND INSTALL WASHBASIN DRAINS IN ACCORDANCE WITH TO 13B4-5-1.

39.001 2 AT BT0 MIRROR FOR SECURITY AND CLEANLINESS.

40.001 2 AT BU0 TOWEL AND TOILET PAPER DISPENSERS FOR SECURITY, LOOSE OR MISSING HARDWARE, AND

CLEANLINESS.

41.001 2 AT BR0 SAFETY HANDLE FOR SECURITY AND CLEANLINESS.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

5-005 1,2,4 00:39 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

DEPOT

INSPECTION

REQUIREMENTS

42.001 2 AT BD0 TRASH RECEPTACLE SPRING-HINGE DOOR:

A. FOR PROPER SPRING OPERATION, DENTS, CHIPPED OR PEELING PAINT, LOOSE OR MISSING

HARDWARE, AND CLEANLINESS.

B. STOP FOR SECURITY AND LOOSE OR MISSING RIVETS.

43.002 2 AT BW0 STORAGE COMPARTMENT:

A. HINGE FOR FREEDOM OF OPERATION AND LOOSE OR MISSING RIVETS.

B. LATCH FOR PROPER OPERATION AND LOOSE OR MISSING SCREWS.

C. STOPS FOR CRACKS, DISTORTION, AND LOOSE OR MISSING RIVETS.

D. RUBBER PAD FOR DETERIORATION AND SECURITY.

44.001 2 AT BW0 REMOVE LOWER SHELF IN STORAGE COMPARTMENT IN ACCORDANCE WITH TO 13B4-5-1.

45.001 2 AT BNA TERMINAL BLOCK COVER FOR CRACKS AND LOOSE OR MISSING HARDWARE.

46.001 2 AT BNA TERMINAL BLOCK WIRING HARNESS FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLOR-

ATION AND DETERIORATION), CONNECTIONS FOR SECURITY, AND RACEWAY COVER FOR SECU-

RITY.

47.001 2 AT BN0 LIGHT BALLAST:

A. FOR SECURITY AND LOOSE OR MISSING SCREWS.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

5-006 1,2,4 00:23 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

DEPOT

INSPECTION

REQUIREMENTS

B. WIRING HARNESS FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLORATION AND

DETERIORATION), AND RACEWAY COVER FOR SECURITY.

48.001 2 AT BX0 DC CONVERTER(S):

A. FOR SECURITY AND LOOSE OR MISSING SCREWS.

B. WIRING HARNESS FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLORATION OR

DETERIORATION) AND SECURITY.

49.002 2 AT BW0 INSTALL LOWER SHELF IN STORAGE COMPARTMENT IN ACCORDANCE WITH TO 13B4-5-1.

RIGHT SIDE AREA

50.004 3 AT CA0 WALLS FOR CRACKS, CHIPPED OR PEELING PAINT, DENTS, CORROSION, LOOSE OR MISSING

HARDWARE, AND CLEANLINESS.

51.002 3 AT DB0 ACCESS PANELS FOR DENTS AND LOOSE OR MISSING SCREWS.

52.004 3 AT CC0 FOLD-DOWN STEPS FOR PROPER SPRING OPERATION, CORROSION, AND LOOSE OR MISSING

HARDWARE.

53.001 3 AT CD0 LAVATORY VENT FOR DISTORTION, SECURITY, AND CLEANLINESS.

54.002 3 AT CE0 REFRIGERATOR VENT:

A. FOR DENTS, DISTORTION, LOOSE OR MISSING HARDWARE, AND CLEANLINESS.

B. FAN GUARDS FOR DISTORTION AND LOOSE OR MISSING HARDWARE.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

5-006 1,2,4 00:23 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

DEPOT

INSPECTION

REQUIREMENTS

55.002 3 AT CF0 STORAGE COMPARTMENT:

A. HINGE FOR FREEDOM OF OPERATION AND LOOSE OR MISSING RIVETS.

B. DOOR LATCH FOR PROPER OPERATION AND LOOSE OR MISSING SCREWS.

C. DOORSTOP FOR CRACKS, DISTORTION, AND LOOSE OR MISSING RIVETS.

D. RUBBER PAD FOR DETERIORATION AND SECURITY.

56.002 3 AT CG0 CATWALK:

A. FOR DENTS, CHIPPED OR PEELING PAINT, LOOSE OR MISSING HARDWARE, AND CLEANLINESS.

B. RUBBER FLOORING FOR RIPS, TEARS, AND SECURITY.

C. CATWALK EXTENSION BRACKETS AND PLATES FOR CHIPPED OR PEELING PAINT, LOOSE OR

MISSING HARDWARE, AND SECURITY.

57.002 3 AT CG0 CATWALK EXTENSION:

A. FOR DENTS, DISTORTION, CHIPPED OR PEELING PAINT, AND LOOSE OR MISSING RIVETS.

B. RUBBER FLOORING FOR RIPS, TEARS, AND SECURITY.

C. SUPPORT BRACKET FOR LOOSE OR MISSING HARDWARE, AND SECURITY.

D. VELCRO® STRAPS FOR RIPS, TEARS, DETERIORATION, AND SECURITY.

E. HINGE FOR LOOSE OR MISSING RIVETS.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

5-007 1,2,4 00:14 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

DEPOT

INSPECTION

REQUIREMENTS

58.002 3 AT CH0 TARP STORAGE COVER:

A. FOR RIPS, TEARS, AND FRAYING.

B. FABRIC FOR WATERPROOFING.

C. VELCRO® STRAPS FOR RIPS, TEARS, DETERIORATION, AND SECURITY.

LEFT SIDE AREA

59.004 4 AT DA0 WALLS FOR CRACKS, CHIPPED OR PEELING PAINT, DENTS, CORROSION, LOOSE OR MISSING

HARDWARE, AND CLEANLINESS.

60.002 4 AT DB0 STORAGE COMPARTMENT:

A. HINGE FOR FREEDOM OF OPERATION AND LOOSE OR MISSING RIVETS.

B. DOOR LATCH FOR PROPER OPERATION AND LOOSE OR MISSING SCREWS.

C. DOORSTOP FOR CRACKS, DISTORTION, AND LOOSE OR MISSING RIVETS.

D. RUBBER PAD FOR DETERIORATION AND SECURITY.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

5-007 1,2,4 00:14 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE

DEPOT

INSPECTION

REQUIREMENTS

61.003 4 AT DC0 CABLE RESTRAINT:

A. FOR CRACKS, DENTS, CHIPPED OR PEELING PAINT, AND LOOSE OR MISSING HARDWARE.

B. STORAGE PINS FOR SECURITY AND LOOSE OR MISSING HARDWARE.

C. CABLE CLAMPS FOR SECURITY AND LOOSE OR MISSING HARDWARE.

D. MOUNTING BRACKETS FOR CRACKS, DENTS, CHIPPED OR PEELING PAINT, AND SECURITY.

62.003 4 AT DD0 POWER RECEPTACLE PANEL:

A. FOR SECURITY AND LOOSE OR MISSING RIVETS.

B. CONNECTORS FOR EVIDENCE OF OVERHEATING, BENT PINS, SECURITY, AND LOOSE OR

MISSING HARDWARE.

C. GROUNDING LUG FOR SECURITY, CORROSION, AND LOOSE OR MISSING HARDWARE.

D. NAMEPLATES FOR DISTORTION AND LOOSE OR MISSING RIVETS.

63.002 4 AT DF0 REFRIGERATOR VENT FOR DENTS, DISTORTION, LOOSE OR MISSING HARDWARE, AND CLEANLI-

NESS.

64.001 4 AT DE0 LAVATORY VENT FOR DISTORTION, SECURITY, AND CLEANLINESS.

65.003 4 AT DG0 HUMAN WASTE TANK DRAIN HOSE:

A. FOR CUTS, CRACKS, DETERIORATION, AND EVIDENCE OF LEAKAGE.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

5-008 1,2,4 00:23 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE INSPECTION

REQUIREMENTS

B. CLAMPS FOR SECURITY.

C. STORAGE BRACKETS FOR CRACKS, CHIPPED OR PEELING PAINT, AND LOOSE OR MISSING

HARDWARE.

66.002 4 AT DI0 HUMAN WASTE TANK VENT HOSE:

A. FOR CUTS, CRACKS, DETERIORATION, AND EVIDENCE OF LEAKAGE.

B. STORAGE BRACKETS FOR CRACKS, CHIPPED OR PEELING PAINT, AND LOOSE OR MISSING

HARDWARE.

67.001 4 AT DJ0 PRE-CHARGE AND FULL LIGHT LENSES FOR CRACKS AND SECURITY.

68.002 4 AT DK0 ELECTRICAL POWER CABLE:

A. WIRING HARNESS FOR EVIDENCE OF OVERHEATING (INSULATION DISCOLORATION AND

DETERIORATION).

B. CONNECTORS FOR EVIDENCE OF OVERHEATING, BENT PINS, SECURITY, AND LOOSE OR

MISSING HARDWARE.

TOP AREA

69.004 6 AT EA0 SURFACE FOR CRACKS, CHIPPED OR PEELING PAINT, DENTS, CORROSION, LOOSE OR MISSING

HARDWARE, AND CLEANLINESS.

70.001 6 AT EB0 HAND SUPPORT FOR DENTS AND LOOSE OR MISSING SCREWS.

71.001 6 AT EC0 BAGGAGE TIE-DOWN TRACK FOR LOOSE OR MISSING SCREWS.

CUI

CARD NO WORK AREA(S) TYPE MECH RQR MECH NO CARD TIME PUBLICATION NUMBER CHANGE NO

5-008 1,2,4 00:23 TO 13B4-5-6WC-1 0

MIN WORK

AREA

WORK UNIT CODE INSPECTION

REQUIREMENTS

72.002 6 AT ED0 POTABLE WATER TANK ACCESS PANEL AND CAP FOR SECURITY.

BOTTOM AREA

73.020 5 AT FA0 REMOVE 463L CARGO PALLET.

74.020 5 AT FA0 463L CARGO PALLET FOR CORROSION AND LOOSE OR MISSING HARDWARE.

75.010 5 AT 000 BOTTOM OF AIR TRANSPORTABLE GALLEY/LAVATORY (ATGL) AND…