FA4801-11-R-0001-0003
ADDITIONAL WRITTEN QUESTIONS FROM 20 MAY 11 SITE VISIT
1. Q: How much of outside plant is direct buried and/or in conduit?
A. Seventy-five percent of outside plant is in conduit. The footage is unknown.
2. Q: Do manholes currently have locking lids installed?
A. Keys will be available for manholes that are locked. This is a security issue and should not be given out to the public.
3. Q: During exercises will contractor be required to wear MOPP gear and if so, will Government provide training and equipment?
A. No, contractor will not be required to wear MOPP gear during exercises.
ADDITIONAL EMAIL QUESTION OF IMPORTANCE
1. Q: CLIN/PID Number 7040 asks for a quantity of 50 each, of a "700A Singlemode Fiber Transceiver with Attenuators". This product will cost approximately $6,000 each, adding about $300,000 to our Pricing. Is this quantity correct?
A: Delete PID Number 7040 (700A Singlemode Fiber Transceiver with Attenuators) from the PIRRM.
2. Q: The following PIDs (highlighted) on the PIRRM appear to be duplicates, can you verify?
| 6252 |
| Trenching through and restoration of Soft Surfaces, 18" wide, 40" deep [ 2x2 conduit layout] |
| 1,000 |
| FT |
| 1,000 |
| 1,000 |
| 6253 |
| Trenching through and restoration of Hard Surfaces, 18" wide, 30" deep [ 1x2 conduit layout] |
| 1,000 |
| FT |
| 1,000 |
| 1,000 |
| 6254 |
| Trenching through and restoration of Hard Surfaces, 18" wide, 40" deep [ 2x2 conduit layout] |
| 1,000 |
| FT |
| 1,000 |
| 1,000 |
| 6256 |
| Cutting through Concrete, 24" wide |
| 1,000 |
| FT |
| 1,000 |
| FT |
| 6257 |
| Cutting through and Resurfacing of Rock Bases |
| 1,000 |
| FT |
| 1,000 |
| FT |
| 6263 |
| Trenching through and restoration of Soft Surfaces, 18" wide, 30" deep [ 1x2 conduit layout,trench onlys] |
| 1,000 |
| FT |
| 1,000 |
| FT |
| 6264 |
| Trenching through and restoration of Soft Surfaces, 18" wide, 40" deep [ 2x2 conduit layout,trench only] |
| 1,000 |
| FT |
| 1,000 |
| FT |
| 6265 |
| Trenching through and restoration of Soft Surfaces, 18" wide, 40" deep [ 2x2 conduit layout, trench only] |
| 1,000 |
| FT |
| 1,000 |
| FT |
| 6267 |
| Trenching through and restoration of Hard Surfaces, 6" wide, 30" deep trench only] |
| 1,000 |
| FT |
| 1,000 |
| FT |
| 6268 |
| Trenching through and restoration of Hard Surfaces, 6" wide, 30" deep [trench only] |
| 1,000 |
| FT |
| 1,000 |
| FT |
| 6274 |
| Cutting through Concrete, 24" wide |
| 1,000 |
| FT |
| 1,000 |
| FT |
| 6279 |
| Cutting through and Resurfacing of Rock Bases |
| 1,000 |
| FT |
| 1,000 |
| FT |
| 6402 |
| Directional bore through or under Hard Su, Purchase Schedule 80 conduit under separate SLIN |
| 50 |
| FT |
| 50 |
| FT |
| 6403 |
| Directional bore through or under Hard Surface and Install 4 inch 1-way duct into the bore, Purchase Schedule 80 conduit under separate SLIN |
| 50 |
| FT |
| 50 |
| FT |
| 7135 |
| 10ft ground rod, Ground rod clamp, Ground lug #6 wire w/ set screw,6-10 Screw type terminal ground bus bar, 6-10 Screw type terminal ground bus bar |
| 50 |
| EA |
| 50 |
| EA |
| 7085 |
| 10ft ground rod, Ground rod clamp, Ground lug #6 wire w/ set screw,6-10 Screw type terminal ground bus bar, 6-10 Screw type terminal ground bus bar |
| 50 |
| EA |
| 50 |
| EA |
A. Yes, there are duplicates. The PIRRM (1 Jun 11) has been updated to delete the duplicated PIDs.
Additional Questions for FA4801-11-R-0001 Holloman AFB BTS O&M
1. Q. Reference the PWS and associated Appendices and regarding the equipment maintained by the Contractor, does the contractor have responsibility for the maintenance and repair of any Air Conditioning equipment in telecommunication rooms or switch rooms?
A. No, the contractor is not responsible for maintenance and repair of air conditioning equipment in the telecommunications rooms or switch rooms.
2. Q. Regarding PWS Section 1.3.3.3, based on the contract requirements, is it fair to say that ALL manholes have undergone a PMI during the course of the current contract?
A. No, not all the manholes, hand holes or pullboxes have had PMIs during the course of the current contract.
3. Q. If so, would it be possible to review the maintenance records to assess scheduling priorities for continued PMI? – A. No, not at this time, upon award the contractor will have access to 4 years of data on PMIs. PMIs are based on paragraph of 1.3.3 of the PWS and the contractor can base his PMI schedule on that information.
4. Are there any BRAC Considerations, either losses or gains, projected for Holloman AFB?
A. There are no future plans for Base Realignment and Closure (BRAC) scheduled for Holloman AFB or any other base at this time. The last BRAC was in 2005. Losses and gains are impacted by the missions at Holloman AFB and this is always changing due to AF needs. With our vast airspace, no future closure is anticipated. There is a projected bed down of a new mission for F-16s at Holloman AFB in 2012 but the number of personnel affecting the base is unknown.
5. Q. In light of the recent and current flooding and other natural disasters, are there any unique requirements for continuity of operations? Is there a current disaster plan in place, and if so, would it be possible to review same? – A. Every base has some sort of disaster plan. Holloman AFB, has a local plan – HAFB 10-2, Comprehensive Emergency Management Plan which gives base response information on major accidents including aircraft accidents, environmental spills, fires and other natural disasters. This information is For Official Use Only and not readily available to the public. If the awardee has a “need to know”, the firm may possibly have access to this information.
6. Q. Is Dial-In Capability, in compliance with AFI 33-111 Section G, allowed for the DCO Switch or Remotes at Holloman AFB?
A. Yes, dial-in capability is allowed.
7. A. Regarding PWS Section 5.2.2, are there any spares available, that can be used by the contractor, for the CFE listed in 5.2.2?
A. Yes, however, the Government has limited spares
8. Q. Regarding PWS Section 5.2.2, are any of the 5.2.2 items under warranty or a maintenance agreement from another source?
A. Equipment in 5.2.2 are under warranty using the Voice Switching System (VSS) sustainment plan
9. Q. Regarding PWS Section 5.2.2, are any of the items listed in 5.2.2 out-of-production? – A. Some Key Systems, are in the process of being replaced.
10. Q. Regarding PWS Section 5.2.2, if a System or Component listed in 5.2.2 is no longer in production, and repair/replacement parts are no longer available, what is the Contractor's responsibility? – A. Contractor will identify the equipment and the Government will budget to get equipment replaced
11. Q. Regarding PWS Section 5.2.3, does the Base have a full set of Technical Manuals for the Avaya Equipment?
A. No, the Government does not maintain a full set of technical manuals. Technical manuals are on-line. It is suggested, contractor find all applicable documentation online.
12. Q. PWS Section 5.2.5.2 indicates that there are approximately 375 manholes, what is the quantity of hand holes?
A. There are approximately 128 hand holes.
13. Q. Regarding PWS Section 5.2.3, does the Government provide any test equipment or Cable Testers?
A. No, the Government does not provide equipment. It is the responsibility of the Contractor.
14. Q. Regarding PWS Section 5.2.3, does the Government provide a cable locator?
A. No, the Government does not provide equipment. It is the responsibility of the Contractor.
15. Q. Regarding PWS Section 5.2.3, does the Government provide Backhoes/Trenchers for OSP excavation?
A. No, the Government does not provide equipment. It is the responsibility of the Contractor.
16. Q. Regarding PWS Section 5.2.3, does the Government provide a Manhole Retrieval System?
A. No, the Government does not provide equipment. It is the responsibility of the Contractor.
17. Q. Regarding PWS Section 5.2.3, does the Government provide any computers/work stations? – A. Yes, as stated at the site visit, the Government provides a plotter and four computers for the Contractor’s Government furnished onsite location (Bldg 221). One computer is strictly for the required on-line training.
18. Q. Regarding PWS Section 5.2.3, does the Government provide a Splicing Trailer for cable splices and repairs?
A. No, the Government does not provide equipment. It is the responsibility of the Contractor.
19. Q. In light of questions yet to be answered, would the Government consider granting a two week extension of the Proposal Due Date?
A. Yes, the Government will extend the proposal receipt due date to 13 Jun 11.
20. Q. There will surely be questions that arise from the Site Visit on May 20th, would the Government consider extending the deadline for submitting questions until after the Pre-Proposal Conference? Yes, the Government has extended the receipt of proposal due date to 13 Jun 11.
21. Q. If we include a Compliance Traceability Matrix with our Proposal, will it be counted towards the total page count?
A. Yes, any information submitted by the Contractor including the matrix is included in the total page count.
CHANGES TO PIRRM PID ITEMS ON REVISED 1 JUN 11 PIRRM REVISION
1. The following PIRRM information on the PID Colum A (Est Purchase Qty) and Column B (Unit) highlighted have been deleted as there is no purchase item on these line items. The new revised PIRRM dated 1 Jun 11 will replace delete the purchase qty and unit.
| 5003 |
| 4-Wire Data Service Unit |
| 5 |
| EA |
| 5004 |
| 4-Wire DX Signalling Unit |
| 5 |
| EA |
| 5005 |
| 2-Wire Channel Unit Card |
| 5 |
| EA |
| 5006 |
| 4-Wire Channel Unit Card |
| 5 |
| EA |
| 5050 |
| DEMARCATION POINT CROSS-CONNECTIONS : (these are always to be included) |
| 5052 |
| 2-Wire Circuit |
| 20 |
| EA |
| 5053 |
| VOIP Programing to Send Stations to the Cisco Call Manager (qty 1 - 49) |
| 10 |
| EA |
| 5054 |
| VOIP Programing to Send Stations to the Cisco Call Manager (qty 50 - 99) |
| 50 |
| EA |
| 5055 |
| VOIP Programing to Send Stations to the Cisco Call Manager (qty 100 & above) |
| 100 |
| EA |
| 5057 |
| POINT TO POINT CROSS CONNECTIONS |
| 10 |
| EA |
| 5059 |
| 4 Wire Circuit |
| 10 |
| EA |
| 6051 |
| Placement of Metallic Cable (up to 50 pair) into Existing Trench |
| 1,000 |
| FT |
| 6052 |
| Placement of Metallic Cable (100 pair) into Existing Trench |
| 1,000 |
| FT |
| 6053 |
| Placement of Metallic Cable (150 pair) into Existing Trench |
| 1,000 |
| FT |
| 6054 |
| Placement of Metallic Cable (200 pair) into Existing Trench |
| 1,000 |
| FT |
| 6055 |
| Placement of Metallic Cable (300 pair) into Existing Trench |
| 4,000 |
| FT |
| 6056 |
| Placement of Metallic Cable (600 pair) into Existing Trench |
| 4,000 |
| FT |
| 6057 |
| Placement of Metallic Cable (1200 pair) into Existing Trench |
| 4,000 |
| FT |
| 6100 |
| Metallic Cable in Existing Conduit: |
| 6101 |
| Pulling Metallic Cable (up to 50 pair) through Existing Conduit |
| 1,000 |
| FT |
| 6102 |
| Pulling Metallic Cable (100 pair) through Existing Conduit |
| 1,000 |
| FT |
| 6103 |
| Pulling Metallic Cable (200 pair) through Existing Conduit |
| 1,000 |
| FT |
| 6104 |
| Pulling Metallic Cable (300 pair) through Existing Conduit |
| 4,000 |
| FT |
| 6105 |
| Pulling Metallic Cable (600 pair) through Existing Conduit |
| 4,000 |
| FT |
| 6106 |
| Pulling Metallic Cable (1200 pair) through Existing Conduit |
| 4,000 |
| FT |
| 6150 |
| FIBER OPTIC CABLE INSTALLATION - Fiber Optic Cable in Existing Trench (Direct Buried) |
| 6151 |
| Placement of Fiber Optic Cable (6-72 Fiber) into Existing Trench |
| 4,000 |
| FT |
| 6200 |
| Fiber Optic Cable in Existing Duct/Innerduct: |
| 6201 |
| Pulling Fiber Optic Cable (6-72 Fiber) through Existing Duct/Innerduct |
| 4,000 |
| FT |
| 6252 |
| Trenching through and restoration of Soft Surfaces, 18" wide, 40" deep [ 2x2 conduit layout] |
| 1,000 |
| FT |
| 6253 |
| Trenching through and restoration of Hard Surfaces, 18" wide, 30" deep [ 1x2 conduit layout] |
| 1,000 |
| FT |
| 6254 |
| Trenching through and restoration of Hard Surfaces, 18" wide, 40" deep [ 2x2 conduit layout] |
| 1,000 |
| FT |
| 6262 |
| Trenching through and restoration of Soft Surfaces, 6" wide, 30" deep [trench only |
| 1,000 |
| FT |
| 6266 |
| Trenching through and restoration of Soft Surfaces, 30" wide, 40" deep [ 2x4 conduit layout, trench only] |
| 1,000 |
| FT |
| 6267 |
| Trenching through and restoration of Hard Surfaces, 6" wide, 30" deep trench only] |
| 1,000 |
| FT |
| 6269 |
| Trenching through and restoration of Hard Surfaces, 18" wide, 30" deep [ 1x2 conduit layout trench only] |
| 1,000 |
| FT |
| 6270 |
| Trenching through and restoration of Hard Surfaces, 18" wide, 30" deep [ trench only] |
| 1,000 |
| FT |
| 6271 |
| Trenching through and restoration of Hard Surfaces, 18" wide, 40" deep [ 2x2 conduit layout, trench only] |
| 1,000 |
| FT |
| 6262 |
| Trenching through and restoration of Soft Surfaces, 6" wide, 30" deep [trench only |
| 1,000 |
| FT |
| 6266 |
| Trenching through and restoration of Soft Surfaces, 30" wide, 40" deep [ 2x4 conduit layout, trench only] |
| 1,000 |
| FT |
| 6267 |
| Trenching through and restoration of Hard Surfaces, 6" wide, 30" deep trench only] |
| 1,000 |
| FT |
| 6269 |
| Trenching through and restoration of Hard Surfaces, 18" wide, 30" deep [ 1x2 conduit layout trench only] |
| 1,000 |
| FT |
| 6270 |
| Trenching through and restoration of Hard Surfaces, 18" wide, 30" deep [ trench only] |
| 1,000 |
| FT |
| 6271 |
| Trenching through and restoration of Hard Surfaces, 18" wide, 40" deep [ 2x2 conduit layout, trench only] |
| 1,000 |
| FT |
| 6272 |
| Trenching through and restoration of Hard Surfaces, 18" wide, 40" deep [Trech only] |
| 1,000 |
| FT |
| 6273 |
| Trenching through and restoration of Hard Surfaces, 18" wide, 40" deep [ 2x2 conduit layout, trench only] |
| 1,000 |
| FT |
| 6274 |
| Cutting through Concrete, 24" wide |
| 1,000 |
| FT |
| 6275 |
| Cutting through Asphalt, 6" wide |
| 1,000 |
| FT |
| 6276 |
| Cutting through Asphalt, 30" wide |
| 1,000 |
| FT |
| 6277 |
| Cutting through Concrete, 6" wide |
| 1,000 |
| FT |
| 6278 |
| Cutting through Concrete, 30" wide |
| 1,000 |
| FT |
| 6401 |
| Bore through or under Hard Surface and Install 4 inch 2-Way Ducts into the Bore, Purchase Schedule 80 conduit under separate PID |
| 1,000 |
| FT |
| 6403 |
| Directional bore through or under Hard Surface and Install 4 inch 1-way duct into the bore, Purchase Schedule 80 conduit under separate PID |
| 50 |
| FT |
| 6404 |
| Directional bore through or under Hard Surface and Install 2 inch 2-way ducts into the bore, ,Purchase Schedule 80 conduit under separate PID |
| 50 |
| FT |
| 6414 |
| Directional bore through or under Hard Surface and Install 4 inch 4-Way Ducts into the Bore, Purchase Schedule 80 conduit under separate PID |
| 50 |
| FT |
| 6406 |
| Core Drill 2" Hole Through 6" - 8" Wall (Concrete) |
| 50 |
| EA |
2. The following blue highlighted changes in the Column F (Unit) have been made to the PIRRM (1 Jun 11).
| 6407 |
| Core Drill 2" Hole Through 6" - 8" Wall (Dry Wall) |
| 50 |
| EA |
| 6408 |
| Core Drill 5" Hole Through 6" - 8" Wall (Concrete) |
| 50 |
| EA |
| 6409 |
| Core Drill 5" Hole Through 6" - 8" Wall (Dry Wall) |
| 50 |
| EA |
| 6410 |
| Core Drill 2" Hole Through 6" - 8" Floor (Hard Surface) |
| 50 |
| EA |
| 6411 |
| Core Drill 5" Hole Through 6" - 8" Floor (Hard Surface) |
| 50 |
| EA |
| 6412 |
| Firestop 1" Diameter |
| 50 |
| EA |
| 6413 |
| Firestop 2" Diameter |
| 50 |
| EA |
| 6414 |
| Firestop 3" Diameter |
| 50 |
| EA |
| 8002 |
| SITE SURVEYS for installation of CPE or inside cabling (PWS 1.4.1.4.1) |
| 8003 |
| Global Positioning Updates (Appendix 5.7) |
| 8004 |
| Manhole PMIs (PWS 1.4.4a) |
| 8005 |
| Terminal PMIs (PWS 1.4.4b) |
| 8100 |
| GPS Data Collection Service |
| 8103 |
| Manhole, Handhole, Pedestal, or Splice (EA = price per data point collected) |
| 8150 |
| CYBERSPACE VISUALIZATION COMPONENT(CVC) |
| 8151 |
| Convert Legacy CSIR Cable Diagram Drawing or 3rd Party As-Built Drawing data to CVC (EA = price per drawing converted) |
| 8152 |
| Convert Legacy CSIR Manhole Racking Diagram Drawing or 3rd Party Manhole Racking Diagram As-Built Drawing MH data of Simple Complexity to CVC. (EA = price per each MH converted) |
| 8153 |
| Convert Legacy CSIR Manhole Racking Diagram Drawing MH or 3rd Party Manhole Racking Diagram As-Built Drawing data of Medium Complexity to CVC. (EA = price per each MH converted) |
| 8154 |
| Convert Legacy CSIR Manhole Racking Diagram Drawing MH or 3rd Party Manhole Racking Diagram As-Built Drawing data of Major Complexity to CVC. (EA = price per each MH converted) |
| 8155 |
| Convert Legacy CSIR Cable Vault Drawing data to CVC (EA = price per each Cable Vault converted) |
| 8156 |
| Convert CITS CFLD EXCEL Spreadsheet data for a comm path segment to CVC (FT = price per each linear foot converted.) |
Page | 8