Bldg-503PB_WO53153.xlsx

XLSX spreadsheet 52 KB Posted

Attached to
Bldg. 503 Repair/Minor Const/Equipment Federal contract opportunity
Solicitation number
FA8201-16-B-0009
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Hill Air Force Base

About this file

Bldg. 503 PB (lead paint survey).

View the file

Other files for this federal contract opportunity

Other files attached to Bldg. 503 Repair/Minor Const/Equipment, newest first.
File Type Posted
IFB_B503_Amend_04.docx DOCX document
TECHNICAL_NOTESa.docx DOCX document
2ndSiteVistSigninSheets.pdf PDF
B503KRSM092001-E4.0BLD_503_REPAIRS-E4.0.pdf PDF
5600_System_CS23_GHD582_0516 —
503 Individual Pictures 98.pdf PDF
503 Individual Pictures 68.pdf PDF
503 Individual Pictures 95.pdf PDF
503 Individual Pictures 58.pdf PDF
503 Individual Pictures 82.pdf PDF
503 Individual Pictures 94.pdf PDF
200_Anti_Skid_Additive_CS37_GDH82_715.pdf PDF
503 Individual Pictures 96.pdf PDF
LS-102.pdf PDF
503 Individual Pictures 92.pdf PDF
A_INTRODUCTION.docx DOCX document
MaterialsEstimate.docx DOCX document
Manufdata1s.pdf PDF
503 Individual Pictures 106.pdf PDF
503 Individual Pictures 64.pdf PDF
503 Individual Pictures 102.pdf PDF
503 Individual Pictures 73.pdf PDF
503 Individual Pictures 87.pdf PDF
503 Individual Pictures 65.pdf PDF
503 Individual Pictures 55.pdf PDF
Seed_Mix.pdf PDF
503 Individual Pictures 72.pdf PDF
503 Individual Pictures 57.pdf PDF
503 Individual Pictures 109.pdf PDF
RAMP_DETAIL.pdf PDF
Photo_Notes1.docx DOCX document
503 Individual Pictures 83.pdf PDF
503 Individual Pictures 69.pdf PDF
INDsupplyQuote.pdf PDF
503 Individual Pictures 66.pdf PDF
Contractor_Questions_ _Answers_-_26_Oct_2016.pdf PDF
503 Individual Pictures 53.pdf PDF
503 Individual Pictures 104.pdf PDF
Manufdata1.pdf PDF
503 Individual Pictures 103.pdf PDF
503 Individual Pictures 107.pdf PDF
7400_System_450_VOC_Primers_RO11_GDH1090.pdf PDF
503 Individual Pictures 85.pdf PDF
B503_Amend_02.docx DOCX document
BLDG._503_EXTERIOR_UPGRADE_SET_sow.pdf PDF
K092001-B503_Specifications_Rev_7.25.16.docx DOCX document
Storm_Water_Pollution_Prevention_Plan_Building_680_KRSM_152043.pdf PDF
CEN-CEIE_PLAN_REVIEW_CHECKLIST.docx DOCX document
BASE_FACILITY_DESIGN_STANDARD.docx DOCX document
APPENDIX_C_MASTER_ON_or_OFF_BASE_UPDATED_March_2015.docx DOCX document
Show all 50

Bldg. 503 Repair/Minor Const/Equipment has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Report

DEPARTMENT OF THE AIR FORCE
75TH CIVIL ENGINEERING (CEOHA)
HILL AIR FORCE BASE, UTAH
REQUESTER:Chris RowinsDATE:13-September-2016
ORGANIZATION:309 CMXG/EN
FROM:75TH CES/CEOHA
SUBJECT:Lead Based Paint (LBP) Survey,Building503
WORK ORDER:53153
SCOPE OF WORK:Repair/Modifications to the exterior.

Inspection Date: 24-August-2016 Inspector: Traver Andreasen (Utah Certified Lead Inspector #PB-2085)

Niton used for this inspection: XRF Analyzer XL2 600 (Serial #56999)

Building503
Built in:1995
Limited lead-based paint identification has been completed for,Building503

1-The table below summarizes the building components in building Building # that tested positive for LBP. These components should be segregated or abated prior to renovation or demolition, and a composite TCLP taken of the waste before disposal. (See attached results for further detail).

ComponentColorLead ReadingCondition
Metal BollardBrown8.6Good

2-The U.S. Department of Housing and Urban Development defines Lead-based paint as any paint, varnish, stain, or other applied coating that has 1mg/cm² as measured by an X-ray Fluorescence (XRF) Analyzer or laboratory analysis or 0.5 percent by weight (5,000µg/g by dry weight) by laboratory analysis, or more of lead. All other components tested were less than 0.80 mg/cm².

3-Any effort to disturb lead paint can create lead dust. Please ensure that appropriate abatement, cleanup, and disposal will be accomplished and that the appropriate safety measures are taken IAW 29 CFR 1926.62. If you have any questions please feel free to call Traver Andreasen at 777-8006.

Inspector: Traver Andreasen (Utah Certified Lead Inspector #PB-2085)

Niton:XRF Analyzer XL2 600 (Serial #56999)
Note:
Refer to "Readings" tab for all readings.
In order to print the entire LBP report select: "File", "Print", then select "Entire Workbook", "OK".

Readings

Building:503Inspector & Certification #:Traver Andreasen (Utah Certified Lead Inspector #PB-2085)
Date:24-August-2016
Time:1600
Work Order:53153
Pre CalibrationPbL (mg/cm²)Calibration RangeModel#Serial #Post CalibrationPbL (mg/cm²)Calibration Range
XRF Analyzer XL2 600 (Serial #56999)
12651.10Per 20 Second Reading12980.97Per 20 Second Reading
12660.9812991.13
12671.0913001.12
Range:.8 to 1.2Range:.8 to 1.2
XL NumberRoomSideStructureConditionSubstrateColorPbL(mg/cm2)NEG/POS
1274Exterior 503HEastSidingGoodMetalTan0.01NEG
1275Exterior 503HEastRoll-up Door JambGoodMetalBrown0.01NEG
1276Exterior 503HNorthSwamp Cooler RackGoodMetalBrown0.01NEG
1277Exterior 503HNorthFasciaGoodMetalBrown0.01NEG
1278503AEastHandrailGoodMetalBrown0.01NEG
1279Southeast StairwellSouthHandrailGoodMetalGrey0.01NEG
1280Southeast StairwellCenterStringerGoodMetalGrey0.01NEG
1281Southeast StairwellCenterStairGoodMetalGrey0.01NEG
1282503 ExteriorEastSoffitPoorDrywallTan0.01NEG
1283503 ExteriorEastSoffitPoorDrywallTan0.01NEG
1284503 ExteriorEastWallFairStuccoTan0.01NEG
1285503 A Loading DockSoutheastHandrailGoodMetalTan0.01NEG
1286503 A Loading DockSoutheast2" Dock LineGoodAsphaltYellow0.27NEG
1287503 A Loading DockSoutheastBollardGoodMetalBrown8.60POS
1288Tank AreaSoutheastFenceGoodMetalBrown0.01NEG
1289Tank AreaSouthShedGoodMetalBrown0.01NEG
1290Tank AreaSouthBollardGoodMetalBrown0.01NEG
1291503 ANortheastHandrailGoodMetalTan0.01NEG
1292503Northeast2" Dock LineGoodAsphaltWhite0.01NEG
1293503NortheastFire LaneGoodConcreteRed0.01NEG
1294503WestHandrailGoodMetalTan0.01NEG
1295503WestCoulmnGoodMetalTan0.01NEG
1296503WestBollardGoodConcreteTan0.01NEG
1297503 ASoutheastFire HydrantGoodMetalBrown0.01NEG
Traver Andreasen (Utah Certified Lead Inspector #PB-2085)
Chase Johnson (Utah Certified Lead Inspector #PB-2125)
Nickolas King (Utah Certified Lead Inspector #PB-1244)
Raudel Arteaga (Utah Certified Lead Inspector #PB-)
XRF Analyzer XL3t 300 (Serial #30660)
XRF Analyzer XL2 600 (Serial #56999)
XRF Analyzer XL3t 300 (Serial #96588)

image1.png image2.emf

File details come from the government source that posted it. Updated .