Question and Answer 6.docx

DOCX document 13 KB Posted

Attached to
Ground Power Modernization Federal contract opportunity
Solicitation number
FA8532-22-R-0001
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Robins Air Force Base

About this file

This document provides details on an anticipated federal contract opportunity for ground power equipment. The Air Force Materiel Command Lifecycle Management Center at Robins Air Force Base plans to issue a request for proposal for indefinite-delivery, indefinite-quantity multiple award contracts. The contracts will include requirements for 72kW ground power units, 144kW ground power units, and 144kW universal load banks to provide power to various Air Force aircraft. The total estimated quantities are 2928 units for the 72kW GPUs, 250 units for the 144kW GPUs, and 300 units for the 144kW ULBs. One group of contracts will consolidate all three end items on a full and open basis, while a separate small business set-aside contract will be for the 72kW GPUs only. The contracts will have a basic three-year period and seven one-year ordering periods, with an anticipated release of the RFP on October 15, 2021 and award date of September 26, 2022.

View the file

Other files for this federal contract opportunity

Other files attached to Ground Power Modernization, newest first.
File Type Posted
Question and Answer 8.docx DOCX document
RFP Attachment 3 - List of Fill-In Clauses to be Completed - Revised 2.pdf PDF
FA8532-22-R-0001_0003.pdf PDF
FA8532-22-R-0001_0002.pdf PDF
Question and Answer 3.docx DOCX document
FA8532-22-R-0001_0001.pdf PDF
RFP Attachment 10 - Price Spreadsheet - Revised.xlsx XLSX spreadsheet
Question and Answer 2.docx DOCX document
Question and Answer 1.docx DOCX document
RFP Attachment 10 - Price Spreadsheet.xlsx XLSX spreadsheet
RFP Attachment 6 - Subcontractor and Teaming Member Consent Form.pdf PDF
RFP Attachment 3 - List of Fill-In Clauses to be Completed.pdf PDF
E005.pdf PDF
E004.pdf PDF
E008.pdf PDF
F002.pdf PDF
C005.pdf PDF
C002.pdf PDF
A003.pdf PDF
C017.pdf PDF
Engineering Data Lists.pdf PDF
D004.pdf PDF
Statement of Work (SOW)_1 Sep 21.pdf PDF
L-900 Instructions to Offerors.pdf PDF
Ground Power Modernization Ordering Guide.pdf PDF
RFP Attachment 9 - GPU Engine Derating Calculation Worksheet.pdf PDF
D003_TM86-01R.pdf PDF
D004_TM86-01R.pdf PDF
E009.pdf PDF
D001.pdf PDF
C009.pdf PDF
C007.pdf PDF
F001.pdf PDF
E001.pdf PDF
C001.pdf PDF
B002.pdf PDF
A002.pdf PDF
C015.pdf PDF
200415485_98752_EDL.pdf PDF
RFP Attachment 5 - Relevancy Table.pdf PDF
Warranty Tracking Information.pdf PDF
Source of Repair Instructions.pdf PDF
C016.pdf PDF
C014.pdf PDF
D005.pdf PDF
C006.pdf PDF
F003.pdf PDF
E007.pdf PDF
D002.pdf PDF
C013.pdf PDF
Show all 50

Ground Power Modernization has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Solicitation Questions and Answers #6 9 Nov 2021

Q1:Section 3.9.3 specifies that SAE AS8090 shall be the governing document for the design of thechassis, unless otherwise specified. Per AS8090 requirements for Type 2 Class C, table 3indicates that this type of system is to have service brakes of either Air, Air over hydraulic, orinertia activated mechanical or hydraulic brakes on all four wheels. This is further reinforced bythe ASM A8090 referencing Federal Motor Vehicle Safety Standards (FMVSS 393.40, 41, 42, 52)which further indicate the need for 4 wheel service brakes. However, in section 3.9.3.6 of the72Kw Purchase Description it specifically states “Surge type, hydraulic type, or automaticallyapplied parking brakes are prohibited.” Section 3.9.3.6 also limits the parking brakes to “boththe right and left wheel positions of the rear axle in accordance with 3.6.1 of SAE AS8090.The purchase description does not make any mention of 4 wheel service brakes. The question is,is a 4 wheel service brake system required on this system, or is the two wheel leaver operatedparking brake sufficient to conform with the specification of the 72kW GPU?
A1:PD21WRWNZEA008 paragraph 3.9.3 states “All other requirements and specifications containedwith SAE AS8090 as applicable to Type II, Group C towed aerospace ground equipment shall bein full force and effect unless stated otherwise herein.” Therefore, PD21WRWNZEA008paragraph 3.9.3 requires the 72 kW/90 kVA GPU to meet the requirements of SAE AS8090 forType II, Group C equipment unless PD21WRWNZEA008 explicitly states otherwise. Note thatTable III and Table IV of SAE AS8090 list requirements for multiple types of towed aerospaceground equipment. Within SAE AS8090, the requirements for mandatory four wheel braking, ofeither parking or service type do not align with the rows and columns detailing Type II, Group Cperformance; therefore, SAE AS8090 does not define a mandatory four wheel brakingrequirement for Type II, Group C equipment and neither does PD21WRWNZEA008.
PD21WRWNZEA008 paragraph 3.9.6.3 is the governing requirement for brakes on the 72 kW/90kVA GPU. There is no mandatory requirement for four wheel parking brakes; the minimumrequirement for parking brakes is found in PD21WRWNZEA008 paragraph 3.9.6.3. The maximumtow speed and GVW of the 72 kW/90 kVA GPU should not justify the use of four wheel parkingbrakes to remain stationary under the conditions required within PD21WRWNZEA008; however,in accordance with SAE AS8090, the contractor shall perform their own braking analysis basedupon the selected components for final determination of parking brakes on the front axle. It isnoted the Government prefers properly sized parking brakes be fitted to the rear axle only asspecified in PD21WRWNZEA008 paragraph 3.9.6.3.
There is no explicit requirement for service brakes of any type contained withinPD21WRWNZEA008. PD21WRWNZEA008 paragraph 3.9.6.3 is the governing requirement forbrakes on the 72 kW/90 kVA GPU and this paragraph only requires parking brakes. As such,there is no PD21WRWNZEA008 mandatory requirement for service brakes; service brakes arenot required nor are they desired. The maximum tow speed and GVW of the 72 kW/90 kVA GPUdo not justify the use of service brakes to maintain braking stability under the operationalconditions required within PD21WRWNZEA008.
The Government will take action to modify PD21WRWNZEA008 to clearly delineate that servicebrakes are not to be installed on the 72 kW/90 kVA GPU.