This document is a Preventive Maintenance (PM) inspection report for Constant Current Regulators (CCRs) located at an electrical vault/substation at coordinates 37.079141, -76.355321 in Virginia, dated April 24, 2026. The report documents maintenance and testing activities performed on airfield lighting equipment, specifically CCRs used for runway approach lighting systems.
The inspection covers 27 CCR units across multiple circuits including PAPI (Precision Approach Path Indicator), runway, approach, and taxiway lighting systems. Key maintenance activities completed include CCR calibration, cleaning, local and remote operational testing, and feedback verification. However, output waveforms were not analyzed and hotspot checks were not performed on the units. The inspection identified firmware versions across the units: CCR Firmware 38A.04, ACE Firmware 28A.07, and IRMS Firmware 32A.04 (with some variations). Detailed measurement data in three appendices provide specific current outputs (I-out) at various step levels (B1 through B5/B100), voltage outputs (V-out), and volt-ampere outputs (VA-out) for each CCR unit, including spare units and empty cells. Notes, conclusions, and recommendations are referenced in an accompanying trip report. Several spare units showed zero output readings, indicating they are not currently operational or in inventory.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CCR PMA - Measurements and Data collection
Date 24/04/26 Page 1 / 1
1. Site information
Electrical Vault/substation name Vault 1
Location [{coordinates=37.079141;-76.355321;-32.600002;ellipsoid;42.5, alt=-32.600002, accuracy=42.5, locationPickerIndex=0, lat=37.079141, long=-76.355321, altRefSys=ellipsoid}]
2. CCRs data
CCRs measurements (See Appendix A)
3. CCR PM
CCR Calibrated Yes No
Output waveforms analyzed Yes No
CCR checked for hotspots Yes No
CCR Cleaned Yes No
Local Operational test Yes No
Remote Operational Test Yes No
Feedbacks verified Yes No
4. General Observations
Notes and observations See trip report
Conclusions and recommendations See trip report
Recommended Spare parts See trip report
ADB_Safegate - - - -
Appendix A - CCRs measurements Date 24/04/26 Page 1 / 3
CCR/Circu it Name
Model Serial Number
Number of Steps
B1 I-out B2 I-out B3/B10 I-out
B4/B30 I-out
B5/B100 I-out
B5/B100 V-out
B5/B100 VA-out
CCR
Firmware
ACE
Firmware
IRMS
Firmware
Notes
PAPI 26 PSF6604/
20180508 00013
5 2.8 3.4 4.1 5.2 6.6 330 2100 38A.04 28A.07 32A.04
Runway R2
PSF6630/
20180508 00004
5 2.8 3.4 4.1 5.2 6.6 2300 15000 38A.04 28A.07 32A.04
Approach 26B
PSF6620/
20180508 00008
5 2.8 3.4 4.1 5.2 6.6 2300 15000 38A.04 28A.07 32A.04
Approach 26A
PSF6620/
20180508 00009
5 2.8 3.4 4.1 5.2 6.6 2000 13000 38A.04 28A.07 32A.04
Approach 26C
PSF6620/
20180508 00006
5 2.8 3.4 4.1 5.2 6.6 2000 13000 38A.04 28A.07 32A.04
Approach 26D
PSF6620/
20180508 00007
5 2.8 3.4 4.1 5.2 6.6 2000 13000 38A.04 28A.07 32A.04
TWY A
East, M, D
PSF6607/
20180508 00012
3 4.8 5.5 6.6 0 0 370 2440 38A.04 28A.07 32A.04
TWY E, F PSF6607/
20180606 00199
3 4.8 5.5 6.6 0 0 170 1140 38A.04 28A.07 32A.04
Spare 2 PSF6620/
20180508 00010
3 4.8 5.5 6.6 0 0 0 0 38A.04 28A.07 32A.04
Spare 1 PSF6630/
20180508 00005
5 2.8 3.4 4.1 5.2 6.6 0 0 38A.04 28A.07 32A.04
Runway R1
PSF6630/
20180606 00191
5 2.8 3.4 4.1 5.2 6.6 2500 16300 38A.04 28A.07 32A.04
Appendix B - CCRs measurements Date 24/04/26 Page 2 / 3 it Name
Model Serial Number
Number of Steps
B1 I-out B2 I-out B3/B10 I-out
B4/B30 I-out
B5/B100 I-out
B5/B100 V-out
B5/B100 VA-out
CCR
Firmware
ACE
Firmware
IRMS
Firmware
Notes
PAPI 08 PSF6604/
20180606 00200
5 2.8 3.4 4.1 5.2 6.6 350 2300 38A.04 28A.07 32A.04
Approach 08 A
PSSF6620
/535
20200318 00015
5 2.8 3.4 4.1 5.2 6.6 1800 12200 38A.04 28A.07 32A.04
Approach 08 B
PSF6630/
20180606 00192
5 2.8 3.4 4.1 5.2 6.6 3000 19000 38A.04 28A.07 32A.04
Approach 08 C
PSSF6620
/535
20200318 00014
5 2.8 3.4 4.1 5.2 6.6 2400 16100 38A.04 28A.07 32A.04
Approach 08 D
PSSF6620
/535
20200318 00012
5 2.8 3.4 4.1 5.2 6.6 2000 12900 38A.04 28A.07 32A.04
Taxiway A West, H
PSF6607/
20180522 00921
3 4.8 5.5 6.6 0 0 450 2900 38A.04 28A.07 32A.04
Taxiway B, C
PSF6607/
20180522 00922
3 4.8 5.5 6.6 0 0 200 1400 38A.04 28A.07 32A.04
Taxiway K PSF6607/
20180522 00923
3 4.8 5.5 6.6 0 0 190 1200 38A.04 28A.07 32A.04
Spare 3 NA NA 1 0 0 0 0 0 0 0 38A.04 28A.07 NA Empty Cell
Empty C-
PSF2020/
20180606 00195
5 8.5 10.3 12.4 15.8 20.0 0 0 NA 28A.07 32A.04
Empty C-
PSF2020/
20180606 00193
5 0 0 0 0 0 0 0 38A.04 28A.07 32A.04
Appendix C - CCRs measurements Date 24/04/26 Page 3 / 3 it Name
Model Serial Number
Number of Steps
B1 I-out B2 I-out B3/B10 I-out
B4/B30 I-out
B5/B100 I-out
B5/B100 V-out
B5/B100 VA-out
CCR
Firmware
ACE
Firmware
IRMS
Firmware
Notes
Spare 6 PSF6620/
20180508 00011
3 0 0 0 0 0 0 0 38A.04 28A.07 32A.04
Empty C-
PSF2020/
20180606 00196
5 0 0 0 0 0 0 0 38A.04 28A.07 32A.04
Spare 4 PSF6620/
20180606 00197
3 0 0 0 0 0 0 0 38A.04 28A.07 32A.04
Spare 5 PSSF6620 /535
20200318 00013
5 0 0 0 0 0 0 0 38A.04 28A.07 32A.04