ALKYD TECHNICAL DATA RO-11
7400 SYSTEM
450 VOC ALKYD ENAMEL PRIMERS
Form: GDH-1090 Rev.: 032416
.DESCRIPTION AND USES .
Damp Proof Red Primer is a special modified alkyd primer designed specifically to protect rusted steel against further rust and corrosion. Use on rusted steel surfaces where only minimal surface preparation (scraping and wire brushing) is practical.
Heavy Duty Rust-Inhibitive Primers are special high solids alkyd primers with rust-inhibitive pigmentation for heavy-duty corrosion protection of steel surfaces subjected to extreme rust-producing environments, such as coastal areas or heavy industrial atmospheres. Use on clean, heavily rusted, lightly rusted, abrasive blasted or previously painted surfaces.
Zinc Chromate Primers are general purpose, rust-inhibitive, modified alkyd primers designed for lightly rusted, bare, abrasive blasted or previously painted surfaces. These primers may be used as intermediate coats for maximum corrosion protection. These primers are not for use on galvanized steel.
.PRODUCTS .
DAMP PROOF RED PRIMER
1-Gallon 5-Gallon Description
769402 769300 Red
HEAVY DUTY RUST-INHIBITIVE PRIMERS
1-Gallon 5-Gallon Description
1060402 — Gray 1069402 1069300 Red
ZINC CHROMATE RUST-INHIBITIVE PRIMERS
1-Gallon 5-Gallon Description
960402 960300 Yellow X60402 — Red
COMPANION PRODUCTS .
RECOMMENDED TOPCOATS
7400 System DTM 450 VOC Alkyd Enamel (#960402 and #X60402 as intermediate primers)
PRODUCT APPLICATION .
SURFACE PREPARATION
ALL SURFACES: Remove all dirt, grease, oil, salt and chemical contaminants by washing the surface with Pure Strength
Cleaner/Degreaser, item #3599402, commercial detergent or other suitable cleaner. Rinse thoroughly with fresh water and allow to fully dry. All surfaces must be dry at time of application.
STEEL: Hand tool clean (SSPC-SP-2) or power tool clean (SSPC-SP-3) to remove all loose rust, mill scale, and deteriorated previous coatings. Abrasive blasting to a minimum Commercial Grade (SSPC-SP-6, NACE 3) with a 1-2 mils (25-50µ) surface profile is recommended for optimal performance. Abrasive blast cleaned steel requires two coats of primer. 769 Primer is intended for sound rusted steel only. Do not use 769 Primer on clean or abrasive clean steel.
PREVIOUSLY COATED: Previously coated surfaces must be sound and in good condition. Smooth, hard, or glossy finishes should be scarified by sanding to create a surface profile. The Rust-Oleum Industrial Enamel Primers are compatible with most coatings, but a test patch is suggested.
APPLICATION
Apply only when the air and surface temperatures are between 32-100°F (0-38°C) and the surface temperature is at least 5°F (3°C) above the dew point. Abrasive blast clean steel requires two coats of primer.
TECHNICAL DATA
7400 SYSTEM 450 VOC ALKYD ENAMEL PRIMERS
Form: GDH-1090 Rev.: 032416
PRODUCT APPLICATION (cont.) .
EQUIPMENT RECOMMENDATIONS
BRUSH: Use a good quality natural or synthetic bristle brush.
ROLLER: Use a good quality natural or synthetic cover.
AIR-ATOMIZED SPRAY:
Method Fluid Tip Fluid Delivery Atomizing Pressure
Pressure 0.055-0.070 10-16 oz./min. 25-60 psi Siphon 0.055-0.070 — 25-60 psi HVLP (var.) 0.043-0.070 8-10 oz./min. 10 psi at the tip
AIRLESS SPRAY:
Fluid Pressure Fluid Tip Filter Mesh
1600-2400 psi 0.013-0.017 100
THINNING
BRUSH/ROLLER: 333 Thinner: Normally not required.
Use 5-10% if needed (approximately ½ pint per gallon).
AIR ATOMIZED SPRAY: 333 Thinner: Use 10-20% or as needed (approximately 1½ pints per gallon).
AIRLESS SPRAY: 333 Thinner: Thinning normally not required. Use 5-10% if needed (approximately ½ pint per gallon).
CLEAN UP
633402 Thinner or mineral spirits.
PERFORMANCE CHARACTERISTICS .
SYSTEM TESTED
Primer: 769 Damp Proof Red Primer Topcoat: N/A
PENCIL HARDNESS
METHOD: ASTM D3363, 30 days
RESULT: 5B
CONICAL FLEXIBILITY
METHOD: ASTM D522
RESULT: 10.8% elongation
IMPACT RESISTANCE (direct/reverse)
METHOD: ASTM D2794
RESULT: 106 inch lbs. / 60 inch lbs.
TABER ABRASION
METHOD: ASTM D4060, CS10 wheel, 1000 cycles, 500 load.
RESULT: 67 mg loss
For chemical and corrosion resistance, see page 4 of the Rust-Oleum Industrial Brands Catalog (Form #275585).
TECHNICAL DATA
7400 SYSTEM 450 VOC ALKYD ENAMEL PRIMERS
Rust-Oleum Corporation Form: GDH-1090 11 Hawthorn Parkway Phone: 877•385•8155 Rev.: 032416 Vernon Hills, Illinois 60061 www.rustoleum.com/industrial An RPM Company
,PHYSICAL PROPERTIES .
769 DAMP PROOF 1060/1069 HEAVY-DUTY 960/X60 RUST-INHIBITIVE
Resin Type Modified Alkyd Modified Alkyd Modified Alkyd
Pigment Type
Zinc Molybdate, Red Iron Oxide
Titanium dioxide, Strontium Zinc
Phosphosilicate, Brown Iron Oxide (1069 only)
Zinc Chromate (X60/960), Yellow Iron Oxide
Solvents Aliphatic Hydrocarbons Aliphatic Hydrocarbons Aliphatic Hydrocarbons
Weight Per Gallon 11.4 lbs. 11.8-12.0 lbs. 10.4-10.7 lbs.
Per Liter 1.4 kg 1.4-1.5 kg 1.2-1.3 kg
Solids By Weight 69.0% 76.5-76.8% 62-66%
By Volume 45.2% 57-58% 40-43%
Volatile Organic Compounds <450 g/l (3.8 lbs./gal.) <340 g/l (2.83 lbs./gal.) <450 g/l (3.8 lbs./gal.)
Recommended Dry Film (DFT) Per Coat
1-2 mils (25-50µ)
1.5-2.5 mils (37.5-62.5µ)
1-2 mils (25-50µ)
Wet Film to Achieve DFT (unthinned material)
2-4.5 mils (50-112.5µ)
2.5-4.5 mils (62.5-112.5µ)
2.5-5.0 mils (62.5-125.0µ)
Theoretical Coverage at 1 mil DFT (25µ)
725 sq.ft./gal.
(17.8 m2/l)
914-930 sq.ft./gal.
(22.5-22.9 m2/l)
640-690 sq.ft./gal.
(15.7-17.0 m2/l)
Practical Coverage at Recommended DFT (assumes 15% material loss)
305-615 sq.ft./gal.
(7.5-15.1 m2/l)
310-520 sq.ft./gal.
(7.6-12.8 m2/l)
270-585 sq.ft./gal.
(6.6-14.4 m2/l)
Dry Times at 70-80F (21-27°C) and 50% Relative Humidity
Tack-free 3-5 hours 3-5 hours 2-4 hours
Handle 5-9 hours 5-10 hours 4-6 hours
Recoat 24-48 hours 24-48 hours 24 hours
Force Cure 30 minutes at 225°F (107°C) (dry to handle after cooling)
30 minutes at 225°F (107°C) (dry to handle after cooling)
30 minutes at 225°F (107°C) (dry to handle after cooling)
Dry Heat Resistance 212°F (100°C) 212°F (100°C) 960/1280: 212°F (100°C) X60: 350°F (177°)
Shelf Life 5 years 5 years 5 years
Safety Information For additional information, see SDS
Calculated values are shown and may vary slightly from the actual manufactured material.
The technical data and suggestions for use contained herein are correct to the best of our knowledge, and offered in good faith. The statements of this literature do not constitute a warranty, express, or implied, as to the performance of these products. As conditions and use of our materials are beyond our control, we can guarantee these products only to conform to our standards of quality, and our liability, if any, will be limited to replacement of defective materials. All technical information is subject to change without notice.