This is an equipment list spreadsheet documenting the complete inventory and configuration of the Building 228 Access Control and CCTV system at Robins Air Force Base, Georgia. The system comprises two Lenel UnitedTechnologies ACC servers (DISAWRSEC1 and DISAWRSEC2) configured for redundancy with a failover architecture, one LNVR video server (DISAWRVID1), and four workstations positioned throughout the facility (Main Security Office, Chuck's Office, and Server Room). The software platform is Lenel OnGuard version 7.0.1067.0 with 64 reader licenses deployed on the primary server.

The physical security infrastructure includes 38 access control readers (HID brand card readers for entry and exit points) integrated with two LNL-2220 controllers and 32 LNL-1320 interface modules, managing access to 42 monitored and controlled doors throughout the building. Video surveillance comprises 38 IP cameras (primarily Axis P3365-V and P3365-VE models) operating at 1920x1080 resolution and 9 fps, connected through two network switches (SW-01 and SW-02). The intrusion detection system uses Honeywell Vista 128BP and 4208U panels monitoring 16 perimeter zones with door contact sensors. Notable system issues documented include non-functional door contacts at multiple locations, incomplete door installations due to ongoing base construction, malfunctioning emergency exit buttons and pull stations at various access points, and a specialized 12-volt maglock installation at the Computer Mechanical Room that required post-installation adaptation. All system credentials, IP addresses, MAC addresses, and serial numbers are detailed for each device.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Licenses

License Documentation
License TypeDescription# 0f LicensesLicense KeyServerTotal On Server
LenelReader License64DISAWRSEC164
LenelReader License64DISAWRSEC2
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

Servers

Server Documentation
Unit NameDescriptionModelSerial #IP AddressMAC AddressNetwork SwitchPort #LoginPasswordStatusNotes
DISAWRSEC1ACC Server - 1BCD360V8-M-MP-C135567-ACSMXQ50200WL10.20.100.25114-58-D0-5F-42-ECSW-02-Convergintatlanta.401Fully OperationalContains Database (Login = SA Password = WRs@sec21
DISAWRSEC2ACC Server - 2 (Failover)BCD360V8-M-MP-C135567-ACSMXQ50200WV10.20.100.25214-58-D0-5F-82-63SW-02-Convergintatlanta.401Fully OperationalContains Database (Login = SA Password = WRs@sec21
DISAWRVID1LNVR ServerBCD380V8-M-VRP-C-135567-RS1USE443DD4210.20.100.254C4-34-6B-B6-7C-1CSW-02-Convergintatlanta.401Fully Operational

Workstations

Workstation Documentation
Unit NameModelLoginPasswordSerial NumberIP AddressMAC AddressNetwork SwitchPort NumberStatusNotes
DISAWRMON1BCD230S-M-CWS-135567-WS1Convergintatlanta.4012UA5050YX310.20.100.2164-51-06-3D-AF-16SW-0217Updated and ready for InstallationMain Security Office - Big Room (184)
DISAWRMON2BCD230S-M-CWS-135567-WS1Convergintatlanta.4012UA5050YX810.20.100.2264-51-06-3D-AF-1ESW-0222Updated and ready for InstallationMain Security Office - Small Room (169)
DISAWRMON3BCD230S-M-CWS-135567-WS1Convergintatlanta.4012UA5050YX210.20.100.2364-51-06-48-49-7BSW-032Updated and ready for InstallationMain Security Office - Chuck's Office (170)
DISAWRMON4BCD230S-M-CWS-135567-WS1Convergintatlanta.4012UA5050YX910.20.100.2464-51-06-48-45-EDSW-031Updated and ready for InstallationServer Room Man Trap (129)

Cameras

Camera Documentation
Description/LocationMakeModelIP/AnalogEncoderEncoder PortIP AddressMAC AddressS/NComp/QualityImage RateResolutionNetwork SwitchPortLoginPasswordServerStatusNotes
C01 - FRONT DOOR PTZAxisQ6035-EIP--10.20.100.101AC-CC-8E-1F-EF-70ACCC8E1FEF70409 fps1280X720SW011rootpassDISAWRVID1
C02 - RM 181 NW EXITAxisP3365-VIP--10.20.100.102AC-CC-8E-1E-3B-93ACCC8E1E3B93409 fps1920X1080SW012rootpassDISAWRVID1Focused
C03 - COMP ADMIN ROOM ENTAxisP3365-VIP--10.20.100.103AC-CC-8E-1E-3B-BDACCC8E1E3BBD409 fps1920X1080SW013rootpassDISAWRVID1Focused
C04 - COMP ADMIN ROOM EXITAxisP3365-VIP--10.20.100.104AC-CC-8E-1E-3B-6BACCC8E1E3B6B409 fps1920X1080SW014rootpassDISAWRVID1Focused
C05 - COMP MECH ROOM ENTAxisP3365-VIP--10.20.100.105AC-CC-8E-1E-3B-BCACCC8E1E3BBC409 fps1920X1080SW015rootpassDISAWRVID1Focused
C06 - ROOM 181 SW EXITAxisP3365-VEIP--10.20.100.106AC-CC-8E-31-26-FEACCC8E3126FE409 fps1920X1080SW016rootpassDISAWRVID1Focused
C07 - MECH ROOMAxisP3365-VIP--10.20.100.107AC-CC-8E-1E-3B-95ACCC8E1E3B95409 fps1920X1080SW017rootpassDISAWRVID1Focused
C08 - COMM ROOM EXITAxisP3365-VIP--10.20.100.108AC-CC-8E-1E-3B-96ACCC8E1E3B96409 fps1920X1080SW018rootpassDISAWRVID1Focused
C09 - COMM ROOM ENTAxisP3365-VIP--10.20.100.109AC-CC-8E-1E-3B-BBACCC8E1E3BBB409 fps1920X1080SW019rootpassDISAWRVID1Focused
C10 - COMP MECH ROOM EXITAxisP3365-VIP--10.20.100.110AC-CC-8E-1E-3B-94ACCC8E1E3B94409 fps1920X1080SW0110rootpassDISAWRVID1Focused
C11 - COMP ROOM REAR EXITAxisP3365-VIP--10.20.100.111AC-CC-8E-1D-E8-05ACCC8E1DE805409 fps1920X1080SW0111rootpassDISAWRVID1Focused
C12 - CDC SECURE ROOM ENTAxisP3365-VIP--10.20.100.112AC-CC-8E-1D-E9-4EACCC8E1DE94E409 fps1920X1080SW0112rootpassDISAWRVID1Focused
C13 - COMP SMC EXITAxisP3365-VIP--10.20.100.113AC-CC-8E-1D-E7-96ACCC8E1DE796409 fps1920X1080SW0113rootpassDISAWRVID1Focused
C14 - COMP SECURITY EXITAxisP3365-VIP--10.20.100.114AC-CC-8E-1D-E8-07ACCC8E1DE807409 fps1920X1080SW0114rootpassDISAWRVID1Focused
C15 - SECURITY EXITAxisP3365-VIP--10.20.100.115AC-CC-8E-1D-E8-4FACCC8E1DE84F409 fps1920X1080SW0115rootpassDISAWRVID1Focused
C16 - SECURITY ENTAxisP3365-VIP--10.20.100.116AC-CC-8E-1D-E9-84ACCC8E1DE984409 fps1920X1080SW0116rootpassDISAWRVID1Focused
C17 - COMP SMC ENTAxisP3365-VIP--10.20.100.117AC-CC-8E-1D-E8-50ACCC8E1DE850409 fps1920X1080SW0117rootpassDISAWRVID1Focused
C18 - COMP BATTERY ROOM EXITAxisP3365-VIP--10.20.100.118AC-CC-8E-1D-E9-85ACCC8E1DE985409 fps1920X1080SW0118rootpassDISAWRVID1Focused
C19 - MECH COMPOUND GENERATORAxisP3365-VEIP--10.20.100.119AC-CC-8E-1E-3D-94ACCC8E1E3D94409 fps1920X1080SW0119rootpassDISAWRVID1Focused
C20 - REAR GATEAxisP3365-VEIP--10.20.100.120AC-CC-8E-31-27-00ACCC8E312700409 fps1920X1080SW0120rootpassDISAWRVID1Focused
C21 - SE ENTRANCE ENTAxisP3365-VIP--10.20.100.121AC-CC-8E-1D-E8-4DACCC8E1DE84D409 fps1920X1080SW0220rootpassDISAWRVID1Focused
C22 - COMP ROOM REAR ENTAxisP3365-VIP--10.20.100.122AC-CC-8E-1D-E8-04ACCC8E1DE804409 fps1920X1080SW0122rootpassDISAWRVID1Focused
C23 - NORTH SMC EMERG DOOR ENTAxisP3365-VIP--10.20.100.123AC-CC-8E-1D-E8-4CACCC8E1DE84C409 fps1920X1080SW0123rootpassDISAWRVID1Focused
C24 - SOUTH SMC EMERG DOOR EXITAxisP3365-VIP--10.20.100.124AC-CC-8E-1D-E8-4BACCC8E1DE84B409 fps1920X1080SW0124rootpassDISAWRVID1Focused
C25 - SOUTH SMC EMERG DOOR ENTAxisP3365-VIP--10.20.100.125AC-CC-8E-1D-E8-03ACCC8E1DE803409 fps1920X1080SW021rootpassDISAWRVID1Focused
C26 - COMPUTER RM 177B ENTAxisP3365-VIP--10.20.100.126AC-CC-8E-1E-3B-77ACCC8E1E3B77409 fps1920X1080SW022rootpassDISAWRVID1Focused
C27 - NORTH SMC EMERG DOOR ENTAxisP3365-VIP--10.20.100.127AC-CC-8E-1E-3B-C5ACCC8E1E3BC5409 fps1920X1080SW023rootpassDISAWRVID1Focused
C28 - NORTH SMC EMERG DOOR EXITAxisP3365-VIP--10.20.100.128AC-CC-8E-1E-3B-75ACCC8E1E3B75409 fps1920X1080SW024rootpassDISAWRVID1Focused
C29 - SMC EXITAxisP3365-VIP--10.20.100.129AC-CC-8E-1E-3B-78ACCC8E1E3B78409 fps1920X1080SW025rootpassDISAWRVID1Focused
C30 - SMC ENTAxisP3365-VIP--10.20.100.130AC-CC-8E-1E-3B-76ACCC8E1E3B76409 fps1920X1080SW026rootpassDISAWRVID1Focused
C31 - COMPUTER RM 177A ENTAxisP3365-VIP--10.20.100.131AC-CC-8E-1E-3B-9BACCC8E1E3B9B409 fps1920X1080SW027rootpassDISAWRVID1Focused
C32 - BACK ENTRANCE NE ENTAxisP3365-VEIP--10.20.100.132AC-CC-8E-31-26-EEACCC8E3126EE409 fps1920X1080SW028rootpassDISAWRVID1Focused
C33 - COMPUTER RM 177A EXITAxisP3365-VIP--10.20.100.133AC-CC-8E-1E-3B-C8ACCC8E1E3BC8409 fps1920X1080SW029rootpassDISAWRVID1
C34 - SUPPLY ROOMAxisP3365-VIP--10.20.100.134AC-CC-8E-1E-3B-C7ACCC8E1E3BC7409 fps1920X1080SW0210rootpassDISAWRVID1Focused
C35 - COMPUTER ROOM 177C EXITAxisP3365-VIP--10.20.100.135AC-CC-8E-1E-3B-74ACCC8E1E3B74409 fps1920X1080SW0211rootpassDISAWRVID1Focused
C36 - COMPUTER RM 177C EXITAxisP3365-VIP--10.20.100.136AC-CC-8E-1E-3B-C6ACCC8E1E3BC6409 fps1920X1080SW0212rootpassDISAWRVID1Focused
C37 - OUTISDE ENTRANCE RM 178 ENTAxisP3365-VEIP--10.20.100.137AC-CC-8E-31-26-ECACCC8E3126EC409 fps1920X1080SW0213rootpassDISAWRVID1
C38 - LOADING DOCKAxisP3365-VEIP--10.20.100.138AC-CC-8E-31-26-EDACCC8E3126ED409 fps1920X1080SW0214rootpassDISAWRVID1

Encoders

Encoder Documentation
Description/LocationMakeModel# of ChannelsIP AddressMAC AddressS/NNetwork SwitchPortLicenses UsedStatusNotes

NVR's

DVR Documentation
Unit NameModelSerial #IP AddressMAC AddressNetwork SwitchPort #StatusNotes

ACC Panels

ACC Panel Documentation
Panel #Panel DescriptionPanel TypePanel LocationControlling PanelPanel IPPanel MACSerial #AddressControl PortNetwork SwitchSwitch PortLoginPasswordStatusNotes
1Controller 1LNL-2220ACP-1DISAWR - 2220 - 110.20.100.5100-0F-E5-03-56-93606327--SW-0223Convergintctc.401Working
2Interface 2LNL-1320ACP-1Controller 1---02----Working
3Interface 3LNL-1320ACP-1Controller 1---12----Working
4Interface 4LNL-1320ACP-1Controller 1---22----Working
5Interface 5LNL-1320ACP-1Controller 1---32----Working
6Interface 6LNL-1320ACP-1Controller 1---42----Working
7Interface 7LNL-1320ACP-1Controller 1---52----Working
8Interface 8LNL-1320ACP-1Controller 1---62----Working
9Interface 9LNL-1320ACP-2Controller 1---72----Working
10Interface 10LNL-1320ACP-2Controller 1---82----Working
11Interface 11LNL-1320ACP-2Controller 1---92----Working
12Interface 12LNL-1320ACP-2Controller 1---102----Working
13Interface 13LNL-1320ACP-2Controller 1---112----Working
14Interface 14LNL-1320ACP-2Controller 1---122----Working
15Interface 15LNL-1320ACP-2Controller 1---132----Working
16Interface 16LNL-1320ACP-2Controller 1---142----Working
17Interface 17LNL-1320ACP-3Controller 1---152----Working
18Interface 18LNL-1320ACP-3Controller 1---162----Working
19Interface 19LNL-1320ACP-3Controller 1---172----Working
20Interface 20LNL-1320ACP-3Controller 1---182----Working
21Interface 21LNL-1320ACP-3Controller 1---192----Working
22Interface 22LNL-1320ACP-3Controller 1---202----Working
23Interface 23LNL-1320ACP-3Controller 1---212----Working
24Interface 24LNL-1320ACP-3Controller 1---222----Working
25Interface 25LNL-1320ACP-4Controller 1---232----Working
26Interface 26LNL-1320ACP-4Controller 1---242----Working
27Interface 27LNL-1320ACP-4Controller 1---252----Working
28Interface 28LNL-1320ACP-4Controller 1---262----Working
29Interface 29LNL-1320ACP-4Controller 1---272----Working
30Interface 30LNL-1320ACP-4Controller 1---282----Working
31Interface 31LNL-1320ACP-4Controller 1---292----Working
32Interface 32LNL-1320ACP-4Controller 1---302----Working
33Controller 2LNL-2220ACP-5DISAWR - 2220 - 210.20.100.5200-0F-E5-C3-7B-61609986--SW-0224Convergintctc.401Working
34Interface 2LNL-1320ACP-5Controller 2---02----Working
35Interface 3LNL-1320ACP-5Controller 2---12----Working
36Interface 4LNL-1320ACP-5Controller 2---22----Working
37Interface 5LNL-1320ACP-5Controller 2---32----Working
38Input 1LNL-1100ACP-5Controller 2---42----Working
39Output 1LNL-1200ACP-5Controller 2---52----Working

Readers

Reader Documentation
Reader #DescriptionModelSerial #Control PanelInterface PanelInput #StatusNotes
101 - Main Entrance #1 ENT

Matt Cherry: Matt Cherry:

Notes:

Existing Emergency Exit button previously installed on door has been hooked up to the RQE input and programmed to trip the door ouput. There is no siren or intrusion command sent out if pressed.HID6136CKN000709G30DISAWR - 2220 - 1DISAWR - 2220 - 10WorkingEmergency Exit Button Attached to new System
101 - Main Entrance #1 EXIT

Matt Cherry: Matt Cherry:

Notes:

Existing Emergency Exit button previously installed on door has been hooked up to the RQE input and programmed to trip the door ouput. There is no siren or intrusion command sent out if pressed.HID6125CGN0007G30LDISAWR - 2220 - 1DISAWR - 2220 - 11Working
202 - Admin Front ENT

Matt Cherry: Matt Cherry:

Notes:

Existing Emergency Exit pull station installed on door has been attached in line of the 24v power supply to kill power in the event it is tripped. There is no siren or intrusion command sent out if pressed.HID6136CKN000709G30DISAWR - 2220 - 1Interface 20WorkingEmergency Pull Station Attached
202 - Admin Front EXIT

Matt Cherry: Matt Cherry:

Notes:

Existing Emergency Exit pull station installed on door has been attached in line of the 24v power supply to kill power in the event it is tripped. There is no siren or intrusion command sent out if pressed.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 21WorkingEmergency Pull Station Attached
303 - Main Entrance #2 ENT

Matt Cherry: Matt Cherry:

The door did not have an existing door contact. As it was not part of the scope to install new door contacts, it is still without one now.

There was an existing button on this door that has been removed.HID6136CKN000709G30DISAWR - 2220 - 1Interface 30WorkingNo Contact on Door
303 - Main Entrance #2 EXIT

Matt Cherry: Matt Cherry:

The door did not have an existing door contact. As it was not part of the scope to install new door contacts, it is still without one now.

There was an existing button on this door that has been removed.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 31WorkingNo Contact on Door
404 - Room 181 NW ENT

Matt Cherry: Matt Cherry:

HID6136CKN000709G30DISAWR - 2220 - 1Interface 40Working
404 - Room 181 NW EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 41Working
505 - Admin Rear ENT

Matt Cherry: Matt Cherry:

The existing exit button has been removed from this door.

The door contact that was in place during the time of installation was broken. As it was not part of the scope of our work to install new door contacts it is still without one after our installation is complete.HID6136CKN000709G30DISAWR - 2220 - 1Interface 50WorkingBad Contact
505 - Admin Rear EXIT

Matt Cherry: Matt Cherry:

Matt Cherry:

Notes:

The existing exit button has been removed from this door.

The door contact that was in place during the time of installation was broken. As it was not part of the scope of our work to install new door contacts it is still without one after our installation is complete.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 51WorkingBad Contact
606 - Comp Admin Room ENT

Matt Cherry: Matt Cherry:

HID6136CKN000709G30DISAWR - 2220 - 1Interface 60Working
606 - Comp Admin Room EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 61Working
707 - NS ENT

Matt Cherry: Matt Cherry:

Room that this door enters into at one point had it’s own "SCIF" like local security system. It was disabled before we arrived.HID6136CKN000709G30DISAWR - 2220 - 1Interface 70Working
707 - NS EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 71Working
808 - NS Back ENT

Matt Cherry: Matt Cherry:

Room that this door enters into at one point had it’s own "SCIF" like local security system. It was disabled before we arrived.HID6136CKN000709G30DISAWR - 2220 - 1Interface 80Working
808 - NS Back EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 81Working
909 - Comp Mech Room ENT

Matt Cherry: Matt Cherry:

This door has the only 12V only maglock in the entire building. As this was not understood when the initial wiring was put in, it has been adapted after the fact. Currently the 12V power is coming from the 12V distributor in the lower power supply and is triggered via the ground line going through the output relay on the 1320.HID6136CKN000709G30DISAWR - 2220 - 1Interface 90Working12V Maglock
909 - Comp Mech Room EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 91Working12V Maglock
1010 - Mechanical Room Main ENT

Matt Cherry: Matt Cherry:

HID6136CKN000709G30DISAWR - 2220 - 1Interface 100Working
1010 - Mechanical Room Main EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 101Working
1111 - Room 181 SW ENT

Matt Cherry: Matt Cherry:

The door contact on this door is a high security contact and as such is very sensistive. When the contact was installed the door was having some trouble closing and didn’t always show a "normal" state.

The door will need to be adjusted to repair the issue.HID6136CKN000709G30DISAWR - 2220 - 1Interface 110WorkingDoor Problems
1111 - Room 181 SW EXIT

Matt Cherry: Matt Cherry:

The door contact on this door is a high security contact and as such is very sensistive. When the contact was installed the door was having some trouble closing and didn’t always show a "normal" state.

The door will need to be adjusted to repair the issue.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 111WorkingDoor Problems
1212 - Gazebo Gate ENT

Matt Cherry: Matt Cherry:

HID6136CKN000709G30DISAWR - 2220 - 1Interface 120Working
1212 - Gazebo Gate EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 121Working
1313 - Mechanical Room Compound ENT

Matt Cherry: Matt Cherry:

Notes:

Existing Emergency Exit pull station installed on door has been attached in line of the 24v power supply to kill power in the event it is tripped. There is no siren or intrusion command sent out if pressed.

HID6136CKN000709G30DISAWR - 2220 - 1Interface 130WorkingEmergency Pull Station Attached
1313 - Mechanical Room Compound EXIT

Matt Cherry: Matt Cherry:

Notes:

Existing Emergency Exit pull station installed on door has been attached in line of the 24v power supply to kill power in the event it is tripped. There is no siren or intrusion command sent out if pressed.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 131WorkingEmergency Pull Station Attached
1414 - Comm Room ENT

Matt Cherry: Matt Cherry:

Notes:

The existing Door Contact is malfunctioning and will not report back properly. As the scope of our work does not inlcude repairing existing contacts or installing a new one on this door it was left inoperable.

Existing Emergency Exit pull station installed on door has been attached in line of the 24v power supply to kill power in the event it is tripped. There is no siren or intrusion command sent out if pressed.HID6136CKN000709G30DISAWR - 2220 - 1Interface 140WorkingBad Contact/ Emergency Pull Station Attached
1414 - Comm Room EXIT

Matt Cherry: Matt Cherry:

Notes:

The existing Door Contact is malfunctioning and will not report back properly. As the scope of our work does not inlcude repairing existing contacts or installing a new one on this door it was left inoperable.

Existing Emergency Exit pull station installed on door has been attached in line of the 24v power supply to kill power in the event it is tripped. There is no siren or intrusion command sent out if pressed.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 141WorkingBad Contact/ Emergency Pull Station Attached
1515 - UPS Room ENT

Matt Cherry: Matt Cherry:

Notes:

Existing Emergency Exit pull station installed on door has been attached in line of the 24v power supply to kill power in the event it is tripped. There is no siren or intrusion command sent out if pressed.HID6136CKN000709G30DISAWR - 2220 - 1Interface 150WorkingEmergency Pull Station Attached
1515 - UPS Room EXIT

Matt Cherry: Matt Cherry:

Notes:

Existing Emergency Exit pull station installed on door has been attached in line of the 24v power supply to kill power in the event it is tripped. There is no siren or intrusion command sent out if pressed.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 151WorkingEmergency Pull Station Attached
1616 - Compound Pedestrian Gate ENT

Matt Cherry: Matt Cherry:

HID6136CKN000709G30DISAWR - 2220 - 1Interface 160Working
1616 - Compound Pedestrian Gate EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 161Working
1717 - Comp Battery Room ENT

Matt Cherry: Matt Cherry:

HID6136CKN000709G30DISAWR - 2220 - 1Interface 170Working
1717 - Comp Battery Room EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 171Working
1818 - Comp Room Rear ENT

The existing Door Contact is malfunctioning and will not report back properly. As the scope of our work does not inlcude repairing existing contacts or installing a new one on this door it was left inoperable.

HID6136CKN000709G30DISAWR - 2220 - 1Interface 180WorkingBad Contact
1818 - Comp Room Rear EXIT
The existing Door Contact is malfunctioning and will not report back properly. As the scope of our work does not inlcude repairing existing contacts or installing a new one on this door it was left inoperable.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 181WorkingBad Contact
1919 - Comp SMC ENT

Matt Cherry: Matt Cherry:

Notes:

Existing Emergency Exit Button was attached to the new system via the Aux Input 1. It is programmed to open the door and fire off a local siren for 30 seconds.

The local siren is on AUX Output 2.HID6136CKN000709G30DISAWR - 2220 - 1Interface 190WorkingEmergency Exit Button Attached to new System
1919 - Comp SMC EXIT

Matt Cherry: Matt Cherry:

Notes:

Existing Emergency Exit Button was attached to the new system via the Aux Input 1. It is programmed to open the door and fire off a local siren for 30 seconds.

The local siren is on AUX Output 2.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 191WorkingEmergency Exit Button Attached to new System
2020 - Comp Security ENT

Matt Cherry: Matt Cherry:

Notes:

Existing Emergency Exit Button was attached to the new system via the Aux Input 1. It is programmed to open the door and fire off a local siren for 30 seconds.

The local siren is on AUX Output 2.HID6136CKN000709G30DISAWR - 2220 - 1Interface 200WorkingEmergency Exit Button Attached to new System
2020 - Comp Security EXIT

Matt Cherry: Matt Cherry:

Notes:

Existing Emergency Exit Button was attached to the new system via the Aux Input 1. It is programmed to open the door and fire off a local siren for 30 seconds.

The local siren is on AUX Output 2.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 201WorkingEmergency Exit Button Attached to new System
2121 - Security ENT

The existing Door Contact is malfunctioning and will not report back properly. As the scope of our work does not inlcude repairing existing contacts or installing a new one on this door it was left inoperable.

Existing Emergency Exit Button was attached to the new system via the Aux Input 1. It is programmed to open the door and fire off a local siren for 30 seconds.

The local siren is on AUX Output 2.HID6136CKN000709G30DISAWR - 2220 - 1Interface 210WorkingBad Contact / Emergency Exit Button Attached to new System
2121 - Security EXIT

The existing Door Contact is malfunctioning and will not report back properly. As the scope of our work does not inlcude repairing existing contacts or installing a new one on this door it was left inoperable.

Existing Emergency Exit Button was attached to the new system via the Aux Input 1. It is programmed to open the door and fire off a local siren for 30 seconds.

The local siren is on AUX Output 2.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 211WorkingBad Contact / Emergency Exit Button Attached to new System
2222 - SMC ENT

Matt Cherry: Matt Cherry:

HID6136CKN000709G30DISAWR - 2220 - 1Interface 220Working
2222 - SMC EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 221Working
2323 - Computer Room 177A ENT

Matt Cherry: Matt Cherry:

Notes:

- The existing Door Contact is malfunctioning and will not report back properly. As the scope of our work does not inlcude repairing existing contacts or installing a new one on this door it was left inoperable.

- The Exit button that was in place before we began has been removed.HID6136CKN000709G30DISAWR - 2220 - 1Interface 230WorkingBad Contact / Exit Button has been Removed
2323 - Computer Room 177A EXIT

Matt Cherry: Matt Cherry:

Notes:

- The existing Door Contact is malfunctioning and will not report back properly. As the scope of our work does not inlcude repairing existing contacts or installing a new one on this door it was left inoperable.

- The Exit button that was in place before we began has been removed.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 231WorkingBad Contact / Exit Button has been Removed
2424 - Back Entrance NE ENT

Matt Cherry: Matt Cherry:

Notes:

Existing Emergency Exit button was attached to the new system to the RQE input. It is programmed to trip the door in the event it is pressed. There is no local siren.HID6136CKN000709G30DISAWR - 2220 - 1Interface 240WorkingEmergency Exit Button Attached to new System
2424 - Back Entrance NE EXIT

Matt Cherry: Matt Cherry:

Notes:

Existing Emergency Exit button was attached to the new system to the RQE input. It is programmed to trip the door in the event it is pressed. There is no local siren.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 241WorkingEmergency Exit Button Attached to new System
2525 - Comp Room 177B ENT

Matt Cherry: Matt Cherry:

Notes:

- The Emergency Exit button was removed from this door.

HID6136CKN000709G30DISAWR - 2220 - 1Interface 250WorkingExit Button Removed
2525 - Comp Room 177B EXIT
- The Emergency Exit button was removed from this door.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 251WorkingExit Button Removed
2626 - UPS B Rm 141 ENT

Matt Cherry: Matt Cherry:

Notes:

HID6136CKN000709G30DISAWR - 2220 - 1Interface 260Working
2626 - UPS B Rm 141 EXIT

Matt Cherry: Matt Cherry:

Notes:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 261Working
2727 - Battery Room 140 Exterior ENT

Matt Cherry: Matt Cherry:

HID6136CKN000709G30DISAWR - 2220 - 1Interface 270Working
2727 - Battery Room 140 Exterior EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 271Working
2828 - SE Entrance ENT

Matt Cherry: Matt Cherry:

HID6136CKN000709G30DISAWR - 2220 - 1Interface 280Working
2828 - SE Entrance EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 281Working
2929 - Supply Room ENT

Matt Cherry: Matt Cherry:

HID6136CKN000709G30DISAWR - 2220 - 1Interface 290Working
2929 - Supply Room EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 291Working
3030 - Mechanical Room 180 Exterior ENT

Matt Cherry: Matt Cherry:

Notes:

Due to an ongoing project on the base, this door's frame header has been removed and not re-installed. It is my understanding that the contractors responsible for the removal will be retunring to replace a large piece of equipment eventually and that the header will be reinstalled at that time. As such, no maglock is in place, and no door contact either. We have run all our wire down to the door and are fully prepared to attach the devices once they have retuned but until such time as they do we will be unable to complete this door.HID6136CKN000709G30DISAWR - 2220 - 1Interface 300WorkingHeader Removed, Door Incomplete.
3030 - Mechanical Room 180 Exterior EXIT

Matt Cherry: Matt Cherry:

Notes:

Due to an ongoing project on the base, this door's frame header has been removed and not re-installed. It is my understanding that the contractors responsible for the removal will be retunring to replace a large piece of equipment eventually and that the header will be reinstalled at that time. As such, no maglock is in place, and no door contact either. We have run all our wire down to the door and are fully prepared to attach the devices once they have retuned but until such time as they do we will be unable to complete this door.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 301WorkingHeader Removed, Door Incomplete.
3131 - Computer Room 177C ENT

Matt Cherry: Matt Cherry:

Notes:

- The Exit button that was in place before we began has been removed.HID6136CKN000709G30DISAWR - 2220 - 1Interface 310WorkingExit Button Removed
3131 - Computer Room 177C EXIT

Matt Cherry: Matt Cherry:

Notes:

- The Exit button that was in place before we began has been removed.HID6125CGN0007G30LDISAWR - 2220 - 1Interface 311WorkingExit Button Removed
3232 - Outside Entrance Rm 178 ENT

Matt Cherry: Matt Cherry:

HID6136CKN000709G31DISAWR - 2220 - 1Interface 320Working
3232 - Outside Entrance Rm 178 EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 1Interface 321Working
3333 - Back Entry to Supply ENT

Matt Cherry: Matt Cherry:

HID6136CKN000709G32DISAWR - 2220 - 2DISAWR - 2220 - 20Working
3333 - Back Entry to Supply EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 2DISAWR - 2220 - 21Working
3434 - Loading Dock ENT

Matt Cherry: Matt Cherry:

HID6136CKN000709G33DISAWR - 2220 - 2Interface 20Working
3434 - Loading Dock EXIT

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 2Interface 21Working
3535 - Loading Dock Rollup Door

Matt Cherry: Matt Cherry:

HID6136CKN000709G34DISAWR - 2220 - 2Interface 30Working
36Test Reader

Matt Cherry: Matt Cherry:

HID6125CGN0007G30LDISAWR - 2220 - 2Interface 31WorkingInstalled in Chuck's Office (170)
3736 - Mechanical Room 180 Interior ENT
The existing Door Contact is malfunctioning and will not report back properly. As the scope of our work does not inlcude repairing existing contacts or installing a new one on this door it was left inoperable.HID6136CKN000709G35DISAWR - 2220 - 2Interface 40WorkingBad Contact
3736 - Mechanical Room 180 Interior EXIT
The existing Door Contact is malfunctioning and will not report back properly. As the scope of our work does not inlcude repairing existing contacts or installing a new one on this door it was left inoperable.HID6125CGN0007G30LDISAWR - 2220 - 2Interface 41WorkingBad Contact
3737 - Battery Room 140 Interior ENT
The existing Door Contact is malfunctioning and will not report back properly. As the scope of our work does not inlcude repairing existing contacts or installing a new one on this door it was left inoperable.HID6136CKN000709G35DISAWR - 2220 - 2Interface 50WorkingBad Contact
3737 - Battery Room 140 Interior EXIT
The existing Door Contact is malfunctioning and will not report back properly. As the scope of our work does not inlcude repairing existing contacts or installing a new one on this door it was left inoperable.HID6125CGN0007G30LDISAWR - 2220 - 2Interface 51WorkingBad Contact
3838 - UPS Room 141 - Rear Door--DISAWR - 2220 - 2Input 1/Output 11WorkingMonitored/ Controlled Door only.
3939 - SMC - South Rear Door--DISAWR - 2220 - 2Input 1/Output 12WorkingMonitored/ Controlled Door only.
4040 - SMC - North Rear Door--DISAWR - 2220 - 2Input 1/Output 13WorkingMonitored/ Controlled Door only.
4141 - Smokers Gate--DISAWR - 2220 - 2Input 1/Output 14WorkingMonitored/ Controlled Door only.
4242 - Main Lobby - Side INT Door--DISAWR - 2220 - 2Input 15WorkingMonitored Door Only
4343 - Main Lobby - Side EXT Door--DISAWR - 2220 - 2Input 16WorkingMonitored Door Only

Software

Software Documentation
TypeModelVersion #Dongle IDLoginPassword
ACS and VideoLenel - Onguard7.0.1067.0107282Convergintatlanta.401

Intrusion

Intrusion Documentation
Zone #DescriptionDevice TypeDevice ModelPanel MakePanel ModelPanel DescriptionPanel LocationInput #Input Type
1Main Lobby Glass DCDoor Contact2707AD-LHoneywellVista 128BPDISA ISPIDS - 11Perimeter
2Room 181 NW DCDoor Contact2707AD-LHoneywellVista 128BPDISA ISPIDS - 12Perimeter
3Smoking Gate DCDoor Contact2707AD-LHoneywellVista 128BPDISA ISPIDS - 13Perimeter
4Room 181 SW DCDoor Contact2707AD-LHoneywellVista 128BPDISA ISPIDS - 14Perimeter
5Gazebo Gate DCDoor Contact2707AD-LHoneywellVista 128BPDISA ISPIDS - 15Perimeter
6Mechanical Room to Compound DCDoor Contact2707AD-LHoneywellVista 128BPDISA ISPIDS - 16Perimeter
7Compound Pedestrian Gate DCDoor Contact2707AD-LHoneywellVista 128BPDISA ISPIDS - 17Perimeter
8Battery Room 140 DCDoor Contact2707AD-LHoneywellVista 128BPDISA ISPIDS - 18Perimeter
9SE Entrance DCDoor Contact2707AD-LHoneywell4208UExpander - 1IDS - 21Perimeter
10UPS Room DCDoor Contact2707AD-LHoneywell4208UExpander - 1IDS - 22Perimeter
11Loading Dock DCDoor Contact2707AD-LHoneywell4208UExpander - 1IDS - 23Perimeter
12Back Entry to Supply Room DCDoor Contact2707AD-LHoneywell4208UExpander - 1IDS - 24Perimeter
13Outside Entrance to 178 DCDoor Contact2707AD-LHoneywell4208UExpander - 1IDS - 25Perimeter
14Back Entrance NE DCDoor Contact2707AD-LHoneywell4208UExpander - 1IDS - 26Perimeter
15Comp Room 177B DCDoor Contact2707AD-LHoneywell4208UExpander - 1IDS - 27Perimeter
16Mechanical Room 180 DCDoor Contact2707AD-LHoneywell4208UExpander - 1IDS - 28Perimeter