Manufdata1s.pdf

PDF 2 MB Posted

Attached to
Bldg. 503 Repair/Minor Const/Equipment Federal contract opportunity
Solicitation number
FA8201-16-B-0009
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Hill Air Force Base

About this file

Manufdata1 or Government approved equal

View the file

Other files for this federal contract opportunity

Other files attached to Bldg. 503 Repair/Minor Const/Equipment, newest first.
File Type Posted
IFB_B503_Amend_04.docx DOCX document
TECHNICAL_NOTESa.docx DOCX document
2ndSiteVistSigninSheets.pdf PDF
B503KRSM092001-E4.0BLD_503_REPAIRS-E4.0.pdf PDF
5600_System_CS23_GHD582_0516 —
503 Individual Pictures 98.pdf PDF
503 Individual Pictures 68.pdf PDF
503 Individual Pictures 95.pdf PDF
503 Individual Pictures 58.pdf PDF
503 Individual Pictures 82.pdf PDF
503 Individual Pictures 94.pdf PDF
200_Anti_Skid_Additive_CS37_GDH82_715.pdf PDF
503 Individual Pictures 96.pdf PDF
LS-102.pdf PDF
503 Individual Pictures 92.pdf PDF
A_INTRODUCTION.docx DOCX document
MaterialsEstimate.docx DOCX document
Manufdata1s.pdf PDF
503 Individual Pictures 106.pdf PDF
503 Individual Pictures 64.pdf PDF
503 Individual Pictures 102.pdf PDF
503 Individual Pictures 73.pdf PDF
503 Individual Pictures 87.pdf PDF
503 Individual Pictures 65.pdf PDF
503 Individual Pictures 55.pdf PDF
Seed_Mix.pdf PDF
503 Individual Pictures 72.pdf PDF
503 Individual Pictures 57.pdf PDF
503 Individual Pictures 109.pdf PDF
RAMP_DETAIL.pdf PDF
Photo_Notes1.docx DOCX document
503 Individual Pictures 83.pdf PDF
503 Individual Pictures 69.pdf PDF
INDsupplyQuote.pdf PDF
503 Individual Pictures 66.pdf PDF
Contractor_Questions_ _Answers_-_26_Oct_2016.pdf PDF
503 Individual Pictures 53.pdf PDF
503 Individual Pictures 104.pdf PDF
Manufdata1.pdf PDF
503 Individual Pictures 103.pdf PDF
503 Individual Pictures 107.pdf PDF
7400_System_450_VOC_Primers_RO11_GDH1090.pdf PDF
503 Individual Pictures 85.pdf PDF
B503_Amend_02.docx DOCX document
BLDG._503_EXTERIOR_UPGRADE_SET_sow.pdf PDF
K092001-B503_Specifications_Rev_7.25.16.docx DOCX document
Storm_Water_Pollution_Prevention_Plan_Building_680_KRSM_152043.pdf PDF
CEN-CEIE_PLAN_REVIEW_CHECKLIST.docx DOCX document
BASE_FACILITY_DESIGN_STANDARD.docx DOCX document
APPENDIX_C_MASTER_ON_or_OFF_BASE_UPDATED_March_2015.docx DOCX document
Show all 50

Bldg. 503 Repair/Minor Const/Equipment has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

/!,@((T/TEe

PRODUCT DESCRIPTION

LOCTITE® Fixmaster® Magna-Crete® provides the following product characteristics· Technology Magnesium phosphate-based Appearance Gray liquid (mix to desired consistency) Components Two component - requires mixing Cure Room temperature cure after mixing Application Flooring & grout Specific Benefit • Easier to work with

• Applicator friendly

• Fast setting

• Cure temp.: -26 °C to +46 °C

LOCTITE® Fixmaster® Magna-Crete® is a unique, two-component, rapid setting concrete repair and grouting system that outperforms conventional concrete repairs. A high performance, magnesium phosphate-based system, LOCTITE® Fixmaster® Magna-Crete® cures faster than concrete, and unlike concrete, it bonds to new and old concrete as well as most construction materials including wood and steel. Since LOCTITE® Fixmaster® Magna-Crete® does not use a water additive, this repair system can be applied at virtually any temperature without shrinkage and is freeze/thaw and deicing salt resistant. This product is typically used for the repair of concrete highway walls, pot holes, airport runways, anchoring machinery, commercial refrigeration floors, loading docks, grouting bedplates and soleplates, columns and bridge decks, parking structure joints, concrete pillars, floor repairs, ramps, rail grouting, anchoring bolts and handrails.

This product is typically used in applications with an operating range of -26 °C to +1090 °C.

TYPICAL PROPERTIES

Coverage, 3.8 liter (1 gallon)

Coverage, 19 liter (5 gallon)

0.45 m2 @ 0.64 cm thick/4.54 kg (4.8 ft' @ 0.25 in thick/10 lb)

2.0 m• @ 0.64 cm thick/20.4 kg (21 .6 ft2 @ 0.25 in thick/45 lb)

TYPICAL CURING PERFORMANCE

Set Time, minutes:

Initial Final

TYPICAL PERFORMANCE

Compressive Strength:

After 2 hours

After 3 days

After 28 days

After 1 year

N/mm2

(psi) N/mm2

(psi) N/mm2

(psi) N/mm2

(psi)

3 to 11 15 to 22

17 to 21 (2,500 to 3,000) 28 to 41 (4,000 to 6,000) 48 to 55 (7,000 to 8,000) (13,000)

Technical Data Sheet

LOCTITE® Fixmaster® Magna-Crete®

December 2007

GENERAL INFORMATION

For safe handling information on this product, consult the Material Safety Data Sheet (MSDS).

Directions for use

1. Preparat ion: For best results, surface must be clean, dry and free from loose material. Remove all dirt, blacktop tar, and oil substances from the area to be covered, leaving a rough clean surface.

2. Forms: If forms are needed, use plastic or Formica.

3. Mixing: To mix material, add aggregate to activator and mix thoroughly. Add only enough activator to obtain the consistency desired for the application. Mix approximately 3.8 liters of activator to 20.4 kgs of aggregate (approximately 1 :5 ratio).

Material should be mixed immediately prior to placement and should be completed soon as possible.

4. Deep Pours: For repairs greater than 2.5 cm in depth, up to

13.6 kgs of dry pea gravel can be added for each 20.4 kgs of Magna-Crete® as a filler. Dry pea gravel should be added to the activator before the Magna-Crete® aggregate is mixed. For large applications, use HOT WEATHER MIX to manage the set time for additional working time.

5. Water: Work areas can be damp, however, standing water should be removed. Water should not be used to dilute the liquid or to adjust consistency of Magna-Crete®.

6. Cold Weather Application: Set-up time will be longer in colder applications. For those applications where the application temperature is less than 7 •c use COLD WEATHER MIX (one

0.45 kg package per 20.4 kgs of Magna-Crete® increases the cure speed by approximately 10 minutes) to accelerate the set time of the mixed material. Addition of the Winter additive should be made after the Magna-Crete has been thoroughly mixed, and just prior to the application or pouring of the Magna-Crete.

7. Warm Weather Application: For applications where the application temperature is greater than 29 •c, use HOT WEATHER MIX (one 0.45 kg package per 20.4 kgs of Magna Crete® decreases the cure speed by approximately 10 minutes) to manage the exothermic reaction and the working time of the mixed material. The Summer additive should be thoroughly mixed into the liquid portion of the Magna-Crete. The Magna Crete can then be mixed, and applied/poured.

8. Clean-up: Keep an adequate supply of water on hand to wash mixer and tools as soon as set begins 9 to 15 minutes at 20 •c.

Not for product specifications The technical data contained herein are intended as reference only.

Please contact your local quality department for assistance and recommendations on specifications for this product.

Or Government Approved Equivelent

TDS LOCTITE® Fixmaster® Magna-Crete®, December 2007

Storage Store product in the unopened container in a dry location. Storage information may be indicated on the product container labeling.

Optimal Storage: 8 •c to 21 •c. Storage below 8 •c or greater than 28 •c can adversely affect product properties. Material removed from containers may be contaminated during use. Do not return product to the original container. Henkel Corporation cannot assume responsibility for product which has been contaminated or stored under conditions other than those previously indicated. If additional information is required, please contact your local Technical Service Center or Customer Service Representative.

Conversions (°C x 1.8) + 32 = "F kV/mm x 25.4 = V/mil mm/ 25.4"' inches µm f 25.4"' mil N x 0.225"' lb N/mm x 5.71 "'lb/in N/mm2 x 145 "' psi MPa x 145 =psi N·m x 8.851 = lb·in N·m x 0.738 = lb·ft N·mm x 0.142 "'oz·in mPa·s =cP

Note The data contained herein are furnished for information only and are believed to be reliable. We cannot assume responsibility for the results obtained by others over whose methods we have no control. It is the user's responsibility to determine suitability for the user's purpose of any production methods ment!oned herein and to adopt such precautions as may be advisable for the protection of property and of persons against any hazards that may be involved in the handl"lng and use thereof. In fight of the foregoing, Henkel Corporation specifically disclaims all warranties expressed or implied, including warranties of merchant11bility or fitness for a particular purpose, arising from sale or use of Henkel Corporation's products. Henkel Corporation specifically discli"lims i"lny liability for consequential or incidental damages of any kind, including lost profits. The discussion herein of various processes or compositions is not to be interpreted as representation that they are free from domination of patents owned by others or as a license under any Henkel Corporation patents that may cover such processes or compositions. We recommend that each prospective user test his proposed application before repetitive use, using this data as a guide. This product may be covered by one or more United States or foreign patents or patent applications.

Trademark usage Except as otherwise noted, all trademarks in this document are trademarks of Henke! Corporation in the U.S. and elsewhere. ® denotes a trademark registered ln the U.S. Patent and Trademark Office.

Reference 1.6

Henkel Americas +860.571.5100

Henkel Europe +49.89.320800.1800

Henkel Asia Pacific +86.21.2891.8863

For the most direct access to local sales and technical support visit: www.henkel.com/industrial

JJ,@fTIT~

PRODUCT DESCRIPTION

LOCTITE® PC 9620 provides the following product characteristics:

Technoloay Magnesium phosphate-based Appearance Gray liquid to paste (mix to desired consistency) Cure Room temoerature cure after mixing Components Two component - requires mixing Aoolication Floorina & arout Specific Benefit • Easy to Use

• Applicator friendly

• Fast setting

• Cure temp.: -25 °C to +45 °C

LOCTITE® PC 9620 is a two-component, rapid setting concrete repair and grouting system that outperforms conventional concrete repairs. A high performance, magnesium phosphate-based system, LOCTITE® PC 9620 cures faster than concrete, and unlike concrete, bonds to both new and old concrete as well as most construction materials, including wood and steel. This product has smaller aggregate than LOCTITE® Fixmaster® MagnaCrete® and thus is suitable for shallower pours. Since LOCTITE® PC 9620 does not use a water additive, this repair system can be applied at virtually any temperature without shrinkage and is freeze/thaw and deicing salt resistant. This product is typically used for the repair of concrete highway walls, pot holes, airport runways, anchoring machinery, commercial refrigeration floors, loading docks, grouting bedplates and soleplates, columns and bridge decks, parking structure joints, concrete pillars, floor repairs, ramps, rai l grouting, anchoring bolts and handrails. This product is typically used in applications with an operating range of -26 °C to +1090 °c.

TYPICAL PROPERTIES

Coverage, 3.8 liter (1 gallon)

Coverage, 19 liter (5 gallon)

0.45 m• @ 0.64 cm thick/4.54 kg (4.8 rt• @ 0.25 in thick/10 lb)

2.0 m• @ 0.64 cm thick/20.4 kg (21 .6 ft2 @ 0.25 in thick/45 lb)

Technical Data Sheet

LOCTITE® PC 9620

Known as LOCTITE® Fixmaster® MagnaGrout®

August 2015

TYPICAL CURING PERFORMANCE

Set Time, ASTM C-807, minutes:

Initial Final

TYPICAL PERFORMANCE

Compressive Strength:

After 2 hours

After 3 days

After 28 days

After 1 year

GENERAL INFORMATION

N/mm2

(psi) N/mm2

(psi) N/mm2

(psi) N/mm• (psi)

3 to 11 15 to 22

17 to 21 (2,500 to 3,000) 28 to41

(4,000 to 6,000) 48to 55 (7,000 to 8,000) (13,000)

For safe handling information on this product, consult the Safety Data Sheet (SOS).

Directions for use:

1. Preparation: For best results, surface must be clean, dry and free from loose material. Remove all dirt, blacktop tar, and oil substances from the area to be covered, leaving a rough clean surface.

2. Forms: If forms are needed, use plastic or Formica.

3. Mixing: To mix material, add activator to aggregate and mix thoroughly. Add only enough activator to obtain the consistency desired for the application, approximately 1 :5 ratio of activator to aggregate. Material should be mixed immediately prior to placement and should be completed soon as possible.

4. Water: Work areas can be damp, however, standing water should be removed. Water should not be used to dilute the liquid or to adjust consistency of Magna Grout®.

5. Cold Weather Application : Set-up time will be longer in colder applications. Most applications can be open to traffic in 20 to 30 minutes (depending on ambient temperatures). e.g. 5 minutes at 32°C (90°F), 1 hour at -12°C (10°F).

6. Warm Weather Application: When using the 5 gallon kit, it is advisable to mix smaller batches at one time.

Mixing the entire 5 gallons may not give adequate working time and the product may set-up in the pail.

7. Clean-up: Keep an adequate supply of water on hand to wash mixer and tools as soon as set begins 9 to 15 minutes at 20 °C.

Not for product specifications The technical data contained herein are intended as reference only. Please contact your local quality department for assistance and recommendations on specifications for this product.

Storage Store product in the unopened container in a dry location.

Storage information may be indicated on the product container labeling.

Optimal Storage: 8 "C to 21 "C. Storage below 8 °C or greater than 28 "C can adversely affect product properties.

Material removed from containers may be contaminated during use. Do not return product to the original container. Henkel Corporation cannot assume responsibility for product which has been contaminated or stored under conditions other than those previously indicated. If additional information is required, please contact your local Technical Service Center or Customer Service Representative.

Conversions {°Cx1.8)+32=°F kV/mm x 25.4 = V/mil mm/ 25.4 = inches µm / 25.4 =mil N x 0.225 =lb N/mm x 5.71 =lb/in N/mm2 x 145 =psi MPa x 145 =psi N·m x 8.851 = lb·in N·m x 0.738 = Jb·ft N·mm x 0.142 =oz· in mPa·s = cP

Note:

The informalion provided in this Technical Data Sheet (TDS) including the recommendations for use and applica!lon of the product are based on our knowledge and experience of the product a sat the date of this TDS. The product can have a variety of different applicatlons as well as differing application and working condilions in your environment that are beyond our control. Henkel is, 1herefore, not liable for the suitability of our product for the production processes and condi!ions in respect of which you use them, as well as the intended applications and results. We strongly recommend that you carry out your own prior trials to confirm such suitability of our product.

Any liability ln respect of the information in the Technical Data Sheet or any other written or oral recommendalion(s) regarding the concerned product is excluded, except ii otherwise explicitly agreed and except in relation to death or personal injury caused by our negligence and any liability under any applicable mandatory product r1abi[!ty law.

Jn case products are dellvered by Henkel Belgium NV, Henkel Electronic Materials NV, Henkel Nederland BV, Henkel Technologies France SAS and Henkel France SA please addltlonally note the following:

Jn case Henkel would be nevertheless held liable, on whatever legal ground, Hankel's liability will in no event exceed the amount of the concerned delivery.

tn case products are delivered by Henkel Colornbiana, s.A.S. the following disclaimer ls applicable;

The information provided in this Technical Data Sheet (TDS) including the recommendations for use and applica!fon of the product are based on our knowledge and experience of the product as at the date of this TDS. Henkel Is, lherefore, not liable for the suitability of our product for the production processes and conditions in respect of which you use them, as well as the Intended applications and results. We strongly recommend that you carry out your own prior trials to confirm such suitability of our product.

Any liability In respect of\he information in the Technical Data Sheet or any other wrillen or oral recommendation(s) regarding the concerned product is excluded, except If otherwise explicitly agreed and except in relation to dealh or personal Injury caused by our negligence and any liability under any applicable mandatory product liabil~y law.

In case products are delivered by Henkel Corporation, Resin Technology Group, Inc., or Henkel Canada Corporation, the following disclaimer Is applicable:

The data contained herein ere furnished for information only and are believed to be reliable. We cannot assume responsibility for the results obtained by others

TDS LOCTITE® PC 9620, August 2015 over whose methods we have no control. It fs the user's responsibility lo determine suitability for the user's purpose of any production methods mentioned herein and to adopt such precautions as may be advisable for the proteciion of property and of persons against any hazards that may be involved in the handling and use thereof. In light of the foregoing, Henkel Corporation specifically disclaims all warranties expressed or implied, including warranties of merchantability or fitness for a partlcufar purpose, arising from sale or use of Henkel Corporation's products. Henkel Corporation speclflcally disclaims any liabUlty for consequenllal or Incidental damages of any kind, Including lost profits. The discussion herein of various processes or compositions is not to be interpreted as representation that they are free from domination or patents owned by others or as a l!cense under any Henkel Corporation patents that may cover such processes or compositions. We recommend that each prospective user test his prOposed application before repetitive use, using this data as a guide. Th!s product may be covered by one or more United Slates or foreign patents or patent applications.

Trademark usage Except as otherwise noted, all trademarks in this document are trademarks of Henkel Corporation in the U.S. and elsewhere. ® denotes a trademark registered in the U.S. Patent and Trademark Office.

Reference 0.1

Henkel Americas +860.571.5100

Henkel Europe +49.89.320800.1800

Henkel Asia Pacific +86.21.2891.8859

Developmental Sample Laboratory Data Sheet ll@<CTIT£ Fixmaster Crack Filler SL

PRODUCT DESCRIPTION

LOCTITE® Crack Filler SL is a two component, rapid curing 1 :1 ratio, Polyurea joint filler designed for heavy duty traffic and freezer applications. It is a self leveling, 100% solids, low viscosity, flexible system that provides 10-1 5% movement of installed joint width. Can be applied at temperatures between -40°F - 120°F

TYPICAL APPLICATIONS

May be used to fill interior control joints or new construction saw joints on horizontal concrete surfaces.

Designed for industrial floor applications receiving heavy vehicle traffic and can be used in exterior applications where minimal joint movement from thermal cycling will occur.

PROPERTIES OF UNCURED MATERIAL

Resin

Chemical Type Appearance Viscosity@ 25•c. mPa.s (cP)

Hardener

Chemical Type Appearance Viscosity@ 25•c. mPa.s (cP)

Mixture

Appearance Mix Ratio (R:H) By Volume

Typical Value Isocyanate

Amber

Typical Value Amine Gray

Typical Value Concrete Gray

1 :1

TYPICAL PROPERTIES OF CURED MATERIAL

Physical Properties Description of curing parameters

Tensile strength (psi) Elongation(%) Hardness (Shore A) Gel Time (min)

Property

Cure Time -100 gram mass (min) Adhesion to Concrete (psi) Shelf Life (months)

Typical Value 1,200

75-80

1/30/2009

CONSIDERATIONS:

• LOCTITE® Crack Filler SL is not intended for joints that are subject to higher than 10-15% movement.

• LOCTITE® Crack Filler SL is a moisture sensitive product and cannot be applied to wet or damp joints.

JOINT PREPARATION:

Remove all dust, debris, oil and any other contamination from the construction and/or saw cut joints. For best results re-cut joints with a dry diamond blade (do not apply to a wet surface). Applied material should be level with concrete. Allow LOCTITE® Crack Filler SL to set for approximately 45 minutes (at 75° F.) then use a sharp 8" wall scraper to shave excess material from top of slab.

CARTRIDGE SET-UP:

While preparing cartridge for dispensing, keep cartridge in an upright position to prevent material from leaking out of cartridge. Do not tilt cartridge until material is to be dispensed.

I. Shake cartridge vigorously for 45 seconds. Then let cartridge stand upright for 5 minutes.

II. Remove plastic cap from the top of the cartridge.

III. Immediately place the nozzle onto cartridge and secure with nut by threading in a clock-wise direction.

Make sure that the nozzle and cartridge assembly is secure.

IV. Insert cartridge with nozzle attached into dispenser.

Make sure it is properly positioned with shoulder of cartridge flush with front/top bracket of the dispenser.

With nozzle pointing straight up, slowly apply pressure to dispenser to purge air from cartridge and nozzle.

Once air has been purged, continue holding straight up and balance the cartridge by dispensing V2 stroke of material into a rag (1-2 quick bursts if using an air tool).

After purging and balancing always point cartridge downward when not dispensing to prevent mixed material in he nozzle from flowing back into the cartridge.

Henkel Corporation, 1001 Trout Brook Crossing, Rocky Hill, CT 06067, U.S.A. 8 Technologies Loctite is a Registered Trademark of Henkel Corporation U.S.A. 860.571.5100

Repairing Small Joints and/or Cracks in Concrete:

V. Place the mixing nozzle directly over the crack or joint you are repairing. Dispense material and allow to gravity feed into the crack/joint. Over-fill the crack/joint so that material is slightly higher than the face of the concrete slab you are repairing.

VI. Allow the LOCTITE® Crack Filler SL to set for approximately 45 minutes then use a sharp 8" wall scraper to shave excess material from top of slab.

VII. Allow material to fully cure before subjecting repaired area to any type of traffic.

USE AND APPLICATION

This product is not recommended for use in pure oxygen and/or oxygen rich systems and should not be selected as a sealant for chlorine or other strong oxidizing materials.

For safe handling information on this product, consult the Material Safety Data Sheet (MSDS).

Storage Store product in cool, dry location, in unopened containers at a temperature between 16°C and 32°C (60°F to 90°F) unless otherwise labeled. Optimal storage is at the lower haff of this temperature range. To prevent contamination of unused product, do not return any material to lts original container. For further specific shelf life information, contact Application Engineering at (860) 571-5100.

Data Ranges The data contained herein may be reported as a typical value and/or range. Values are based on actual test data and are verified on a periodic basis.

Note The developmental product for which the data provided herein are furnished for informational purposes only and are believed to be accurate and reliable. Nevertheless, Henkel Corporation cannot and will not assume responsibility for the results obtained by others over whose production methods we have no control. Thus, it is the user's responsibility to determine the suitability of this developmental product for the user's purpose of any production methods mentioned herein and to adopt such precautions as may be advisable for the protection of property and of persons against any hazards that may be involved in the handling, storage, disposal and use thereof. In light of the foregoing, HENKEL CORPORATION

SPECIFICALLY DISCLAIMS ANY AND ALL WARRANTIES

Loctite Industrial

LOS Flexible Crack Filler

EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF

MERCHANTABILITY, FITNESS FOR A PARTICULAR

PURPOSE AND FREE FROM CLAIMS OF THIRD PARTY

PATENT INFRINGEMENT, ARISING FROM THE SALE,

POSSESSION, HANDLING, STORAGE, DISPOSAL,

TRANSPORTATION OR USE OF THIS DEVELOPMENTAL

PRODUCT . HENKEL CORPORATION SPECIFICALLY

DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR

INCIDENT AL DAMAGES OF ANY KIND, INCLUDING LOST

PROFITS. Neither the developmental product, nor the data or discussion herein of various processes for which, are to be interpreted as an express or implied license under any Henkel Corporation patents. Henkel Corporation recommends that any and all proposed commercial application(s) using this developmental product be evaluated for reproducibility in the exact manner and on the production equipment with which it is intended to be used before repetitive commercial production use, using this data as a guide. This developmental product may be covered by one or more United States or foreign patents or patent applications of Henkel Corporation, or under which Henkel Corporation is licensed.

IL@<CT/TE, Henkel Loctite Corporation, 1001 Trout Brook Crossing, Rocky Hill, CT 06067, U.S.A.

Loctite is a Trademark of Henkel Loctite Corp. U.S.A. 860.751.5100 www.loctite.com

Technical Data Sheet

IL@<CTIT£ Fixmaster® Anchor Bolt Grout

PRODUCT DESCRIPTION

Fixmaster® Anchor Bolt Grout provides the following product characteristics:

Technology Epoxy Chemical Type Epoxy Appearance (Resin) White paste Appearance (Hardener) Black paste Appearance (Mixed) Grey paste Components Two component - requires mixing Mix Ratio, by volume - 1 : 1 Resin : Hardener Mix Ratio, by weight - 100 : 80 Resin : Hardener Cure Room temperature cure after mixing Aoolication Groutina Application Temperature 5 to 45 °C

Fixmaster® Anchor Bolt Grout is a two component, 100% solids epoxy designed to anchor threaded rod, bolts, rebar dowels and smooth dowels into concrete, grout filled block, and other non reinforced masonry. Typical applications include seismic anchoring and bracing, grouting dowel bars and tie bars for full-depth concrete pavement repairs, capping paste for crack injection, and pick proof sealant (windows.doors, locks, correctional facilities). Fixmaster® Anchor Bolt Grout should not to be used for long term sustained loads.

TYPICAL PROPERTIES OF UNCURED MATERIAL

Resin:

Density @ 25 •c, g/ml Viscosity, Brookfield, 25 •c, mPa·s (cP)

Flash Point - See MSDS

Hardener:

Density @ 25 •c. g/ml Viscosity, Brookfield, 25 •c, mPa·s (cP)

Flash Point - See MSDS

Mixed:

Working Time @ 25 •c, minutes

TYPICAL CURING PERFORMANCE

Curing Properties Cure Time @ 25 •c, hours

1.54tO1.74LMS 200,000 tO 240,000LMS

1.39 tO 1.75LMS 210,000 tO 25Q,000LMS

February 2008

Working Life

Ill GI -::s 50 c: 40 e ~ a; 30 ............ E r--..... j:: 20 r--..__

10 -0 0 5 10 15 20 25 30

Temperature, °C

Cure Time

2 ·1 """ Ill "' ::s 14 0 "\ .l:

a; 7

I'\. E j:: 6~ ·

'l\. e 3 ::s

0 - 0 5 10 15 20 25 30

Temperature, °C

TYPICAL PROPERTIES OF CURED MATERIAL

Cured @ 22 •c for 24 hours Physical Properties:

Compressive Strength, at failure, ISO

Cured @ 25 •c, for 7 days Physical Properties:

Tensile Strength, ISO 527-2

Compressive Strength, at yield, ISO Compressive Modulus, ISO 604

Elongation, at failure, ISO 527-2, %

Nlmm• (psi)

Nlmm2

(psi) Nlmm2

(psi) Nlmm• (psi)

35 40

35 40

;::49tMS (2:7,100)

(7,400) (11,900) 1,390 (201,300) 1.8

Water Absorption, ISO 62, o/o:

24 hours in water@22 °C

Linear Shrinkage, ISO 1675 %

Cured for 2 days @ 25 'C Physical Properties:

Bond Strength, ASTM-C882

Cured for 14 days @25 •c Physical Properties:

Bond Strength, ASTM-C882

Nfmrn2

(psi)

Nfmm' (psi)

0.52 0.4

(1,410)

(2,340)

TYPICAL PERFORMANCE OF CURED MATERIAL

Tension Load (1f2"), ASTM E488 N 62,870 112" threaded rod at *90 in 3,000 psi (lb) (14,150) concrete.

•90 is the ernbedment depth of the anchor (9X1/2"); in this example, a 1/2" threaded rod embedded 4-1/2" in 3,000 psi concrete.

GENERAL INFORMATION

This product is not recommended for use in pure oxygen and/or oxygen rich systems and should not be selected as a sealant for chlorine or other strong oxidizing materials

For safe handling information on this product, consult the Material Safety Data Sheet (MSDS).

Directions for use

1. Drill hole to desired diameter and depth. Clean out the hole and brush with a bristle brush. Blow out the remaining dust from the bottom of the ho!e and ensure that the surface is clean and dry.

2. Remove plastic cap and plugs from the cartridge. Dispense a small amount of adhesive to ensure that both black and white materials flow freely and evenly from the cartridge.

3. Attach mixing nozzle to cartridge and dispense a small amount of adhesive into a waste container.

4. Fill holes 1/2 to 3/4 full by dispensing adhesive, beginning at the bottom of hole.

5. Insert the anchor bolt, threaded rod or rebar to the bottom of the hole while turning clockwise.

6. Do not touch or bolt-up unfll the recommended adhesive cure time has passed.

Loctite Material SpecificationlM• LMS dated January 22, 2008. Test reports for each batch are available for the indicated properties. LMS test reports include selected QC test parameters considered appropriate to specifications for customer use. Additionally, comprehensive controls are ln place to assure product quality and consistency. Special customer specification requirements may be coordinated through Henkel Quality.

TDS Fixmaster® Anchor Bott Grout, February 2008

Storage Store product in the unopened container in a dry location.

Material removed from containers may be contam'1nated during use. Do not return liquid to original container. Storage information may be indicated on the product container labeling.

Optimal Storage: 8 °C to 21 °C. Storage below 8 °C or greater than 28 °C can adversely affect product properties.

Henkel cannot assume responsibility for product which has been contaminated or stored under conditions other than those recommended. Jf additional information is required, please contact your local Technical Service Center or Customer Service Representative.

Conversions (°Cx1.8)+32=°F kV/mm x 25.4 = V/mif mm/ 25.4 = inches µm / 25.4 =mil N x 0.225 =lb N/mm x 5.71 =lb/in N/mm2 x 145 =psi MPa x 145 =psi N·m x 8.851 = lb·in N·m x 0.738 = lb·ft N·mm x0.142 = oz·in mPa·s = cP

Note The data contained herein are furnished for information only and are believed to be reliable. We cannot assume responsibility for the results obtained by others over whose methods we have no control. It is the user's responsibility to determine suitability for the user's purpose of any production methods mentioned herein and to adopt such precautions as may be advisable for the protection of property and of persons against any hazards that may be involved in the handling and use thereof. In light of the foregoing, Henkel Corporation specifically disclaims all warranties expressed or implied, including warranties of merchantability or fitness for a particular purpose, arising from sale or use of Henkel Corporation's products. Henkel Corporation specifically disclaims any liability for consequential or incidental damages of any kind, including Jost profits. The discussion herein of various processes or compositions is not to be interpreted as representation that they are free from domination of patents owned by others or as a license under any Henkel Corporation patents that may cover such processes or compositions. We recommend that each prospective user test his proposed application before repetitive use, using this data as a guide. This product may be covered by one or more United States or foreign patents or patent applications.

Trademark usage Except as otherwise noted, all trademarks in this document are trademarks of Henkel Corporation in the U.S. and elsewhere. ® denotes a trademark registered in the U.S.

Patent and Trademark Office.

Reference 0.1

Henkel Americas +860.571.5100

Henkel Europe +49.89.320800.1800

Henkel Asia Pacific +86.21.2891.8863

Technical Data Sheet

!L@((T/T£ LOCTITE® Big Foot™ Acrylic Pedestrian Grade

PRODUCT DESCRIPTION

LOCTITE® Big Foot™ Acrylic Pedestrian Grade provides the following product characteristics:

Technology Acrylic Appearance Thick gray liquid Components One component - requires no mixing Cure Room temperature cure Application Non-slip coating Specific Benefit • Easy to Use

• Resistant to weathering

• Reduces accidents (slips and falls) in the workplace

LOCTITE® Big FooPM Acrylic Pedestrian Grade is an elastomeric non-slip floor and deck coating that is designed for pedestrian traffic. Typical applications include a non-slip finish for steel ramps, concrete, walkaways, loading docks, marine applications, assembly areas, and stairs where a flexible non-slip coating is required. This product is typically used in applications with an operating range of -29 •c to +60 ·c.

TYPICAL PROPERTIES OF UNCURED MATERIAL

Viscosity@ 25°C, mPa·s (cP) Volume of Solids. % voe. ASTM D 3960, g/I Weight Per Gallon, lbs/gal Coverage:

Roller Spray

Flash Point - See MSDS

TYPICAL CURING PERFORMANCE

Curing Properties Dry time @ 21 •c, hours:

Heavy pedestrian traffic Light pedestrian traffic

8,000 to 12,000' "5

40.7 14.1to14.9~Ms

6.5 m2 per 3.78 I 11.6m2 per3.78 1

TYPICAL PROPERTIES OF CURED MATERIAL

Cured @ 21 •c except where noted

Physical Properties:

Coefficient of friction , ASTM F 609:

Dry 1.3 Wet 0.9

July 2008

GENERAL INFORMATION

This product is not recommended for use in pure oxygen and/or oxygen rich systems and should not be selected as a sealant for chlorine or other strong oxidizing materials

For safe handling information on this product, consult the Material Safety Data Sheet (MSDS).

Directions for use:

1. Surface Preparation:

For coating concrete. wood, tile. and other porous surfaces, please refer to the Loctite® Big Foot™ Acrylic Primer Technical Data Sheet.

For coating metal surfaces, please please refer to the Loctite® Big Foot™ Metal Primer Technical Data Sheet.

Note: The use of a primer will increase the adhesion and durability of LOCTITE® Big Foot™ Acrylic Pedestrian Grade

2. Mixing:

Thoroughly premix contents of resin can, with a mechanical mixer. using Loctite® Big Foot™ Mixer Blades, scraping material from sides and bottom of the can until mixed material assumes a uniform color and appearance.

3. Application Method:

LOCTITE® Big Foot™ Acrylic Pedestrian Grade can be applied at surface temperatures of 10 to 54°C. Application is not recommended when the surface temperature is above or below these temperatures. It can be applied by roller or spray.

4. Roller Rolled applications provide the most aggressive anti-slip characteristics with an irregular, ridged profile.

1. Use a phenolic roller. It is important that the rolled profile expose the maximum amount of anti-slip aggregate. If aggregate is not properly exposed, the coating may become slippery when wet.

2. Pour a "ribbon" of material on the surface approximately 60 cm x 15 cm. Roll material toward you with a moderate amount of pressure. Do not over-roll too many times or press down too heavily. Be careful that material does not build up too thickly along welds (roll across welds not along them). Material applied too thickly may not cure properly.

3. Higher temperatures will shorten drying time and conversely, lower temperatures and high relative humidity will lengthen drying time. Exterior applications must be protected from rain for at least 12 to 24 hours after application. Protect from heavy or extended exposure to water, oil and chemicals for 5 to 7 days during final cure.

5. Spray:

Spray applications will result in a uniform appearance with good non-slip characteristics.

1. LOCTITE® Big Foot™ Acrylic Pedestrian Grade should be thinned. Thinning will result in grit not remaining properly ln suspension.

2. Specialized mastic type spray equipment is required. A recommended set-up is as follows:

A. A 19 liter outlet pressure tank equipped with a double regulator and an air driven agitator, and 2.5 cm LD.

outlet pipe.

B. 7.6 m of .95 cm air hose with .95 cm female connectors at each end.

C. 7.6 m of1.9 cm air hose with 1.9 cm female connectors at each end.

D. A Binks Model 7E2 spray gun equipped with .64 cm (#45) fluid nozzle and a .64 cm internal air cap or a Binks Model 52-2012 (1.2 m) pole gun equipped with the same fluid nozzle and air nozzle ..

3. Minimum air supply required is 20 CFM at 90 lbs.

pressure. Recommended is 15 to 20 psi on material and 20 to 25 psi on atomization. Always keep atomization air pressure higher than pot pressure. Keep agitator running slowly. Good coverage and film thickness will be obtained working at 45 to 60 cm from the surface.

Overlap strokes about 50°/o. Make sure of application.

Very tittle abrasive rebound will be noticed at 15 psi, however, it wm be more noticeable at higher pressure.

4. When temperature is above 26°C, it is advisable to flush the spray equipment with water every hour or so in order to prevent the possibility of any material setting up and plugging the equipment.

6. Surface Maintenance - Maintain a clean surface to ensure that the anti-slip safely performance is maximized. We recommend the following cleaning procedure:

1. Apply an all-purpose, biodegradable cleaner/degreaser.

2. Scrub surface with a long-handled, fibre bristled brush or floor machine.

3. Rinse with clean water and dry. Foreign matter such as chewing gum should be removed with a scraper or putty knife and then the surface should be cleaned following above procedure.

4. Although this anti-slip coating is extremely durable, it is not permanent and will require occasional touch-up, especially in high traffic areas. This material can be re-applied over itself. To re-apply, follow instructions above for surface preparation, mixing and application.

Loctite Material SpecificationL~s LMS dated April 04, 2002. Test reports for each batch are available for the indicated propertles. LMS test reports include selected QC test parame1ers considered appropriate to specifications for customer use. Additionally, comprehensive controls are in place to assure product quality and consistency. Special customer specification requirements may be coordinated through Henkel Quality.

TDS LOCTITE® Big Foot™ Acrylic Pedestrian Grade , July 2008

Storage Store product in the unopened container in a dry location.

Material removed from containers may be contaminated during use. Do not return liquid to original container. Storage information may be indicated on the product container labeling.

Optimal Storage: 8 °C to 21 °C, Storage below 8 °C or greater than 28 "C can adversely affect product properties.

Henkel cannot assume responsibillty for product which has been contaminated or stored under conditions other than those recommended. If additional information is required, please contact your local Technical Service Center or Customer Service Representative.

Conversions (°C x 1.8)+ 32= 0 f kV/mm x 25.4 = V/mil mm 125.4 =inches µm/25.4 =mil N x 0.225 =lb N/mm x 5.71 =lb/in N/mm2 x 145 =psi MPa x 145"" psi N·m x 8.851 = lb·in N·m x 0.738 = lb·ft N·mm x 0.142 = oz·in mPa·s = cP

Note The data contained herein are furnished for information only and are believed to be reliable. We cannot assume responsibility for the results obtained by others over whose methods we have no control. It is the user's responsibility to determine suitability for the user's purpose of any production methods mentioned herein and to adopt such precautions as may be advisable for the protection of property and of persons against any hazards that may be involved in the handling and use thereof. In light of the foregoing, Henkel Corporation specifically disclaims all warranties expressed or implied, including warranties of merchantability or fitness for a particular purpose, arising from sale or use of Henkel Corporation's products. Henkel Corporation specifically disclaims any liability for consequential or incidental damages of any kind, including lost profits. The discussion herein of various processes or compositions is not to be interpreted as representation that they are free from domination of patents owned by others or as a license under any Henkel Corporation patents that may cover such processes or compositions. We recommend that each prospective user test his proposed application before repetitive use, using this data as a guide. This product may be covered by one or more United States or foreign patents or patent applications.

Trademark usage Except as otherwise noted, all trademarks in this document are trademarks of Henkel Corporation in the U.S. and elsewhere. ® denotes a trademark registered in the U.S.

Patent and Trademark Office.

Reference 0.2

Henkel Americas Henkel Europe Henkel Asia Pacific +860.571.5100 +49.89.320800.1800 +86.21.2891 .8863

IL@<CTITE

1001 Trout Brook Crossing Rocky Hill, CT 06067-3910 Telephone: {SliO) 571-5100

FAX: (860) 571-5465

PRODUCT DESCRIPTION

Loctite® Extend® Rusi Treatment is a fast drying, milky white latex coating that is applied to rusted metal to stop rust, protect the surface and act as a primer for the finish coat.

TYPICAL APPLICATIONS

• Pipes and valves, fittings in refineries, tankers, power plants, domestic and commercial heating/cooling plants

• Trucks, trailers, storage tanks

• Fences, guard rails, conveyors, supports

• Overhead cranes, booms, floor gratings, ductwork

• Outdoor advertising sign supports/frames, municipal and highway sign posts and frames

• Bulkheads, overheads, decks, hatch covers, stacks on ships (topcoat with appropriate marine plant)

• Agricultural equipment, harvesters, plows, discs, tractors, corn plckers, etc.

• Snow removal equipment in highway department maintenance yards

• Paper mills, chemical plants, steel mills, utf!itles for maintenance of pipes, tanks, support steel, valves

• Castings and stampings before final machining

TYPICAL PROPERTIES OF UNCURED MATERIAL

Chemical Type Appearance Odor Specific Gravity Viscosity Flash Point, TCC

HEAT AGING

Synthetic latex resin Milky liquid

Mild 1-20

Flow similar to SAE 40 Motor Oil None - aqueous medium

Resists heat aging up to 200°F continuously. Useful properties up to 250°F, for short exposure periods.

TYPICAL ENVIRONMENT AL RESISTANCE

Loctite® Extend® Rust Treatment is satisfactory for exterior exposure without a topcoat in mild environments. Two coats maximum are recommended. A 7 to 14 day drying and curing time is recommended. For severe environments, a suitable topcoat is required.

USE AND APPLICATION

Surlace Preparation

1. Old Steel:

Loose or "flaky" rust must be removed. Only conversion of firmly bonded rust will result in durable protection_ OH, grease, old paint, mill scale, form oil, fingerprints and water soluble surfaces and chlorides must be removed to aHow Loctite® Extend® Rust Treatment to react with rust.

Loose rust, mill scale and oil paint should be removed preferably by power wirebrushing, followed by rinsing with water to remove powder and solubles. Manual wirebrushing, chipping, scraping and particularly rotopeening can also be used. Oil, grease, form oil and fingerprints should be removed before loose rust. Ideal surfaces will show light rust as well as bare metal surfaces.

Product Description Sheet

Extend® Rust Treatment

Maintenance, Repair & Operations, March 2006

2. Rust Conversion Time and App(!arance:

Two coats of Loctite® Extend® Rust Treatment are recommended.

On llghtly rusted steel (that has been wirebrushed), the first coat will start to develop a violet color within 60 seconds. This will become satin to flat black in appearance. The second coat should dry to a satin black appearance.

On heavily rusted steel (that has been wirebrushed), the first coat should develop a purple-black color within seconds. The second coat should dry to a black color with gloss varying from flat to satin. The second coat should be applied within 15 to 30 minutes of the first coat.

Directions for Use 1 Mix thoroughly before using.

2. Remove oil, dirt and grease from surface. Wire brush to remove flaky rust and loose scale. Some surface rust must be present

3. Pour into clean container for easy application by brushing or apply directly to surface and brush out.

4. Use of gloves is recommended.

5. Brush or sponge on liberally. An airless spray may also be used.

6. A black coating will appear within 5 minutes. Uneven color indicates need for additional coats for maximum protection. Recoat time 15 to 30 minutes. Allow 24 hours minimum to dry before finish paint.

7. Most finish paints will not require any additional primer.

However, light color latex and metal filled paints reguire a solvent base primer on top of Loctite® Extend® Rust Treatment coating before finish application.

8. Brushes, rollers and other tools should be cleaned immediately with detergent and water. Flush spray equipment immediate!y after use with detergent and water.

Loctite® Extend® Rust Treatment is difficult to remove when dry.

Hints and Precautions for Use

1. Surface preparation - remove loose or flaky rust, oil, grease, dirt, oil debonding paint, water soluble sulfates, chlorides, cutting oil residues.

2. If sandblasted, sufficient material should be applied to effectively cover the profile.

3. Application of 2 coats for 4 mils dry film thickness recommended for maximum durability.

4. Prolonged contact with water before fully cured may cause coating to turn white. After re-drying black appearance will return.

Application Conditions Loctite® Extend® Rust Treatment may be applied when surface and air is between 50°F minimum and rising and 90°F maximum and falling. Reaction is slower at lower temperatures. If temperature is too hot, film may surface dry and bubble. High humidity is beneficial; it slows drying but assists rust conversion. Loctite® Extend® Rust Treatment should not be applied in conditions of condensing humidity (e.g. fog, dew), on ice, in rain or in heavy sea (salt) spray atmospheres. Steel surfaces may be damp but not wet (i.e.

continuous visible film of water). Do not apply Loctite® Extend® Rust Treatment to surfaces in direct sunlight.

NOT FOR PRODUCT SPECIF1CAT10NS.

THE TECHNICAL DATA CONTAINED HEREIN AREJNTENOEDAS REFERENCE ONLY.

PLEASE CONTACT LOCTITE CORPORATION QUALITY OEPARTMENT FOR ASSISTANCE AND RECOMMENDATIONS ON SPECIFICATIONS FOR THIS PRODUCT.

ROCKY HILL, CT FAX: +1 {a60)·S71·5473 DUBLIN, IRELANO FAX: +35~-{1}--451. 99~9

Application Equipment Methods Loctite® Extend® Rust Treatment may be applied by brush, roller or spray. Brush or roller is suitable for small areas.

Avoid sags and ridges and keep wet by coating about a square yard at a time. Roll away from previously coated area then roll back. Do not pour unused material back into the original container or dip brushes in original container. NEVER add solvents to Loctite® Extend® Rust Treatment Spray application is recommended for larger areas. Airless spray equipment is faster and provides more effective conversion due to improved surface penetration. Conventional air-spray equipment may be used, but Loctite® Extend® Rust Treatment may require thinning up to 1 Oo/o with water for proper spraying.

Resistance to Moisture Solvents & Chemicals Loctite® Extend® Rust Treatment should be topcoated for many applications. Continuous exposure of Loctite® Extend® Rust Treatment coating to water, solvents or chemicals can cause whitening, blistering or flaking of the latex film.

Loctite® Extend® Rust Treatment should not be used in applications involving continuous immersion in water or fluids.

Loctite® Extend® Rust Treatment should be topcoat&! with products known to be resistant to the environment expect&!.

Latex topcoats are not recommended without a suitable barrier coat.

Topcoat selection is dependent upon the environment to which the coating will be subjected. The following guidelines can be used. Topcoats are listed by their relative order of performance.

' Moisture/salt spray - high-build epoxies, coal tar epoxies, catalyzed urethanes, vinyls, chlorinated rubber Solvent Resistance - catalyzed urethanes, high build epoxies, coal tar epoxies, vinyls Acid Resistance - catalyzed urethanes, vinyls, coal tar epoxies, high build epoxies Alkali Resistance - catalyzed urethanes, coal tar epoxies, high build epoxies, chlorinated rubber Oxidizing Agent Resistance - vlnyls, catalyzed urethanes Abrasion - epoxies, urethanes, alkyds

Where cratering, pitting or heavy surface profile is evident, use two coats of Loctite® Extend® Rust Treatment by a high build primer or topcoat with sufficient mil thickness to prevent pin point corrosion. As with all paint systems, a test patch Is recommended. Any reputable painting contractor or coating representative can also assist you.

The following primers should not be applied directly over Loctite® Extend® Rust Treatment

• Zinc dust (zinc rich primers)

• Copper powder (anti-fouling paints)

• Industrial primers containing chromate are usually compatible, however a test patch should be completed to insure performance.

Clean Up When Loctite® Extend(!) Rust Treatment dries, it is extremely difficult to remove; therefore, spatters should be cleaned as they occur. Immediately after use, contaminated brushes, rollers, trays, etc., should be clean&! with cold tap water and detergent. Spray equipment should be flushed through immediately with mild detergent and water and rinsed with fresh water. Containers should be closed after every use to prevent skinning.

PDS Extend Rust Treatment, March 2006

If Loctite® Extend® Rust Treatment is spilled on clothes, the garment should be soaked with cold tap water as soon as possible and Loctite® Extend® Rust Treatment washed out before it dries. Do not use ammonia, strong alkali detergents or hot water for clean up.

Hands and naifs should be cleaned with soap and water using a nail brush. Black stains from iron-contaminated Loctite Extend® Rust Treatment can be removed from the hands with a mixture of 1 volume of liquid household bleach and 4 volumes of tap water, followed by washing with soap and water. Spills of Loctite® Extend® Rust Treatment should be flushed with large amounts of cold tap water.

Remo vat Once dried, strong solvents such as paint remover wm be required to remove Loctite'" Extend® Rust Treatment from equipment and clothes.

Mechanical abrasion may be necessaiy.

GENERAL INFORMATION

This product is not recommended for use in pure oxygen and/or oxygen rich systems and should not be selected as a sealant for chlorine or other strong oxidizing materials.

For safe handling information on this product, consult the Material Safety Data Sheet, (MSDS).

V\lhere aqueous washing systems are used to clean the surfaces before bonding, it is important to check for compatibility of the washing solution with the adhesive. In some cases these aqueous washes can affect the cure and performance of the adhesive.

This product is not nonnally recommended for use on plastics (particularly thennoplastic materials where stress cracking of the plastic could result). Users are recommended to confirm compatibility of the product with such substrates.

Orderin!l Information Item Number Container Size

75430 1 qt. Bottle 75448 1 gal. Bottle 75465 5 aal. Pail

Storage Store material in original container. Store between 6° to 28°C (46° to 62°F). Protect from freezing. When stored under these conditions, a one year shelf life may be expected. TO PREVENT

CONTAMINATION OF UNUSED MATERIAL, DO NOT RETURN ANY

PRODUCT TO ITS ORIGINAL CONTAINER. KEEP CONTAINERS

TlGHTL Y CAPPED.

Data Ranges The data contained herein may be reported as a typical value and/or range. Values are based on actual test data and are verified on a periodic basis.

Note The data contained herein are furnished for information only and are believed to be reliable. We cannot assume responsibility for the results obtained by others over whose methods we have no control. it is the user's responsibility to detennine suitability for the user's purpose of any production methods mentioned herein and to adopt such precautions as may be advisable for the protection of property and of persons against any hazards that may be involved in the handling and use thereof. In light of the fQregoing, Loctite Corporation specifically disclaims all warrantieS expressed or implled, Including warranties of merchantability or fitness for a particular purpose, arising from sale or use of Loctite Corporation's products. Loctite Corporation specifically disclaims any liability for consequential or incidental damages of any klnd, including lost profits.

This is the start of the file's text. The full file is on GovTribe.