Attachment 9 - AJJY 22-2008 As-Built.pdf
PDF 9 MB Posted
- Solicitation number
- FA524023R0031
About this file
This document package includes construction drawings and specifications for repair and installation work at Andersen Air Force Base in Guam. The project involves upgrading the command post radio and antenna system in Building 21007.
Key project details include repairing and replacing the roofing system with new concrete tiles or coatings; upgrading interior partitions and doors; installing a new raised flooring system; and replacing mechanical, electrical and plumbing systems. Foundation work includes repairing exterior load-bearing concrete walls, installing new footings, and pouring a new slab-on-grade. The drawings provide plans, elevations, sections and construction details, along with material specifications and schedules for concrete, masonry, metals and partition construction.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Repair Installation Command Post Radio and Antenna System, B21007 AJJY 22-2008
ANDERSEN AIR FORCE BASE, GUAM
CONCRETE:
No. 36 BARS AND SMALLER
No. 36 BARS AND SMALLER No. 43 AND No. 57 BARS
INTERIOR FRAMES
BEAMS AND COLUMNS - TIES, STIRRUPS, SPIRALS:
SLABS:
No. 43 AND No. 57 BARS
WALLS - INTERIOR FACE:
OTHER CONCRETE:
CONCRETE EXPOSED TO WEATHER:
CONCRETE CAST AGAINST AND PERMANENTLY
No. 16 BAR OR SMALLER No. 19 BAR OR LARGER
APPLICABLE CODES AND STANDARDS:
BUILDING CODE:
GENERAL:
REINFORCING STEEL:
ELECTRICAL CONDUIT:
SLEEVES:
CONSTRUCTION JOINTS:
ALL TYPICAL DETAILS AND NOTES SHOWN ON DRAWINGS SHALL
APPLY, UNLESS NOTED OTHERWISE. VERIFY AND COORDINATE WITH
VENDOR'S DRAWINGS FOR LOCATIONS OF ALL EMBEDS IN CONCRETE.
ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE BUILDING
CODE. THE PUBLICATIONS LISTED BELOW ARE THE GOVERNING CODES
AND STANDARDS AND ARE REFERENCED BY THE BASIC DESIGNATION.
IN THE CASE OF CONFLICTING REQUIREMENTS, THE BUILDING CODE
SHALL GOVERN.
MIXING AND PLACING OF ALL CONCRETE AND SELECTION OF MATERIALS
SHALL BE IN ACCORDANCE WITH THE BUILDING CODE. PROPORTIONS OF
AGGREGATE TO CEMENT SHALL BE SUCH AS TO PRODUCE A DENSE,
WORKABLE MIX WHICH CAN BE PLACED WITHOUT SEGREGATION OR
EXCESS FREE SURFACE WATER. ALL CONCRETE, INCLUDING SLABS ON
GROUND, SHALL HAVE AN ACCEPTABLE WATER-REDUCING ADMIXTURE
ADDED IN ACCORDANCE WITH MANUFACTURER'S DIRECTIONS. IN ADDITION,
ALL CONCRETE WALKS AND PAVEMENTS EXPOSED TO THE WEATHER
SHALL CONTAIN AN ACCEPTABLE ADMIXTURE TO PRODUCE 3 PERCENT
MINIMUM ENTRAINED AIR.
MAXIMUM SIZE OF AGGREGATE SHALL BE 19mm (3/4"), BUT MAXIMUM SIZE
OF AGGREGATE SHALL NOT BE MORE THAN THREE QUARTERS OF THE
CLEAR DISTANCE BETWEEN REINFORCING BARS. MAXIMUM SIZE OF
AGGREGATE FOR SLABS ON GROUND SHALL BE ONE THIRD OF SLAB
THICKNESS.
MIX DESIGNS SHALL BE SUBMITTED TO THE CONTRACTING OFFICER FOR
ACCEPTANCE PRIOR TO USE.
FORMWORK SHALL BE DESIGNED BY LICENSED PROFESSIONAL ENGINEER
(PE). CONTRACTOR SHALL SUBMIT DESIGN DRAWINGS AND CALCULATIONS
STAMPED AND SIGNED BY PE. FORMWORK SHALL BE SEALED TO PREVENT
GROUT FROM LEAKING DURING CASTING OF CONCRETE. FORMWORK
SHALL NOT BE STRIPPED LESS THAN 7 DAYS AFTER CASTING.
ALL CONSTRUCTION JOINTS IN WALLS SHALL BE KEYED IN ACCORDANCE
WITH THE TYPICAL CONSTRUCTION JOINT DETAILS SHOWN ON THE
STRUCTURAL DRAWINGS. IF NOT SPECIFICALLY INDICATED ON DRAWINGS,
ALL CONSTRUCTION JOINTS SHALL BE INTENTIONALLY ROUGHENED IN
ACCORDANCE WITH THE FOLLOWING: THE SURFACE OF ROUGHENED
CONSTRUCTION JOINTS SHALL BE HIGH-PRESSURE WATER-BLASTED OR
ROUGHENED WITH A CHIPPING HAMMER TO EXPOSE THE AGGREGATE
EMBEDDED IN THE PREVIOUS POUR. THE EXPOSED AGGREGATE SHALL
PROTRUDE A MINIMUM OF 6.35mm (1/4"). ALL SURFACES OF CONSTRUCTION
JOINTS SHALL BE CLEANED AND LAITANCES REMOVED. IMMEDIATELY
BEFORE NEW CONCRETE IS PLACED, ALL CONSTRUCTION JOINTS SHALL BE
WETTED AND STANDING WATER REMOVED. VERTICAL CONSTRUCTION
JOINTS IN WALLS SHALL BE HELD TO A MAXIMUM SPACING OF 18.3m (60').
THE CONTRACTOR SHALL SUBMIT THE PROPOSED LOCATIONS OF
CONSTRUCTION JOINTS TO THE CONTRACTING OFFICER FOR ACCEPTANCE
BEFORE STARTING CONSTRUCTION.
ALL REINFORCING STEEL SHALL BE CARRIED THRU CONSTRUCTION JOINTS.
EXCEPT AS DETAILED ON STRUCTURAL DRAWINGS, NO BEAMS OR GIRDERS
SHALL BE SLEEVED FOR PIPING OR DUCTS, UNLESS APPROVED BY THE
CONTRACTING OFFICER OR SLEEVE DIAMETER NOT EXCEEDING 51mm (2")
ANY PIPE PASSING THROUGH FOUNDATION OR WALL SHALL HAVE A PIPE
SLEEVE BUILT INTO THE FOUNDATION OR WALL. THE PIPE SLEEVE SHALL BE
TWO PIPE SIZES GREATER THAN THE PASSING PIPE. THE EXTERIOR WALLS
AND SLAB ON GRADE SHALL BE SEALED FOR WATER TIGHTNESS AROUND
THE PIPE PENETRATIONS. ALL PENETRATIONS SHALL BE TREATED FOR
FIRE-RESISTANCE RATING PER ARCHITECTURAL REQUIREMENTS. MIN
CLEARANCE BETWEEN SLEEVE PENETRATIONS IS 305 (12").
IF CONDUIT IS TO RUN IN SLABS, THE CONDUIT SHALL RUN AT MID-DEPTH
OF SLAB AND CONDUIT SIZE SHALL NOT EXCEED 33 PERCENT OF THE SLAB
DEPTH. THERE SHALL BE A MINIMUM OF 76mm (3") OF CLEAR SPACE BETWEEN CONDUITS. ALUMINUM CONDUIT IS PROHIBITED. PLACE No. 10 AT 305mm (12") ADDITIONAL REINFORCING ABOVE AND BELOW, PERPENDICULAR TO THE CONDUIT. THE ADDED REINF SHALL EXTEND
305mm (12") PAST THE CONDUITS ON BOTH SIDES.
REINFORCING STEEL SHALL BE NEW BILLET STOCK ASTM A 615/ A
615M, GRADE 420 MPa (60 KSI). REINFORCEMENT STEEL REQUIRED FOR WELDING SHALL BE ASTM A706 GRADE 420 MPa (60 KSI). BARS
SHALL BE SECURELY TIED IN PLACE WITH #16 DOUBLE-ANNEALED
IRON WIRE. BARS SHALL BE SUPPORTED ON ACCEPTABLE CHAIRS.
REINFORCING STEEL SHALL BE DETAILED IN ACCORDANCE WITH
THE ACI "MANUAL OF STANDARD PRACTICE FOR DETAILING OF
REINFORCED CONCRETE STRUCTURES." CONTRACTOR SHALL
COORDINATE REINFORCING STEEL PLACEMENT DETAILS AND
PROVIDE TEMPLATES FOR PLACING STEEL IN CONGESTED AREAS
AS NECESSARY. SHOP DRAWINGS (INCLUDING PLACEMENT PLANS
AND ELEVATIONS) SHALL BE SUBMITTED TO AND REVIEWED BY THE
CONTRACTING OFFICER BEFORE STARTING FABRICATION.
NO REINFORCING BARS SHALL BE WELDED, EXCEPT AS NOTED ON
THE DRAWINGS. WELDING OR TACK WELDING OF REINFORCING
BARS TO OTHER BARS OR TO PLATES, ANGLES, ETC. IS NOT
ALLOWED, EXCEPT WHERE SPECIFICALLY APPROVED BY THE
CONTRACTING OFFICER. WHERE WELDING IS APPROVED, IT SHALL
BE DONE BY AWS-CERTIFIED WELDERS USING E9018 OR
APPROVED ELECTRODES. WELDING PROCEDURES SHALL
CONFORM TO THE REQUIREMENTS OF AWS-D1.4.
MINIMUM CAST-IN-PLACE CONCRETE COVER OVER REINFORCING
STEEL, UNLESS OTHERWISE NOTED, SHALL BE AS FOLLOWS:
(IN CASE OF CONFLICTS, THE MORE STRINGENT CRITERIA SHALL
APPLY)
BUILDING CODE INTERNATIONAL BUILDING CODE 2015 (WITH
MODIFICATIONS IN UNIFIED FACILITIES CRITERIA
UFC 3-301-01)
ASCE 7-10 AMERICAN SOCIETY OF CIVIL ENGINEERS
"MINIMUM DESIGN LOADS FOR BUILDINGS AND
OTHER STRUCTURES"
ACI 530-08 / ASCE 5-08 BUILDING CODE REQUIREMENTS FOR MASONRY
STRUCTURES
ACI 318-11 AMERICAN CONCRETE INSTITUTE BUILDING
CODE REQUIREMENTS FOR STRUCTURAL
CONCRETE
ACI 315-99 DETAILS AND DETAILING OF CONCRETE
REINFORCEMENT
AISC STEEL CONSTRUCTION MANUAL, 13TH EDITION
AISC SPEC. FOR
STRUCTURAL JOINTS
AISC "SPECIFICATION FOR STRUCTURAL JOINTS
USING ASTM A325 & A490 BOLTS", JUNE 23, 2000
AWS D1.1 AMERICAN WELDING SOCIETY D1.1-2004,
"STRUCTURAL WELDING CODE - STEEL"
AWS D1.4 AMERICAN WELDING SOCIETY D1.4-98,
"STRUCTURAL WELDING CODE - REINFORCING
STEEL"
AWS A2.4 AMERICAN WELDING SOCIETY A2.4-2000,
"SYMBOLS FOR WELDING AND NONDESTRUCTIVE
TESTING"
AISI S100-07 AMERICAN IRON AND STEEL INSTITUTE, "NORTH
AMERICAN SPECIFICATION FOR THE DESIGN OF
COLD-FORMED STEEL STRUCTURAL MEMBERS"
(2007)
ASTM AMERICAN SOCIETY OF TESTING AND MATERIALS
ACI 305R GUIDE TO HOT WEATHER CONCRETING
ACI 207.1R-05 GUIDE TO MASS CONCRETE
UFC 1-200-01 GENERAL BUILDING REQUIREMENTS (2016)
UFC 3-301-01 STRUCTURAL ENGINEERING (2016)
UFC 3-310-04 SEISMIC DESIGN FOR BUILDINGS (2016)
UFC 3-340-01 DESIGN AND ANALYSIS OF HARDENED
STRUCTURES TO CONVENTIONAL WEAPONS
EFFECTS (2002)
UFC 3-340-02 STRUCTURES TO RESIST THE EFFECTS OF
ACCIDENTAL EXPLOSIONS (2008)
UFC 3-440-05N TROPICAL ENGINEERING (2006)
UFGS UNITED FACILITIES GUIDE SPECIFICATIONS
ANDERSEN AFB ARCHITECTURAL COMPATIBILITY
AND BASE DESIGN STANDARDS (2013)
LC
ABBREVIATIONS
EXPOSED TO EARTH
ALL CRACKS IN EXCESS OF .50 mm (0.02 in) WIDE SHALL BE DOCUMENTED
AND REPAIRED BY THE CONTRACTOR AT NO COST TO THE GOVERNMENT.
THE PROPOSED METHOD AND MATERIALS TO REPAIR THE CRACKS SHALL
BE SUBMITTED TO THE CONTRACTING OFFICER FOR APPROVAL.
THE SURFACE TOLERANCE FOR EXPOSED EXTERIOR CONCRETE IS CLASS
A. THE SURFACE TOLERANCE FOR THE SPALL PLATE IS CLASS B. ALL
OTHER SURFACES SHALL BE CLASS C. FOR THE STRUCTURE, THE
CONCRETE MUST BE PLACED AND VIBRATED AS SPECIFIED TO ENSURE NO
VOIDS OR HONEYCOMB OCCURS BETWEEN THE STEEL PLATE AND
CONCRETE SURFACE.
f'c W/C RATIO
MAXIMUM
SLUMP LOCATION
35 MPa (5 ksi)
0.40 203 (8") FOOTINGS, TOPPING, SLAB ON GRADE,
EXTERIOR ENCLOSURES & MECH YARD,
PIERS FOR SOLAR PANEL SUPPORT
FRAME
42 MPa (6 ksi)
0.35 203 (8") ALL LOAD-BEARING WALLS, ROOF
PARAPETS, ROOF SLAB, ROOF BEAMS,
ROOF TRUSSES, STRUCTURAL FINS,
ENTRY VESTIBULE WALLS, BLAST
CHASE, ENTRY WEATHER ENCLOSURE
WALL
28 MPa (4 ksi)
0.45 203 (8") CONCRETE PARTITION WALLS
GENERAL NOTES
A
ADD'L ADDITIONAL
ALT ALTERNATIVE
A.B. ANCHOR BOLT
ARCH ARCHITECTURAL
@ AT
B
BM BEAM
BOT BOTTOM
BRG BEARING
C
CIP CAST-IN-SITU
CENTER LINE
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONST CONSTRUCTION
C.J. CONSTRUCTION JOINT
CONT CONTINUOUS
D
DBL DOUBLE
DET DETAIL
DIA DIAMETER
DIM DIMENSION
DN DOWN
DWG DRAWING
E
EA EACH
E.F. EACH FACE
E.W. EACH WAY
ELEV ELEVATION
EMBD EMBEDDED
EQUIV EQUIVALENT
EQ EQUAL
EXIST'G EXISTING
F
FLG FLANGE
FLR FLOOR
FP FIRE PROTECTION
F.P. FULL PENETRATION
FTG FOOTING
FDN FOUNDATION
G
GALV GALVANIZED
H
HORIZ HORIZONTAL
H.S. HEADED STUD
HSB HIGH-STRENGTH BOLT
HSS HOLLOW STRUCTURAL
SECTION
HT HEIGHT
I
IP IMPERIAL
INFO INFORMATION
INT INTERIOR
L
L LENGTH
LG LONG
M
MFR MANUFACTURE
MAX MAXIMUM
MID MIDDLE
MIN MINIMUM
M/E MECHANICAL / ELECTRICAL
MECH MECHANICAL
N
No. NUMBER
NTS NOT TO SCALE
O
O.C. ON CENTER
OPEN'G OPENING
OPP OPPOSITE
P
PL PLATE
P.T. POST TENSIONED
PC PRECAST
PS PRESTRESSED
R
REINF REINFORCING
RF ROOF
S
SCHE SCHEDULE
SECT SECTION
SIM SIMILAR
SOG SLAB ON GRADE
SPECS SPECIFICATIONS
STD STANDARD
STIFF STIFFENER
STL STEEL
SYMM SYMMETRIC
T
THK THICK
THRU THROUGH
THRUOUT THROUGH OUT
T&B TOP AND BOTTOM
TOT TOTAL
TYP TYPICAL
TOC TOP OF CONCRETE
TOP'G TOPPING
U
U.N.O. UNLESS NOTED OTHERWISE
V
VAR VARIES
VERT VERTICAL
V&H VERTICAL AND HORIZONTAL
W
WT WEIGHT
W/ WITH
W/C WATER/CEMENTITIOUS
38mm (1 1/2")
38mm (1 1/2")
75mm (3")
50mm (2")
25mm (1")
25mm (1")
38mm (1 1/2")
38mm (1 1/2")
B-1 b
USA STEEL REINFORCEMENT BAR SIZES
METRIC BAR IP EQUIV
SIZE mm² in² SIZE
No. 10 70.97 0.11 #3 No. 13 129.0 0.20 #4 No. 16 200.0 0.31 #5 No. 19 283.9 0.44 #6 No. 22 387.1 0.60 #7 No. 25 509.7 0.79 #8 No. 29 645.2 1.00 #9 No. 32 819.4 1.27 #10 No. 36 1006.4 1.56 #11 No. 43 1451.6 2.25 #14 No. 57 2580.6 4.00 #18
MINIMUM REINF STEEL LAP SPLICE LENGTH SHALL BE 48d (d=DIAMETER OF REBAR) AND PER TABLE 4 ON SHEET S-501, UNLESS
NOTED ON DRAWING. LAP SPLICE SHALL BE STAGGERED WITH NO
MORE THAN 50% REBAR LAPPED WITHIN 1.524 METERS (5'-0").
MAXIMUM WATER-CEMENT RATIO AND SLUMP SHALL BE AS FOLLOWS FOR
VARIOUS CONCRETE STRENGTHS (f'c) BASED ON STANDARD
28-DAY CYLINDER TESTS. SLUMP INDICATED BELOW IS AFTER ADDING
SUPER PLASTICIZER. USE MINIMUM 15% (BY WEIGHT) FLY ASH
CONFORMING TO SPECS.
ALL ROOF SLABS, BEAMS, FOUNDATION SLABS WITH MIN DIMENSIONS
EXCEEDING 305mm (12") SHALL CONTAIN APPROVED RETARDING
ADMIXTURE TO MITIGATE FLASH SETTING AND THERMAL CRACKING.
STANDARD AGE OF CONCRETE CYLINDERS CONTAINING FLY ASH AND/ OR
CHEMICAL RETARDANT FOR COMPRESSIVE AND FLEXURAL STRENGTH
TESTING SHALL BE 56 DAYS.
LAP SPLICES ARE NOT ALLOWED FOR SUPERSTRUCTURES FOR
REBAR SIZES No. 25 (#8) OR LARGER. TYPE 2 MECHANICAL SPLICES
(CONFORMING TO ACI 318) MUST BE USED FOR THESE STRUCTURAL
MEMBERS. MECHANICAL SPLICES MAY BE LOCATED ANYWHERE AND
IN ANY GEOMETRIC ALIGNMENT WITHOUT CAUSING CONGESTIONS
AND HONEYCOMBS IN CASTING. ALL STIRRUPS AND TIES SHALL BE
CLOSED WITH 135 DEGREE SEISMIC HOOKS AS DETAILED ON S-004,
UNLESS NOTED ON DRAWINGS. ALL REBAR SHALL BE ENDED WITH
90° HOOKS UNLESS NOTED ON DRAWINGS. NO REBAR SHALL BE
TEMPORARILY BENT MORE THAN ONCE FROM FINAL POSITION.
SYMBOLS
EARTH
CMU
IN-SITU CONCRETE
PRECAST CONCRETE
STEEL
OPENING
ONE WAY SLAB
SPANNING
REBAR TAG
BEAM TAG
REBAR
LEVEL INDICATOR
SPOT ELEVATION
KEYNOTE SYMBOL
LESS THAN OR EQUAL
TO
CONCRETE PARTITION WALLS:
CONCRETE PARTITION WALLS AS INDICATED ON DRAWINGS ARE
CONSIDERED NON STRUCTURAL SYSTEM COMPONENTS. THESE WALLS
SHALL BE SEPARATED FROM LOAD-BEARING WALLS AND ROOF SLABS WITH
MINIMUM 3/4" GAP UNLESS NOTED ON DRAWINGS. THE GAP SHALL BE
TREATED FOR FIRE RATING ESTABLISHED BY ARCHITECT. CONTRACTOR
MAY PROPOSE PRECAST PARTITION WALLS FOR ENGINEER'S APPROVAL.
ALL REBAR, ANCHOR BOLTS AND EMBEDS SHALL BE CLEAN AND
FREE OF OIL, DIRT, DUST OR ANY SUBSTANCE WHICH MAY REDUCE
BOND WITH CONC. REBAR SHALL BE PLACED PROPERLY TO
PROVIDE SUFFICIENT COVER REQUIRED BY DESIGN AND AVOID
CONGESTIONS WHICH MAY CAUSE HONEYCOMBS.
S-001
G
EN
ER
AL
N O
TE
S, S
YM
BO
LS
A N
D A
BB
R
EV
IA
TI
O
N S
17195923
JACOBS/BURNS & MCDONNELL, A JOINT VENTURE
155 NORTH LAKE AVENUE
PASADENA, CA 91101 USA
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE
AP
R
IN
ST
AL
LA
TI
ON
C
ON
TR
OL
C
EN
TE
R
FY
M
CA
F
PR
OJ
EC
T P-
0/A
JJ
Y1
JR
M
- A
ND
ER
SE
N
AI
R
FO
RC
E
BA
SE
GU
AM
, M
AR
IA
NA
IS
LA
ND
S
NA
VF
AC
M
AR
IA
NA
S
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
JR
M-
AN
DE
RS
EN
A
IR
F
OR
CE
B
AS
E
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
M
AR
IA
N
AS
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
1 2 3 4 5
D
C
B
A
1 2 3 4 5
D
C
B
A
BZ ZKS AAY
SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON FULL SIZE ANSI D (22" x 34") SHEET.
AS SHOWN
JEG NO. FDWD7921
1342285
C
FIRE PROTECTION
FO
R
OF
FI
CI
AL
U
SE
O
NL
Y (F
OU
O)
N62742-10-D-0007
16 FEB 2017
MASONRY:
STRUCTURAL STEEL:
SHOP DRAWINGS SHALL SHOW ALL WELDING WITH AWS A2.4 SYMBOLS. ALL
WELDING SHALL BE DONE BY AWS CERTIFIED WELDERS AND IN ACCORDANCE
WITH AWS D1.1. WELDS SHOWN ON THE DRAWINGS ARE THE MINIMUM SIZES.
MINIMUM WELDING SHALL BE 6mm (1/4"). ALL PARTIAL PENETRATION GROOVE
WELD SIZES SHOWN ON THE DRAWINGS REFER TO EFFECTIVE THROAT
THICKNESS. ALL WELDS SHALL BE MADE USING LOW -HYDROGEN ELECTRODES
WITH MINIMUM TENSILE STRENGTH = 490 MPa (71 ksi). WELDING PROCEDURES
SHALL BE SUBMITTED TO THE CONTRACTING OFFICER FOR REVIEW BEFORE
STARTING FABRICATION OR ERECTION. ALL COMPLETE-PENETRATION WELDS
SHALL BE ULTRASONICALLY TESTED. REDUCTION IN TESTING MAY BE MADE IN
ACCORDANCE WITH THE BUILDING CODE WITH APPROVAL OF CONTRACTING
OFFICER.
ALL EXPOSED STEEL SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A 123.
ALL SURFACES OF GALVANIZED STEEL SHALL BE APPLIED WITH THREE-LAYERED
PAINT COATING. CONSIDER MEMBRANE TYPE PAINT (NOT LATEX), OR HIGH SOLIDS
EPOXY FOR BEST RESULTS. ELECTROPLATING OR CADMIUM PLATING IS NOT
PERMITTED.
MINIMUM CONNECTIONS SHALL BE A TWO-BOLT CONNECTION USING 19mm (3/4")
DIAMETER A325 BOLTS IN SINGLE SHEAR.
ALL HIGH-STRENGTH BOLTS SHALL BE INSTALLED, TIGHTENED AND INSPECTED IN
ACCORDANCE WITH THE AISC SPECIFICATION FOR STRUCTURAL JOINTS USING
ASTM A325 OR A490 BOLTS. THE CRITERIA FOR SLIP-CRITICAL CONNECTIONS
SHALL APPLY TO ALL CONNECTIONS UNLESS SPECIFICALLY NOTED AS
SNUG-TIGHT ON THE STRUCTURAL DRAWINGS. WHERE CONNECTIONS ARE NOTED
AS SNUG-TIGHT, THE CONTRACTOR MAY INSTALL PER CRITERIA FOR SNUG-TIGHT
BOLTS. SLIP-CRITICAL CONNECTIONS SHALL USE LOAD INDICATOR WASHERS OR
TENSION CONTROL BOLTS. ALL ASTM A307 BOLTS SHALL BE PROVIDED WITH LOCK
WASHERS UNDER NUTS OR SELF-LOCKING NUTS. ALL BOLT HOLES SHALL BE
STANDARD SIZE, UNLESS NOTED OTHERWISE.
MINIMUM FILLET WELD SIZE SHALL BE 6mm (1/4") UNLESS NOTED ON DRAWINGS.
MIN PLATE THICKNESS SHALL BE 9.5mm (3/8") U.N.O.
THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR ALL ERECTION AIDS AND
JOINT PREPARATIONS THAT INCLUDE, BUT ARE NOT LIMITED TO: ERECTION
ANGLES, LIFT HOLES, AND OTHER AIDS; WELDING PROCEDURES; REQUIRED ROOT
OPENINGS; ROOT FACE DIMENSIONS; GROOVE ANGLES; BACKING BARS; COPES;
SURFACE ROUGHNESS VALUES; AND TAPERS OF UNEQUAL PARTS.
ALL STRUCTURAL STEEL ERECTION SHALL BE IN ACCORDANCE WITH OSHA, CFR
1926 SUBPART R - STRUCTURAL STEEL ERECTION.
HOLES CAN BE DRILLED THRU THE SPALL PLATE IN THE WALL OR ROOF SECTIONS
AS REQURED FOR FORMWORK SUPPORT. HOWEVER, THE HOLES MUST REMAIN 6
INCHES AWAY FROM ANY WELDED LOCATION. THE INTERIOR EDGE OF THE TIE
HOLES SHALL BE APPLIED WITH A ZINC COATING BEFORE THEY ARE FILLED WITH
CEMENTITIOS MATERIAL.
SPALL PLATES (3/8" THICK STEEL PLATES) WITH 3/4" Ø HEADED STUDS (8" LONG)
AT 12" ON CENTER BOTH WAYS (UNLESS SPACING INDICATED ON DRAWINGS)
SHALL BE PROVIDED FOR INTERIOR FACE OF ALL EXTERIOR LOAD-BEARING WALLS
AND BOTTOM FACE OF LOWER ROOF SLAB. BOTH VERTICAL AND HORIZONTAL
JOINTS BETWEEN SPALL PLATES SHALL BE FULL-PENETRATION WELDED.
CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE BUILDING
CODE. ALL HOLLOW LOAD BEARING CONCRETE MASONRY UNITS SHALL
CONFORM TO ASTM C 90, GRADE N-1. ALL CELLS SHALL BE FILLED SOLID
WITH CONCRETE GROUT. GROUT MIX SHALL CONTAIN PORTLAND CEMENT
ONLY PLUS AGGREGATE PLUS A NON-SHRINK ADDITIVE. MAXIMUM SIZE
OF AGGREGATE SHALL BE 9.5mm (3/8"). SLUMP SHALL BE 203mm (8") TO 280mm (11"). WATER-REDUCING ADMIXTURES MAY BE USED. MINIMUM
COMPRESSIVE STRENGTH OF GROUT BASED ON 28 DAY TESTS SHALL BE
17.2 MPa (2500 psi). GROUT SHALL BE VIBRATED WHILE PLACING TO
INSURE THAT CELLS ARE COMPLETELY FILLED. SUBMIT GROUT MIXES TO
CONTRACTING OFFICER FOR REVIEW BEFORE COMMENCING MASONRY
CONSTRUCTION. ALL UNITS SHALL BE LAID IN RUNNING BOND USING TYPE
M MORTAR WITH HEAD JOINTS.
THE DUROWALL HORIZ JOINT REINFORCEMENT SHALL BE HOT-DIP
GALVANIZED WITH 4.762mm ( 3
16") DIAMETER SIDE RODS.
ALL STEEL SHALL CONFORM TO THE FOLLOWING:
STEEL W-SHAPES ASTM A36, Fy=252 MPa (36 ksi) OR ASTM A992, Fy=345 MPa (50 ksi)
ALL PLATES, ANGLES, CHANNELS ASTM A36, FY = 252 MPa (36 ksi)
SQUARE OR RECTANGULAR
STRUCTURAL TUBE
ASTM A500, GRADE B, FY = 322 MPa (46 ksi)
STEEL PIPE DIAMETER 305mm (1'-0")
ASTM A500, GRADE B, FY = 290 MPa (42 ksi)
ANCHOR BOLTS ASTM F1554, GRADE 55 (GALVANIZED PER
ASTM A153)
STUD CONNECTORS ASTM A108, GRADE 1010 THRU 1020, 350
MPa (50 ksi) YIELD
REQUIRED MORTAR PROPORTIONS BY VOLUME
TYPE PORTLAND CEMENT
AGGREGATE MEASURED IN A DAMP,
LOOSE CONDITION
S TYPE 1
NOT LESS THAN 2-1/4 AND NOT MORE
THAN 3 TIMES THE CEMENT VOLUME
STRUCTURAL DESIGN DATA:
LIVE LOADS:
ROOF: 0.96 kPa (20 psf), BLAST LOAD (CLASSIFIED)
CEILING LOAD: 0.478 kPa (10 psf)
CORRIDORS, WALKWAYS 4.78 kPa (100 psf)
MECH./ELEC. ROOMS: 6.00 kPa (125 psf) OR ACTUAL WEIGHT OF
EQUIPMENTS HOUSED
OFFICE FLOORS 2.40 kPa (50 psf) OR 8.9 kN (2 kip) CONCENTRATED
LOAD WHICHEVER PRODUCES THE GREATER
LOAD EFFECTS; PARTITION ON SUSPENDED
FLOORS: 0.5 kPa (10 psf)
WIND LOADS (ASCE 7-10): ULTIMATE DESIGN WIND SPEED FOR MAIN
FORCE-RESISTING SYSTEM: 94 m/sec (210 mph)
ULTIMATE WIND SPEED FOR COMPONENTS:
105 m/sec (235 mph)
EXPOSURE CATEGORY "C"
INTERNAL PRESSURE COEFFICIENT (GCpi) FOR
INTERIOR COMPONENTS BASED ON ENCLOSED
BUILDING PER ASCE 7-10 TABLE 26.11-1.
SEISMIC LOADS: SEISMIC LOADING SHALL BE IN ACCORDANCE
WITH IBC 2015 AND ASCE 7-10.
RISK CATEGORY: IV
SEISMIC FACTOR: 1.5
SITE CLASS: C (PER SOIL
REPORT)
S : 2.79g
S : 0.68g
S : 1.9g
S : 0.59g
SEISMIC DESIGN CATEGORY: D
S
EPOXY GROUT:
ACCEPTABLE DRILLED-IN CONCRETE ANCHORS OF SIZE, NUMBER, AND
SPACING AS SHOWN ON THE DRAWINGS, SHALL BE AS FOLLOWS: HILTI
KWIK BOLT TZ, OR APPROVED EQUAL. MINIMUM EMBEDMENT DEPTH SHALL BE 6
BOLT DIAMETERS AND PER MANUFACTURER'S TEST DATA CONSIDERING
GROUP EFFECTS, ETC., UNLESS OTHERWISE NOTED ON DRAWINGS. ALL
POST-INSTALLED STRUCTURAL ANCHORS SHALL HAVE PASSED THE
SIMULATED SEISMIC TESTS OF ACI 355.2.
"EPOXY GROUT" SHALL BE A 100 PERCENT SOLIDS PASTE DESIGNED FOR
STRUCTURAL BONDING OF DOWELS IN HARDENED CONCRETE. WHEN MIXED
AND CURED ACCORDING TO THE MANUFACTURER'S WRITTEN INSTRUCTIONS,
EPOXY MATERIALS SHALL PRODUCE THE FOLLOWING PROPERTIES:
COMPRESSIVE STRENGTH (ASTM D695) = 70MPa (10 ksi), TENSILE STRENGTH (ASTM D638) = 24.5 MPa (3.5 ksi).
"EPOXY GROUT" SHALL BE USED FOR ALL DRILLED AND GROUTED
REINFORCING BARS OR BOLTS UNLESS NOTED OTHERWISE. EPOXY GROUT
SHALL BE "PROPOXY 300 AS DISTRIBUTED BY BONDED MATERIALS COMPANY,"
OR APPROVED EQUAL. SUBMIT MANUFACTURER'S LITERATURE TO THE
CONTRACTING OFFICER FOR APPROVAL.
EPOXY MATERIAL SHALL BE MIXED, APPLIED AND CURED IN STRICT
ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS. ALL
PLACEMENT AND CURING SHALL BE CONDUCTED WITH CONCRETE AND AIR
TEMPERATURES ABOVE 50 DEGREES. APPLY EPOXY MATERIAL ONLY TO CLEAN,
DRY CONCRETE.
EPOXY ANCHORAGE FOR BOLTS IN PURE TENSION ALONE SHALL BE
PROHIBITED. PRINCIPAL SUPPORT BY EPOXY BOLTS SHALL BE IN SHEAR.
MIXING OF EPOXY SHALL BE DONE WITH NOZZLES NOT MANUALLY.
PRECAST CONCRETE:
REFER TO ARCHITECTURAL DRAWINGS FOR OPENINGS, DETAILS, AND
DIMENSIONS NOT SHOWN. HORIZONTAL PRECAST MEMBERS SHALL BE
CAST, STRESSED, TRANSPORTED, AND ERECTED IN A HORIZONTAL,
UPRIGHT POSITION. SUPPORTS DURING TRANSPORTATION AND ERECTION
SHALL APPROXIMATE THOSE IN THE FINAL STRUCTURE. WHERE
NECESSARY, THE CONTRACTOR SHALL PROVIDE AND INSTALL
ADDITIONAL REINFORCING (STEEL STIFFENERS, BRACING, LIFTING
INSERTS, ETC.) TO RESIST ERECTION AND TRANSPORTATION STRESSES.
LIFTING INSERTS SHALL BE INSTALLED AT LOCATIONS WHERE THEY WILL
BE HIDDEN BY CONSTRUCTION OR OTHERWISE COVERED. FINISH ALL
PANELS WHICH WILL BE COVERED WITH TOPPING SLABS WITH 4MM
AMPLITUDE ROUGHED BROOM FINISH TO INSURE BONDING OF THE
CONCRETE TOPPING. SUBMIT DETAILED SHOP DRAWINGS OF ALL
PRECAST CONCRETE WORK TO THE CONTRACTING OFFICER FOR REVIEW
BEFORE STARTING FABRICATION.
ALL PRECAST PLANKS SHALL HAVE MID-SPAN SHORING ADJUSTED TO
SPECIFIED PRE CAMBERS DURING ERECTION AND BEFORE RECEIVING
CONCRETE TOPPING.
MINIMUM COMPRESSIVE STRENGTH OF CONCRETE AT DETENSIONING OF
PRESTRESSING STRANDS SHALL BE 35 MPa (5000 psi).
GENERAL NOTES (CONT'D.)
DS
DRILLED-IN CONCRETE ANCHORS (DICA):
NON-STRUCTURAL COMPONENTS SUSPENDED FROM HARDENED (LOWER) ROOF SLAB:
1. REFER TO NOTE 6 ON DRAWING G-001 FOR REQUIRED DESIGN HANGER
FORCES.
2. POST-INSTALLED ANCHORS ARE NOT ALLOWED FOR SUSTAINED TENSION
LOADS. ALL ANCHORS MUST BE EMBEDDED BOLTS OR RODS CAST IN CONC.
ANCHOR BOLTS OR RODS SHALL BE HEADED TYPE WITH MIN 16mm (5 8") DIAMETER AND MIN 457mm (18") EMBEDMENT LENGTH.
3. CONTRACTOR SHALL SUBMIT DESIGN FOR CONTRACTING OFFICER'S REVIEW
AND APPROVAL.
D1
ALL WORK SHALL BE IN ACCORDANCE WITH THE AISC SPECIFICATION. SHOP
DRAWINGS SHALL BE SUBMITTED AND REVIEWED BY THE CONTRACTING OFFICER
BEFORE COMMENCING FABRICATION. ALL STEEL ANCHORS AND TIES AND OTHER
MEMBERS EMBEDDED IN CONCRETE OR MASONRY SHALL BE LEFT UNPAINTED.
DIMENSIONAL TOLERANCE FOR BUILT-UP MEMBERS SHALL BE PER AWS D1.1.
ASTM A6 GROUP 4 AND 5 ROLLED SHAPES AND PLATES EXCEEDING 50mm
(2") THICKNESS USED FOR BUILT-UP MEMBERS REQUIRE CHARPY V-NOTCH
TESTING IN ACCORDANCE WITH ASTM A6 SUPPLEMENTARY REQUIREMENT S5,
WHERE FULL-PENETRATION WELDS ARE CALLED OUT AT EITHER END OF THE
MEMBER ON THE DRAWINGS. REFER TO AISC SPECIFICATION, PARAGRAPH A3.C
FOR TESTING STANDARDS.
FLOOR OR PAD-MOUNTED MISSION-CRITICAL EQUIPMENT SHOULD USE
CAST-IN-PLACE ANCHOR BOLTS TO ANCHOR THEM. ALTERNATIVELY,
POST-INSTALLED ANCHORS ARE PERMITTED TO BE USED PROVIDED THEY ARE
QUALIFIED FOR EARTHQUAKE LOADING IN ACCORDANCE WITH ACI 355.2,
QUALIFICATION OF POST-INSTALLED MECHANICAL ANCHORS IN CONCRETE, AND
ACI 355.4, ACCEPTANCE CRITERIA FOR QUALIFICATION OF POST-INSTALLED
ADHESIVE ANCHORS IN CONCRETE, AS APPLICABLE. FOR THIS EQUIPMENT. TWO
NUTS SHOULD BE PROVIDED ON EACH BOLT. CAST-IN-PLACE ANCHOR BOLTS
SHOULD HAVE AN EMBEDDED STRAIGHT LENGTH EQUAL TO AT LEAST 12 TIMES
THE NOMINAL BOLT DIAMETER. ANCHOR BOLTS THAT EXCEED THE NORMAL
DEPTH OF EQUIPMENT PADS SHOULD EXTEND INTO THE CONCRETE FLOOR TO
ACCOMMODATE THE BOLT LENGTHS.
BASE-MOUNTED EQUIPMENT
BID SCHEDULE FOR STRUCTURAL WORK
BIDS SHEETS EXCLUDED DETAILS EXCLUDED
BASE BID S-105 & S-503 2/S-202, 2/S-401, 3/S-401, 4/S-401,
9/S-401, 7/S-401
BID OPTIONS 1, 2, & 3 N/A N/A
NOTES:
1. BASE BID EXCLUDES UPPER ROOF FRAMING (HIP ROOF SLAB & GUTTERS,
PILASTERS FOR GUTTERS, RIDGE BEAMS, HIP BEAMS AND CONCRETE TRUSSES
ABOVE DIAPHRAGM ELEVATION 8535 (28'-0") ).
2. BID OPTIONS 1, 2, & 3 INCLUDE EVERYTHING SHOWN ON DRAWINGS.
3. FOR BASE BID, REFER ARCHITECTURAL DRAWINGS FOR TOP OF ROOF
PARAPET ELEVATION ALONG THE PERIMETERS.
S-002
G
EN
ER
AL
N O
TE
S
17195924
JACOBS/BURNS & MCDONNELL, A JOINT VENTURE
155 NORTH LAKE AVENUE
PASADENA, CA 91101 USA
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE
AP
R
IN
ST
AL
LA
TI
ON
C
ON
TR
OL
C
EN
TE
R
FY
M
CA
F
PR
OJ
EC
T P-
0/A
JJ
Y1
JR
M
- A
ND
ER
SE
N
AI
R
FO
RC
E
BA
SE
GU
AM
, M
AR
IA
NA
IS
LA
ND
S
NA
VF
AC
M
AR
IA
NA
S
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
JR
M-
AN
DE
RS
EN
A
IR
F
OR
CE
B
AS
E
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
M
AR
IA
N
AS
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
1 2 3 4 5
D
C
B
A
1 2 3 4 5
D
C
B
A
BZ ZKS AAY
SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON FULL SIZE ANSI D (22" x 34") SHEET.
AS SHOWN
JEG NO. FDWD7921
1342285
C
FIRE PROTECTION
FO
R
OF
FI
CI
AL
U
SE
O
NL
Y (F
OU
O)
GENERAL NOTES (CONT'D.)
NO. INSPECTION FREQUENCY CONT PERIODIC
4 INSPECTION OF ANCHORS INSTALLED IN HARDENED
CONCRETE. X
5 VERIFYING USE OF REQUIRED DESIGN MIX. X
AT THE TIME FRESH CONCRETE IS SAMPLED TO
FABRICATE SPECIMENS FOR STRENGTH TESTS,
PERFORM SLUMP AND AIR CONTENT TESTS, AND
DETERMINE THE TEMPERATURE OF THE CONCRETE.
X
7 INSPECTION OF CONCRETE PLACEMENT FOR
PROPER APPLICATION TECHNIQUES X X
8 INSPECTION FOR MAINTENANCE OF SPECIFIED
CURING TEMPERATURE AND TECHNIQUES X
9 INSPECTION OF PRESTRESSED CONCRETE:
A. APPLICATION OF PRESTRESSING FORCES. X
10 ERECTION OF PRECAST CONCRETE MEMBERS. X
VERIFICATION OF IN-SITU CONCRETE STRENGTH,
PRIOR TO PRESTRESS RELEASE IN PRE-TENSIONED
CONCRETE AND PRIOR TO REMOVAL OF SHORES
AND FORMS FROM STRUCTURAL MEMBERS.
X
INSPECT FORMWORK FOR SHAPE, LOCATION AND
DIMENSIONS OF THE CONCRETE MEMBER BEING
FORMED.
X
13 INSTALLATION OF TYPE 2 MECH SPLICE X
14 CONSTRUCTION SEQUENCE PER DESIGN
DOCUMENTS X
15 EPOXY AND MECHANICAL ANCHORS INSTALLATION
TO CONCRETE AND MASONRY X
INSPECTION OF SOILS
VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS
ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING
CAPACITY.
X
2 VERIFY EXCAVATIONS ARE EXTENDED TO PROPER
DEPTH AND HAVE REACHED PROPER MATERIAL. X
3 PERFORM CLASSIFICATION AND TESTING OF
COMPACTED FILL MATERIALS. X
VERIFY USE OF PROPER MATERIALS, DENSITIES AND
LIFT THICKNESS DURING PLACEMENT AND
COMPACTION OF COMPACTED FILL.
X
PRIOR TO PLACEMENT OF COMPACTED FILL,
OBSERVE SUBGRADE AND VERIFY THAT SITE HAS
BEEN PREPARED PROPERLY.
X
SEISMIC RESISTANCE
1 SUSPENDED CEILING SYSTEM AND THEIR
ANCHORAGE X
2 STEEL STORAGE RACKS AND THEIR ANCHORAGE X
3 ACCESS FLOOR AND THEIR ANCHORAGE X
4 ANCHORAGE OF ELECTRICAL EQUIPMENT FOR
EMERGENCY OR STAND-BY POWER SYSTEMS X
5 ANCHORAGE OF NON-EMERGENCY ELECTRICAL
EQUIPMENT X
INSTALLATION OF PIPING SYSTEMS AND
ASSOCIATED MECHANICAL UNITS CARRYING
FLAMMABLE, COMBUSTIBLE, OR HIGHLY TOXIC
CONTENTS
X
7 INSTALLATION OF HVAC DUCTWORK THAT CONTAINS
HAZARDOUS MATERIALS X
EQUIPMENT LABEL AND ANCHORAGE OR MOUNTING
CONFORMS TO THE CERTIFICATE OF COMPLIANCE
WHEN MECHANICAL AND ELECTRICAL EQUIPMENT
MUST BE SEISMICALLY QUALIFIED
X
ERECTION AND FASTENING OF NON-BEARING WALLS
WEIGHING MORE THAN 73 KG/M² (15 LB/FT²) X
10 INSTALLATION OF PRECAST STRUCTURAL FINS AND
ANCHORAGE X
MASONRY - LEVEL (2)
COMPLIANCE WITH REQUIRED INSPECTION
PROVISIONS OF THE CONSTRUCTION DOCUMENTS
AND THE APPROVED SUBMITTALS.
X
VERIFICATION OF f'm AND f'aac PRIOR TO
CONSTRUCTION AND FOR EVERY 464.5 M² (5,000 FT²)
DURING CONSTRUCTION.
X
VERIFICATION OF PROPORTIONS OF MATERIALS IN
PREMIXED OR PREBLENDED MORTAR AND GROUT
AS DELIVERED TO THE SITE.
X
VERIFICATION OF SLUMP FLOW AND VSI AS
DELIVERED TO THE SITE FOR SELF-CONSOLIDATING
GROUT
X
5 THE FOLLOWING SHALL BE VERIFIED TO ENSURE
COMPLIANCE:
NO. INSPECTION FREQUENCY CONT PERIODIC
A. PROPORTIONS OF SITE-PREPARED MORTAR,
GROUT AND PRESTRESSING GROUT FOR BONDED
TENDONS.
X
B. PLACEMENT OF MASONRY UNITS AND
CONSTRUCTION OF MORTAR JOINTS. X
C. PLACEMENT OF REINFORCEMENT, CONNECTORS
AND PRESTRESSING TENDONS AND
ANCHORAGES.
X
D. GROUT SPACE PRIOR TO GROUT. X
E. PLACEMENT OF GROUT. X
F. SIZE AND LOCATION OF STRUCTURAL ELEMENTS. X
G. TYPE, SIZE AND LOCATION OF ANCHORS,
INCLUDING OTHER DETAILS OF ANCHORAGE OF
MASONRY TO STRUCTURAL MEMBERS, FRAMES
OR OTHER CONSTRUCTION.
X
H. SPECIFIED SIZE, GRADE AND TYPE OF
REINFORCEMENT, ANCHOR BOLTS X
6 PREPARATION OF ANY REQUIRED GROUT
SPECIMENS AND/OR PRISMS SHALL BE OBSERVED. X
SPECIAL INSPECTION:
THE FOLLOWING ITEMS REQUIRE SPECIAL INSPECTION PER IBC 2015
CHAPTER 17. CONFORM WITH INSPECTION REQUIREMENTS FOR STEEL
CONSTRUCTION PER AISC 360-10 (CHAPTER N - QUALITY CONTROL AND
QUALITY ASSURANCE). THESE INSPECTIONS SHALL BE PERFORMED BY
Q.C SPECIALISTS AND/OR ICBO CERTIFIED INSPECTORS.
THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO SHALL
DEMONSTRATE COMPETENCE, TO THE SATISFACTION OF THE
CONTRACTING OFFICER, FOR THE INSPECTION OF THE PARTICULAR TYPE
OF CONSTRUCTION OR OPERATION REQUIRING SPECIAL INSPECTION.
PERFORM THE TYPES OF INSPECTIONS SPECIFIED. SEE THE
SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS FOR SPECIAL
INSPECTION AND TESTING.
NO. INSPECTION FREQUENCY CONT PERIODIC
STEEL CONSTRUCTION
1 MATERIAL VERIFICATION OF HIGH-STRENGTH BOLTS,
NUTS, WASHERS AND HEADED STUDS:
A. IDENTIFICATION MARKINGS TO CONFORM TO
ASTM STANDARDS SPECIFIED IN THE APPROVED
CONSTRUCTION DOCUMENTS
X
B. MANUFACTURER’S CERTIFICATE OF COMPLIANCE
REQUIRED. X
2 INSPECTION OF HIGH-STRENGTH BOLTING:
A. SNUG-TIGHT JOINTS X
B. PRETENSIONED AND SLIP-CRITICAL JOINTS USING
TURN-OF-NUT WITH MATCHMARKING, TWIST-OFF
BOLT OR DIRECT TENSION INDICATOR METHODS OF
INSTALLATION
X
C. PRETENSIONED AND SLIP-CRITICAL JOINTS USING
TURN-OF-NUT WITHOUT MATCHMARKING OR
CALIBRATED WRENCH METHODS OF INSTALLATION
X
3 MATERIAL VERIFICATION OF STRUCTURAL STEEL:
A. FOR STRUCTURAL STEEL, IDENTIFICATION
MARKINGS TO CONFORM TO AISC 360 X
B. FOR OTHER STEEL, IDENTIFICATION MARKINGS TO
CONFORM TO ASTM STANDARDS SPECIFIED IN THE
APPROVED CONSTRUCTION DOCUMENTS
X
C. MANUFACTURER’S CERTIFIED TEST REPORTS X
4 MATERIAL VERIFICATION OF WELD FILLER
MATERIALS:
A. IDENTIFICATION MARKINGS TO CONFORM TO AWS
SPECIFICATION IN THE APPROVED CONSTRUCTION
DOCUMENTS
X
B. MANUFACTURER’S CERTIFICATE OF COMPLIANCE
REQUIRED X
5 INSPECTION OF WELDING:
A. STRUCTURAL STEEL
1) COMPLETE AND PARTIAL JOINT PENETRATION
GROOVE WELDS X
2) MULTIPASS FILLET WELDS X
3) SINGLE-PASS FILLET WELDS GREATER THAN 8MM
(5/16") X
4) SINGLE-PASS FILLET WELDS LESS THAN OR
EQUAL TO 8MM (5/16") X
B. REINFORCING STEEL:
1) VERIFICATION OF WELDABILITY OF REINFORCING
STEEL OTHER THAN ASTM A 706 X
2) REINFORCING STEEL RESISTING FLEXURAL AND
AXIAL FORCES IN INTERMEDIATE AND SPECIAL
MOMENT FRAMES, AND BOUNDARY ELEMENTS OF
SPECIAL STRUCTURAL WALLS OF CONCRETE AND
SHEAR REINFORCEMENT
X
3) SHEAR REINFORCEMENT X
4) OTHER REINFORCING STEEL, HEADED STUDS X
6 INSPECTION OF STEEL FRAME JOINT DETAILS FOR
COMPLIANCE:
A. DETAILS SUCH AS BRACING AND STIFFENING X
B. MEMBER LOCATIONS X
C. APPLICATION OF JOINT DETAILS AT EACH
CONNECTION X
CONCRETE CONSTRUCTION
1 INSPECTION OF REINFORCING STEEL, INCLUDING
PRESTRESSING TENDONS, AND PLACEMENT. X
INSPECTION OF REINFORCING STEEL WELDING IN
ACCORDANCE WITH INSPECTION FOR STEEL
CONSTRUCTION
INSPECTION OF BOLTS TO BE INSTALLED IN
CONCRETE PRIOR TO AND DURING PLACEMENT OF
CONCRETE
X
FOUNDATION NOTES
1. FOOTING EXCAVATION
DURING CONSTRUCTION, THE FOLLOWING FOOTING EXCAVATION AND
RECOMPACTION PROCEDURES SHOULD BE FOLLOWED.
(A) WHERE THE FOOTING EXCAVATION EXPOSES HARD CORALLINE
LIMESTONE ROCK MASS (NOT BOULDERS), THE EXCAVATION MAY BE
TERMINATED AFTER REACHING THE DESIGNED FOOTING DEPTH,
PROVIDED THE HARD ROCK IS VERIFIED BY THE GEOTECHNICAL
ENGINEER. IF THE EXPOSED ROCK SURFACE IS HARD AND UNEVEN,
LEVEL IT WITH LEAN CONCRETE OR SAND-CEMENT MIXTURE HAVING AT
LEAST 1000 PSI (POUNDS PER SQUARE INCH) 28-DAY COMPRESSIVE
STRENGTH. THE LEVELING PROCEDURE SHOULD BE PERFORMED
SEPARATELY AND BEFORE PLACING REINFORCING STEEL BARS AND
FOUNDATION CONCRETE.
(B) IF THE EXPOSED SURFACE IS WEAK TO VERY WEAK, NATIVE
CORALLINE LIMESTONE TESTED TO BE LESS THAN 100 PERCENT OF ITS
MAXIMUM DRY DENSITY, IT SHOULD BE CAREFULLY EXCAVATED UNTIL
THE EXPOSED SURFACE IS TESTED TO HAVE 100 PERCENT OF ITS
MAXIMUM DRY DENSITY TO BE VERIFIED BY THE GEOTECHNICAL
ENGINEER. HOWEVER, THE MAXIMUM DEPTH OF THIS EXCAVATION CAN
BE LIMITED TO 1.5 TIMES THE FOOTING WIDTH DIRECTLY ABOVE,
BELOW THE FOOTING BOTTOM. THEREAFTER, SCARIFY AND LEVEL THE
EXPOSED, APPROXIMATELY 6 INCHES, MOISTURE CONDITION AS
NECESSARY AND COMPACT TO AT LEAST 95 PERCENT OF ITS MAXIMUM
DRY DENSITY WITH A UNIFORM, DENSE AND UNYIELDING SURFACE.
THEN BACKFILL WITH APPROVED LIMESTONE SAND/GRAVEL SOIL IN
8-INCH LOOSE LAYERS; MOISTURE CONDITION THE BACKFILL SOIL AS
NECESSARY AND COMPACT TO 100 PERCENT OF ITS MAXIMUM DRY
DENSITY WITH A UNIFORM, DENSE, AND NONYIELDING SURFACE.
HOWEVER, COMPACTION OF THE BACKFILL MORE THAN 3 FEET BELOW
THE FOOTING BOTTOM CAN BE 95 PERCENT OF ITS MAXIMUM DRY
DENSITY.
THE ABOVE FOOTING SUBGRADE IMPROVEMENT SHOULD EXTEND AT
LEAST TWO FEET WIDER BEYOND THE EDGES OF THE FOOTINGS, OR
ONE FOOT WIDER IF THE FOOTING WIDTH IS LESS THAN 3 FEET.
THE FOOTING EXCAVATED SOILS CONSISTING OF LIMESTONE
SAND/GRAVEL SOILS MEETING THE BACKFILL SOIL REQUIREMENTS MAY
BE REUSED FOR THE ABOVE BACKFILL.
(C) WHERE THE FOOTING EXCAVATION EXPOSES MODERATELY HARD
CORALLINE LIMESTONE OR DENSE TO VERY DENSE SILTY LIMESTONE
SAND/GRAVEL TESTED TO HAVE 100 PERCENT OF ITS MAXIMUM DRY
DENSITY, TO BE VERIFIED BY THE GEOTECHNICAL ENGINEER. THE
EXCAVATION MAY BE TERMINATED.
IF THE TEST RESULT IS LESS THAN 100 PERCENT MAXIMUM DRY
DENSITY, EXCAVATE FURTHER UNTIL HITTING 100 PERCENT MAXIMUM
DRY DENSITY OR A MAXIMUM OF 3 FEET BELOW THE FOOTING BOTTOM,
AND APPLY THE PROCEDURE DESCRIBED IN ITEM (B) ABOVE FOR
BACKFILLING.
AS AN OPTION, BACKFILL FOR FOOTING EXCAVATIONS CAN BE
CONCRETE FLOWABLE FILL HAVING AT LEAST 1000 PSI, 28-DAY
COMPRESSIVE STRENGTH THAT WILL HARDEN WITHIN 12 HOURS
AFTER PLACEMENT.
2. FOUNDATION PROBES
DRILLING PROBE HOLES AT BUILDING FOOTING BOTTOMS TO DETECT
ANY SIGNIFICANT SIZE CAVITIES OR WEAK SOIL POCKETS.
THERE SHOULD BE ONE PROBE HOLE TO BE DRILLED AT EACH INDIVIDUAL FOOTING
BOTTOM FOR EACH 225 SQUARE FEET OF FOOTING AREA AND REMAINING BALANCE
OF EACH FOUNDATION FOOTING, AND AT LEAST ONE PROBE FOR FOOTINGS
SMALLER THAN 225 SQUARE FEET. THE PROBES SHOULD BE DRILLED TO 30 FEET
DEEP BELOW THE FOOTING BOTTOM. FOR CONTINUOUS FOOTINGS, DRILL PROBE
HOLES AT 10-FOOT CENTERS, APPROXIMATELY ALONG THE CENTER LINES OF THE
CONTINUOUS FOOTINGS, ALL TO MINIMUM 20 FEET BELOW THE CONTINUOUS
FOOTING BOTTOMS. IF CAVITY IS FOUND, ADDITIONAL PROBE DRILLING MAY BE
NEEDED TO DETERMINE THE EXTENT OF THE CAVITIES.
SIGNIFICANT CAVITIES, IF ENCOUNTERED, SHOULD BE GROUT BACKFILLED UNDER
AT LEAST 40 PSI AIR PRESSURE. WEAK SOIL OR SILT POCKETS THAT WILL AFFECT
THE FOUNDATION PERFORMANCE SHOULD BE EXCAVATED AND REPLACED WITH
FLOWABLE FILL AT LEAST 1000 PSI AT 28-DAY AGE, OR SUITABLE BACKFILL
COMPACTED TO AT LEAST 95 PERCENT OF ITS MAXIMUM DRY DENSITY. THE
REMAINING PROBE HOLES SHOULD BE BACKFILLED WITH HIGH SLUMP
SAND-CEMENT MIXTURE OR LOW STRENGTH CONCRETE WITH AT LEAST 1000 PSI
28-DAY COMPRESSIVE STRENGTH; THE BACKFILL CAN BE POURED INTO THE PROBE
HOLES RATHER SLOWLY BY GRAVITY FROM ONE SIDE OF THE PROBE HOLES TO
AVOID TRAPPING AIR, AND THE VOLUME OF EACH PROBE HOLE BACKFILL SHOULD
BE CHECKED TO VERIFY THAT THE PROBE HOLES ARE FULLY BACKFILLED.
THE PROBE DRILLING AND BACKFILLING SHOULD BE PERFORMED UNDER FULL TIME
INSPECTION OR SUPERVISION OF A QUALIFIED GEOTECHNICAL ENGINEER OR
GEOLOGIST, OR HIS REPRESENTATIVE. PROBE DRILLING RECORDS SUCH AS DRILL
RATES (IN MINUTES PER FOOT DRILLED), DRILLING BEHAVIOR, OBSERVATION OF
DRILL CUTTINGS, AND AMOUNT OF CEMENT GROUT AND/OR FLOWABLE FILL FOR
BACKFILLING EACH PROBE HOLE, SHOULD BE EVALUATED BY THE GEOTECHNICAL
ENGINEER.
3. MINIMUM FOOTING EMBEDMENT BELOW LOWEST ADJACENT FINAL GRADE IS 3
FEET.
4. SLAB ON GRADE (GROUND FLOOR SLAB)
THE CONCRETE ON-GRADE SLABS SHOULD BE UNDERLAIN WITH 6 INCHES THICK OF
DENSELY COMPACTED, AGGREGATE BASE COURSE HAVING AT LEAST 98 PERCENT
OF ITS MAXIMUM DRY DENSITY. ALTERNATIVELY, THE SLABS MAY BE UNDERLAIN
WITH 4-INCH THICK OF 3/4-INCH MAXIMUM SIZE CONCRETE COARSE AGGREGATE,
UNIFORMLY SPREAD, MOISTURE CONDITIONED AS NECESSARY AND COMPACTED
TO DENSE AND NONYIELDING EQUIVALENT TO 98 PERCENT OF ITS MAXIMUM DRY
DENSITY.
THE BASE COURSE OR AGGREGATE SHOULD BE COVERED WITH A 15 MIL VAPOR
BARRIER (AGAINST MOISTURE MIGRATION) BEFORE PLACING CONCRETE.
5. DESIGN PARAMETERS:
1.) ALLOWABLE SUBGRADE BEARING PRESSURES
DEAD PLUS LIVE LOADS 4000 PSF
(PSF = POUNDS PER SQUARE FOOT)
TOTAL DESIGN LOADS, INCLUDING 5330 PSF
WIND OR SEISMIC FORCES
2.) RESISTANCE TO LATERAL LOADS
FRICTION ACROSS FOOTING BOTTOMS (PERCENT
OF DEAD LOADS AT FOOTING BOTTOMS) 35
PASSIVE SOIL RESISTANCE AGAINST ONE FACE
OF THE FOOTINGS (UNIFORM WITH DEPTH FOR
DENSELY COMPACTED SAND/GRAVEL SOILS
AROUND THE FOOTINGS. IGNORE TOP ONE FOOT
IF IT IS NOT DIRECTLY COVERED WITH CONCRETE
SLAB OR ASPHALT PAVEMENT), 1000 PSF
3.) MODULUS OF SUBGRADE REACTION 600 KCF
(KCF = KIPS PER SQUARE FOOT PER FOOT OF
DEPTH OR KIPS PER CUBIC FOOT)
S-003
G
EN
ER
AL
N O
TE
S
17195925
JACOBS/BURNS & MCDONNELL, A JOINT VENTURE
155 NORTH LAKE AVENUE
PASADENA, CA 91101 USA
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE
AP
R
IN
ST
AL
LA
TI
ON
C
ON
TR
OL
C
EN
TE
R
FY
M
CA
F
PR
OJ
EC
T P-
0/A
JJ
Y1
JR
M
- A
ND
ER
SE
N
AI
R
FO
RC
E
BA
SE
GU
AM
, M
AR
IA
NA
IS
LA
ND
S
NA
VF
AC
M
AR
IA
NA
S
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
JR
M-
AN
DE
RS
EN
A
IR
F
OR
CE
B
AS
E
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
M
AR
IA
N
AS
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
1 2 3 4 5
D
C
B
A
1 2 3 4 5
D
C
B
A
BZ ZKS AAY
SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON FULL SIZE ANSI D (22" x 34") SHEET.
AS SHOWN
JEG NO. FDWD7921
1342285
C
FIRE PROTECTION
FO
R
OF
FI
CI
AL
U
SE
O
NL
Y (F
OU
O)
T
T
A
EAC STOR
OPS OFFICE
EAC VAULT
GENERATOR
ROOM
MECHANICAL
ELEC
136 COMM
SECURITY
ENTRY
VESTIBULE
MEN
WOMEN
ENTRAP
FLIGHT
PLANNING
SORTS
CP SUPER
CP OIC
RADIO EQUIP
EAC TR
CAT
TSWA/
OFFICE
SVTC SUITE
CORR.
CORR.
CORRIDOR
EOC
EOC FLEX
MOS/ CBRNE
BREAK
UPS
JAN
TRAINING
OFFICE
CAT STOR
EOC STOR
BREAK
WEATHER
ENCLOSURE
WEATHER
ENCLOSURE
TOILET
EAC
TRAINING
TRANSFORMER
ENCLOSURE
MECHANICAL
YARD
WEATHER
ENCLOSURE
A-411
A-411
A-451
A-451
A-461
A-461
A-461
9A
5A
4A
136A
7A
138A
112A
111A 10 6A
102A
124A
125A
110A 109A
133A
118A
0A
131A
9A
8A
7A
143A
122A
120A
7B
7A
7A
8A
A-401
A-402
A-401
A-402
A-402
EAC
CONTROLLERS
A-402
A-401
110B
(1 9'
5"
(4 1 '
3 / 8"
(3 6 '
5/ 8"
(1 6 '
(1
9"
B
1 3
C
D
E
(45' - 8 7/8")
13940
(17' - 1 3/8")
(33' - 6 3/4")
10230
(2 9'
3/ 8"
(4 4 '
1/ 8"
(1 1 '
3 / 8"
132A
(6' - 11")
RO
(6' - 11")
RO
(1' - 9 1/8")
(1
9"
(1 9 '
9"
(1 1 '
5"
J1
C1
(15' - 5")
WEATHER
ENCLOSURE
147A
B3.A
B3.A
F3
A6 F3F3
(1
0"
143B
101A
126A
121A
(99' - 11")
30455
123A
2%
SL
O
PE
2%
SL
O
PE
(47' - 5 7/8")
14475
(52' - 5 1/8")
15980
146A
100A
(1' - 9 1/8")
(1' - 7 5/8")
101B
101C
140A 141A
(1 8'
3/ 4"
(1 0 '
1/ 2"
(1
9"
(1' - 9")
(1' - 9")
(3
1/
8 "
(7
5"
(8
4"
(1 1 '
8"
A-201
A-201
A-202
A-202
A-301
A-301
A-301
A-301
A-311
139B139C
A-312
(1' - 4 1/8")
(3' - 4 3/4")
(1' - 4 1/8")
(1' - 4 1/8")
410 (2' - 0 7/8")
A-501
R
EG
IS
TERED ARCH
IT
EC
T
S
T A T E O F T EXA
S
C H
R I S
TOP HER M .
S U
R L
E S
2 3 6 3 8
PLAN
NORTH
JACOBS/BURNS & MCDONNELL, A JOINT VENTURE
155 NORTH LAKE AVENUE
PASADENA, CA 91101 USA
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE
AP
R
IN
ST
AL
LA
TI
ON
C
ON
TR
OL
C
EN
TE
R
FY
M
CA
F
PR
OJ
EC
T P-
0/A
JJ
Y1
JR
M
- A
ND
ER
SE
N
AI
R
FO
RC
E
BA
SE
GU
AM
, M
AR
IA
NA
IS
LA
ND
S
NA
VF
AC
M
AR
IA
NA
S
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
JR
M-
AN
DE
RS
EN
A
IR
F
OR
CE
B
AS
E
N
AV
AL
F
AC
IL
IT
IE
S E
N G
IN
EE
R
IN
G C
O M
M
AN
D
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
M
AR
IA
N
AS
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
SY
M
D
ES
C R
IP
TI
O N
D
AT
E A
PP
R
16 FEB 2017
1 2 3 4 5
D
C
B
A
1 2 3 4 5
D
C
B
A
SITE KEY PLAN
SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON FULL SIZE ANSI D (22" x 34") SHEET.
FO
R
OF
FI
CI
AL
U
SE
O
NL
Y (F
OU
O)
AS SHOWN
JEG NO. FDWD7921
1342285
C
OVERALL
FIRE PROTECTION
N
N62742-10-D-0007
2/
/2
9:
:4
AM
A-100
O
VE
R
AL
L
FL
O O
R P
LA
N
CMS BCG GFPR
17195954
KEYNOTES
102 305mm (12") CAST-IN-PLACE CONCRETE WALL, REFER
STRUCTURAL
104 CAST-IN-PLACE CONCRETE WEATHER ENCLOSURE,
REFER A-461
105 455mm (1'-6") RAISED ACCESS FLOORING; REFER A-541
135 ALIGN WALLS
136 FURNITURE LAYOUT, REFER INTERIORS
145 PLUMBING EQUIPMENT, REFER A-411 AND REFER
PLUMBING
1:100
2 8.4m4
1 : 100 1OVERALL FLOOR PLAN
GENERAL NOTES - OVERALL PLAN
A LEVEL 01 DATUM OF 0mm (0'-0") IS A RELATIVE ELEVATION;
ACTUAL FINISH FLOOR ELEVATION IS 175 METERS; REFER
CIVIL
B REFERENCE A-401 AND A-402 FOR ENLARGED PARTIAL
FLOOR PLANS
C REFERENCE G-005 LIFE SAFETY PLANS FOR FIRE RATED
BARRIERS
D REFER TO STRUCTURAL FOR CAST IN PLACE CONCRETE
DETAILS
E ROOM NUMBERS 113-116 NOT USED
F DOWNSPOUTS FOR BASE BID SHOWN; REFER TO A-201A ,
A-202A, AND 10/A-501 FOR OPTIONAL LAYOUTS
S
TA T E O F T EXA
S
2 3 6 3 8
B
EN
BO Z HO
U
PROFESS I ONAL ENG
I N
EE
R
CE
RT
I I CATE
G UA M
No. 1884
(Structural)
EXP. 4/30/2017
F
1WALL ELEVATION ALONG GRID LINE "A"
BO Z HO
U
PROFESS I ONAL ENG
I N
EE
R
CE
RT
I I CATE
G UA M
No. 1884
(Structural)
EXP. 4/30/2017
F
1WALL REINF ALONG GRID "A"
2PARTIAL WALL ELEV - REINF @ VENT OPNG'S 3ENTRY WEATHER ENCLOSURE - SIDE WALL REINF ELEV
BO Z HO
U
PROFESS I ONAL ENG
I N
EE
R
CE
RT
I I CATE
G UA M
No. 1884
(Structural)
EXP. 4/30/2017
F
1WEATHER ENCLOSURE WALL REINF
2SECTION
BO Z HO
U
PROFESS I ONAL ENG
I N
EE
R
CE
RT
I I CATE
G UA M
No. 1884
(Structural)
EXP. 4/30/2017
1BUILDING SECTION A
BO Z HO
U
PROFESS I ONAL ENG
I N
EE
R
CE
RT
I I CATE
G UA M
No. 1884
(Structural)
EXP. 4/30/2017
1BUILDING SECTION B
LEVEL 01
0(0'-0")
T.O. ENTRY
4255(13'-11 1/2")T.O. ENCLOSURE
3655 (12'-0")
1 32
T.O. LOWER ROOF
5625(18'-5 1/2")
A-461
(1
0"
(3
7/
8"
(1 4'
-1
3/ 8"
LVR-9A
(2' - 5 7/8")
RO
(1
1/
2"
R O
(1 2'
-9
LVR-5A
A-301
A-301
A-312
T.O. PARAPET
9595(31'-6")
(1
3/
8"
(1 1'
-0 1/
8"
(3' - 4 3/4")
(1' - 4 1/8")
(4' - 3 1/8")
A
LEVEL 01
0(0'-0")
T.O. ENCLOSURE
3655(12'-0")
B C D E
T.O. LOWER ROOF
5625(18'-5 1/2")
A-461
A-461
(1 1'
-1
7/ 8"
(1 0'
-0 7/
8"
A-451
LVR-4A
132 104
LVR-8A
(3
7/
8"
(1 4'
-1
1/ 2"
TYP
(8' - 6 3/8")
RO
(5
7/
8"
(7
7"
R O
(2' - 0")
(1
1/
2"
(1 2'
-9
A-301
A-301
T.O. PARAPET
9595(31'-6")
R
EG
IS
TERED ARCH
IT
EC
T
S
T A T E O F T EXA
S
C H
R I S
TOP HER M .
S U
R L
E S
2 3 6 3 8
JACOBS/BURNS & MCDONNELL, A JOINT VENTURE
155 NORTH LAKE AVENUE
PASADENA, CA 91101 USA
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE
AP
R
IN
ST
AL
LA
TI
ON
C
ON
TR
OL
C
EN
TE
R
FY
M
CA
F
PR
OJ
EC
T P-
0/A
JJ
Y1
JR
M
- A
ND
ER
SE
N
AI
R
FO
RC
E
BA
SE
GU
AM
, M
AR
IA
NA
IS
LA
ND
S
NA
VF
AC
M
AR
IA
NA
S
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
JR
M-
AN
DE
RS
EN
A
IR
F
OR
CE
B
AS
E
N
AV
AL
F
AC
IL
IT
IE
S E
N G
IN
EE
R
IN
G C
O M
M
AN
D
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
M
AR
IA
N
AS
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
SY
M
D
ES
C R
IP
TI
O N
D
AT
E A
PP
R
16 FEB 2017
1 2 3 4 5
D
C
B
A
1 2 3 4 5
D
C
B
A
SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON FULL SIZE ANSI D (22" x 34") SHEET.
FO
R
OF
FI
CI
AL
U
SE
O
NL
Y (F
OU
O)
AS SHOWN
JEG NO. FDWD7921
1342285
C
FIRE PROTECTION
N62742-10-D-0007
2/
/2
9:
:0
AM
A-202
EX
TE
R
IO
R E
LE
VA
TI
O
N S
- B
AS
E
BI
D
Designer Author Checker
17195960
GENERAL NOTES - ELEVATIONS
A REFER TO A-610 FOR DOOR TYPES
B REFER TO A-641 FOR LOUVER TYPES
C REFER TO I-602 FOR EXTERIOR AND INTERIOR FINISH
SCHEDULE
D PROVIDE SILICONE BASED ELASTOMERIC COATING OVER
ALL EXTERIOR CONCRETE SURFACES (REFER TO I-602)
E ALL EXTERIOR DOORS TO BE HOT-DIPPED GALVANIZED AND
PAINTED. (REFER TO I-602)
F REFER TO A-551 FOR EXTERIOR FORMWORK ELEVATION
DETAILS
KEYNOTES
104 CAST-IN-PLACE CONCRETE WEATHER ENCLOSURE, REFER
A-461 107 BUILT IN CONCRETE GUTTER WITH 150mm (6") DIA PVC
DOWNSPOUT INTEGRATED INTO CONCRETE PILASTER;
1/A-531A
109 MASS NOTIFICATION DEVICE, REFER FIRE PROTECTION
115 155mm x 305mm (6" x 12") SCUPPER (BEYOND) 116 155mm x 305mm (6" x 12") OVERFLOW SCUPPER 117 50mm x 150mm (2" x 6") VENTILATION OPENING CENTERED
ON CONCRETE PLIASTER
132 LIGHT FIXTURE, REFER ELECTRICAL (TYP)
203 50mm (2") RECESSED CONCRETE REVEAL
226 ALL ANTENNA TO BE WALL MOUNTED AND EXTEND PAST
CONCRETE GUTTER, ATTACHED WITH GALVANIZED METAL
FRAMING; REFER TO BASE STANDARDS FOR TYPES AND
LOCATION
245 GFRC ACCESS PANEL DOOR
311 CLEAN OUT CAST IN TO PILASTER, REFER PLUMBING
317 FINISH GRADE, REFER CIVIL
1:100
2 8.4m4
1 : 100 1
EXTERIOR ELEVATION -
WEST
1 : 100 2
EXTERIOR ELEVATION -
NORTH
S
TA T E O F T EXA2 3 6 3 8
B21004 NEW
LOCATION
LEVEL 01
0(0'-0")
T.O. ENTRY
4255(13'-11 1/2")
T.O. CONC ROOF RIDGE
14415(47'-3 1/2")
A-301A
A-301A
T.O. ENCLOSURE
3655 (12'-0")
1 32
107 TYP
A-461
T.O. CONC ROOF EAVE
10605(34'-9 1/2")
(1
5/
8"
(5 3/
4"
(1
3/
4"
R O
,T
YP
(1 3'
-2
(3
7/
8"
(1 4'
-1
3/ 8"
1: 4
1: 4
SLOPE
SLOPE
LVR-9A
(3' - 7 1/4")
(11")
(20' - 7 1/2")
(2' - 5 7/8")
RO
(22' - 5 1/4")
(2' - 5 7/8")
(2
7/
8"
(2 8'
-0
144A
A-312A
T.O. LOWER ROOF
5625(18'-5 1/2")245
TYP
(1
1/
2"
R O
(1 2'
-9
LVR-5A
LVR-25C LVR-26C LVR-27C LVR-28C LVR-29C
LVR-30C LVR-31C
LVR-32C LVR-33C LVR-34C LVR-35C LVR-36C226
(1' - 8 1/8")
(2' - 5 3/4")
(2' - 5 1/2")
TYP
(5' - 0 3/8")
RO, TYP
(1' - 8 1/8")
(11")
(3' - 7 1/2")
A
LEVEL 01
0(0'-0")
T.O. CONC ROOF RIDGE
14415(47'-3 1/2")
A-301A
A-301A
A-461
A-461
T.O. ENCLOSURE
3655(12'-0")
(1 1'
-1
7/ 8"
(1 0'
-0 7/
8"
B C D E
A-451
LVR-4A
T.O. CONC ROOF EAVE
10605(34'-9 1/2")
1: 41: 4
SLOPESLOPE
LVR-8A
(1
5/
8"
(1 4'
-8 3/
8"
(3
7/
8"
(1 4'
-1
1/ 2"
T.O. LOWER ROOF
5625(18'-5 1/2")
311 TYP
(3' - 1 3/8") 950 (11")
(3' - 11 1/4")
(8' - 6 3/8")
RO
(5
7/
8"
(7
7"
R O
(2' - 0")
(4' - 0 1/4")
(11")
(3' - 0 5/8")
(1
1/
2"
(1 2'
-9
R
EG
I S
TERED ARCH
IT
EC
T
S
T A T E O F T EXA
S
C H
R I S
TOP HER M .
S U
R L
E S
2 3 6 3 8
JACOBS/BURNS & MCDONNELL, A JOINT VENTURE
155 NORTH LAKE AVENUE
PASADENA, CA 91101 USA
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE
AP
R
IN
ST
AL
LA
TI
ON
C
ON
TR
OL
C
EN
TE
R
FY
M
CA
F
PR
OJ
EC
T P-
0/A
JJ
Y1
JR
M
- A
ND
ER
SE
N
AI
R
FO
RC
E
BA
SE
GU
AM
, M
AR
IA
NA
IS
LA
ND
S
NA
VF
AC
M
AR
IA
NA
S
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
JR
M-
AN
DE
RS
EN
A
IR
F
OR
CE
B
AS
E
N
AV
AL
F
AC
IL
IT
IE
S E
N G
IN
EE
R
IN
G C
O M
M
AN
D
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
M
AR
IA
N
AS
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
SY
M
D
ES
C R
IP
TI
O N
D
AT
E A
PP
R
16 FEB 2017
1 2 3 4 5
D
C
B
A
1 2 3 4 5
D
C
B
A
SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON FULL SIZE ANSI D (22" x 34") SHEET.
FO
R
OF
FI
CI
AL
U
SE
O
NL
Y (F
OU
O)
AS SHOWN
JEG NO. FDWD7921
1342285
C
FIRE PROTECTION
N62742-10-D-0007
2/
/2
9:
:4
AM
A-202A
EX
TE
R
IO
R E
LE
VA
TI
O
N S
- O
PT
IO
N
S 1-
CMS BCG GFPR
17195961
1 : 100 1
EXTERIOR ELEVATION -
WEST
1 : 100 2
EXTERIOR ELEVATION -
NORTH 0
1:100 2 8.4m4
KEYNOTES
104 CAST-IN-PLACE CONCRETE WEATHER ENCLOSURE, REFER
A-461 107 BUILT IN CONCRETE GUTTER WITH 150mm (6") DIA PVC
DOWNSPOUT INTEGRATED INTO CONCRETE PILASTER;
1/A-531A
109 MASS NOTIFICATION DEVICE, REFER FIRE PROTECTION
132 LIGHT FIXTURE, REFER ELECTRICAL (TYP)
203 50mm (2") RECESSED CONCRETE REVEAL
226 ALL ANTENNA TO BE WALL MOUNTED AND EXTEND PAST
CONCRETE GUTTER, ATTACHED WITH GALVANIZED METAL
FRAMING; REFER TO BASE STANDARDS FOR TYPES AND
LOCATION
245 GFRC ACCESS PANEL DOOR
311 CLEAN OUT CAST IN TO PILASTER, REFER PLUMBING
317 FINISH GRADE, REFER CIVIL
426 CONCRETE ROOFING TILE ON 40 MIL SELF-ADHERING
MEMBRANE UNDERLAYMENT ON ASPHALT PRIMER AS
SPECIFIED
GENERAL NOTES - ELEVATIONS
A OPTION 1: CONCRETE UPPER ROOF WITH SILICONE
ELASTOMERIC ROOF COATING, REFER A-142 SIM
B OPTION 2: CONCRETE UPPER ROOF WITH PREFINISHED
METAL SIMULATED ROOF TILE, REFER A-142 AND DETAILS
1-4/A-531
C OPTION 3: CONCRETE UPPER ROOF WITH CONCRETE ROOF
TILES, REFER A-142 AND DETAILS 1-4/A-531A
D REFER TO A-610 FOR DOOR TYPES
E REFER TO A-641 FOR LOUVER TYPES
F REFER TO I-602 FOR EXTERIOR AND INTERIOR FINISH
SCHEDULE
G PROVIDE SILICONE BASED ELASTOMERIC COATING OVER
ALL EXTERIOR CONCRETE SURFACES (REFER TO I-602)
H ALL EXTERIOR DOORS TO BE HOT-DIPPED GALVANIZED AND
PAINTED. (REFER TO I-602)
J REFER TO A-551 FOR EXTERIOR FORMWORK ELEVATION
DETAILS
TA T E O F T EXA2 3 6 3 8
A
B
1 3
C
D
E
1:
1:
SL
O
PE
SL
O
PE
(19' - 0 1/2")
T.O. RIDGE
(18' - 5 1/2")
(31' - 6")
T.O. PARAPET
BASE BID
(3' - 6 3/4")
(1' - 0 1/4")
(8 1/2")
(1' - 0") 305 (43' - 2 1/4")
13165
(1' - 0")
(43' - 1 7/8")
13155
(1' - 0") 305 (5' - 3 3/8")
(3' - 6 3/4")
(1' - 0 1/4")
(8 1/2")
(1' - 0")
(43' - 10 1/8")
13365
(1' - 0")
(43' - 10")
13360 (1' - 0")
(8 1/2")
(1' - 0 1/4")
(2' - 2 3/4")
112 116 116
116 112
118118
128128
116116
A
B
1 3
C
D
E
(45' - 8 7/8")
13940
(17' - 1 3/8")
(33' - 6 3/4")
10230
(1 9'
-5
(4 1 '
-1
3 / 8"
(3 6 '
-4 5/
8"
(1 6 '
-1 0"
A-531A
TYP
A-201
A-201
A-202
A-202 1 1
A-301
A-301
A-301
A-301
A-311
A-312
(31' - 6")
T.O. PARAPET
BASE BID
R
EG
IS
TERED ARCH
IT
EC
T
S
T A T E O F T EXA
S
C H
R I S
TOP HER M .
S U
R L
E S
2 3 6 3 8
PLAN
NORTH
JACOBS/BURNS & MCDONNELL, A JOINT VENTURE
155 NORTH LAKE AVENUE
PASADENA, CA 91101 USA
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE
AP
R
IN
ST
AL
LA
TI
ON
C
ON
TR
OL
C
EN
TE
R
FY
M
CA
F
PR
OJ
EC
T P-
0/A
JJ
Y1
JR
M
- A
ND
ER
SE
N
AI
R
FO
RC
E
BA
SE
GU
AM
, M
AR
IA
NA
IS
LA
ND
S
NA
VF
AC
M
AR
IA
NA
S
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
JR
M-
AN
DE
RS
EN
A
IR
F
OR
CE
B
AS
E
N
AV
AL
F
AC
IL
IT
IE
S E
N G
IN
EE
R
IN
G C
O M
M
AN
D
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
M
AR
IA
N
AS
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
SY
M
D
ES
C R
IP
TI
O N
D
AT
E A
PP
R
16 FEB 2017
1 2 3 4 5
D
C
B
A
1 2 3 4 5
D
C
B
A
SITE KEY PLAN
SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON FULL SIZE ANSI D (22" x 34") SHEET.
FO
R
OF
FI
CI
AL
U
SE
O
NL
Y (F
OU
O)
AS SHOWN
JEG NO. FDWD7921
1342285
C
OVERALL
FIRE PROTECTION
N
N62742-10-D-0007
2/
/2
9:
:1
AM
A-141
O
VE
R
AL
L R
O O
F
PL
AN
BA
SE
B
ID
CMS BCG GFPR
17195956
KEYNOTES
112 155mm x 305mm (6" x 12") SCUPPER THROUGH WALL; INTO
150mm (6") DIA PVC DOWNSPOUT INTEGRATED INTO
CONCRETE PILASTER
116 155mm x 305mm (6" x 12") OVERFLOW SCUPPER 118 LEAN CONCRETE TOPPING ON 1065mm MAIN ROOF, SLOPED 1:100; REFER A-141
128 SILICONE BASED ELASTOMERIC COATING OVER
CONCRETE ROOF DECK (P-5) (TYP.)
277 LINE OF WALL (BELOW)
339 CONCRETE TRUSS ASSEMBLY IN OPTIONS 1-3 ONLY;
REFER STRUCTURAL
354 BUILT IN CONCRETE GUTTER WITH 150mm(6") DIA PVC
DOWNSPOUT INTO CONCRETE PILASTER
426 CONCRETE ROOFING TILE ON 40 MIL SELF-ADHERING
MEMBRANE UNDERLAYMENT ON ASPHALT PRIMER AS
SPECIFIED
880 ROOF VENT, REFER 4/A-541 (TYP)
1:100
2 8.4m4
GENERAL NOTES - ROOF PLAN
A PROVIDE SILICONE BASED ELASTOMERIC COATING OVER
ALL EXTERIOR CONCRETE SURFACES
B GALVANIZED METAL ANGLE TRIPOD ANTENNAS AND
TRIPOD SUPPORTS ARE GOVERNMENT
FURNISHED/GOVERNMENT INSTALLED. CONTRACTOR
SHALL INSTALL SLEEVE PENETRATIONS AT LOCATIONS
COORDINATED WITH THE CONTRACTING OFFICER
1 : 200 2
OVERALL ROOF PLAN -
BELOW FINS
1 : 100 1
OVERALL ROOF PLAN -
ABOVE FINS
A-201A
A-201A
A-202A
A-202A
A
A-301A
A-301A
A-301A
A-301A
B
1 3
C
D
E
1: 4 1: 4 1:
SLOPESLOPE
SL
O
PE
SL
O
PE
1:
(45' - 8 7/8")
13940
(17' - 1 3/8")
(33' - 6 3/4")
10230
(1 9'
-5
(4 1 '
-1
3 / 8"
(3 6 '
-4 5/
8"
(1 6 '
-1 0"
14412 (47'-3 1/2")
T.O. RIDGE
T.O. ROOF EAVE
(34'-9 1/2")
A-531A
TYP
A-312A
106045
(6' - 1 3/8")
(4' - 9 1/2")
(6' - 1 3/8")
(4' - 9 1/2")
(2
0"
(T
YP
(2
0"
(T
YP
(2
0"
(T
YP
(2
0"
(T
YP
(1
1/
8 "
(1
1/
8 "
R
EG
I S
TERED ARCH
IT
EC
T
S
T A T E O F T EXA
S
C H
R I S
TOP HER M .
S U
R L
E S
2 3 6 3 8
PLAN
NORTH
JACOBS/BURNS & MCDONNELL, A JOINT VENTURE
155 NORTH LAKE AVENUE
PASADENA, CA 91101 USA
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE
AP
R
IN
ST
AL
LA
TI
ON
C
ON
TR
OL
C
EN
TE
R
FY
M
CA
F
PR
OJ
EC
T P-
0/A
JJ
Y1
JR
M
- A
ND
ER
SE
N
AI
R
FO
RC
E
BA
SE
GU
AM
, M
AR
IA
NA
IS
LA
ND
S
NA
VF
AC
M
AR
IA
NA
S
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
JR
M-
AN
DE
RS
EN
A
IR
F
OR
CE
B
AS
E
N
AV
AL
F
AC
IL
IT
IE
S E
N G
IN
EE
R
IN
G C
O M
M
AN
D
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
M
AR
IA
N
AS
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
SY
M
D
ES
C R
IP
TI
O N
D
AT
E A
PP
R
16 FEB 2017
1 2 3 4 5
D
C
B
A
1 2 3 4 5
D
C
B
A
SITE KEY PLAN
SCALE(S) AS NOTED ON THIS SHEET ARE BASED ON FULL SIZE ANSI D (22" x 34") SHEET.
FO
R
OF
FI
CI
AL
U
SE
O
NL
Y (F
OU
O)
AS SHOWN
JEG NO. FDWD7921
1342285
C
OVERALL
FIRE PROTECTION
N
N62742-10-D-0007
2/
/2
9:
:4
AM
A-142
O
VE
R
AL
L R
O O
F
PL
AN
O
PT
IO
N
S 1-
CMS BCG GFPR
17195957
1 : 100 1OVERALL ROOF PLAN
GENERAL NOTES - ROOF PLAN
A OPTION 1: CONCRETE UPPER ROOF WITH SILICONE
ELASTOMERIC ROOF COATING, REFER A-142 SIM
B OPTION 2: CONCRETE UPPER ROOF WITH PREFINISHED
METAL SIMULATED ROOF TILE, REFER A-142 AND DETAILS
1-4/A-531
C OPTION 3: CONCRETE UPPER ROOF WITH CONCRETE
ROOF TILES, REFER A-142 AND DETAILS 1-4/A-531A
D PROVIDE SILICONE BASED ELASTOMERIC COATING OVER
ALL EXPOSED CONCRETE SURFACES
E GALVANIZED METAL ANGLE TRIPOD ANTENNAS AND
TRIPOD SUPPORTS ARE GOVERNMENT
FURNISHED/GOVERNMENT INSTALLED. CONTRACTOR
SHALL INSTALL SLEEVE PENETRATIONS AT LOCATIONS
COORDINATED WITH THE CONTRACTING OFFICER
F CONCRETE ROOF TILE SYSTEM TO MATCH BASE
ARCHITECTURAL COMPATIBILITY DESIGN STANDARDS
AND MEET ASCE 7-10 WIND LOAD REQUIREMENTS FOR
COMPONENTS AND CLADDING 235 MPH EXPOSURE
CATEGORY C
KEYNOTES
277 LINE OF WALL (BELOW)
354 BUILT IN CONCRETE GUTTER WITH 150mm(6") DIA PVC
DOWNSPOUT INTO CONCRETE PILASTER
426 CONCRETE ROOFING TILE ON 40 MIL…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .