T.O. 1B-2A-37
30 NOVEMBER 2008
TECHNICAL MANUAL
USAF CALIBRATION AND
MEASUREMENT SUMMARY
AND
WORK UNIT CODE MANUAL
FOR
B-2 SPIRIT
WEAPON SYSTEM
This publication replaces T.O. 1B-2A-37 dated 30 May 2008.
WARNING - This document contains technical data whose export is restricted by the Arms Export Control Act (Title 22, U.S.C., Sec 2751 et. seq.) or the Export Administration Act of 1979, as amended, Title 50, U.S.C., App. 2401 et. seq. Violations of these export laws are subject to severe criminal penalties.
Disseminate in accordance with provisions of DoD Directive 5230.25.
DISTRIBUTION D - Distribution authorized to Department of Defense and U.S. DoD contractors for official use or for administrative or operational purposes only, 30 November 2007. Refer other requests for this document to 562 CBSG/GBHA, 813 Irving-Wick Dr W, Heath, OH 43056-1199.
Destruction Notice - For unclassified, limited documents, destroy by any method that will prevent disclosure of the contents or reconstruction of the document.
Published under Authority of the Secretary of the Air Force
A USAF
INSERT LATEST CHANGED PAGES. DESTROY SUPERSEDED PAGES.
NOTE: The portion of the text and illustrations affected by the changes is indicated by a vertical line in the outer margins of the page.
Date of issue for original and changed pages are:
Original .......................... 0 .................. 30 November 2008
TOTAL NUMBER OF PAGES IN THIS PUBLICATION IS 12, CONSISTING OF THE FOLLOWING:
Page * Change Page * Change Page * Change No. No. No. No. No. No.
Title A i ii Blank 1-1 - 1-6 2-1 2-2 Blank
Zero in this column indicates an original page
LIST OF EFFECTIVE PAGES
i/(ii Blank)
TABLE OF CONTENTS
Chapter Page
1 INTRODUCTION .................................................................................................................. 1-1
1.1 PURPOSE ............................................................................................................... 1-1
1.2 SCOPE .................................................................................................................. 1-1
1.3 RELATED DOCUMENTS .................................................................................... 1-1
1.4 SUPPORT CONCEPT ........................................................................................... 1-2
1.5 DEFINITIONS ....................................................................................................... 1-3
1.6 EXPLANATION OF WORKLOAD CALIBRATION
REQUIREMENTS LISTING ................................................................................ 1-3
1.7 ABBREVIATIONS ................................................................................................ 1-5
2 B-2 SUPPORT EQUIPMENT (SE) .......................................................................................2-1
2.1 SUPPORT EQUIPMENT CALIBRATION REQUIREMENTS .........................2-1
1-1
CHAPTER 1
INTRODUCTION
1.1 PURPOSE:
1.1.1 Define Requirements. To define calibration and measurement requirements for the B-2 Weapon System and associated support equipment (SE).
1.1.2 Define Policies. To define policies involving calibration support of the B-2 Weapon System.
1.1.3 Identify Calibration Authority. To identify calibration authority in terms of what and when SE requires calibration and the organization responsible for support.
1.1.4 Determining Workload. To assist in determining calibration workload imposed on operating organizations, depot, and supporting Precision Measurement Equipment Laboratories (PMELs).
1.2 SCOPE:
1.2.1 Level of Support. This technical order (T.O.) covers calibration and measurement requirements at all levels of support for the B-2 Weapon System. This includes organizational (O), intermediate (I), technical repair centers (TRC), test sites, training sites, and depot (D) activities.
1.2.2 Jet Engine SE. F118-GE-100 Engine SE are identified in Jet Engine Systems Calibration and Measurement Summary, T.O. 2J-1-105.
1.2.3 Two Chapters. This T.O. consists of two chapters.
1.2.3.1 Chapter 1, INTRODUCTION, contains the purpose, scope, related documents, support concept, definitions, an explanation of workload tables, and other pertinent information.
1.2.3.2 Chapter 2, B-2 SUPPORT EQUIPMENT, identifies method of viewing B-2 SE calibration requirements.
SE used at all levels of B-2 maintenance and calibration are identified.
1.3 RELATED DOCUMENTS:
1.3.1 This T.O. will be used with the following documents:
a. AFI 21-113, Air Force Metrology and Calibration (AFMETCAL) Program.
b. AFI 21-101, Aircraft and Equipment Maintenance Management.
c. AFMAN 23-110, USAF Supply Manual.
d. T.O. 00-5-17, USAF Computer Program Identification Numbering (CPIN) System.
e. T.O. 00-20-2, Maintenance Data Documentation.
f. T.O. 00-20-14, Air Force Metrology and Calibration Program.
g. T.O. 00-25-06-2-1, Intermediate Maintenance Instructions Work Unit Code Manual - 412A Survival/Life Support System Equipment.
h. T.O. 00-25-06-2-2, Depot, Intermediate, and Organizational Maintenance - Work Unit Code Manual - Support Equipment.
1-2
i. T.O. 2J-1-105, USAF Calibration and Measurement Summary and Work Unit Code Manual for Jet Engine Systems.
j. T.O. 33-1-27, Logistic Support of Test, Measurement, and Diagnostic Equipment.
k. T.O. 33K Series Calibration Procedures.
l. T.O. 33K-1-100-1, Calibration Procedure for Maintenance Data Collection Codes and Calibration Measurement Summaries.
m. T.O. 33K-1-100-2, TMDE Calibration Notes, Calibration Interval, Technical Order and Work Unit Code Reference Guide.
n. T.O. 51-1-06-1, Depot, Intermediate, and Organizational Maintenance - Work Unit Code Manual - Automatic Test Equipment
1.4 SUPPORT CONCEPT:
1.4.1 Calibration and Maintenance.
1.4.1.1 Calibration and maintenance of B-2 Weapon System SE will be accomplished at the lowest practical echelon possible based on concept of operation and equipment authorizations. The organization responsible for support is included in calibration requirements listings addressed in Chapter 2.
1.4.1.2 T.O. 00-20-14 holds the Methods and Procedures for the management of the Air Force Metrology and Calibration (AFMETCAL) Program. This program is established and directed by AFI 21-113. Calibration authority order of precedence is as follows:
1 - T.O. 1B-2A-37 and addendum T.O. 1B-2A-37-1 2 - Sub-system Calibration and Measurement Summaries (CMSs) 3 - T.O. 33K-1-100-2 4 - T.O. 33K-1-100-1 Sec 3 5 - Other official DoD calibration procedures 6 - Equipment maintenance T.O.
7 - Commercial publications or commercial data
The applicable calibration procedure and interval will be identified in the Cal TO and Cal Interval fields of calibration requirements listing. When a calibration interval is not listed in the above documents and the item requires calibration, the interval shall not be greater than 12 months.
1.4.1.3 Requests concerning calibration responsibility determinations for B-2 SE (Chapter 2) should be sent via AFTO Form 45 IAW T.O. 00-20-14, Section 5, annotated as "B-2" in the “Weapon Sys(s) or End Item Supported” block. Direct inquiries may be made via Defense Switched Network (DSN) 366-5065 or Commercial 740-788- 5065 to 562 CBSG/GBNA.
1.4.1.4 Certain calibration range and accuracy requirements of B-2 SE will be dictated by system or subsystem needs in lieu of manufacturer's specifications. 33K series calibration procedures are prepared and maintained by 562 CBSG/GBHA. Any change or correction to these procedures will be via AFTO Form 22 action.
1.4.1.5 Torque indicating devices are considered TMDE and will be calibrated by the PMEL. Torque indicating devices not listed in this T.O. will be calibrated IAW T.O. 33K-1-100-1/-2.
1.4.1.6 Field Training Detachment (FTD) equipment calibration requirements are identified in calibration requirements listings in this T.O. or T.O. 33K-1-100-2. See T.O. 00-20-14 for additional information concerning training equipment calibration requirements.
1.4.1.7 See T.O. 00-20-14 for definition and guidance on calibration authority defined as Contract and Commercial calibration of TMDE.
1-3
1.4.1.8 Calibration support for B-2 TMDE was developed using a minimum 3:1 TUR between system operational tolerances and TMDE uncertainties. TURs less than minimum requirements are documented in applicable calibration procedures.
1.4.2 Equipment.
1.4.2.1 Equipment required by the PMEL to support the B-2 Weapon System is listed in Allowance Source Code
(ASC) 734.
1.4.2.2 The user will furnish all special cables, adapters, hardware, and software needed to interface Core Standards to Portable Automatic Test Equipment Calibrator (PATEC).
1.4.2.3 Refer to N65 in AFCAV for a listing of PMELs supporting photometers with the PCS-300 Photometric Calibration System. Refer to N42 for Spectral Radiance Head or Light Source calibration capability.
1.4.3 Facilities.
1.4.3.1 PMEL facility requirements are identified in Section 8 of T.O. 00-20-14.
1.4.3.2 When operating a PMEL outside the environmental limits of T.O. 00-20-14, Section 8, consult equipment manufacturer's specifications for any necessary correction factors or environmental restrictions.
1.4.4 Quality Assurance. The PMEL quality assurance program must ensure laboratory production meets established safety and accuracy requirements with traceability to national standards. Quality assurance shall be in accordance with T.O. 00-20-14.
1.5 DEFINITIONS:
1.5.1 The following definitions are in addition to those in T.O. 00-20-14 and T.O. 33K-1-100-1:
a. SERD - Support Equipment Recommendation Data. A contractual data item submitted by the contractor to identify weapon system SE requirements.
b. TUR - Test Uncertainty Ratio. The maximum permitted error of the unit to be measured or calibrated divided by the maximum known error of the measuring or generating device used to perform the measurement.
1.6 EXPLANATION OF WORKLOAD CALIBRATION REQUIREMENTS LISTING:
The following describes the data fields as displayed in Air Force Calibration Authority Viewer (AFCAV) tree view:
a. Part Number - The manufacturer's part, model, or type number.
b. Work Unit Code - Codes listed herein will be used for LANTIRN SE.
c. Noun - Description of item.
1-4
d. Cal Responsibility - Support Responsibility. The organization assigned support responsibility for calibration and maintenance actions. When more than one organization is listed, the first is responsible for calibration, the second for maintenance.
AFPSL The Air Force Primary Standards Laboratory at Heath, Ohio. (See T.O.
33K-1-100-1.)
CONTRACT Commercial calibration not funded by 562 CBSG. (See T.O. 33K-1-100-
1.)
N( ) Reference appropriate note in T.O. 33K-1-100-2.
PMEL The supporting PMEL.
PMEL/CONTRACT The supporting PMEL for calibration, contractor for maintenance.
PMEL/SICL The supporting PMEL except as listed separately.
PMEL/USER The supporting PMEL for calibration, the owning organization for maintenance.
PMEL2A The area Type IIA PMEL.
PMEL 68DEG A PMEL with an authorized 68 degree dimensional calibration area.
REM See the REMARKS field.
SICW See Item Calibrated With. (See T.O. 33K-1-100-1.)
USER The owning organization. (See T.O. 33K-1-100-1.)
USER/CONTRACT The owning organization for calibration, contractor for maintenance.
USER/PMEL The owning organization for calibration, the supporting PMEL for maintenance.
USER/SICL Owning organization except as listed separately.
e. Cal Interval - Calibration Interval. Calibration interval expressed in months unless noted otherwise.
CBU Calibrate Before Use.
ICO Initial Calibration Only. (See T.O. 00-20-14.)
N( ) Use appropriate note instructions in T.O. 33K-1-100-2.
NCR No Calibration Required.
NEC No End item Calibration.
NHA Next Higher Assembly. Calibrate as part of the next higher assembly. Use same
C/I and Calibration T.O. unless noted otherwise.
NPC No Periodic Calibration required. (See T.O. 00-20-14.)
REM See the REMARKS field.
SCW See item Calibrated With. (See T.O. 33K-1-100-1.)
f. Cal TO – Calibration Technical Order. Document used for calibration support.
N( ) Reference appropriate note in T.O. 33K-1-100-2.
NCR No Calibration Required. No CTO required.
NEC No End item Calibration. No CTO required.
NHA Next Higher Assembly. Use same CTO as NHA.
REM See the REMARKS field.
SICW See Item Calibrated With. (See T.O. 33K-1-100-1.)
g. Maint TO - Maintenance Technical Order. Document used for maintenance support. This field is for information purposes only.
h. Auto CTO - See T.O. 33K-1-100-1 for description.
i. Cage code - Manufacturer's commercial, and government entity (CAGE) number.
j. Manuf Code - Manufacturer's five-character code.
k. Change Code - See T.O. 33K-1-100-1 for description.
1-5
l. Change Date - Date of most recent change.
m. Specifications - See T.O. 33K-1-100-1 for description.
n. NSN - National Stock Number. Provided for informational purposes only.
o. LOM - Level of Maintenance. The level(s) of maintenance for which the item is required.
O Organizational I Intermediate D Depot
p. SERD - Support Equipment Recommendation Data number.
q. Remarks - This field is used for listing various information such as special instructions, the next higher assembly, "same as" information, limited calibration specifications, etc.
1.7 ABBREVIATIONS:
ACCY Accuracy ACFT Aircraft ADAPT Adapter AFCAV Air Force Calibration Authority
Viewer AFMETCAL Air Force Metrology and
Calibration AFPSL Air Force Primary Standards
Laboratory AG Arresting Gear AKA Also Known As ALT Alternate AME Alternate Mission Equipment APU Auxiliary Power Unit ASC Allowance Source Code ASSY Assembly ATE Automatic Test Equipment AUTH Authority or Authorized CAGE Commercial and Government
Entity CAL Calibrate or Calibration CBU Calibrate Before Use CFE Contractor Furnished Equipment CHG Change CMAL Controlled Multiple Address
Letter CNX Canceled COLT Common O-Level Tester COM Commercial CPIN Computer Program Identification
Number CTPS Calibration Test Program Set CTO Calibration Technical Order D Depot DCM Deputy Commander for
Maintenance DEG Degree(s) DIFA Digital/Fast Analog DIMS Dimensions
DMM Digital Multimeter DSN Defense Switched Network DWG Drawing EOD Explosive Ordinance Disposal EW Electronic Warfare F Fahrenheit FACTS Flight Avionics Consolidated
Test System FIX Fixture FO Fiber Optic FLT Flight FREQ Frequency FS Full Scale FTD Field Training Detachment GFE Government Furnished
Equipment I Intermediate IAW In Accordance With ICO Initial Calibration Only IEC International Electrotechnical
Commission IM Item Manager IN Inch I/R Installation/Removal IRCM Infrared Counter Measures ISO International Organization for
Standardization ITA Interface Test Adapter LBS Pounds LOM Level of Maintenance LP Local Purchase LTD CAL Limited Calibration MFG Manufacturer MLG Main Landing Gear MSPE Maintenance, Safety, and
Protection Equipment NCR No Calibration Required NDI Non-Destructive Inspection NEC No End-item Calibration
1-6
NHA Next Higher Assembly NLG Nose Landing Gear NPC No Periodic Calibration NSN National Stock Number O Organizational OPT Option or Optional PAMS PMEL Automated Management
System PARA Paragraph PATEC Portable Automatic Test
Equipment Calibrator PCE Portable Calibration Equipment PKG Package PMEL Precision Measurement
Equipment Laboratory PN or P/N Part Number P/O Part of PWR Power RADATS Radar-Radio Automatic Test
Station R/B Replace By REQS Requirements REV Revision RFAD Radio Frequency Analog/Digital S/A Same as SCW See item Calibrated With SE Support Equipment SES Stored Energy System SERD Support Equipment
Recommendation Data SICL See Individual Component
Listing SICW See item Calibrated With SIM Simulator SMS Stores Management System SSA Same Specification As STD Standard SUB Substitute TBA To Be Announced TBD To Be Determined TMDE Test, Measurement, and
Diagnostic Equipment TO Technical Order TPS Test Program Set TRC Technology Repair Center TRU Test Replaceable Unit TS or T/S Test Set, Test Stand, Test
Station, or Test System TUR Test Uncertainty Ratio UUT Unit Under Test WUC Work Unit Code
2-1/(2-2 Blank)
CHAPTER 2
B-2 SUPPORT EQUIPMENT (SE)
2.1 SUPPORT EQUIPMENT CALIBRATION REQUIREMENTS:
2.1.1 This section identifies method of viewing calibration requirements of B-2 SE authorized for all levels of calibration and maintenance support. Calibration requirements listings will be adjusted and revised by 562 CBSG as new equipment and/or changes are identified.
2.1.2 Calibration requirements listings for B-2 SE are viewable using Air Force Calibration Authority Viewer (AFCAV) by selecting source document “B2A”.
File details come from the government source that posted it. Updated .