7400_System_450_VOC_Primers_RO11_GDH1090.pdf

PDF 168 KB Posted

Attached to
Bldg. 503 Repair/Minor Const/Equipment
Solicitation number
FA8201-16-B-0009
Issued by

About this file

7400 sys 450 voc

View the file

Other files

File Type Posted
TECHNICAL_NOTESa.docx DOCX document
B503KRSM092001-E4.0BLD_503_REPAIRS-E4.0.pdf PDF
2ndSiteVistSigninSheets.pdf PDF
Bldg-503PB_WO53153.xlsx XLSX spreadsheet
IFB_B503_Amend_04.docx DOCX document
Bldg503_asbestos_WO53153_Repair_Exterior.xlsx XLSX spreadsheet
QA_15_NOV_16_2ND_SITE_VISITcsr1_(002).docx DOCX document
503 Individual Pictures 54.pdf PDF
Manufdata1s.pdf PDF
503 Individual Pictures 84.pdf PDF
ICS_Quote_1609-160836.pdf PDF
503 Individual Pictures 93.pdf PDF
503 Individual Pictures 62.pdf PDF
503 Individual Pictures 83.pdf PDF
503 Individual Pictures 64.pdf PDF
503 Individual Pictures 102.pdf PDF
INDsupplyQuote.pdf PDF
503 Individual Pictures 69.pdf PDF
Contractor_Questions_ _Answers_-_26_Oct_2016.pdf PDF
503 Individual Pictures 66.pdf PDF
503 Individual Pictures 70.pdf PDF
503 Individual Pictures 76.pdf PDF
503 Individual Pictures 106.pdf PDF
5600_System_CS23_GHD582_0516 —
503 Individual Pictures 98.pdf PDF
503 Individual Pictures 51.pdf PDF
503 Individual Pictures 79.pdf PDF
503 Individual Pictures 53.pdf PDF
Manufdata1.pdf PDF
503 Individual Pictures 104.pdf PDF
503 Individual Pictures 73.pdf PDF
503 Individual Pictures 107.pdf PDF
503 Individual Pictures 103.pdf PDF
503 Individual Pictures 78.pdf PDF
Manufdata2.pdf PDF
503 Individual Pictures 85.pdf PDF
503 Individual Pictures 95.pdf PDF
503 Individual Pictures 68.pdf PDF
503 Individual Pictures 87.pdf PDF
503 Individual Pictures 58.pdf PDF
503 Individual Pictures 82.pdf PDF
503 Individual Pictures 94.pdf PDF
503 Individual Pictures 105.pdf PDF
503 Individual Pictures 88.pdf PDF
503 Individual Pictures 75.pdf PDF
ASPHALT_DETAIL.pdf PDF
503_Quantities.docx DOCX document
UT104.txt TXT text file
503 Individual Pictures 74.pdf PDF
503 Individual Pictures 65.pdf PDF
Show 40 more

Latest 50 of 107 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ALKYD TECHNICAL DATA RO-11

7400 SYSTEM

450 VOC ALKYD ENAMEL PRIMERS

Form: GDH-1090 Rev.: 032416

.DESCRIPTION AND USES .

Damp Proof Red Primer is a special modified alkyd primer designed specifically to protect rusted steel against further rust and corrosion. Use on rusted steel surfaces where only minimal surface preparation (scraping and wire brushing) is practical.

Heavy Duty Rust-Inhibitive Primers are special high solids alkyd primers with rust-inhibitive pigmentation for heavy-duty corrosion protection of steel surfaces subjected to extreme rust-producing environments, such as coastal areas or heavy industrial atmospheres. Use on clean, heavily rusted, lightly rusted, abrasive blasted or previously painted surfaces.

Zinc Chromate Primers are general purpose, rust-inhibitive, modified alkyd primers designed for lightly rusted, bare, abrasive blasted or previously painted surfaces. These primers may be used as intermediate coats for maximum corrosion protection. These primers are not for use on galvanized steel.

.PRODUCTS .

DAMP PROOF RED PRIMER

1-Gallon 5-Gallon Description

769402 769300 Red

HEAVY DUTY RUST-INHIBITIVE PRIMERS

1-Gallon 5-Gallon Description

1060402 — Gray 1069402 1069300 Red

ZINC CHROMATE RUST-INHIBITIVE PRIMERS

1-Gallon 5-Gallon Description

960402 960300 Yellow X60402 — Red

COMPANION PRODUCTS .

RECOMMENDED TOPCOATS

7400 System DTM 450 VOC Alkyd Enamel (#960402 and #X60402 as intermediate primers)

PRODUCT APPLICATION .

SURFACE PREPARATION

ALL SURFACES: Remove all dirt, grease, oil, salt and chemical contaminants by washing the surface with Pure Strength

Cleaner/Degreaser, item #3599402, commercial detergent or other suitable cleaner. Rinse thoroughly with fresh water and allow to fully dry. All surfaces must be dry at time of application.

STEEL: Hand tool clean (SSPC-SP-2) or power tool clean (SSPC-SP-3) to remove all loose rust, mill scale, and deteriorated previous coatings. Abrasive blasting to a minimum Commercial Grade (SSPC-SP-6, NACE 3) with a 1-2 mils (25-50µ) surface profile is recommended for optimal performance. Abrasive blast cleaned steel requires two coats of primer. 769 Primer is intended for sound rusted steel only. Do not use 769 Primer on clean or abrasive clean steel.

PREVIOUSLY COATED: Previously coated surfaces must be sound and in good condition. Smooth, hard, or glossy finishes should be scarified by sanding to create a surface profile. The Rust-Oleum Industrial Enamel Primers are compatible with most coatings, but a test patch is suggested.

APPLICATION

Apply only when the air and surface temperatures are between 32-100°F (0-38°C) and the surface temperature is at least 5°F (3°C) above the dew point. Abrasive blast clean steel requires two coats of primer.

TECHNICAL DATA

7400 SYSTEM 450 VOC ALKYD ENAMEL PRIMERS

Form: GDH-1090 Rev.: 032416

PRODUCT APPLICATION (cont.) .

EQUIPMENT RECOMMENDATIONS

BRUSH: Use a good quality natural or synthetic bristle brush.

ROLLER: Use a good quality natural or synthetic cover.

AIR-ATOMIZED SPRAY:

Method Fluid Tip Fluid Delivery Atomizing Pressure

Pressure 0.055-0.070 10-16 oz./min. 25-60 psi Siphon 0.055-0.070 — 25-60 psi HVLP (var.) 0.043-0.070 8-10 oz./min. 10 psi at the tip

AIRLESS SPRAY:

Fluid Pressure Fluid Tip Filter Mesh

1600-2400 psi 0.013-0.017 100

THINNING

BRUSH/ROLLER: 333 Thinner: Normally not required.

Use 5-10% if needed (approximately ½ pint per gallon).

AIR ATOMIZED SPRAY: 333 Thinner: Use 10-20% or as needed (approximately 1½ pints per gallon).

AIRLESS SPRAY: 333 Thinner: Thinning normally not required. Use 5-10% if needed (approximately ½ pint per gallon).

CLEAN UP

633402 Thinner or mineral spirits.

PERFORMANCE CHARACTERISTICS .

SYSTEM TESTED

Primer: 769 Damp Proof Red Primer Topcoat: N/A

PENCIL HARDNESS

METHOD: ASTM D3363, 30 days

RESULT: 5B

CONICAL FLEXIBILITY

METHOD: ASTM D522

RESULT: 10.8% elongation

IMPACT RESISTANCE (direct/reverse)

METHOD: ASTM D2794

RESULT: 106 inch lbs. / 60 inch lbs.

TABER ABRASION

METHOD: ASTM D4060, CS10 wheel, 1000 cycles, 500 load.

RESULT: 67 mg loss

For chemical and corrosion resistance, see page 4 of the Rust-Oleum Industrial Brands Catalog (Form #275585).

TECHNICAL DATA

7400 SYSTEM 450 VOC ALKYD ENAMEL PRIMERS

Rust-Oleum Corporation Form: GDH-1090 11 Hawthorn Parkway Phone: 877•385•8155 Rev.: 032416 Vernon Hills, Illinois 60061 www.rustoleum.com/industrial An RPM Company

,PHYSICAL PROPERTIES .

769 DAMP PROOF 1060/1069 HEAVY-DUTY 960/X60 RUST-INHIBITIVE

Resin Type Modified Alkyd Modified Alkyd Modified Alkyd

Pigment Type

Zinc Molybdate, Red Iron Oxide

Titanium dioxide, Strontium Zinc

Phosphosilicate, Brown Iron Oxide (1069 only)

Zinc Chromate (X60/960), Yellow Iron Oxide

Solvents Aliphatic Hydrocarbons Aliphatic Hydrocarbons Aliphatic Hydrocarbons

Weight Per Gallon 11.4 lbs. 11.8-12.0 lbs. 10.4-10.7 lbs.

Per Liter 1.4 kg 1.4-1.5 kg 1.2-1.3 kg

Solids By Weight 69.0% 76.5-76.8% 62-66%

By Volume 45.2% 57-58% 40-43%

Volatile Organic Compounds <450 g/l (3.8 lbs./gal.) <340 g/l (2.83 lbs./gal.) <450 g/l (3.8 lbs./gal.)

Recommended Dry Film (DFT) Per Coat

1-2 mils (25-50µ)

1.5-2.5 mils (37.5-62.5µ)

1-2 mils (25-50µ)

Wet Film to Achieve DFT (unthinned material)

2-4.5 mils (50-112.5µ)

2.5-4.5 mils (62.5-112.5µ)

2.5-5.0 mils (62.5-125.0µ)

Theoretical Coverage at 1 mil DFT (25µ)

725 sq.ft./gal.

(17.8 m2/l)

914-930 sq.ft./gal.

(22.5-22.9 m2/l)

640-690 sq.ft./gal.

(15.7-17.0 m2/l)

Practical Coverage at Recommended DFT (assumes 15% material loss)

305-615 sq.ft./gal.

(7.5-15.1 m2/l)

310-520 sq.ft./gal.

(7.6-12.8 m2/l)

270-585 sq.ft./gal.

(6.6-14.4 m2/l)

Dry Times at 70-80F (21-27°C) and 50% Relative Humidity

Tack-free 3-5 hours 3-5 hours 2-4 hours

Handle 5-9 hours 5-10 hours 4-6 hours

Recoat 24-48 hours 24-48 hours 24 hours

Force Cure 30 minutes at 225°F (107°C) (dry to handle after cooling)

30 minutes at 225°F (107°C) (dry to handle after cooling)

30 minutes at 225°F (107°C) (dry to handle after cooling)

Dry Heat Resistance 212°F (100°C) 212°F (100°C) 960/1280: 212°F (100°C) X60: 350°F (177°)

Shelf Life 5 years 5 years 5 years

Safety Information For additional information, see SDS

Calculated values are shown and may vary slightly from the actual manufactured material.

The technical data and suggestions for use contained herein are correct to the best of our knowledge, and offered in good faith. The statements of this literature do not constitute a warranty, express, or implied, as to the performance of these products. As conditions and use of our materials are beyond our control, we can guarantee these products only to conform to our standards of quality, and our liability, if any, will be limited to replacement of defective materials. All technical information is subject to change without notice.