Bldg503_asbestos_WO53153_Repair_Exterior.xlsx

XLSX spreadsheet 49 KB Posted

Attached to
Bldg. 503 Repair/Minor Const/Equipment
Solicitation number
FA8201-16-B-0009
Issued by

About this file

Bldg. 503 asbestos survey

View the file

Other files

File Type Posted
TECHNICAL_NOTESa.docx DOCX document
B503KRSM092001-E4.0BLD_503_REPAIRS-E4.0.pdf PDF
2ndSiteVistSigninSheets.pdf PDF
Bldg-503PB_WO53153.xlsx XLSX spreadsheet
IFB_B503_Amend_04.docx DOCX document
QA_15_NOV_16_2ND_SITE_VISITcsr1_(002).docx DOCX document
503 Individual Pictures 54.pdf PDF
Manufdata1s.pdf PDF
503 Individual Pictures 84.pdf PDF
ICS_Quote_1609-160836.pdf PDF
503 Individual Pictures 93.pdf PDF
503 Individual Pictures 62.pdf PDF
503 Individual Pictures 83.pdf PDF
503 Individual Pictures 64.pdf PDF
503 Individual Pictures 102.pdf PDF
INDsupplyQuote.pdf PDF
503 Individual Pictures 69.pdf PDF
Contractor_Questions_ _Answers_-_26_Oct_2016.pdf PDF
503 Individual Pictures 66.pdf PDF
503 Individual Pictures 70.pdf PDF
503 Individual Pictures 76.pdf PDF
503 Individual Pictures 106.pdf PDF
5600_System_CS23_GHD582_0516 —
503 Individual Pictures 98.pdf PDF
503 Individual Pictures 51.pdf PDF
503 Individual Pictures 79.pdf PDF
503 Individual Pictures 53.pdf PDF
Manufdata1.pdf PDF
503 Individual Pictures 104.pdf PDF
503 Individual Pictures 73.pdf PDF
7400_System_450_VOC_Primers_RO11_GDH1090.pdf PDF
503 Individual Pictures 107.pdf PDF
503 Individual Pictures 103.pdf PDF
503 Individual Pictures 78.pdf PDF
Manufdata2.pdf PDF
503 Individual Pictures 85.pdf PDF
503 Individual Pictures 95.pdf PDF
503 Individual Pictures 68.pdf PDF
503 Individual Pictures 87.pdf PDF
503 Individual Pictures 58.pdf PDF
503 Individual Pictures 82.pdf PDF
503 Individual Pictures 94.pdf PDF
503 Individual Pictures 105.pdf PDF
503 Individual Pictures 88.pdf PDF
503 Individual Pictures 75.pdf PDF
ASPHALT_DETAIL.pdf PDF
503_Quantities.docx DOCX document
UT104.txt TXT text file
503 Individual Pictures 74.pdf PDF
503 Individual Pictures 65.pdf PDF
Show 40 more

Latest 50 of 107 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

DEPARTMENT OF THE AIR FORCE
75 CIVIL ENGINEERING (CEOHA)
HILL AIR FORCE BASE, UTAH
LIMITED ASBESTOS INSPECTION REPORT,HILL AFB BUILDING, 503
REPAIR/MODIFY EXTERIOR OF FACILITY
Date Requested:June 2009Inspection Date:23 July 2009
Inspected By:Neldon Anderson (Utah Certified Asbestos Insector ASB#-0054)
Re-Inspection Date:24 August 2016
Requester:Chris RowinsRe-Inspected By:Traver Andreasen (Utah Certified Asbestos Inspector ASB#-4397)
Organization:309 CMXG/EN
Location & Building:HILL AFB BUILDING, 503
Work Order:53153
Affected Area:Exterior of 503, 503A, and 503H
Statement of Work:Repair concrete and railings.
Install concrete pad for break area and sidewalk to gate 30.
Re-stripe parking lot and LEAN areas.
Repair masonry and utilities.
Build canopy for stairs on east side of 503 A.
Build canopy for break area.
Repair gate 29 and install cameras at gates 29 and 30
Provide new landscaping.

This inspection was performed in accordance with the Utah Division of Air Quality (DAQ) requirements as found in the Utah Air Quality Rule R307-801-10. This inspection report is required to be on site during all abatement, renovation, and demolition activities. Samples referenced in this report were analyzed by polarized light microscopy (PLM) utilizing method 600R-93-116 by The Science and Engineering laboratory at Hill Air Force Base, Utah.

Civil Engineering personnel also reviewed previous asbestos inspection reports of suspect asbestos containing building materials (ACM) that could potentially be encountered in this area. The information gathered from all current and previous inspections is shown below by homogenous area.

SUMMARY OF ASBESTOS CONTAINING MATERIALS FOUND

MATERIAL TYPEASBESTOSFRIABILITY (During Removal)**RACM *Category I *Category IIQUANTITY*LOCATIONS FOUND
N/AN/AN/AN/AN/AN/A
*Per UDAQ definition.
RACM: Regulated Asbestos-Containing Material (RACM)" means friable ACM, Category I non-friable ACM that has become friable, Category I non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading, or Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation project operations.
Category I Non-Friable ACM: Asbestos-containing packings, gaskets, resilient floor coverings, or asphalt roofing products containing more than 1% asbestos as determined by using the method specified in 40 CFR Part 763, Subpart E, Appendix E, Section 1, Polarized Light Microscopy (PLM).
Category II Non-Friable ACM: Any material, excluding Category I non- friable ACM, containing more than 1% asbestos as determined by using the methods specified in 40 CFR Part 763, Subpart E, Appendix E, Section 1, Polarized Light Microscopy (PLM) that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.
Locations found: Locations of building materials as described in this report indicate where they were found, but do not necessarily mean that these are the only locations where these materials may be encountered during the project.
Summary of materials containing ≤1% was identified via "Point Counting". ≤1% is not considered to be an asbestos containing material, but special handling/packaging requirements are necessary per OSHA 29CFR 1926.1101 and 29CFR 1910.1001
MATERIAL TYPEASBESTOSQUANTITY*LOCATIONS FOUND
N/AN/AN/AN/A

The following is a list of the "Suspect Materials" that were sampled as part of this inspection:

Thermal Systems Pipe Insulation, BlackCeiling Plaster, Brown
Thermal Systems Pipe Insulation, Metal/White/YellowExterior Drywall Ceiling/Joint Compound Soffit, Brown/White
Thermal System Pipe Fitting Insulation, Metal/Yellow
A total of11samples reference the5suspect materials assesses as part of the inspection.
The following table summarizes the sampling data.
Homogenous Building Material, Description, Location, Quantity.Sample #Sample LocationResults
Thermal Systems Pipe Insulation, Black, Units 9689 and 11815, 100 Linear FeetGM082833West, Unit 9689None Detected
GM082834West, Unit 11815None Detected
GM082835Northwest, Unit 11815None Detected
Thermal Systems Pipe Insulation, Metal Over White Over Yellow, Tank Area, 100 Linear FeetGM082836Northeast, Tank AreaNone Detected
Thermal System Pipe Fitting Insulation, Metal Over Yellow, Tank Area, 25 Linear FeetGM082837Northeast, Tank AreaNone Detected
Ceiling Plaster, Brown, East EntranceGM162533East Center, East EntranceNone Detected
GM162534Northeast, East EntranceNone Detected
GM162535Southeast, East EntranceNone Detected
Exterior Drywall Ceiling/Joint Compound Soffit, Brown Over White, East EntranceGM162536Northwest, East EntranceNone Detected
GM162537Southeast, East EntranceNone Detected
GM162538Northeast, East EntranceNone Detected

Per EPA requirements, all materials analyzed as containing ≤10% asbestos are point counted utilizing EPA method 600/R-93/116.

POTENTIAL FOR ADDITIONAL MATERIALS:
This inspection report only encompasses the areas/materials designated within this report. Should the scope of the project be altered in any way or any materials found that are not identified in this report shall require additional assessment. This report cannot be used for any other projects within the building.
This report was inspected by:
Traver Andreasen (Utah Certified Asbestos Inspector ASB#-4397)
of the 75 CES/CEOHA Asbestos/LBP Shop.
Any questions or concerns regarding this inspection report or if any new suspect asbestos containing material (ACM) is encountered, stop work and contact the personnel listed below for further assistance.

CONTACT INFORMATION

Asbetsos/LBP Shop 75 CES(CEOHA)

Supervisor: Traver Andreasen:DSN: (801)777-8006Asbestos/LBP Shop (801)777-8006
Cell: (801)430-3976

Building: 503

Repairs/Modifications to ExteriorWO#: 53153
&P12 September 2016

1115 Hours

Sheet2

Traver Andreasen (Utah Certified Asbestos Inspector ASB#-4397)
Chase Johnson (Utah Certified Asbestos Inspector ASB#-5645)
Nickolas King (Utah Certified Asbestos Inspector ASB#-2257)
Raudel Arteaga (Utah Certified Asbestos Inspector ASB#-5863)