Attachment_2e_Appendix_E_MACC_SBCross_Reference_Matrix 4 May 26.xlsx
XLSX spreadsheet 88 KB Posted
- Solicitation number
- FA8137-26-R-0040
About this file
This is a Small Business Cross Reference Matrix appendix that establishes evaluation criteria and point-scoring methodology for construction and design experience submitted by offerors responding to the Tinker Air Force Base 2026 Multiple Award Construction Contract (MACC) solicitation FA8137-26-R-0040. The matrix requires offerors to document relevant experience across four primary sections: relevant construction experience, design experience, professional certifications/licenses, and staffing capabilities. All submitted projects must have been awarded on or after May 1, 2021, and be at least 80 percent complete as of the solicitation date.
The construction experience evaluation includes four categories: Commercial, Industrial & Residential Building projects with multiple trades (up to 5 projects valued at $1M-$5M for 200 points each, or $5M-$10M for 300 points each); Construction for the Department of Defense (up to 4 projects under $1M for 300 points each); Multiple Construction projects executed in parallel over at least 6 months with multiple trades (2-4 projects for 200 points each); and Individual Trade projects over $1M in specific categories including AT/FP measures, fire protection, road/parking/pavement, utility systems, roofing, and airfield construction (100 points each). The design experience section requires documentation of Design-Build project experience over $1M (maximum 400 points) with detailed compliance verification of specifications, drawings, and calculations against Unified Facilities Criteria and International Code Council standards. The certification section awards 100 points for each of four professional credentials: Project Management Professional, LEED Professional, Safety Professional, and Quality Professional. The staffing section evaluates the offeror's workforce across seven categories—trade/construction workers, architects/engineers, contract program managers, quality control managers, site safety and health managers, design program managers, and superintendents—with point values ranging from 100 to 200 points depending on staffing levels.
View the file
Other files
Show all 49
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SB Cross Reference Matrix
| Air Force Sustainment Center PZIOC MACC |
| Solicitation No.: FA813726R0040 |
| Appendix E to Section L, Small Business Cross Reference Matrix |
| Element | Offeror to Fill per Column C, Appendix C | Deliverables | Work Sample Number | Reference | |
| Document Title, Document Date, Page, Paragraph, Table Number (if applicable), Block (if applicable) | Notes / Clarifications (Optional) |
Clarifying facts to further substantiate the claim, such as coordinates of remotes sites named in Reference Documents
| EXAMPLE | $ | |||||
| 300 | Contract, SOW | WS2 | Example Contract #2 DD Form 1155, 1 Feb 2021, Pg 1 (block 24); SOW Pg 3 (Para 1.5.1) | DD Form 1155s Block 24 shows effective date of work sample and contract value |
SOW shows nature of work
| Instruction to Offeror Paragraph | Section 1 – RELEVANT CONSTRUCTION EXPERIENCE | |
| Relevant Experience Projects: (The submitted projects must meet the conditions listed, cannot be awarded prior to 1 May 2021, and at least 80% complete as of solicitation date) | ||
| Category 1 | Commercial, Industrial & Residential Bldg. Multi Trade | |
| Paragraph 5.1.1.1.1 | Submit a Project for each threshold, up to 5 total multiple trade projects for each | 1-5 Projects |
| Prime Contractor $1M to $5M Multiple Trades: Note: each project submitted receives a point value of 200pts | ||
| Prime Contractor $5M - $10M Multiple Trades: Note: each project submitted receives a point value of 300pts. | ||
| Paragraph 5.1.1.1.2 | Identify the number of trades per definitions provided in referenced paragraph. | 0-10 Projects |
| Number of trades 5-10 Note: each project submitted receives a max point value of 200pts. | ||
| Number of trades >10 Note: each project submitted receives a max point value of 300pts. | ||
| Category 2 | Construction for the DoW | |
| Paragraph 5.1.1.2. | Submit a Project executed for the US Government for each threshold, up to 4 total projects for each | 0-4 Projects |
| Prime Contractor Under $1M: Note: each project submitted receives a max point value of 300pts. | ||
| Category 3 | Multiple Construction Multi Trade | |
| Paragraph 5.1.1.3. | Submit 2 to 4 Projects executed in parallel during a period of at least 6 months, with multiple trades as defined in referenced paragraph. | 2-4 Projects |
| Prime Contractor Multiple Projects parallel in execution: Note: each project submitted receives a max point value of 200pts. | ||
| Category 4 | Individual Trade (Individual trade shall be at least 60% of total project) | |
| Paragraph 4.6.1.6. | Submit a Project for each threshold, up to 2 total individual trade projects for each | 0-1 Projects |
| Prime Contractor Over $1M AT/FP MEASURES (e.g. SECURITY FENCE/BARRIERS, WINDOWS): Note: each project submitted receives a point value of 100pts. | ||
| Prime Contractor Over $1M FIRE PROTECTION/SUPPRESSION SYSTEMS: Note: each project submitted receives a max point value of 100pts. | ||
| Prime Contractor Over $1M ROAD/PARKING/PAVEMENT CONSTRUCTION: Note: each project submitted receives a point value of 100pts. | ||
| Prime Contractor Over $1M UTILITY SYSTEM CONSTRUCTION: Note: each project submitted receives a point value of 100pts. | ||
| Prime Contractor Over $1M ROOFING: Note: each project submitted receives a point value of 100pts. | ||
| Prime Contractor Over $1M AIRFIELD CONSTRUCTION: Note: each project submitted receives a point value of 100pts. | ||
| Instruction to Offeror Paragraph | Section 2 - DESIGN EXPERIENCE | |
| Relevant Design Projects: (The submitted projects must meet the conditions listed, cannot be awarded prior to 1 May 2021, and at least 80% complete as of solicitation date) | ||
| Category 5 | Experience as Prime on Design-Build Projects (KTR Designing then Building) | |
| Paragraph 5.1.2.1. | Submit a Project with Design Build effort | 0-1 Projects |
| Prime Contractor over $1M: Note: each project submitted receives a max point value of 400pts. | ||
| Paragraph 5.1.2.2. | For the Project above submit all design documents in compliance with Unified Facilities Criteria (UFC) and the corresponding International Code Council (ICC) model codes and/or standards (i.e. NFPA, ASTM, ASCE) | Yes or No |
| Specifications: Note: completeness and accuracy of documents and compliance with local code requirements receives a point value of 20pts. | ||
| Interior and exterior walls (vertical construction elements) | ||
| Ceilings (horizontal construction elements) | ||
| Roofs | ||
| Waste water, water, and gas systems | ||
| Fire-extinguishing systems | ||
| Heat-supply systems | ||
| HVAC systems | ||
| Electrical systems | ||
| Communications, security and information systems | ||
| Building automation and automation of engineering structures | ||
| Drawings: Note: completeness and accuracy of documents and compliance with local code requirements receives a point value of 40pts. | ||
| Interior and exterior walls (vertical construction elements) | ||
| Ceilings (horizontal construction elements) | ||
| Roofs | ||
| Waste water, water, and gas systems | ||
| Fire-extinguishing systems | ||
| Heat-supply systems | ||
| HVAC systems | ||
| Electrical systems | ||
| Communications, security and information systems | ||
| Building automation and automation of engineering structures | ||
| Calculations: Note: completeness and accuracy of documents and compliance with local code requirements receives a point value of 40pts. | ||
| Interior and exterior walls (vertical construction elements) | ||
| Ceilings (horizontal construction elements) | ||
| Roofs | ||
| Waste water, water, and gas systems | ||
| Fire-extinguishing systems | ||
| Heat-supply systems | ||
| HVAC systems | ||
| Electrical systems | ||
| Communications, security and information systems | ||
| Building automation and automation of engineering structures | ||
| Instruction to Offeror Paragraph | Section 3 - CERTIFICATION/LICENSES | |
| Category 6 | Does the Offeror have each or any of the following? Type the word Yes or No in Column C. | |
| Paragraph 5.1.3.1. | Project Management Professionals | |
| Only one Yes which = 100pts /No = 0pts. | ||
| Paragraph 5.1.3.2. | LEED Professionals | |
| Only one Yes which = 100pts /No = 0pts. | ||
| Paragraph 5.1.3.3. | Safety Professional | |
| Only one Yes which = 100pts /No = 0pts. | ||
| Paragraph 5.1.3.4. | Quality Professional | |
| Only one Yes which = 100pts /No = 0pts. | ||
| Instruction to Offeror Paragraph | Section 4 - STAFFING | |
| Category 7 | Does the Offeror have the following employees on their staff or have they previously employed these positons as of 1 May 2021? Type the word Yes or No in Column C. | |
| Paragraph 5.1.4.1 | Trade/Construction Workers | |
| 1-5 Workers: Note: Only one Yes which = 100pts max /No = 0pts. | ||
| >5 Workers: Note: Only one Yes, which = 200pts. Max/No = 0pts | ||
| Paragraph 5.1.4.2. | Architects/Engineers | |
| 1-3 A/E: Note: Only one Yes which = 100pts max /No = 0pts. | ||
| >3 A/E: Note: Only one Yes which = 200pts max /No = 0pts. | ||
| Paragraph 5.1.4.3. | Contract Program Manager | |
| 1: Note: Only one Yes which = 100pts/No = 0pts. | ||
| >1: Note: Only one Yes which = 200pts/No = 0pts. | ||
| Paragraph 5.1.4.4. | Quality Control Manager | |
| 1-2: Note: Only one Yes which = 100 pts/No = 0 pts | ||
| >2: Note: Only one Yes which = 200 pts/No = 0 pts | ||
| Paragraph 5.1.4.5.1. | Site Safety and Health Manager | |
| Level 1 | ||
| Only one Yes which = 200pts max /No = 0pts. | ||
| Level 2 | ||
| 1-2: Note: Only one Yes which = 100pts max /No = 0pts. | ||
| >2: Note: Only one Yes which = 200pts max /No = 0pts. | ||
| Level 3 | ||
| 1-3: Note: Only one Yes which = 100pts max /No = 0pts. | ||
| >3: Note: Only one Yes which = 200pts max /No = 0pts. | ||
| Paragraph 5.1.4.6. | Design Program Manager | |
| 1: Note: Only one Yes which = 100pts max /No = 0pts. | ||
| >1: Note: Only one Yes which = 200pts max /No = 0pts. | ||
| Paragraph 5.1.4.7. | Superintendents | |
| 1-2: Note: Only one Yes which = 100pts max /No = 0pts. | ||
| >2: Note: Only one Yes which = 200pts max /No = 0pts. |
File details come from the government source that posted it. Updated .