Photo_Notes1.docx

DOCX document 14 KB Posted

Attached to
Bldg. 503 Repair/Minor Const/Equipment Federal contract opportunity
Solicitation number
FA8201-16-B-0009
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Hill Air Force Base

About this file

Photo Notes1

View the file

Other files for this federal contract opportunity

Other files attached to Bldg. 503 Repair/Minor Const/Equipment, newest first.
File Type Posted
TECHNICAL_NOTESa.docx DOCX document
2ndSiteVistSigninSheets.pdf PDF
IFB_B503_Amend_04.docx DOCX document
B503KRSM092001-E4.0BLD_503_REPAIRS-E4.0.pdf PDF
503 Individual Pictures 73.pdf PDF
503 Individual Pictures 87.pdf PDF
503 Individual Pictures 65.pdf PDF
503 Individual Pictures 55.pdf PDF
Seed_Mix.pdf PDF
503 Individual Pictures 72.pdf PDF
503 Individual Pictures 57.pdf PDF
503 Individual Pictures 109.pdf PDF
RAMP_DETAIL.pdf PDF
503 Individual Pictures 83.pdf PDF
503 Individual Pictures 69.pdf PDF
INDsupplyQuote.pdf PDF
503 Individual Pictures 66.pdf PDF
Contractor_Questions_ _Answers_-_26_Oct_2016.pdf PDF
5600_System_CS23_GHD582_0516 —
503 Individual Pictures 98.pdf PDF
503 Individual Pictures 68.pdf PDF
503 Individual Pictures 95.pdf PDF
503 Individual Pictures 58.pdf PDF
503 Individual Pictures 82.pdf PDF
503 Individual Pictures 94.pdf PDF
200_Anti_Skid_Additive_CS37_GDH82_715.pdf PDF
503 Individual Pictures 96.pdf PDF
LS-102.pdf PDF
503 Individual Pictures 92.pdf PDF
A_INTRODUCTION.docx DOCX document
MaterialsEstimate.docx DOCX document
Manufdata1s.pdf PDF
503 Individual Pictures 106.pdf PDF
503 Individual Pictures 64.pdf PDF
503 Individual Pictures 102.pdf PDF
503 Individual Pictures 53.pdf PDF
503 Individual Pictures 104.pdf PDF
Manufdata1.pdf PDF
503 Individual Pictures 103.pdf PDF
503 Individual Pictures 107.pdf PDF
7400_System_450_VOC_Primers_RO11_GDH1090.pdf PDF
503 Individual Pictures 85.pdf PDF
503 Individual Pictures 78.pdf PDF
B503_Amend_02.docx DOCX document
K092001-B503_Specifications_Rev_7.25.16.docx DOCX document
Storm_Water_Pollution_Prevention_Plan_Building_680_KRSM_152043.pdf PDF
CEN-CEIE_PLAN_REVIEW_CHECKLIST.docx DOCX document
BASE_FACILITY_DESIGN_STANDARD.docx DOCX document
APPENDIX_C_MASTER_ON_or_OFF_BASE_UPDATED_March_2015.docx DOCX document
BLDG._503_EXTERIOR_UPGRADE_SET_sow.pdf PDF
Show all 50

Bldg. 503 Repair/Minor Const/Equipment has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PHOTO NOTES 1

If you choose to print the photographs to ensure you get the North arrow and labeling: Print the PDF version, Ensure the box “Fit” is checked under page size and handling and make sure the orientation is in portrait.

The following notes are included to add clarification to the project requirements. The number on the left indicates the photo number which is then followed by the building number and the requirement. Not all photographs are included on this list as they have been addressed in the Questions, Quantities, or Drawings.

8Building 503 handicap ramp, side joints to caulk with Loctite Crack Filler SL #45005
11Building 503, replace sidewalk section around this column when performing 45° infill work
12Building 503A, repair bollards with Loctite Magna-Grout #45002
13Building 503, remove stump and re-sod
14Building 503, new curbing required
16Building 503, new curbing required
17Building 503, remove tree in foreground, remove stump and re-sod
39Building 507, repair asphalt, provide access cover to well, provide permanent nameplate for well to read:
Ground Source Heat Pump Investigation Well
40ABuilding 507, repair HP ramp deterioration along entire ramp
44ABuilding 507, repair outer perimeter gap around this pad as shown in photograph 45A
49Building 503A, replace sump door with highly corrosion resistant door, provide drain holes on new door
50Building 503A, location of check valve in storm sewer line
53Building 503A, trench pumping system
54Building 507, modify/repair to eliminate tripping hazard
57Building 503H, insulate copper supply line
65ABuilding 503A, boiler room threshold replace
72Building 503, grind raised edges
73Building 503, repair, square up and level stairs with Loctite MagnaGrout #45002

Install Safestep fiberglass overlay on these stairs, ensure no water is able to enter under overlays after installation. Ensure no trip edge is present.

81Building 503, DLA portion of building in Southeast corner showing EFIS repair
86Building 503B, extract core, ascertain purpose and repair, provide cover and or lift ring if required
87Building 503B, Eastside ramp edge that needs yellow and black safety painting
90BBuilding 503, photograph showing repair of dock area and corner of building area
91Building 503, loading dock angle and bumper support painting
92Building 503, columns along the North dock, chipping of concrete and grinding not required, treat with Loctite Extend as a primer and paint entire column
93Building 503, ventilation requirement removed from project
95Building 503, location of strip curtain
98Building 503, prep surface using low dust techniques as lead paint is present, treat with Loctite Extend

and paint safety yellow.

99Building 503, bird screen area, existing screening shown on right. Also see 99A, 99B, 99C.
101Building 503B, provide lift ring and infill edges with Loctite MagnaCrete
106Building 503A, a portion of the deteriorated sidewalk that needs repair on Southgate Avenue.

File details come from the government source that posted it. Updated .