09 90 00 Paints and Coatings.pdf

PDF 41 KB Posted

Attached to
Construct catwalk for HVAC at building 238 Federal contract opportunity
Solicitation number
FA8201-10-B-0002
Issued by
Department of the Air Force Materiel Command Ogden Air Logistics Complex

About this file

Specification for paints and coating

View the file

Other files for this federal contract opportunity

Other files attached to Construct catwalk for HVAC at building 238, newest first.
File Type Posted
Questions and answers.doc DOC document
Amendment 2.pdf PDF
Group A photos.pdf PDF
Group B photos.pdf PDF
Group D photos.pdf PDF
Document.pdf PDF
Group C photos.pdf PDF
Clarification of work requirements for.docx DOCX document
Solicitation.doc DOC document
B238K072115-10-MH301.pdf PDF
B238K072115-08-MD101.pdf PDF
23 00 00 - Air Supply Distribution Ventilation and Exhaust Systems.pdf PDF
01 14 00 time change-2am.pdf PDF
23 07 00 - Thermal Insulation for Mechanical Systems.pdf PDF
05 50 13 Misc Metal Fabrications.pdf PDF
B238K072115-11-MH501.pdf PDF
23 05 93 - Testing Adjusting and Balancing for HVAC Systems.pdf PDF
B238K072115-06-S502.pdf PDF
01 14 00 Work Restrictions.pdf PDF
B238K072115-03-S001.pdf PDF
B238K072115-07-S503.pdf PDF
23 64 26 - Chilled Chilled-Hot and Condenser Water Piping Systems.pdf PDF
B238K072115-02-G002.pdf PDF
23 03 00.00 20 - Basic Mechanical Materials and Methods.pdf PDF
01 00 00 General Requirements.pdf PDF
B238K072115-05-S501.pdf PDF
05 12 00 Structural Steel.pdf PDF
B238K072115-09-MH101.pdf PDF
B238K072115-04-S101.pdf PDF
05 05 23 Welding Structural.pdf PDF
05 51 33 Metal Ladders.pdf PDF
B238K072115-01-G001.pdf PDF
Show all 32

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

KRSM 072115 Catwalks to Overhead HVAC, Building 238 Hill AFB, Utah

PAINTS AND COATINGS 09 90 00.00 40 - 1

SECTION TABLE OF CONTENTS

DIVISION 09 - FINISHES

SECTION 09 90 00.00 40

PAINTING AND COATING

06/06

PART 1 GENERAL

1.1 SUBMITTALS

1.2 CONTRACTOR PERSONNEL QUALIFICATION

1.3 DELIVERY, HANDLING, AND STORAGE

PART 2 PRODUCTS

2.1 MANUFACTURER'S AND MATERIALS

PART 3 EXECUTION

3.1 GENERAL

3.2 PROTECTION OF FACILITIES

3.3 SURFACE PREPARATION

3.3.1 General Requirements

3.3.2 Ferrous Metal

3.3.3 Galvanized Steel

3.3.4 Aluminum

3.4 MIXING AND APPLICATION

3.4.1 General Procedures

3.4.2 Procedures

3.5 ACCEPTANCE PROVISIONS

3.5.1 Inspection

3.5.2 Correction

3.6 PROTECTION

3.7 PAINT SCHEDULE (EXTERIOR)

3.8 PAINT SCHEDULE (INTERIOR)

-- End of Section Table of Contents --

PAINTS AND COATINGS 09 90 00.00 40 - 2

PART 1 GENERAL

1.1 SUBMITTALS

Government approval is required for submittals with a "G" designation; submittals not having a "G" designation are for information only. Submit the following in accordance with Section 01 00 00 paragraph SUBMITTALS:

SD-03 Product Data Manufacturer's catalog data shall be submitted for the following items. Data shall include detailed analysis of each coating material required, with constituents measured as percentages of the total weight of coating.

Alkyd-Enamel Finish System for Ferrous Metal (Primer, Undercoat, Finish Coat) Alkyd-Enamel Finish System for Zinc Coated Metal (Primer, Undercoat, Finish Coat)

SD-04 Samples Manufacturer's Standard Color Charts shall be submitted in accordance with paragraph entitled, "Manufacturer's and Materials," of this section.

SD-07 Certificates

A Safety Plan shall be submitted in accordance with paragraph entitled, "General," of this section and be included in Safety Plan required by Section 01 14 00 Work Restrictions.

SD-08 Manufacturer's Instructions

Manufacturer's instructions shall be submitted for architectural coatings including details of thinning, mixing, handling, and application, in accordance with paragraph entitled, "General," of this section.

1.2 CONTRACTOR PERSONNEL QUALIFICATION. Personnel assigned to the work shall be certified by the Contractor to have had adequate previous experience in the successful application of paints and coatings similar to those specified.

1.3 DELIVERY, HANDLING, AND STORAGE. Materials shall be delivered in their original, unbroken containers bearing the manufacturer's name and product identification. Containers breached by rough handling shall be removed from the site, together with their contents. Paint materials, thinners, and cleaners shall be stored in tightly closed containers in a covered, well-ventilated area where they will not be exposed to excessive heat, sparks, flame, or direct sunlight.

Water-based materials shall be protected against freezing.

PART 2 PRODUCTS

2.1 MANUFACTURER'S AND MATERIALS. Manufacturer's Standard Color Charts shall be submitted showing manufacturer's recommended finish colors. Three color chips of each color and gloss scheduled shall also be submitted. The following are suggested paint manufacturers. Other paint manufacturers' products of equal quality will be considered when submitted and approved by the Contracting Officer.

1. Devoe & Raynolds Co. (Devoe).

2. Fuller-O'Brien Paints (Fuller).

3. Glidden Co. (The) (Glidden).

4. Benjamin Moore & Co. (Moore).

5. PPG Industries, Inc. (PPG).

6. Pratt & Lambert, Inc. (P & L).

7. Sherwin-Williams Co. (S-W).

PAINTS AND COATINGS 09 90 00.00 40 - 3

PART 3 EXECUTION

3.1 GENERAL. A Safety Plan shall be submitted for architectural coating systems in accordance with

OSHA regulations. Manufacturer's recommendations for surface preparation, thinning, mixing, handling, and application shall be considered a part of this specification.

3.2 PROTECTION OF FACILITIES. Contractor shall remove and reinstall or provide acceptable protection for hardware, accessories, lighting and electrical components, factory-finished materials, plumbing fixtures and fittings, and any other materials that may become splattered or damaged by the painting work.

3.3 SURFACE PREPARATION

3.3.1 General Requirements. Surfaces shall be clean, dry, and free from contaminants and foreign matter. Mildew and chalking shall be removed and the surface thoroughly sterilized. Chipped, peeling, or blistered paint shall be removed and the surface spot primed. Hard glossy surfaces shall be dulled and roughened to ensure proper adhesion.

3.3.2 Ferrous Metal. Surfaces shall be free from dirt, oil, grease, wax, and other contaminants.

Heavy rust and loose mill scale shall be removed by hand, power tool, or blast cleaning.

3.3.3 Galvanized Steel. Surfaces shall be cleaned of all contaminants using a solvent such as lacquer thinner or xylol. After cleaning, the surface shall be etched with a phosporic acid pre-treatment solution.

3.3.4 Aluminum. Surfaces shall be clean, dry, and free from oil and grease. Oxide film and corrosion shall be removed by hand or power tool cleaning.

3.4 MIXING AND APPLICATION

3.4.1 General Procedures. No exterior painting shall be allowed in rainy weather or when rain is imminent. No paints or coatings shall be applied when the temperature or humidity is outside the limits recommended by the manufacturer. Paints and coatings shall be applied by brush, roller, or airless spray. Each coat of material applied shall be free from runs, sags, bubbles, foreign contaminants, variations in color, gloss, and texture, dry overspray, brush and roller marks, holidays (missed areas), or other evidence of poor application.

Paints and coatings shall be thoroughly worked into corners and crevices. Newly painted surfaces shall be adequately protected from damage.

3.4.2 Procedures. Paint systems shall be applied in accordance with the manufacturer's instructions. Coatings shall be applied as follows: Material shall be thoroughly stirred to produce a uniform mixture. Material shall be thinned for workability and improved spray characteristics, but only according to the manufacturer's instructions. Each coat shall be applied uniformly at the minimum wet-film thickness specified by the manufacturer.

Special attention shall be given when coating sharp edges, corners, and crevices to ensure complete coverage. Finish coats shall show good hiding characteristics and uniform appearance.

3.5 ACCEPTANCE PROVISIONS

3.5.1 Inspection. Contractor shall provide qualified personnel for inspection of his work to ensure that the requirements of this section have been fulfilled.

3.5.2 Correction. Spot-painting to correct damaged surfaces will be allowed only when touchup area blends into the surrounding finish. Otherwise, the entire area shall be recoated. Touchup shall be accomplished using the same method of application as was used to apply the original material.

3.6 PROTECTION. "WET PAINT" signs shall be posted to indicate newly painted surfaces.

3.7 PAINT SCHEDULE (EXTERIOR)

PAINTS AND COATINGS 09 90 00.00 40 - 4

3.7.1 Ferrous Metal: Provide the following finish systems over exterior ferrous metal. Primer is not required on shop-primed items.

3.7.1.1 Semigloss, Acrylic-Enamel Finish: 2 finish coats over a rust-inhibitive primer.

a. Primer: Rust-inhibitive metal primer applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 1.3 mils (0.033 mm).

1) Devoe: 13101 Mirrolac Rust Penetrating Metal Primer.

2) Fuller: 621-04 Blox-Rust Alkyd Metal Primer.

3) Glidden: 5205 Glid-Guard Tank & Structural Primer, Red.

4) Moore: IronClad Retardo Rust-Inhibitive Paint #163.

5) PPG: 6-208 Speedhide Interior/Exterior Rust Inhibitive Steel Primer.

6) P & L: S/D 1009 Suprime "9" Interior/Exterior Alkyd Metal Primer.

b. First and Second Coats: Semigloss, exterior, acrylic-latex enamel applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 2.6 mils (0.066 mm).

1) Devoe: 17XX Wonder-Shield Semi-Gloss Exterior Acrylic Latex House and Trim Paint.

2) Fuller: 664-XX Weather King II Semi-Gloss House & Trim Paint.

3) Glidden: 6600 Series Spred Ultra Exterior Gloss Latex House & Trim

Paint.

4) Moore: MoorGlo Latex House & Trim Paint #096.

5) PPG: 78 Line Sun-Proof Semi-Gloss Acrylic Latex House and Trim Paint.

6) P & L: Z/F 3100 Series Aqua Royal Latex House & Trim Finish.

3.7.1.2 Full-Gloss, Alkyd-Enamel Finish: 2 finish coats over a rust-inhibitive primer.

a. Primer: Rust-inhibitive metal primer applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 1.3 mils (0.033 mm).

1) Devoe: 13101 Mirrolac Rust Penetrating Metal Primer.

2) Fuller: 621-04 Blox-Rust Alkyd Metal Primer.

3) Glidden: 5205 Glid-Guard Tank & Structural Primer, Red.

4) Moore: IronClad Retardo Rust-Inhibitive Paint #163.

5) PPG: 6-208 Speedhide Interior/Exterior Rust Inhibitive Steel Primer.

6) P & L: S 4551 Tech-Gard High Performance Rust-Inhibitor Primer.

7) S-W: Kem Kromik Metal Primer B50N2/B50W1.

b. First and Second Coats: Full-gloss, exterior, alkyd enamel applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 3.0 mils (0.076 mm).

1) Devoe: 70XX Mirrolac Interior/Exterior Alkyd-Urethane Gloss Enamel.

2) Fuller: 312-XX Heavy-Duty Industrial Maintenance Enamel.

3) Glidden: 4500 Series Glid-Guard Alkyd Industrial Enamel.

4) Moore: Impervo Enamel #133.

5) PPG: 6-282 Speedhide Interior/Exterior Gloss-Oil Enamel.

6) P & L: S 4500 Series Tech-Gard Maintenance Gloss Enamel.

7) S-W: Industrial Enamel B-54 Series.

PAINTS AND COATINGS 09 90 00.00 40 - 5

3.7.2 Zinc-Coated Metal: Provide the following finish systems over exterior zinc-coated (galvanized) metal surfaces:

3.7.2.1 Semigloss, Acrylic-Enamel Finish: 2 finish coats over a galvanized metal primer.

a. Primer: Galvanized metal primer applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 1.2 mils (0.031 mm).

1) Devoe: 8502/8520 Mirrolac-WB Interior/Exterior Waterborne Flat DTM Primer and Finish.

2) Fuller: 621-05 Blox-Rust Latex Metal Primer.

3) Glidden: 5205 Glid-Guard Tank & Structural Primer, Red.

4) Moore: IronClad Galvanized Metal Latex Primer #155.

5) PPG: 90-709 Pitt-Tech One Pack Interior/Exterior Primer/Finish DTM

Industrial Enamel.

6) P & L: Z/F 1003 Suprime "3" Interior/Exterior Latex Metal Primer.

b. First and Second Coats: Semigloss, exterior, acrylic-latex enamel applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 2.6 mils (0.066 mm).

1) Devoe: 17XX Wonder-Shield Semi-Gloss Exterior Acrylic Latex House and Trim Paint.

2) Fuller: 664-XX Weather King II Semi-Gloss House & Trim Paint.

3) Glidden: 6600 Series Spred Ultra Exterior Gloss Latex House & Trim

Paint.

4) Moore: MoorGlo Latex House & Trim Paint #096.

5) PPG: 78 Line Sun-Proof Semi-Gloss Acrylic Latex House and Trim Paint.

6) P & L: Z/F 3100 Series Aqua Royal Latex House & Trim Finish.

3.7.2.2 Full-Gloss, Alkyd-Enamel Finish: 2 finish coats over a galvanized metal primer.

a. Primer: Galvanized metal primer applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 1.2 mils (0.031 mm).

1) Devoe: 8502/8520 Mirrolac-WB Interior/Exterior Waterborne Flat DTM Primer and Finish.

2) Fuller: 621-05 Blox-Rust Latex Metal Primer.

3) Glidden: 5205 Glid-Guard Tank & Structural Primer, Red.

4) Moore: IronClad Galvanized Metal Latex Primer #155.

5) PPG: 90-709 Pitt-Tech One Pack Interior/Exterior Primer/Finish DTM

Industrial Enamel.

6) P & L: Z/F 1003 Suprime "3" Interior/Exterior Latex Metal Primer.

7) S-W: Galvite Paint B50W3.

b. First and Second Coats: Full-gloss, exterior, alkyd enamel applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 2.6 mils (0.066 mm).

PAINTS AND COATINGS 09 90 00.00 40 - 6

1) Devoe: 70XX Mirrolac Interior/Exterior Alkyd-Urethane Gloss Enamel.

2) Fuller: 312-XX EPA Compliant Heavy-Duty Enamel.

3) Glidden: 4500 Series Glid-Guard Alkyd Industrial Enamel.

4) Moore: Impervo Enamel #133.

5) PPG: 6-282 Speedhide Interior/Exterior Gloss-Oil Enamel.

6) P & L: S 4500 Series Tech-Gard Maintenance Gloss Enamel.

3.8 PAINT SCHEDULE (INTERIOR)

3.8.1 Ferrous Metal: Provide the following finish systems over ferrous metal:

3.8.1.1 Semigloss, Alkyd-Enamel Finish: One finish coat over an enamel undercoater and a primer.

c. Primer: Quick-drying, rust-inhibitive, alkyd-based or epoxy-metal primer, as recommended by the manufacturer for this substrate, applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 1.5 mils (0.038 mm).

1) Devoe: 13101 Mirrolac Rust Penetrating Metal Primer.

2) Fuller: 621-04 Blox-Rust Alkyd Metal Primer.

3) Glidden: 5207 Glid-Guard Tank & Structural Primer, White.

4) Moore: IronClad Retardo Rust-Inhibitive Paint #163.

5) PPG: 6-208 Speedhide Interior/Exterior Rust Inhibitive Steel Primer.

6) P & L: S 4551 Tech-Gard High Performance Rust Inhibitor Primer.

7) S-W: Kem Kromik Metal Primer B50N2/B50W1.

d. Undercoat: Alkyd, interior enamel undercoat or semigloss, interior, alkyd-enamel finish coat, as recommended by the manufacturer for this substrate, applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 1.2 mils (0.031 mm).

1) Devoe: 26XX Velour Interior Alkyd Semi-Gloss Enamel.

2) Fuller: 220-07 Interior Alkyd Enamel Undercoat.

3) Glidden: UH 8400 Ultra Traditional Alkyd Semi-Gloss Enamel.

4) Moore: Moore's Alkyd Enamel Underbody #217.

5) PPG: 6-6 Speedhide Interior Quick-Drying Enamel Undercoater.

6) P & L: S/D 1011 Suprime "11" Interior Alkyd Wood Primer.

7) S-W: ProMar 200 Interior Alkyd Semi-Gloss Enamel B34W200.

e. Finish Coat: Odorless, semigloss, alkyd, interior enamel applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 1.4 mils (0.036 mm).

1) Devoe: 26XX Velour Interior Alkyd Semi-Gloss Enamel.

2) Fuller: 110-XX Fullerglo Alkyd Semi-Gloss Enamel.

3) Glidden: UH 8400 Ultra Traditional Alkyd Semi-Gloss Enamel.

4) Moore: Satin Impervo #235.

5) PPG: 27 Line Wallhide Low Odor Interior Enamel Wall and Trim Semi-

Gloss Oil.

6) P & L: S/D 5700 Cellu-Tone Alkyd Satin Enamel.

7) S-W: Classic 99 Interior/Exterior Semi-Gloss Alkyd Enamel A-40 Series.

3.8.1.2 Full-Gloss, Alkyd-Enamel Finish: 2 finish coats over an enamel undercoater and a primer.

PAINTS AND COATINGS 09 90 00.00 40 - 7

a. Primer: Quick-drying, rust-inhibitive, alkyd-based or epoxy-metal primer, as recommended by the manufacturer for this substrate, applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 1.5 mils (0.038 mm).

1) Devoe: 13101 Mirrolac Rust Penetrating Metal Primer.

2) Fuller: 621-04 Blox-Rust Alkyd & Structural Metal Primer.

3) Glidden: 5207 Glid-Guard Tank & Structural Primer, White.

4) Moore: IronClad Retardo Rust-Inhibitive Paint #163.

5) PPG: 6-208 Speedhide Interior/Exterior Rust Inhibitive Steel Primer.

6) P & L: S 4551 Tech-Gard High Performance Rust Inhibitor Primer.

7) S-W: Kem Kromik Metal Primer B50N2/B50W1.

b. Undercoat: Alkyd, interior enamel undercoat or full-gloss, interior, alkyd-enamel finish coat, as recommended by the manufacturer for this substrate, applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 1.2 mils (0.031 mm).

1) Devoe: 70XX Mirrolac Interior/Exterior Alkyd-Urethane Gloss Enamel.

2) Fuller: 220-07 Interior Alkyd Enamel Undercoat.

3) Glidden: 4500 Series Glid-Guard Alkyd Industrial Enamel.

4) Moore: Moore's Alkyd Enamel Underbody #217.

5) PPG: 6-6 Speedhide Interior Quick-Drying Enamel Undercoater.

6) P & L: S/D 1001 Suprime "11" Interior Alkyd Wood Primer.

7) S-W: Industrial Enamel B-54 Series.

c. Finish Coat: Full-gloss, alkyd, interior enamel applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 1.2 mils (0.031 mm).

1) Devoe: 70XX Mirrolac Interior/Exterior Alkyd-Urethane Gloss Enamel.

2) Fuller: 312-XX EPA Compliant Heavy-Duty Enamel.

3) Glidden: 4500 Series Glid-Guard Alkyd Industrial Enamel.

4) Moore: Impervo Enamel #133.

5) PPG: 54 Line Pittsburgh Paints Gloss-Oil Interior/Exterior Enamels.

6) P & L: S/D 1100 Series Effecto Enamel.

7) S-W: Industrial Enamel B-54 Series.

3.8.2 Zinc-Coated Metal: Provide the following finish systems over zinc-coated metal:

3.8.2.1 Semigloss, Alkyd-Enamel Finish: One finish coat over an undercoat and a primer.

a. Primer: Galvanized metal primer applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 1.2 mils (0.031 mm).

1) Devoe: 13201 Mirrolac Galvanized Metal Primer.

2) Fuller: 621-05 Blox-Rust Latex Metal Primer.

3) Glidden: 5207 Glid-Guard Tank & Structural Primer, White.

4) Moore: IronClad Galvanized Metal Latex Primer #155.

5) PPG: 90-709 Pitt-Tech One Pack Interior/Exterior Primer/Finish DTM

Industrial Enamel.

6) P & L: Z/F 1003 Suprime "3" Interior/Exterior Latex Metal Primer.

7) S-W: Galvite Paint B50W3.

PAINTS AND COATINGS 09 90 00.00 40 - 8

b. Undercoat: Alkyd, interior enamel undercoat or semigloss, interior, alkyd-enamel finish coat, as recommended by the manufacturer for this substrate, applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 1.2 mils (0.031 mm).

1) Devoe: 26XX Velour Interior Alkyd Semi-Gloss Enamel.

2) Fuller: 220-07 Interior Alkyd Enamel Undercoat.

3) Glidden: UH 8400 Series Spred Ultra Traditional Alkyd Semi-Gloss

Enamel.

4) Moore: Moore's Alkyd Enamel Underbody #217.

5) PPG: 6-6 Speedhide Interior Quick-Drying Enamel Undercoater.

6) P & L: S/D 1011 Suprime "11" Interior Alkyd Wood Primer.

7) S-W: ProMar 200 Interior Alkyd Semi-Gloss Enamel B34W200.

c. Finish Coat: Odorless, semigloss, alkyd, interior enamel applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 1.4 mils (0.036 mm).

1) Devoe: 26XX Velour Interior Alkyd Semi-Gloss Enamel.

2) Fuller: 110-XX Fullerglo Alkyd Semi-Gloss Enamel.

3) Glidden: UH 8400 Ultra Traditional Alkyd Semi-Gloss Enamel.

4) Moore: Satin Impervo #235.

5) PPG: 27 Line Wallhide Low Odor Interior Enamel Wall and Trim Semi-

Gloss Oil.

6) P & L: S/D 5700 Cellu-Tone Alkyd Satin Enamel.

7) S-W: Classic 99 Interior Alkyd Semi-Gloss Enamel A-40 Series.

3.8.2.2 Full-Gloss, Alkyd-Enamel Finish: One finish coat over an enamel undercoater and a primer.

a. Primer: Galvanized metal primer applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 1.2 mils (0.031 mm).

1) Devoe: 13201 Mirrolac Galvanized Metal Primer.

2) Fuller: 621-05 Blox-Rust Latex Metal Primer.

3) Glidden: 5207 Glid-Guard Tank & Structural Primer, White.

4) Moore: IronClad Galvanized Metal Latex Primer #155.

5) PPG: 90-709 Pitt-Tech One Pack Interior/Exterior Primer/Finish DTM

Industrial Enamel.

6) P & L: Z/F 1003 Suprime "3" Interior/Exterior Latex Metal Primer.

7) S-W: Galvite Paint B50W3.

b. Undercoat: Alkyd, interior enamel undercoat or semigloss, interior, alkyd-enamel finish coat, as recommended by the manufacturer for this substrate, applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 1.2 mils (0.031 mm).

1) Devoe: 70XX Mirrolac Interior/Exterior Alkyd-Urethane Gloss Enamel.

2) Fuller: 220-07 Interior Alkyd Enamel Undercoat.

3) Glidden: 4500 Series Glid-Guard Alkyd Industrial Enamel.

4) Moore: Moore's Alkyd Enamel Underbody #217.

5) PPG: 6-6 Speedhide Interior Quick-Drying Enamel Undercoater.

6) P & L: S/D 1001 Suprime "11" Interior Alkyd Wood Primer.

PAINTS AND COATINGS 09 90 00.00 40 - 9

c. Finish Coat: Full-gloss, alkyd, interior enamel applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 1.2 mils (0.031 mm).

1) Devoe: 70XX Mirrolac Interior/Exterior Alkyd-Urethane Gloss Enamel.

2) Fuller: 312-XX EPA Compliant Heavy-Duty Enamel.

3) Glidden: 4500 Series Glid-Guard Alkyd Industrial Enamel.

4) Moore: Impervo Enamel #133.

5) PPG: 54 Line Pittsburgh Paints Gloss-Oil Interior/Exterior Enamel.

6) P & L: S/D 1100 Series Effecto Enamel.

-- End of Section --