Basic Year
| ATTACHMENT 5 Schedule B Excel Spreadsheet | BASIC YEAR | ||||
| SubCLIN | DESCRIPTION | UNIT | MAX EST QTY | UNIT PRICE | EXTENDED PRICE |
| 0001AA | Mechanical Fasteners |
Field-Of-Roof Spacing
| FM 1-120 Windstorm Class | SF | 100000 |
| 0001AB | Mechanical Fasteners |
Perimeter Roof Spacing
| FM 1-120 Windstorm Class | SF | 100000 |
| 0001AC | Mechanical Fasteners |
Corner Roof Spacing
| FM 1-120 Windstorm Class | SF | 30000 |
| 0001AD | Additional Screw Length |
to penetrate sheathing
| and board insulation - Fastener | EA | 50000 | ||
| 0001AE | Vapor Barrier | SF | 10000 | |
| 0001AF | Hot Asphalt Flood Coat | |||
| 0.6 Pounds per SF Coverage | SF | 10000 | ||
| 0001AH | Coarse Mineral Aggregate |
Water-worn Gravel
| ASTM D1863 | TON | 100 |
| 0001AJ | MB Cap Sheet Membrane |
APP Formulation 160 Mil Thicknes Granular Surface Polyester Reinforced
| Torch Applied | SF | 10000 | ||
| 0001AK | Pitch Pan | SF | 100 | |
| 0001AM | Elastomeric Gutter Liner |
Item Cost includes:
| epoxy adhesive | LF | 500 | ||
| 0001AN | MB Base Flashing | SF | 10000 | |
| 0001AP | Walkway |
3' x 3' x 3/4" Thick
| Asphalt Impregnated | SF | 2000 |
| 0001AQ | Walkway |
3' x 6' x 1/2" Thick
| Asphalt Impregnated | SF | 2000 | ||
| 0001AR | Lead Boots | EA | 400 | |
| 0001AS | Underlayment |
(SF)
Item Cost includes
| Mopped | SF | 10000 |
| 0001AT | Underlayment |
(SF)
Item Cost includes
| Mechanical Fasteners | SF | 10000 |
| 0001AU | Rigid Insulation Board |
Polyisocyanurate Foam 1" Thick Item Cost includes
| Mopped | SF | 600000 |
| 0001AW | Rigid Insulation Board |
Perlite 1" Thick Item Cost includes
| Mopped | SF | 300000 |
| 0001AY | Tapered Rigid Insulation |
Polyisocyanurate Foam 2" Average Thickness Item Cost Includes:
Factory tapered profile and
| Mopped | SF | 300000 |
| 0001BK | Industrial Metal Roofing |
Prefinished Steel GALV 24 GA Base Metal
Berridge Manufacturing Corp.
"M" Panel System
UL 90 Approval Listing Item Cost includes:
Mechanical Fasteners Matching closures and trim Kynar 500 Factory Finish
| Standard Color 1 - 10000 SF | SF | 10000 |
| 0001BL | Industrial Metal Roofing |
Prefinished Steel GALV 24 GA Base Metal
Berridge Manufacturing Corp.
"M" Panel System
UL 90 Approval Listing Item Cost includes:
Mechanical Fasteners Matching closures and trim Kynar 500 Factory Finish
| Standard Color 10001 - 100000 SF | SF | 100000 |
| 0001BM | Spray Polyurethane Foam |
Roof System
FM 1-90 Windstorm Class
Jones-Blair Company Neogard Division "Permathane II FR" Item Cost includes: Minimum coating total system thickness of 30 dry mils average (minimum 16 dry mils anywhere on the roof) 2 inch minimum spray polyurethane foam insulation thickness, Reference Section 01011, 2.2A10 Polyurethane Foam Elastomeric Coating Flashing tape Primer
| Perimeter Seals 1 - 10000 SF | SF | 10000 |
| 0001BN | Spray Polyurethane Foam |
Neogard Division "Permathane II FR" Item Cost includes: Minimum coating total system thickness of 30 dry mils average (minimum 16 dry mils anywhere on the roof) 2 inch minimum spray polyurethane foam insulation thickness, Reference Section 01011, 2.2A10 Polyurethane Foam Elastomeric Coating Flashing tape Primer
| Perimeter Seals 10001 - 100000 SF | SF | 100000 | ||
| 0001BQ | Construct Fencing | |||
| Chain Link 6'-0" | LF | 500 | ||
| 0001BS | Construct Gates | |||
| Chain Link Swing Operation | LF | 5 | ||
| 0001BT | Warranty Sign | EA | 10 | |
| 0001BU | On-Call Warranty Service |
Item Cost includes:
24 Hour Response
| On Government Notice | EA | 50 |
| 0001BV | 10 Year |
Manufacturer Warranty
| for Spec 07311 1 SF - 10,000 SF JOB | EA | 1 |
| 0001BW | 10 Year |
Manufacturer Warranty
| for Spec 07311 10,000 SF - 100,000 SF JOB | EA | 1 |
| 0001BX | 20 Year |
Manufacturer Warranty
| for Spec 07311 1 SF - 10,000 SF JOB | EA | 1 |
| 0001BY | 20 Year |
Manufacturer Warranty
| for Spec 07311 10,000 SF - 100,000 SF JOB | EA | 1 |
| 0001BZ | 10 Year |
Manufacturer Warranty
| for Spec 07512 1 SF - 10,000 SF JOB | EA | 1 |
| 0001CA | 20 Year |
Manufacturer Warranty
| for Spec 07512 1 SF - 10,000 SF JOB | EA | 1 |
| 0001CB | 10 Year NDL Systems Warranty | |
| for Spec 07536 1 SF - 10,000 SF JOB | EA | 1 |
| 0001CC | 10 Year NDL Systems Warranty | |
| for Spec 07536 10,001 SF - 100,000 SF JOB | EA | 1 |
| 0001CD | 10 Year NDL Systems Warranty | |
| for Spec 07536 100,001 SF - 500,000 SF JOB | EA | 1 |
| 0001CE | 20 Year NDL Systems Warranty | |
| for Spec 07536 1 SF - 10,000 SF JOB | SF | 2 |
| 0001CF | 20 Year NDL Systems Warranty | |
| for Spec 07536 10,001 SF - 100,000 SF JOB | SF | 2 |
| 0001CG | 20 Year NDL Systems Warranty | |
| for Spec 07536 100,001 SF - 500,000 SF JOB | SF | 2 |
| 0001CH | 10 Year NDL Systems Warranty |
for Spec 07537
| 1 SF - 10,000 SF JOB | EA | 1 |
| 0001CJ | 10 Year NDL Systems Warranty |
for Spec 07537
| 10,001 SF - 100,000 SF JOB | EA | 1 |
| 0001CK | 10 Year NDL Systems Warranty |
for Spec 07537
| 100,001 SF - 500,000 SF JOB | EA | 1 |
| 0001CL | 20 Year NDL Systems Warranty |
for Spec 07537
| 1SF - 10,000 SF JOB | EA | 1 |
| 0001CM | 20 Year NDL Systems Warranty |
for Spec 07537
| 10,001 SF - 100,000 SF JOB | EA | 1 |
| 0001CN | 20 Year NDL Systems Warranty |
for Spec 07537
| 100,001 SF - 500,000 SF JOB | EA | 1 |
| 0001CP | 10 Year NDL Systems Warranty |
for Spec 07538
| 1 SF - 10,000 SF JOB | EA | 2 |
| 0001CQ | 10 Year NDL Systems Warranty |
for Spec 07538
| 10,001 SF - 100,000 SF JOB | EA | 2 |
| 0001CR | 10 Year NDL Systems Warranty |
for Spec 07538
| 100,001 SF - 500,000 SF JOB | EA | 2 |
| 0001CS | 20 Year NDL Systems Warranty |
for Spec 07538
| 1 SF - 10,000 SF JOB | EA | 1 |
| 0001CT | 20 Year NDL Systems Warranty |
for Spec 07538
| 10,001 SF - 100,000 SF JOB | EA | 1 |
| 0001CU | 20 Year NDL Systems Warranty |
for Spec 07538
| 100,001 SF - 500,000 SF JOB | EA | 1 |
| 0001DD | 10 Year |
Manufacturer Warranty for Spec 07611
| 1 SF - 10,000 SF JOB | EA | 1 |
| 0001DE | 10 Year |
Manufacturer Warranty for Spec 07611
| 10,001 SF - 100,000 SF JOB | EA | 1 |
| 0001DF | 10 Year |
Manufacturer Warranty for Spec 07611
| 100,001 SF - 500,000 SF JOB | EA | N/A |
| 0001DG | 20 Year |
Manufacturer Warranty for Spec 07611
| 1 SF - 10,000 SF JOB | EA | 1 |
| 0001DH | 20 Year |
Manufacturer Warranty for Spec 07611
| 10,001 SF - 100,000 SF JOB | EA | 1 |
| 0001DJ | 20 Year |
Manufacturer Warranty for Spec 07611
| 100,001 SF - 500,000 SF JOB | EA | N/A |
| 0001DK | 10 Year |
Manufacturer Warranty for Industrial Metal Roof System
| 1 SF - 10,000 SF JOB | EA | 1 |
| 0001DL | 10 Year |
Manufacturer Warranty for Industrial Metal Roof System
| 10,001 SF - 100,000 SF JOB | EA | 1 |
| 0001DM | 20 Year |
Manufacturer Warranty for Industrial Metal Roof System
| 1 SF - 10,000 SF JOB | EA | 1 |
| 0001DN | 20 Year |
Manufacturer Warranty for Industrial Metal Roof System
| 10,001 SF - 100,000 SF JOB | EA | 1 |
| 0001DP | 10 Year |
Manufacturer Warranty for Spray Polyurethane Roof System
| 1 SF - 10,000 SF JOB | EA | 1 |
| 0001DQ | 10 Year |
Manufacturer Warranty for Spray Polyurethane Roof System
| 10,001 SF - 100,000 SF JOB | EA | 1 |
| 0001DR | Enclosed Debris Chute |
Item Cost includes:
Chute assembly;
Chute supports;
| Size by Contractor. | LF | 200 |
| 0001DS | Remove Built Up Roof |
Item Cost includes:
| up to 5 plies felt-asphalt 1 - 10,000 SF | SF | 10,000 |
| 0001DT | Remove Built Up Roof |
Item Cost includes:
| up to 5 plies felt-asphalt 10,001 - 100,000 SF | SF | 100,000 |
| 0001DU | Remove Built Up Roof |
Item Cost includes:
| up to 5 plies felt-asphalt 100,001 - 500,000 SF | SF | 500,000 |
| 0001DV | Remove Existing Coping | |
| Sheet Metal up to 12 inches wide 1 - 1000 LF | LF | 1000 |
| 0001DW | Remove Existing Coping |
| Sheet Metal up to 12 inches wide 1001 - 4000 LF | LF | 4000 | ||
| 0001DX | Remove Existing Coping | |||
| Sheet Metal up to 12 inches wide 4001 - 10000 LF | LF | 5000 | ||
| 0001DY | Remove Ballast | |||
| Vacuum clean 1 - 10000 SF | SF | 10,000 | ||
| 0001DZ | Remove Ballast | |||
| 10001 - 100000 SF | SF | 100,000 | ||
| 0001EA | Remove Ballast | |||
| 100001 - 500000 SF | SF | 110,000 | ||
| 0001EB | Remove Insulation | |||
| Per Inch Thickness 1 - 10000 SF | SF | 10,000 | ||
| 0001EC | Remove Insulation | |||
| Per Inch Thickness 10001 - 100000 SF | SF | 100,000 | ||
| 0001ED | Remove Insulation | |||
| Per Inch Thickness 100001 - 500000 SF | SF | 200,000 | ||
| 0001EF | Remove Underlayment 1 - 10000 SF | SF | 10,000 | |
| 0001EG | Remove Underlayment 10001 - 100000 SF | SF | 50,000 | |
| 0001EH | Remove Underlayment 100001 - 500000 SF | SF | 110,000 | |
| 0001EJ | Remove Interior Drains | |||
| 2" thru 4" Pipe Diameter | EA | 36 | ||
| 0001EK | Remove Gutter and Downspouts | LF | 1,500 | |
| 0001EL | Remove Base Flashing | |||
| Asbestos Containing | SF | 1000 | ||
| 0001EM | Remove Base Flashing | |||
| Non-Asbestos Containing | SF | 10000 | ||
| 0001EN | Remove Modified Bitumen Roofing |
Item Cost includes:
Flashing Cants
| Blocking 1 - 10000 SF | SF | 10000 |
| 0001EP | Remove Modified Bitumen Roofing |
Item Cost includes:
Flashing Cants
| Blocking 10001 - 100000 SF | SF | 100000 |
| 0001EQ | Remove Shingle Roofing |
Item Cost includes:
Nails Felts Underlayment Ice Dam Protection Membrane Eave and Rake Trim
| Penetration Flashings 1 - 10000 SF | SF | 10000 |
| 0001ER | Remove Shingle Roofing |
Item Cost includes:
Nails Felts Underlayment Ice Dam Protection Membrane Eave and Rake Trim
| Penetration Flashings 10001 - 100000 SF | SF | 100000 |
| 0001ES | Remove Single Ply Membrane |
Cost Item includes:
All Flashing Cants
| Blocking 1 - 10000 SF | SF | 10000 |
| 0001ET | Remove Single Ply Membrane |
Cost Item includes:
All Flashing Cants
| Blocking 10001 - 100000 SF | SF | 20000 |
| 0001EU | Remove Single Ply Membrane |
Cost Item includes:
All Flashing Cants
| Blocking 100001 - 500000 SF | SF | 100000 |
| 0001EW | Remove Standing Seam Roofing |
Item Cost includes:
Fasteners Underlayment
| Flashings 1 - 10000 SF | SF | 10000 |
| 0001EX | Remove Standing Seam Roofing |
Item Cost includes:
Fasteners Underlayment
| Flashings 10001 - 100000 SF | SF | 100000 |
| 0001EY | Remove Corrugated Metal Roofing |
Item Cost includes:
Fasteners Flashings Slip Sheet
| Eave and Rake Trim. 1 - 10000 SF | SF | 10000 |
| 0001EZ | Remove Corrugated Metal Roofing |
Item Cost includes:
Fasteners Flashings Slip Sheet
| Eave and Rake Trim. 10001 - 100000 SF | SF | 10001 |
| 0001FA | Replace Metal Decking |
to match existing
| 22 GA. Type "F" | SF | 10000 |
| 0001FB | Replace Wood Sheathing |
1 x 8 x 3/4" Southern Pine #2 Item Cost also includes:
| Nails. | SF | 1000 |
| 0001FC | Replace Wood Sheathing |
1 x 6 x 3/4" Southern Pine #2 Item Cost also includes:
| Nails. | SF | 1000 |
| 0001FD | Replace Wood Sheathing |
CDX Plywood 3/4" thick Item Cost also includes:
| Nails. | SF | 1000 |
| 0001FE | Replace Wood Sheathing |
CDX Plywood 5/8" thick Item Cost also includes:
| Nails. | SF | 1000 |
| 0001FF | Replace Wood Decking |
CDX Plywood 1/2" thick Item Cost also includes:
| Nails. | SF | 1000 |
| 0001FG | Replace Concrete Decking |
Lightweight Aggregate Insulating Fill over existing steel formdeck Item Cost also includes:
Average of 3" thickness;
| Substrate preparation. | SF | 1000 |
| 0001FH | Replace Structural Concrete Decking |
Item Cost also includes:
Average of 3" thickness;
Reinforcement Mesh;
| Steel Formdeck 22 GA. | SF | 5000 |
| 0001FJ | Remove and Reinstall Electric Ventilator/Fan Unit |
Item Cost includes:
Unit base dis-attachment.
Unit removal and protection.
Reconnection of electrical service.
Unit replacement on curb.
| Re-attachment of base to curb. Equipment Base Contact Area up to 4 SF | EA | 2 |
| 0001FK | Remove and Reinstall Electric Ventilator/Fan Unit |
Item Cost includes:
Unit base dis-attachment.
Unit removal and protection.
Reconnection of electrical service.
Unit replacement on curb.
| Re-attachment of base to curb. Equipment Base Contact Area exceeding 4 SF | EA | 2 |
| 0001FL | Remove and Reinstall |
Gravity-Powered Relief Damper Item Cost also includes:
Unit base dis-attachment.
Unit removal and protection.
Unit replacement on curb.
| Re-attachment of base to curb. | EA | 2 |
| 0001FM | Remove and Reinstall |
Rooftop HVAC Units Item Cost also includes:
Unit base dis-attachment.
Disconnect of electric.
Disconnect of all water piping.
Unit removal and protection.
Unit replacement on curb.
Re-connection of all piping.
Re-connection of electric.
Re-attachment of base to curb.
Re-balance of water supplies and returns.
| Re-testing of unit performance. 0 to 20 Tons Cooling Capacity | EA | 2 |
| 0001FN | Remove and Reinstall |
Rooftop HVAC Units Item Cost also includes:
Unit base dis-attachment.
Disconnect of electric.
Disconnect of all water piping.
Unit removal and protection.
Unit replacement on curb.
Re-connection of all piping.
Re-connection of electric.
Re-attachment of base to curb.
Re-balance of water supplies and returns.
| Re-testing of unit performance. 21 to 60 Tons Cooling Capacity | EA | 2 |
| 0001FP | Remove and Reinstall |
Rooftop HVAC Units Item Cost also includes:
Unit base dis-attachment.
Disconnect of electric.
Disconnect of all water piping.
Unit removal and protection.
Unit replacement on curb.
Re-connection of all piping.
Re-connection of electric.
Re-attachment of base to curb.
Re-balance of water supplies and returns.
| Re-testing of unit performance. Over 60 Tons Cooling Capacity | EA | 2 |
| 0001FQ | Remove and Reinstall |
Rooftop Hydronic HVAC Unit with Chilled Water Cooling and Electric Heat Coil
Item Cost also includes:
Unit base dis-attachment.
Disconnect of electric.
Disconnect of controls.
Disconnect water piping.
Unit removal and protection.
Unit replacement on curb.
Re-connection of all piping.
Re-connection of electric.
Re-connect of controls.
Re-attachment of base to curb.
Re-balance of water supply and return.
| Re-testing of unit performance. 0 to 20 Tons Cooling Capacity | EA | 2 |
| 0001FR | Remove and Reinstall |
Rooftop Hydronic HVAC Unit
Disconnect of electric.
Disconnect of controls.
Disconnect water piping.
Unit removal and protection.
Unit replacement on curb.
Re-connection of all piping.
Re-connection of electric.
Re-connect of controls.
Re-attachment of base to curb.
Re-balance of water supply and return.
| Re-testing of unit performance. 21 to 60 Tons Cooling Capacity | EA | 2 |
| 0001FS | Remove and Reinstall |
Rooftop Hydronic HVAC Unit
Disconnect of electric.
Disconnect of controls.
Disconnect water piping.
Unit removal and protection.
Unit replacement on curb.
Re-connection of all piping.
Re-connection of electric.
Re-connect of controls.
Re-attachment of base to curb.
Re-balance of water supply and return.
| Re-testing of unit performance. Over 60 Tons Cooling Capacity | EA | 2 |
| 0001FT | Remove and Reinstall |
Split DX A/C Unit Item Cost also includes:
All Work Required To Remove and Reinstall Split DX A/C Unit. (Rooftop AHU with Direct Expansion Refrigerant (DX0 Cooling Coil and Remote Condenser. Electrical Service, Control Wiring and Refrigerant Piping Connections Required.
| Include Refrigerant Recovery System. 0 to 20 Tons Cooling Capacity | EA | 2 |
| 0001FU | Remove and Reinstall |
Split DX A/C Unit Item Cost also includes:
All Work Required To Remove and Reinstall Split DX A/C Unit. (Rooftop AHU with Direct Expansion Refrigerant (DX0 Cooling Coil and Remote Condenser. Electrical Service, Control Wiring and Refrigerant Piping Connections Required.
| Include Refrigerant Recovery System. 21 to 60 Tons Cooling Capacity | EA | 2 |
| 0001FV | Remove and Reinstall |
Split DX A/C Unit Item Cost also includes:
All Work Required To Remove and Reinstall Split DX A/C Unit. (Rooftop AHU with Direct Expansion Refrigerant (DX0 Cooling Coil and Remote Condenser. Electrical Service, Control Wiring and Refrigerant Piping Connections Required.
| Include Refrigerant Recovery System. Over 60 Tons Cooling Capacity | EA | 2 |
| 0001FW | Remove and Reinstall |
DX HVAC Unit with DX Cooling Coil Electric Heat Coil and Remote Condenser Unit Item Cost also includes:
Unit base dis-attachment.
Disconnect of electric.
Disconnect of controls.
Disconnect refrigerant piping.
HVAC Unit removal and protection.
Condenser Unit removal and protection.
HVAC/Condenser Units' replacement.
Re-connection of refrigerant piping.
Re-connection of electric.
Re-connect of controls.
Re-attachment of base to curb.
Re-balance of air supply and return.
Re-testing of unit performance.
| Refrigerant Recovery System. 0 to 20 Tons Cooling Capacity | EA | 2 |
| 0001FX | Remove and Reinstall |
DX HVAC Unit with DX Cooling Coil Electric Heat Coil and Remote Condenser Unit Item Cost also includes:
Unit base dis-attachment.
Disconnect of electric.
Disconnect of controls.
Disconnect refrigerant piping.
HVAC Unit removal and protection.
Condenser Unit removal and protection.
HVAC/Condenser Units' replacement.
Re-connection of refrigerant piping.
Re-connection of electric.
Re-connect of controls.
Re-attachment of base to curb.
Re-balance of air supply and return.
Re-testing of unit performance.
| Refrigerant Recovery System. 21 to 60 Tons Cooling Capacity | EA | 2 |
| 0001FY | Remove and Reinstall |
DX HVAC Unit with DX Cooling Coil Electric Heat Coil and Remote Condenser Unit Item Cost also includes:
Unit base dis-attachment.
Disconnect of electric.
Disconnect of controls.
Disconnect refrigerant piping.
HVAC Unit removal and protection.
Condenser Unit removal and protection.
HVAC/Condenser Units' replacement.
Re-connection of refrigerant piping.
Re-connection of electric.
Re-connect of controls.
Re-attachment of base to curb.
Re-balance of air supply and return.
Re-testing of unit performance.
| Refrigerant Recovery System. Over 60 Tons Cooling Capacity | EA | 2 |
| 0001FZ | Remove and Reinstall |
Split System DX/Steam HVAC Unit with DX Cooling Coil Steam Heat Coil and Remote Condenser Unit Item Cost also includes:
Unit base dis-attachment.
Disconnect of electric.
Disconnect of controls.
Disconnect of refrigerant piping.
Disconnect of steam piping.
Disconnect of condensate piping.
HVAC /Condenser removal/protection.
HVAC/Condenser Units' replacement.
Re-connect of refrigerant piping.
Re-connect of electric.
Re-connect of steam piping.
Re-connect of condensate piping.
Re-connect of controls.
Re-attachment of base to curb.
Re-balance air supply and return.
Re-testing of unit performance.
| Refrigerant Recovery System. 0 to 20 Tons Cooling Capacity | EA | 2 |
| 0001GA | Remove and Reinstall |
Split System DX/Steam HVAC Unit with DX Cooling Coil Steam Heat Coil and Remote Condenser Unit Item Cost also includes:
Unit base dis-attachment.
Disconnect of electric.
Disconnect of controls.
Disconnect of refrigerant piping.
Disconnect of steam piping.
Disconnect of condensate piping.
HVAC /Condenser removal/protection.
HVAC/Condenser Units' replacement.
Re-connect of refrigerant piping.
Re-connect of electric.
Re-connect of steam piping.
Re-connect of condensate piping.
Re-connect of controls.
Re-attachment of base to curb.
Re-balance air supply and return.
Re-testing of unit performance.
| Refrigerant Recovery System. 21 to 60 Tons Cooling Capacity | EA | 2 |
| 0001GB | Remove and Reinstall |
Split System DX/Steam HVAC Unit with DX Cooling Coil Steam Heat Coil and Remote Condenser Unit Item Cost also includes:
Unit base dis-attachment.
Disconnect of electric.
Disconnect of controls.
Disconnect of refrigerant piping.
Disconnect of steam piping.
Disconnect of condensate piping.
HVAC /Condenser removal/protection.
HVAC/Condenser Units' replacement.
Re-connect of refrigerant piping.
Re-connect of electric.
Re-connect of steam piping.
Re-connect of condensate piping.
Re-connect of controls.
Re-attachment of base to curb.
Re-balance air supply and return.
Re-testing of unit performance.
| Refrigerant Recovery System. Over 60 Tons Cooling Capacity | EA | 2 | ||
| 0001GC | All Work Required To Remove and Reinstall Package A/C Unit. (Rooftop AHU With DX Coil With Built-In Condenser. Electrical Service and Control Wiring Connections Required.) 0 to 20 Tons Cooling Capacity | EA | 2 | |
| 0001GD | All Work Required To Remove and Reinstall Package A/C Unit. (Rooftop AHU With DX Coil With Built-In Condenser. Electrical Service and Control Wiring Connections Required.) 21 to 60 Tons Cooling Capacity | EA | 2 | |
| 0001GE | All Work Required To Remove and Reinstall Package A/C Unit. (Rooftop AHU With DX Coil With Built-In Condenser. Electrical Service and Control Wiring Connections Required.) Over 60 Tons Cooling Capacity | EA | 2 | |
| 0001GF | Remove and Reinstall |
Package HVAC Unit with DX Cooling Coil Electric Heat Coil Item Cost also includes:
Unit base dis-attachment.
Disconnect of electric.
Disconnect of controls.
Disconnect refrigerant piping.
HVAC Unit removal and protection.
HVAC Unit replacement.
Re-connection of refrigerant piping.
Re-connection of electric.
Re-connect of controls.
Re-attachment of base to curb.
Re-balance of air supply and return.
Re-testing of unit performance.
| Refrigerant Recovery System. 0 to 20 Tons Cooling Capacity | EA | 1 |
| 0001GG | Remove and Reinstall |
Package HVAC Unit with DX Cooling Coil Electric Heat Coil Item Cost also includes:
Unit base dis-attachment.
Disconnect of electric.
Disconnect of controls.
Disconnect refrigerant piping.
HVAC Unit removal and protection.
HVAC Unit replacement.
Re-connection of refrigerant piping.
Re-connection of electric.
Re-connect of controls.
Re-attachment of base to curb.
Re-balance of air supply and return.
Re-testing of unit performance.
| Refrigerant Recovery System. 21 to 60 Tons Cooling Capacity | EA | 1 |
| 0001GH | Remove and Reinstall |
Package HVAC Unit with DX Cooling Coil Electric Heat Coil Item Cost also includes:
Unit base dis-attachment.
Disconnect of electric.
Disconnect of controls.
Disconnect refrigerant piping.
HVAC Unit removal and protection.
HVAC Unit replacement.
Re-connection of refrigerant piping.
Re-connection of electric.
Re-connect of controls.
Re-attachment of base to curb.
Re-balance of air supply and return.
Re-testing of unit performance.
| Refrigerant Recovery System. Over 60 Tons Cooling Capacity | EA | 1 |
| 0001GJ | Remove and Reinstall |
Package HVAC Unit with DX Cooling Coil Steam Heat Coil Item Cost also includes:
Unit base dis-attachment.
Disconnect of electric.
Disconnect of controls.
Disconnect steam piping.
HVAC Unit removal and protection.
HVAC Unit replacement.
Re-connection of steam piping.
Re-connection of electric.
Re-connect of controls.
Re-attachment of base to curb.
Re-balance of air and water supply and return.
Re-testing of unit performance.
| Refrigerant Recovery System. 0 to 20 Tons Cooling Capacity | EA | 2 |
| 0001GK | Remove and Reinstall |
Package HVAC Unit with DX Cooling Coil Steam Heat Coil Item Cost also includes:
Unit base dis-attachment.
Disconnect of electric.
Disconnect of controls.
Disconnect steam piping.
HVAC Unit removal and protection.
HVAC Unit replacement.
Re-connection of steam piping.
Re-connection of electric.
Re-connect of controls.
Re-attachment of base to curb.
Re-balance of air and water supply and return.
Re-testing of unit performance.
| Refrigerant Recovery System. 21 to 60 Tons Cooling Capacity | EA | 2 |
| 0001GL | Remove and Reinstall |
Package HVAC Unit with DX Cooling Coil Steam Heat Coil Item Cost also includes:
Unit base dis-attachment.
Disconnect of electric.
Disconnect of controls.
Disconnect steam piping.
HVAC Unit removal and protection.
HVAC Unit replacement.
Re-connection of steam piping.
Re-connection of electric.
Re-connect of controls.
Re-attachment of base to curb.
Re-balance of air and water supply and return.
Re-testing of unit performance.
| Refrigerant Recovery System. Over 60 Tons Cooling Capacity | EA | 2 |
| 0001GM | Clear Interior Drain Piping |
Item Cost also includes:
Mechanical snake.
| Pipe Size up to 6" Diameter - LF/Drain | LF | 1500 |
| 0001GN | Clear Interior Drain Piping |
Item Cost also includes:
Mechanical snake.
| Pipe Size up to 12" Diameter - LF/Drain | LF | 200 | ||
| 0001GP | Cut Reglet | LF | 1000 | |
| 0001GQ | Fiber Cant 1-1/2" x 5-5/8" |
Trapezoidal Item Cost also includes:
| Attachment to Steel Deck | LF | 1000 |
| 0001GR | Lumber Cant 4" x 4" |
Southern Pine #2 Item Cost also includes:
Pressure Treated 4 x 4 Cut Diagonally
| Attachment to Steel Deck | LF | 2000 |
| 0001GS | Lumber Cant 4" x 4" |
Southern Pine #2 Item Cost also includes:
Diagonal Rip-cut Kiln Dried Untreated
| Attachment to Steel Deck | LF | 2000 |
| 0001GT | Lumber Blocking |
Southern Pine #2 Item Cost includes:
| Attachment to Steel Deck | BF | 1000 |
| 0001GU | 2" x 4" |
Southern Pine #2 Item Cost includes:
| Attachment to Steel Deck | LF | 1000 |
| 0001GV | 2" x 6" |
Southern Pine #2 Item Cost also includes:
| Attachment to Steel Deck | LF | 1000 |
| 0001GW | 2" x 8" |
Southern Pine # 2 Including:
| Attach to existing steel deck | LF | 1000 |
| 0001GX | 2" x 10" | |
| Attach to Steel Deck | LF | 1000 |
| 0001GY | Area Divider Curb | |
| NRCA Detail "BUR-9" p.207 | LF | 1000 |
| 0001GZ | Expansion Joint Assembly | |
| NRCA Detail "BUR-8" p.199 | LF | 1000 |
| 0001HA | Asphalt Heavy Weight |
Laminated Shingles Item Cost also includes:
Nails Pneumatic attachment Shingle Underlayment Plastic Cement Roofing Cement
| See Specification 07311 for more information. 1 - 10000 SF | SF | 10000 |
| 0001HB | Asphalt Heavy Weight |
Laminated Shingles Item Cost also includes:
Nails Pneumatic attachment Shingle Underlayment Plastic Cement Roofing Cement
| See Specification 07311 for more information. 10001 - 100000 SF | SF | 20000 |
| 0001HC | Asphalt Standard Weight Laminated Shingles |
Item Cost also includes:
Nails Pneumatic attachment 1 Ply #30 Felt Underlayment Plastic Cement Roofing Cement
| See Specification 07311 for more information. 1 - 10000 SF | SF | 10000 |
| 0001HD | Asphalt Standard Weight Laminated Shingles |
Item Cost also includes:
Nails Pneumatic attachment 1 Ply #30 Felt Underlayment Plastic Cement Roofing Cement
| See Specification 07311 for more information. 10001 - 100000 SF | SF | 20000 | ||
| 0001HE | Hip and Ridge Shingles | |||
| Asphalt Heavy Weight Laminated | LF | 200 | ||
| 0001HF | Hip and Ridge Shingles | |||
| Asphalt Standard Weight Laminated | LF | 200 | ||
| 0001HH | Ridge Vent | LF | 1000 | |
| 0001HJ | End Cap | EA | 40 | |
| 0001HK | Eave Protection | SF | 10000 | |
| 0001HL | Drip Edging | LF | 1400 | |
| 0001HM | Rake Trim | LF | 2000 | |
| 0001HN | Starter Strip | LF | 1000 | |
| 0001HP | Sheet Flashing |
Item Cost includes:
Nails Bituminous Paint
| Hemmed Exposed Edges | SF | 1000 |
| 0001HQ | 4 Ply BUR Coal Tar |
FM 1-120 Windstorm Class Item Cost also includes:
Cover Board Sheathing, Mechanical Attachments, Type II Felts, Bitumen, Primer and Cements, Base Flashings, Gravel Ballast and Flood Coat, Two Year Installer Warranty.
See Specifications 07512
| for additional requirements. 1 - 10000 SF | SF | 10000 |
| 0001HR | 4-Ply MB Hot |
FM 1-90 Listed System Item Cost also includes:
MB Cap Sheet, 3 Plies Type II Felts, Bitumen Type IV, Asphalt Primer and Cements, Cover Board Sheathing, Mechanical Attachments, Two Year Installer Warranty.
| See Spec 07536 for additional labor and materials required. 1 - 10000 SF | SF | 10000 |
| 0001HS | 4-Ply MB Hot |
FM 1-90 Listed System Item Cost also includes:
MB Cap Sheet, 3 Plies Type II Felts, Bitumen Type IV, Asphalt Primer and Cements, Cover Board Sheathing, Mechanical Attachments, Two Year Installer Warranty.
| See Spec 07536 for additional labor and materials required. 10001 - 100000 SF | SF | 100000 |
| 0001HT | 4-Ply MB Hot |
FM 1-90 Listed System Item Cost also includes:
MB Cap Sheet, 3 Plies Type II Felts, Bitumen Type IV, Asphalt Primer and Cements, Cover Board Sheathing, Mechanical Attachments, Two Year Installer Warranty.
| See Spec 07536 for additional labor and materials required. 100001 - 500000 SF | SF | 742500 |
| 0001HU | 2 Ply MB Hot |
FM 1-90 Windstorm Class Item Cost also includes:
Granular FG Reinforced MB Cap Sheet, MB Base Sheet, Bitumen, Asphalt Primer and Cements, Cover Board Sheathing, Mechanical Attachments, Two Year Installer Warranty.
Item excludes existing 20 GA steel deck.
| See Spec 07537 for additional labor and materials required. 1 - 10000 SF | SF | 10000 |
| 0001HV | 2 Ply MB Hot |
FM 1-90 Windstorm Class Item Cost also includes:
Granular FG Reinforced MB Cap Sheet, MB Base Sheet, Bitumen, Asphalt Primer and Cements, Cover Board Sheathing, Mechanical Attachments, Two Year Installer Warranty.
Item excludes existing 20 GA steel deck.
| See Spec 07537 for additional labor and materials required. 10001 - 100000 SF | SF | 100000 |
| 0001HW | 2 Ply MB Hot |
FM 1-90 Windstorm Class Item Cost also includes:
Granular FG Reinforced MB Cap Sheet, MB Base Sheet, Bitumen, Asphalt Primer and Cements, Cover Board Sheathing, Mechanical Attachments, Two Year Installer Warranty.
Item excludes existing 20 GA steel deck.
| See Spec 07537 for additional labor and materials required. 100001 - 500000 SF | SF | 500000 |
| 0001HX | 2 Ply MB Cold |
FM 1-90 Windstorm Class Item Cost also includes:
Granular FG Reinforced Cap Sheet, MB Base Sheet, Bitumen, Asphalt Primer and Cements, Cover Board Sheathing, Mechanical Attachments, Two Year Installer Warranty.
| See Spec 07538 for additional labor and materials required. 1 - 10000 SF | SF | 10000 |
| 0001HY | 2 Ply MB Cold |
FM 1-90 Windstorm Class Item Cost also includes:
Granular FG Reinforced Cap Sheet, MB Base Sheet, Bitumen, Asphalt Primer and Cements, Cover Board Sheathing, Mechanical Attachments, Two Year Installer Warranty.
| See Spec 07538 for additional labor and materials required. 10001 - 100000 SF | SF | 50000 |
| 0001HZ | 2 Ply MB Cold |
FM 1-90 Windstorm Class Item Cost also includes:
Granular FG Reinforced Cap Sheet, MB Base Sheet, Bitumen, Asphalt Primer and Cements, Cover Board Sheathing, Mechanical Attachments, Two Year Installer Warranty.
| See Spec 07538 for additional labor and materials required. 100001 - 500000 SF | SF | 300000 |
| 0001JA | Standing Seam Roof |
FM 1-120 Windstorm Class GALV 24 GA Base Metal Berridge Manufacturing Corp.
"Zee-Lock" Double Lock Panel Item Cost includes:
Seam weather seals #30 Felt Underlayment Bearing Plates Mechanical Fasteners Clips Metal panel joint sealants Matching closures and trim Kynar 500 Factory Finish Standard Color See Specifications 07611
| for additional requirements. 1 - 10000 SF | SF | 10000 |
| 0001JB | Standing Seam Roof |
FM 1-120 Windstorm Class GALV 24 GA Base Metal Berridge Manufacturing Corp.
"Zee-Lock" Double Lock Panel Item Cost includes:
Seam weather seals #30 Felt Underlayment Bearing Plates Mechanical Fasteners Clips Metal panel joint sealants Matching closures and trim Kynar 500 Factory Finish Standard Color See Specifications 07611
| for additional requirements. 10001 - 100000 SF | SF | 100000 |
| 0001JC | Standing Seam Roof |
FM 1-120 Windstorm Class GALV 24 GA Base Metal Berridge Manufacturing Corp.
"Zee-Lock" Double Lock Panel Item Cost includes:
Seam weather seals #30 Felt Underlayment Bearing Plates Mechanical Fasteners Clips Metal panel joint sealants Matching closures and trim Kynar 500 Factory Finish Standard Color See Specifications 07611
| for additional requirements. 100001 - 500000 SF | SF | N/A |
| 0001JD | Exposed Flashing |
Prefinished Steel Berridge Metal Corporation Item Cost includes:
Matching panel finish
| Matching panel thickness | LF | 5000 |
| 0001JE | Skirt Flashing |
Galvanized Steel, 24 GA NRCA Metal Roofing Manual Detail "F" Plate SM-15 Item Cost includes:
Hemmed Edges Fasteners
| Sealant | SF | 1000 |
| 0001JF | Reglet and Counterflashing |
24 GA Galvanized Steel NRCA Metal Roofing Manual Detail "C" Plate SM-14 Item Cost includes:
Receiver Counterflashing Flashing Clips Hemmed Edges Fasteners
| Sealant | SF | 2000 |
| 0001JG | Sheet Galvanized Steel | |
| 24 Gage | SF | 2000 |
| 0001JH | Sheet Stainless Steel | |
| 24 Gage | SF | 2000 |
| 0001JJ | Sheet Aluminum | |
| Mill Finish, 0.050" Thick | SF | 2000 |
| 0001JK | Downspout |
Galvanized Steel
| Factory Pre-Finished | LF | 1500 |
| 0001JL | Gutter |
Galvanized Steel Factory Pre-Finished Item Cost includes:
Brackets Attachments
| Joint Sealant | LF | 1000 |
| 0001JM | Vent Flashing Cap |
Galvanized Steel
24 GA.
for 3" Pipe Item Cost includes:
Drawband Sealant
| Neoprene Ring | EA | 200 |
| 0001JN | Through-Wall Scupper |
Galvanized Steel, 24 GA.
NRCA Detail BUR-24 page 256 Item Cost includes:
Sheet Metal Membrane Flashing Joint Soldering Sealant
| Wood Blocking | EA | 200 |
| 0001JP | Conductor Head |
Galvanized Steel, 24 GA Custom Shapes up to 12" x 24" x 12" Item Cost includes:
Sheet Metal Box Joint Soldering Overflow Outlet Downspout Outlet Hemmed Edges Scupper Cleat
| Sealant | EA | 200 |
| 0001JQ | Coping System |
Prefinished Steel
22 GA.
Petersen Aluminum Corp "PAC-Continuous Cleat Coping" Product Item Cost includes:
Coverage to 15" thickness Kynar 500 Factory Paint Standard Color FM 1-120 Windstorm Class See Specification Section 07620
| for additional requirements. | LF | 1000 |
| 0001JR | Utility Panel |
Prefinished Steel
24 GA
Petersen Aluminum Corp.
"M Panel" Product Item Cost includes:
Exposed Fasteners Kynar 500 Factory Paint Closure Strips 3 Stiffener Bead Flange See Specification 07620
| for additional requirements. | SF | 1000 |
| 0001JS | Gravel Stop |
Prefinished Steel
22 GA
Petersen Aluminum Corp.
"Type-F Gravel Stop" Product Item Cost includes:
Fasteners Kynar 500 Factory Paint Standard Color Continuous Cleat 6" Cover Plate Mitered Corners End Caps Splice Plates See Specification 07620
| for additional requirements. | LF | 200 |
| 0001JT | Soffit Panel |
Prefinished Steel
24 GA
Petersen Aluminum Corporation "Flush Panel" Item Cost includes:
Factory Finish Standard Color J Channel Trim See Specification 07620
| for additional requirements. | SF | 5000 |
| 0001JV | Channel Framing |
4" x 1 5/8" x 16 GA GALV Steel Berridge Manufacturing Company Structural Framing Item Cost includes:
GALV Finish Field-cuts
| Fasteners | LF | 2000 |
| 0001JW | Hat Section Purlin |
5 1/16" x 1 5/8" x 24 GA GALV Steel Berridge Manufacturing Company Structural Framing Item Cost includes:
GALV Finish Field-cuts
| Fasteners | LF | 2000 |
| 0001JX | Zee Purlin |
8" x 2 1/2" x 16 GA GALV Steel Berridge Manufacturing Company Structural Framing Item Cost includes:
Field-cuts
| Fasteners | LF | 500 |
| 0001JY | Gravel Stop |
Prefinished Steel
22 GA
Petersen Aluminum Corporation
"PAC-CLAD"
Type-F Item Cost includes:
Factory Finish Standard Color See Specification 07620
| for additional requirements. | SF | 2000 |
| 0001JZ | Running Trim |
Pre-Finished Steel
24 GA
Petersen Aluminum Corporation "PAC-CLAD" Flashing Custom Shapes Item Cost includes:
Fabrication Kynar 500 Factory Finish Standard Color
| Fasteners | LF | 1000 |
| 0001KA | Joint Cleaning |
and Preparation Item Cost includes:
Solvent Cleaning Full Depth, Masking Both Sides, Joint Primer,
| Moisture Removal | LF | 2000 |
| 0001KB | Backer Rod |
1/2" Polyethylene Tremco Product
| "Closed Cell Backer Rod" | LF | 2000 |
| 0001KC | One-Part Polyurethane |
1/4" x 1/4" In Place Tremco Product
| "Vulkem 116" | LF | 2000 |
| 0001KD | One-Part Polyurethane |
1/4" x 1/4" In Place Tremco Product
| "Vulkem 45 SSL" | LF | 2000 |
| 0001KE | One-Part Polyurethane |
1/4" x 1/4" in place Tremco "Dymeric 240/240 FC" Item Cost includes:
Backer Rod Sealant
| Tooling | LF | 2000 |
| 0001KF | Sealant Tape |
1/4" x 1" x LF 3M Product
| "Single Coat Foam Tape # 4314" | LF | 500 |
| 0001KG | Bond Breaker Tape |
Pressure-Sensitive Polyethylene Precision Paper Coatings Corporation
| Product "PPC # 650" | LF | 2000 |
| 0001KH | Cover Board |
Gypsum Panel 5/8" Thick Georgia Pacific Product "DensDeck Type X" Item Cost includes:
Screw attachment of panels to existing roofdeck
| Joint taping of panel edges | SF | 200000 |
| 0001KJ | Cover Board |
Gypsum Panel 1/4" Thick Georgia Pacific Corp.
"DensDeck" Item Cost includes:
Hot Asphalt Mopping
| Joint taping of panel edges | SF | 100000 | ||
| 0001KK | Tape Panel Joints | LF | 10000 | |
| 0001KL | Paint System 1 | LF | 1000 | |
| 0001KM | Paint System 2 | LF | 1000 | |
| 0001KN | Paint System 3 | LF | 1000 | |
| 0001KP | Paint System 4 | LF | 1000 | |
| 0001KQ | Paint System 5 | SF | 1000 | |
| 0001KR | Paint System 6 | SF | 1000 | |
| 0001KS | Paint System 7 | SF | 1000 | |
| 0001KT | Paint System 8 | SF | 1000 | |
| 0001KU | Paint System 9 | LF | 1000 | |
| 0001KV | Paint System 10 | LF | 1000 | |
| 0001KW | Paint System 11 | LF | 1000 | |
| 0001KX | Paint System 12 | LF | 1000 | |
| 0001KY | Interior Roof Drain |
CI
| 4" Pipe Diameter | EA | 25 |
| 0001KZ | Interior Roof Drain |
CI
| 6" Pipe Diameter | EA | 15 | ||
| 0001LA | Under-Deck Clamp for Above | EA | 40 | |
| 0001LB | Interior Drain Piping |
PVC
4" Pipe Diameter Couplings Spaced 10' OC
| Hanger Assemblies 3 per 10 Feet | LF | 1000 |
| 0001LC | Interior Drain Piping |
PVC
6" Pipe Diameter Couplings Spaced 10' OC
| Hanger Assemblies 3 per 10 Feet | LF | 1000 |
| 0001LD | Interior Drain Piping |
PVC
8" Pipe Diameter Couplings Spaced 10' OC
| Hanger Assemblies 3 per 10 Feet | LF | 1000 |
| 0001LE | 1/4 Bend | |
| 4" PVC Pipe | EA | 30 |
| 0001LF | 1/4 Bend | |
| 6" PVC Pipe | EA | 30 |
| 0001LG | 1/4 Bend | |
| 8" PVC Pipe | EA | 30 |
| 0001LH | Sanitary Tee | |
| 4" PVC Pipe | EA | 30 |
| 0001LJ | Sanitary Tee | |
| 6" PVC Pipe | EA | 30 |
| 0001LK | Sanitary Tee | |
| 8" PVC Pipe) | EA | 30 |
| 0001LL | Wye | |
| 4" PVC Pipe | EA | 30 |
| 0001LM | Wye | |
| 6" PVC Pipe | EA | 30 |
| 0001LN | Wye | |
| 8" PVC Pipe | EA | 30 |
| 0001LP | Reducer 4"x6" | |
| PVC | EA | 20 |
| 0001LQ | Reducer 6"x8" | |
| PVC | EA | 10 |
| 0001LR | Re-Install Fire Alarm |
Tranceiver Antenna
| Including Mounting | EA | 4 |
| 0001LS | Re-Test Fire Alarm Function |
Using Licensed Fire Alarm Subcontractor Following
| NFPA 72 Testing Form | EA | 4 | ||
| 0001LT | Re-Install Lightning Rod | EA | 60 | |
| 0001LU | Re-Install Conductor | EA | 60 | |
| 0001LV | New Lightning Rod | EA | 20 | |
| 0001LW | Test Fire Alarm Function | EA | 10 | |
| 0001LX | Rigid Insulation Board Polyisocyanurate Foam Field-of-Roof Spacing 1" Thick | |||
| Item Cost Includes: Mechanical Fasteners | SF | 100000 | ||
| 0001LY | Rigid Insulation Board Polyisocyanurate Foam Perimeter Roof Spacing 1" Thick | |||
| Item Cost Includes: Mechanical Fasteners | SF | 100000 | ||
| 0001LZ | Rigid Insulation Board Polyisocyanurate Foam Corner Roof Spacing 1" Thick | |||
| Item Cost Includes: Mechanical Fasteners | SF | 30000 | ||
| 0001MA | Rigid Insulation Board Perlite Field-of-Roof Spacing 1" Thick | |||
| Item Cost Includes: Mechanical Fasteners | SF | 100000 | ||
| 0001MB | Rigid Insulation Board Perlite Perimeter Roof Spacing 1" Thick | |||
| Item Cost Includes: Mechanical Fasteners | SF | 100000 | ||
| 0001MC | Rigid Insulation Board Perlite Corner Roof Spacing 1" Thick | |||
| Item Cost Includes: Mechanical Fasteners | SF | 30000 | ||
| 0001MD | Tapered Rigid Insulation Polyisocyanurate Foam Field-of-Roof Spacing 2" Average Thickness | |||
| Item Cost Includes: Factory tapered profile and Mechanical Fasteners | SF | 100000 | ||
| 0001ME | Tapered Rigid Insulation Polyisocyanurate Foam Perimeter Roof Spacing 2" Average Thickness | |||
| Item Cost Includes: Factory tapered profile and Mechanical Fasteners | SF | 100000 | ||
| 0001MF | Tapered Rigid Insulation Polyisocyanurate Foam Corner Roof Spacing 2" Average Thickness | |||
| Item Cost Includes: Factory tapered profile and Mechanical Fasteners | SF | 100000 | ||
| 0001MG | Test Roof Drains | |||
| Method 1 in accordance with Section 01410, 2.1.D | EA | 12 | ||
| 0001MH | Test Roof Drains | |||
| Method 2 in accordance with Section 01410, 2.1.E | EA | 12 | ||
| 0001MJ | Clean Roof Drains | |||
| In accordance with Section 01410 | EA | 300 | ||
| 0001MK | Industrial Metal Roofing |
Prefinished Steel GALV 24 GA Base Metal
Berridge Manufacturing Corp.
"R" Panel System
UL 90 Approval Listing Item Cost includes:
Mechanical Fasteners Matching closures and trim Kynar 500 Factory Finish
| Standard Color 1 - 10000 SF | SF | 10000 |
| 0001ML | Industrial Metal Roofing |
Prefinished Steel GALV 24 GA Base Metal
Berridge Manufacturing Corp.
"R" Panel System
UL 90 Approval Listing Item Cost includes:
Mechanical Fasteners Matching closures and trim Kynar 500 Factory Finish
| Standard Color 10001 - 100000 SF | SF | 100000 |
| 0001MM | Utility Panel |
Prefinished Steel
24 GA
Petersen Aluminum Corp.
"R Panel" Product Item Cost includes:
Exposed Fasteners Kynar 500 Factory Paint Closure Strips 3 Stiffener Bead Flange See Specification 07620 for additional requirements. SF 1000
Option I
| ATTACHMENT 5 Schedule B Excel Spreadsheet | OPTION YEAR I | ||||
| SubCLIN | DESCRIPTION | UNIT | MAX EST QTY | UNIT PRICE | EXTENDED PRICE |
| 1001AA | Mechanical Fasteners |
Field-Of-Roof Spacing
| FM 1-120 Windstorm Class | SF | 100000 |
| 1001AB | Mechanical Fasteners |
Perimeter Roof Spacing
| FM 1-120 Windstorm Class | SF | 100000 |
| 1001AC | Mechanical Fasteners |
Corner Roof Spacing
| FM 1-120 Windstorm Class | SF | 30000 |
| 1001AD | Additional Screw Length |
to penetrate sheathing
| and board insulation - Fastener | EA | 50000 | ||
| 1001AE | Vapor Barrier | SF | 10000 | |
| 1001AF | Hot Asphalt Flood Coat | |||
| 0.6 Pounds per SF Coverage | SF | 10000 | ||
| 1001AH | Coarse Mineral Aggregate |
Water-worn Gravel
| ASTM D1863 | TON | 100 |
| 1001AJ | MB Cap Sheet Membrane |
APP Formulation 160 Mil Thicknes Granular Surface Polyester Reinforced
| Torch Applied | SF | 10000 | ||
| 1001AK | Pitch Pan | SF | 100 | |
| 1001AM | Elastomeric Gutter Liner |
Item Cost includes:
| epoxy adhesive | LF | 500 | ||
| 1001AN | MB Base Flashing | SF | 10000 | |
| 1001AP | Walkway |
3' x 3' x 3/4" Thick
| Asphalt Impregnated | SF | 2000 |
| 1001AQ | Walkway |
3' x 6' x 1/2" Thick
| Asphalt Impregnated | SF | 2000 | ||
| 1001AR | Lead Boots | EA | 400 | |
| 1001AS | Underlayment |
(SF)
Item Cost includes
| Mopped | SF | 10000 |
| 1001AT | Underlayment |
(SF)
Item Cost includes
| Mechanical Fasteners | SF | 10000 |
| 1001AU | Rigid Insulation Board |
Polyisocyanurate Foam 1" Thick Item Cost includes
| Mopped | SF | 600000 |
| 1001AW | Rigid Insulation Board |
Perlite 1" Thick Item Cost includes
| Mopped | SF | 300000 |
| 1001AY | Tapered Rigid Insulation |
Polyisocyanurate Foam 2" Average Thickness Item Cost Includes:
Factory tapered profile and
| Mopped | SF | 300000 |
| 1001BK | Industrial Metal Roofing |
Prefinished Steel GALV 24 GA Base Metal
Berridge Manufacturing Corp.
"M" Panel System
UL 90 Approval Listing Item Cost includes:
Mechanical Fasteners Matching closures and trim Kynar 500 Factory Finish
| Standard Color 1 - 10000 SF | SF | 10000 |
| 1001BL | Industrial Metal Roofing |
Prefinished Steel GALV 24 GA Base Metal
Berridge Manufacturing Corp.
"M" Panel System
UL 90 Approval Listing Item Cost includes:
Mechanical Fasteners Matching closures and trim Kynar 500 Factory Finish
| Standard Color 10001 - 100000 SF | SF | 100000 |
| 1001BM | Spray Polyurethane Foam |
Neogard Division "Permathane II FR" Item Cost includes: Minimum coating total system thickness of 30 dry mils average (minimum 16 dry mils anywhere on the roof) 2 inch minimum spray polyurethane foam insulation thickness, Reference Section 01011, 2.2A10 Polyurethane Foam Elastomeric Coating Flashing tape Primer
| Perimeter Seals 1 - 10000 SF | SF | 10000 |
| 1001BN | Spray Polyurethane Foam |
Neogard Division "Permathane II FR" Item Cost includes: Minimum coating total system thickness of 30 dry mils average (minimum 16 dry mils anywhere on the roof) 2 inch minimum spray polyurethane foam insulation thickness, Reference Section 01011, 2.2A10 Polyurethane Foam Elastomeric Coating Flashing tape Primer
| Perimeter Seals 10001 - 100000 SF | SF | 100000 | ||
| 1001BQ | Construct Fencing | |||
| Chain Link 6'-0" | LF | 500 | ||
| 1001BS | Construct Gates | |||
| Chain Link Swing Operation | LF | 5 | ||
| 1001BT | Warranty Sign | EA | 10 | |
| 1001BU | On-Call Warranty Service |
Item Cost includes:
24 Hour Response
| On Government Notice | EA | 50 |
| 1001BV | 10 Year |
Manufacturer Warranty
| for Spec 07311 1 SF - 10,000 SF JOB | EA | 1 |
| 1001BW | 10 Year |
Manufacturer Warranty
| for Spec 07311 10,000 SF - 100,000 SF JOB | EA | 1 |
| 1001BX | 20 Year |
Manufacturer Warranty
| for Spec 07311 1 SF - 10,000 SF JOB | EA | 1 |
| 1001BY | 20 Year |
Manufacturer Warranty
| for Spec 07311 10,000 SF - 100,000 SF JOB | EA | 1 |
| 1001BZ | 10 Year |
Manufacturer Warranty
| for Spec 07512 1 SF - 10,000 SF JOB | EA | N/A |
| 1001CA | 20 Year |
Manufacturer Warranty
| for Spec 07512 1 SF - 10,000 SF JOB | EA | N/A |
| 1001CB | 10 Year NDL Systems Warranty | |
| for Spec 07536 1 SF - 10,000 SF JOB | EA | 1 |
| 1001CC | 10 Year NDL Systems Warranty | |
| for Spec 07536 10,001 SF - 100,000 SF JOB | EA | 1 |
| 1001CD | 10 Year NDL Systems Warranty | |
| for Spec 07536 100,001 SF - 500,000 SF JOB | EA | 1 |
| 1001CE | 20 Year NDL Systems Warranty | |
| for Spec 07536 1 SF - 10,000 SF JOB | SF | 2 |
| 1001CF | 20 Year NDL Systems Warranty | |
| for Spec 07536 10,001 SF - 100,000 SF JOB | SF | 2 |
| 1001CG | 20 Year NDL Systems Warranty | |
| for Spec 07536 100,001 SF - 500,000 SF JOB | SF | 2 |
| 1001CH | 10 Year NDL Systems Warranty |
for Spec 07537
| 1 SF - 10,000 SF JOB | EA | 1 |
| 1001CJ | 10 Year NDL Systems Warranty |
for Spec 07537
| 10,001 SF - 100,000 SF JOB | EA | 1 |
| 1001CK | 10 Year NDL Systems Warranty |
for Spec 07537
| 100,001 SF - 500,000 SF JOB | EA | 1 |
| 1001CL | 20 Year NDL Systems Warranty |
for Spec 07537
| 1SF - 10,000 SF JOB | EA | 1 |
| 1001CM | 20 Year NDL Systems Warranty |
for Spec 07537
| 10,001 SF - 100,000 SF JOB | EA | 1 |
| 1001CN | 20 Year NDL Systems Warranty |
for Spec 07537
| 100,001 SF - 500,000 SF JOB | EA | 1 |
| 1001CP | 10 Year NDL Systems Warranty |
for Spec 07538
| 1 SF - 10,000 SF JOB | EA | 2 |
| 1001CQ | 10 Year NDL Systems Warranty |
for Spec 07538
| 10,001 SF - 100,000 SF JOB | EA | 2 |
| 1001CR | 10 Year NDL Systems Warranty |
for Spec 07538
| 100,001 SF - 500,000 SF JOB | EA | N/A |
| 1001CS | 20 Year NDL Systems Warranty |
for Spec 07538
| 1 SF - 10,000 SF JOB | EA | 1 |
| 1001CT | 20 Year NDL Systems Warranty |
for Spec 07538
| 10,001 SF - 100,000 SF JOB | EA | 1 |
| 1001CU | 20 Year NDL Systems Warranty |
for Spec 07538
| 100,001 SF - 500,000 SF JOB | EA | N/A |
| 1001DD | 10 Year |
Manufacturer Warranty for Spec 07611
| 1 SF - 10,000 SF JOB | EA | 1 |
| 1001DE | 10 Year |
Manufacturer Warranty for Spec 07611
| 10,001 SF - 100,000 SF JOB | EA | 1 |
| 1001DF | 10 Year |
Manufacturer Warranty for Spec 07611
| 100,001 SF - 500,000 SF JOB | EA | 1 |
| 1001DG | 20 Year |
Manufacturer Warranty for Spec 07611
| 1 SF - 10,000 SF JOB | EA | 1 |
| 1001DH | 20 Year |
Manufacturer Warranty for Spec 07611
| 10,001 SF - 100,000 SF JOB | EA | 1 |
| 1001DJ | 20 Year |
Manufacturer Warranty for Spec 07611
| 100,001 SF - 500,000 SF JOB | EA | 1 |
| 1001DK | 10 Year |
Manufacturer Warranty for Industrial Metal Roof System
| 1 SF - 10,000 SF JOB | EA | 1 |
| 1001DL | 10 Year |
Manufacturer Warranty for Industrial Metal Roof System
| 10,001 SF - 100,000 SF JOB | EA | 1 |
| 1001DM | 20 Year |
Manufacturer Warranty for Industrial Metal Roof System
| 1 SF - 10,000 SF JOB | EA | 1 |
| 1001DN | 20 Year |
Manufacturer Warranty for Industrial Metal Roof System
| 10,001 SF - 100,000 SF JOB | EA | 1 |
| 1001DP | 10 Year |
Manufacturer Warranty for Spray Polyurethane Roof System
| 1 SF - 10,000 SF JOB | EA | 1 |
| 1001DQ | 10 Year |
Manufacturer Warranty for Spray Polyurethane Roof System
| 10,001 SF - 100,000 SF JOB | EA | 1 |
| 1001DR | Enclosed Debris Chute |
Item Cost includes:
Chute assembly;
Chute supports;
| Size by Contractor. | LF | 200 |
| 1001DS | Remove Built Up Roof |
Item Cost includes:
| up to 5 plies felt-asphalt 1 - 10,000 SF | SF | 10,000 |
| 1001DT | Remove Built Up Roof |
Item Cost includes:
| up to 5 plies felt-asphalt 10,001 - 100,000 SF | SF | 100,000 |
| 1001DU | Remove Built Up Roof |
Item Cost includes:
| up to 5 plies felt-asphalt 100,001 - 500,000 SF | SF | 500,000 |
| 1001DV | Remove Existing Coping | |
| Sheet Metal up to 12 inches wide 1 - 1000 LF | LF | 1000 |
| 1001DW | Remove Existing Coping |
| Sheet Metal up to 12 inches wide 1001 - 4000 LF | LF | 4000 | ||
| 1001DX | Remove Existing Coping | |||
| Sheet Metal up to 12 inches wide 4001 - 10000 LF | LF | 5000 | ||
| 1001DY | Remove Ballast | |||
| Vacuum clean 1 - 10000 SF | SF | 10,000 | ||
| 1001DZ | Remove Ballast | |||
| 10001 - 100000 SF | SF | 100,000 | ||
| 1001EA | Remove Ballast | |||
| 100001 - 500000 SF | SF | 110,000 | ||
| 1001EB | Remove Insulation | |||
| Per Inch Thickness 1 - 10000 SF | SF | 10,000 | ||
| 1001EC | Remove Insulation | |||
| Per Inch Thickness 10001 - 100000 SF | SF | 100,000 | ||
| 1001ED | Remove Insulation | |||
| Per Inch Thickness 100001 - 500000 SF | SF | 200,000 | ||
| 1001EF | Remove Underlayment 1 - 10000 SF | SF | 10,000 | |
| 1001EG | Remove Underlayment 10001 - 100000 SF | SF | 50,000 | |
| 1001EH | Remove Underlayment 100001 - 500000 SF | SF | 110,000 | |
| 1001EJ | Remove Interior Drains | |||
| 2" thru 4" Pipe Diameter | EA | 36 | ||
| 1001EK | Remove Gutter and Downspouts | LF | 1,500 | |
| 1001EL | Remove Base Flashing | |||
| Asbestos Containing | SF | 1000 | ||
| 1001EM | Remove Base Flashing | |||
| Non-Asbestos Containing | SF | 10000 | ||
| 1001EN | Remove Modified Bitumen Roofing |
Item Cost includes:
Flashing Cants
| Blocking 1 - 10000 SF | SF | 10000 |
| 1001EP | Remove Modified Bitumen Roofing |
Item Cost includes:
Flashing Cants
| Blocking 10001 - 100000 SF | SF | 100000 |
| 1001EQ | Remove Shingle Roofing |
Item Cost includes:
Nails Felts Underlayment Ice Dam Protection Membrane Eave and Rake Trim
| Penetration Flashings 1 - 10000 SF | SF | 10000 |
| 1001ER | Remove Shingle Roofing |
Item Cost includes:
Nails Felts Underlayment Ice Dam Protection Membrane Eave and Rake Trim
| Penetration Flashings 10001 - 100000 SF | SF | 100000 |
| 1001ES | Remove Single Ply Membrane |
Cost Item includes:
All Flashing Cants
| Blocking 1 - 10000 SF | SF | 10000 |
| 1001ET | Remove Single Ply Membrane |
Cost Item includes:
All Flashing Cants
| Blocking 10001 - 100000 SF | SF | 20000 |
| 1001EU | Remove Single Ply Membrane |
Cost Item includes:
All Flashing Cants
| Blocking 100001 - 500000 SF | SF | 100000 |
| 1001EW | Remove Standing Seam Roofing |
Item Cost includes:
Fasteners Underlayment
| Flashings 1 - 10000 SF | SF | 10000 |
| 1001EX | Remove Standing Seam Roofing |
Item Cost includes:
Fasteners Underlayment
| Flashings 10001 - 100000 SF | SF | 100000 |
| 1001EY | Remove Corrugated Metal Roofing |
Item Cost includes:
Fasteners Flashings Slip Sheet
| Eave and Rake Trim. 1 - 10000 SF | SF | 10000 |
| 1001EZ | Remove Corrugated Metal Roofing |
Item Cost includes:
Fasteners Flashings Slip Sheet
| Eave and Rake Trim. 10001 - 100000 SF | SF | 10001 |
| 1001FA | Replace Metal Decking |
to match existing
| 22 GA. Type "F" | SF | 10000 |
| 1001FB | Replace Wood Sheathing |
1 x 8 x 3/4" Southern Pine #2 Item Cost also includes:
| Nails. | SF | 1000 |
| 1001FC | Replace Wood Sheathing |
1 x 6 x 3/4" Southern Pine #2 Item Cost also includes:
| Nails. | SF | 1000 |
| 1001FD | Replace Wood Sheathing |
CDX Plywood 3/4" thick Item Cost also includes:
| Nails. | SF | 1000 |
| 1001FE | Replace Wood Sheathing |
CDX Plywood 5/8" thick Item Cost also includes:
| Nails. | SF | 1000 |
| 1001FF | Replace Wood Decking |
CDX Plywood 1/2" thick Item Cost also includes:
| Nails. | SF | 1000 |
| 1001FG | Replace Concrete Decking |
Lightweight Aggregate Insulating Fill over existing steel formdeck Item Cost also includes:
Average of 3" thickness;
| Substrate preparation. | SF | 1000 |
| 1001FH | Replace Structural Concrete Decking |
Item Cost also includes:
Average of 3" thickness;
Reinforcement Mesh;
| Steel Formdeck 22 GA. | SF | 5000 |
| 1001FJ | Remove and Reinstall Electric Ventilator/Fan Unit |
Item Cost includes:
Unit base dis-attachment.
Unit removal and protection.
Reconnection of electrical service.
Unit replacement on curb.
| Re-attachment of base to curb. Equipment Base Contact Area up to 4 SF | EA | 2 |
| 1001FK | Remove and Reinstall Electric Ventilator/Fan Unit |
Item Cost includes:
Unit base dis-attachment.
Unit removal and protection.
Reconnection of electrical service.
Unit replacement on curb.
| Re-attachment of base to curb. Equipment Base Contact Area exceeding 4 SF | EA | 2 |
| 1001FL | Remove and Reinstall |
Gravity-Powered Relief Damper Item Cost also includes:
Unit base dis-attachment.
Unit removal and protection.
Unit replacement on curb.
| Re-attachment of base to curb. | EA | 2 |
| 1001FM | Remove and Reinstall |
Rooftop HVAC Units Item Cost also includes:
Unit base dis-attachment.
Disconnect of electric.
Disconnect of all water piping.
Unit removal and protection.
Unit replacement on curb.
Re-connection of all piping.
Re-connection of electric.
Re-attachment of base to curb.
Re-balance of water supplies and returns.
| Re-testing of unit performance. 0 to 20 Tons Cooling Capacity | EA | 2 |
| 1001FN | Remove and Reinstall |
Rooftop HVAC Units Item Cost also includes:
Unit base dis-attachment.
Disconnect of electric.
Disconnect of all water piping.
Unit removal and protection.
Unit replacement on curb.
Re-connection of all piping.
Re-connection of electric.
Re-attachment of base to curb.
Re-balance of water supplies and returns.
| Re-testing of unit performance. 21 to 60 Tons Cooling Capacity | EA | 2 |
| 1001FP | Remove and Reinstall |
Rooftop HVAC Units Item Cost also includes:
Unit base dis-attachment.
Disconnect of electric.
Disconnect of all water piping.
Unit removal and protection.
Unit replacement on curb.
Re-connection of all piping.
Re-connection of electric.
Re-attachment of base to curb.
Re-balance of water supplies and returns.
| Re-testing of unit performance. Over 60 Tons Cooling Capacity | EA | 2 |
| 1001FQ | Remove and Reinstall |
Rooftop Hydronic HVAC Unit
Disconnect of electric.
Disconnect of controls.
Disconnect water piping.
Unit removal and protection.
Unit replacement on curb.
Re-connection of all piping.
Re-connection of electric.
Re-connect of controls.
Re-attachment of base to curb.
Re-balance of water supply and return.
| Re-testing of unit performance. 0 to 20 Tons Cooling Capacity | EA | 2 |
| 1001FR | Remove and Reinstall |
Rooftop Hydronic HVAC Unit
Disconnect of electric.
Disconnect of controls.
Disconnect water piping.
Unit removal and protection.
Unit replacement on curb.
Re-connection of all piping.
Re-connection of electric.
Re-connect of controls.
Re-attachment of base to curb.
Re-balance of water supply and return.
| Re-testing of unit performance. 21 to 60 Tons Cooling Capacity | EA | 2 |
| 1001FS | Remove and Reinstall |
Rooftop Hydronic HVAC Unit
Disconnect of electric.
Disconnect of controls.
Disconnect water piping.
Unit removal and protection.
Unit replacement on curb.
Re-connection of all piping.
Re-connection of electric.
Re-connect of controls.
Re-attachment of base to curb.
Re-balance of water supply and return.
| Re-testing of unit performance. Over 60 Tons Cooling Capacity | EA | 2 |
| 1001FT | Remove and Reinstall |
Split DX A/C Unit Item Cost also includes:
All Work Required To Remove and Reinstall Split DX A/C Unit. (Rooftop AHU with Direct Expansion Refrigerant (DX0 Cooling Coil and Remote Condenser. Electrical Service, Control Wiring and Refrigerant Piping Connections Required.
| Include Refrigerant Recovery System. 0 to 20 Tons Cooling Capacity | EA | 2 |
| 1001FU | Remove and Reinstall |
Split DX A/C Unit Item Cost also includes:
All Work Required To Remove and Reinstall Split DX A/C Unit. (Rooftop AHU with Direct Expansion Refrigerant (DX0 Cooling Coil and Remote Condenser. Electrical Service, Control Wiring and Refrigerant Piping Connections Required.
| Include Refrigerant Recovery System. 21 to 60 Tons Cooling Capacity | EA | 2 |
This is the start of the file's text. The full file is on GovTribe.
Other files for this federal contract opportunity
Show all 25
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
File details come from the government source that posted it. Updated .