This document contains questions and answers regarding Solicitation Number FA524023R0031 from the Department of the Air Force Pacific Air Forces to repair and install a command post radio and antenna system at Building 21007 on Andersen Air Force Base in Guam. Key details include that the contractor will be responsible for cable termination and routing conduits for communication equipment, with antennas to be mounted at the highest point of the side of the building and cabling to be run above ceiling tiles between Room 131 and Room 123. Combining multiple cables in a single conduit and using a minimum 1/2 inch conduit size are acceptable. Existing power outlets are available in Rooms 130 and 131.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Question # Reference Question/Comment Government Response
1 FA524023R0031 Request for Photos Refer to Section J, Attachment 8 in the solicitation
2 FA524023R0031 Requesting for As Built Drawings Refer to Section J, Attachment 9 in the solicitation
3 FA524023R0031
Please advise if conduit can be exposed and installed below ceiling. It can be but not desired.
4 FA524023R0031
Please adivice if galvanized conduit is to be used for this project?
Galvanized conduit does not have to be used.
5 FA524023R0031
Can we combine coax cable in single conduit? Or dedicated conduit per coax cable.
Yes, combining cables are acceptable.
6 FA524023R0031
What is the minimum sized of conduit allowed for each coax cable?
Most cables have a diameter of 1/2 inch minimum.
7 FA524023R0031
Do we need to provide power (receptacle outlet) for the new equipment?
Outlets are already existing in Rm 130 & 131.
8 FA524023R0031 Please advise if cable termination will be done by the contractor. Yes. This will be needed.
9 FA524023R0031
Please provide the exact location where to route conduits for the communication equipment.
Antennas need to be mounted to the side of the building at the highest point, with conduit going directly into Rm 131.
Route cabling/conduits anywhere above the ceiling tiles from Rm 131 (Radio Rm) to Rm 123 (EACell).
FA524023R0031 - REPAIR INSTALLATION COMMAND POST RADIO AND ANTENNA SYSTEM, BUILDING 21007 - Questions & Answers (Q & A)